3-8. Exhibit J.6 Drawings.pdf

PDF 8 MB Posted

Attached to
Pack Unit - Replace Roof Multiple Bldgs.
Solicitation number
696-FD-27-P002
Issued by
Gillespie County, Texas

About this file

This is a set of architectural drawings and project specifications for a roofing replacement project at the Wallace Pack Unit of the Texas Department of Criminal Justice (TDCJ) located at 2400 Wallace Pack Road, Navasota, Texas 77868. The project involves replacing approximately 184,000 square feet of roofing across multiple buildings and structures, including Wings A through E, Halls A through H, the gymnasium, and administrative facilities. The scope of work includes demolition of existing standing seam metal roof panel systems, installation of new 24-gauge trapezoidal metal roof panel systems with structural insulation (R-30 value), replacement of wall panels and soffit systems, structural repairs to damaged purlins and bracing, mechanical equipment replacement, and site grading improvements. The project also encompasses a retrofit metal roofing system for Wing E using a sub-purlin installation method. Construction specifications reference the 2021 International Building Code, International Existing Building Code, International Fire Code, and applicable Navasota city codes. The drawings indicate this is an "Issued for Proposal" package, suggesting active solicitation of bids from qualified contractors.

The project requires contractors to obtain all necessary permits, inspections, and certifications with associated costs included in bid prices. Contractors must comply with safety requirements including OSHA trenching guidelines, provide temporary construction safety fencing, coordinate with utility companies 48 hours prior to work, maintain interior building temperatures between 68 to 78 degrees Fahrenheit during construction, and implement dust control and storm water pollution prevention measures. The specification emphasizes the occupied nature of the facility with offenders and staff present during construction phases, requiring coordination of utility shutdowns with a minimum 72-hour notice. Salvageable existing items must be properly stored, refurbished to full operational condition, and thoroughly cleaned before reinstallation. The project is classified as IBC Section 308.4 (Institutional Group I-3) with Type II-B construction for new components. No pricing information, set-asides, incumbents, award dates, or contract term details are specified in this architectural drawings exhibit.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P.YA MAY 17, 2012

N0APPROVEDM

T0NE,

D W. S

TEXAS BOARD

EXAMINERS

TO PRACTICE

ARCHITECTURE

ARCHITECTURAL

R

E.

OF

BY THE

WALLACE PACK UNIT

REPLACE ROOF - MULTIPLE BLDGS.

MWR# 02618010

TEXAS DEPARTMENT OF CRIMINAL JUSTICE

CS

amtech t 713.266.4829 f 713.266.4977 solutions, inc.

VICINITY MAP- 2400 WALLACE PACK ROAD, NAVASOTA, TEXAS

NOT TO SCALE

AERIAL VIEW OF SITE PLAN

NOT TO SCALE

COVER SHEET

NORTH

HOUSTON, TEXAS 77094

16300 KATY FREE WAY, SUITE 230

PROJECT LOCATION: 2400 WALLACE PACK ROAD

GRIMES COUNTY

NAVASOTA, TEXAS 77868

APPLICABLE CODES FOR CITY OF NAVASOTA, TEXAS:

2021 INTERNATIONAL BUILDING CODE (IBC)

2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC)

2021 INTERNATIONAL FIRE CODE (IFC)

2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)

2021 INTERNATIONAL MECHANICAL CODE (IMC)

2021 INTERNATIONAL PLUMBING CODE (IPC)

2020 NFPA 70, 2020 NATIONAL ELECTRIC CODE (NEC) WITH AMENDMENTS

OCCUPANCY CLASSIFICATION AND USE:

IBC SECTION 308.4: INSTITUTIONAL GROUP I-3, EXISTING BUILDINGS REMAIN UNCHANGED

GENERAL BUILDING HEIGHTS AND AREAS:

IBC SECTION 504.1: VARIES BY BUILDING, EXISTING BUILDINGS REMAIN UNCHANGED

CONSTRUCTION TYPE:

IBC TABLE 601: TYPE II-B NEW CONSTRUCTION, OR EXISTING BUILDINGS REMAIN UNCHANGED

FIRE PROTECTION AND LIFE SAFETY SYSTEMS:

IBC CHAPTER 7: EXISTING BUILDINGS REMAIN UNCHANGED

FIRE RESISTANCE REQUIREMENTS:

IBC TABLE 601: EXISTING BUILDINGS REMAIN UNCHANGED

MEANS OF EGRESS:

IBC SECTION 1001.2: EXISTING BUILDINGS REMAIN UNCHANGED

ACCESSIBILITY:

IBC SECTION 1102.1: EXISTING BUILDINGS REMAIN UNCHANGED

ENERGY EFFICIENCY: EXISTING BUILDINGS REMAIN UNCHANGED

IECC FIGURE C301.1: CLIMATE ZONE 2A* (WARM HUMID COUNTY)

ENVELOPE REQUIREMENTS:

IECC TABLE C402.1.3: EXISTING BUILDINGS REMAIN UNCHANGED

IECC TABLE C402.1.4: EXISTING BUILDINGS REMAIN UNCHANGED

EXTERIOR WALLS:

IBC CHAPTER 14: NEW CONSTRUCTION, OR EXISTING BUILDINGS REMAIN UNCHANGED

ROOF ASSEMBLIES:

IBC CHAPTER 15: NEW CONSTRUCTION, OR EXISTING BUILDINGS REMAIN UNCHANGED

STRUCTURAL DESIGN:

IBC SECTION 1609 WIND LOADS: EXISTING BUILDINGS REMAIN UNCHANGED

GENERAL NOTES:

1. CONTRACTOR SHALL COMPLY WITH ALL CURRENT CITY NAVASOTA, TEXAS CODES, STANDARD, AND PRACTICES

2. CONTRACTOR SHALL OBTAIN ALL PERMITS AND INSPECTIONS, AND INCLUDE THE COST OF ALL APPLICABLE PERMITS, INSPECTIONS, AND NECESSARY FEES IN THEIR BID PRICE

3. CONTRACTOR SHALL NOTIFY ALL APPROPRIATE UTILITY COMPANIES, INCLUDING BUT NOT LIMITED TO Texas811, 48 HOURS PRIOR TO CONSTRUCTION TO LOCATE EXISTING UTILITIES AND UNDERGROUND IRRIGATION SYSTEMS

4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO LOCATE AND PROTECT ANY EXISTING UTILITIES (BOTH ABOVE AND BELOW GROUND), COMMUNICATION CABLING, EXISTING IRRIGATION SYSTEMS, EXISTING TREES, EXISTING GRASS, EXISTING

CANOPIES / PLAY STRUCTURES, ETC. WHICH ARE TO REMAIN

5. CONTRACTOR SHALL FOLLOW CURRENT OSHA OPEN TRENCH SAFETY GUIDELINES FOR ANY TRENCHING ACTIVITIES

6. CONTRACTOR SHALL PROVIDE TEMPORARY CONSTRUCTION SAFETY FENCING DURING CONSTRUCTION ACTIVITIES

7. CONTRACTOR SHALL PROVIDE NECESSARY SAFETY PROCEDURES DURING CONSTRUCTION ACTIVITIES AS BUILDINGS WILL, OR MAY BE OCCUPIED BY OFFENDERS AND STAFF DURING VARIOUS STAGES OF CONSTRUCTION

8. CONTRACTOR SHALL FIELD VERIFY AND IDENTIFY ALL EXISTING CONDITIONS OF EXISTING FACILITIES, INCLUDING BUT NOT LIMITED TO BUILDING STRUCTURE, AND EXISTING UTILITY LOCATIONS, SIZES, AND QUANTITIES PRIOR TO PROCEEDING

WITH CONSTRUCTION

9. CONTRACTOR SHALL PROVIDE DUST CONTROL WHEN CONSTRUCTION AREA SURFACE SOIL IS LOOSE AND DRY AND THE WIND IS BLOWING ENOUGH TO CARRY LOOSE SOIL. CONTRACTOR SHALL SPRINKLE ANY DISTURBED SOIL WITH WATER

UNTIL THE SURFACE IS WET ENOUGH TO CONTROL DUST

10. CONTRACTOR SHALL PROVIDE DUST CONTROL MEASURES FOR ALL INTERIOR WORK

11. CONTRACTOR SHALL PROVIDE DUST CONTROL UNTIL SEEDING, OR SODDING HAS PROGRESSED ENOUGH TO PREVENT WIND EROSION

12. STORM WATER POLLUTION CONTROL / SEDIMENT CONTROL SHALL BE PROVIDED AND MAINTAINED BY THE CONTRACTOR IN ACCORDANCE WITH CITY OF NAVASOTA, TEXAS STANDARDS, REQUIREMENTS, AND REGULATIONS

13. CONTRACTOR SHALL NOTIFY THE OWNER AND COORDINATE ANY UTILITY SHUT DOWNS WITH THE OWNER A MINIMUM OF 72 HOURS PRIOR TO ANY UTILITY SHUT DOWN. UTILITY SHUTDOWNS SHALL INCLUDE ELECTRICAL, PLUMBING, AND

MECHANICAL EQUIPMENT / DEVICES.

14. CONTRACTOR SHALL NOT LET ANY BUILDING, OR PORTION OF A BUILDING TO BE WITHOUT CONDITIONED AIR FOR MORE THAN 72 HOURS, AND SHALL MAINTAIN INTERIOR BUILDING TEMPERATURES BETWEEN 68°F - 78°F DURING ALL STAGES OF

CONSTRUCTION

15. CONTRACTOR IS RESPONSIBLE TO MAINTAIN ALL BUILDINGS IN-THE- DRY DURING ALL STAGES OF CONSTRUCTION

16. CONTRACTOR IS RESPONSIBLE TO PROVIDE JOB SITE SECURITY FOR THEIR CONSTRUCTION MATERIALS AND EQUIPMENT

17. CONTRACTOR IS RESPONSIBLE TO PROVIDE NECESSARY MEANS AND METHODS TO MAINTAIN SECURE BUILDINGS DURING REMOVAL OF EXISTING EXTERIOR WALL AND ROOF COMPONENTS WHICH MIGHT ALLOW UNAUTHORIZED BUILDING ENTRY

18. ALL EXISTING ITEMS TO BE SALVAGED FOR RE-INSTALLATION, SHALL BE PROPERLY STORED, PROTECTED, AND CATALOGED FOR RE-INSTALLATION

19. ALL EXISTING ITEMS TO BE SALVAGED FOR RE-INSTALLATION, SHALL BE REFURBISHED TO A FULL, COMPLETE, AND OPERATIONAL CONDITION AFTER RE-INSTALLATION

20. ALL EXISTING ITEMS TO BE SALVAGED FOR RE-INSTALLATION, SHALL BE THOROUGHLY CLEANED PRIOR TO RE-INSTALLATION, AND BEFORE RE-INSTALLATION

