27-24-SPS Drawings.pdf
PDF 8 MB Posted
- Solicitation number
- BD-27-1165-COSPS-COSPS-135508
- Issued by
- Massachusetts
About this file
This is a construction drawings document for the Bates Elementary School MSBA Accelerated Repair Program roof replacement project located at 53 Liberty Hill Avenue, Salem, Massachusetts 01970. The project, identified as MSBA Project #202402580003, involves the removal and replacement of roofing systems across multiple roof levels and configurations. The scope includes demolition of existing EPDM membranes, insulation, and associated components, followed by installation of new 60 mil PVC roof membranes with polyisocyanurate insulation designed to achieve a minimum U-value of 0.032. The work encompasses approximately 42,000 square feet of roofing area across four primary roof system types (R1-R4), with additional work including new gutters, downspouts, flashing, roof hatches, walkway pads, and coordination of HVAC equipment relocation to meet manufacturer warranty requirements. Construction documents were submitted on November 18, 2026, by Skanska USA Building Inc. as the project manager on behalf of Salem Public Schools.
The project requires compliance with the 2021 International Building Code and Massachusetts Building Code (CMR 780), with roof assemblies rated for Class AC fire classification minimum and wind uplift resistance to 120 mph. The existing building, originally constructed in 1969 with additions and renovations in 1999, is classified as Type IIB construction. The estimated project cost is $2,815,315.00, representing approximately 11 percent of the building's full and fair cash value of $26,614,441.49, with work including new masonry counterflashing installation, vertical membrane installations totaling 260 linear feet, and counterflashing installations totaling 515 linear feet. The project includes coordination with multiple trade subcontractors, including mechanical [231], masonry [401], and electrical [261] contractors, with specific responsibilities identified for HVAC equipment disconnection/reconnection and new flashing installations. The roof is designated as photovoltaic-ready with designated solar installation areas totaling approximately 14,000 square feet and varying reserve structural capacity allocations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 27-24-SPS IFB Manual - Bates Elementary School Roof.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING LIST
GENERAL
G-001 COVER SHEET
G-002 SYMBOLS, ABBREVIATIONS & GENERAL NOTES
G-010 BUILDING CODE SUMMARY AND SITE PLAN
ARCHITECTURAL DEMOLITION
AD-130 OVERALL ROOF PLAN - DEMOLITION
AD-511 ROOF DETAILS - DEMOLITION
AD-512 ROOF DETAILS - DEMOLITION
AD-513 ROOF DETAILS - DEMOLITION
ARCHITECTURAL
A-130 OVERALL ROOF PLAN - NEW WORK
A-511 ROOF DETAILS
A-512 ROOF DETAILS
A-513 ROOF DETAILS
STRUCTURAL
S-100 ROOF STRUCTURAL CAPACITY
PLUMBING
PD-100 PLUMBING ROOF PLAN - DEMOLITION
P-200 PLUMBING ROOF PLAN - NEW WORK
MECHANICAL
MD-100 MECHANICAL ROOF PLAN - DEMOLITION
M-200 MECHANICAL ROOF PLAN - NEW WORK
ELECTRICAL
ED-100 ELECTRICAL ROOF PLAN - DEMOLITION
E-200 MECHANICAL ROOF PLAN - NEW WORK
L
O N
G W
A T
E R
D R
N O
R W
E L
L
M A
H
A R
V A
R D
S T
W
O R
C E
S T
E R
M
A
.8
.9 h a b e e b a rc h .c o m
A
R
C
H
I
E
A
B
B
SCALE:
PROJECT NO:
DATE:
DRAWN BY:
CHECKED BY:
P L O
T T
E D
O N
B
C
A
T h is B o rd e r is in te n d e d f o r a x s h e e t.
If p ri n te d s h e e t s iz e d iff e rs re fe r to g ra p h ic b a r s c a le s o n ly
C o p y ri g h t H a b e e b
A s s o c ia te s A rc h it e c ts
D
/1
/2
:4 :2
A
M
G-001
COVER SHEET
2505.01
11/18/26
E.G.
JM
L
IB
E
R T
Y H
IL
L
A V
E N
U E
S A
L E
M
M
B A
T E
S E
L E
M E
N T
A R
Y S
C H
O O
L
M S
B A
A C
C E
L E
R A
T E
D R
E P
A
IR
P R
O G
R A
M R
O O
F R
E P
L A
C E
M E
N T
HABEEB & ASSOCIATES ARCHITECTS
ARCHITECT
www.habeebarch.com
150 LONGWATER DRIVE
NORWELL, MA 02061
MSBA PROJECT #
HABEEB & ASSOCIATES ARCHITECTS
www.habeebarch.com
150 LONGWATER DRIVE
NORWELL, MA 02061
TEL: 781-871-9804
TEL: 781-871-9804
OWNER/AWARDING AUTHORITY (NOT TO SCALE)LOCUS PLAN
STRUCTURAL
BATES ELEMENTARY SCHOOL
MSBA ACCELERATED REPAIR PROGRAM
ROOF REPLACEMENT
53 LIBERTY HILL AVENUE
SALEM, MA 01970
NOVEMBER 18, 2026
CONSTRUCTION DOCUMENTS
SUBMISSION
SKANSKA USA BUILDING INC.SALEM PUBLIC SCHOOLS
202402580003
OWNER PROJECT MANAGER
29 HIGHLAND AVE.
SALEM, MA 01970
劕匫 劕匫
TEL: 978-740-1212
salemk12.org
101 SEAPORT BOULEVARD, SUITE 200
BOSTON, MA 02210
劕匫 劕匫
TEL: 617-512-5605
usa.skanska.com
N
PROJECT LOCATION
M S
B A
P R
O
JE
C T
M
S B
A P
R O
JE
C
T
REVISIONS
Δ MM-DD-YYYY DESCRIPTION
ALUMINUM
GLASS BRICK
(REFER TO DETAILS FOR
ACCURATE COURSING LINES)
BRICK
SHEET METAL CMU
(REFER TO DETAILS FOR
ACCURATE COURSING LINES)
SYMBOLS
MASONRY BLOCK
CRUSHED STONE / GRAVEL
EARTH - ELEVATION / DETAIL
EARTH / COMPACT FILL
GYPSUM WALLBOARD
HARDWOOD
RIGID INSULATION
ROUGH LUMBER
BATT INSULATION
CERAMIC TILE
ACOUSTICAL TILE
MATERIALS (SECTION VIEWS)
MATERIALS (ELEVATION VIEWS)
GLAZED BRICK METAL LATHE & PLASTER
METAL STUD PARTITION PLASTIC
CARPET & PAD
STEEL CERAMIC TILE
MEDIUM DENSITY FIBERBOARD PLYWOOD
CONCRETE
CONCRETE RIGID INSULATION
L
O N
G W
A T
E R
D R
N O
R W
E L
L
M A
H
A R
V A
R D
R
C E
S T
E R
M
A
.8
.9 h a b e e b a rc h .c o m
A
B
PROJECT NO:
DATE:
DRAWN BY:
CHECKED BY:
P L O
T T
E D
O N
B
C
A
T h is B o rd e r is in te n d e d f o r a x s h e ri n te d s h e e t s iz e d iff e rs re fe r to g ra p h ic b a r s c a le s o n ly
C o p y ri g h t H a b e e b
A s s o c ia te s A rc h it e c ts
D
1 1/2" = 1'-0"
/1
/2
:4 :2
A
M
G-002
SYMBOLS,
ABBREVIATIONS &
GENERAL NOTES
2505.01
11/18/26
E.G.
JM
L
IB
E
R T
Y H
IL
L
A V
E N
U E
S A
L E
M
B A
T E
S E
L E
M E
N T
A R
Y S
C H
O O
L
M S
B A
A C
C E
L E
R A
T E
D R
E P
A
IR
P R
O G
R A
M R
O O
F R
E P
L A
C E
M E
N T
ABBREVIATIONS
GENERAL DRAWING ANNOTATIONS
DIMENSIONING LINE
REVISION ISSUE NUMBER
ITEMS WITHIN CLOUD
HAVE BEEN REVISED
INDICATES VIEW NUMBER
(KEY ON PLANS & ELEVATIONS)
INDICATES SHEET NUMBER
INDICATES VIEW NUMBER
INDICATES SHEET NUMBER
INDICATES VIEW NUMBER
INDICATES SHEET NUMBER
DETAIL REFERENCE SHEET
DETAIL REFERENCE TYPE
(IF APPLICABLE)
DETAIL NUMBER
DENOTES ALIGNMENT OF
INDICATED SURFACESALIGN
KEYNOTE TAG
-REFER TO KEYNOTE LEGEND
INDICATES ROOM NAME
DENOTES ACCESSORY
ROOM/AREA (WHERE PRESENT)
DENOTES ROOM /AREA
NUMBER
DENOTES FLOOR / LEVEL
NUMBER
COLUMN GRID
CENTERLINES
NORTH ARROW:
MATCH LINE (FOR DIVIDED
FLOOR PLAN VIEWS)
TRUE NO
RTH
0 2' 4' 8'
SCALE:
INDICATES BUILDING DATUM -
REFER TO GENERAL NOTE #9
WALL SECTION VIEW:
INDICATES VIEW NUMBER
(KEY ON PLANS & ELEVATIONS)
INDICATES SHEET NUMBER
BUILDING SECTION VIEW:
INTERIOR ELEVATION VIEW:
EXTERIOR ELEVATION VIEW:
COLUMN GRID
DESIGNATION
LEVEL INDICATOR:
DENOTES PLAN/PROJECT
NORTH
ENLARGED PLAN/DETAIL VIEW:
ROOM TAG:
VIEW TITLE:
W/ SCALE &
GRAPHIC SCALE
##/A-110A
REFERENCE FOR VIEW
CONTINUATION
GENERAL NOTES
NAME OF LEVEL
100'-0" (###.##)
1. "N.I.C." IS NOTED ON ITEMS NOT IN THE CONTRACT. "BY OWNER" AND/OR "OTHERS" ARE NOTED ON ITEMS TO BE
PROVIDED UNDER SEPARATE CONTRACT BY THE TENANT.
2. WHERE A TYPICAL CONDITION IS DETAILED AND/OR NOTED, IT SHALL BE UNDERSTOOD THAT ALL LIKE OR SIMILAR
CONDITIONS SHALL BE THE SAME UNLESS SPECIFICALLY DETAILED OR NOTED OTHERWISE.
3. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE SHOWN ON DRAWINGS. THE CONTRACTOR SHALL REQUEST CLARIFICATION FROM THE ARCHITECT OF ANY DIMENSIONAL REQUIREMENT AS NECESSARY FOR THE PROPER EXECUTION OF ANY AFFECTED WORK PRIOR TO THE COMMENCEMENT OF SUCH
WORK.
4. THE TERM "AFFECTED WORK" AS USED IN THESE GENERAL NOTES SHALL BE DEEMED TO BE ANY REQUIREMENT OF THE CONSTRUCTION DOCUMENTS AND SHALL BE FURTHER DEEMED TO INCLUDE THE PROCUREMENT OF ANY AND ALL MATERIALS, TOOLS, LABOR, ETC., AS FURTHER DESCRIBED IN THE SPECIFICATIONS, REQUIRED FOR THE
EXECUTION OF SUCH WORK.
