Summary
This is a set of construction drawings for the Harford Waste Disposal Center Landfill Gas Expansion project located at 3241 Scarboro Road, Street, Maryland 21154, prepared by EA Engineering, Science, and Technology, Inc. for the Harford County Department of Public Works and Maryland Environmental Service. The project scope includes the installation of six condensate drains, four caisson wells, and twelve landfill gas extraction wells at existing Cells N1 and N2 at interim cell conditions to maintain compliance with new state regulations. The drawings depict both interim condition installations and final condition installations (marked as "not in contract"), with detailed specifications for well depths, piping configurations, wellhead assemblies, and collection system layouts. The interim condition work requires installation of traditional and caisson-type extraction wells with depths varying from approximately 19 to 64 feet, utilizing 6-inch HDPE SDR17 perforated pipe for extraction and 4-inch to 8-inch diameter HDPE piping for gas collection headers and laterals. The county maintains the option to install landfill gas header and lateral collection piping at grade rather than buried to facilitate future maintenance and operations.
The construction drawings establish specific technical requirements for all materials, including HDPE pipe specifications (SDR 17 rating, 3408 type resin, heat-fusion jointing), valve specifications (Type 57 butterfly valves by Asahi/America), and wellhead assemblies (QED Environmental Systems Model ORP215 quick-change orifice plate design rated for 0-50 SCFM flow). The contractor is responsible for surveying existing grade conditions, staking well locations, obtaining all required permits except where noted, maintaining site operations within established hours, and providing as-built documentation within 30 days of completion. Work must conform to the MDE Refuse Permit No. 2022-WMF-0570, coordinate with existing landfill operations to maintain access and prevent interference, and comply with all applicable OSHA regulations and Harford County Department of Public Works standard specifications. The design includes provisions for future well extension during subsequent filling operations and potential well abandonment as directed by the county.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2-1-26-4-63-5 Solicitation Documents.pdf | ||
| 1-1-26-4-63-5 Bidding Documents.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VICINITY MAP
SCALE: 1" = 2 MILES
SITE LOCATION MAP
SCALE: 1" = 2,000'
CELL N1
SCARBORO R
D
SCALE AS SHOWN
FI
LE
P
AT
H : Q
:\P R
O
JE
C
TS
\1
H
W D
C L
FG
E
XP
AN
SI
O
N \C
AD
\P
R O
D U
C
TI
O N
\D
ES
IG
N
S
ET
\1
H
W D
C L
FG
E
XP
AN
SI
O
N
PL
AN
SE
T.
D W
G [G
-0
] S U
LT
AN
A, S
H
AR
M
IN
/3
0/
:5
PM
PROFESSIONAL CERTIFICATION. I HEREBY CERTIFY THAT
THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME,
AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF MARYLAND,
LICENSE NO. 36798
EXPIRATION DATE: 01-19-2027
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
R
EA Engineering, Science, and Technology, Inc., PBC www.eaest.com
OF 10
G-001
MD83F
NAVD88
3241 SCARBORO ROAD
STREET, MARYLAND 21154
HARFORD WASTE DISPOSAL
CENTER
LANDFILL GAS EXPANSION
DESIGN
DRAWN BY: DPA DESIGNED BY: SS
CHECKED BY: SMD/GAT PROJECT MANAGER: LJO
PROJECT NUMBER: 1577623
DATE: APRIL 2026 SHEET:
DRAWING NO.
DRAWING INFORMATION
DRAWING TITLE
PROJECT ADDRESS
PROJECT NAME
SEAL
REVISIONS
225 Schilling Circle, Suite 400 Hunt Valley, Maryland 21031
(410) 584-7000
FULL SIZE PLOT: 24" x 36"
HORIZONTAL DATUM:
VERTICAL DATUM:
HARFORD WASTE DISPOSAL CENTER
LANDFILL GAS EXPANSION DESIGN
HARFORD COUNTY
3241 SCARBORO ROAD - STREET, MARYLAND 21154
SHEET LIST
SHEET
NO. DRAWING NO. DRAWING TITLE
1 G-001 TITLE SHEET
2 G-002 GENERAL NOTES & LEGEND
3 C-101 EXISTING CONDITIONS PLAN
4 C-102 PROPOSED LFG EXTRACTION WELL LAYOUT INTERIM CONDITION
5 C-103 PROPOSED LFG EXTRACTION WELL LAYOUT FINAL CONDITION
- NOT IN CONTRACT
6 C-501 LFG EXTRACTION WELL DETAILS INTERIM CONDITION
7 C-502 LFG EXTRACTION WELL DETAILS INTERIM CONDITION
8 C-503 LFG EXTRACTION WELL DETAILS FINAL CONDITION - NOT IN CONTRACT
9 C-504 LFG EXTRACTION WELL DETAILS FINAL CONDITION - NOT IN CONTRACT
10 C-505 LFG EXTRACTION WELL DETAILS FINAL CONDITION - NOT IN CONTRACT
ENGINEER'S CERTIFICATION
I HEREBY CERTIFY THAT THIS PLAN HAS BEEN PREPARED BY ME, OR
UNDER MY SUPERVISION, AND MEETS THE MINIMUM STANDARDS OF THE
HARFORD COUNTY DEPARTMENT OF PUBLIC WORKS AND/OR THE UNITED
STATES DEPARTMENT OF AGRICULTURE, SOIL CONSERVATION SERVICE,
AND/OR THE MARYLAND DEPARTMENT OF THE ENVIRONMENT, WATER
MANAGEMENT ADMINISTRATION.
SIGNED:
PRINT NAME: Laura Jo Bertrand Oakes
DATE:
P.E. NO.: 36798
DEVELOPER'S/LANDOWNER'S CERTIFICATION
I/WE HEREBY CERTIFY THAT ALL PROPOSED WORK SHOWN ON THESE
CONSTRUCTION DRAWING(S) WILL BE ACCOMPLISHED PURSUANT TO
THESE PLANS. I/WE ALSO UNDERSTAND THAT IS IS MY/OUR
RESPONSIBILITY TO HAVE THE CONSTRUCTION SUPERVISED AND
CERTIFIED, INCLUDING THE SUBMITTAL OF "AS-BUILT" PLANS WITHIN 30
DAYS OF COMPLETION, BY A REGISTERED PROFESSIONAL ENGINEER.
SIGNED:
PRINT NAME:
DATE:
AS-BUILT CERTIFICATION
I HEREBY CERTIFY THAT THE FACILITY SHOWN ON THIS PLAN WAS
CONSTRUCTED AS SHOWN ON THE "AS-BUILT" PLANS AND MEETS THE
APPROVED PLAN SPECIFICATIONS.
SIGNED:
PRINT NAME:
DATE:
P.E. NO.:
CERTIFY MEANS TO STATE OR DECLARE A PROFESSIONAL OPINION
BASED UPON ON-SITE INSPECTIONS AND MATERIAL TESTS WHICH
ARE CONDUCTED DURING CONSTRUCTION. THE ON-SITE
INSPECTIONS AND MATERIAL TESTS ARE THOSE INSPECTIONS AND
TESTS DEEMED SUFFICIENT AND APPROPRIATE BY COMMONLY
ACCEPTED ENGINEERING STANDARDS. CERTIFY DOES NOT MEAN
OR IMPLY A GUARANTEE BY THE ENGINEER NOR DOES AN
ENGINEER'S CERTIFICATION RELIEVE ANY OTHER PARTY FROM
MEETING REQUIREMENTS IMPOSED BY CONTRACT, EMPLOYMENT,
OR OTHER MEANS, INCLUDING MEETING COMMONLY ACCEPTED
INDUSTRY PRACTICES.
DESCRIPTION OF WORK
THIS DESCRIPTION OF WORK IS INTENDED TO ASSIST THE
CONTRACTOR IN UNDERSTANDING THE BASIC REQUIREMENTS OF THE
CONTRACT. THE DESCRIPTION OF WORK IS NOT INTENDED TO DEFINE
THE COMPLETE REQUIREMENTS OF THE CONTRACT. A COMPLETE
REVIEW OF THE CONTRACT DRAWINGS IS REQUIRED TO FULLY
UNDERSTAND ALL CONTRACT REQUIREMENTS. THE WORK INCLUDES
INSTALLATION OF SIX (6) CONDENSATE DRAINS, FOUR (4) CASSION
WELLS, AND TWELVE (12) LANDFILL GAS EXTRACTION WELLS AT THE
EXISTING CELLS N1 AND N2 ELEVATIONS (INTERIM CELL CONDITION,
NOT FINAL PERMITTED GRADE) TO REMAIN IN COMPLIANCE WITH NEW
STATE REGULATIONS. FOR EASE OF INSTALLATION AND MAINTENANCE,
THE COUNTY MAY ELECT TO INSTALL LANDFILL GAS HEADER AND
LATERAL COLLECTION PIPING AT GRADE.
TITLE SHEET
CELL N2
CELLS A-J
DUBLIN RD
CONOWINGO RD
(RTE 1)
SITE
5/4/2026
Sharmin Sultana Stamp jtschoenberger Text Box Jeffrey T. Schoenberger jtschoenberger Text Box 5/6/2026
SCALE AS SHOWN
FI
LE
P
AT
H : Q
:\P R
O
JE
C
TS
\1
H
W D
C L
FG
E
XP
AN
SI
O
N \C
AD
\P
R O
D U
C
TI
O N
\D
ES
IG
N
S
ET
\1
H
W D
C L
FG
E
XP
AN
SI
O
N
PL
AN
SE
T.
D W
G [G
-0
] S U
LT
AN
A, S
H
AR
M
IN
/3
0/
:5
PM
PROFESSIONAL CERTIFICATION. I HEREBY CERTIFY THAT
THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME,
AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF MARYLAND,
LICENSE NO. 36798
EXPIRATION DATE: 01-19-2027
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
R
EA Engineering, Science, and Technology, Inc., PBC www.eaest.com
OF 10
G-002
MD83F
NAVD88
3241 SCARBORO ROAD
STREET, MARYLAND 21154
HARFORD WASTE DISPOSAL
CENTER
LANDFILL GAS EXPANSION
DESIGN
DRAWN BY: DPA DESIGNED BY: SS
CHECKED BY: SMD/GAT PROJECT MANAGER: LJO
PROJECT NUMBER: 1577623
DATE: APRIL 2026 SHEET:
DRAWING NO.
DRAWING INFORMATION
DRAWING TITLE
PROJECT ADDRESS
PROJECT NAME
SEAL
REVISIONS
225 Schilling Circle, Suite 400 Hunt Valley, Maryland 21031
(410) 584-7000
FULL SIZE PLOT: 24" x 36"
HORIZONTAL DATUM:
VERTICAL DATUM:
SITE ADDRESS
3241 SCARBORO ROAD
STREET, MARYLAND 21154
OWNER
HARFORD COUNTY DEPARTMENT OF PUBLIC WORKS
212 S. BOND STREET
BEL AIR, MARYLAND 21014
CONTACT: JEFFERY T. SCHOENBERGER, P.E.
410-638-3285
OPERATOR
MARYLAND ENVIRONMENTAL SERVICE
3135 SCARBORO ROAD
STREET, MARYLAND 21154
CONTACT: JEFFREY R. LANDIS, P.E.