21. CONTRACTOR SHALL PROVIDE ALL NECESSARY SHORING AND SAFETY MEASURES REQUIRED DURING CONSTRUCTION

ISSUED FOR PROPOSAL

CS COVER SHEET

OSP OVERALL SITE PLAN

C1 EXISTING ELEVATION PLAN

C2 PROPOSED ELEVATION PLAN

S1.0 STRUCTURAL REPAIR PLAN

S2.0 STRUCTURAL REPAIR PLAN

S2.1 STRUCTURAL REPAIR PLAN

S2.2 STRUCTURAL FRAMING REPAIR DETAILS

S3.0 STRUCTURAL REPAIR PLAN

RD1 ROOF PLAN WING C, HALL C, WING D, AND HALL D - DEMOLITION

RD2 ROOF PLAN WING A, HALL A, WING B, AND HALL B - DEMOLITION

RD3 ROOF PLAN G, HALL G, G2, H, AND HALL H - DEMOLITION

RD4 ROOF PLAN GYM, J, HALL J, AND J2 - DEMOLITION

RD5 ROOF PLAN WING E-E14 - DEMOLITION

R1 ROOF PLAN WING C, HALL C, WING D, AND HALL D - CONSTRUCTION

R2 ROOF PLAN WING A, HALL A, WING B, AND HALL B - CONSTRUCTION

R3 ROOF PLAN G, HALL G, G2, H, AND HALL H - CONSTRUCTION

R4 ROOF PLAN GYM, J, HALL J, AND J2 - CONSTRUCTION

R5 ROOF PLAN WING E-E14 - CONSTRUCTION

WD1 ELEVATIONS - DEMOLITION

W1 ELEVATIONS - CONSTRUCTION

D1 ROOF DETAILS

D2 ROOF DETAILS

D3 ROOF DETAILS

D4 ROOF DETAILS

D5 WALL DETAILS

MPD-1 MECHANICAL AND PLUMBING DEMO PLAN

MPD-2 MECHANICAL AND PLUMBING DEMO PLAN

MPD-3 MECHANICAL AND PLUMBING DEMO PLAN

MPD-4 MECHANICAL AND PLUMBING DEMO PLAN

MPD-5 MECHANICAL AND PLUMBING DEMO PLAN

MP-1 MECHANICAL AND PLUMBING PLAN

MP-2 MECHANICAL AND PLUMBING PLAN

MP-3 MECHANICAL AND PLUMBING PLAN

MP-4 MECHANICAL AND PLUMBING PLAN

MP-5 MECHANICAL AND PLUMBING PLAN

MP-6 MECHANICAL DETAILS

ED-1 ELECTRICAL DEMOLITION PLAN

ED-2 ELECTRICAL DEMOLITION PLAN

ED-3 ELECTRICAL DEMOLITION PLAN

ED-4 ELECTRICAL DEMOLITION PLAN

ED-5 ELECTRICAL DEMOLITION PLAN

E-1 ELECTRICAL PLAN

E-2 ELECTRICAL PLAN

E-3 ELECTRICAL PLAN

E-4 ELECTRICAL PLAN

E-5 ELECTRICAL PLAN

TABLE OF CONTENTS

BRAND OR MANUFACTURE'S REFERENCES AREA DESCRIPTIVE

ONLY, AND INDICATE TYPE AND QUALITY TO BE PROVIDED. ALL

REFERENCES TO BRAND OR MANUFACTURER NAMES SHALL BE

INTERPRETED TO INCLUDED THE LANGUAGE "OR A/E

APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING

SPECIFICATIONS WILL BE CONSIDERED. IRRESPECTIVE OF THE

LANGUAGE "OR A/E APPROVED EQUAL" APPEARING IN

CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.

09/24/2025

J2

P

M

M2

X

W

Y Z

AA G

G2

Q

R

B

A

N

N1

T

U

S

J

M3

SB

DS

SB

DS

SB

DS DUCT

EF EF EF EF

SP

EF

V V V V

V V V V V V

EF

V

EF

V

SP

V V V

V

SB

DS

SB

DS SB

DS

SL SL

SL SL

SC

SB

DS

WALL LIGHT

PP

PP

LADDER

SC

SB

DS

SL

SL

GUTTER

GUTTER

GUTTER

SUPPORT

RTU

PPGUTTER

GUTTER

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

WING D

WING C

WING B

WING A

RESTRICTION

HOUSING

ADMINISTRATION

FOOD

SERVICE

INFIRMARY

EDUCATION

LAUNDRY

GYM

N.I.C.

N.I.C.

N.I.C.

BB

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

WING E

HALL

SL SL

SL SL

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

E1

E2 E3

E4

E5 E6

E7

E14

E13

E12

E11

E10 E9

E8 V

V

SA

SA

SA

SA

SA

SA

ANT/EP

V

V

ANT/EP

SP

SP

SP

SP

V

V

V

V

V V

SP

SP

V

V

ACCU ACCU

PP

SP

SP

SP

SP

V

V

V

V

V

V

SP

SP

EF

V

V

V

V

EF

V

V

V

SP

SP

SP

V

EF

PP

V

V

V

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

HALL H

HALL G

HALL A

HALL B

HALL C

HALL D

EF

EF

EF

EF

EF

EF

SP

SP

SP

SP

SP

EF

V

V V

SUPPORT

CURB RTU

SF

SF

EF

EF

RTU

WALL LIGHT

SD

ANT/EP

EF

DS

DS

DS

EF EF EF

EF EF EF

SP SP

EF EF

EF EF EF

EF EF EF

RTU

EF

EF

EF

EFEF EFEF EF

EF EF EF EF

SP

EF EF

SP

EF EF EF EF EF EF

EF EF EF EF EF EF

EF

SP SP

EF

EF

EF

EF EF EF EF EF

EF EF EF EF EF

RTU

EF

SP SP

EF

HSHS

ANT/EP

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

SB

DS

SB

DS SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SUPPORT

CURB

SUPPORT

CURB

SUPPORT

CURB

SUPPORT

CURB

DS

DS DS

DS DS

DS DS

DS DS

SB

SB SB

SB SB

SB SB

SBSB

ANT/EP

WALL LIGHTWALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHTWALL LIGHT

SB

DS

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

GUTTER

GUTTER

GUTTER

GUTTER

GUTTER

SPEAKER

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

WALL LIGHTWALL LIGHT

D1 N.I.C.

SL

SL

SL

SL

SL

SL

SL

SL

SL

SL

SL

SL

SL

SL

SL

SL

SL

SL

SL

SL

J

SP

EF

V

EF

V

V

AB

V

V

EF

AB

V

SP

PPPP

PPPP

EF

AB

PPPP

PPPP

V

PP

PP

PP

PP

PP

PP

DS

AB

PP

PP

PP

PP

PP

PP

DS

V V

V

EFSP

V

V

SCSB

DS

DS SB

DS

SB

DS

SB

DS

SB

DS

SL SL SL SL

SL SLSL

SLSL

V

SB

DS

W W

W W

W W

W

W W

W

SB

DS SB

DS

SL

SL

SUPPORT

CURBSB

DS

GUTTER

GUTTER

SB

DS

SB

DS

SB

DS

SB

DS

H V

RTU

SD

AB

PP

EF

CD SP

RTU

EF

EF

EF

PP

PP PP

SP

PP

PP

SF

PP

PP HS

RTU

PP

SP

SP

PP

PP

PP

SF

EFPP

SP

PP

EF

RTU

PP

PP

EFSP PP

SF

SP V

EF

PP

PP

AB

EF

RTU

PP

PP

SF

PP

SD

PP

PP

RTU

EFRTU

SP

PPPP

EF

RTU

RTU

EF

PP

PP

EF

SP

V

PP

PP

PP

PP

PP

EF

PP

RTU

PP

PP

SF

PPPP PP

PP

VSF SP

EF

PPPP

EF

PP

EF

PPPP SP

EF

SP

EF

SP

V V

EF VANT

GUTTERGUTTER

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

CURB

EF

DUCT

DUCT DUCT

DUCT

DUCT

DUCT

DUCT

DUCT

DUCT DUCT

DUCT

DUCT

DUCTDUCT

DUCT

DUCT

DUCT

GUTTER

STAGING

AREA

OSP

P.YA MAY 17, 2012

N0APPROVEDM

T0NE,

D W. S

TEXAS BOARD

EXAMINERS

TO PRACTICE

ARCHITECTURE

ARCHITECTURAL

R

E.

OF

BY THE

a m te ch so lu tio ns , i nc

OVERALL SITE PLAN

OSP

OVERALL SITE PLAN

NOT TO SCALE

NORTH

KA

TY

F

R

EE

W

AY

, S U

IT

E

#2

H O

U

ST

O N

, T

EX

AS

t

3.

6.

NOT IN CONTRACT (N.I.C.)

LEGEND

TE

XA

S D

EP

AR

TM

EN

T O

F C

R

IM

IN

AL

J U

ST

IC

E W

AL

LA

C E

PA

C

K U

N

IT

R

EP

LA

C

E R

O O

F

- M

U

LT

IP

LE

B

LD

G S.

N

AV

AS

O

TA

, T

EX

AS

AS NOTED

C.C.G.

J.R.,D.V, R.S.

09/24/2025

STAGING AREA

STAGING AREA

NOT TO SCALE

NORTH

EXISTING WALL AND SOFFIT MATERIALS

WINGS A, B, C, D – METAL WALL AND SOFFIT PANELS

· EXISTING INSULATED METAL WALL PANELS AND NON-INSULATED

METAL SOFFIT PANELS MECHANICALLY ATTACHED (OVER)

· EXISTING METAL BUILDING FRAMING

HALLS A, B, C, D – METAL WALL AND SOFFIT PANELS

· EXISTING INSULATED METAL WALL PANELS AND NON-INSULATED

METAL SOFFIT PANELS MECHANICALLY ATTACHED (OVER)

· EXISTING METAL BUILDING FRAMING

WING E, AREAS E1, E2, E3, E4, E5, E6, E7, E8, E9, E10, E11, E12, E13, AND E14 –

SEALANT REPAIRS

· EXISTING INSULATED METAL WALL PANELS AND NON-INSULATED

METAL SOFFIT PANELS MECHANICALLY ATTACHED (OVER)

· EXISTING METAL BUILDING FRAMING

AREA G, AREA G2, AREA H, HALL G, HALL H – SEALANT REPAIRS

· EXISTING INSULATED METAL WALL PANELS AND NON-INSULATED

METAL SOFFIT PANELS MECHANICALLY ATTACHED (OVER)

· EXISTING METAL BUILDING FRAMING

AREA J, AREA J2, GYM, HALL J – SEALANT REPAIRS

· EXISTING INSULATED METAL WALL PANELS AND NON-INSULATED

METAL SOFFIT PANELS MECHANICALLY ATTACHED (OVER)

· EXISTING METAL BUILDING FRAMING

STRUCTURAL REPAIRS

ALL BUILDINGS, WINGS, AND HALLS (EXISTING PRE-ENGINEERED METAL

BUILDING STRUCTURES)

· REPLACE DAMAGED EXISTING PURLINS AND DAMAGED SECONDARY

BRACING WITH NEW PURLINS AND NEW SECONDARY BRACING AT

SELECT LOCATIONS AS SHOWN ON STRUCTURAL DRAWINGS

· REPLACE DAMAGED EXISTING WALL GIRTS AND DAMAGED SECONDARY

BRACING WITH NEW WALL GIRTS AND NEW SECONDARY BRACING AT

SELECT LOCATIONS AS SHOWN ON STRUCTURAL DRAWINGS

· REPLACE EXISTING CABLE BRACING AS SHOWN ON STRUCTURAL

DRAWINGS

NEW METAL ROOF PANEL SYSTEM

WINGS A, B, C, D, ROOF AREAS G, H, AND J, AND GYM – TRAP-TEE

TRAPEZOIDAL NEW METAL ROOF PANEL SYSTEM (GABLE ROOF SLOPE)

· REPLACE EXISTING COATED STANDING SEAM METAL ROOF PANEL

SYSTEM WITH NEW 24 GAUGE, 24” WIDE, 2-3/4” TALL TRAP-TEE

TRAPEZOIDAL METAL ROOF PANEL SYSTEM INCLUDING BUT NOT

LIMITED TO CLIPS, FASTENERS, FULLY WELDED MECHANICAL CURBS,

ROOF FLASHINGS, PRE-FINISHED METAL GUTTERS AND DOWNSPOUTS,

AND ROOF MOUNTED WALKWAY SYSTEM, MECHANICALLY ATTACHED

(OVER)