5. THE CONTRACTOR SHALL REPORT ANY DISCREPANCY WITHIN THE CONTRACT DOCUMENTS TO THE ARCHITECT FOR CLARIFICATION AND/OR RESOLUTION PRIOR TO THE COMMENCEMENT OF ANY AFFECTED WORK. SUCH CLARIFICATION AND/OR RESOLUTION SHALL BE PROVIDED BY THE ARCHITECT PRIOR TO THE COMMENCEMENT OF
ANY AFFECTED WORK.
6. THE CONTRACTOR SHALL VERIFY ALL EXISTING SITE, BUILDING, AND UTILITY CONDITIONS, AND SHALL REPORT ANY DISCREPANCIES BETWEEN SUCH EXISTING CONDITIONS AND THE REQUIREMENTS OF THE CONTRACT DOCUMENTS TO THE ARCHITECT FOR CLARIFICATION AND/OR RESOLUTION, PRIOR TO THE COMMENCEMENT OF ANY AFFECTED WORK. THE ARCHITECT SHALL PROVIDE SUCH CLARIFICATION AND/OR RESOLUTION PRIOR TO THE
COMMENCEMENT OF ANY AFFECTED WORK.
7. NOMINAL DIMENSIONS FOR LUMBER AND WOOD TRIM ARE NOTED IN THE FOLLOWING FORMAT: 1 x 4, 5/4 x 4, 2 x 4, ETC. ACTUAL DIMENSIONS, WHERE REQUIRED, ARE NOTED AS 1" x 2" ETC.
8. VERTICAL DATUM: ARCHITECTURAL DRAWINGS REFERENCE THE MAIN FLOOR CLOSEST TO GROUND LEVEL AS
100'-0." ALL ARCHITECTURAL SPOT ELEVATIONS AS REFERENCED BY MARKER:
ARE RELATIVE TO THIS ARCHITECTURAL DATUM. THE NUMBER IN PARENTHESIS, WHERE USED, IS INTENDED TO CONVEY THE CIVIL DATUM IN DECIMAL FEET. REFER TO CIVIL DRAWINGS FOR BENCHMARK AND ACTUAL GRADE
ELEVATIONS.
ROOF PLAN - DEMOLITION
1/4" = 1'-0"
A-501
TYP
A-201
A-301
A-310
A
1ST FLOOR
EL:100'-0" (105.00)
101A
CLASSROOM
14 A-410
1 1/8"
INDICATES CIVIL DATUM -
REFER TO GENERAL NOTE #9
FILED SUB-BID LEGEND:
[###] FILED SUB-BID CATEGORY - SPECIFICATION REFERENCE
[401] MASONRY WORK - REFER TO SPEC SECTION 04 0001
[221] PLUMBING - REFER TO SPEC SECTION 22 0001
[231] HVAC - REFER TO SPEC SECTION 23 0001
[261] ELECTRICAL - REFER TO SPEC SECTION 26 0001
NOTE:
ALL OTHER WORK NOT INCLUDED IN FILED SUB BIDDERS SCOPE SHALL BE THE RESPONSIBILITY OF
THE GENERAL CONTRACTOR
DETAIL (SECTION VIEW):?
A-501
@ AT
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
ALUM ALUMINUM
ANCH ANCHOR
APPROX APPROXIMATE(LY)
BD BOARD
BFE BOTTOM OF FOOTING
ELEVATION
BIT BITUMINOUS
BKSP BACKSPLASH
BKT BRACKET
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BOD BOTTOM OF DECK
BSMT BASEMENT
CAB CABINET
CB CHALKBOARD OR CATCH
BASIN
CEM CEMENT
CER/CT CERAMIC/ CERAMIC TILE
CG CORNER GUARD
CHP CONCRETE HOUSEKEEPING
PAD
CI CONTINUOUS INSULATION
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLKG CAULKING
CLOS CLOSET
CLR CLEAR(ANCE)
CMU CONCRETE MASONRY UNIT
CO CLEAR OPENING
COL COLUMN
CONC CONCRETE (PORTLAND
CEMENT)
COND CONDITION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CORR CORRIDOR
CR COLD ROLLED
CTOP COUNTERTOP
CU CUBIC, COPPER
CUH CABINET UNIT HEATER
" DITTO (REPEAT)
DA DOUBLE ACTING
DAFS DIRECT APPLIED FINISH
SYSTEM
DEMO DEMOLISH, DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DN DOWN
DO DOOR OPENING
DR DOOR
DS DOWNSPOUT
DSP DISPENSER
DW DISHWASHER
DWG(S) DRAWING(S)
EA EACH
ED EDUCATION
EDSP END SPLASH
EF EXHAUST FAN
EIFS EXTERIOR INSULATED FINISH
SYSTEM
EJ EXPANSION JOINT
EL ELEVATION (GRADE)
ELEC ELECTRIC(AL)
ELEV ELEVATION (FACADE)
EOD EDGE OF DECK
EP ELECTRIC PANEL
EPDM ETHYLENE PROPYLENE DIENE
MONOMER
EQ EQUAL
EQP,
EQUIP
EQUIPMENT
ES EACH SIDE
ETR EXISTING TO REMAIN
EXIST EXISTING
EXP EXPOSED
EXT EXTERIOR
EXTIN EXTINGUISHER
FB FLAT BAR
FC FIRE CODE
FCP FIBER CEMENT PANEL
FD FLOOR DRAIN
FDC FIRE DEPARTMENT
CONNECTION
FDV FIRE DEPARTMENT VALVE
FDVC FIRE DEPARTMENT VALVE
CABINET
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FACTORY FINISH
FFE FINISH FLOOR ELEVATION
FH FLAT HEAD
FHC FIRE HOSE CABINET
FIN FINISH
FL FLOOR, FLOORING
FLASH FLASHING
FLUOR FLUORESCENT
FO FRAMED OPENING
FOS FACE OF STEEL / STUD
FP FIREPROOF(ING)
FR FIRE RESISTANT
FS FIRE SHIELD
FSZ FULL SIZE
FT FEET, FOOT
FTR FIN TUBE RADIATOR
FUR FURRING
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GFCMU GROUND FACED CMU
GL GLASS
GMU GLAZED MASONRY UNIT
GR GRADE
GSU GLAZED STRUCTURAL UNIT
GWB GYPSUM WALL BOARD
GYP GYPSUM
HC HANDICAP(PED)
HD HEAD, HIGH DENSITY
HDR HEADER
HDWD HARDWOOD
HDWR HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HORZ HORIZONTAL
HP HIGH POINT
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATION & AIR
CONDITIONING
ID INSIDE DIAMETER
IN INCH OR INCHES
IN2 SQUARE INCH
IN3 CUBIC INCHES
INCAN INCANDESCENT
INFIL INFILTRATION
INSUL INSULATION
INT INTERIOR
INV INVERT
JAN JANITOR
JB JUNCTION BOX
JST JOIST
JT JOINT
LAM LAMINATE(D)
LBS / # POUNDS
LCC LEAD COATED COPPER
LDP LAMINATED DRYWALL
PARTITION
LGMF LIGHT GAUGE METAL
FRAMING
LGTH LENGTH
LIWT LIGHT WEIGHT
LOW LIMIT OF WORK
LP LOW POINT
LTG LIGHTING
LVR LOUVER
MACH MACHINE
MAS MASONRY
MAT MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MD METAL DOOR
MECH MECHANICAL
MEMBR MEMBRANE
MFGR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MMC MISC METAL CONTRACTOR
MO MASONRY OPENING
MT METAL THRESHOLD
MTD MOUNTED
MTL METAL
NAT NATURAL
NC NONCORROSIVE
NIC NOT IN CONTRACT
NO / # NUMBER
NOM NOMINAL
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OH OPPOSITE HAND
OPER OPERATE
OPNG OPENING
OVHD OVERHEAD
OZ OUNCES
PARTN PARTITION
PC PRECAST CONCRETE
PERIM PERIMETER
PERP PERPENDICULAR (TO)
PL PLATE
PLAS PLASTER
PLUMB PLUMBING
PLWD PLYWOOD
PNL PANEL
POL POLISHED
PR PAIR
PT PRESSURE TREATED
QT QUARRY TILE
QTY QUANTITY
R RISER
R= RADIUS
RAD ENCL RADIATOR ENCLOSURE
RB RESILIENT BASE
RD ROOF DRAIN
REF REFRIGERATOR
REINF REINFORCING
REQD REQUIRED
RESIL RESILIENT
RET RETAINING
RJ RELIEVING JOINT
RL ROOF LADDER
RM ROOM
RO ROUGH OPENING
RWL RAIN WATER LEADER
S, STR STRUCTURAL
SAM SELF ADHERED MEMBRANE
SC SCUPPER
SCHED SCHEDULE
SCN SCREEN
SD STORM DRAIN
SECT SECTION
SH SHELF, SHELVING,
SINGLE-HUNG
SHT SHEET
SIGS SILICON IMPREGNATED
GYPSUM SHEATHING
SIM SIMILAR
SIP STRUCTURAL INSULATED
PANEL
SLID SLIDING
SMV SMOKE-VENTING HATCH
SPEC SPECIFICATIONS
SPF SPECIFIED
SPK SPEAKER
SPR SPRINKLER
SQ SQUARE FEET
SS STAINLESS STEEL
ST STREET
STD STANDARD
STIFF STIFFENER
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SY SQUARE YARD
T TREAD
T&G TONGUE & GROOVE
TB TACK BOARD
TBLE TABLE
TC TERRA COTTA
TD TRENCH DRAIN
TEL TELEPHONE
TERR TERRAZZO
TG TEMPERED GLASS
THK THICKNESS
THRESH THRESHOLD
TLT TOILET
TO TOP OF
TOB TOP OF BLOCKING
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOR TOP OF RAIL
TOS TOP OF STEEL
TOW TOP OF WALL
TWR TOWER
TYP TYPICAL
UC UNDERCUT
UL UNDERWRITERS
LABORATORY
UNO / UON UNLESS NOTED OTHERWISE /
UNLESS OTHERWISE NOTED
UPR UPPER
UV UNIT VENTILATOR,
ULTRAVIOLET
V VOLT(AGE)
VC VINYL CLAD
VCT VINYL COMPOSITE TILE
VENT VENTILATOR
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VMI VERTICAL MEMBRANE INSERT
VP VENT PIPE
VS VINYL SHEET
VT VINYL TILE
VWC VINYL WALL COVERING
W WIDE, WIDE FLANGE
W/ WITH
W/O, WO WITHOUT
WB WHITE BOARD (MARKER
BOARD)
WBO WORK BY OTHERS
WBOR WORK BY OWNER
WC WATER CLOSET
WD WOOD
WD WINDOW DIMENSION
WG WIRE GLASS, WALL GUARD
WH WALL-HUNG
WI WROUGHT IRON
WIND WINDOW
WO WINDOW OPENING
WP WATERPROOFING
WT WEIGHT
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
x INDICATES "TIMES" OR "BY"
YD YARD
Z Z STUD (STRUCTURAL SHAPE)
TYP1
ROOF SYSTEM REPLACEMENT AND HVAC REPLACEMENT - CODE ANALYSIS
REFERENCED CODES
THE BUILDING SHALL COMPLY AND/OR CONFORM TO THE FOLLOWING CONSTRUCTION
CODES, SUPPLEMENTS, STANDARDS GUIDELINES, AND ALL STANDARDS REFERENCED THEREIN:
PROJECT SUMMARY
THE PROJECT CONSISTS OF THE REMOVAL AND REPLACEMENT OF THE ROOFING SYSTEMS AS INDICATED ON PROJECT DRAWINGS AND PER THE REQUIREMENTS OF THE FOLLOWING CODES, REGULATIONS AND ALL RELEVANT
STANDARDS REFERENCED THEREIN:
1. CMR 780 MASSACHUSETTS STATE BUILDING CODE, TENTH EDITION (2021 INTERNATIONAL BUILDING CODE WITH
MASSACHUSETTS AMENDMENTS)
• CHAPTER 34 EXISTING BUILDING CODE (2021 INTERNATIONAL EXISTING BUILDING CODE WITH MASSACHUSETTS
AMENDMENTS)
• CHAPTER 13 COMMERCIAL ENERGY EFFICIENCY (2021 INTERNATIONAL ENERGY CONSERVATION ENERGY CODE
AND ASHRAE 90.1-2019 WITH MASSACHUSETTS AMENDMENTS)
• 225 CMR 23.00 MASSACHUSETTS FRONT END AMENDMENTS TO INTERNATIONAL ENERGY CONSERVATION CODE
• 2021 MASSACHUSETTS STRETCH ENERGY CODE -2023 COMMERCIAL AMENDMENTS TO IECC 2021.