410-638-3018
GENERAL NOTES:
1. EXISTING CONTOURS DEPICTING EXISTING CONDITIONS ARE BASED ON AN AERIAL SURVEY
CONDUCTED BY THE BAI GROUP, LLC. (BAI) ON 20 DECEMBER 2023. EXISTING CONTOURS
REPRESENT EXISTING CELLS N1 AND N2 ELEVATIONS (INTERIM CELL CONDITION, NOT
PERMITTED FINAL GRADE). THE COUNTY MAY PURSUE ADDITIONAL FILLING IN THE FUTURE TO
FINAL CELL N1/N2 CLOSURE GRADES IN ACCORDANCE WITH THE CELL N2 CONSTRUCTION AND
CELLS A-J CLOSURE DESIGN BY EA ENGINEERING (MARCH 2014).
2. CELL N1 LINER GRADES USED FOR EXTRACTION WELL DESIGN DEPTHS BASED ON AS-BUILT
LOW PERMEABILITY SOIL LAYER SURVEY CONDUCTED BY MORRIS AND RITCHIE ASSOCIATES,
INC. (MRA) (CONTOURS NOT SHOWN).
3. CELL N2 LINER GRADES USED FOR EXTRACTION WELL DESIGN DEPTHS BASED ON AS-BUILT
LOW PERMEABILITY SOIL LAYER SURVEY CONDUCTED BY MORRIS AND RITCHIE ASSOCIATES,
INC. (MRA) IN 2015 (CONTOURS NOT SHOWN).
4. FINAL CELL N1/N2 CLOSURE GRADES PER THE CELL N2 CONSTRUCTION AND CELLS A-J
CLOSURE DESIGN BY EA ENGINEERING (MARCH 2014), AS APPROVED AND PERMITTED BY MDE
IN 2014 (CONTOURS SHOWN ON FINAL CONDITION).
5. FOR CELL N1, ADDITIONAL SURVEY FOR LINER GRADES BASED ON AS-BUILT LINER SURVEY
CONDUCTED BY MORRIS AND RITCHIE ASSOCIATES, INC. (MRA) IN 2013 WAS UTILIZED IN
EXTRACTION WELL PLACEMENT AND DESIGN (CONTOURS NOT SHOWN).
6. ALL WORK ON THIS PROJECT SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS SET
FORTH BY THE MOST RECENT HARFORD COUNTY DEPARTMENT OF PUBLIC WORKS STANDARD
SPECIFICATIONS FOR CONSTRUCTION AND MATERIALS, UNLESS SPECIFIED OTHERWISE.
7. ALL CONSTRUCTION OPERATIONS SHALL BE ACCOMPLISHED IN ACCORDANCE WITH
APPLICABLE STATE AND LOCAL STATUTES AND U.S. OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION (OSHA) REGULATIONS. COPIES OF OSHA'S STANDARDS MAY BE PURCHASED
FROM THE U.S. GOVERNMENT PRINTING OFFICE. THE CONTRACTOR ALONE SHALL BE
RESPONSIBLE FOR THE EXECUTION OF THE WORK IN ACCORDANCE WITH ALL APPLICABLE
HEALTH AND SAFETY REQUIREMENTS. THE OWNER NOR THE ENGINEER SHALL BE
RESPONSIBLE FOR INSPECTION OF THE WORK OR THE METHODS OF CONSTRUCTION FOR
COMPLIANCE WITH THESE REQUIREMENTS.
8. THE 100-YEAR FLOOD PLAIN DOES NOT EXIST WITHIN THE VICINITY OF THE PROPOSED WORK.
9. HORIZONTAL DATUM: NAD83 (MD STATE PLANE); VERTICAL DATUM: NAVD88.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR SURVEY OF EXISTING GRADE AND STAKEOUT OF
PROPOSED EXTRACTION WELL LOCATIONS PRIOR TO WELL INSTALLATION. CONTRACTOR
SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE COMMENCING WORK. IT IS
THE CONTRACTOR'S RESPONSIBILITY TO REPORT ANY DISCREPANCIES TO ENGINEER AND
OWNER IN A TIMELY MANNER. FAILURE TO CONDUCT SITE INVESTIGATION ADVANCE OF WORK
OR VERIFY DIMENSIONS SHALL NOT BE CAUSE FOR ADDITIONAL COSTS TO THE OWNER.
11. PIPE ELEVATIONS ARE INVERT ELEVATIONS UNLESS OTHERWISE NOTED.
12. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITS WHICH ARE REQUIRED TO PERFORM
THE WORK PRIOR TO CONSTRUCTION, EXCEPT AS NOTED OTHERWISE IN THE CONTRACT
DOCUMENTS.
13. CONTRACTOR SHALL CONFORM TO THE ISSUED MDE REFUSE PERMIT NO. 2022-WMF-0570 FOR
THE HARFORD WASTE DISPOSAL CENTER (HWDC).
14. CONTRACTOR SHALL CONFINE ALL WORK, INCLUDING ACCESS, STAGING, AND EQUIPMENT
STORAGE TO THE BOUNDARIES SHOWN HEREIN.
15. CONTRACTOR SHALL CONDUCT CONSTRUCTION DURING REGULAR OPERATING HOURS FOR
THE HWDC. CONTRACTOR AND CONTRACTOR'S EMPLOYEES SHALL LEAVE THE SITE
IMMEDIATELY AT THE END OF THEIR SHIFT. IF PUMPS, GENERATORS, ETC. NEED TO BE RUN
AT NIGHT, NOISE ATTENUATION WILL BE REQUIRED.
16. CONTRACTOR SHALL CONDUCT EQUIPMENT MAINTENANCE ONLY WITHIN THE
AFOREMENTIONED PERMITTED HOURS OF CONSTRUCTION. CONTRACTOR SHALL
IMMEDIATELY CLEAN UP ANY SPILLS AND CONTAMINATED SOIL, STONE, ETC. AND SHALL BE
IMMEDIATELY COLLECTED AND DISPOSED OF BY THE CONTRACTOR (WITH MANIFESTS).
CONTRACTOR AND CONTRACTOR'S EMPLOYEES SHALL NOT WORK ON PERSONAL VEHICLES
ON SITE.
17. CONTRACTOR SHALL RECYCLE WASTE MATERIAL TO THE MAXIMUM EXTENT PRACTICABLE.
18. THE CONTRACTOR SHALL CONTACT MISS UTILITY AT 1-800-257-7777 AT LEAST 48 HOURS PRIOR
TO DIGGING.
19. APPROXIMATE LOCATION OF EXISTING UTILITIES ARE SHOWN. THE CONTRACTOR SHALL TAKE
ALL NECESSARY PRECAUTIONS TO PROTECT EXISTING UTILITIES AND MAINTAIN
UNINTERRUPTED SERVICE AT ALL TIMES. IF UTILITIES ARE ENCOUNTERED, THE CONTRACTOR
SHALL IMMEDIATELY INFORM THE OWNER AND REPAIR THE UTILITY AT THE CONTRACTOR'S
EXPENSE PRIOR TO CONTINUING WORK.
20. BENCHMARK MONUMENTS AND/OR PROPERTY MARKERS SHALL BE PROTECTED AT ALL TIMES
AND SHALL NOT BE DISTURBED BY CONSTRUCTION ACTIVITIES UNLESS OTHERWISE WAIVED
BY THE COUNTY IN WRITING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACEMENT
OF BENCHMARK MONUMENTS AND/OR PROPERTY MARKERS DAMAGED AS A RESULT OF THE
CONTRACTOR'S ACTIVITIES.
21. FAILURE TO MENTION SPECIFICALLY ANY WORK WHICH WOULD NORMALLY BE REQUIRED TO
COMPLETE THE PROJECT SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH
WORK.
22. CONTRACTOR SHALL NOT INTERFERE WITH LANDFILL OPERATIONS. ACCESS TO CELL N1/N2, CELLS A-J, AND LEACHATE MANAGEMENT FACILITIES SHALL BE MAINTAINED DURING ALL
FACILITY OPERATING HOURS.
23. CONTRACTOR SHALL PROVIDE AS-BUILT SURVEY OF INSTALLED GAS WELLS AND "RED LINE"
CONTRACT DRAWINGS NOTING CHANGES AS AS-BUILT CONDITIONS.
GENERAL NOTES & LEGEND
LEGEND
DESCRIPTION EXISTING PROPOSED
EXTRACTION WELL
LANDFILL GAS HEADER
LANDFILL GAS LATERAL
MAJOR CONTOUR
MINOR CONTOUR
ANCHOR TRENCH
LANDFILL GAS VERTICAL TEE
ISOLATION VALVE
CONDENSATE DRAINS
EW-N1-X
NA
NA
NA
LFG LFG LFG LFG
LANDFILL GAS NOTES AND SPECIFICATIONS:
1. INSTALL LANDFILL GAS WELLS PER CONTRACT DRAWINGS.
2. LANDFILL GAS EXTRACTION WELLS MAY NEED TO BE EXTENDED VERTICALLY DURING FUTURE FILLING
OPERATIONS OR ABANDONED, AS DIRECTED BY THE COUNTY.
3. CONTRACTOR MAY MAKE MINOR ADJUSTMENTS TO LANDFILL GAS HEADER ALIGNMENT PROVIDED A
MINIMUM 3% SLOPE IS MAINTAINED ALONG THE ENTIRE LENGTH OF THE PIPE ALIGNMENT.
CONTRACTOR MAY FIELD ADJUST NUMBERS, PLACEMENT, AND ANGLE OF BENDS AS LONG AS
MINIMUM SLOPE, POSITIVE DRAINAGE OF COLLECTION LOOPS, WELL PLACEMENT, AND DEPTH OF
COVER IS MAINTAINED.
4. LANDFILL GAS COLLECTION SYSTEM WELLHEADS SHALL BE A QUICK-CHANGE ORIFICE PLATE DESIGN, MODEL ORP215 BY QED ENVIRONMENTAL SYSTEMS, INC., AND SHALL CONSIST OF WELL HEAD PIPING
AND FITTINGS, FLOW CONTROL VALVE, GAS TEMPERATURE GAUGE PORT, QUICK CONNECT GAS
SAMPLING, STATIC AND DIFFERENTIAL PORTS, REINFORCED FLEXIBLE HOSE CONNECTOR, AND DUST
CAP. ALL WELL HEAD PIPING AND FITTINGS SHALL BE SCHEDULE 80 PVC.
5. HDPE PIPE AND FITTINGS SHALL BE STANDARD DIMENSIONS RATING (SDR) 17 HDPE PIPE USING A 3408 TYPE RESIN, OR APPROVED EQUAL. PIPE SHALL BE EXTRUDED FROM A TYPE III, CLASS C, CATEGORY 5, GRADE P34 COMPOUND AS DESCRIBED IN ASTM D 1248. IT SHALL BE CLASSIFIED AS CELL 345434C
ACCORDING TO ASTM D 3350 AND HAVE THE MATERIAL DESIGNATION OF PE 3408.
6. HDPE PIPE SHALL BE JOINED BY HEAT FUSION TO PROVIDE A HOMOGENEOUS, SEALED AND LEAK
PROOF JOINT. PIPE SHALL BE JOINED FOLLOWING MANUFACTURER'S RECOMMENDATION.