· SELF-ADHERED UNDERLAYMENT (OVER)

· 4” THICK STRUCTURAL INSULATION WITH TAPED SHIP-LAP JOINTS,

R-VALUE = R-30, MECHANICALLY ATTACHED (OVER)

· EXISTING METAL BUILDING FRAMING

· INSTALL WALKWAY SYSTEM

ROOF AREAS G2, HALLS A, B, C, D, G, H, J, AND J2 – TRAP-TEE TRAPEZOIDAL

NEW METAL ROOF PANEL SYSTEM (SINGLE ROOF SLOPE)

· REPLACE EXISTING COATED STANDING SEAM METAL ROOF PANEL

SYSTEM WITH NEW 24 GAUGE, 24” WIDE, 2-3/4” TALL TRAP-TEE

TRAPEZOIDAL METAL ROOF PANEL SYSTEM INCLUDING BUT NOT

LIMITED TO CLIPS, FASTENERS, FULLY WELDED MECHANICAL CURBS,

ROOF FLASHINGS, PRE-FINISHED METAL GUTTERS AND DOWNSPOUTS,

AND ROOF MOUNTED WALKWAY SYSTEM, MECHANICALLY ATTACHED

(OVER)

· SELF-ADHERED UNDERLAYMENT (OVER)

· 4” THICK STRUCTURAL INSULATION WITH TAPED SHIP-LAP JOINTS,

R-VALUE = R-30, MECHANICALLY ATTACHED (OVER)

· EXISTING METAL BUILDING FRAMING

· INSTALL WALKWAY SYSTEM

WING E – 238T RETROFIT METAL ROOF PANEL SYSTEM (GABLE ROOF

SLOPE)

· NEW 24 GAUGE, 24” WIDE 238T RETROFIT METAL ROOF PANEL SYSTEM

INCLUDING BUT NOT LIMITED TO CLIPS, FASTENERS, FULLY WELDED

MECHANICAL CURBS, ROOF FLASHINGS, PRE-FINISHED METAL

GUTTERS AND DOWNSPOUTS, AND ROOF MOUNTED WALKWAY SYSTEM,

MECHANICALLY ATTACHED (OVER)

· SELF-ADHERED UNDERLAYMENT (OVER)

· 4” THICK STRUCTURAL INSULATION WITH TAPED SHIP-LAP JOINTS,

R-VALUE = R-30, MECHANICALLY ATTACHED (OVER)

· RETROFIT SUB-PURLIN SYSTEM (ROOF HUGGER) (OVER)

· EXISTING COATED TRAPEZOIDAL METAL ROOF PANEL SYSTEM,

CLEANED AND PROPERLY PREPARED FOR INSTALLATION OF NEW

METAL ROOFING SYSTEM COMPONENTS (OVER)

· EXISTING METAL BUILDING FRAMING

· INSTALL WALKWAY SYSTEM

ROOF AREAS E1, E2, E3, E4, E5, E6, E7, E8, E9, E10, E11, E12, E13, AND E14 –

238T RETROFIT METAL ROOF SYSTEM (SINGLE ROOF SLOPE)

· NEW 24 GAUGE, 24” WIDE 238T RETROFIT METAL ROOF PANEL SYSTEM

INCLUDING BUT NOT LIMITED TO CLIPS, FASTENERS, ROOF FLASHINGS,

PRE-FINISHED METAL GUTTERS AND DOWNSPOUTS, MECHANICALLY

ATTACHED (OVER)

· SELF-ADHERED UNDERLAYMENT (OVER)

· 4” THICK STRUCTURAL INSULATION WITH TAPED SHIP-LAP JOINTS,

R-VALUE = R-30, MECHANICALLY ATTACHED (OVER)

· RETROFIT SUB-PURLIN SYSTEM (ROOF HUGGER) (OVER)

· EXISTING COATED TRAPEZOIDAL METAL ROOF PANEL SYSTEM,

CLEANED AND PROPERLY PREPARED FOR INSTALLATION OF NEW

METAL ROOFING SYSTEM COMPONENTS (OVER)

· EXISTING METAL BUILDING FRAMING

NEW METAL WALL PANEL SYSTEM

ALL BUILDINGS, WINGS, AND HALLS (EXISTING PRE-ENGINEERED METAL

BUILDING STRUCTURES)

· REPLACE EXISTING INSULATED METAL WALL PANEL SYSTEM WITH NEW

24 GAUGE, 12” WIDE, 1 1/2” TALL INVERTED PLANK PROFILE METAL WALL

PANELS, AND EXISTING METAL SOFFIT PANEL SYSTEM WITH NEW 24

GAUGE, 12” WIDE, 1 1/2” TALL FLAT PROFILE METAL SOFFIT PANELS,

MECHANICALLY ATTACHED (OVER)

· SELF-ADHERED UNDERLAYMENT (OVER)

· 2 1/2” THICK STRUCTURAL INSULATION (AT EXTERIOR WALLS, SOFFIT

DOES NOT RECEIVE INSULATION), WITH TAPED TONGUE AND GROOVE

JOINTS, R-VALUE = R-18.75 PLUS WALL PANEL AIR SPACE R=0.87 FOR

TOTAL WALL R=19.62, MECHANICALLY ATTACHED (OVER)

· EXISTING METAL BUILDING FRAMING

MECHANICAL EQUIPMENT REPLACEMENT

ALL BUILDINGS, WINGS, AND HALLS (EXISTING PRE-ENGINEERED METAL

BUILDING STRUCTURES)

· REMOVE OR REPLACE EXISTING MECHANICAL EQUIPMENT AND

EXTERIOR LIGHT FIXTURES AT VARIOUS LOCATIONS AS SHOWN ON THE

MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS

· COORDINATE MECHANICAL EQUIPMENT REPLACEMENT WITH ROOFING

REPLACEMENT TO PREVENT WATER INTRUSION INTO INTERIOR SPACES

· EXTEND EXISTING MECHANICAL, ELECTRICAL, AND PLUMBING ROOF

PENETRATIONS AS REQUIRED TO ACCOMMODATE THICKNESSES AND

HEIGHTS OF NEW ROOFING SYSTEM AND AS SHOWN ON MECHANICAL,

ELECTRICAL, AND PLUMBING DRAWINGS

GENERAL SCOPE OF WORK:

EXISTING ROOF MATERIALS

WINGS A, B, C, D, ROOF AREAS G, H, AND J, AND GYM – STANDING SEAM

METAL ROOF PANEL SYSTEM (GABLE ROOF SLOPE)

· TEMPORARY ROOF COATING AND SEALANT (OVER)

· EXISTING 24 GAUGE, 16” WIDE STANDING SEAM METAL ROOF PANELS

SLOPED AT +/- 1” PER FOOT MECHANICALLY ATTACHED (OVER)

· EXISTING FIBERGLASS INSULATION (OVER)

· EXISTING METAL BUILDING FRAMING

ROOF AREAS G2, HALLS A, B, C, D, G, H, J, AND J2 – STANDING SEAM METAL

ROOF PANEL SYSTEM (SINGLE ROOF SLOPE)

· TEMPORARY ROOF COATING AND SEALANT (OVER)

· EXISTING 24 GAUGE, 16” WIDE STANDING SEAM METAL ROOF PANELS

SLOPED AT +/- 1” PER FOOT MECHANICALLY ATTACHED (OVER)

· EXISTING FIBERGLASS INSULATION (OVER)

· EXISTING METAL BUILDING FRAMING

WING E – TRAPEZOIDAL METAL ROOF PANEL SYSTEM (GABLE ROOF SLOPE)

· TEMPORARY ROOF COATING AND SEALANT (OVER)

· EXISTING 22 GAUGE, 24” WIDE, TRAPEZOIDAL METAL ROOF PANELS

SLOPED AT +/- 1” PER FOOT MECHANICALLY ATTACHED (OVER)

· EXISTING FIBERGLASS INSULATION (OVER)

· EXISTING METAL BUILDING FRAMING

ROOF AREAS E1, E2, E3, E4, E5, E6, E7, E8, E9, E10, E11, E12, E13, AND E14 –

TRAPEZOIDAL METAL ROOF SYSTEM (SINGLE ROOF SLOPE)

· TEMPORARY ROOF COATING AND SEALANT (OVER)

· EXISTING 22 GAUGE, 24” WIDE TRAPEZOIDAL METAL ROOF PANELS

SLOPED AT +/- 1” PER FOOT MECHANICALLY ATTACHED (OVER)

· EXISTING FIBERGLASS INSULATION (OVER)

· EXISTING METAL BUILDING FRAMING

CIVIL/GRADING REPAIRS

WINGS A, B, C, D, AND G, HALLS A, B, C, D, AND G

· REGRADE EXISTING SOIL TO SHEET FLOW AS SHOWN ON CIVIL

DRAWINGS

· INSTALL CONCRETE SWALES AS SHOWN ON CIVIL DRAWINGS

TEMPORARY REPAIRS

ALL BUILDINGS, WINGS, AND HALLS (EXISTING PRE-ENGINEERED METAL

BUILDING STRUCTURES)

· INSTALL TEMPORARY SHORING AND SUPPORTS AS REQUIRED TO

PROPERLY ENSURE THE STRUCTURAL INTEGRITY OF THE BUILDING IS

NOT COMPROMISED DURING CONSTRUCTION OF THE NEW METAL ROOF

PANEL SYSTEM AND METAL WALL AND SOFFIT PANEL SYSTEMS,

INCLUDING BUT NOT LIMITED TO REPLACEMENT OF DAMAGED WALL

GIRTS, DAMAGED ROOF PURLINS, DAMAGED SECONDARY BRACING,

AND FASTENERS, MECHANICAL EQUIPMENT REPLACEMENT, THEN

REMOVE TEMPORARY SHORING AND SUPPORTS AFTER THE

STRUCTURAL INTEGRITY OF THE BUILDING HAS BEEN RESTORED

ALL BUILDINGS, WINGS, AND HALLS, EXCEPT WING E AND E1 - E14 (EXISTING

PRE-ENGINEERED METAL BUILDING STRUCTURES)

· INSTALL TUFF WRAP INTERIOR PROTECTION SYSTEM TO COLLECT

ROOFING DEBRIS DURING CONSTRUCTION OPERATIONS AND MAINTAIN

ACTIVE VENTILATION WHERE SHOWN

· COORDINATE INSTALLATION OF INTERIOR PROTECTION SYSTEM

LOCATIONS WITH CONSTRUCTION SEQUENCE TO ALLOW PEDESTRIAN

ACCESS TO HALLS AND WINGS TO MAINTAIN OCCUPANT SAFETY

DURING CONSTRUCTION

· REMOVE INTERIOR PROTECTION SYSTEM AND PROPERLY DISPOSE OF

ASSOCIATED DEBRIS ONCE ROOF AREAS ARE COMPLETED

BRAND OR MANUFACTURE'S REFERENCES AREA DESCRIPTIVE

ONLY, AND INDICATE TYPE AND QUALITY TO BE PROVIDED. ALL

REFERENCES TO BRAND OR MANUFACTURER NAMES SHALL BE

INTERPRETED TO INCLUDED THE LANGUAGE "OR A/E

APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING

SPECIFICATIONS WILL BE CONSIDERED. IRRESPECTIVE OF THE

LANGUAGE "OR A/E APPROVED EQUAL" APPEARING IN

CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.