2. CMR 521 MASSACHUSETTS ARCHITECTURAL ACCESS BOARD RULES AND REGULATIONS.
BUILDING USE AND OCCUPANCY
USE GROUP: EDUCATIONAL
YEAR BUILT: 1969, WITH AN ADDITION AND RENOVATION IN 1999
BUILDING CONSTRUCTION CLASSIFICATION: 2021 IBC: TYPE IIB
FIRE RATING OF ROOF ASSEMBLY: NON-RATED
CMR 780 MASSACHUSETTS STATE BUILDING CODE, TENTH EDITION ANALYSIS
CHAPTER 34: EXISTING BUILDINGS:
SECTION 101.1 SCOPE.
THE PROVISIONS OF THE INTERNATIONAL EXISTING BUILDING CODE - 2021 SHALL APPLY TO THE
REPAIR, ALTERATION, CHANGE OF OCCUPANCY, ADDITION TO AND RELOCATION OF EXISTING
BUILDINGS.
CHAPTER 6 CLASSIFICATION OF WORK
SECTION 601.1 SCOPE.
THE PROVISIONS OF THIS CHAPTER SHALL BE USED IN CONJUNCTION WITH CHAPTERS 7 THROUGH 12
AND SHALL APPLY TO THE ALTERATIONS, ADDITION AND CHANGE OF OCCUPANCY OF EXISTING
STRUCTURES, INCLUDING HISTORIC AND MOVED STRUCTURES, AS REFERENCED IN SECTION 301.3.2.
THE WORK PERFORMED ON AN EXISTING BUILDING SHALL BE CLASSIFIED IN ACCORDANCE WITH THIS
CHAPTER.
SECTION 602 ALTERATION - LEVEL 1.
SECTION 602.1 SCOPE.
LEVEL 1 ALTERATIONS INCLUDE THE REMOVAL AND REPLACEMENT OF THE COVERING OF EXISTING MATERIALS, ELEMENTS, EQUIPMENT OR FIXTURES USING NEW MATERIALS. ELEMENTS, EQUIPMENT OR
FIXTURES THAT SERVE THE SAME PURPOSE.
SECTION 602.2 APPLICATION.
LEVEL 1 ALTERATIONS SHALL COMPLY WITH THE PROVISIONS OF CHAPTER 7.
SECTION 705 REROOFING.
SECTION 705.1 GENERAL:
MATERIAL AND METHODS OF APPLICATION USED FOR RECOVERING OR REPLACING AN EXISTING ROOF COVERING SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER 15 OF THE INTERNATIONAL BUILDING
CODE.
INTERNATIONAL BUILDING CODE 2021
SECTION 1504 PERFORMANCE REQUIREMENTS:
ROOF MATERIAL PERFORMANCE AND INSTALLATION WILL BE DESIGNED AND INSTALLED IN
ACCORDANCE WITH CHAPTER 15. FOR THE LOW SLOPE ROOFS WE PROPOSE TO USE A FULLY
ADHERED SINGLE-PLY PVC MEMBRANE ROOF SYSTEM. PER SECTION 1504.8 LOW SLOPED ROOFS MUST RESIST IMPACT DAMAGE BASED ON THE RESULTS OF TEST CONDUCTED IN ACCORDANCE WITH ASTM D 3746, ASTM D 4272. ROOF COVERINGS SHOULD ALSO BE IN ACCORDANCE WITH FM4470. THE ROOFING
MANUFACTURES WILL BE REQUIRED TO MEET THE PERFORMANCE AND THE WIND UPLIFT
REQUIREMENTS OF THE CODE FOR WINDS UP TO 120 MPH.
SECTION 1505 FIRE CLASSIFICATION
TABLE 1505.1 REQUIRES A MINIMUM FIRE RESISTANCE CLASSIFICATION RATING OF AC FOR TYPE IIB
BUILDINGS.
FOR THE LOW SLOPE ROOFS WE PROPOSE TO USE A FULLY ADHERED SINGLE-PLY PVC MEMBRANE
ROOF SYSTEM WITH A CLASS AC RATING OR BETTER.
SECTION 1506 MATERIALS
SECTION 1506.2 MATERIAL SPECIFICATIONS AND PHYSICAL CHARACTERISTICS.
ROOFING COVERING MATERIALS SHALL CONFORM TO THE APPLICABLE STANDARDS LISTED IN THE
CHAPTER.
SECTION 1506.3 PRODUCT IDENTIFICATION.
ROOF-COVERING MATERIALS SHALL BE DELIVERED IN PACKAGES BEARING THE MANUFACTURER'S
IDENTIFYING MARKS AND APPROVED TESTING AGENCY LABELS REQUIRED IN ACCORDANCE WITH
SECTION 1505. BULK SHIPMENTS OF MATERIALS SHALL BE ACCOMPANIED WITH THE SAME
INFORMATION ISSUED IN THE FORM OF A CERTIFICATE OR ON A BILL OF LADING BY THE
MANUFACTURER.
SECTION 1507 REQUIREMENTS FOR COVERINGS.
ROOF COVERINGS SHALL BE APPLIED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF THIS
SECTION AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
SECTION 1508 ROOF INSULATION
SECTION 1508.1 GENERAL.
THE USE OF ABOVE-DECK THERMAL INSULATION SHALL BE PERMITTED PROVIDED THAT SUCH
INSULATION IS COVERED WITH AN APPROVED ROOF COVERING AND PASSES THE TESTS OF NFPA 276
OR UL 1256 WHEN TESTED AS AN ASSEMBLY.
SECTION 1512.2 ROOF REPLACEMENT.
ROOF REPLACEMENT SHALL INCLUDE THE REMOVAL OF ALL EXISTING LAYERS OF ROOF ASSEMBLY
MATERIALS DOWN TO ROOF DECK.
EXCEPTION: WHERE THE EXISTING ROOF ASSEMBLY INCLUDES AN ICE BARRIER THAT IS ADHERED TO THE ROOF DECK, THE EXISTING ICE BARRIER MEMBRANE SHALL BE PERMITTED TO REMAIN IN PLACE
AND COVERED WITH AN ADDITIONAL LAYER OF ICE BARRIER MEMBRANE IN ACCORDANCE WITH
SECTION 1507.
INTERNATIONAL ENERGY CONSERVATION CODE, 2021
CHAPTER 5 [CE] EXISTING BUILDINGS.
SECTION C501.1.1 EXISTING BUILDINGS
EXCEPT AS SPECIFIED IN THIS CHAPTER, THIS CODE SHALL NOT BE USED TO REQUIRE THE REMOVAL, ALTERATION OR ABANDONMENT, NOR PREVENT THE CONTINUED USE AND MAINTENANCE OF, EXISTING BUILDINGS OR BUILDING SYSTEM LAWFULLY IN EXISTENCE AT THE TIME OF ADOPTION OF
THIS CODE.
CMR 521 MASSACHUSETTS ARCHITECTURAL ACCESS BOARD RULES AND REGULATIONS
3.00: JURISDICTION:
3.3 EXISTING BUILDINGS
ALL ADDITIONS TO, RECONSTRUCTION, REMODELING, AND ALTERATIONS OR REPAIRS OF EXISTING PUBLIC BUILDINGS OR FACILITIES, WHICH REQUIRE A BUILDING PERMIT, OR WHICH ARE SO DEFINED BY A STATE OR LOCAL INSPECTOR, SHALL BE GOVERNED BY ALL APPLICABLE SUBSECTIONS IN 521 CMR 3.00: JURISDICTION.
3.3.1: IF THE WORK BEING PERFORMED AMOUNTS TO LESS THAN 30% OF THE FULL AND FAIR CASH VALUE OF THE
BUILDING AND:
A. IF THE WORK COSTS LESS THAN $100,000, THEN ONLY THE WORK BEING PERFORMED IS REQUIRED TO
COMPLY WITH 521 CMR
OR
B. IF THE WORK COSTS $100,000 OR MORE, THEN THE WORK BEING PERFORMED IS REQUIRED TO COMPLY WITH 521 CMR. IN ADDITION, AN ACCESSIBLE PUBLIC ENTRANCE AND AN ACCESSIBLE TOILET ROOM, TELEPHONE, DRINKING FOUNTAIN (IF TOILETS, TELEPHONES AND DRINKING FOUNTAINS ARE
PROVIDED) SHALL ALSO BE PROVIDED IN COMPLIANCE WITH 521 CMR. EXCEPTION: WHETHER
PERFORMED ALONE OR IN COMBINATION WITH EACH OTHER, THE FOLLOWING TYPES OF
ALTERATIONS ARE NOT SUBJECT TO 521 CMR 3.3.1, UNLESS THE COST OF THE WORK EXCEEDS $500,000 OR UNLESS WORK IS BEING PERFORMED ON THE ENTRANCE OR TOILET. (WHEN PERFORMING EXEMPTED WORK, A MEMO STATING THE EXEMPTED WORK AND ITS COSTS MUST BE FILED WITH THE
PERMIT APPLICATION OR A SEPARATE BUILDING PERMIT MUST BE OBTAINED.)
A. CURB CUTS: THE CONSTRUCTION OF CURB CUTS SHALL COMPLY WITH 521 CMR 21.00: CURB
CUTS.
B. ALTERATION WORK WHICH IS LIMITED SOLELY TO ELECTRICAL MECHANICAL, OR PLUMBING
SYSTEMS; TO ABATEMENT OF HAZARDOUS MATERIALS; OR RETROFIT OF AUTOMATIC
SPRINKLERS AND DOES NOT INVOLVE THE ALTERATION OF ANY ELEMENTS OR SPACES
REQUIRED TO BE ACCESSIBLE UNDER 521 CMR. WHERE ELECTRICAL OUTLETS AND CONTROLS
ARE ALTERED, THEY MUST COMPLY WITH 521 CMR.
C. ROOF REPAIR OR REPLACEMENT, WINDOW REPAIR OR REPLACEMENT, REPOINTING AND
MASONRY REPAIR WORK.
D. WORK RELATING TO SEPTIC SYSTEM REPAIRS, (INCLUDING TITLE V, 310 CMR 15.00,
IMPROVEMENTS) SITE UTILITIES AND LANDSCAPING.
3.3.2: IF THE WORK PERFORMED, INCLUDING THE EXEMPTED WORK, AMOUNTS TO 30% OR MORE OF THE FULL AND FAIR CASH VALUE (SEE 521 CMR 5.00) OF THE BUILDING THE ENTIRE BUILDING IS REQUIRED TO COMPLY WITH
521 CMR.
A. WHERE THE COST OF CONSTRUCTING AN ADDITION TO A BUILDING AMOUNTS TO 30% OR MORE OF THE FULL AND FAIR CASH VALUE OF THE EXISTING BUILDING, BOTH THE ADDITION AND THE EXISTING
BUILDING MUST BE FULLY ACCESSIBLE.