POLYETHYLENE PIPE SHALL NOT BE SOLVENT SEALED.
7. PIPE FITTINGS SHALL BE ASTM D-2513-LATEST EDITION, BUTT FUSION MOLDED. FITTINGS SHALL BE
PRESSURE RATED TO MATCH THE SYSTEM PIPING TO WHICH THEY ARE FUSED.
8. FERNCO OR APPROVED FLEXIBLE MECHANICAL COUPLINGS FOR PIPE CONNECTIONS SHALL BE THE
STAINLESS STEEL TYPE SUITABLE FOR USE WITH HDPE PIPE.
9. VALVES SHALL BE TYPE 57 PROVIDED BY ASAHI/AMERICA. INC. OF MALDEN, MA OR APPROVED EQUAL.
LFG TYPE 57 COLLECTION SYSTEM VALVES SHOULD BE PVC BODY WITH POLYPROPYLENE DISCS, AND
NITRILE OR EPDM SEAT AND SEALS. VALVES AND OPERATORS SHALL BE SUITABLE FOR THE
EXPOSURE THEY ARE TO BE SUBJECTED TO, E.G., BURIED AND LANDFILL GAS. VALVES SHALL BE COMPLETE WITH NECESSARY OPERATORS, ACTUATORS, EXTENSION STEMS, FLOOR STANDS, WORM
AND GEAR OPERATORS, OPERATING NUTS, CHAINS, WRENCHES, AND OTHER ACCESSORIES OR
APPURTENANCES WHICH ARE REQUIRED FOR THE PROPER COMPLETION OF THE WORK.
10. OWNER MAY ELECT TO UTILIZE AT GRADE PIPING FOR LATERAL AND HEADER COLLECTION PIPING.
FLEXIBLE EXPANSION COUPLINGS, AS APPROVED BY THE ENGINEER, SHALL BE UTILIZED AT WELL CONNECTIONS AND CHANGES IN PIPE DIRECTION AND SHALL PROVIDE MINIMUM 50% CONTRACTION
AND 20% EXTENSION, OR GREATER IF RECOMMENDED BY PIPE MANUFACTURER.
11. IF PIPING IS INSTALLED AT GRADE, CONTRACTOR SHALL MARK PIPING IN A HIGH VISIBILITY PAINT AND PLACE CONES AT EACH LANDFILL GAS EXTRACTION WELL LOCATION. AT GRADE PIPING SHALL BE STAKED WITH #6 REBAR WITH RUBBER CAP DRIVEN 3' +/- INTO GROUND, OR APPROVED EQUAL.
EROSION AND SEDIMENT CONTROL NOTES:
1. DISTURBANCE IN AREA OF CELLS N1 AND N2 CONSTRUCTION ADDRESSED UNDER THE HWDC SITE OPERATIONS EROSION AND SEDIMENT CONTROL PLAN #59599 PREPARED BY EA ENGINEERING AND
APPROVED IN APRIL 2023.
2. THE CONTRACTOR SHALL PROTECT ALL POINTS OF CONSTRUCTION INGRESS AND EGRESS TO PREVENT
THE DEPOSITION OF MATERIALS OUTSIDE OF WORK AREAS AND ONTO PUBLIC ROADS.
3. WORK AREAS ARE TO BE KEPT FREE OF DEBRIS AT ALL TIMES.
SOIL SPECIFICATIONS:
1. GENERAL FILL SHALL HAVE A MAXIMUM DRY DENSITY OF AT LEAST 100 POUNDS PER CUBIC FOOT AS
DETERMINED BY AASHTO DESIGNATION T-180, METHOD D PROCEDURES AND SHALL BE FREE OF
EXCESS ORGANIC MATERIAL, BOULDERS, SHARP, ANGULAR STONES IN EXCESS OF 2 INCHES OR ROUNDED STONES IN EXCESS OF 3 INCHES. MATERIAL SHALL MEET ASTM D2487, CLASSIFICATION GM, SW, SP, SM.
2. GRANULAR FILL SHALL BE NO. 57 STONE. MATERIAL SHALL BE FREE OF LIMESTONE AND HAVE LESS
THAN 2% FINES.
3. LFG COLLECTION PIPE BEDDING MATERIAL SHALL BE GENERAL FILL, OR APPROVED EQUAL.
LFGL LFGL
EW-N1-X
NOT IN CONTRACT
NOT IN CONTRACT
NOT IN CONTRACT
Sharmin Sultana Stamp
305305
335335
310 310
315 315
320 320
41041
300300
290290 295 295
300 300
305310
310315
320325
325330
330335
0 42
420425 430435
445450
41542
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
EL: 298.00
LFG
LFGLFGLFGLFGLFGLFGLFGLFGLFGLFGLFGLFGLFGLFGLFGLFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG LFG LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LF
G
LF
G
LF
G
LF
G
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LFGLFGLFGLFGLFGLFGLFGLFGLFGLFG
LFGLFGLFG
LFG
LF
G
LF
G
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
EW-N1-4
EW-N1-6
EW-N1-3
EW-N1-2
EW-N1-1
EW-N1-5
EW-N1-7
40541
325330
335340
ACCESS ROAD
ACCESS ROAD
LIMIT OF EX. CELL N1
ANCHOR TRENCH
EX. 12" DIA. LFG
HEADER PIPE
EX. LFG
VERTICAL TEE #4
EX. CONDENSATE DRAIN
(TYP. OF 3)
EX. 4" DIA. LFG
LATERAL PIPE (TYP.)
EX. LFG
EXTRACTION WELL
(TYP. OF 7)
EX. 6" DIA. LFG
HEADER PIPE (TYP.)
N: 720400
E:
N: 720400
E:
N: 719400
E:
N: 719400
E:
EX. 12" DIA. LFG
HEADER PIPE
EX. LFG
VERTICAL TEE #11
8" DIA. EX. LFG
HEADER PIPE (TYP.)
EX. LFG
VERTICAL TEE #13
EX. LFG
VERTICAL TEE #14
EX. LFG
VERTICAL TEE #15
EX. LFG
VERTICAL TEE #1
EX. LFG
VERTICAL TEE #2
EX. LFG
VERTICAL TEE #3
EX. LFG
VERTICAL TEE #5
EX. LFG
VERTICAL TEE #12
EX. LFG
VERTICAL TEE #10
EX. LFG
VERTICAL TEE #8
EX. LFG
VERTICAL TEE #7
EX. LFG
VERTICAL TEE #6
EX. LFG
VERTICAL TEE #9
GRAPHIC SCALE IN FEET
0 25 50 100
FI
LE
P
AT
H : Q
:\P R
O
JE
C
TS
\1
H
W D
C L
FG
E
XP
AN
SI
O
N \C
AD
\P
R O
D U
C
TI
O N
\D
ES
IG
N
S
ET
\1
H
W D
C L
FG
E
XP
AN
SI
O
N
PL
AN
SE
T.
D W
G [C
-1
] S U
LT
AN
A, S
H
AR
M
IN
/3
0/
:5
PM
PROFESSIONAL CERTIFICATION. I HEREBY CERTIFY THAT
THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME,
AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF MARYLAND,
LICENSE NO. 36798
EXPIRATION DATE: 01-19-2027
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
R
EA Engineering, Science, and Technology, Inc., PBC www.eaest.com
OF 10
C-101
MD83F
NAVD88
3241 SCARBORO ROAD
STREET, MARYLAND 21154
HARFORD WASTE DISPOSAL
CENTER
LANDFILL GAS EXPANSION
DESIGN
DRAWN BY: DPA DESIGNED BY: SS
CHECKED BY: SMD/GAT PROJECT MANAGER: LJO
PROJECT NUMBER: 1577623
DATE: APRIL 2026 SHEET:
DRAWING NO.
DRAWING INFORMATION
DRAWING TITLE
PROJECT ADDRESS
PROJECT NAME
SEAL
REVISIONS
225 Schilling Circle, Suite 400 Hunt Valley, Maryland 21031
(410) 584-7000
FULL SIZE PLOT: 24" x 36"
HORIZONTAL DATUM:
VERTICAL DATUM:
EXISTING CONDITIONS PLAN
CELL N1
CELL N2
305305
335335
310 310
315 315
320 320
41041
300300
290290 295 295
300 300
305310
310315
320325
325330
330335
0 42
420425 430435
445450
41542
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
EL: 298.00
LFG
LFGLFGLFGLFGLFGLFGLFGLFGLFGLFGLFGLFGLFGLFGLFGLFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG LFG LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LF
G
LF
G
LF
G
LF
G
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LFGLFGLFGLFGLFGLFGLFGLFGLFGLFG
LFGLFGLFG
LFG
LF
G
LF
G
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
EW-N1-4
EW-N1-6
EW-N1-3
EW-N1-2
EW-N1-1
EW-N1-5
EW-N1-7
40541
325330
335340
ACCESS ROAD
ACCESS ROAD
LIMIT OF EX. CELL N1
ANCHOR TRENCH
EX. 12" DIA. LFG
HEADER PIPE
EX. LFG
VERTICAL TEE #4
EX. CONDENSATE DRAIN
(TYP. OF 3)
EX. 4" DIA. LFG
LATERAL PIPE (TYP.)
EX. LFG
EXTRACTION WELL
(TYP. OF 7)
EX. 6" DIA. LFG
HEADER PIPE (TYP.)
N: 720400
E:
N: 720400
E:
N: 719400
E:
N: 719400
E:
EX. 12" DIA. LFG
HEADER PIPE
EX. LFG
VERTICAL TEE #11
8" DIA. EX. LFG
HEADER PIPE (TYP.)
EX. LFG
VERTICAL TEE #13
EX. LFG
VERTICAL TEE #14
EX. LFG
VERTICAL TEE #15
EX. LFG
VERTICAL TEE #1
EX. LFG
VERTICAL TEE #2
EX. LFG
VERTICAL TEE #3
EX. LFG
VERTICAL TEE #5
EX. LFG
VERTICAL TEE #12
EX. LFG
VERTICAL TEE #10
EX. LFG
VERTICAL TEE #8
EX. LFG
VERTICAL TEE #7
EX. LFG
VERTICAL TEE #6
EX. LFG
VERTICAL TEE #9
LF
G
LF
G
LFG
LFG
LFG
LF
G
LFG
LFG
LFG
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LF
G
LFG
LFG
LF
G
LF
G
LFG LFG
LFGL
LFGL
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LF
G
L
LF
G L
LFGL
LFGL
LF
GL
LF
G
L
LF
G L
LF
G LFG
LFG
LF
G
LFG
LFG
LF
G
LFG
L
LFG
L
LFG
L
LFGL
LFGL
LFGL
LFGL
LF
G
L
LFGL
LFGL
LFGL
LFGL
EW-N2-3
EW-N2-4
EW-N2-11
EW-N1-8
EW-N1-9
EW-N1-10
EW-N1-11
EW-N1-12
EW-N1-13
EW-N1-14
EW-N1-15
EW-N1-16
EW-N1-17
EW-N2-6
EW-N2-5
EW-N1-18
LFGL
LFG
L
LFG
L
LFG
L
CD-N1-4
CD-N1-3
CD-N1-2
CD-N1-1
CD-N1-5
CD-N1-6
TIE-IN WITH EX. LFG
VERTICAL TEE #10
EX. LFG
EXTRACTION WELL
(TYP. OF 7)
TIE-IN WITH EX. LFG
VERTICAL TEE #11
TIE-IN WITH EX. LFG
VERTICAL TEE #8
TIE-IN WITH EX. LFG
VERTICAL TEE #12
TIE-IN WITH EX. LFG
VERTICAL TEE #13
TIE-IN WITH EX. LFG
VERTICAL TEE #1
TIE-IN WITH EX. LFG
VERTICAL TEE #14
TIE-IN WITH EX. LFG
VERTICAL TEE #9
6" DIA LFG HEADER
PIPE (TYP.)