ISSUED FOR PROPOSAL

Exhibit J.6

696-FD-27-P002 2 of 47

G

J

WING D

WING C

WING B

WING A

INFIRMARY

GYM HALL

HALL H

HALL G

HALL A

HALL B

HALL C

HALL D

J

H

J2

SCALE: N.T.S.

EXISTING ELEVATION PLAN

P.YA MAY 17, 2012

N0APPROVEDM

T0NE,

D W. S

TEXAS BOARD

EXAMINERS

TO PRACTICE

ARCHITECTURE

ARCHITECTURAL

R

E.

OF

BY THE

a m te ch so lu tio ns , i nc

AS NOTED

EXISTING ELEVATION

PLAN

C1

DJA,JSF, LAE

DVD

KA

TY

F

R

EE

W

AY

, S U

IT

E

#2

H O

U

ST

O N

, T

EX

AS

t

3.

6.

09/24/2025

STRUCTURAL

BRAND OR MANUFACTURE'S REFERENCES AREA DESCRIPTIVE

ONLY, AND INDICATE TYPE AND QUALITY TO BE PROVIDED. ALL

REFERENCES TO BRAND OR MANUFACTURER NAMES SHALL BE

INTERPRETED TO INCLUDED THE LANGUAGE "OR A/E

APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING

SPECIFICATIONS WILL BE CONSIDERED. IRRESPECTIVE OF THE

LANGUAGE "OR A/E APPROVED EQUAL" APPEARING IN

CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.

TE

XA

S D

EP

AR

TM

EN

T O

F C

R

IM

IN

AL

J U

ST

IC

E W

AL

LA

C E

PA

C

K U

N

IT

R

EP

LA

C

E R

O O

F

- M

U

LT

IP

LE

B

LD

G S.

N

AV

AS

O

TA

, T

EX

AS

ISSUED FOR PROPOSAL

696-FD-27-P002 3 of 47

WING D

WING C

WING B

WING A

INFIRMARY

GYM HALL

HALL H

HALL G

HALL A

HALL B

HALL C

HALL D

J

H

J2

SCALE: N.T.S.

PROPOSED ELEVATION PLAN

SCALE: N.T.S.

SWALE DETAIL

LEGEND

PROPOSE SWALE

SWALE FLOW

DRAIN DITCH CENTER LINE

P.YA MAY 17, 2012

N0APPROVEDM

T0NE,

D W. S

TEXAS BOARD

EXAMINERS

TO PRACTICE

ARCHITECTURE

ARCHITECTURAL

R

E.

OF

BY THE

a m te ch so lu tio ns , i nc

AS NOTED

PROPOSE ELEVATION

PLAN

C2

DVD

KA

TY

F

R

EE

W

AY

, S U

IT

E

#2

H O

U

ST

O N

, T

EX

AS

t

3.

6.

DJA,JSF, LAE

BRAND OR MANUFACTURE'S REFERENCES AREA DESCRIPTIVE

ONLY, AND INDICATE TYPE AND QUALITY TO BE PROVIDED. ALL

REFERENCES TO BRAND OR MANUFACTURER NAMES SHALL BE

INTERPRETED TO INCLUDED THE LANGUAGE "OR A/E

APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING

SPECIFICATIONS WILL BE CONSIDERED. IRRESPECTIVE OF THE

LANGUAGE "OR A/E APPROVED EQUAL" APPEARING IN

CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.

TE

XA

S D

EP

AR

TM

EN

T O

F C

R

IM

IN

AL

J U

ST

IC

E W

AL

LA

C E

PA

C

K U

N

IT

R

EP

LA

C

E R

O O

F

- M

U

LT

IP

LE

B

LD

G S.

N

AV

AS

O

TA

, T

EX

AS

ISSUED FOR PROPOSAL

09/24/2025

STRUCTURAL

696-FD-27-P002 4 of 47

STRUCTURAL STEEL NOTES:

DESIGN CRITERIA

COMPONENTS AND CLADDING REQUIREMENTS

θ θ θ θ θ

COLD ROLLED STEEL SPECIFICATIONS

(SSMA)

P.YA MAY 17, 2012

N0APPROVEDM

T0NE,

D W. S

TEXAS BOARD

EXAMINERS

TO PRACTICE

ARCHITECTURE

ARCHITECTURAL

R

E.

OF

BY THE

a m te ch so lu tio ns , i nc

AS NOTED

STRUCTURAL REPAIR

PLAN

S1.0

DJA,JSF

DVD

KA

TY

F

R

EE

W

AY

, S U

IT

E

#2

H O

U

ST

O N

, T

EX

AS

t

3.

6.

BRAND OR MANUFACTURE'S REFERENCES AREA DESCRIPTIVE

ONLY, AND INDICATE TYPE AND QUALITY TO BE PROVIDED. ALL

REFERENCES TO BRAND OR MANUFACTURER NAMES SHALL BE

INTERPRETED TO INCLUDED THE LANGUAGE "OR A/E

APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING

SPECIFICATIONS WILL BE CONSIDERED. IRRESPECTIVE OF THE

LANGUAGE "OR A/E APPROVED EQUAL" APPEARING IN

CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.

TE

XA

S D

EP

AR

TM

EN

T O

F C

R

IM

IN

AL

J U

ST

IC

E W

AL

LA

C E

PA

C

K U

N

IT

R

EP

LA

C

E R

O O

F

- M

U

LT

IP

LE

B

LD

G S.

N

AV

AS

O

TA

, T

EX

AS

ISSUED FOR PROPOSAL

09/24/2025

STRUCTURAL

696-FD-27-P002 5 of 47

WING D

WING C

WING B

WING A

ADMINISTRATION

INFIRMARY

GYM HALL

HALL H

HALL G

HALL A

HALL B

HALL C

HALL D

J

H

SCALE: N.T.S.

DEMOLITION PLAN

HATCH AREA=DEMOLITION AREA. NOTE: REPLACE ALL DIAGONAL BRACING AND ANGLE BRACES AT PURLINS TO BEAMS.

ALLOW 2000 ' FOR PURLIN FOUND DAMAGED OR DAMAGED DURING DEMOLITION.

2.REPLACE 2 PURLINS WITH CORROSION AT TOP FLANGE AT D WING EAST SIDE AND 1 DENTED PURLIN AT A-WING ABOVE KITCHEN.

1.REPAIR CORRODED COLUMN BASE PLATE AT MAIN ENTRANCE WING G REFER TO REPAIR DETAIL 9/S2.2

NOTE: 1. FOR ANGLE REPLACEMENT NEEDED, CONTRACTOR TO FIELD VERIFY AND REPLACE CLIP OR ANGLE AS NEEDED PER DETAIL 1/S2.2

2. FOR CABLE BRACING REPAIRS NEEDED, CONTRACTOR TO FIELD VERIFY AND REPLACE AS NEEDED PER DETAIL 5A-5D/S2.2.

G2

3.ROOF AND WALL PANELS TO BE REMOVED AND REPLACED AND WALL GIRTS TO BE REPAIRED IF NEEDED, CONTRACTOR TO FIELD VERIFY AND REPLACE PER DETAILS ON S2.2

1.

J2

P.YA MAY 17, 2012

N0APPROVEDM

T0NE,

D W. S

TEXAS BOARD

EXAMINERS

TO PRACTICE

ARCHITECTURE

ARCHITECTURAL

R

E.

OF

BY THE

a m te ch so lu tio ns , i nc

AS NOTED

STRUCTURAL REPAIR

PLAN

S2.0

DJA,JSF

DVD

KA

TY

F

R

EE

W

AY

, S U

IT

E

#2

H O

U

ST

O N

, T

EX

AS

t

3.

6.

BRAND OR MANUFACTURE'S REFERENCES AREA DESCRIPTIVE

ONLY, AND INDICATE TYPE AND QUALITY TO BE PROVIDED. ALL

REFERENCES TO BRAND OR MANUFACTURER NAMES SHALL BE

INTERPRETED TO INCLUDED THE LANGUAGE "OR A/E

APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING

SPECIFICATIONS WILL BE CONSIDERED. IRRESPECTIVE OF THE

LANGUAGE "OR A/E APPROVED EQUAL" APPEARING IN

CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.

TE

XA

S D

EP

AR

TM

EN

T O

F C

R

IM

IN

AL

J U

ST

IC

E W

AL

LA

C E

PA

C

K U

N

IT

R

EP

LA

C

E R

O O

F

- M

U

LT

IP

LE

B

LD

G S.

N

AV

AS

O

TA

, T

EX

AS

ISSUED FOR PROPOSAL

09/24/2025

STRUCTURAL

696-FD-27-P002 6 of 47

SCALE: N.T.S.

STEEL FRAMING REPAIR LAYOUT

NOTE: REPLACE ALL DIAGONAL BRACING AND ANGLE BRACES AT PURLINS TO BEAMS.

ALLOW 2000 ' FOR PURLIN FOUND DAMAGED OR DAMAGED DURING DEMOLITION.

2.REPLACE 2 PURLINS WITH CORROSION AT TOP FLANGE AT D WING EAST SIDE AND 1 DENTED PURLIN AT A-WING ABOVE KITCHEN.

1.REPAIR CORRODED COLUMN BASE PLATE AT MAIN ENTRANCE WING G REFER TO REPAIR DETAIL 9/S2.2

2.

2.

NOTE: 1. FOR ANGLE REPLACEMENT NEEDED, CONTRACTOR TO FIELD VERIFY AND REPLACE CLIP OR ANGLE AS NEEDED PER DETAIL 5/S2.2

2. FOR CABLE BRACING REPAIRS NEEDED, CONTRACTOR TO FIELD VERIFY AND REPLACE AS NEEDED PER DETAIL 5A-5D/S2.2.

3.ROOF AND WALL PANELS TO BE REMOVED AND REPLACED AND WALL GIRTS TO BE REPAIRED IF NEEDED, CONTRACTOR TO FIELD VERIFY AND REPLACE PER DETAILS ON S2.2

G

J

WING D

WING C

WING B

WING A

ADMINISTRATION

INFIRMARY

GYM HALL

HALL H

HALL G

HALL A

HALL B

HALL C

HALL D

J

H

G2 1.

J2

P.YA MAY 17, 2012

N0APPROVEDM

T0NE,

D W. S

TEXAS BOARD

EXAMINERS

TO PRACTICE

ARCHITECTURE

ARCHITECTURAL

R

E.

OF

BY THE

a m te ch so lu tio ns , i nc

AS NOTED

STRUCTURAL REPAIR

PLAN

S2.1

DJA,JSF

DVD

KA

TY

F

R

EE

W

AY

, S U

IT

E

#2

H O

U

ST

O N

, T

EX

AS

t

3.

6.

BRAND OR MANUFACTURE'S REFERENCES AREA DESCRIPTIVE

ONLY, AND INDICATE TYPE AND QUALITY TO BE PROVIDED. ALL

REFERENCES TO BRAND OR MANUFACTURER NAMES SHALL BE

INTERPRETED TO INCLUDED THE LANGUAGE "OR A/E

APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING

SPECIFICATIONS WILL BE CONSIDERED. IRRESPECTIVE OF THE

LANGUAGE "OR A/E APPROVED EQUAL" APPEARING IN

CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.

TE

XA

S D

EP

AR

TM

EN

T O

F C

R

IM

IN

AL

J U

ST

IC

E W

AL

LA

C E

PA

C

K U

N

IT

R

EP

LA

C

E R

O O

F

- M

U

LT

IP

LE

B

LD

G S.