5.00: DEFINITIONS:
5.1 FULL AND FAIR CASH VALUE OF THE BUILDING
THE ASSESSED VALUATION OF A BUILDING (NOT INCLUDING THE LAND) AS RECORDED IN THE ASSESSOR’S OFFICE OF THE MUNICIPALITY AT THE TIME THE BUILDING PERMIT IS ISSUED AS EQUALIZED AT 100% VALUATION. THE 100% EQUALIZED ASSESSED VALUE SHALL BE BASED UPON MASSACHUSETTS DEPARTMENT OF REVENUE’S
DETERMINATION OF THE PARTICULAR CITIES OR TOWN’S ASSESSMENT RATIO.
FOR VALUE ON YEAR 2026, THE CITY OF SALEM ASSESSMENT FOR THE BUILDING IS $25,017,558.00. THE 2024 EQUALIZED VALUATION REPORT PUBLISHED BY THE MASSACHUSETTS DIVISION OF LOCAL SERVICES INDICATES THE ASSESSMENT RATIO FOR THE NON-RESIDENTIAL PROPERTY IS 0.94, THEREFORE THE FULL AND FAIR CASH VALUE
OF THE BUILDING IS:
$25,017,558.00/.94 = $26,614,441.49
THE COST OF THE WORK IS ESTIMATED TO BE $2,815.315.00 (EXCLUDING ESTIMATED ADA UPGRADE COST) WHICH REPRESENTS 11% OF THE FULL AND FAIR CASH VALUE OF THE BUILDING. PER THE REQUIREMENTS OUTLINED IN 521 CMR 3.3.1 ADA PARKING DESIGNATION AND SIGNAGE FOR ACCESS TO THE EXISTING ADA ENTRANCE ARE BOTH EXISTING TO REMAIN AND BOTH COMPLY WITH 521 CMR. THERE IS AN EXISTING ADA TOILET ROOM THAT ALSO
COMPLIES 521 CMR.
EXCEPTIONS:
1. ROOF REPLACEMENT OR ROOF RECOVER OF EXISTING LOW-SLOPE ROOF COVERINGS SHALL
NOT BE REQUIRED TO MEET THE MINIMUM DESIGN SLOPE REQUIREMENT OF 1/4 UNIT VERTICAL PER 12 UNITS HORIZONTAL (2 PERCENT) IN SECTION 1507 OF THE INTERNATIONAL BUILDING
CODE FOR ROOFS THAT PROVIDE POSITIVE ROOF DRAINAGE.
2. RECOVERING OR REPLACING AN EXISTING ROOF COVERING SHALL NOT BE REQUIRED TO MEET
THE REQUIREMENT FOR SECONDARY (EMERGENCY OVERFLOW) DRAINS OR SCUPPERS IN
SECTION 1502 OF THE INTERNATIONAL BUILDING CODE FOR ROOFS THAT PROVIDE POSITIVE
ROOF DRAINAGE. FOR THE PURPOSES OF THIS EXCEPTION, EXISTING SECONDARY DRAINAGE
OF SCUPPER SYSTEMS REQUIRED IN ACCORDANCE WITH THIS CODE SHALL NOT BE REMOVED
UNLESS THEY ARE REPLACED BY SECONDARY DRAINS OF SCUPPERS DESIGNED AND
INSTALLED IN ACCORDANCE WITH SECTION 1502 OF THE INTERNATIONAL BUILDING CODE.
SECTION 705.2 ROOF REPLACEMENT:
ROOF REPLACEMENT SHALL INCLUDE THE REMOVAL OF ALL EXISTING LAYERS OF ROOF COVERINGS
DOWN TO THE ROOF DECK.
EXCEPTION: WHERE THE EXISTING ROOF ASSEMBLY INCLUDES AN ICE BARRIER MEMBRANE THAT IS ADHERED TO THE ROOF DECK, THE EXISTING ICE BARRIER MEMBRANE SHALL BE PERMITTED TO REMAIN IN PLACE AND COVERED WITH AN ADDITIONAL LAYER OF ICE BARRIER MEMBRANE IN ACCORDANCE WITH
SECTION 1507 OF THE INTERNATIONAL BUILDING CODE.
SECTION 705.5 FLASHINGS.
FLASHINGS SHALL BE RECONSTRUCTED IN ACCORDANCE WITH APPROVED MANUFACTURER'S
INSTALLATION INSTRUCTIONS. METAL FLASHING TO WHICH BITUMINOUS MATERIALS ARE TO BE
ADHERED SHALL BE PRIMED PRIOR TO INSTALLATION.
SECTION 706.2 ADDITION OR REPLACEMENT OF ROOFING OR REPLACEMENT OF EQUIPMENT.
ANY EXISTING GRAVITY LOAD-CARRYING STRUCTURAL ELEMENT FOR WHICH AN ALTERATION CAUSES AN INCREASE IN DESIGN DEAD, LIVE OR SNOW LOAD, INCLUDING SNOW DRIFT EFFECTS, OF MORE
THAN 5 PERCENT SHALL BE REPLACED OR ALTERED AS NEEDED TO CARRY THE GRAVITY LOADS
REQUIRED BY THE INTERNATIONAL BUILDING CODE FOR NEW STRUCTURES. THE INCREASE IN
GRAVITY LOADS SHALL ACCOUNT FOR THE CUMULATIVE EFFECTS OF THE ADDITIONS SINCE ORIGINAL
CONSTRUCTION.
EXCEPTIONS:
2. BUILDINGS IN WHICH THE INCREASED DEAD LOAD IS DUE ENTIRELY TO THE ADDITION OF A
SECOND LAYER OF ROOF COVERING WEIGHING 3 POUNDS PER SQUARE FOOT OR LESS OVER AN
EXISTING LAYER OF ROOF COVERING. INSULATION SHALL NOT BE ADDED SUCH THAT IT
INCREASE THE THERMAL FACTOR Ct IN ACCORDANCE WITH ASCE 7-16 TABLE 7.3-2 WITHOUT
CHECKING CAPACITY OF EXISTING STRUCTURE.
3. STRUCTURAL ELEMENTS WHOSE DEMAND CAPACITY RATIO IS NOT INCREASED BY MORE THAN
5%.
SECTION 706.3.2 ROOF DIAPHRAGMS RESISTING WIND UPLIFT LOADS IN HIGH-WIND REGIONS.
FOR RISK CATEGORY III AND IV BUILDINGS WHERE ROOFING MATERIALS ARE REMOVED FROM MORE THAN 50 PERCENT OF THE ROOF DIAPHRAGM OR SECTION OF BUILDING WITHIN A 5-YEAR PERIOD LOCATED WHERE THE ULTIMATE DESIGN WIND SPEED, Vult, DETERMINED IN ACCORDANCE WITH TABLE
1604.11 OF 780 CMR, IS GREATER THAN 130 MPH, CONNECTIONS OF THE ROOF DIAPHRAGM TO THE ROOF FRAMING MEMBERS, INCLUDING THE BUILDING PERIMETER SHALL BE EVALUATED FOR WIND UPLIFT LOADS SPECIFIED IN THE INTERNATIONAL BUILDING CODE. IF THE CONNECTIONS IN THEIR CURRENT CONDITION ARE NOT CAPABLE OF RESISTING 75 PERCENT OF THOSE WIND UPLIFT LOADS, THEY SHALL BE REPLACED OR STRENGTHENED IN ACCORDANCE WITH THE LOADS SPECIFIED IN THE
INTERNATIONAL BUILDING CODE.
EXCEPTION: BUILDING THAT HAVE BEEN DEMONSTRATED TO COMPLY WITH THE WIND LOAD
PROVISIONS IN 780 CMR 5TH EDITION OR LATER EDITIONS.
SECTION 708.1 ENERGY CONSERVATION.
LEVEL 1 ALTERATIONS TO EXISTING BUILDINGS OF STRUCTURES DO NOT REQUIRE THE ENTIRE BUILDING OR STRUCTURE TO COMPLY WITH THE ENERGY REQUIREMENTS OF THE INTERNATIONAL
ENERGY CONSERVATION CODE OR INTERNATIONAL RESIDENTIAL CODE. THE ALTERATION SHALL
CONFORM TO THE ENERGY REQUIREMENTS OF THE INTERNATIONAL ENERGY CONSERVATION CODE
OF INTERNATIONAL RESIDENTIAL CODE AS THEY RELATE TO NEW CONSTRUCTION ONLY.
SECTION 501.2 COMPLIANCE.
ADDITIONS, ALTERATIONS, REPAIRS, AND CHANGES OF OCCUPANCY TO, OR RELOCATION OF,
EXISTING BUILDINGS AND STRUCTURES SHALL COMPLY WITH SECTION C502, C503, C504 AND C505 OF THIS CODE, AND APPLICABLE, AND WITH THE PROVISIONS FOR ALTERATIONS, REPAIRS, ADDITIONS
AND CHANGES OF OCCUPANCY OR RELOCATION, RESPECTIVELY, IN THE INTERNATIONAL BUILDING
CODE, INTERNATIONAL EXISTING BUILDING CODE, INTERNATIONAL FUEL GAS CODE, INTERNATIONAL
MECHANICAL CODE, INTERNATIONAL PLUMBING CODE, INTERNATIONAL PROPERTY MAINTENANCE
CODE, INTERNATIONAL PRIVATE SEWAGE DISPOSAL CODE AND NFPA 70. CHANGES WHERE
UNCONDITIONED SPACE IS CHANGED TO CONDITIONED SPACE SHALL COMPLY WITH SECTION C502.
EXCEPTION: ADDITIONS, ALTERATIONS, REPAIRS OR CHANGES OF OCCUPANCY COMPLYING WITH
ANSI/ASHRA/IESNA 90.1.
SECTION C501.4 NEW AND REPLACEMENT MATERIALS.
EXCEPT AS OTHERWISE REQUIRED OR PERMITTED BY THIS CODE, MATERIALS PERMITTED BY THE APPLICABLE CODE FOR NEW CONSTRUCTION SHALL BE USED. LIKE MATERIALS SHALL BE PERMITTED
FOR REPAIRS, PROVIDED THAT HAZARDS TO LIFE, HEALTH OR PROPERTY ARE NOT CREATED.
HAZARDOUS MATERIALS SHALL NOT BE USED WHERE THE CODE FOR NEW CONSTRUCTION WOULD
NOT ALLOW USE OF THESE MATERIALS IN BUILDINGS OF SIMILAR OCCUPANCY, PURPOSE AND
LOCATION.
SECTION C503.2.1 ROOF REPLACEMENT.
ROOF REPLACEMENTS SHALL COMPLY WITH SECTION C402.1.3, C402.1.4, C402.1.5 OR C407 WHERE THE
EXISTING ROOF ASSEMBLY IS PART OF THE BUILDING THERMAL ENVELOPE AND CONTAINS
INSULATION ENTIRELY ABOVE THE ROOF DECK. IN NO CASE SHALL THE R-VALUE OF THE ROOF INSULATION BE REDUCE OR THE U-FACTOR OF THE ROOF ASSEMBLY BE INCREASE AS PART OF THE
ROOF REPLACEMENT.
SECTION C504 REPAIRS.
SECTION C504.1 GENERAL.