4" DIA LFG LATERAL
PIPE (TYP.)
EX. CONDENSATE DRAIN
(TYP. OF 3)
CELL N1
GRAPHIC SCALE IN FEET
0 25 50 100
FI
LE
P
AT
H : Q
:\P R
O
JE
C
TS
\1
H
W D
C L
FG
E
XP
AN
SI
O
N \C
AD
\P
R O
D U
C
TI
O N
\D
ES
IG
N
S
ET
\1
H
W D
C L
FG
E
XP
AN
SI
O
N
PL
AN
SE
T.
D W
G [C
-1
] S U
LT
AN
A, S
H
AR
M
IN
/3
0/
:5
PM
PROFESSIONAL CERTIFICATION. I HEREBY CERTIFY THAT
THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME,
AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF MARYLAND,
LICENSE NO. 36798
EXPIRATION DATE: 01-19-2027
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
R
EA Engineering, Science, and Technology, Inc., PBC www.eaest.com
OF 10
C-102
MD83F
NAVD88
3241 SCARBORO ROAD
STREET, MARYLAND 21154
HARFORD WASTE DISPOSAL
CENTER
LANDFILL GAS EXPANSION
DESIGN
DRAWN BY: DPA DESIGNED BY: SS
CHECKED BY: SMD/GAT PROJECT MANAGER: LJO
PROJECT NUMBER: 1577623
DATE: APRIL 2026 SHEET:
DRAWING NO.
DRAWING INFORMATION
DRAWING TITLE
PROJECT ADDRESS
PROJECT NAME
SEAL
REVISIONS
225 Schilling Circle, Suite 400 Hunt Valley, Maryland 21031
(410) 584-7000
FULL SIZE PLOT: 24" x 36"
HORIZONTAL DATUM:
VERTICAL DATUM:
PROPOSED LFG EXTRACTION
WELL LAYOUT
INTERIM CONDITION
CELL N2
305305
335335
310 310
315 315
320 320
41041
300300
290290 295 295
300 300
305310
310315
320325
325330
330335
0 42
420425 430435
445450
41542
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
EL: 298.00
40541
325330
335340
ACCESS ROAD
ACCESS ROAD
LIMIT OF EX. CELL N1
ANCHOR TRENCH
EX. 12" DIA. LFG
HEADER PIPE
EX. LFG
VERTICAL TEE #4
N: 720400
E:
N: 720400
E:
N: 719400
E:
N: 719400
E:
EX. 12" DIA. LFG
HEADER PIPE
EX. LFG
VERTICAL TEE #11
8" DIA. EX. LFG
HEADER PIPE (TYP.)
EX. LFG
VERTICAL TEE #13
EX. LFG
VERTICAL TEE #14
EX. LFG
VERTICAL TEE #15
EX. LFG
VERTICAL TEE #1
EX. LFG
VERTICAL TEE #2
EX. LFG
VERTICAL TEE #3
EX. LFG
VERTICAL TEE #5
EX. LFG
VERTICAL TEE #12
EX. LFG
VERTICAL TEE #10
EX. LFG
VERTICAL TEE #8
EX. LFG
VERTICAL TEE #7
EX. LFG
VERTICAL TEE #6
EX. LFG
VERTICAL TEE #9
EW-N2-1
EW-N2-2
EW-N2-3
EW-N2-4
EW-N2-12
EW-N2-11
EW-N2-10
EW-N2-9
EW-N1-8
EW-N1-9
EW-N1-10
EW-N1-11
EW-N1-12
EW-N1-13
EW-N1-14
EW-N1-15
EW-N1-16
EW-N1-17
EW-N2-8
EW-N2-7
EW-N2-6
EW-N2-5
EW-N1-18
LF
G
LF
G
LF
G
LF
G
LFG
LFG
LFG
LFGL
LFGL
LFGL
LFG
L
LFG
L
LF
G
L
LF
G
L
LFGL
LF
G
L
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LF
GL
LF
GL
LF
GLLFG
L
LFG
L
LFG
L
LF
G
L
LF
G
L
LFG
L
LFG
L
LFGL
LFGL
LFGL
LFGL
LFGL
LFGL
LFGL
LF
G
L
LF
G L
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFGL
LFGL
LFGL
LFGL
LF
G
L
LFGL
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFGL
LFGL
LFG
LFG
LFG
LFG
EW-N1-1
EW-N1-2
EW-N1-3
EW-N1-4
EW-N1-5
EW-N1-6
EW-N1-7
LFGL
LFGL
LFGL
LFG
LF
G
LF
G
LF
G
LFG
LFG
LFG
LFG
LFG
LFG
LFG
LFGL
CD-9
440440
4" DIA. LFG LATERAL
PIPE (TYP.)
TIE-IN WITH EX. LFG
VERTICAL TEE #10
EX. 4" DIA. LFG
LATERAL PIPE (TYP.)
6" DIA. LFG
HEADER PIPE (TYP.)
4" DIA. LFG LATERAL
PIPE (TYP.)
TIE-IN WITH EX. LFG
VERTICAL TEE #11
4" DIA. LFG LATERAL
PIPE (TYP.)
BENCH CROSSING
SEE DETAIL
SHEET C-504
BENCH CROSSING
SEE DETAIL SHEET C-504
BENCH CROSSING
SEE DETAIL SHEET C-504
BENCH CROSSING
SEE DETAIL SHEET C-504
BENCH CROSSING
SEE DETAIL SHEET C-504
BENCH CROSSING
SEE DETAIL SHEET C-504
4" DIA. LFG LATERAL
PIPE (TYP.)
4" DIA. LFG LATERAL
PIPE (TYP.)
BENCH CROSSING
SEE DETAIL SHEET C-504
ISOLATION VALVE
(TYP.)
ISOLATION VALVE
(TYP.)
TIE-IN WITH EX. LFG
VERTICAL TEE #8
6" DIA. LFG HEADER
PIPE (TYP.)
TIE-IN WITH EX. LFG
VERTICAL TEE #12
TIE-IN WITH EX. LFG
VERTICAL TEE #13
BENCH CROSSING
SEE DETAIL SHEET C-504
TIE-IN WITH EX. LFG
VERTICAL TEE #1
TIE-IN WITH EX. LFG
VERTICAL TEE #2
TIE-IN WITH EX. LFG
VERTICAL TEE #3
BENCH CROSSING
SEE DETAIL SHEET C-504
BENCH CROSSING
SEE DETAIL SHEET C-504
TIE-IN WITH EX. LFG
VERTICAL TEE #14
TIE-IN WITH EX. LFG
VERTICAL TEE #5
TIE-IN WITH EX. LFG
VERTICAL TEE #6
ISOLATION VALVE
(TYP.)
ISOLATION VALVE
(TYP.)
TIE-IN WITH EX. LFG
VERTICAL TEE #9
BENCH CROSSING
SEE DETAIL SHEET C-504
GABION SWALE
(TYP.)
RIPRAP SWALES
GABION SWALE
(TYP.)
BENCH CROSSING
SEE DETAIL SHEET C-504
CELL N1
GRAPHIC SCALE IN FEET
0 25 50 100
FI
LE
P
AT
H : Q
:\P R
O
JE
C
TS
\1
H
W D
C L
FG
E
XP
AN
SI
O
N \C
AD
\P
R O
D U
C
TI
O N
\D
ES
IG
N
S
ET
\1
H
W D
C L
FG
E
XP
AN
SI
O
N
PL
AN
SE
T.
D W
G [C
-1
] S U
LT
AN
A, S
H
AR
M
IN
/3
0/
:5
PM
PROFESSIONAL CERTIFICATION. I HEREBY CERTIFY THAT
THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME,
AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF MARYLAND,
LICENSE NO. 36798
EXPIRATION DATE: 01-19-2027
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
R
EA Engineering, Science, and Technology, Inc., PBC www.eaest.com
OF 10
C-103
MD83F
NAVD88
3241 SCARBORO ROAD
STREET, MARYLAND 21154
HARFORD WASTE DISPOSAL
CENTER
LANDFILL GAS EXPANSION
DESIGN
DRAWN BY: DPA DESIGNED BY: SS
CHECKED BY: SMD/GAT PROJECT MANAGER: LJO
PROJECT NUMBER: 1577623
DATE: APRIL 2026 SHEET:
DRAWING NO.
DRAWING INFORMATION
DRAWING TITLE
PROJECT ADDRESS
PROJECT NAME
SEAL
REVISIONS
225 Schilling Circle, Suite 400 Hunt Valley, Maryland 21031
(410) 584-7000
FULL SIZE PLOT: 24" x 36"
HORIZONTAL DATUM:
VERTICAL DATUM:
PROPOSED LFG EXTRACTION
WELL LAYOUT
FINAL CONDITION
CELL N2
FOR INFORMATION ONLY - NOT IN CONTRACT
LE
P
AT
H : Q
:\P R
O
JE
C
TS
\1
H
W D
C L
FG
E
XP
AN
SI
O
N \C
AD
\P
R O
D U
C
TI
O N
\D
ES
IG
N
S
ET
\1
H
W D
C L
FG
E
XP
AN
SI
O
N
PL
AN
SE
T.
D W
G [C
-5
] S U
LT
AN
A, S
H
AR
M
IN
/3
0/
:5
PM
PROFESSIONAL CERTIFICATION. I HEREBY CERTIFY THAT
THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME,
AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF MARYLAND,
LICENSE NO. 36798
EXPIRATION DATE: 01-19-2027
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
R
EA Engineering, Science, and Technology, Inc., PBC www.eaest.com
OF 10
C-501
MD83F
NAVD88
3241 SCARBORO ROAD
STREET, MARYLAND 21154
HARFORD WASTE DISPOSAL
CENTER
LANDFILL GAS EXPANSION
DESIGN
DRAWN BY: DPA DESIGNED BY: SS
CHECKED BY: SMD/GAT PROJECT MANAGER: LJO
PROJECT NUMBER: 1577623
DATE: APRIL 2026 SHEET:
DRAWING NO.
DRAWING INFORMATION
DRAWING TITLE
PROJECT ADDRESS
PROJECT NAME
SEAL
REVISIONS
225 Schilling Circle, Suite 400 Hunt Valley, Maryland 21031
(410) 584-7000
FULL SIZE PLOT: 24" x 36"
HORIZONTAL DATUM:
VERTICAL DATUM:
LFG EXTRACTION WELL
DETAILS
INTERIM CONDITION
WASTE
800-624-2026 www.qedenv.com
SLOPE
800-624-2026 www.qedenv.com
ABOVEGROUND
PIPING TO HEADER
FROM EXTRACTION WELL
ELEVATION
TRADITIONAL LANDFILL GAS EXTRACTION WELL
(INTERIM CONDITION)
NOT TO SCALE
LANDFILL GAS WELLHEAD
(INTERIM CONDITION)
NOT TO SCALE
G
AS
FL
O
W
3' DIA.
