This is a technical drawing specification document for Walworth County Department of Public Works in Elkhorn, Wisconsin, detailing a motor-operated rolling door system for a salt shed facility. The project involves the furnishing and installation of a NEMA 4X motor-operated rolling door with integrated safety and control features. The door specifications include a 30'-6" opening width, 33'-2" overall height, and 19'-9" door opening height, constructed of galvanized steel with GalvaNex coating in gray finish. The motor system includes a totally enclosed non-ventilated (TENV) motor, reversing magnetic controller, spur gear box, electric brake, auxiliary chain operator, and a transformer with 24-volt control secondary. Control components specified include two push button stations (one NEMA 1 and one NEMA 4X), a wireless sensing edge kit, an electric sensing edge, a UL325 light curtain, and associated safety monitoring modules. The drawing, dated May 12, 2026, with revisions through June 5, 2025, was prepared by John K with drawing number E 02188112 001 B.

The structure supporting the door system must be designed to accommodate a 4,304-pound static load, with materials specified as hot-dip galvanized structural steel per ASTM A 123. Assembly fasteners include Grade 8 hex head cap screws, hex head nuts, hardened flat washers, and hex head lag screws, with critical spacing requirements to maintain factory-set guide gaps essential for proper door operation and wind load resistance. Installation requires a minimum 16-inch clearance in front of the motor for control access, and electrical current specifications must be verified in writing before manufacturing begins. The door's coil is mounted on the exterior side of the building and may be exposed to weather conditions.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ELECTRICAL EQUIPMENT LIST:MOTOR SPECIFICATIONS:

LRG_STDR

SPRING

ADJUSTOR

ELEVATION (COIL SIDE) AND SECTION VIEW

See drawing # for guide detail.

MATERIAL & FINISH:

QUANTITY & MARK:

Hood -

Plain Steel -

Curtain -

Guides -

Bottom Bar -

O

PE

N

IN

G H

EI

G

H T

O

VE

R

AL

L D

O O

R H

EI

G

H T

D O

O R

O

PE

N

IN

G H

EI

G

H T

# GA. INTERLOCKING SLATS

ROLLING DOOR

DISTANCE BETWEEN GUIDES

OPENING WIDTH

MECH COVER

"SUPPORT TO RUN TO TOP OF COIL"

MOTOR COVER

EXTERIOR SLOPED

HOOD

3"

SOLID WALL CONSTRUCTION REQ'D

FOR PROVIDED HOOD SUPPORT(S)

BETWEEN EACH HOOD SECTION

(2) SECTION

1-1/2" TOP HOOD BEAD

FLARED FOR CAULKING

REVISION DATE BY

ORIGINAL DRAWING

JOB:

MODEL # : JOB #:

DEALER*:

CONTRACTOR:

ARCHITECT:

PRODUCT CODE:

â

* "Dealer" refers to any purchaser, customer, or reseller of CornellCookson products, and not necessarily an authorized CornellCookson dealer.

SGH NEMA 4X MOTOR

OPERATED ROLLING DOOR

STOPPERS

HP motor to include a totally enclosed non-ventilated (TENV) motor removable without resetting of limit switches, reversing magnetic controller in NEMA 4X enclosure, spur gear box for drive reduction, electric brake and an auxiliary chain operator. Includes magnetic contactors, UL listed thermal overload protection, rotary limit switches, safety edge circuit and transformer with 24 volt control secondary, delay on reverse, and a door closing warning signal. Pre-wired to a terminal block using color coding of the wires to facilitate troubleshooting. A minimum clearance of 16” in front of motor is required for control access.

CURRENT CHARACTERISTICS:

HZV PH

Electrical current must be verified in writing before job is released for manufacture; current verified and found correct.

Operator bracket bracing required, unless operator is wall mounted.

Signed:

FLA

BOTTOM BAR LOCKING:

None

NOTE: COIL IS MOUNTED ON THE EXTERIOR SIDE OF THE

BUILDING AND MAY BE EXPOSED TO WEATHER1/2"1/2"

WIRELESS

TRANSMITTER

(FIELD MOUNTED)

WIRELESS RECEIVER

(FIELD MOUNTED)

SENSING EDGE

AUXILIARY

HAND CHAIN

2"

14 3/8"±

03-17-2026

'-6

3.9460

MFO 5F 20GP

05/12/26 JOHNK

E 2188112 001 B

ELKHORN, WI

WALWORTH COUNTY DPW SALT SHED

(001)

Galvanized steel with GalvaNex™ coating system.

Finish color: Gray

CORNELLCOOKSON A.D.S.

Structural steel, hot dip galvanized per ASTM A 123

Galvanized steel with GalvaNex™ coating system.