BUILDINGS AND STRUCTURES, AND PARTS THEREOF, SHALL BE REPAIRED IN COMPLIANCE WITH SECTION C501.3 AND THIS SECTION. WORK ON NON DAMAGED COMPONENTS THAT IS NECESSARY FOR
THE REQUIRED REPAIR OF DAMAGED COMPONENTS SHALL BE CONSIDERED TO BE PART OF THE
REPAIR AND SHALL NOT BE SUBJECT TO THE REQUIREMENTS FOR ALTERATIONS IN THIS CHAPTER.
ROUTINE MAINTENANCE REQUIRED BY SECTION C501.3, ORDINARY REPAIRS EXEMPT FROM PERMIT
AND ABATEMENT OF WEAR DUE TO NORMAL SERVICE CONDITIONS SHALL NOT BE SUBJECT TO THE
REQUIREMENTS FOR REPAIRS IN THIS SECTION.
WHERE A BUILDING WAS CONSTRUCTED TO COMPLY WITH ANSI/ASHRAE/IESNA 90.1, REPAIRS SHALL COMPLY WITH THE STANDARD AND NEED NOT COMPLY WITH SECTIONS C402, C403, C404 AND C405.
SECTION C504.2 APPLICATION.
FOR THE PURPOSES OF THIS CODE, THE FOLLOWING SHALL BE CONSIDERED TO BE REPAIRS:
2. ROOF REPAIRS.
3. AIR BARRIERS SHALL NOT BE REQUIRED FOR ROOF REPAIRS WHERE THE REPAIRS TO THE
BUILDING DO NOT INCLUDE ALTERATIONS, RENOVATIONS OR REPAIR TO THE REMAINDER OF
THE BUILDING ENVELOPE.
CHAPTER 13 ENERGY EFFICIENCY
TABLE C301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY, AND TERRITORY.
MASSACHUSETTS 5A(ALL)
CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY.
TABLE 402.1.4 BUILDING ENVELOPE REQUIREMENTS - ROOF ASSEMBLIES MINIMUM U-VALUE: U-.032 ci
L
O N
G W
A T
E R
D R
N O
R W
E L
L
M A
H
A R
V A
R D
R
C E
S T
E R
M
A
.8
.9 h a b e e b a rc h .c o m
A
B
PROJECT NO:
DATE:
DRAWN BY:
CHECKED BY:
P L O
T T
E D
O N
B
C
A
T h is B o rd e r is in te n d e d f o r a x s h e ri n te d s h e e t s iz e d iff e rs re fe r to g ra p h ic b a r s c a le s o n ly
C o p y ri g h t H a b e e b
A s s o c ia te s A rc h it e c ts
D
As indicated
/1
/2
:4 :2
A
M
G-010
BUILDING CODE
SUMMARY AND SITE
PLAN
2505.01
11/18/26
E.G.
JGM/JP/TP
L
IB
E
R T
Y H
IL
L
A V
E N
U E
S A
L E
M
B A
T E
S E
L E
M E
N T
A R
Y S
C H
O O
L
M S
B A
A C
C E
L E
R A
T E
D R
E P
A
IR
P R
O G
R A
M R
O O
F R
E P
L A
C E
M E
N T
SCALE: NOT TO SCALE
1 ARCHITECTURAL / LOGISTICS SITE PLAN
NOTE:
1. GC SHALL BE RESPONSIBLE FOR THE REPAIR AND REPLACEMENT OF ALL EXISTING
SITE AMENITIES, LAWN, CURBS, SIDEWALKS, LANDSCAPING VEGETATION, ETC., THAT
ARE DAMAGED DURING CONSTRUCTION.
2. GC SHALL NOTIFY THE TOWN OF SALEM AT LEAST 48 HOURS PRIOR TO THE
DEMOLITION AND CONSTRUCTION OF ANY ASPHALT PAVING.
REVISIONS
Δ MM-DD-YYYY DESCRIPTION
CONTRACTOR PARKING
CONTRACTOR LAY DOWN AREA, SITE
TRAILER, SANITARY FACILITES
AG
AA
A2 A3 A4 A4.7 A6 A6.4 A7
AF
AE
AD
AC
AB
AA.5
CF
CE
CD
CA
C01 C02 C03
CZ
C1
C2
C4
C5
CURVED ROOF
SLOPED WALL
BENEATH OVERHANG
EXISTING GLAZED
AWNINGS BELOW
TO REMAIN.
CURVED ROOF
MAIN ENTRANCE
CANOPY BELOW
50 SF
CANOPY BELOW
200 SF
ENTRANCE CANOPY BELOW
100 SF
E.J.
CURVED ENTRANCE
CANOPY BELOW
100 SF
E.J. D1
D1
D1
D1
D2
D2
D1
D1
D3
D1
D2
D2
D2
HP
SG
SG
HP
LP
LP
HP
LP
HP
HP
REMOVE EXISTING
LIGHTNING PROTECTION
SYSTEM
LP,
TYPICAL
REMOVE EXISTING LIGHTNING
PROTECTION SYSTEM
EL. 122'-3"±
ROOF
EL. 123'-09"±
ROOF
EL. 122'-3"±
ROOF
EL. 126'-5"±
ROOF
EL. 134'-6"±
ROOF HP
EL. 130'-0"±
ROOF HP
EL. 128'-0"±
ROOF
EL. 113'-0"±
LOW ROOF
EL. 110'-0"±
LOW ROOF
EL. 114'-4"±
LOW ROOF
EL. 111'-0"±
LOW ROOF
EL. 120'-6"±
ROOF LP
EFEF VP
VP
RD
RH
RD
EF
VP
EF
RD
EF
RD
RD EF
VP
VP
RD
EF
VP
VP
EF
EF
EF
VP
VP
D1
RD RDRTU
RTU
RTU
RTU
RTU
VP
RD RD
VP
RD
RD
RD
RD
ACC
BOILER FLUE
DOMESTIC HOT
WATER FLUE
RTU
RTU
RD
RD
RD
RD
E.J.
ERL
G
G
RTU
VP
RD
VP
RD
RD
RD
RD
CH
RTU
RD
RD
RD
RD
RTU
VP
EF
EF
VP
RH
FP
EF
RD
EF
CU
CU
HV
RD
LP,
TYPICAL
D
RTU
G
D4
D4
NOTE: 1/2" HIGH DENSITY
PROTECTION BOARD OVER THE
METAL DECK TO BE REMOVED - GC TO
V.I.F. THE EXTEND OF THE AREA.
NOTE: OLD EPDM ROOF WITH 2" INSULATIONS
AND TAPERED INSULATION UNDER "D1" ROOF
SYSTEM TO BE REMOVED - GC TO V.I.F. THE
EXTEND OF THE AREA.
NOTE: GRAVEL OF OLD BALLASTED
ROOF OVER THE METAL DECK TO BE
REMOVED IN ITS ENTIRETY - GC TO
V.I.F. THE EXTEND OF THE AREA.
AD-511
AD-511
AD-511
AD-511
AD-511
AD-512
AD-511
AD-511
AD-511
AD-511
AD-511
AD-511
AD-511
AD-511
AD-511
AD-511
AD-511
AD-511
SIM
AD-511
SIM
AD-512
AD-512
AD-512
AD-512
TYP
AD-512
TYP
AD-512
TYP
AD-512
TYP
AD-512
AD-512
AD-512
TYP
AD-512
TYP
AD-512
TYP
AD-512
AD-512
AD-512
AD-512
AD-512
TYP
AD-512
TYP
AD-512
TYP
AD-512
TYP
AD-512
AD-512
TYP
AD-512
TYP
AD-512
TYP
AD-512
TYP
AD-512
TYP
AD-512
TYP
AD-512
TYP
AD-512
TYP
AD-512
BRICK CHIMNEY
PENTHOUSE ROOF
200 SF
AD-512
AD-512
AD-512
AD-512
AD-512
AD-512
AD-512
AD-511
AD-512
AD-512
TYP
3A D
-130
AD-512
TYP
AD-511
AD-511
SIM.
AD-511
AD-511
SIM.
AD-512
AD-512
AD-511
SIM.
AD-512
AD-511
AD-511
AD-511
AD-513
AD-513
DEMOLISH
GUTTER AND
DOWNSPOUT
DEMOLISH
GUTTER AND
DOWNSPOUT
DEMOLISH
GUTTER AND
DOWNSPOUT
G
G
G
G
G
NOTE: DEMOLISH 'CURB' (MAX. 1FT)
AT THE EDGE OF THE ROOF TO
ACCOMMODATE FUTURE SCUPPER
ESP
ESP
ESP ESP
CU
EXISTING
ROOF CURB
TO REMAIN
8,400 SF
2,300 SF
D1
4,100 SF12,000 SF
1,500 SF
4,000 SF
5,500 SF
400 SF
800 SF
4,200 SF
AD-513
AD-513
SIM.
AD-513
SIM.
AD-513
AD-513
V
MI
VMI
V
MI
V M
I V
M I
V M
I V
M I
V M
I V
M I
V M
I
122' - 3"
EXISTING EXHAUST FAN UNIT
- DISCONNECT AND REMOVE FLASHING
EXISTING ROOF TOP UNIT
- REMOVE FLASHING
EXISTING ANTENNA EQUIPMENT STAND
ON SLEEPERS.
- REMOVED AND SALVAGE
EXISTING ROOF HATCH
- TO BE REMOVE
EXISTING CONDUIT PENETRATION
- REMOVE FLASHING
EXISTING CONDENSING UNIT
- DISCONNECT AND REMOVE FLASHING
AC UNIT
- DISCONNECT, REMOVE AND SALVAGE
EXISTING ROOF PLAN LEGEND
EXISTING VENT PIPE TO REMAIN
- REMOVE FLASHING
VP
SLOPE INDICATOR
ELEVATION MARKER
- RELATIVE TO FINISH GRADE
ELEVATION MARKER
- INDICATES HIGH POINT, LOW POINT
EXISTING ROOF DRAIN STRAINER
- TO BE REMOVED
ROOF SYSTEM TYPE INDICATOR
EXISTING ROOF LADDER TO REMAIN
- REFURBISH REPAINT
EXISTING WALKWAY PAD
- TO BE REMOVED
RH
HP LP
LOW HIGH
X'-XX"±
ELEVATION
CP
ACC
EF
RD
ERL
CU
RTU
EXISTING GUTTER AND DOWNSPOUT
- TO BE REMOVED G
EXISTING REFRIGERATION
RECIPROCATING ON STEEL DUNNAGE
LIQUID CHILLER TO REMAIN.
- REMOVE FLASHING
CH
FP
EXISTING FALL PROTECTION
- REMOVE IN ITS ENTIRETY
EXISTING AIR VENTILATION UNIT
- DISCONNECT AND REMOVE FLASHING
HV
EXISTING LIGHTING PROTECTION SYSTEM
- TO BE REMOVED LP
EXISTING SNOW GUARD
- REMOVED AND SALVAGE
SG D
EXISTING DOOR AND FRAME
- TO BE REMOVED
AREA OF WORK TO BE PERFORMED:
- SEE EXISTING ROOF TYPE SCHEDULE FOR ROOFING MATERIAL TO BE REMOVED.