N

AV

AS

O

TA

, T

EX

AS

ISSUED FOR PROPOSAL

09/24/2025

STRUCTURAL

696-FD-27-P002 7 of 47

SCALE: N.T.S.

TYPICAL FRAMING REPAIR DETAILS

ANGLE TO BEAM/PURLIN CONNECTION1

SCALE: N.T.S.

PURLIN TO PURLIN/BEAM/COLUMN CLIP/PLATE 2

SCALE: N.T.S

SCALE: N.T.S.

WEB w/EYEBOLT ATTACHMENT

CABLE TO COLUMN/BEAM OR RAFTER

5A CABLE BRACE SLOT IN GIRT/PURLIN5B SCALE: N.T.S.

SIDE VIEW CABLE BRACE SLOT IN PURLIN5C SCALE: N.T.S. TOP VIEW CABLE BRACE SLOT IN PURLIN5D SCALE: N.T.S.

TYPICAL EXHAUST FAN Z-PURLIN STRUCTURAL DETAIL3

SCALE: N.T.S.

EXHAUST FAN PURLIN CLIP ATTACHMENT4

SCALE: N.T.S.

COLDFORM COLUMN TO WALL GIRTS6 SCALE: N.T.S.

COLDFORM COLUMN TO WALL GIRTS7 SCALE: N.T.S.

GIRT CONN. AT CORNER COLUMN 8 SCALE: N.T.S.

COLUMN BASE PLATE BOLT FILLER METAL REPAIR9 SCALE: N.T.S.

P.YA MAY 17, 2012

N0APPROVEDM

T0NE,

D W. S

TEXAS BOARD

EXAMINERS

TO PRACTICE

ARCHITECTURE

ARCHITECTURAL

R

E.

OF

BY THE

a m te ch so lu tio ns , i nc

AS NOTED

STRUCTURAL FRAMING

REPAIR DETAILS

S2.2

DJA,JSF

DVD

KA

TY

F

R

EE

W

AY

, S U

IT

E

#2

H O

U

ST

O N

, T

EX

AS

t

3.

6.

BRAND OR MANUFACTURE'S REFERENCES AREA DESCRIPTIVE

ONLY, AND INDICATE TYPE AND QUALITY TO BE PROVIDED. ALL

REFERENCES TO BRAND OR MANUFACTURER NAMES SHALL BE

INTERPRETED TO INCLUDED THE LANGUAGE "OR A/E

APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING

SPECIFICATIONS WILL BE CONSIDERED. IRRESPECTIVE OF THE

LANGUAGE "OR A/E APPROVED EQUAL" APPEARING IN

CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.

TE

XA

S D

EP

AR

TM

EN

T O

F C

R

IM

IN

AL

J U

ST

IC

E W

AL

LA

C E

PA

C

K U

N

IT

R

EP

LA

C

E R

O O

F

- M

U

LT

IP

LE

B

LD

G S.

N

AV

AS

O

TA

, T

EX

AS

ISSUED FOR PROPOSAL

09/24/2025

STRUCTURAL

696-FD-27-P002 8 of 47

WING D

WING C

WING B

WING A

ADMINISTRATION

INFIRMARY

GYM HALL

HALL H

HALL G

HALL A

HALL B

HALL C

HALL D

J

H

SCALE: N.T.S.

ROOF PLAN FOR STEEL FRAME

SCALE: NTS

Z-PURLIN AND R-PANEL ELEVATION

SCALE: NTS

Z-PURLIN TO BEAM CONNECTION1

NOTE: REPLACE ALL DIAGONAL BRACING AND ANGLE BRACES AT PURLINS TO BEAMS.

ALLOW 2000 ' FOR PURLIN FOUND DAMAGED OR DAMAGED DURING DEMOLITION.

2.REPLACE 2 PURLINS WITH CORROSION AT TOP FLANGE AT D WING EAST SIDE AND 1 DENTED PURLIN AT A-WING ABOVE KITCHEN.

1.REPAIR CORRODED COLUMN BASE PLATE AT MAIN ENTRANCE WING G REFER TO REPAIR DETAIL 9/S2.2

NOTE: 1. FOR ANGLE REPLACEMENT NEEDED, CONTRACTOR TO FIELD VERIFY AND REPLACE CLIP OR ANGLE AS NEEDED PER DETAIL 5/S2.2

2. FOR CABLE BRACING REPAIRS NEEDED, CONTRACTOR TO FIELD VERIFY AND REPLACE AS NEEDED PER DETAIL 5A-5D/S2.2.

3.ROOF AND WALL PANELS TO BE REMOVED AND REPLACED AND WALL GIRTS TO BE REPAIRED IF NEEDED, CONTRACTOR TO FIELD VERIFY AND REPLACE PER DETAILS ON S2.2

P.YA MAY 17, 2012

N0APPROVEDM

T0NE,

D W. S

TEXAS BOARD

EXAMINERS

TO PRACTICE

ARCHITECTURE

ARCHITECTURAL

R

E.

OF

BY THE

a m te ch so lu tio ns , i nc

AS NOTED

STRUCTURAL REPAIR

PLAN

S3.0

DJA,JSF

DVD

KA

TY

F

R

EE

W

AY

, S U

IT

E

#2

H O

U

ST

O N

, T

EX

AS

t

3.

6.

BRAND OR MANUFACTURE'S REFERENCES AREA DESCRIPTIVE

ONLY, AND INDICATE TYPE AND QUALITY TO BE PROVIDED. ALL

REFERENCES TO BRAND OR MANUFACTURER NAMES SHALL BE

INTERPRETED TO INCLUDED THE LANGUAGE "OR A/E

APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING

SPECIFICATIONS WILL BE CONSIDERED. IRRESPECTIVE OF THE

LANGUAGE "OR A/E APPROVED EQUAL" APPEARING IN

CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.

TE

XA

S D

EP

AR

TM

EN

T O

F C

R

IM

IN

AL

J U

ST

IC

E W

AL

LA

C E

PA

C

K U

N

IT

R

EP

LA

C

E R

O O

F

- M

U

LT

IP

LE

B

LD

G S.

N

AV

AS

O

TA

, T

EX

AS

ISSUED FOR PROPOSAL

09/24/2025

STRUCTURAL

696-FD-27-P002 9 of 47

M

M2

X

W

Y Z

AA

G G2

Q

R

B

A

N

N1

T

U

S

J

M3

WING D

WING C

WING B

WING A

RESTRICTION

HOUSING

ADMINISTRATION

FOOD

SERVICE

INFIRMARY

EDUCATION

LAUNDRY

GYM

N.I.C.

N.I.C.

N.I.C.

BB

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

WING E

HALLN.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

HALL H

HALL G

HALL A

HALL B

HALL C

HALL D

D1 N.I.C.

J

H

E1

E2

E3

E4

E5

E6

E7

E14

E13

E12

E11

E10

E9

E8

WING D

WING C

HALL D

EF EF EF EF EF EF

EF EF EF EF EF EF

EF

SP SP

EF

EF

EF

EF EF EF EF EF

EF EF EF EF EF

MAU

EF

SP SP

EF

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SUPPORT

CURB

SUPPORT

CURB

DS DS

DS DS

SB SB

SBSB

WALL LIGHT

WALL LIGHT

WALL LIGHTWALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

GUTTER

GUTTER

SPEAKER

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

WALL LIGHTWALL LIGHT

D1 N.I.C.

SL

SL

SL

SL

SL

SL

SL

SL

HALL C

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP. D1

TYP.

D1

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D3

TYP.

D3

TYP.

D4

TYP.

D4

TYP.

1 2 3 4 5

RIDGERIDGE

1 4 5 7

WING B

8 6

6 8

7 7

RIDGERIDGE

7 7

1 2 3 4 5

6 1 4 5

P.YA MAY 17, 2012

N0APPROVEDM

T0NE,

D W. S

TEXAS BOARD

EXAMINERS

TO PRACTICE

ARCHITECTURE

ARCHITECTURAL

R

E.

OF

BY THE

a m te ch so lu tio ns , i nc

AS NOTED

ROOF PLAN WING C, HALL C, WING

D, AND HALL D - DEMOLITION

RD1

WING D, AND HALL D - DEMOLITION

1/16"=1'-0"SCALE:

EF

SP

RTU/MAU ROOF TOP UNIT/

EXHAUST FAN

SOIL PIPE

SYMBOL LEGEND

TAPER LINE

SCUPPER / OVERFLOWSC/OSC

DOWNSPOUT

SB SPLASH BLOCK

DS

TRAFFIC PAD

MAKE-UP HANDLER UNIT

KEY PLAN

NORTH

LEGEND

BASE BID

NOT IN CONTRACT (N.I.C.)

NORTH

C.C.G.

KA

TY

F

R

EE

W

AY

, S U

IT

E

#2

H O

U

ST

O N

, T

EX

AS

t

3.

6.

ROOF PLAN WING C, HALL C,

NOT IN CONTRACT (N.I.C.)

LEGEND

DEMOLITION NOTES (DOES NOT APPLY TO WING E AND ROOF AREAS E1 – E14):

1 PROVIDE AND INSTALL TEMPORARY SHORING AND SUPPORTS TO PROPERLY ENSURE THE STRUCTURAL INTEGRITY OF THE BUILDING IS NOT COMPROMISED DURING CONSTRUCTION OF THE NEW METAL ROOF PANEL SYSTEM AND METAL WALL AND SOFFIT PANEL SYSTEMS, INCLUDING BUT NOT LIMITED TO REPLACEMENT OF DAMAGED WALL GIRTS, DAMAGED ROOF PURLINS, DAMAGED SECONDARY BRACING, AND FASTENERS, MECHANICAL EQUIPMENT REPLACEMENT, THEN REMOVE TEMPORARY SHORING AND SUPPORTS AFTER THE STRUCTURAL INTEGRITY OF THE

BUILDING HAS BEEN RESTORED

2 REMOVE DAMAGED EXISTING WALL GIRTS AND DAMAGED EXISTING SECONDARY BRACING AT SELECT LOCATIONS AS

SHOWN ON STRUCTURAL DRAWINGS

3 REMOVE DAMAGED EXISTING ROOF PURLINS AND DAMAGED EXISTING SECONDARY BRACING AT SELECT LOCATIONS

AS SHOWN ON STRUCTURAL DRAWINGS

4 REMOVE EXISTING COATED STANDING SEAM METAL ROOF PANEL SYSTEM INCLUDING BUT NOT LIMITED TO CLIPS, FASTENERS, INSULATION, MECHANICAL CURBS, ROOF FLASHINGS, METAL GUTTERS, DOWNSPOUTS, AND SPLASH

BLOCKS

5 REPLACE OR EXTEND EXISTING PIPE AND HOT STACK PENETRATIONS AS REQUIRED TO INSTALL NEW METAL ROOF

SYSTEM

6 REMOVE EXISTING INSULATED METAL WALL PANELS INCLUDING BUT LIMITED TO TRIM, CLIPS, FASTENERS, SEALANT, AND INSULATION

7 REMOVE EXISTING ROOF MOUNTED MECHANICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO ELECTRICAL AND

PLUMBING APPURTENANCES, AS SHOWN ON MECHANICAL DRAWINGS

8 REMOVE EXISTING WALL MOUNTED LIGHT FIXTURE AS SHOWN ON ELECTRICAL DRAWINGS

NOTE:

CABLE BRACING SEE STRUCT. DRAWINGS, TYP.