1'
15'
DEPTH VARIES
REFER TO TABLE
4" 4' ±
3'
30"
2'
2'
FEMALE QUICK CONNECT
MANUFACTURED BY McMASTER-CARR
PART # 5012K31 OR APPROVED EQUAL
2" X 4" FLEXIBLE
COUPLING
4" DIA. PIPE
2" SCH. 80 PVC PIPE
GWC62 WELL CAP 6" WELL x
2" GAS WELLHEAD
2" ORIFICE PLATE ASSEMBLY
2" PRECISION CONTROL VALVE2" DIA. FLEXIBLE HOSE
2" SCH. 80 PVC PIPE
6" Ø PIPE
6" FLEXIBLE COUPLING
1/4" LABLOCK
LANDFILL GAS WELLHEAD
(SEE DETAIL THIS SHEET)
GRAVEL PAD
(SEE DETAIL THIS SHEET)
GENERAL FILL
2' BENTONITE PLUG
6" HDPE SDR17 PERFORATED PIPE
PERFORATIONS SHALL BE 1/2" DIA. HOLES
SPACED 90° APART AROUND PERIMETER
EVERY 6" FOR ENTIRE PERFORATED LENGTH.
GEOCOMPOSITE ISOLATION RING
LENGTH VARIES
(REFER TO TABLE)
GRANULAR FILL
HDPE END CAP
BOTTOM OF WELL
LANDFILL GAS HEADER ISOLATION VALVE
(INTERIM CONDITION)
NOT TO SCALE
GRAVEL PAD
(SEE DETAIL
THIS SHEET)
3'3'
EXISTING CONDITIONS
2' MIN.
UTILITY
MARKER (TYP)
GAS SAMPLE
PORT AND FEMALE
END TO ACCEPT
TEST PORT, TYP.
COVER
GRAVEL PAD
(SEE DETAIL
THIS SHEET)
TWO PIECE REMOVABLE STEM 1/4" S.S. TUBING, TYP.
FLOW
MIN.
DISTANCE TO
ALLOW FOR
BUTT FUSION
6" DIA. LFG
HEADER PIPE
HDPE VALVE STEM
AND SAMPLING TUBE
SLEEVE
TAP
6" BUTTERFLY VALVE
PROVIDE PIPE BEDDING
FOR SUPPORT
MIN. 12"
BUTT WELDED
FLANGE, TYP.
EX. CONDITIONS
INSTALLATION NOTES:
1. WELLHEAD CASING DRILLING DEPTH TO BE DETERMINED BASED ON LFG EXTRACTION WELL SCHEDULE, FIELD CONDITIONS AND THE ENGINEER'S DIRECTION.
2. WELLHEAD AND FLOW MEASUREMENT TUBE ASSEMBLY SHALL BE COMPATIBLE WITH CES-LANDTEC
GEM-500, GEM-2000, AND GEM-5000 (LANDFILL GAS INSTRUMENTS).
3. 2" WELLHEAD SHALL BE RATED FOR A FLOW RANGE OF 0-50 SCFM.
4. FOR FLEXIBLE CONNECTIONS TO PIPE USE ONLY STAINLESS STEEL V-BAND CLAMPS.
5. GECOMPOSITE ISOLATION RING SHALL FIT SNUG TO EXTRACTION WELL TO PROVIDE SEPARATION BETWEEN
STONE AND BENTONITE PLUG.
NOTES:
1. BURIED VALVES SHALL USE STAINLESS STEEL HARDWARE WITH ANTISEIZE COMPOUND AND BE
WRAPPED IN POLYETHYLENE SHEETING PRIOR TO BACKFILLING.
2. VALVES SHALL HAVE PERMANENT (NOT PAINTED) OPEN/CLOSE POSITION INDICATOR ON VALVE HANDLE
3. ALL VALVES SHALL BE CLEARLY MARKED WITH VALVE ID.
4. IF NOT BURIED, AN OPERATING WHEEL MAY BE PLACED IN LIEU OF STEM, AS APPROVED BY THE
ENGINEER.
INSTALLATION NOTES:
1. DRAWING SHOWS TYPICAL CONNECTION TO A 90° ELBOW.
ACTUAL CONNECTION MAY BE TO A TEE OR COUPLING.
2. WARNING: DO NOT CUT THE FLOW MEASUREMENT TUBE
ASSEMBLY. FAILURE TO HEED THIS WARNING WILL RESULT
IN A DAMAGED OR INOPERATIVE WELLHEAD AND VOID THE
WARRANTY.
3. ALLOW SUFFICIENT SLACK IN FLEX HOSE FOR PIPING
EXPANSION AND CONTRACTION. AN EXTRA 6-12" IS
RECOMMENDED.
4. SUPPLY BRASS ID TAG WITH NUMBER AT EACH WELLHEAD.
5. REFER TO QED WELLHEAD INSTALLATION AND OPERATION
MANUAL. READ INSTRUCTIONS THOROUGHLY BEFORE
ATTEMPTING ASSEMBLY AND INSTALLATION OF WELLHEAD
ON WELL CASING.
6. 4" DIA. PIPE TO TERMINATE ABOVE GRADE IF LATERAL
PIPING IS NOT BURIED.
EX. CONDITIONS
2'
3' MIN.
EX. 8" FUSION WELDED CAP
EX. CONDITIONS
EX. 12" x 8" HDPE
REDUCING TEE
EX. 8" DR 17 HDPE
GAS HEADER VERTICAL TEE
(INTERIM/FINAL CONDITION)
NOT TO SCALE
NOTES:
1. PROVIDE A MINIMUM OF 1 FT OF COVER OVER PROPOSED LANDFILL GAS HEADER PIPE.
2. INVERT ELEVATION FOR EX. LFG HEADER BASED ON MALCOLM PIRNIE DESIGN
DRAWINGS (MALCOLM PIRNIE 2011).
APPROX. LOCATION
OF EX. LINER TRENCH
PROP. 6" DIA. LFG HEADER PIPE
OR 4" DIA. LFG LATERAL PIPE
APPROX. 5'
EX. 12" DIA. LFG
HEADER PIPE
PROP. 8" x 6" HDPE TEE OR 8" x 4" HDPE TEE
HEADER PIPE TO
COLLECTION
PIPING
FEMALE QUICK CONNECTS
MANUFACTURED BY
McMASTER-CARR
PART # 5012K31 OR
APPROVED EQUAL
PIPING TRENCH DETAIL
(INTERIM CONDITION)
NOT TO SCALE
D
D/2D/2
6"
6"
2' MIN.
DETECTOR TAPE
4" OR 6" DIA. SDR 17 HDPE
LFG COLLECTION
EX. CONDITIONS
SOIL BEDDING
NOTE:
1. THE LFG COLLECTION PIPE MAY BE PLACED ABOVE GRADE WITH VISIBLE MARKINGS.
GENERAL BACKFILL
6"
3'
(TYP.)
EMBED 6" MIN. (TYP.)
EXISTING 12-IN LFG HEADER VERTICAL TEE SCHEDULE
TEE ID NORTHING EASTING
TOP OF CAP
ELEVATION
(FT)
INVERT
ELEVATION
(FT)
1 720072.64 1510379.77 418.85 412.74
2 720193.28 1510468.36 420.14 414.27
3 720316.18 1510558.38 421.09 415.78
4 720306.41 1510753.75 421.15 415.38
5 720240.50 1511038.25 403.46 399.74
6 720325.91 1511307.08 379.92 375.92
7 720129.94 1511503.88 353.74 349.94
8 719884.61 1511680.57 336.51 332.78
9 719528.66 1511743.55 302.86 299.10
10 719438.56 1511625.64 300.82 296.14
11 719388.78 1511104.34 300.78 296.75
12 719373.88 1510846.09 328.52 324.13
13 719562.06 1510622.09 366.32 361.38
14 719766.87 1510398.75 405.38 399.49
15 719941.15 1510317.13 410.62 410.62
NOTE:
1. EXISTING VERTICAL TEE LOCATIONS AND TOP OF CAP ELEVATIONS BASED ON MES
SURVEY PERFORMED JUNE 2024.
2. INVERT ELEVATIONS WERE BASED ON CONSTRUCTION OF CELL N1 RECORD
DRAWINGS PREPARED BY MALCOM PIRNIE IN DECEMBER 2009.
INTERIM CONDITION TRADITIONAL LANDFILL GAS EXTRACTION WELL SCHEDULE
WELL ID
PROPOSED LOCATION EXISTING
ELEVATION
(FT)
APPROX.
LINER
ELEVATION
(FT)
APPROX. WELL
DEPTH (FT)
FROM
EXISTING
ELEVATION
APPROX.
PERFORATED
PIPE LENGTH
(FT)
APPROX.
WELL BOTTOM
ELEVATION
(FT)NORTHING EASTING
EW-N1-8 720059.82 1510530.10 447.6 391.27 46 31 401.6
EW-N1-9 719911.44 1510684.12 444.2 370.21 64 49 380.2
EW-N1-11 719906.97 1510447.80 436.9 389.06 38 23 398.9
EW-N1-12 719746.01 1510612.23 413.2 366.32 36 21 377.2
EW-N1-13 719743.35 1510813.96 419.6 349.60 58 43 361.6
EW-N1-14 719606.27 1510780.34 387.1 344.81 32 17 355.1
EW-N1-15 719702.13 1511036.02 375.5 330.02 35 20 340.5
EW-N1-16 719514.83 1510886.35 357.1 323.95 23 8 334.1
EW-N1-17 719521.74 1511213.22 328.9 299.66 19 4 309.9
EW-N1-18 719535.52 1511055.66 347.8 308.95 28 13 319.8
EW-N2-4 719654.26 1511665.05 337.0 297.86 29 14 308.0
EW-N2-5 719545.70 1511553.31 325.4 292.45 22 7 303.4
NOTE:
1. CONTRACTOR TO SURVEY AND CONFIRM EXISTING CONDITIONS ELEVATIONS AND PROVIDE SURVEY RESULTS FOR
ENGINEER REVIEW AND APPROVAL, PRIOR TO LFG EXTRACTION WELL INSTALLATION.
2. EXISTING ELEVATIONS AT THESE LOCATIONS WERE PROVIDED BY MES VIA EMAIL ON 30 MARCH 2026.
SECTION VIEW
PLAN VIEW
NOTES:
1. GRAVEL PAD TO BE CENTERED ON SINGLE
PENETRATIONS.
2. 72" MARKER POST SHALL HAVE WELL ID. PLACE
TWO MARKERS AT EACH WELL AT OPPOSITE
CORNERS.
2. ALL 72" MARKERS SHALL BE EMBEDDED A
MINIMUM OF 6" BELOW GRADE
GRAVEL PAD
(INTERIM CONDITION)
NOT TO SCALE
6'
6'
4"
72" FIBERGLASS UTILITY
MARKER WITH WELL ID
72" FIBERGLASS UTILITY
MARKER WITH WELL ID
PIPE TO HEADER
(IF BURIED)
WELLHEAD
8 OZ. GEOTEXTILE
3' 1'-6"1'-6"
NOT IN CONTRACT
NOT IN CONTRACT
NOT IN CONTRACT
LE
P
AT
H : Q
:\P R
O
JE
C
TS
\1
H
W D
C L
FG
E
XP
AN
SI
O
N \C
AD
\P
R O
D U
C
TI
O N
\D
ES
IG
N
S
ET
\1
H
W D
C L
FG
E
XP
AN
SI
O
N
PL
AN
SE
T.