Finish color: Gray

MK:001

Hot dip galvanized per ASTM A 123

Structural steel, hot dip galvanized per ASTM A

ESD10

(**Ultra Powder Coat Slats**)

E 02188112 001 A

6 3/4"

7 3/4"±

19'-10"

19'-9"

9 3/4"±

6 3/4"

23 3/4"

'-6

9"

'-2

1 - Three button push button station `OPEN-CLOSE-STOP` in NEMA 1 enclosure, surface mounted.

1 - Three button push button station `OPEN-CLOSE-STOP` in NEMA 4X enclosure, MMTC 3B4X, flush mounted.

1 - Module GW40-05-1(Reqd w/ (2) monitored entrapment devices) 1 - Y Connector wiring harness #ADA-DA111-WH001.

1 - Telco UL325 light curtain.

1 - Electric sensing edge.

1 - Smartsync wireless, failsafe sensing edge kit.

COIL SIDE

EXTERIOR

MTR.AMP

GID.SCLR.LT

SIDE.CLR.ADJ

SL.GA

DBG

PROPEN

SIDE.CLR.OPR

GID.SCLR.RT

HOD.TOP.DIM

COL.SZ

COH

UPS

OAH

Joseph Latocha Cross-Out

G224A - 4 1/4"

PLAN OF OPENING

SERVICE DOOR GUIDE ASSEMBLY

4-1/4" PACKOFF

SD1_425

AT ON CENTER

ASSEMBLY FASTENERS:

G224A - 4 1/4"

AT ON CENTER

ASSEMBLY FASTENERS:

DISTANCE BETWEEN GUIDES

OPENING WIDTH

1/4" STEEL BRACKET PLATE ABOVE

2 5/8" 1 1/4"

1 5/8"

4 1/4"

1/2"

1 1/8"

3" x 2" x 3/16"

3" x 3 1/2" x 1/4"

6 1/4"

7 1/4"

2 1/2"

1/2"

6 1/4"

7 1/4"

2 1/2"

2 5/8" 1 1/4"

1 5/8"

4 1/4"1 1/8"

3" x 2" x 3/16"

WALL FASTENERS: WALL FASTENERS:

AT ON CENTER AT ON CENTER

INSTALLERS NOTE:

MAINTAINING FACTORY SET GUIDE GAPS IS CRITICAL

TO THE PROPER OPERATION OF THE DOOR AND IT'S

ABILITY TO WITHSTAND THE DESIGNED WINDLOAD!

ENDLOCK DETAIL

NOTE: Wall construction detail shown is for illustrative purposes only, does not imply compliance with building requirements, and must meet architectural specifications to properly support product. Products designed with wind load requirements must be properly fastened to structural members as specified in order to avoid catastrophic failure. Wall construction and closure installation shall be in accordance with the local authority having jurisdiction requirements.

3 1/2" x 3 1/2" x 1/4"3 1/2" x 3 1/2" x 1/4"

REVISION DATE BY

ORIGINAL DRAWING

JOB:

MODEL # : JOB #:

DEALER*:

CONTRACTOR:

ARCHITECT:

PRODUCT CODE:

â

* "Dealer" refers to any purchaser, customer, or reseller of CornellCookson products, and not necessarily an authorized CornellCookson dealer.

- Ø3/8-16 x 1-1/2"- Ø3/8-16 x 1-1/2" - Ø3/8"- Ø3/8" HEX HEAD CAP SCREW, GR. 8

- HEX HEAD NUT, GR. 8

- HARDENED FLAT WASHERS

HEX HEAD CAP SCREW, GR. 8

- HEX HEAD NUT, GR. 8

- HARDENED FLAT WASHERS

- HEX HEAD LAG SCREW- HEX HEAD LAG SCREW

x 2" x 2"

3/4" 2 5/8"

CP0020

EXTERIOR

COIL

SENSING

EDGE

2" 2"

BOTTOM BAR / SLAT DETAIL

CP1443 MOLDED NYLON ENDLOCK

ON ALTERNATING SLATS WITH

2 x 1/4" RIVETS

CP1443

1 1/2" (TYP.)

LIGHT CURTAIN

(TYP.)

06-05-2025

STRUCTURE MUST BE

DESIGNED TO SUPPORT

4304 LBS STATIC LOAD

MFO 5F 20GP

05/12/26 JOHNK

MK:001

ELKHORN, WI

WALWORTH COUNTY DPW SALT SHED

CORNELLCOOKSON A.D.S.

ESD10 E 2188112 001 B

24" 24"

19'-10"

19'-9"

24" 24"

WLFSTSPCNGMAXL

ASYFSTSPCNGMAXL

DBG

PROPEN

WLFSTSPCNGMAXR

ASYFSTSPCNGMAXR

Sheets and Views
02188112_001A-Model
02188112_001B-Model

File details come from the government source that posted it. Updated .