BRAND OR MANUFACTURE'S REFERENCES AREA DESCRIPTIVE

ONLY, AND INDICATE TYPE AND QUALITY TO BE PROVIDED. ALL

REFERENCES TO BRAND OR MANUFACTURER NAMES SHALL BE

INTERPRETED TO INCLUDED THE LANGUAGE "OR A/E

APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING

SPECIFICATIONS WILL BE CONSIDERED. IRRESPECTIVE OF THE

LANGUAGE "OR A/E APPROVED EQUAL" APPEARING IN

CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.

TE

XA

S D

EP

AR

TM

EN

T O

F C

R

IM

IN

AL

J U

ST

IC

E W

AL

LA

C E

PA

C

K U

N

IT

R

EP

LA

C

E R

O O

F

- M

U

LT

IP

LE

B

LD

G S.

N

AV

AS

O

TA

, T

EX

AS

J.R.,D.V, R.S.

09/24/2025

ISSUED FOR PROPOSAL

696-FD-27-P002 10 of 47

M

M2

X

W

Y Z

AA

G G2

Q

R

B

A

N

N1

T

U

S

M3

WING D

WING C

WING B

WING A

RESTRICTION

HOUSING

ADMINISTRATION

FOOD

SERVICE

INFIRMARY

EDUCATION

LAUNDRY

GYM

N.I.C.

N.I.C.

N.I.C.

BB

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

WING E

HALLN.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

J

H

E1

E2

E3

E4

E5

E6

E7

E14

E13

E12

E11

E10

E9

E8

D1

J

HALL H

HALL G

HALL A

HALL B

HALL C

HALL D

WING B

WING A

HALL A

HALL B

DS

EF EF EF

EF EF EF

SP SP

EF EF

EF EF EF

EF EF EF

MAU

EF

EF

EF

EFEF EFEF EF

EF EF EF EF

SP

EF EF

SP

ANT/EP

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SUPPORT

CURB

SUPPORT

CURB

DS

DS DS

SB

SB SB

WALL LIGHT

WALL LIGHT

WALL LIGHTWALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

GUTTER

GUTTER

SL

SL

SL

SL

SL

SL

SL

SL

SLSL

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D3

TYP.

D3

TYP.

D4

TYP.

D4

TYP.

HALL C

WING C

G

1 2 3 4 5

1 4 5 78 6

6 8

7 7

7 7

1 2 3 4 5

6 6

6 1 4 5

RIDGERIDGE

RIDGERIDGE

P.YA MAY 17, 2012

N0APPROVEDM

T0NE,

D W. S

TEXAS BOARD

EXAMINERS

TO PRACTICE

ARCHITECTURE

ARCHITECTURAL

R

E.

OF

BY THE

a m te ch so lu tio ns , i nc

AS NOTED

RD2

WING B, AND HALL B - DEMOLITION

1/16"=1'-0"SCALE:

EF

SP

EXHAUST FAN

SOIL PIPE

SYMBOL LEGEND

TAPER LINE

SCUPPER / OVERFLOWSC/OSC

DOWNSPOUT

SB SPLASH BLOCK

DS

TRAFFIC PAD

KEY PLAN

NORTH

LEGEND

BASE BID

NOT IN CONTRACT (N.I.C.)

NORTH

C.C.G.

KA

TY

F

R

EE

W

AY

, S U

IT

E

#2

H O

U

ST

O N

, T

EX

AS

t

3.

6.

ANT/EP ANTENNA/ELECTRICAL POLE

ROOF PLAN WING A, HALL A,

ROOF PLAN WING A, HALL A, WING

B, AND HALL B - DEMOLITION

DEMOLITION NOTES (DOES NOT APPLY TO WING E AND ROOF AREAS E1 – E14):

1 PROVIDE AND INSTALL TEMPORARY SHORING AND SUPPORTS TO PROPERLY ENSURE THE STRUCTURAL INTEGRITY OF THE BUILDING IS NOT COMPROMISED DURING CONSTRUCTION OF THE NEW METAL ROOF PANEL SYSTEM AND METAL WALL AND SOFFIT PANEL SYSTEMS, INCLUDING BUT NOT LIMITED TO REPLACEMENT OF DAMAGED WALL GIRTS, DAMAGED ROOF PURLINS, DAMAGED SECONDARY BRACING, AND FASTENERS, MECHANICAL EQUIPMENT REPLACEMENT, THEN REMOVE TEMPORARY SHORING AND SUPPORTS AFTER THE STRUCTURAL INTEGRITY OF THE

BUILDING HAS BEEN RESTORED

2 REMOVE DAMAGED EXISTING WALL GIRTS AND DAMAGED EXISTING SECONDARY BRACING AT SELECT LOCATIONS AS

SHOWN ON STRUCTURAL DRAWINGS

3 REMOVE DAMAGED EXISTING ROOF PURLINS AND DAMAGED EXISTING SECONDARY BRACING AT SELECT LOCATIONS

AS SHOWN ON STRUCTURAL DRAWINGS

4 REMOVE EXISTING COATED STANDING SEAM METAL ROOF PANEL SYSTEM INCLUDING BUT NOT LIMITED TO CLIPS, FASTENERS, INSULATION, MECHANICAL CURBS, ROOF FLASHINGS, METAL GUTTERS, DOWNSPOUTS, AND SPLASH

BLOCKS

5 REPLACE OR EXTEND EXISTING PIPE AND HOT STACK PENETRATIONS AS REQUIRED TO INSTALL NEW METAL ROOF

SYSTEM

6 REMOVE EXISTING INSULATED METAL WALL PANELS INCLUDING BUT LIMITED TO TRIM, CLIPS, FASTENERS, SEALANT, AND INSULATION

7 REMOVE EXISTING ROOF MOUNTED MECHANICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO ELECTRICAL AND

PLUMBING APPURTENANCES, AS SHOWN ON MECHANICAL DRAWINGS

8 REMOVE EXISTING WALL MOUNTED LIGHT FIXTURE AS SHOWN ON ELECTRICAL DRAWINGS

NOTE:

CABLE BRACING SEE STRUCT. DRAWINGS, TYP.

RTU/MAU ROOF TOP UNIT/

MAKE-UP HANDLER UNIT

BRAND OR MANUFACTURE'S REFERENCES AREA DESCRIPTIVE

ONLY, AND INDICATE TYPE AND QUALITY TO BE PROVIDED. ALL

REFERENCES TO BRAND OR MANUFACTURER NAMES SHALL BE

INTERPRETED TO INCLUDED THE LANGUAGE "OR A/E

APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING

SPECIFICATIONS WILL BE CONSIDERED. IRRESPECTIVE OF THE

LANGUAGE "OR A/E APPROVED EQUAL" APPEARING IN

CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.

TE

XA

S D

EP

AR

TM

EN

T O

F C

R

IM

IN

AL

J U

ST

IC

E W

AL

LA

C E

PA

C

K U

N

IT

R

EP

LA

C

E R

O O

F

- M

U

LT

IP

LE

B

LD

G S.

N

AV

AS

O

TA

, T

EX

AS

J.R.,D.V, R.S.

09/24/2025

ISSUED FOR PROPOSAL

696-FD-27-P002 11 of 47

M

M2

X

W

Y Z

AA

G G2

Q

R

B

A

N

N1

T

U

S

M3

WING D

WING C

WING B

WING A

RESTRICTION

HOUSING

ADMINISTRATION

FOOD

SERVICE

INFIRMARY

EDUCATION

LAUNDRY

GYM

N.I.C.

N.I.C.

N.I.C.

BB

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

WING E

HALLN.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

J

H

E1

E2

E3

E4

E5

E6

E7

E14

E13

E12

E11

E10

E9

E8

D1

J

HALL H

HALL G

HALL A

HALL B

HALL C

HALL D

G G2

RESTRICTION

HOUSING

FOOD

SERVICE

INFIRMARY

HALL H

HALL G

EF

EF

EF

EF

EF

EF

SP

SP

SP

SP

SP

EF

V

V V

SUPPORT

CURB MAU

SF

SF

EF

EF

RTU

WALL LIGHT

SD

ANT/EP

EF

DS

DS

HSHS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

DS DS

SB SB

ANT/EP

WALL LIGHT

WALL LIGHT WALL LIGHT

WALL LIGHT

WALL LIGHT

SB

DS

GUTTER

SL

SL

SL

SL

SB

DS SB

DS

SL

SL

CURBSB

DS

GUTTERSB

DS

SB

DS

SB

DS

SB

DS

HV

MAU

SD

AB

PP

EF

CD SP

RTU

EF

EFEF PP

PP PP

SP

PP

PPSF

PP

PP HS

MAU

PP

SP

SP

PP

PP

PP

SF

EFPP

SP

PP

EF

MAU

PP

PP

EFSP PP

SF

SP V

EF

PP

PP

AB

EF

RTU

PP

PP

SF

PP

SD

PP

PP

RTU

EFMAU

SP

PPPP

EF

MAU

MAU

EF

PP

PP

EF

SP

V

PP

PP

PP

PP

PP

EF

PP

RTU

PP

PP

SF

PPPP PP

PP

V

SF SP

EF

PPPP

EF

PP

EF

PPPP SP

EF

SP

EF

SP

V V

EF VANT

GUTTERGUTTER

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

ADMINISTRATION

SUPPORT

EF

D2

TYP. D2

TYP.

D2

TYP.

D2

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP. D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D3

TYP.

D3

TYP.

D3

TYP.

D3

TYP.

D3

TYP.

D3

TYP.

D4

TYP.

D4

TYP.

D4

TYP.

D4

TYP.

WING A

HALL A

J2

J

1 2 3 4 5

RIDGERIDGE

RIDGERIDGE

SLSL

SL SL

7 78

6 6

8 6

6 7

1 2 3 4 5 7

EF

TYP.

WALL LIGHT

EF

WALL LIGHT

SB

DS

SB

DS

P.YA MAY 17, 2012

N0APPROVEDM

T0NE,

D W. S

TEXAS BOARD

EXAMINERS

TO PRACTICE

ARCHITECTURE

ARCHITECTURAL

R

E.

OF

BY THE

a m te ch so lu tio ns , i nc

AS NOTED

RD3

G2, H, AND HALL H - DEMOLITION

1/16"=1'-0"SCALE:

EF

PP

V

SP

EXHAUST FAN

FLUE / VENT

PENETRATION POCKET

SOIL PIPE

SYMBOL LEGEND

TAPER LINE

SCUPPER / OVERFLOWSC/OSC

DOWNSPOUT

SB SPLASH BLOCK

DS

TRAFFIC PAD

HS HOT STACK

GUY WIRE

AB ABANDONED CURB

GAS GAS LINE

CD CONDENSATION DRAIN

KEY PLAN

NORTH

LEGEND

BASE BID

NOT IN CONTRACT (N.I.C.)

NORTH

C.C.G.

KA

TY

F

R

EE

W

AY

, S U

IT

E

#2

H O

U

ST

O N

, T

EX

AS

t

3.

6.