D W
G [C
-5
] S U
LT
AN
A, S
H
AR
M
IN
/3
0/
:5
PM
PROFESSIONAL CERTIFICATION. I HEREBY CERTIFY THAT
THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME,
AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF MARYLAND,
LICENSE NO. 36798
EXPIRATION DATE: 01-19-2027
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
R
EA Engineering, Science, and Technology, Inc., PBC www.eaest.com
OF 10
C-502
MD83F
NAVD88
3241 SCARBORO ROAD
STREET, MARYLAND 21154
HARFORD WASTE DISPOSAL
CENTER
LANDFILL GAS EXPANSION
DESIGN
DRAWN BY: DPA DESIGNED BY: SS
CHECKED BY: SMD/GAT PROJECT MANAGER: LJO
PROJECT NUMBER: 1577623
DATE: APRIL 2026 SHEET:
DRAWING NO.
DRAWING INFORMATION
DRAWING TITLE
PROJECT ADDRESS
PROJECT NAME
SEAL
REVISIONS
225 Schilling Circle, Suite 400 Hunt Valley, Maryland 21031
(410) 584-7000
FULL SIZE PLOT: 24" x 36"
HORIZONTAL DATUM:
VERTICAL DATUM:
SCALE AS SHOWN
LFG EXTRACTION WELL
DETAILS
INTERIM CONDITION
2' MIN.
6"
3' 10"
12"
12"
GRANULAR FILL
4" DIA. HDPE
4"x8" DIA. HDPE ADAPTER BUSHING
8" DIA. HDPE SLIP COUPLING
DRILL 2 ROWS OF 4 HOLES;
1/2" DIA. EVENLY SPACED
AROUND PERIMETER OF PIPE
STAGGER THE ROWS
8" DIA. HDPE PIPE
8" DIA. HDPE PIPE CAP
EX.
WASTE
TYPICAL BLIND FLANGE
CONDENSATE DRAIN
(INTERIM CONDITION)
NOT TO SCALE
6" DIA. HDPE
LANDFILL
COLLECTION
HEADER
GENERAL BACKFILL
INTERIM CONDITION CELL N1 CONDENSATE DRAIN SCHEDULE
DRAIN ID NORTHING EASTING
EXISTING
ELEVATION (FT)
APPROX.
LINER
ELEVATION
(FT)
CONDENSATE
DRAIN BOTTOM
ELEVATION (FT)
CD-N1-1 719863.61 1510584.35 437.88 374.94 417.88
CD-N1-2 719924.51 1510863.70 400.70 362.00 380.70
CD-N1-3 719740.43 1511024.16 374.40 337.64 354.40
CD-N1-4 719697.34 1511055.99 372.10 327.14 352.10
CD-N1-5 719528.70 1511212.00 331.50 300.96 313.00
CD-N1-6 719888.99 1510433.49 432.20 389.36 412.20
4" DIA. HDPE PIPE
(3% TO MIN. SLOPE)
EX. CONDITIONS
GRAVEL PAD
(SEE DETAIL
SHEET C-501)
12" BENTONITE PLUG 3' MIN.
NOTES:
1. EXISTING ELEVATIONS AT THESE LOCATIONS WERE PROVIDED BY MES VIA EMAIL ON 30
MARCH 2026.
2. CONTRACTOR SHALL FILL 8" HDPE PIPE WITH WATER.
3. 4" HDPE PIPE TO EXTEND ABOVE GRADE IF HEADER PIPE IS NOT BURIED.
INTERIM CONDITION CAISSON TYPE LANDFILL GAS EXTRACTION WELL SCHEDULE
WELL ID
PROPOSED LOCATION EXISTING
ELEVATION
(FT)
APPROX.
LINER
ELEVATION
(FT)
APPROX. WELL
DEPTH (FT)
FROM
EXISTING
ELEVATION
APPROX.
PERFORATED
6" PIPE
LENGTH (FT)
APPROX.
WELL
BOTTOM
ELEVATION
(FT)
NORTHING EASTING
EW-N1-10 719906.31 1510891.83 395.9 359.01 27 24 369.0
EW-N2-3 719838.03 1511536.53 350.5 320.23 20 17 330.0
EW-N2-6 719758.95 1511445.76 358.5 319.11 25 22 333.5
EW-N2-11 719756.30 1511246.57 365.2 328.79 31 28 339.0
NOTE:
1. CONTRACTOR TO SURVEY AND CONFIRM EXISTING CONDITIONS ELEVATIONS AND PROVIDE SURVEY RESULTS FOR
ENGINEER REVIEW AND APPROVAL, PRIOR TO LFG EXTRACTION WELL INSTALLATION.
2. EXISTING ELEVATIONS AT THESE LOCATIONS WERE PROVIDED BY MES VIA EMAIL ON 30 MARCH 2026.
WASTE
LANDFILL GAS CAISSON TYPE EXTRACTION WELL
(INTERIM CONDITION)
NOT TO SCALE
3' DIA.
1'
20'
DEPTH VARIES
REFER TO TABLE
6" DIA. SCH. 40 PVC PERFORATED PIPE
PERFORATIONS SHALL BE 1/2" DIA. HOLES
SPACED 90° APART AROUND PERIMETER
EVERY 6" FOR ENTIRE PERFORATED LENGTH.
LENGTH VARIES
(REFER TO TABLE)
GRANULAR FILL
PVC END CAP
BOTTOM OF WELL
EX. CONDITIONS
2' MIN.
INSTALLATION NOTES:
1. WELLHEAD CASING DRILLING DEPTH TO BE DETERMINED BASED ON LFG EXTRACTION WELL SCHEDULE, FIELD
CONDITIONS AND THE ENGINEER'S DIRECTION.
2. WELLHEAD AND FLOW MEASUREMENT TUBE ASSEMBLY SHALL BE COMPATIBLE WITH CES-LANDTEC GEM-500, GEM-2000, AND GEM-5000 (LANDFILL GAS INSTRUMENTS).
3. 2" WELLHEAD SHALL BE RATED FOR A FLOW RANGE OF 0-50 SCFM.
4. FOR FLEXIBLE CONNECTIONS TO PIPE USE ONLY STAINLESS STEEL V-BAND CLAMPS.
5. GECOMPOSITE ISOLATION RING SHALL FIT TIGHT TO EXTRACTION WELL TO PROVIDE SEPARATION BETWEEN STONE
AND BENTONITE PLUG.
6. TRANSITION FITTING SHALL BE A 24" x 8" HDPE BUSHING WITH A 6" NIPPLE OF 8" SDR-17 HDPE WELDED TO THE TOP.
SOIL AND
BENTONITE
WASTE
30" DIA. BOLTED FLANGE
CONNECTION WITH GASKET
24" DIA. HDPE SDR-17
CAISSON PIPE
3' DIA.
GRAVEL PAD
(SEE DETAIL SHEET C-501)
FROM EXTRACTION WELL
LANDFILL GAS WELLHEAD FOR CAISSON TYPE EXTRACTION WELL
(INTERIM CONDITION)
NOT TO SCALE
G
AS
FL
O
W
INSTALLATION NOTES:
1. DRAWING SHOWS TYPICAL CONNECTION TO A 90° ELBOW. ACTUAL CONNECTION MAY
BE TO A TEE OR COUPLING.
2. WARNING: DO NOT CUT THE FLOW MEASUREMENT TUBE ASSEMBLY. FAILURE TO HEED
THIS WARNING WILL RESULT IN A DAMAGED OR INOPERATIVE WELLHEAD AND VOID
THE WARRANTY.
3. ALLOW SUFFICIENT SLACK IN FLEX HOSE FOR PIPING EXPANSION AND CONTRACTION.
AN EXTRA 6-12" IS RECOMMENDED.
4. SUPPLY BRASS ID TAG WITH NUMBER AT EACH WELLHEAD.
5. REFER TO QED WELLHEAD INSTALLATION AND OPERATION MANUAL. READ
INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING ASSEMBLY AND INSTALLATION OF
WELLHEAD ON WELL CASING.
6. 4" DIA. PIPE TO TERMINATE ABOVE GRADE IF LATERAL PIPING IS NOT BURIED.
12"
1' MIN.
6" DIA. SCH. 40 PVC SOLID PIPE
5'
LANDFILLGAS
WELLHEAD
ASSEMBLY
(SEE DETAIL
SHEET C-501) TRANSITION FITTING (SEE NOTE 6.)
6" FLEXIBLE COUPLING
GWC62 WELL CAP 6" WELL x
2" GAS WELLHEAD
2" ORIFICE PLATE ASSEMBLY
FEMALE QUICK CONNECT
MANUFACTURED BY McMASTER-CARR
PART # 5012K31 OR APPROVED EQUAL
2" PRECISION CONTROL VALVE
2" SCH. 80 PVC PIPE
1/4" LABLOCK
SLOPE
ABOVEGROUND
PIPING TO HEADER
2" X 4" FLEXIBLE
COUPLING
4" DIA. PIPE
6"
8"
FEMALE QUICK CONNECTS MANUFACTURED BY
McMASTER-CARR PART # 5012K31 OR APPROVED EQUAL
INTERMEDIATE
SOIL COVER 1'
8" x 6" FLEXIBLE
COUPLING
3'
WASTE
FI
LE
P
AT
H : Q
:\P R
O
JE
C
TS
\1
H
W D
C L
FG
E
XP
AN
SI
O
N \C
AD
\P
R O
D U
C
TI
O N
\D
ES
IG
N
S
ET
\1
H
W D
C L
FG
E
XP
AN
SI
O
N
PL
AN
SE
T.
D W
G [C
-5
] S U
LT
AN
A, S
H
AR
M
IN
/3
0/
:5
PM
PROFESSIONAL CERTIFICATION. I HEREBY CERTIFY THAT
THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME,
AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF MARYLAND,
LICENSE NO. 36798
EXPIRATION DATE: 01-19-2027
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
R
EA Engineering, Science, and Technology, Inc., PBC www.eaest.com
OF 10
C-503
MD83F
NAVD88
3241 SCARBORO ROAD
STREET, MARYLAND 21154
HARFORD WASTE DISPOSAL
CENTER
LANDFILL GAS EXPANSION
DESIGN
DRAWN BY: DPA DESIGNED BY: SS
CHECKED BY: SMD/GAT PROJECT MANAGER: LJO
PROJECT NUMBER: 1577623
DATE: APRIL 2026 SHEET:
DRAWING NO.
DRAWING INFORMATION
DRAWING TITLE
PROJECT ADDRESS
PROJECT NAME
SEAL
REVISIONS
225 Schilling Circle, Suite 400 Hunt Valley, Maryland 21031
(410) 584-7000
FULL SIZE PLOT: 24" x 36"
HORIZONTAL DATUM:
VERTICAL DATUM:
FINAL CONDITION TRADITIONAL LANDFILL GAS EXTRACTION WELL SCHEDULE
WELL ID
PROPOSED LOCATION N1-N2 CLOSURE
CAP ELEVATION
(FT)
APPROX.
LINER
ELEVATION
(FT)
APPROX. EXISITING
WELL EXTENSION
(FT) TO CLOSURE
CAP
APPROX. TOTAL
WELL DEPTH
FROM CLOSURE
CAP (FT)NORTHING EASTING
EW-N1-1 720206.88 1510652.99 458.35 394.13 5 54
EW-N1-2 720152.84 1510730.68 455.22 386.54 12 59
EW-N1-3 720090.87 1510796.05 460.37 379.07 43 71
EW-N1-4 720135.18 1510599.33 459.41 391.46 6 58
EW-N1-5 720111.56 1510662.81 473.02 385.76 19 77
EW-N1-6 720059.68 1510728.93 473.40 379.45 40 84
EW-N1-7 720008.42 1510802.00 472.81 372.11 57 91
EW-N1-8 720059.82 1510530.10 453.90 391.27 7 53
EW-N1-9 719923.09 1510663.08 471.98 372.25 23 89
EW-N1-11 719906.97 1510447.80 445.81 389.06 8 47
EW-N1-12 719746.01 1510612.23 417.61 366.32 9 41
EW-N1-13 719743.35 1510813.96 431.12 349.60 13 72
EW-N1-14 719606.27 1510780.34 391.44 344.81 8 37
EW-N1-15 719702.13 1511036.02 396.38 330.02 24 56
EW-N1-16 719514.83 1510886.35 359.50 323.95 2 26
EW-N1-17 719521.74 1511213.22 330.56 299.66 -6 (SHORTEN) 21
EW-N1-18 719535.52 1511055.66 349.41 308.95 4 30
EW-N2-4 719654.26 1511665.05 345.43 297.99 8 37
EW-N2-5 719545.70 1511553.31 330.36 292.22 5 28
EW-N2-12 719565.31 1511429.18 341.58 307.22 4 24 LFG EXTRACTION WELL
DETAILS
FINAL CONDITION
WASTE
800-624-2026 www.qedenv.com
TRADITIONAL LANDFILL GAS EXTRACTION WELL
(FINAL CONDITION)
NOT TO SCALE
LANDFILL GAS WELLHEAD
(SEE DETAIL SHEET C-504)
GRAVEL PAD
(SEE DETAIL SHEET C-504)
EXISTING 2' BENTONITE PLUG
EXISTING 6" HDPE SDR17 PERFORATED PIPE
EXISTING GEOCOMPOSITE ISOLATION RING
GRANULAR FILL
HDPE END CAP
BOTTOM OF WELL
LANDFILL GAS HEADER ISOLATION VALVE
(FINAL CONDITION)
NOT TO SCALE
UTILITY
MARKER (TYP)
GAS SAMPLE
PORT AND FEMALE
END TO ACCEPT
TEST PORT, TYP.
COVER
GRAVEL PAD
(SEE DETAIL
SHEET C-504)
TWO PIECE REMOVABLE STEM 1/4" S.S. TUBING, TYP.
FLOW
MIN.
DISTANCE TO
ALLOW FOR
BUTT FUSION
6" DIA. LFG
HEADER PIPE
HDPE VALVE STEM
AND SAMPLING TUBE
SLEEVE
TAP
6" BUTTERFLY VALVE
PROVIDE PIPE BEDDING
FOR SUPPORTBUTT WELDED
FLANGE, TYP.
FINAL CONDITIONS
INSTALLATION NOTES:
1. WELLHEAD CASING DRILLING DEPTH TO BE DETERMINED BASED ON LFG EXTRACTION WELL SCHEDULE, FIELD CONDITIONS AND THE ENGINEER'S DIRECTION.
2. WELLHEAD AND FLOW MEASUREMENT TUBE ASSEMBLY SHALL BE COMPATIBLE WITH CES-LANDTEC
GEM-500, GEM-2000, AND GEM-5000 (LANDFILL GAS INSTRUMENTS).
3. 2" WELLHEAD SHALL BE RATED FOR A FLOW RANGE OF 0-50 SCFM.
4. FOR FLEXIBLE CONNECTIONS TO PIPE USE ONLY STAINLESS STEEL V-BAND CLAMPS.
5. GECOMPOSITE ISOLATION RING SHALL FIT TIGHT TO EXTRACTION WELL TO PROVIDE SEPARATION BETWEEN
STONE AND BENTONITE PLUG.
NOTES:
1. BURIED VALVES SHALL USE STAINLESS STEEL HARDWARE WITH
ANTISEIZE COMPOUND AND BE WRAPPED IN POLYETHYLENE SHEETING
PRIOR TO BACKFILLING.
2. VALVES SHALL HAVE PERMANENT (NOT PAINTED) OPEN/CLOSE
POSITION INDICATOR ON VALVE HANDLE
3. ALL VALVES SHALL BE CLEARLY MARKED WITH VALVE ID.
4. IF NOT BURIED, AN OPERATING WHEEL MAY BE PLACED IN LIEU OF
STEM, AS APPROVED BY THE ENGINEER.
LANDFILL GAS CAISSON TYPE EXTRACTION WELL
(FINAL CONDITION)
NOT TO SCALE
INSTALLATION NOTES:
1. WELLHEAD CASING DRILLING DEPTH TO BE DETERMINED BASED ON LFG EXTRACTION WELL SCHEDULE, FIELD CONDITIONS AND THE ENGINEER'S DIRECTION.
2. WELLHEAD AND FLOW MEASUREMENT TUBE ASSEMBLY SHALL BE COMPATIBLE WITH CES-LANDTEC
GEM-500, GEM-2000, AND GEM-5000 (LANDFILL GAS INSTRUMENTS).
3. 2" WELLHEAD SHALL BE RATED FOR A FLOW RANGE OF 0-50 SCFM.
4. FOR FLEXIBLE CONNECTIONS TO PIPE USE ONLY STAINLESS STEEL V-BAND CLAMPS.
5. GECOMPOSITE ISOLATION RING SHALL FIT SNUG TO EXTRACTION WELL TO PROVIDE SEPARATION BETWEEN
STONE AND BENTONITE PLUG.
WASTE
LANDFILL GAS WELLHEAD
(SEE DETAIL SHEET C-504)
6" DIA. SCH. 40 PVC PERFORATED PIPE
PERFORATIONS SHALL BE 1/2" DIA. HOLES
SPACED 90° APART AROUND PERIMETER
EVERY 6" FOR ENTIRE PERFORATED LENGTH.
GRANULAR FILL
PVC END CAP
BOTTOM OF WELL
FINAL CONDITIONS
OPEN END
OF CAISSON
800-624-2026 www.qedenv.com
24" DIA. CAISSON
EX. 30" FLANGED CAISSON CONNECTION
VEGETATIVE
SUPPORT SOIL
CLOSURE CAP
SUBGRADE
GEOCOMPOSITE
GEOMEMBRANE
GEOTEXTILE
VEGETATIVE
SUPPORT SOIL
CLOSURE CAP
SUBGRADE
GEOCOMPOSITE
GEOMEMBRANE
GEOTEXTILE
4" TOPSOIL
4" TOPSOIL
4" TOPSOIL
VEGETATIVE
SUPPORT SOIL
NOTE:
1. CONTRACTOR TO SURVEY AND CONFIRM EXISTING CONDITIONS ELEVATIONS AND PROVIDE SURVEY RESULTS FOR ENGINEER
REVIEW AND APPROVAL, PRIOR TO LFG EXTRACTION WELL INSTALLATION.
FINAL CONDITIONS
EXISTING 6" HDPE LANDFILL
GAS EXTRACTION WELL
3' DIA.
1'
15'
DEPTH VARIES
REFER TO TABLE
4"
LENGTH VARIES
(REFER TO TABLE)
3'3'2' MIN.
MIN. 12"
3'-0" DIA.
1'-0"
WASTE
DEPTH
VARIES
DEPTH VARIES
REFER TO TABLE
LENGTH VARIES
(REFER TO TABLE)
2' MIN.
2'-0" DIA.
CAISSON
2' MIN.
2' MIN.
PIPING TRENCH DETAIL (WITHIN LANDFILL)
(FINAL CONDITION)
NOT TO SCALE
DETECTOR TAPE
4" OR 6" DIA. SDR 17 HDPE
LFG COLLECTION
EX. CLOSURE CAP SUBGRADE
APPROX. 2' DEEP WITH WASTE BELOW
SOIL BEDDING
D D/2D/2
6"
6"
2' MIN.
3'
(TYP.)
VEGETATIVE
SUPPORT SOIL
GEOCOMPOSITE
GEOMEMBRANE
GEOTEXTILE
4" TOPSOIL
PIPING TRENCH DETAIL (OUTSIDE LANDFILL)
(FINAL CONDITION)
NOT TO SCALE
DETECTOR TAPE
4" OR 6" DIA. SDR 17 HDPE
LFG COLLECTION
EX. CONDITIONS
SOIL BEDDING
D
D/2D/2
6"
6"
2' MIN.
GENERAL BACKFILL
6"
6"
EMBED 12" MAX. (TYP.)
10' MIN.
6" HDPE
SDR17
SOLID PIPE
FINAL CONDITION CAISSON LANDFILL GAS EXTRACTION WELL SCHEDULE
WELL ID
PROPOSED LOCATION N1-N2 CLOSURE
CAP ELEVATION
(FT)
APPROX. LINER
ELEVATION (FT)
APPROX. EXISITING
WELL EXTENSION
(FT) TO CLOSURE
CAP
APPROX. TOTAL
WELL DEPTH FROM
CLOSURE CAP (FT)NORTHING EASTING
EW-N1-10 719906.31 1510891.83 468.41 359.01 72 99
EW-N2-1 720213.77 1511301.77 400.84 361.40 32 29
EW-N2-2 720027.15 1511409.40 388.71 339.83 38 39
EW-N2-3 719838.03 1511536.53 380.01 320.19 29 50
EW-N2-6 719758.95 1511445.76 399.26 319.03 41 70
EW-N2-7 719979.49 1511308.88 422.23 341.39 70 71
EW-N2-8 720152.22 1511164.23 434.17 365.34 65 59
EW-N2-9 720077.33 1511022.62 444.00 371.63 71 62
EW-N2-10 719922.11 1511127.55 450.69 348.22 93 92
EW-N2-11 719756.30 1511246.57 400.58 328.3 33 62
NOTE:
1. CONTRACTOR TO SURVEY AND CONFIRM EXISTING CONDITIONS ELEVATIONS AND PROVIDE SURVEY RESULTS FOR ENGINEER REVIEW
AND APPROVAL, PRIOR TO LFG EXTRACTION WELL INSTALLATION.
DEPTH VARIES
15'
SOIL BACKFILL
2' BENTONITE PLUG
6" HDPE SDR17 PERFORATED PIPE
PERFORATIONS SHALL BE 1/2" DIA. HOLES
SPACED 90° APART AROUND PERIMETER
EVERY 6" FOR ENTIRE PERFORATED LENGTH.
GEOCOMPOSITE ISOLATION RING
6" HDPE LANDFILL GAS
EXTRACTION WELL
EXISTING SOIL BACKFILL
CUT EXISTING HDPE PIPE AND INSTALL
FLANGE CONNECTION
(SEE DETAIL C-504)
PERFORATED
LENGTH VARIES
(REFER TO TABLE)
SOIL BACKFILL
2' BENTONITE PLUG
EXISTIN
G
PR
O
PO
SED
EX
IS
TI
N
G
PR
O
PO
SE
D
LLDPE LINER PENETRATION
(SEE DETAIL SHEET C-504)
LLDPE LINER PENETRATION
(SEE DETAIL SHEET C-504)
GRAVEL PAD
(SEE DETAIL SHEET C-504)
GEOCOMPOSITE ISOLATION RING
FOR INFORMATION ONLY - NOT IN CONTRACT
6" DIA. SCH. 40 PVC SOLID PIPE
LE
P
AT
H : Q
:\P R
O
JE
C
TS
\1
H
W D
C L
FG
E
XP
AN
SI
O
N \C
AD
\P
R O
D U
C
TI
O N
\D
ES
IG
N
S
ET
\1
H
W D
C L
FG
E
XP
AN
SI
O
N
PL
AN
SE
T.
D W
G [C
-5
] S U
LT
AN
A, S
H
AR
M
IN
/3
0/
:5
PM
PROFESSIONAL CERTIFICATION. I HEREBY CERTIFY THAT
THESE DOCUMENTS WERE PREPARED OR APPROVED BY ME,
AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF MARYLAND,
LICENSE NO. 36798
EXPIRATION DATE: 01-19-2027
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
R
EA Engineering, Science, and Technology, Inc., PBC www.eaest.com
OF 10
C-504
MD83F
NAVD88
3241 SCARBORO ROAD
STREET, MARYLAND 21154
HARFORD WASTE DISPOSAL
CENTER
LANDFILL GAS EXPANSION
DESIGN
DRAWN BY: DPA DESIGNED BY: SS
CHECKED BY: SMD/GAT PROJECT MANAGER: LJO
PROJECT NUMBER: 1577623
DATE: APRIL 2026 SHEET:
DRAWING NO.
DRAWING INFORMATION
DRAWING TITLE
PROJECT ADDRESS
PROJECT NAME
SEAL
REVISIONS
225 Schilling Circle, Suite 400 Hunt Valley, Maryland 21031
(410) 584-7000
FULL SIZE PLOT: 24" x 36"
HORIZONTAL DATUM:
VERTICAL DATUM:
LFG EXTRACTION WELL
DETAILS
FINAL CONDITION
DUCTILE IRON WITH RED OXIDE PRIMER
BACK-UP RING W/SS NUTS AND BOLTS
HDPE PIPE
(SIZE VARIES)
HDPE STUB END
(SIZE VARIES)
PIPE COUPLING
(SIZE VARIES)
HDPE PIPE
(SIZE VARIES)
GASKET
(SIZE VARIES)
NOTES:
1. CONNECTION DETAIL IS A COMPRESSION FITTING, WHICH IS
TYPICAL OF ALL GAS PIPELINE CONNECTIONS WHERE INDICATED.
2. GASKETS SHALL BE VITON OR APPROVED EQUAL.
3. PROVIDE PIPE COUPLING AS REQUIRED.
HDPE FLANGE
(SIZE VARIES)
HDPE FLANGE
(SIZE VARIES)
GAS COLLECTION PIPING FLANGE CONNECTION DETAIL
NOT TO SCALE
WASTE
CLOSURE CAP SUBGRADE
VEGETATIVE
SUPPORT SOIL
6' x 6' x 4" GRAVEL PAD
(SEE DETAIL THIS SHEET)
HDPE CLOSURE LINER PENETRATION
(SEE DETAIL THIS SHEET)
BENCHING
LANDFILL GAS LATERAL
(3% MIN. SLOPE, SEE NOTE 1)
LANDFILL GAS WELLHEAD
LANDFILL GAS EXTRACTION WELL
1'±
NOTES:
1. CONTRACTOR SHALL ADJUST BURIAL DEPTH ACROSS BENCHES TO MAINTAIN 3.0% MINIMUM SLOPE
WITHIN LANDFILL GAS COLLECTION SYSTEM.
2. THIS DETAIL APPLIES WHERE LANDFILL GAS LATERAL PIPING CROSSES A BENCH OR WHERE AN
EXTRACTION WELL IS LOCATED ON A BENCH.
4" MIN.
4" TOPSOIL
LANDFILL GAS LATERAL BENCH CROSSING
(FINAL CONDITION)
NOT TO SCALE
GEOCOMPOSITE
GEOMEMBRANE
GEOTEXTILE
2' MIN.
SLOPE
800-624-2026 www.qedenv.com
COLLECTION LATERAL
PIPING TO HEADER
FROM EXTRACTION WELL
ELEVATION
LANDFILL GAS WELLHEAD
(FINAL CONDITION)
NOT TO SCALE
G
AS
FL
O
W
4' ±
2'
30"
2'-0"
2'
FEMALE QUICK CONNECT
MANUFACTURED BY McMASTER-CARR
PART # 5012K31 OR APPROVED EQUAL
2" X 4" FLEXIBLE
COUPLING
4" DIA. PIPE
2" SCH. 80 PVC PIPE
GWC62 WELL CAP 6" WELL x
2" GAS WELLHEAD
2" ORIFICE PLATE ASSEMBLY
2" PRECISION CONTROL VALVE2" DIA. FLEXIBLE HOSE
2" SCH. 80 PVC PIPE
6" PIPE
6" FLEXIBLE COUPLING
1/4" LABLOCK
GRAVEL PAD
(SEE DETAIL THIS SHEET)
INSTALLATION NOTES:
1. DRAWING SHOWS TYPICAL CONNECTION TO A 90° ELBOW. ACTUAL CONNECTION MAY BE TO A TEE OR
COUPLING.
2. WARNING: DO NOT CUT THE FLOW MEASUREMENT TUBE ASSEMBLY. FAILURE TO HEED THIS WARNING WILL
RESULT IN A DAMAGED OR INOPERATIVE WELLHEAD AND VOID THE WARRANTY.
3. ALLOW SUFFICIENT SLACK IN FLEX HOSE FOR PIPING EXPANSION AND CONTRACTION. AN EXTRA 6-12" IS
RECOMMENDED.
4. SUPPLY BRASS ID TAG WITH NUMBER AT EACH WELLHEAD.
5. REFER TO QED WELLHEAD INSTALLATION AND OPERATION MANUAL. READ INSTRUCTIONS THOROUGHLY
BEFORE ATTEMPTING ASSEMBLY AND INSTALLATION OF WELLHEAD ON WELL CASING.
6. 4" DIA. PIPE TO TERMINATE ABOVE GRADE IF LATERAL PIPING IS NOT BURIED.
FINAL
CONDITIONS
FEMALE QUICK CONNECTS
MANUFACTURED BY
McMASTER-CARR
PART # 5012K31 OR
APPROVED EQUAL
VEGETATIVE
SUPPORT SOIL
CLOSURE CAP
SUBGRADE
GEOCOMPOSITE
GEOMEMBRANE
GEOTEXTILE
4" TOPSOIL
WASTE
CL CL
CL
TRADITIONAL LANDFILL GAS WELL EXTENSION
(FINAL CONDITION)
NOT TO SCALE
CLOSURE CAP SUBGRADE 2'
EXISTING WELL HEAD
NOTES:
1. BACKFILL WITHIN 5-FT OF LANDFILL GAS EXTRACTION WELL TO BE PERFORMED BY HAND.
2. PLACE BACKFILL SOIL BY HAND IN MAXIMUM 8-IN LIFTS AND MECHANICALLY TAMP.
3. CONTINUE TO PLACE BACKFILL IN LIFTS AND COMPACT UNTIL FINAL SUBGRADE
ELEVATION IS ACHIEVED.
4. VEGETATIVE SUPPORT SOIL AND TOPSOIL NOT SHOWN FOR CLARITY.
EXISTING BACKFILL APPRX. 36"ØEXISTING 6" HDPE LANDFILL
GAS EXTRACTION WELL
EXTEND EXISTING LANDFILL GAS WELL WITH 6" HDPE SDR17
PIPE PER LFG EXTRATION WELL DETAIL,
THIS SHEET AND INSTALL LANDFILL GAS WELLHEAD
PER THE LANDFILL GAS WELLHEAD DETAIL, SHEET C-501
GEOSYNTHETIC CLOSURE CAPPROPOSED GRADE
(VARIES)
CUT EXISTING HDPE PIPE AND INSTALL FLANGE CONNECTION PER
THE GAS COLLECTION PIPING FLANGE CONNECTION DETAIL
(SEE DETAIL THIS SHEET)
6"
REMOVE AND REUSE WELLHEAD ASSEMBLY
EXISTING COVER SOIL
AND WASTE
SECTION VIEW
PLAN VIEW
NOTES:
1. GRAVEL PAD TO BE CENTERED ON SINGLE PENETRATIONS.
2. 72" MARKER POST SHALL HAVE WELL ID. PLACE TWO MARKERS AT EACH
WELL AT OPPOSITE CORNERS.
GRAVEL PAD
NOT TO SCALE
72" FIBERGLASS UTILITY
MARKER WITH WELL ID
72" FIBERGLASS UTILITY
MARKER WITH WELL ID
PIPE TO HEADER
(IF BURIED)
WELLHEAD
8 OZ. GEOTEXTILE
6'
4"
6'
3' 1'-6"1'-6"
A A
SECTION A-A
NOTES:
1. THIS DETAIL IS TYPICAL FOR ALL 6" DIA. SDR 17 HDPE PIPE
PENETRATIONS.
2. A MINIMUM 1' OF EXCESS SLACK BETWEEN CLAMPS AND WELD
SHALL BE PROVIDED.
" V
EG
ET
AT
IV
E
SU
PP
O
R T
SO
IL
40-MIL LLDPE
GEOMEMBRANE PIPE
BOOT WELDED TO 40-MIL
LLDPE GEOMEMBRANE
CAP LINER (SEE NOTE 2)
4"
GRAVEL
2"
1/4"x6" MINIMUM CLOSED
CELL NEOPRENE SPONGE
SC 42-M OR CORD
PACKING
3'
40 MIL LLDPE LINER
LLDPE CLOSURE LINER PENETRATION
NOT TO SCALE
1/8"x1/2" WIDE STAINLESS STEEL CLAMP (TYP. OF 2)1/4"x6" MINIMUM CLOSED
CELL NEOPRENE
SPONGE SC 42-M
OR CORD PACKING
6" SDR 17 HDPE
SOLID WALL PIPE
6" SDR 17 HDPE
SOLID WALL PIPE
GRAVEL PAD
(SEE DETAIL THIS SHEET)
1/8"x1/2" WIDE STAINLESS
STEEL CLAMP (TYP. OF 2)
CAP SUBGRADE
GENERAL BACKFILL
LANDFILL GAS EXTRACTION WELL
EXISTING GRADE (VARIES)
2'
FOR INFORMATION ONLY - NOT IN CONTRACT
LE
P
AT
H : Q
:\P R
O
JE
C
TS
\1
H
W D
C L
FG
E
XP
AN
SI
O
N \C
AD
\P
R O
D U
C
TI
O N
\D
ES
IG
This is the start of the file's text. The full file is on GovTribe.