EXISTING ROOF SYSTEM TYPE LEGEND
EXISTING ROOF SYSTEM TYPE D1 TO BE REMOVED:
- SEE EXISTING ROOF SYSTEM TYPE SCHEDULE BELOW
EXISTING ROOF SYSTEM TYPE D2 TO BE REMOVED:
- SEE EXISTING ROOF SYSTEM TYPE SCHEDULE BELOW
EXISTING ROOF SYSTEM TYPE D3 TO BE REMOVED:
- SEE EXISTING ROOF SYSTEM TYPE SCHEDULE BELOW
EXISTING ROOF SYSTEM TYPE D4 TO BE REMOVED:
- SEE EXISTING ROOF SYSTEM TYPE SCHEDULE BELOW
D1
D2
D3
D4
EXISTING ROOF SYSTEM TYPE SCHEDULE
EXISTING VERTICAL MEMBRANE INSERT
- TO BE REMOVED, LINEAR FEET VMI
MECHANICAL SUBCONTRACTOR [231] SHALL COORDINATE THE DISCONNECTION AND RECONNECTION FOR ALL HVAC ROOF TOP EQUIPMENT REQUIRED TO BE RAISED ONTO NEW ROOF CURBS TO MEET NEW ROOF MEMBRANE WARRANTY HEIGHT REQUIREMENTS. THE DISCONNECTION AND RECONNECTION REFERS TO ALL GAS, ELECTRICAL AND DUCTWORK CURRENTLY CONNECTED TO EACH PIECE OF HVAC EQUIPMENT. HVAC EQUIPMENT REFERS TO ALL EXHAUST FANS, ROOF TOP UNITS, CONDENSERS, COMPRESSORS, AIR HANDLING UNITS OR GENERALLY ANY HVAC RELATED
EQUIPMENT THAT IS MOUNTED ON THE ROOF.
NOTE:
ESP
EXISTING SCUPPER TO BE REMOVED
SEE DETAIL 4 ON AD-513
EXISTING EPDM ROOF MEMBRANE, FULLY
ADHERED - TO BE REMOVED
1 LAYER OF 3" +/- POLYISOCYANURATE INSULATION,
MECHANICALLY FASTENED TO BE REMOVED.
EXISTING EPDM ROOF MEMBRANE, FULLY
ADHERED -TO BE REMOVED.
1 LAYER OF 3" +/- POLYISOCYANURATE
INSULATION, MECHANICALLY FASTENED TO BE
REMOVED.
EXISTING 1/8" +/- SLOPED METAL ROOF DECK TO
REMAIN.
EXISTING 1/8" +/- SLOPED CEMENTITIOUS
WOOD FIBER ROOF.
EXISTING EPDM ROOF MEMBRANE, FULLY
ADHERED -TO BE REMOVED.
1 LAYER OF 3" BASE PLUS 2.5" +/- TAPERED
POLYISOCYANURATE INSULATION,
MECHANICALLY FASTENED TO BE REMOVED.
EXISTING METAL ROOF DECK TO REMAIN.
D2 SCALE
ROOF SYSTEM TYPE - D2
SCALE: 3" = 1'-0" 2" 4"0 8"
D3 SCALE
ROOF SYSTEM TYPE - D3
SCALE: 3" = 1'-0" 2" 4"0 8"
EXISTING EPDM ROOF MEMBRANE, FULLY
ADHERED -TO BE REMOVED.
1 LAYER OF POLYISOCYANURATE INSULATION,
MECHANICALLY FASTENED TO BE REMOVED.
EXISTING 1/8" +/- SLOPED METAL ROOF DECK TO
REMAIN.
D4 SCALE
ROOF SYSTEM TYPE - D4
SCALE: 3" = 1'-0" 2" 4"0 8"
D1 SCALE
ROOF SYSTEM TYPE - D1
SCALE: 3" = 1'-0" 2" 4"0 8"
REMOVE FLASHING MEMBRANE
SET IN BONDING ADHESIVE
REMOVE CONTINUOUS
RUBBER GASKET
EXISTING METAL ROOF
DECK TO REMAIN
D1
DEMO DOOR AND FRAME
REMOVE EXISTING THRESHOLD
FLASHING IN ITS ENTIRETY
WALL BEYOND
DEMOLISH EXTERIOR DOOR,
HARDWARE AND THRESHOLD
DEMOLISH 2" WIDE HOLLOW
METAL FRAME, PAINTED
ALUMINUM
PANELS
ALUMINUM
PANELS
EXISTING ROOF MEMBRANE TO
BE REMOVED
AD-130
TYP1
AD-130
TYP
REMOVE FLASHING MEMBRANE
SET IN BONDING ADHESIVE
EXISTING METAL ROOF
DECK TO REMAIN
REMOVE CONTINUOUS
RUBBER GASKET
D1
CUT EXISTING MEMBRANE AS
SHOWN
L
O N
G W
A T
E R
D R
N O
R W
E L
L
M A
H
A R
V A
R D
R
C E
S T
E R
M
A
.8
.9 h a b e e b a rc h .c o m
A
B
PROJECT NO:
DATE:
DRAWN BY:
CHECKED BY:
P L O
T T
E D
O N
B
C
A
T h is B o rd e r is in te n d e d f o r a x s h e ri n te d s h e e t s iz e d iff e rs re fe r to g ra p h ic b a r s c a le s o n ly
C o p y ri g h t H a b e e b
A s s o c ia te s A rc h it e c ts
D
As indicated
/1
/2
:4 :2
A
M
AD-130
OVERALL ROOF PLAN
- DEMOLITION
2505.01
11/18/26
E.G.
JM
L
IB
E
R T
Y H
IL
L
A V
E N
U E
S A
L E
M
B A
T E
S E
L E
M E
N T
A R
Y S
C H
O O
L
M S
B A
A C
C E
L E
R A
T E
D R
E P
A
IR
P R
O G
R A
M R
O O
F R
E P
L A
C E
M E
N T
M S
B A
P R
O
JE
C T
0 8' 16' 32'
SCALE: 1/16" = 1'-0"
4 ROOF - OVERALL - DEMOLITION
N
0 6" 1'3"
SCALE: 3" = 1'-0"
2 DOOR THRESHOLD DETAIL - DEMOLITION
0 1' 2' 4'
SCALE: 1/2" = 1'-0"
3 EXISTING DOOR AT ROOF
0 6" 1'3"
SCALE: 3" = 1'-0"
1 DETAIL AT ALUMINUM PANEL - DEMOLITION
EXISTING BLOCKING TO REMAIN
REMOVE EXISTING
METAL GUTTER AND ALL
ASSOCIATED
FASTENERS
REMOVE EXISTING METAL FLASHING
REMOVE EXISTING ROOF MEMBRANE
REMOVE EXISTING SEALANT
AND BACKER ROD
REMOVE EXISTING BLOCKING
EXISTING METAL CLADDING
SYSTEM TO REMAIN
EXISTING SEALANT AND BACKER ROD TO REMAIN
EXISTING METAL CLADDING SYSTEM
TO REMAIN
D1
ALUMINUM CLADDING SYSTEM
TO REMAIN
BLOCKING / FURRING,
TO REMAIN
CMU BEYOND,
TO REMAIN
EDGE OF
VERTICAL
METAL BEYOND,
TO REMAIN
METAL DECK, TO
REMAIN
D1
EXISTING BLOCKING
TO REMAIN
REMOVE METAL
FASCIA
EXISTING STRUCTURE
TO REMAIN
BUILDING FELT, TO REMAIN
METAL STUD, TO REMAIN
ALUMINUM CLADDING
SYSTEM COMPONENT,
TO REMAIN
MASONRY VENEER TIES, TO REMAIN
1/2 PLYWOOD, TO REMAIN
CMU, TO REMAIN
METAL FASCIA TO BE
REMOVED
D1
BUILT UP PARAPET PLYWOOD &
TRIANGULAR CANT / BLOCKING
TO REMAIN
SEALANT BACKER
ROD TO REMAIN
D2
MOVE TO BEHIND THE ETR
SHADE LAYER
METAL STUD, TO REMAIN
EXISTING METAL CLADDING
SYSTEM TO REMAIN.
BLOCKING / FURRING, TO REMAIN
1/2 PLYWOOD, TO REMAIN
METAL DECK,
TO REMAIN
D1EXISTING BLOCKING
TO REMAIN
ALUMINUM CLADDING
SYSTEM COMPONENT,
TO REMAIN
SEALANT BACKER
ROD TO REMAIN
CMU BEYOND, TO REMAIN
EXISTING STRUCTURE
TO REMAIN
REMOVE
METAL FASCIA
D2 D4
METAL STUD,
TO REMAIN
EXISTING SUBSTRATE TO
REMAIN
METAL DECK,
TO REMAIN
D1
REMOVE METAL
FASCIA
EXISTING METAL
CLADDING SYSTEM,
TO REMAIN
EXISTING SEALANT
AND BACKER ROD TO
REMAIN
EXISTING BLOCKING
TO REMAIN
EXISTING STRUCTURE
TO REMAIN
D2
ALUMINUM CLADDING
SYSTEM, TO REMAIN
BLOCKING / FURRING,
TO REMAIN
1/2 PLYWOOD, TO REMAIN
METAL DECK,
TO REMAIN
D1
REMOVE METAL
FASCIA
ALUMINUM CLADDING
SYSTEM COMPONENT,
TO REMAIN
SEALANT BACKER
ROD TO REMAIN
EXISTING BLOCKING
TO REMAIN
EXISTING STRUCTURE
TO REMAIN
D1
SEALANT & BACKER
ROD TO REMAIN
D1
ALUMINUM CLADDING
SYSTEM COMPONENT,
TO REMAIN
D1
EXISTING WOOD CANT
TO BE REMOVED
EXISTING EXPANSION
JOINT TO REMAIN
D2
BLOCKING TO REMAIN
DEMOLISH METAL
FLASHING
DEMOLISH ROOF MEMBRANE
DEMOLISH SEALANT
BACKER ROD
DEMOLISH METAL FLASHING
DEMOLISH BLOCKING / NAILER
ALUMINUM CLADDING
SYSTEM TO REMAIN
SEALANT BACKER ROD TO REMAIN
ALUMINUM CLADDING SYSTEM TO
REMAIN
D1
REMOVE
EXISTING
PLYWOOD
SHEATHING
EXISTING THROUGH
WALL FLASHING TO
REMAIN
REMOVE EXISTING
COUNTER FLASHING
REMOVE EXISTING TERM BAR AND
ASSOCIATED SEALANTS AND FASTENERS
EXISTING WALL TO REMAIN
NOTE:
MASONRY SUBCONTRACTOR [401]
SHALL VERIFY BRICK COURSING TO
BE REMOVED WITH GC. GC SHALL
COORDINATE WITH MASONRY
SUBCONTRACTOR [401] TO
DETERMINE THE BRICK COURSING
TO BE REMOVED BASED ON THE
THICKNESS OF INSULATION AT ALL
VERTICAL WALL FLASHING
INSTALLATION LOCATIONS.
D1 D2
D1
SEALANT & BACKER
ROD TO REMAIN
EXISTING DUCT TO REMAIN
REMOVE EXISTING
MEMBRANE FLASHING
D1
REMOVE EXISTING
MEMBRANE FLASHING
EXISTING METAL
ROOF DECK TO
REMAIN
REMOVE EXISTING EXPANSION
JOINT AND FILL MATERIAL D1
L
O N
G W
A T
E R
D R
N O
R W
E L
L
M A
H
A R
V A
R D
R
C E
S T
E R
M
A
.8
.9 h a b e e b a rc h .c o m
A
B
PROJECT NO:
DATE:
DRAWN BY:
CHECKED BY:
P L O
T T
E D
O N
B
C
A
T h is B o rd e r is in te n d e d f o r a x s h e ri n te d s h e e t s iz e d iff e rs re fe r to g ra p h ic b a r s c a le s o n ly
C o p y ri g h t H a b e e b
A s s o c ia te s A rc h it e c ts
D
3" = 1'-0"
/1
/2
:4 :2
A
M
AD-511
ROOF DETAILS -
DEMOLITION
2505.01
11/18/26
E.G.
JM
L
IB
E
R T
Y H
IL
L
A V
E N
U E
S A
L E
M
B A
T E
S E
L E
M E
N T
A R
Y S
C H
O O
L
M S
B A
A C
C E
L E
R A
T E
D R
E P
A
IR
P R
O G
R A
M R
O O
F R
E P
L A
C E
M E
N T
M S
B A
P R
O
JE
C T
0 6" 1'3"
SCALE: 3" = 1'-0"
1 CURVED ROOF FASCIA - DEMO
0 6" 1'3"
SCALE: 3" = 1'-0"
3 ROOF FASCIA 02 - DEMO
0 6" 1'3"
SCALE: 3" = 1'-0"
2 ROOF FASCIA 01 - DEMO
0 6" 1'3"
SCALE: 3" = 1'-0"
4 ROOF FASCIA 03 - DEMO
0 6" 1'3"
SCALE: 3" = 1'-0"
5 ROOF FASCIA 04 - DEMO
0 6" 1'3"
SCALE: 3" = 1'-0"
6 ROOF FASCIA 05 - DEMO
0 6" 1'3"
SCALE: 3" = 1'-0"
9 ROOF @ SLOPE TRANSITION - DEMO
0 6" 1'3"
SCALE: 3" = 1'-0"
8 ROOF DETAIL AT ROOF DUCT - DEMO
0 6" 1'3"
SCALE: 3" = 1'-0"
7 ROOF @ EXPANSION JOINT - DEMO
SCALE: 3" = 1'-0"
12 FASCIA @ CURVED ROOF 02 - DEMO
0 6" 1'3"
SCALE: 3" = 1'-0"
10 CMU WALL FLASHING - DEMO
REVISIONS
Δ MM-DD-YYYY DESCRIPTION
SCALE: 3" = 1'-0"
11 TYP EXPANSION DETAIL AT CURVED ROOF - DEMO
REMOVE EXISTING
MEMBRANE FLASHING
EXISTING METAL
ROOF DECK TO
REMAIN
REMOVE EXISTING EXPANSION
JOINT AND FILL MATERIAL
D1D1
D1
REMOVE WOOD BLOCKING
EXISTING STRUCTURE
TO REMAIN
REMOVE METAL FASCIA
AND HIS FASTENER
8" M
IN
EXISTING DUCT TO REMAIN
D1
REMOVE EXISTING FLASHING MEMBRANE
SALVAGE EXISTING EXHAUST FAN FOR REINSTALLATION
EXISTING CURB BLOCKING TO REMAIN
6" NOMINAL WIDE PRESSURE TREATED
WOOD NAILERS - MECHANICALLY
FASTENED TO ROOF DECK
REMOVE EXISTING FLASHING IN ITS ENTIRETY
SALVAGE EXISTING RTU FOR
REINSTALLATION
REMOVE EXISTING METAL FLASHING
AND ASSOCIATED FASTENERS
ETR METAL DECKEXISTING CURB STRUCTURE
TO REMAIN
REMOVE EXISTING FLASHING MEMBRANE
EXISTING MECHANICAL CURB
TO REMAIN
EXISTING DUCT TO REMAIN
EXISTING BLOCKING TO REMAIN
D1 D3
REMOVE EPDM MEMBRANEREMOVE EXISTING WALKWAY
PAD IN ITS ENTIRETY
D1
ETR SPRAY FOAM SEALANT / INSULATION
EXISTING PIPE PENETRATIONS TO REMAIN
D1
ETR CEMENT BASED GROUT
REMOVE EXISTING PITCH POCKET
IN ITS ENTIRETY
REMOVE EXISTING
MEMBRANE FLASHING EXISTING BLOCKING TO REMAIN
DEMOLISH EXISTING DRAIN STRAINER AND CLAMPING RING
EXISTING CAST IRON DRAIN BOWL AND LEADER TO REMAIN, TYPICAL
REMOVE EXISTING EPDM ROOF MEMBRANE
D1
REMOVE EXISTING TAPERED INSULATION
EXISTING PIPE INSULATION TO REMAIN, CONTRACTOR IS
RESPONSIBLE TO INSTALL NEW INSULATION IF EXISTING INSULATION
IS DAMAGED DURING CONSTRUCTION
D2 D3
6"
D1
REMOVE EXISTING FLASHING
EXISTING BLOCKING TO REMAIN
SALVAGE EXISTING EQUIPMENT FOR REINSTALLATION
REMOVE EXISTING FLASHING BOOT AND
ASSOCIATED CLAMP AND SEALANTS
D1
SPRAY FOAM SEALANT / INSULATION
ETR WOOD BLOCKING
REMOVE ALUMINUM TAPE
EXISTING PIPE TO REMAIN
D2
8" M
IN
REMOVE EXISTING ROOF
HATCH IN ITS ENTIRETY
REMOVE EXISTING EPDM MEMBRANE
EXISTING ROOF DECK TO REMAIN
EXISTING BLOCKING TO REMAIN
1x WOOD FINISH TRIM, PAINTED
D1
REMOVE
EXISTING
PLYWOOD
SHEATHING
EXISTING
THROUGH
WALL
FLASHING TO
REMAIN
REMOVE EXISTING
COUNTER FLASHING
REMOVE EXISTING TERM BAR AND
ASSOCIATED SEALANTS AND FASTENERS
EXISTING WALL TO REMAIN
N E
W R
O O
F
IN
S T
A
LL
A T
IO
N
[B Y
G C
S H
A
LL
C O
O R
D
IN
A T
E R
E M
O V
A L
W
IT
H
NOTE:
MASONRY SUBCONTRACTOR [702]
SHALL VERIFY BRICK COURSING TO
BE REMOVED WITH GC. GC SHALL
COORDINATE WITH MASONRY
SUBCONTRACTOR [702] TO
DETERMINE THE BRICK COURSING
TO BE REMOVED BASED ON THE
THICKNESS OF INSULATION AT ALL
VERTICAL WALL FLASHING
INSTALLATION LOCATIONS.
D1D2
D1
V .I
.F
REMOVE EPDM MEMBRANE
EXISTING PLYWOOD
SUBSTRATE TO REMAIN
EXISTING BLOCKING
TO REMAIN
D1
REMOVE MEMBRANE FLASHING
METAL FLASHING TO REMIAN
EXISTING GLAZING SYSTEM TO REMAIN
REMOVE EXISTING PLYWOOD
SUBSTRATE
BUILDING FELT, TO
REMAIN
METAL STUD, TO REMAIN
ALUMINUM CLADDING
SYSTEM COMPONENT,
TO REMAIN
MASONRY VENEER
TIES, TO REMAIN
1/2 PLYWOOD, TO
REMAIN
CMU, TO REMAIN
METAL FASCIA TO BE
REMOVED
METAL DECK, TO REMAIN
D1
/8
" EXISTING BLOCKING TO REMAIN
SEALANT BACKER
ROD TO REMAIN
ROOF MEMBRANE
TO BE REMOVED
D2
0 6" 1'3"
SCALE: 3" = 1'-0"
12 MASONRY WALL FLASHING - DEMO
0 1' 2'
SCALE: 3" = 1'-0"
2 EXHAUST FAN CURB DETAIL - DEMO
0 1' 2'
SCALE: 1 1/2" = 1'-0"
3 MECHANICAL CURB - DEMO
0 1' 2'
SCALE: 1 1/2" = 1'-0"
9 ROOF WALKWAY PAD DETAIL - DEMO
0 6" 1'3"
SCALE: 3" = 1'-0"
10 ROOF HATCH FLASHING DETAIL - DEMO
0 6" 1'3"
SCALE: 3" = 1'-0"
1 FASCIA DETAIL - DEMO
0 6" 1'3"
SCALE: 3" = 1'-0"
4 TYP EXPANSION DETAIL - DEMO
L
O N
G W
A T
E R
D R
N O
R W
E L
L
M A
H
A R
V A
R D
R
C E
S T
E R
M
A
.8
.9 h a b e e b a rc h .c o m
A
B
PROJECT NO:
DATE:
DRAWN BY:
CHECKED BY:
P L O
T T
E D
O N
B
C
A
T h is B o rd e r is in te n d e d f o r a x s h e ri n te d s h e e t s iz e d iff e rs re fe r to g ra p h ic b a r s c a le s o n ly
C o p y ri g h t H a b e e b
A s s o c ia te s A rc h it e c ts
D
As indicated
/1
/2
:4 :2
A
M
AD-512
ROOF DETAILS -
DEMOLITION
2505.01
11/18/26
E.G.
JM
L
IB
E
R T
Y H
IL
L
A V
E N
U E
S A
L E
M
B A
T E
S E
L E
M E
N T
A R
Y S
C H
O O
L
M S
B A
A C
C E
L E
R A
T E
D R
E P
A
IR
P R
O G
R A
M R
O O
F R
E P
L A
C E
M E
N T
M S
B A
P R
O
JE
C T
0 6" 1'3"
SCALE: 3" = 1'-0"
5 PITCH POCKET FLASHING DETAIL - DEMO
0 6" 1'3"
SCALE: 3" = 1'-0"
6 DRAIN ROOF DETAIL - DEMO
0 6" 1'3"
SCALE: 3" = 1'-0"
7 WOOD SLEEPER FLASHING - DEMO
0 6" 1'3"
SCALE: 3" = 1'-0"
8 PIPE PENETRATION FLASHING DETAIL - DEMO
SCALE: 3" = 1'-0"
13 ROOF @ VERT. TRANS. - DEMO
SCALE: 3" = 1'-0"
14 ROOF @ WINDOWS - DEMO
SCALE: 3" = 1'-0"
11 ROOF FASCIA 06 V.I.F. - DEMO
D1 REMOVE MEMBRANE FLASHING
METAL FLASHING TO REMAIN
EXISTING GLAZING SYSTEM TO REMAIN
EXISTING PLYWOOD
SUBSTRATE TO REMAIN
/2
CUT LINE
D3
REMOVE WOOD BLOCKING
EXISTING STRUCTURE
TO REMAIN
REMOVE METAL FASCIA
AND HIS FASTENER
D3
EXISTING STRUCTURE
TO REMAIN
REMOVE METAL FASCIA
AND HIS FASTENER
REMOVE WOOD BLOCKING
' - 2
EXISTING BLOCKING
TO REMAIN
EXISTING STRUCTURE
TO REMAIN
D1
REMOVE SEALANT STRIP
DEMOLISH ALUMINUM
SCUPPER BOX, AS
REQUIRED
PROFILE OF ROOF BEYOND
EXISTING WALL
ASSEMBLY
D2
8" M
IN
. T
Y P
IC
A
L 4" M
IN
T Y
P
IC
A L
REMOVE STAINLESS STEEL HOSE CLAMP
1" WIDE OVER PVC BUFFER STRIP
REMOVE FLASHING MEMBRANE - ADHERE TO
SUBSTRATE AND HOT-AIR WELD
SEAMS - PROVIDE SEALANT BEHIND
TOP EDGE OF FLASHING MEMBRANE
D1
ETR FIBERGLASS BATT INSULATION
ETR HOT STACK
REMOVE STAINLESS STEEL RAIN COLLAR
WITH HIGH TEMPERATURE SEALANT
ETR METAL CURB
REMOVE STAINLESS STEEL
HOSE CLAMP 1" WIDE
L
O N
G W
A T
E R
D R
N O
R W
E L
L
M A
H
A R
V A
R D
R
C E
S T
E R
M
A
.8
.9 h a b e e b a rc h .c o m
A
B
PROJECT NO:
DATE:
DRAWN BY:
CHECKED BY:
P L O
T T
E D
O N
B
C
A
T h is B o rd e r is in te n d e d f o r a x s h e ri n te d s h e e t s iz e d iff e rs re fe r to g ra p h ic b a r s c a le s o n ly
C o p y ri g h t H a b e e b
A s s o c ia te s A rc h it e c ts
D
3" = 1'-0"
/1
/2
:4 :2
A
M
AD-513
ROOF DETAILS -
DEMOLITION
2505.01
11/18/26
E.G.
JM
L
IB
E
R T
Y H
IL
L
A V
E N
U E
S A
L E
M
B A
T E
S E
L E
M E
N T
A R
Y S
C H
O O
L
M S
B A
A C
C E
L E
R A
T E
D R
E P
A
IR
P R
O G
R A
M R
O O
F R
E P
L A
C E
M E
N T
REVISIONS
Δ MM-DD-YYYY DESCRIPTION
SCALE: 3" = 1'-0"
1 ROOF @ WINDOWS 2 - DEMO
SCALE: 3" = 1'-0"
2 FASCIA DETAIL AT BRICK WALL 02 - DEMO
SCALE: 3" = 1'-0"
3 FASCIA DETAIL AT BRICK WALL 03 - DEMO
SCALE: 3" = 1'-0"
4 SCUPPER DETAIL - DEMOLITION
5 HEATED STACK FLASHING DETAIL - DEMO
EXISTING EXHAUST FAN UNIT
- INSTALL NEW FLASHING AND REINSTALL
EXISTING ROOF TOP UNIT
- INSTALL NEW FLASHING
EXISTING ANTENNA EQUIPMENT
STAND ON SLEEPERS.
- REINSTALL TO SAME LOCATION
NEW ROOF HATCH
- INSTALL NEW ROOF HATCH AND
FLASHING
EXISTING CONDUIT PENETRATION
- INSTALL NEW FLASHING
EXISTING CONDENSING UNIT
- RECONNECT & INSTALL NEW FLASHING
EXISTING AC UNIT
- INSTALL NEW FLASHING AND REINSTALL
ROOF PLAN LEGEND
EXISTING VENT PIPE TO REMAIN
- INSTALL NEW FLASHING
VP
SLOPE INDICATOR
ELEVATION MARKER
- RELATIVE TO FINISH GRADE
ELEVATION MARKER
- INDICATES HIGH POINT, LOW POINT
NEW ROOF DRAIN STRAINER
ROOF SYSTEM TYPE INDICATOR
NEW ROOF LADDER
- TO BE INSTALLED BY ROOFER
NEW WALKWAY PAD
NEW ROOF CRICKET
- PROVIDE CRICKET ALONG HIGH SIDE
OF ROOF PENETRATIONS GREATER
THAN 30" WIDE, TYP.
HP LP
LOW HIGH
NRL
X'-XX"±
ELEVATION
CP
ACC
EF
AREA OF WORK TO BE PERFORMED: (NEW MEMBRANE COLOR TO BE WHITE)
- SEE EXISTING ROOF TYPE SCHEDULE FOR ROOFING MATERIAL TO BE REMOVED.
ROOF SYSTEM TYPE LEGEND
NEW ROOF SYSTEM TYPE R1:
- SEE EXISTING ROOF SYSTEM TYPE SCHEDULE BELOW
NEW ROOF SYSTEM TYPE R2:
- SEE EXISTING ROOF SYSTEM TYPE SCHEDULE BELOW
NEW ROOF SYSTEM TYPE R3:
- SEE EXISTING ROOF SYSTEM TYPE SCHEDULE BELOW
NEW ROOF SYSTEM TYPE R4:
- SEE EXISTING ROOF SYSTEM TYPE SCHEDULE BELOW
R1
R2
R3
D4
RD
RTU
CU
EXISTING AIR VENTILATION UNIT
- INSTALL NEW FLASHING AND REINSTALL
HV
MECHANICAL SUBCONTRACTOR [231] SHALL COORDINATE THE DISCONNECTION AND RECONNECTION FOR ALL HVAC ROOF TOP EQUIPMENT REQUIRED TO BE RAISED ONTO NEW ROOF CURBS TO MEET NEW ROOF MEMBRANE WARRANTY HEIGHT REQUIREMENTS. THE DISCONNECTION AND RECONNECTION REFERS TO ALL GAS, ELECTRICAL AND DUCTWORK CURRENTLY CONNECTED TO EACH PIECE OF HVAC EQUIPMENT. HVAC EQUIPMENT REFERS TO ALL EXHAUST FANS, ROOF TOP UNITS, CONDENSERS, COMPRESSORS, AIR HANDLING UNITS OR GENERALLY ANY HVAC RELATED EQUIPMENT THAT IS
MOUNTED ON THE ROOF.
EXISTING SNOW GUARD
- TO BE REINSTALL, SAME LOCATION
SG
LIGHTNING PROTECTION SYSTEM
- TO BE REINSTALLED
LP
EXISTING REFRIGERATION
RECIPROCATING ON STEEL DUNNAGE
LIQUID CHILLER TO REMAIN.
- INSTALL NEW FLASHING
CH
FP
INSTALL NEW BALLASTED FALL
PROTECTION
D
NEW PAINTED DOOR, DOOR FRAME,
HARDWARE AND THRESHOLD
- TO BE INSTALLED
NOTE:
(VMI) VERTICAL MEMBRANE INSTALLATION ABOVE ROOF
VMI
TOTAL QUANTITY LF.LOCATION INDICATOR WALL DESCRIPTION
FURNISH AND INSTALL NEW VERTICAL PLYWOOD SUBSTRATE AND ROOF
MEMBRANE OVER EXISTING CONSTRUCTION.260 LF. ±
ROOF GENERAL NOTES
1. ALL WORK SHALL CONFORM TO THE LATEST EDITION OF THE MASSACHUSETTS BUILDING CODE.
2. THE INFORMATION SHOWN ON THIS PLAN WAS COMPILED FROM VARIOUS SOURCES AND MAY NOT REFLECT ACTUAL CONDITIONS AT THE TIME OF CONSTRUCTION. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS IN THE
FIELD, AND MUST NOTIFY ARCHITECT OF ANY DISCREPANCIES.
3. ALL DIMENSIONS SHOWN +/- ON ROOF PLANS SHALL BE VERIFIED IN FIELD
4. ANY CONDITION NOT FOUND DETAILED SHALL BE CONSTRUCTED IN A MANNER SIMILAR TO THAT OF THE ROOF
MEMBRANE MANUFACTURERS TYPICAL DETAILS.
5. ALL MATERIALS SHOWN ON THE DRAWINGS ARE NEW UNLESS OTHERWISE NOTED.
6. ALL EQUIPMENT, PIPES, WIRES, AND STRUCTURE TO BE PROTECTED DURING CONSTRUCTION. ALL ELECTRICAL AND HVAC EQUIPMENT REQUIRING DISCONNECTION AND RECONNECTION FOR INSTALLATION OF NEW ROOF SYSTEM SHALL BE PERFORMED BY A LICENSED ELECTRICIAN, PLUMBER AND HVAC CONTRACTOR UNDER
THE ROOF REPLACEMENT CONTRACT.
7. REMOVE EXISTING EQUIPMENT, RAISE CURB AND REINSTALL EXHAUST FAN TO MAINTAIN ROOF MEMBRANE MANUFACTURER'S MINIMUM FLASHING HEIGHT REQUIREMENTS OR DIMENSION SHOWN. EQUIPMENT SHALL BE DISCONNECTED AND RECONNECTED BY LICENSED ELECTRICIANS, PLUMBERS AND HVAC CONTRACTORS UNDER
THE ROOF REPLACEMENT CONTRACT. BY [231]
8. PROVIDE TAPERED INSULATION CRICKETS ALONG HIGH SIDE OF ROOF-TOP PENETRATIONS GREATER THAN 30 INCHES WIDE. SOME CRICKETS FOR THE ROOF TOP PENETRATIONS ARE NOT SHOWN ON ROOF PLANS FOR
CLARITY; REFER TO APPLICABLE DETAILS FOR MORE INFORMATION.
9. THE GENERAL CONTRACTOR IS REQUIRED TO CLEAN ALL INTERIOR ROOMS BENEATH AREAS OF ROOF WORK PRIOR TO TURNING OVER AFFECTED ROOMS BACK TO THE OWNER. COORDINATE CONSTRUCTION SCHEDULE WITH OWNER PRIOR TO COMMENCEMENT OF WORK. BROOM SWEEP ALL FLOOR SURFACES, VACUUM AND DUST
WIDE ALL SHELVING, FURNITURE, AND EQUIPMENT.
10. PERIMETER WOOD BLOCKING ALONG ROOF EDGES SHALL BE THE SAME HEIGHT FOR THAT ROOF LEVEL. THE CONTRACTOR SHALL SET TOP OF WOOD BLOCKING BASED ON THE HIGHEST THICKNESS OF THE INSULATION, COVER BOARD, AND CRICKET INSULATION. PROVIDE FIBERBOARD TAPERED EDGE STRIPS FULLY ADHERED TO SLOPE FROM PERIMETER WOOD BLOCKING TO INSULATION HEIGHT WHERE WOOD BLOCKING IS ABOVE INSULATION HEIGHT, EXCEPT AT EDGES WITH TAPERED CRICKETS. PERIMETER FASCIA SHALL BE ALL THE SAME HEIGHT BASED ON GREATEST NECESSARY HEIGHT FOR CRICKETS. FASCIA COVERS SHALL OVERLAP MASONRY
AND METAL WALLS BELOW BY A MINIMUM OF 2 INCHES.
11. EXPANSION JOINT SHALL TAPER OFF AT THE EDGE OF THE ROOF SO THAT THE EXPANSION JOINT IS AT ROOF
LEVEL AT THE FACE OF THE BUILDING.
12. PROVIDE WALKWAY PADS AT TOP AND BOTTOM OF ALL LADDERS, AT ROOF HATCHES AND ROOF ACCESS DOORS. PROVIDE WALKWAY PADS SURROUNDING EACH RTU AND THE DIRECT PATH BETWEEN THE ROOF ACCESS
POINT AND THE EQUIPMENT. SEE ROOF PLAN.
13. THE GENERAL CONTRACTOR SHALL LOCATE ALL EXISTING ELECTRICAL CONDUITS MOUNTED TO THE UNDERSIDE OF EXISTING ROOF DECK PRIOR TO MECHANICAL ATTACHMENT OF BASE LAYER OF ROOFING AND
WOOD BLOCKING TO AVOID PENETRATION OF CONDUIT.
14. PROVIDE EXTENDED FASTENERS AT LIGHTNING PROTECTION SYSTEM ASSEMBLY AS DETAILED. COORDINATE
FINAL CONSTRUCTIONS WITH ELECTRICAL DRAWINGS [261].
15. ROOF SHALL BE PHOTOVOLTAIC READY
RH
VMI
ROOF SYSTEM TYPE SCHEDULE
TOTAL: 515 LF. ±
250 LF. ±CFI CFI
PROVIDE NEW MASONRY WORK, NEW WEEPS AND NEW
COUNTERFLASHING TO RAISE WALL MEMBRANE TERMINATION TO MEET
CURRENT…