ROOF PLAN G, HALL G,

ROOF PLAN G, HALL G, G2

H, AND HALL H - DEMOLITION

ANT/EP ANTENNA/ELECTRICAL POLE

DEMOLITION NOTES (DOES NOT APPLY TO WING E AND ROOF AREAS E1 – E14):

1 PROVIDE AND INSTALL TEMPORARY SHORING AND SUPPORTS TO PROPERLY ENSURE THE STRUCTURAL INTEGRITY OF THE BUILDING IS NOT COMPROMISED DURING CONSTRUCTION OF THE NEW METAL ROOF PANEL SYSTEM AND METAL WALL AND SOFFIT PANEL SYSTEMS, INCLUDING BUT NOT LIMITED TO REPLACEMENT OF DAMAGED WALL GIRTS, DAMAGED ROOF PURLINS, DAMAGED SECONDARY BRACING, AND FASTENERS, MECHANICAL EQUIPMENT REPLACEMENT, THEN REMOVE TEMPORARY SHORING AND SUPPORTS AFTER THE STRUCTURAL INTEGRITY OF THE

BUILDING HAS BEEN RESTORED

2 REMOVE DAMAGED EXISTING WALL GIRTS AND DAMAGED EXISTING SECONDARY BRACING AT SELECT LOCATIONS AS

SHOWN ON STRUCTURAL DRAWINGS

3 REMOVE DAMAGED EXISTING ROOF PURLINS AND DAMAGED EXISTING SECONDARY BRACING AT SELECT LOCATIONS

AS SHOWN ON STRUCTURAL DRAWINGS

4 REMOVE EXISTING COATED STANDING SEAM METAL ROOF PANEL SYSTEM INCLUDING BUT NOT LIMITED TO CLIPS, FASTENERS, INSULATION, MECHANICAL CURBS, ROOF FLASHINGS, METAL GUTTERS, DOWNSPOUTS, AND SPLASH

BLOCKS

5 REPLACE OR EXTEND EXISTING PIPE AND HOT STACK PENETRATIONS AS REQUIRED TO INSTALL NEW METAL ROOF

SYSTEM

6 REMOVE EXISTING INSULATED METAL WALL PANELS INCLUDING BUT LIMITED TO TRIM, CLIPS, FASTENERS, SEALANT, AND INSULATION

7 REMOVE EXISTING ROOF MOUNTED MECHANICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO ELECTRICAL AND

PLUMBING APPURTENANCES, AS SHOWN ON MECHANICAL DRAWINGS

8 REMOVE EXISTING WALL MOUNTED LIGHT FIXTURE AS SHOWN ON ELECTRICAL DRAWINGS

NOTE:

CABLE BRACING SEE STRUCT. DRAWINGS, TYP.

RTU/MAU ROOF TOP UNIT/

MAKE-UP HANDLER UNIT

SD SUPPLY DUCT

BRAND OR MANUFACTURE'S REFERENCES AREA DESCRIPTIVE

ONLY, AND INDICATE TYPE AND QUALITY TO BE PROVIDED. ALL

REFERENCES TO BRAND OR MANUFACTURER NAMES SHALL BE

INTERPRETED TO INCLUDED THE LANGUAGE "OR A/E

APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING

SPECIFICATIONS WILL BE CONSIDERED. IRRESPECTIVE OF THE

LANGUAGE "OR A/E APPROVED EQUAL" APPEARING IN

CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.

TE

XA

S D

EP

AR

TM

EN

T O

F C

R

IM

IN

AL

J U

ST

IC

E W

AL

LA

C E

PA

C

K U

N

IT

R

EP

LA

C

E R

O O

F

- M

U

LT

IP

LE

B

LD

G S.

N

AV

AS

O

TA

, T

EX

AS

J.R.,D.V, R.S.

09/24/2025

ISSUED FOR PROPOSAL

696-FD-27-P002 12 of 47

M

M2

X

W

Y Z

AA

G G2

Q

R

B

A

N

N1

T

U

S

M3

WING D

WING C

WING B

WING A

RESTRICTION

HOUSING

ADMINISTRATION

FOOD

SERVICE

INFIRMARY

EDUCATION

LAUNDRY

GYM

N.I.C.

N.I.C.

N.I.C.

BB

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

WING E

HALLN.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

J

H

E1

E2

E3

E4

E5

E6

E7

E14

E13

E12

E11

E10

E9

E8

D1

J

HALL H

HALL G

HALL A

HALL B

HALL C

HALL D

J2

J

M3

SB

DS

SB

DS

SB

DS

EF EF EF EF

SP

EF

V V V V

V V V V V V

EF

V

EF

V

SP

V V V

V

SB

DS

SB

DS

SB

DS

SL SL

SL

SL

SB

DS

WALL LIGHT

PP

PP

LADDER

SB

DS

SL

SL

GUTTER

GUTTER

GUTTER

SUPPORT

RTU

PPGUTTER

GUTTER

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

EDUCATION

LAUNDRY

GYM

HALL

J

GUTTER

SP

EF

V

EF

V

V

AB

V

V

EF

AB

V

SP

PPPP

PPPP

EF

AB

PPPP

PPPP

V

PP

PP

PP

PP

PP

PP

DS

AB

PP

PP

PP

PP

PP

PP

DS

V V

V

EFSP

V

V

SB

DS

DS SB

DS

SB

DS

SB

DS

SB

DS

SL SL SL SL

SL

SLSL

V

SB

DS

W W

W W

W

W W

GUTTER

N.I.C.

CURB

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D3

TYP.

D3

TYP.

D3

TYP.

D4

TYP.

D4

TYP.

D4

TYP.

D4

TYP.

HALL H

H

RELOCATE EXIST. PIPING

TO ALLOW NEW ROOF

INSTALLATION- SEE

MECH. DRAWINGS

1 2 3 4 5

RIDGERIDGE

RIDGE RIDGE

TYP.

6 6

TYP.

1 2 3 4 5 7

77 7

7 7

WALL LIGHT

WALL LIGHT

WALL LIGHT

P.YA MAY 17, 2012

N0APPROVEDM

T0NE,

D W. S

TEXAS BOARD

EXAMINERS

TO PRACTICE

ARCHITECTURE

ARCHITECTURAL

R

E.

OF

BY THE

a m te ch so lu tio ns , i nc

AS NOTED

RD4

J, HALL J, AND J2 - DEMOLITION

1/16"=1'-0"SCALE:

EF

PP

V

SP

W

E

RTU/AHU

E

W

ROOF TOP UNIT/

EXHAUST FAN

FLUE / VENT

PENETRATION POCKET

SOIL PIPE

SYMBOL LEGEND

ELECTRICAL

TAPER LINE

SCUPPER / OVERFLOWSC/OSC

DOWNSPOUT

SB SPLASH BLOCK

DS

TRAFFIC PAD

INSULATED WATER

AB ABANDONED CURB

AIR HANDLER UNIT

KEY PLAN

NORTH

LEGEND

BASE BID

NOT IN CONTRACT (N.I.C.)

NORTH

C.C.G.

KA

TY

F

R

EE

W

AY

, S U

IT

E

#2

H O

U

ST

O N

, T

EX

AS

t

3.

6.

ROOF PLAN GYM,

ROOF PLAN GYM, J, HALL

J, AND J2 - DEMOLITION

DUCT SUPPLYDS

NOT IN CONTRACT (N.I.C.)

LEGEND

DEMOLITION NOTES (DOES NOT APPLY TO WING E AND ROOF AREAS E1 – E14):

1 PROVIDE AND INSTALL TEMPORARY SHORING AND SUPPORTS TO PROPERLY ENSURE THE STRUCTURAL INTEGRITY OF THE BUILDING IS NOT COMPROMISED DURING CONSTRUCTION OF THE NEW METAL ROOF PANEL SYSTEM AND METAL WALL AND SOFFIT PANEL SYSTEMS, INCLUDING BUT NOT LIMITED TO REPLACEMENT OF DAMAGED WALL GIRTS, DAMAGED ROOF PURLINS, DAMAGED SECONDARY BRACING, AND FASTENERS, MECHANICAL EQUIPMENT REPLACEMENT, THEN REMOVE TEMPORARY SHORING AND SUPPORTS AFTER THE STRUCTURAL INTEGRITY OF THE

BUILDING HAS BEEN RESTORED

2 REMOVE DAMAGED EXISTING WALL GIRTS AND DAMAGED EXISTING SECONDARY BRACING AT SELECT LOCATIONS AS

SHOWN ON STRUCTURAL DRAWINGS

3 REMOVE DAMAGED EXISTING ROOF PURLINS AND DAMAGED EXISTING SECONDARY BRACING AT SELECT LOCATIONS

AS SHOWN ON STRUCTURAL DRAWINGS

4 REMOVE EXISTING COATED STANDING SEAM METAL ROOF PANEL SYSTEM INCLUDING BUT NOT LIMITED TO CLIPS, FASTENERS, INSULATION, MECHANICAL CURBS, ROOF FLASHINGS, METAL GUTTERS, DOWNSPOUTS, AND SPLASH

BLOCKS

5 REPLACE OR EXTEND EXISTING PIPE AND HOT STACK PENETRATIONS AS REQUIRED TO INSTALL NEW METAL ROOF

SYSTEM

6 REMOVE EXISTING INSULATED METAL WALL PANELS INCLUDING BUT LIMITED TO TRIM, CLIPS, FASTENERS, SEALANT, AND INSULATION

7 REMOVE EXISTING ROOF MOUNTED MECHANICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO ELECTRICAL AND

PLUMBING APPURTENANCES, AS SHOWN ON MECHANICAL DRAWINGS

8 REMOVE EXISTING WALL MOUNTED LIGHT FIXTURE AS SHOWN ON ELECTRICAL DRAWINGS

NOTE:

CABLE BRACING SEE STRUCT. DRAWINGS, TYP.

BRAND OR MANUFACTURE'S REFERENCES AREA DESCRIPTIVE

ONLY, AND INDICATE TYPE AND QUALITY TO BE PROVIDED. ALL

REFERENCES TO BRAND OR MANUFACTURER NAMES SHALL BE

INTERPRETED TO INCLUDED THE LANGUAGE "OR A/E

APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING

SPECIFICATIONS WILL BE CONSIDERED. IRRESPECTIVE OF THE

LANGUAGE "OR A/E APPROVED EQUAL" APPEARING IN

CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.

TE

XA

S D

EP

AR

TM

EN

T O

F C

R

IM

IN

AL

J U

ST

IC

E W

AL

LA

C E

PA

C

K U

N

IT

R

EP

LA

C

E R

O O

F

- M

U

LT

IP

LE

B

LD

G S.

N

AV

AS

O

TA

, T

EX

AS

J.R.,D.V, R.S.

09/24/2025

ISSUED FOR PROPOSAL

696-FD-27-P002 13 of 47

M

M2

X

W

Y Z

AA

G G2

Q

R

B

A

N

N1

T

U

S

M3

WING D

WING C

WING B

WING A

RESTRICTION

HOUSING

ADMINISTRATION

FOOD

SERVICE

INFIRMARY

EDUCATION

LAUNDRY

GYM

N.I.C.

N.I.C.

N.I.C.

BB

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

WING E

HALLN.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

J

H

E1

E2

E3

E4

E5

E6

E7

E14

E13

E12

E11

E10

E9

E8

D1

J

HALL H

HALL G

HALL A

HALL B

HALL C

HALL D

WING E

SL SL

SL SL

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

V

V

SA

SA

SA

SA

SA

SA

ANT/EP

V

V

ANT/EP

SP

SP

SP

SP

V

V

V

V

V V

SP

SP

V

V

ACCU ACCU

PP

SP

SP

SP

SP

V

V

V

V

V

V

SP

SP

EF

V

V

V

V

EF

V

V

V

SP

SP

SP

V

EF

PP

V

V

VE1

E2

E3

E4

E5

E6

E7

E14

E13

E12

E11

E10

E9

E8

D2

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D2

TYP.

D2

TYP.

D3

TYP.

D3

TYP.

D3

TYP.

D3

TYP.

D3

TYP.

D4

TYP.

D4

TYP.

GUTTERGUTTER

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

R

ID

G E

R

ID

G E

TYP.

P.YA MAY 17, 2012

N0APPROVEDM

T0NE,

D W. S

TEXAS BOARD

EXAMINERS

TO PRACTICE

ARCHITECTURE

ARCHITECTURAL

R

E.

OF

BY THE

a m te ch so lu tio ns , i nc

AS NOTED

ROOF PLAN WING E-E14

- DEMOLITION

RD5

ROOF PLAN WING E-E14 - DEMOLITION

1/16"=1'-0"SCALE:

EF

V

SP

EXHAUST FAN

FLUE / VENT

SOIL PIPE

SYMBOL LEGEND

TAPER LINE

SCUPPER / OVERFLOWSC/OSC

DOWNSPOUT

SB SPLASH BLOCK

DS

KEY PLAN

NORTH

LEGEND

BASE BID

NOT IN CONTRACT (N.I.C.)

NORTH

C.C.G.

KA

TY

F

R

EE

W

AY

, S U

IT

E

#2

H O

U

ST

O N

, T

EX

AS

t

3.

6.

SA

ANT/EP ANTENNA/ELECTRICAL POLE

SUPPORT ANCHOR

DEMOLITION NOTES (APPLIES TO WING E AND ROOF AREAS E1 – E14 ONLY):

1 REPAIR ANY DAMAGE TO EXISTING COATED TRAPEZOIDAL METAL ROOF PANEL SYSTEM AS

REQUIRED FOR INSTALLATION OF NEW RETROFIT SUB-PURLIN SYSTEM

2 REPLACE OR EXTEND EXISTING PIPE AND HOT STACK PENETRATIONS AS REQUIRED TO INSTALL

NEW METAL ROOF SYSTEM

3 REMOVE EXISTING ROOF MOUNTED MECHANICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO

ELECTRICAL AND PLUMBING APPURTENANCES, AS SHOWN ON MECHANICAL DRAWINGS

4 REMOVE EXISTING WALL MOUNTED LIGHT FIXTURE AS SHOWN ON ELECTRICAL DRAWINGS

5 REMOVE EXISTING GUTTER INCLUDING BUT NOT LIMITED TO DOWNSPOUTS AND SPLASH BLOCK

6 REMOVE EXISTING SUPPORT ANCHOR

NOTE:

CABLE BRACING SEE STRUCT. DRAWINGS, TYP.

BRAND OR MANUFACTURE'S REFERENCES AREA DESCRIPTIVE

ONLY, AND INDICATE TYPE AND QUALITY TO BE PROVIDED. ALL

REFERENCES TO BRAND OR MANUFACTURER NAMES SHALL BE

INTERPRETED TO INCLUDED THE LANGUAGE "OR A/E

APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING

SPECIFICATIONS WILL BE CONSIDERED. IRRESPECTIVE OF THE

LANGUAGE "OR A/E APPROVED EQUAL" APPEARING IN

CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.

TE

XA

S D

EP

AR

TM

EN

T O

F C

R

IM

IN

AL

J U

ST

IC

E W

AL

LA

C E

PA

C

K U

N

IT

R

EP

LA

C

E R

O O

F

- M

U

LT

IP

LE

B

LD

G S.

N

AV

AS

O

TA

, T

EX

AS

J.R.,D.V, R.S.

09/24/2025

ISSUED FOR PROPOSAL

696-FD-27-P002 14 of 47

M

M2

X

W

Y Z

AA

G G2

Q

R

B

A

N

N1

T

U

S

J

M3

WING D

WING C

WING B

WING A

RESTRICTION

HOUSING

ADMINISTRATION

FOOD

SERVICE

INFIRMARY

EDUCATION

LAUNDRY

GYM

N.I.C.

N.I.C.

N.I.C.

BB

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

WING E

HALLN.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

HALL H

HALL G

HALL A

HALL B

HALL C

HALL D

D1 N.I.C.

J

H

E1

E2

E3

E4

E5

E6

E7

E14

E13

E12

E11

E10

E9

E8

WING D

WING C

HALL D

EF EF EF EF EF EF

EF EF EF EF EF EF

EF

SP

SP

EF

EF

EF

EF EF EF EF EF

EF EF EF EF EF

EF

SP SP

EF

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

DS DS

DS DS

SB SB

SBSB

WALL LIGHTWALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

WALL LIGHT

GUTTER

GUTTER

SPEAKER

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

SB

DS

WALL LIGHTWALL LIGHT

D1 N.I.C.

SL

SL

SL

SL

SL

SL

SL

SL

HALL C

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP.

D1

TYP. D1

TYP.

D1

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D2

TYP.

D3

TYP.

D3

TYP.

D4

TYP.

D4

TYP.

WING B

10 11 12 13

14 10 11 12 13

RIDGERIDGE

RIDGERIDGE

1 2 3 4 5 6

CABLE BRACING SEE

STRUCT. DRAWINGS TYP.

8 TYP.

LADDER, TYP.

SLSL

LADDER, TYP.

LADDER, TYP.

SL

SL

LADDER, TYP.

10 11 12 13

151 4 5 6

141414

10 11 12 13

810 11 12 13

TYP.

10 11 12 13 8

TYP. 9

R

ID

G E

141414 7

CABLE BRACING SEE

STRUCT. DRAWINGS TYP.

10 11 12 13

10 11 12 13

1 2 3 4 5 6

10 11 12 13

10 11 12 13

1 4 5 6

R

ID

G E

P.YA MAY 17, 2012

N0APPROVEDM

T0NE,

D W. S

TEXAS BOARD

EXAMINERS

TO PRACTICE

ARCHITECTURE

ARCHITECTURAL

R

E.

OF

BY THE

a m te ch so lu tio ns , i nc

AS NOTED

ROOF PLAN WING C, HALL C, WING D, AND

HALL D - CONSTRUCTION

R1

WING D, AND HALL D - CONSTRUCTION

1/16"=1'-0"SCALE:

EF

SP

EXHAUST FAN

SOIL PIPE

SYMBOL LEGEND

TAPER LINE

SCUPPER / OVERFLOWSC/OSC

DOWNSPOUT

SB SPLASH BLOCK

DS

WALK WAY

KEY PLAN

NORTH

LEGEND

BASE BID

NOT IN CONTRACT (N.I.C.)

NORTH

C.C.G.

KA

TY

F

R

EE

W

AY

, S U

IT

E

#2

H O

U

ST

O N

, T

EX

AS

t

3.

6.

ROOF PLAN WING C, HALL C,

NOT IN CONTRACT (N.I.C.)

LEGEND

CONSTRUCTION NOTES (DOES NOT APPLY TO WING E AND ROOF AREAS E1 – E14):

1 PROVIDE AND INSTALL TEMPORARY SHORING AND SUPPORTS TO PROPERLY ENSURE THE STRUCTURAL INTEGRITY OF THE BUILDING IS NOT COMPROMISED DURING CONSTRUCTION OF THE NEW METAL ROOF PANEL SYSTEM AND METAL WALL AND SOFFIT PANEL SYSTEMS, INCLUDING BUT NOT LIMITED TO REPLACEMENT OF DAMAGED WALL GIRTS, DAMAGED ROOF PURLINS, DAMAGED SECONDARY BRACING, AND FASTENERS, MECHANICAL EQUIPMENT REPLACEMENT, THEN REMOVE TEMPORARY SHORING AND SUPPORTS AFTER THE STRUCTURAL

INTEGRITY OF THE BUILDING HAS BEEN RESTORED

2 INSTALL NEW WALL GIRTS AND NEW SECONDARY BRACING AT SELECT LOCATIONS AS SHOWN ON STRUCTURAL DRAWINGS 3 INSTALL NEW ROOF PURLINS AND NEW SECONDARY BRACING AT SELECT LOCATIONS AS SHOWN ON STRUCTURAL DRAWINGS 4 INSTALL NEW 4” THICK STRUCTURAL INSULATION WITH TAPED SHIP-LAP JOINTS (TOP AND BOTTOM), R-VALUE = R-30 AND MECHANICALLY

ATTACH TO EXISTING METAL BUILDING FRAMING

5 INSTALL SELF-ADHERED UNDERLAYMENT, SHINGLE FASHION TO SHED WATER, OVER STRUCTURAL INSULATION 6 INSTALL NEW 24 GAUGE, 24” WIDE, 2-3/4” TALL TRAP-TEE TRAPEZOIDAL ROOF PANEL SYSTEM, INCLUDING BUT NOT LIMITED TO CLIPS, FASTENERS, FULLY WELDED MECHANICAL CURBS, AND ROOF FLASHINGS

7 REPLACE OR EXTEND EXISTING PIPE AND HOT STACK PENETRATIONS AS REQUIRED TO INSTALL NEW METAL ROOF SYSTEM 8 INSTALL NEW PRE-FINISHED METAL GUTTERS, AND DOWNSPOUTS, AND CONCRETE SPLASH BLOCKS 9 INSTALL NEW ROOF MOUNTED WALKWAY SYSTEM, MECHANICALLY ATTACHED TO EXISTING METAL BUILDING FRAMING, INCLUDING BUT NOT

LIMITED TO ROOF FLASHINGS, AND FASTENERS

10 INSTALL 2 1/2” THICK STRUCTURAL INSULATION WITH TAPED TONGUE AND GROOVE JOINTS (TOP AND BOTTOM), R- VALUE = R-18.75 PLUS

WALL PANEL AIR SPACE R=0.87 FOR TOTAL WALL R=19.62, MECHANICALLY ATTACHED TO EXISTING EXTERIOR WALL FRAMING, INCLUDING

BUT NOT LIMITED TO TRIM, CLIPS, FASTENERS, AND SEALANT

11 INSTALL SELF-ADHERED UNDERLAYMENT, SHINGLE FASHION TO SHED WATER, OVER STRUCTURAL INSULATION 12 INSTALL NEW 24 GAUGE, 12” WIDE, 1-1/2” TALL, INVERTED PLANK PROFILE METAL WALL PANELS WITH CONCEALED FASTENERS, INCLUDING

BUT NOT LIMITED TO CLIPS, TRIM, FASTENERS, GASKETS, AND SEALANT

13 INSTALL NEW 24 GAUGE, 12” WIDE, 1-1/2” TALL, FLAT PROFILE METAL SOFFIT PANELS WITH CONCEALED FASTENERS, INCLUDING BUT NOT

LIMITED TO CLIPS, TRIM, FASTENERS, GASKETS, AND SEALANT

14 INSTALL ROOF MOUNTED MECHANICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO ELECTRICAL AND PLUMBING APPURTENANCES, AS

SHOWN ON MECHANICAL DRAWINGS

15 INSTALL NEW WALL MOUNTED LIGHT ABOVE LIGHT FIXTURE AS SHOWN ON ELECTRICAL DRAWINGS 16 INSTALL TUFF WRAP INTERIOR PROTECTION SYSTEM TO COLLECT ROOFING DEBRIS DURING CONSTRUCTION OPERATIONS AND MAINTAIN

ACTIVE VENTILATION. UPON COMPLETION OF CONSTRUCTION REMOVE AND DISPOSE OR DEBRIS.

RTU/MAU ROOF TOP UNIT/

MAKE-UP HANDLER UNIT

BRAND OR MANUFACTURE'S REFERENCES AREA DESCRIPTIVE

ONLY, AND INDICATE TYPE AND QUALITY TO BE PROVIDED. ALL

REFERENCES TO BRAND OR MANUFACTURER NAMES SHALL BE

INTERPRETED TO INCLUDED THE LANGUAGE "OR A/E

APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING

SPECIFICATIONS WILL BE CONSIDERED. IRRESPECTIVE OF THE

LANG…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .