27-24-SPS Drawings.pdf

PDF 8 MB Posted

Attached to
27-24-SPS Bates Elementary School Roof Replacement
Solicitation number
BD-27-1165-COSPS-COSPS-135508
Issued by
Massachusetts

About this file

This is a construction drawings document for the Bates Elementary School MSBA Accelerated Repair Program roof replacement project located at 53 Liberty Hill Avenue, Salem, Massachusetts 01970. The project, identified as MSBA Project #202402580003, involves the removal and replacement of roofing systems across multiple roof levels and configurations. The scope includes demolition of existing EPDM membranes, insulation, and associated components, followed by installation of new 60 mil PVC roof membranes with polyisocyanurate insulation designed to achieve a minimum U-value of 0.032. The work encompasses approximately 42,000 square feet of roofing area across four primary roof system types (R1-R4), with additional work including new gutters, downspouts, flashing, roof hatches, walkway pads, and coordination of HVAC equipment relocation to meet manufacturer warranty requirements. Construction documents were submitted on November 18, 2026, by Skanska USA Building Inc. as the project manager on behalf of Salem Public Schools.

The project requires compliance with the 2021 International Building Code and Massachusetts Building Code (CMR 780), with roof assemblies rated for Class AC fire classification minimum and wind uplift resistance to 120 mph. The existing building, originally constructed in 1969 with additions and renovations in 1999, is classified as Type IIB construction. The estimated project cost is $2,815,315.00, representing approximately 11 percent of the building's full and fair cash value of $26,614,441.49, with work including new masonry counterflashing installation, vertical membrane installations totaling 260 linear feet, and counterflashing installations totaling 515 linear feet. The project includes coordination with multiple trade subcontractors, including mechanical [231], masonry [401], and electrical [261] contractors, with specific responsibilities identified for HVAC equipment disconnection/reconnection and new flashing installations. The roof is designated as photovoltaic-ready with designated solar installation areas totaling approximately 14,000 square feet and varying reserve structural capacity allocations.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAWING LIST

GENERAL

G-001 COVER SHEET

G-002 SYMBOLS, ABBREVIATIONS & GENERAL NOTES

G-010 BUILDING CODE SUMMARY AND SITE PLAN

ARCHITECTURAL DEMOLITION

AD-130 OVERALL ROOF PLAN - DEMOLITION

AD-511 ROOF DETAILS - DEMOLITION

AD-512 ROOF DETAILS - DEMOLITION

AD-513 ROOF DETAILS - DEMOLITION

ARCHITECTURAL

A-130 OVERALL ROOF PLAN - NEW WORK

A-511 ROOF DETAILS

A-512 ROOF DETAILS

A-513 ROOF DETAILS

STRUCTURAL

S-100 ROOF STRUCTURAL CAPACITY

PLUMBING

PD-100 PLUMBING ROOF PLAN - DEMOLITION

P-200 PLUMBING ROOF PLAN - NEW WORK

MECHANICAL

MD-100 MECHANICAL ROOF PLAN - DEMOLITION

M-200 MECHANICAL ROOF PLAN - NEW WORK

ELECTRICAL

ED-100 ELECTRICAL ROOF PLAN - DEMOLITION

E-200 MECHANICAL ROOF PLAN - NEW WORK

L

O N

G W

A T

E R

D R

N O

R W

E L

L

M A

H

A R

V A

R D

S T

W

O R

C E

S T

E R

M

A

.8

.9 h a b e e b a rc h .c o m

A

R

C

H

I

E

A

B

B

SCALE:

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

P L O

T T

E D

O N

B

C

A

T h is B o rd e r is in te n d e d f o r a x s h e e t.

If p ri n te d s h e e t s iz e d iff e rs re fe r to g ra p h ic b a r s c a le s o n ly

C o p y ri g h t H a b e e b

A s s o c ia te s A rc h it e c ts

D

/1

/2

:4 :2

A

M

G-001

COVER SHEET

2505.01

11/18/26

E.G.

JM

L

IB

E

R T

Y H

IL

L

A V

E N

U E

S A

L E

M

M

B A

T E

S E

L E

M E

N T

A R

Y S

C H

O O

L

M S

B A

A C

C E

L E

R A

T E

D R

E P

A

IR

P R

O G

R A

M R

O O

F R

E P

L A

C E

M E

N T

HABEEB & ASSOCIATES ARCHITECTS

ARCHITECT

www.habeebarch.com

150 LONGWATER DRIVE

NORWELL, MA 02061

MSBA PROJECT #

HABEEB & ASSOCIATES ARCHITECTS

www.habeebarch.com

150 LONGWATER DRIVE

NORWELL, MA 02061

TEL: 781-871-9804

TEL: 781-871-9804

OWNER/AWARDING AUTHORITY (NOT TO SCALE)LOCUS PLAN

STRUCTURAL

BATES ELEMENTARY SCHOOL

MSBA ACCELERATED REPAIR PROGRAM

ROOF REPLACEMENT

53 LIBERTY HILL AVENUE

SALEM, MA 01970

NOVEMBER 18, 2026

CONSTRUCTION DOCUMENTS

SUBMISSION

SKANSKA USA BUILDING INC.SALEM PUBLIC SCHOOLS

202402580003

OWNER PROJECT MANAGER

29 HIGHLAND AVE.

SALEM, MA 01970

劕匫 劕匫

TEL: 978-740-1212

salemk12.org

101 SEAPORT BOULEVARD, SUITE 200

BOSTON, MA 02210

劕匫 劕匫

TEL: 617-512-5605

usa.skanska.com

N

PROJECT LOCATION

M S

B A

P R

O

JE

C T

M

S B

A P

R O

JE

C

T

REVISIONS

Δ MM-DD-YYYY DESCRIPTION

ALUMINUM

GLASS BRICK

(REFER TO DETAILS FOR

ACCURATE COURSING LINES)

BRICK

SHEET METAL CMU

(REFER TO DETAILS FOR

ACCURATE COURSING LINES)

SYMBOLS

MASONRY BLOCK

CRUSHED STONE / GRAVEL

EARTH - ELEVATION / DETAIL

EARTH / COMPACT FILL

GYPSUM WALLBOARD

HARDWOOD

RIGID INSULATION

ROUGH LUMBER

BATT INSULATION

CERAMIC TILE

ACOUSTICAL TILE

MATERIALS (SECTION VIEWS)

MATERIALS (ELEVATION VIEWS)

GLAZED BRICK METAL LATHE & PLASTER

METAL STUD PARTITION PLASTIC

CARPET & PAD

STEEL CERAMIC TILE

MEDIUM DENSITY FIBERBOARD PLYWOOD

CONCRETE

CONCRETE RIGID INSULATION

L

O N

G W

A T

E R

D R

N O

R W

E L

L

M A

H

A R

V A

R D

R

C E

S T

E R

M

A

.8

.9 h a b e e b a rc h .c o m

A

B

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

P L O

T T

E D

O N

B

C

A

T h is B o rd e r is in te n d e d f o r a x s h e ri n te d s h e e t s iz e d iff e rs re fe r to g ra p h ic b a r s c a le s o n ly

C o p y ri g h t H a b e e b

A s s o c ia te s A rc h it e c ts

D

1 1/2" = 1'-0"

/1

/2

:4 :2

A

M

G-002

SYMBOLS,

ABBREVIATIONS &

GENERAL NOTES

2505.01

11/18/26

E.G.

JM

L

IB

E

R T

Y H

IL

L

A V

E N

U E

S A

L E

M

B A

T E

S E

L E

M E

N T

A R

Y S

C H

O O

L

M S

B A

A C

C E

L E

R A

T E

D R

E P

A

IR

P R

O G

R A

M R

O O

F R

E P

L A

C E

M E

N T

ABBREVIATIONS

GENERAL DRAWING ANNOTATIONS

DIMENSIONING LINE

REVISION ISSUE NUMBER

ITEMS WITHIN CLOUD

HAVE BEEN REVISED

INDICATES VIEW NUMBER

(KEY ON PLANS & ELEVATIONS)

INDICATES SHEET NUMBER

INDICATES VIEW NUMBER

INDICATES SHEET NUMBER

INDICATES VIEW NUMBER

INDICATES SHEET NUMBER

DETAIL REFERENCE SHEET

DETAIL REFERENCE TYPE

(IF APPLICABLE)

DETAIL NUMBER

DENOTES ALIGNMENT OF

INDICATED SURFACESALIGN

KEYNOTE TAG

-REFER TO KEYNOTE LEGEND

INDICATES ROOM NAME

DENOTES ACCESSORY

ROOM/AREA (WHERE PRESENT)

DENOTES ROOM /AREA

NUMBER

DENOTES FLOOR / LEVEL

NUMBER

COLUMN GRID

CENTERLINES

NORTH ARROW:

MATCH LINE (FOR DIVIDED

FLOOR PLAN VIEWS)

TRUE NO

RTH

0 2' 4' 8'

SCALE:

INDICATES BUILDING DATUM -

REFER TO GENERAL NOTE #9

WALL SECTION VIEW:

INDICATES VIEW NUMBER

(KEY ON PLANS & ELEVATIONS)

INDICATES SHEET NUMBER

BUILDING SECTION VIEW:

INTERIOR ELEVATION VIEW:

EXTERIOR ELEVATION VIEW:

COLUMN GRID

DESIGNATION

LEVEL INDICATOR:

DENOTES PLAN/PROJECT

NORTH

ENLARGED PLAN/DETAIL VIEW:

ROOM TAG:

VIEW TITLE:

W/ SCALE &

GRAPHIC SCALE

##/A-110A

REFERENCE FOR VIEW

CONTINUATION

GENERAL NOTES

NAME OF LEVEL

100'-0" (###.##)

1. "N.I.C." IS NOTED ON ITEMS NOT IN THE CONTRACT. "BY OWNER" AND/OR "OTHERS" ARE NOTED ON ITEMS TO BE

PROVIDED UNDER SEPARATE CONTRACT BY THE TENANT.

2. WHERE A TYPICAL CONDITION IS DETAILED AND/OR NOTED, IT SHALL BE UNDERSTOOD THAT ALL LIKE OR SIMILAR

CONDITIONS SHALL BE THE SAME UNLESS SPECIFICALLY DETAILED OR NOTED OTHERWISE.

3. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE SHOWN ON DRAWINGS. THE CONTRACTOR SHALL REQUEST CLARIFICATION FROM THE ARCHITECT OF ANY DIMENSIONAL REQUIREMENT AS NECESSARY FOR THE PROPER EXECUTION OF ANY AFFECTED WORK PRIOR TO THE COMMENCEMENT OF SUCH

WORK.

4. THE TERM "AFFECTED WORK" AS USED IN THESE GENERAL NOTES SHALL BE DEEMED TO BE ANY REQUIREMENT OF THE CONSTRUCTION DOCUMENTS AND SHALL BE FURTHER DEEMED TO INCLUDE THE PROCUREMENT OF ANY AND ALL MATERIALS, TOOLS, LABOR, ETC., AS FURTHER DESCRIBED IN THE SPECIFICATIONS, REQUIRED FOR THE

EXECUTION OF SUCH WORK.

5. THE CONTRACTOR SHALL REPORT ANY DISCREPANCY WITHIN THE CONTRACT DOCUMENTS TO THE ARCHITECT FOR CLARIFICATION AND/OR RESOLUTION PRIOR TO THE COMMENCEMENT OF ANY AFFECTED WORK. SUCH CLARIFICATION AND/OR RESOLUTION SHALL BE PROVIDED BY THE ARCHITECT PRIOR TO THE COMMENCEMENT OF

ANY AFFECTED WORK.

6. THE CONTRACTOR SHALL VERIFY ALL EXISTING SITE, BUILDING, AND UTILITY CONDITIONS, AND SHALL REPORT ANY DISCREPANCIES BETWEEN SUCH EXISTING CONDITIONS AND THE REQUIREMENTS OF THE CONTRACT DOCUMENTS TO THE ARCHITECT FOR CLARIFICATION AND/OR RESOLUTION, PRIOR TO THE COMMENCEMENT OF ANY AFFECTED WORK. THE ARCHITECT SHALL PROVIDE SUCH CLARIFICATION AND/OR RESOLUTION PRIOR TO THE

COMMENCEMENT OF ANY AFFECTED WORK.

7. NOMINAL DIMENSIONS FOR LUMBER AND WOOD TRIM ARE NOTED IN THE FOLLOWING FORMAT: 1 x 4, 5/4 x 4, 2 x 4, ETC. ACTUAL DIMENSIONS, WHERE REQUIRED, ARE NOTED AS 1" x 2" ETC.

8. VERTICAL DATUM: ARCHITECTURAL DRAWINGS REFERENCE THE MAIN FLOOR CLOSEST TO GROUND LEVEL AS

100'-0." ALL ARCHITECTURAL SPOT ELEVATIONS AS REFERENCED BY MARKER:

ARE RELATIVE TO THIS ARCHITECTURAL DATUM. THE NUMBER IN PARENTHESIS, WHERE USED, IS INTENDED TO CONVEY THE CIVIL DATUM IN DECIMAL FEET. REFER TO CIVIL DRAWINGS FOR BENCHMARK AND ACTUAL GRADE

ELEVATIONS.

ROOF PLAN - DEMOLITION

1/4" = 1'-0"

A-501

TYP

A-201

A-301

A-310

A

1ST FLOOR

EL:100'-0" (105.00)

101A

CLASSROOM

14 A-410

1 1/8"

INDICATES CIVIL DATUM -

REFER TO GENERAL NOTE #9

FILED SUB-BID LEGEND:

[###] FILED SUB-BID CATEGORY - SPECIFICATION REFERENCE

[401] MASONRY WORK - REFER TO SPEC SECTION 04 0001

[221] PLUMBING - REFER TO SPEC SECTION 22 0001

[231] HVAC - REFER TO SPEC SECTION 23 0001

[261] ELECTRICAL - REFER TO SPEC SECTION 26 0001

NOTE:

ALL OTHER WORK NOT INCLUDED IN FILED SUB BIDDERS SCOPE SHALL BE THE RESPONSIBILITY OF

THE GENERAL CONTRACTOR

DETAIL (SECTION VIEW):?

A-501

@ AT

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN

ADJ ADJUSTABLE

AFF ABOVE FINISH FLOOR

ALUM ALUMINUM

ANCH ANCHOR

APPROX APPROXIMATE(LY)

BD BOARD

BFE BOTTOM OF FOOTING

ELEVATION

BIT BITUMINOUS

BKSP BACKSPLASH

BKT BRACKET

BLDG BUILDING

BLK BLOCK

BLKG BLOCKING

BM BEAM

BOD BOTTOM OF DECK

BSMT BASEMENT

CAB CABINET

CB CHALKBOARD OR CATCH

BASIN

CEM CEMENT

CER/CT CERAMIC/ CERAMIC TILE

CG CORNER GUARD

CHP CONCRETE HOUSEKEEPING

PAD

CI CONTINUOUS INSULATION

CIP CAST IN PLACE

CJ CONTROL JOINT

CL CENTERLINE

CLG CEILING

CLKG CAULKING

CLOS CLOSET

CLR CLEAR(ANCE)

CMU CONCRETE MASONRY UNIT

CO CLEAR OPENING

COL COLUMN

CONC CONCRETE (PORTLAND

CEMENT)

COND CONDITION

CONST CONSTRUCTION

CONT CONTINUOUS

CONTR CONTRACTOR

CORR CORRIDOR

CR COLD ROLLED

CTOP COUNTERTOP

CU CUBIC, COPPER

CUH CABINET UNIT HEATER

" DITTO (REPEAT)

DA DOUBLE ACTING

DAFS DIRECT APPLIED FINISH

SYSTEM

DEMO DEMOLISH, DEMOLITION

DF DRINKING FOUNTAIN

DIA DIAMETER

DIM DIMENSION

DN DOWN

DO DOOR OPENING

DR DOOR

DS DOWNSPOUT

DSP DISPENSER

DW DISHWASHER

DWG(S) DRAWING(S)

EA EACH

ED EDUCATION

EDSP END SPLASH

EF EXHAUST FAN

EIFS EXTERIOR INSULATED FINISH

SYSTEM

EJ EXPANSION JOINT

EL ELEVATION (GRADE)

ELEC ELECTRIC(AL)

ELEV ELEVATION (FACADE)

EOD EDGE OF DECK

EP ELECTRIC PANEL

EPDM ETHYLENE PROPYLENE DIENE

MONOMER

EQ EQUAL

EQP,

EQUIP

EQUIPMENT

ES EACH SIDE

ETR EXISTING TO REMAIN

EXIST EXISTING

EXP EXPOSED

EXT EXTERIOR

EXTIN EXTINGUISHER

FB FLAT BAR

FC FIRE CODE

FCP FIBER CEMENT PANEL

FD FLOOR DRAIN

FDC FIRE DEPARTMENT

CONNECTION

FDV FIRE DEPARTMENT VALVE

FDVC FIRE DEPARTMENT VALVE

CABINET

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FACTORY FINISH

FFE FINISH FLOOR ELEVATION

FH FLAT HEAD

FHC FIRE HOSE CABINET

FIN FINISH

FL FLOOR, FLOORING

FLASH FLASHING

FLUOR FLUORESCENT

FO FRAMED OPENING

FOS FACE OF STEEL / STUD

FP FIREPROOF(ING)

FR FIRE RESISTANT

FS FIRE SHIELD

FSZ FULL SIZE

FT FEET, FOOT

FTR FIN TUBE RADIATOR

FUR FURRING

GA GAUGE

GALV GALVANIZED

GC GENERAL CONTRACTOR

GFCMU GROUND FACED CMU

GL GLASS

GMU GLAZED MASONRY UNIT

GR GRADE

GSU GLAZED STRUCTURAL UNIT

GWB GYPSUM WALL BOARD

GYP GYPSUM

HC HANDICAP(PED)

HD HEAD, HIGH DENSITY

HDR HEADER

HDWD HARDWOOD

HDWR HARDWARE

HGT HEIGHT

HM HOLLOW METAL

HORZ HORIZONTAL

HP HIGH POINT

HR HOUR

HT HEIGHT

HVAC HEATING, VENTILATION & AIR

CONDITIONING

ID INSIDE DIAMETER

IN INCH OR INCHES

IN2 SQUARE INCH

IN3 CUBIC INCHES

INCAN INCANDESCENT

INFIL INFILTRATION

INSUL INSULATION

INT INTERIOR

INV INVERT

JAN JANITOR

JB JUNCTION BOX

JST JOIST

JT JOINT

LAM LAMINATE(D)

LBS / # POUNDS

LCC LEAD COATED COPPER

LDP LAMINATED DRYWALL

PARTITION

LGMF LIGHT GAUGE METAL

FRAMING

LGTH LENGTH

LIWT LIGHT WEIGHT

LOW LIMIT OF WORK

LP LOW POINT

LTG LIGHTING

LVR LOUVER

MACH MACHINE

MAS MASONRY

MAT MATERIAL

MAX MAXIMUM

MB MARKER BOARD

MD METAL DOOR

MECH MECHANICAL

MEMBR MEMBRANE

MFGR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MMC MISC METAL CONTRACTOR

MO MASONRY OPENING

MT METAL THRESHOLD

MTD MOUNTED

MTL METAL

NAT NATURAL

NC NONCORROSIVE

NIC NOT IN CONTRACT

NO / # NUMBER

NOM NOMINAL

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER

OH OPPOSITE HAND

OPER OPERATE

OPNG OPENING

OVHD OVERHEAD

OZ OUNCES

PARTN PARTITION

PC PRECAST CONCRETE

PERIM PERIMETER

PERP PERPENDICULAR (TO)

PL PLATE

PLAS PLASTER

PLUMB PLUMBING

PLWD PLYWOOD

PNL PANEL

POL POLISHED

PR PAIR

PT PRESSURE TREATED

QT QUARRY TILE

QTY QUANTITY

R RISER

R= RADIUS

RAD ENCL RADIATOR ENCLOSURE

RB RESILIENT BASE

RD ROOF DRAIN

REF REFRIGERATOR

REINF REINFORCING

REQD REQUIRED

RESIL RESILIENT

RET RETAINING

RJ RELIEVING JOINT

RL ROOF LADDER

RM ROOM

RO ROUGH OPENING

RWL RAIN WATER LEADER

S, STR STRUCTURAL

SAM SELF ADHERED MEMBRANE

SC SCUPPER

SCHED SCHEDULE

SCN SCREEN

SD STORM DRAIN

SECT SECTION

SH SHELF, SHELVING,

SINGLE-HUNG

SHT SHEET

SIGS SILICON IMPREGNATED

GYPSUM SHEATHING

SIM SIMILAR

SIP STRUCTURAL INSULATED

PANEL

SLID SLIDING

SMV SMOKE-VENTING HATCH

SPEC SPECIFICATIONS

SPF SPECIFIED

SPK SPEAKER

SPR SPRINKLER

SQ SQUARE FEET

SS STAINLESS STEEL

ST STREET

STD STANDARD

STIFF STIFFENER

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

SUSP SUSPENDED

SY SQUARE YARD

T TREAD

T&G TONGUE & GROOVE

TB TACK BOARD

TBLE TABLE

TC TERRA COTTA

TD TRENCH DRAIN

TEL TELEPHONE

TERR TERRAZZO

TG TEMPERED GLASS

THK THICKNESS

THRESH THRESHOLD

TLT TOILET

TO TOP OF

TOB TOP OF BLOCKING

TOC TOP OF CONCRETE

TOF TOP OF FOOTING

TOM TOP OF MASONRY

TOP TOP OF PARAPET

TOR TOP OF RAIL

TOS TOP OF STEEL

TOW TOP OF WALL

TWR TOWER

TYP TYPICAL

UC UNDERCUT

UL UNDERWRITERS

LABORATORY

UNO / UON UNLESS NOTED OTHERWISE /

UNLESS OTHERWISE NOTED

UPR UPPER

UV UNIT VENTILATOR,

ULTRAVIOLET

V VOLT(AGE)

VC VINYL CLAD

VCT VINYL COMPOSITE TILE

VENT VENTILATOR

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

VMI VERTICAL MEMBRANE INSERT

VP VENT PIPE

VS VINYL SHEET

VT VINYL TILE

VWC VINYL WALL COVERING

W WIDE, WIDE FLANGE

W/ WITH

W/O, WO WITHOUT

WB WHITE BOARD (MARKER

BOARD)

WBO WORK BY OTHERS

WBOR WORK BY OWNER

WC WATER CLOSET

WD WOOD

WD WINDOW DIMENSION

WG WIRE GLASS, WALL GUARD

WH WALL-HUNG

WI WROUGHT IRON

WIND WINDOW

WO WINDOW OPENING

WP WATERPROOFING

WT WEIGHT

WWF WELDED WIRE FABRIC

WWM WELDED WIRE MESH

x INDICATES "TIMES" OR "BY"

YD YARD

Z Z STUD (STRUCTURAL SHAPE)

TYP1

ROOF SYSTEM REPLACEMENT AND HVAC REPLACEMENT - CODE ANALYSIS

REFERENCED CODES

THE BUILDING SHALL COMPLY AND/OR CONFORM TO THE FOLLOWING CONSTRUCTION

CODES, SUPPLEMENTS, STANDARDS GUIDELINES, AND ALL STANDARDS REFERENCED THEREIN:

PROJECT SUMMARY

THE PROJECT CONSISTS OF THE REMOVAL AND REPLACEMENT OF THE ROOFING SYSTEMS AS INDICATED ON PROJECT DRAWINGS AND PER THE REQUIREMENTS OF THE FOLLOWING CODES, REGULATIONS AND ALL RELEVANT

STANDARDS REFERENCED THEREIN:

1. CMR 780 MASSACHUSETTS STATE BUILDING CODE, TENTH EDITION (2021 INTERNATIONAL BUILDING CODE WITH

MASSACHUSETTS AMENDMENTS)

• CHAPTER 34 EXISTING BUILDING CODE (2021 INTERNATIONAL EXISTING BUILDING CODE WITH MASSACHUSETTS

AMENDMENTS)

• CHAPTER 13 COMMERCIAL ENERGY EFFICIENCY (2021 INTERNATIONAL ENERGY CONSERVATION ENERGY CODE

AND ASHRAE 90.1-2019 WITH MASSACHUSETTS AMENDMENTS)

• 225 CMR 23.00 MASSACHUSETTS FRONT END AMENDMENTS TO INTERNATIONAL ENERGY CONSERVATION CODE

• 2021 MASSACHUSETTS STRETCH ENERGY CODE -2023 COMMERCIAL AMENDMENTS TO IECC 2021.

2. CMR 521 MASSACHUSETTS ARCHITECTURAL ACCESS BOARD RULES AND REGULATIONS.

BUILDING USE AND OCCUPANCY

USE GROUP: EDUCATIONAL

YEAR BUILT: 1969, WITH AN ADDITION AND RENOVATION IN 1999

BUILDING CONSTRUCTION CLASSIFICATION: 2021 IBC: TYPE IIB

FIRE RATING OF ROOF ASSEMBLY: NON-RATED

CMR 780 MASSACHUSETTS STATE BUILDING CODE, TENTH EDITION ANALYSIS

CHAPTER 34: EXISTING BUILDINGS:

SECTION 101.1 SCOPE.

THE PROVISIONS OF THE INTERNATIONAL EXISTING BUILDING CODE - 2021 SHALL APPLY TO THE

REPAIR, ALTERATION, CHANGE OF OCCUPANCY, ADDITION TO AND RELOCATION OF EXISTING

BUILDINGS.

CHAPTER 6 CLASSIFICATION OF WORK

SECTION 601.1 SCOPE.

THE PROVISIONS OF THIS CHAPTER SHALL BE USED IN CONJUNCTION WITH CHAPTERS 7 THROUGH 12

AND SHALL APPLY TO THE ALTERATIONS, ADDITION AND CHANGE OF OCCUPANCY OF EXISTING

STRUCTURES, INCLUDING HISTORIC AND MOVED STRUCTURES, AS REFERENCED IN SECTION 301.3.2.

THE WORK PERFORMED ON AN EXISTING BUILDING SHALL BE CLASSIFIED IN ACCORDANCE WITH THIS

CHAPTER.

SECTION 602 ALTERATION - LEVEL 1.

SECTION 602.1 SCOPE.

LEVEL 1 ALTERATIONS INCLUDE THE REMOVAL AND REPLACEMENT OF THE COVERING OF EXISTING MATERIALS, ELEMENTS, EQUIPMENT OR FIXTURES USING NEW MATERIALS. ELEMENTS, EQUIPMENT OR

FIXTURES THAT SERVE THE SAME PURPOSE.

SECTION 602.2 APPLICATION.

LEVEL 1 ALTERATIONS SHALL COMPLY WITH THE PROVISIONS OF CHAPTER 7.

SECTION 705 REROOFING.

SECTION 705.1 GENERAL:

MATERIAL AND METHODS OF APPLICATION USED FOR RECOVERING OR REPLACING AN EXISTING ROOF COVERING SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER 15 OF THE INTERNATIONAL BUILDING

CODE.

INTERNATIONAL BUILDING CODE 2021

SECTION 1504 PERFORMANCE REQUIREMENTS:

ROOF MATERIAL PERFORMANCE AND INSTALLATION WILL BE DESIGNED AND INSTALLED IN

ACCORDANCE WITH CHAPTER 15. FOR THE LOW SLOPE ROOFS WE PROPOSE TO USE A FULLY

ADHERED SINGLE-PLY PVC MEMBRANE ROOF SYSTEM. PER SECTION 1504.8 LOW SLOPED ROOFS MUST RESIST IMPACT DAMAGE BASED ON THE RESULTS OF TEST CONDUCTED IN ACCORDANCE WITH ASTM D 3746, ASTM D 4272. ROOF COVERINGS SHOULD ALSO BE IN ACCORDANCE WITH FM4470. THE ROOFING

MANUFACTURES WILL BE REQUIRED TO MEET THE PERFORMANCE AND THE WIND UPLIFT

REQUIREMENTS OF THE CODE FOR WINDS UP TO 120 MPH.

SECTION 1505 FIRE CLASSIFICATION

TABLE 1505.1 REQUIRES A MINIMUM FIRE RESISTANCE CLASSIFICATION RATING OF AC FOR TYPE IIB

BUILDINGS.

FOR THE LOW SLOPE ROOFS WE PROPOSE TO USE A FULLY ADHERED SINGLE-PLY PVC MEMBRANE

ROOF SYSTEM WITH A CLASS AC RATING OR BETTER.

SECTION 1506 MATERIALS

SECTION 1506.2 MATERIAL SPECIFICATIONS AND PHYSICAL CHARACTERISTICS.

ROOFING COVERING MATERIALS SHALL CONFORM TO THE APPLICABLE STANDARDS LISTED IN THE

CHAPTER.

SECTION 1506.3 PRODUCT IDENTIFICATION.

ROOF-COVERING MATERIALS SHALL BE DELIVERED IN PACKAGES BEARING THE MANUFACTURER'S

IDENTIFYING MARKS AND APPROVED TESTING AGENCY LABELS REQUIRED IN ACCORDANCE WITH

SECTION 1505. BULK SHIPMENTS OF MATERIALS SHALL BE ACCOMPANIED WITH THE SAME

INFORMATION ISSUED IN THE FORM OF A CERTIFICATE OR ON A BILL OF LADING BY THE

MANUFACTURER.

SECTION 1507 REQUIREMENTS FOR COVERINGS.

ROOF COVERINGS SHALL BE APPLIED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF THIS

SECTION AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.

SECTION 1508 ROOF INSULATION

SECTION 1508.1 GENERAL.

THE USE OF ABOVE-DECK THERMAL INSULATION SHALL BE PERMITTED PROVIDED THAT SUCH

INSULATION IS COVERED WITH AN APPROVED ROOF COVERING AND PASSES THE TESTS OF NFPA 276

OR UL 1256 WHEN TESTED AS AN ASSEMBLY.

SECTION 1512.2 ROOF REPLACEMENT.

ROOF REPLACEMENT SHALL INCLUDE THE REMOVAL OF ALL EXISTING LAYERS OF ROOF ASSEMBLY

MATERIALS DOWN TO ROOF DECK.

EXCEPTION: WHERE THE EXISTING ROOF ASSEMBLY INCLUDES AN ICE BARRIER THAT IS ADHERED TO THE ROOF DECK, THE EXISTING ICE BARRIER MEMBRANE SHALL BE PERMITTED TO REMAIN IN PLACE

AND COVERED WITH AN ADDITIONAL LAYER OF ICE BARRIER MEMBRANE IN ACCORDANCE WITH

SECTION 1507.

INTERNATIONAL ENERGY CONSERVATION CODE, 2021

CHAPTER 5 [CE] EXISTING BUILDINGS.

SECTION C501.1.1 EXISTING BUILDINGS

EXCEPT AS SPECIFIED IN THIS CHAPTER, THIS CODE SHALL NOT BE USED TO REQUIRE THE REMOVAL, ALTERATION OR ABANDONMENT, NOR PREVENT THE CONTINUED USE AND MAINTENANCE OF, EXISTING BUILDINGS OR BUILDING SYSTEM LAWFULLY IN EXISTENCE AT THE TIME OF ADOPTION OF

THIS CODE.

CMR 521 MASSACHUSETTS ARCHITECTURAL ACCESS BOARD RULES AND REGULATIONS

3.00: JURISDICTION:

3.3 EXISTING BUILDINGS

ALL ADDITIONS TO, RECONSTRUCTION, REMODELING, AND ALTERATIONS OR REPAIRS OF EXISTING PUBLIC BUILDINGS OR FACILITIES, WHICH REQUIRE A BUILDING PERMIT, OR WHICH ARE SO DEFINED BY A STATE OR LOCAL INSPECTOR, SHALL BE GOVERNED BY ALL APPLICABLE SUBSECTIONS IN 521 CMR 3.00: JURISDICTION.

3.3.1: IF THE WORK BEING PERFORMED AMOUNTS TO LESS THAN 30% OF THE FULL AND FAIR CASH VALUE OF THE

BUILDING AND:

A. IF THE WORK COSTS LESS THAN $100,000, THEN ONLY THE WORK BEING PERFORMED IS REQUIRED TO

COMPLY WITH 521 CMR

OR

B. IF THE WORK COSTS $100,000 OR MORE, THEN THE WORK BEING PERFORMED IS REQUIRED TO COMPLY WITH 521 CMR. IN ADDITION, AN ACCESSIBLE PUBLIC ENTRANCE AND AN ACCESSIBLE TOILET ROOM, TELEPHONE, DRINKING FOUNTAIN (IF TOILETS, TELEPHONES AND DRINKING FOUNTAINS ARE

PROVIDED) SHALL ALSO BE PROVIDED IN COMPLIANCE WITH 521 CMR. EXCEPTION: WHETHER

PERFORMED ALONE OR IN COMBINATION WITH EACH OTHER, THE FOLLOWING TYPES OF

ALTERATIONS ARE NOT SUBJECT TO 521 CMR 3.3.1, UNLESS THE COST OF THE WORK EXCEEDS $500,000 OR UNLESS WORK IS BEING PERFORMED ON THE ENTRANCE OR TOILET. (WHEN PERFORMING EXEMPTED WORK, A MEMO STATING THE EXEMPTED WORK AND ITS COSTS MUST BE FILED WITH THE

PERMIT APPLICATION OR A SEPARATE BUILDING PERMIT MUST BE OBTAINED.)

A. CURB CUTS: THE CONSTRUCTION OF CURB CUTS SHALL COMPLY WITH 521 CMR 21.00: CURB

CUTS.

B. ALTERATION WORK WHICH IS LIMITED SOLELY TO ELECTRICAL MECHANICAL, OR PLUMBING

SYSTEMS; TO ABATEMENT OF HAZARDOUS MATERIALS; OR RETROFIT OF AUTOMATIC

SPRINKLERS AND DOES NOT INVOLVE THE ALTERATION OF ANY ELEMENTS OR SPACES

REQUIRED TO BE ACCESSIBLE UNDER 521 CMR. WHERE ELECTRICAL OUTLETS AND CONTROLS

ARE ALTERED, THEY MUST COMPLY WITH 521 CMR.

C. ROOF REPAIR OR REPLACEMENT, WINDOW REPAIR OR REPLACEMENT, REPOINTING AND

MASONRY REPAIR WORK.

D. WORK RELATING TO SEPTIC SYSTEM REPAIRS, (INCLUDING TITLE V, 310 CMR 15.00,

IMPROVEMENTS) SITE UTILITIES AND LANDSCAPING.

3.3.2: IF THE WORK PERFORMED, INCLUDING THE EXEMPTED WORK, AMOUNTS TO 30% OR MORE OF THE FULL AND FAIR CASH VALUE (SEE 521 CMR 5.00) OF THE BUILDING THE ENTIRE BUILDING IS REQUIRED TO COMPLY WITH

521 CMR.

A. WHERE THE COST OF CONSTRUCTING AN ADDITION TO A BUILDING AMOUNTS TO 30% OR MORE OF THE FULL AND FAIR CASH VALUE OF THE EXISTING BUILDING, BOTH THE ADDITION AND THE EXISTING

BUILDING MUST BE FULLY ACCESSIBLE.

5.00: DEFINITIONS:

5.1 FULL AND FAIR CASH VALUE OF THE BUILDING

THE ASSESSED VALUATION OF A BUILDING (NOT INCLUDING THE LAND) AS RECORDED IN THE ASSESSOR’S OFFICE OF THE MUNICIPALITY AT THE TIME THE BUILDING PERMIT IS ISSUED AS EQUALIZED AT 100% VALUATION. THE 100% EQUALIZED ASSESSED VALUE SHALL BE BASED UPON MASSACHUSETTS DEPARTMENT OF REVENUE’S

DETERMINATION OF THE PARTICULAR CITIES OR TOWN’S ASSESSMENT RATIO.

FOR VALUE ON YEAR 2026, THE CITY OF SALEM ASSESSMENT FOR THE BUILDING IS $25,017,558.00. THE 2024 EQUALIZED VALUATION REPORT PUBLISHED BY THE MASSACHUSETTS DIVISION OF LOCAL SERVICES INDICATES THE ASSESSMENT RATIO FOR THE NON-RESIDENTIAL PROPERTY IS 0.94, THEREFORE THE FULL AND FAIR CASH VALUE

OF THE BUILDING IS:

$25,017,558.00/.94 = $26,614,441.49

THE COST OF THE WORK IS ESTIMATED TO BE $2,815.315.00 (EXCLUDING ESTIMATED ADA UPGRADE COST) WHICH REPRESENTS 11% OF THE FULL AND FAIR CASH VALUE OF THE BUILDING. PER THE REQUIREMENTS OUTLINED IN 521 CMR 3.3.1 ADA PARKING DESIGNATION AND SIGNAGE FOR ACCESS TO THE EXISTING ADA ENTRANCE ARE BOTH EXISTING TO REMAIN AND BOTH COMPLY WITH 521 CMR. THERE IS AN EXISTING ADA TOILET ROOM THAT ALSO

COMPLIES 521 CMR.

EXCEPTIONS:

1. ROOF REPLACEMENT OR ROOF RECOVER OF EXISTING LOW-SLOPE ROOF COVERINGS SHALL

NOT BE REQUIRED TO MEET THE MINIMUM DESIGN SLOPE REQUIREMENT OF 1/4 UNIT VERTICAL PER 12 UNITS HORIZONTAL (2 PERCENT) IN SECTION 1507 OF THE INTERNATIONAL BUILDING

CODE FOR ROOFS THAT PROVIDE POSITIVE ROOF DRAINAGE.

2. RECOVERING OR REPLACING AN EXISTING ROOF COVERING SHALL NOT BE REQUIRED TO MEET

THE REQUIREMENT FOR SECONDARY (EMERGENCY OVERFLOW) DRAINS OR SCUPPERS IN

SECTION 1502 OF THE INTERNATIONAL BUILDING CODE FOR ROOFS THAT PROVIDE POSITIVE

ROOF DRAINAGE. FOR THE PURPOSES OF THIS EXCEPTION, EXISTING SECONDARY DRAINAGE

OF SCUPPER SYSTEMS REQUIRED IN ACCORDANCE WITH THIS CODE SHALL NOT BE REMOVED

UNLESS THEY ARE REPLACED BY SECONDARY DRAINS OF SCUPPERS DESIGNED AND

INSTALLED IN ACCORDANCE WITH SECTION 1502 OF THE INTERNATIONAL BUILDING CODE.

SECTION 705.2 ROOF REPLACEMENT:

ROOF REPLACEMENT SHALL INCLUDE THE REMOVAL OF ALL EXISTING LAYERS OF ROOF COVERINGS

DOWN TO THE ROOF DECK.

EXCEPTION: WHERE THE EXISTING ROOF ASSEMBLY INCLUDES AN ICE BARRIER MEMBRANE THAT IS ADHERED TO THE ROOF DECK, THE EXISTING ICE BARRIER MEMBRANE SHALL BE PERMITTED TO REMAIN IN PLACE AND COVERED WITH AN ADDITIONAL LAYER OF ICE BARRIER MEMBRANE IN ACCORDANCE WITH

SECTION 1507 OF THE INTERNATIONAL BUILDING CODE.

SECTION 705.5 FLASHINGS.

FLASHINGS SHALL BE RECONSTRUCTED IN ACCORDANCE WITH APPROVED MANUFACTURER'S

INSTALLATION INSTRUCTIONS. METAL FLASHING TO WHICH BITUMINOUS MATERIALS ARE TO BE

ADHERED SHALL BE PRIMED PRIOR TO INSTALLATION.

SECTION 706.2 ADDITION OR REPLACEMENT OF ROOFING OR REPLACEMENT OF EQUIPMENT.

ANY EXISTING GRAVITY LOAD-CARRYING STRUCTURAL ELEMENT FOR WHICH AN ALTERATION CAUSES AN INCREASE IN DESIGN DEAD, LIVE OR SNOW LOAD, INCLUDING SNOW DRIFT EFFECTS, OF MORE

THAN 5 PERCENT SHALL BE REPLACED OR ALTERED AS NEEDED TO CARRY THE GRAVITY LOADS

REQUIRED BY THE INTERNATIONAL BUILDING CODE FOR NEW STRUCTURES. THE INCREASE IN

GRAVITY LOADS SHALL ACCOUNT FOR THE CUMULATIVE EFFECTS OF THE ADDITIONS SINCE ORIGINAL

CONSTRUCTION.

EXCEPTIONS:

2. BUILDINGS IN WHICH THE INCREASED DEAD LOAD IS DUE ENTIRELY TO THE ADDITION OF A

SECOND LAYER OF ROOF COVERING WEIGHING 3 POUNDS PER SQUARE FOOT OR LESS OVER AN

EXISTING LAYER OF ROOF COVERING. INSULATION SHALL NOT BE ADDED SUCH THAT IT

INCREASE THE THERMAL FACTOR Ct IN ACCORDANCE WITH ASCE 7-16 TABLE 7.3-2 WITHOUT

CHECKING CAPACITY OF EXISTING STRUCTURE.

3. STRUCTURAL ELEMENTS WHOSE DEMAND CAPACITY RATIO IS NOT INCREASED BY MORE THAN

5%.

SECTION 706.3.2 ROOF DIAPHRAGMS RESISTING WIND UPLIFT LOADS IN HIGH-WIND REGIONS.

FOR RISK CATEGORY III AND IV BUILDINGS WHERE ROOFING MATERIALS ARE REMOVED FROM MORE THAN 50 PERCENT OF THE ROOF DIAPHRAGM OR SECTION OF BUILDING WITHIN A 5-YEAR PERIOD LOCATED WHERE THE ULTIMATE DESIGN WIND SPEED, Vult, DETERMINED IN ACCORDANCE WITH TABLE

1604.11 OF 780 CMR, IS GREATER THAN 130 MPH, CONNECTIONS OF THE ROOF DIAPHRAGM TO THE ROOF FRAMING MEMBERS, INCLUDING THE BUILDING PERIMETER SHALL BE EVALUATED FOR WIND UPLIFT LOADS SPECIFIED IN THE INTERNATIONAL BUILDING CODE. IF THE CONNECTIONS IN THEIR CURRENT CONDITION ARE NOT CAPABLE OF RESISTING 75 PERCENT OF THOSE WIND UPLIFT LOADS, THEY SHALL BE REPLACED OR STRENGTHENED IN ACCORDANCE WITH THE LOADS SPECIFIED IN THE

INTERNATIONAL BUILDING CODE.

EXCEPTION: BUILDING THAT HAVE BEEN DEMONSTRATED TO COMPLY WITH THE WIND LOAD

PROVISIONS IN 780 CMR 5TH EDITION OR LATER EDITIONS.

SECTION 708.1 ENERGY CONSERVATION.

LEVEL 1 ALTERATIONS TO EXISTING BUILDINGS OF STRUCTURES DO NOT REQUIRE THE ENTIRE BUILDING OR STRUCTURE TO COMPLY WITH THE ENERGY REQUIREMENTS OF THE INTERNATIONAL

ENERGY CONSERVATION CODE OR INTERNATIONAL RESIDENTIAL CODE. THE ALTERATION SHALL

CONFORM TO THE ENERGY REQUIREMENTS OF THE INTERNATIONAL ENERGY CONSERVATION CODE

OF INTERNATIONAL RESIDENTIAL CODE AS THEY RELATE TO NEW CONSTRUCTION ONLY.

SECTION 501.2 COMPLIANCE.

ADDITIONS, ALTERATIONS, REPAIRS, AND CHANGES OF OCCUPANCY TO, OR RELOCATION OF,

EXISTING BUILDINGS AND STRUCTURES SHALL COMPLY WITH SECTION C502, C503, C504 AND C505 OF THIS CODE, AND APPLICABLE, AND WITH THE PROVISIONS FOR ALTERATIONS, REPAIRS, ADDITIONS

AND CHANGES OF OCCUPANCY OR RELOCATION, RESPECTIVELY, IN THE INTERNATIONAL BUILDING

CODE, INTERNATIONAL EXISTING BUILDING CODE, INTERNATIONAL FUEL GAS CODE, INTERNATIONAL

MECHANICAL CODE, INTERNATIONAL PLUMBING CODE, INTERNATIONAL PROPERTY MAINTENANCE

CODE, INTERNATIONAL PRIVATE SEWAGE DISPOSAL CODE AND NFPA 70. CHANGES WHERE

UNCONDITIONED SPACE IS CHANGED TO CONDITIONED SPACE SHALL COMPLY WITH SECTION C502.

EXCEPTION: ADDITIONS, ALTERATIONS, REPAIRS OR CHANGES OF OCCUPANCY COMPLYING WITH

ANSI/ASHRA/IESNA 90.1.

SECTION C501.4 NEW AND REPLACEMENT MATERIALS.

EXCEPT AS OTHERWISE REQUIRED OR PERMITTED BY THIS CODE, MATERIALS PERMITTED BY THE APPLICABLE CODE FOR NEW CONSTRUCTION SHALL BE USED. LIKE MATERIALS SHALL BE PERMITTED

FOR REPAIRS, PROVIDED THAT HAZARDS TO LIFE, HEALTH OR PROPERTY ARE NOT CREATED.

HAZARDOUS MATERIALS SHALL NOT BE USED WHERE THE CODE FOR NEW CONSTRUCTION WOULD

NOT ALLOW USE OF THESE MATERIALS IN BUILDINGS OF SIMILAR OCCUPANCY, PURPOSE AND

LOCATION.

SECTION C503.2.1 ROOF REPLACEMENT.

ROOF REPLACEMENTS SHALL COMPLY WITH SECTION C402.1.3, C402.1.4, C402.1.5 OR C407 WHERE THE

EXISTING ROOF ASSEMBLY IS PART OF THE BUILDING THERMAL ENVELOPE AND CONTAINS

INSULATION ENTIRELY ABOVE THE ROOF DECK. IN NO CASE SHALL THE R-VALUE OF THE ROOF INSULATION BE REDUCE OR THE U-FACTOR OF THE ROOF ASSEMBLY BE INCREASE AS PART OF THE

ROOF REPLACEMENT.

SECTION C504 REPAIRS.

SECTION C504.1 GENERAL.

BUILDINGS AND STRUCTURES, AND PARTS THEREOF, SHALL BE REPAIRED IN COMPLIANCE WITH SECTION C501.3 AND THIS SECTION. WORK ON NON DAMAGED COMPONENTS THAT IS NECESSARY FOR

THE REQUIRED REPAIR OF DAMAGED COMPONENTS SHALL BE CONSIDERED TO BE PART OF THE

REPAIR AND SHALL NOT BE SUBJECT TO THE REQUIREMENTS FOR ALTERATIONS IN THIS CHAPTER.

ROUTINE MAINTENANCE REQUIRED BY SECTION C501.3, ORDINARY REPAIRS EXEMPT FROM PERMIT

AND ABATEMENT OF WEAR DUE TO NORMAL SERVICE CONDITIONS SHALL NOT BE SUBJECT TO THE

REQUIREMENTS FOR REPAIRS IN THIS SECTION.

WHERE A BUILDING WAS CONSTRUCTED TO COMPLY WITH ANSI/ASHRAE/IESNA 90.1, REPAIRS SHALL COMPLY WITH THE STANDARD AND NEED NOT COMPLY WITH SECTIONS C402, C403, C404 AND C405.

SECTION C504.2 APPLICATION.

FOR THE PURPOSES OF THIS CODE, THE FOLLOWING SHALL BE CONSIDERED TO BE REPAIRS:

2. ROOF REPAIRS.

3. AIR BARRIERS SHALL NOT BE REQUIRED FOR ROOF REPAIRS WHERE THE REPAIRS TO THE

BUILDING DO NOT INCLUDE ALTERATIONS, RENOVATIONS OR REPAIR TO THE REMAINDER OF

THE BUILDING ENVELOPE.

CHAPTER 13 ENERGY EFFICIENCY

TABLE C301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY, AND TERRITORY.

MASSACHUSETTS 5A(ALL)

CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY.

TABLE 402.1.4 BUILDING ENVELOPE REQUIREMENTS - ROOF ASSEMBLIES MINIMUM U-VALUE: U-.032 ci

L

O N

G W

A T

E R

D R

N O

R W

E L

L

M A

H

A R

V A

R D

R

C E

S T

E R

M

A

.8

.9 h a b e e b a rc h .c o m

A

B

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

P L O

T T

E D

O N

B

C

A

T h is B o rd e r is in te n d e d f o r a x s h e ri n te d s h e e t s iz e d iff e rs re fe r to g ra p h ic b a r s c a le s o n ly

C o p y ri g h t H a b e e b

A s s o c ia te s A rc h it e c ts

D

As indicated

/1

/2

:4 :2

A

M

G-010

BUILDING CODE

SUMMARY AND SITE

PLAN

2505.01

11/18/26

E.G.

JGM/JP/TP

L

IB

E

R T

Y H

IL

L

A V

E N

U E

S A

L E

M

B A

T E

S E

L E

M E

N T

A R

Y S

C H

O O

L

M S

B A

A C

C E

L E

R A

T E

D R

E P

A

IR

P R

O G

R A

M R

O O

F R

E P

L A

C E

M E

N T

SCALE: NOT TO SCALE

1 ARCHITECTURAL / LOGISTICS SITE PLAN

NOTE:

1. GC SHALL BE RESPONSIBLE FOR THE REPAIR AND REPLACEMENT OF ALL EXISTING

SITE AMENITIES, LAWN, CURBS, SIDEWALKS, LANDSCAPING VEGETATION, ETC., THAT

ARE DAMAGED DURING CONSTRUCTION.

2. GC SHALL NOTIFY THE TOWN OF SALEM AT LEAST 48 HOURS PRIOR TO THE

DEMOLITION AND CONSTRUCTION OF ANY ASPHALT PAVING.

REVISIONS

Δ MM-DD-YYYY DESCRIPTION

CONTRACTOR PARKING

CONTRACTOR LAY DOWN AREA, SITE

TRAILER, SANITARY FACILITES

AG

AA

A2 A3 A4 A4.7 A6 A6.4 A7

AF

AE

AD

AC

AB

AA.5

CF

CE

CD

CA

C01 C02 C03

CZ

C1

C2

C4

C5

CURVED ROOF

SLOPED WALL

BENEATH OVERHANG

EXISTING GLAZED

AWNINGS BELOW

TO REMAIN.

CURVED ROOF

MAIN ENTRANCE

CANOPY BELOW

50 SF

CANOPY BELOW

200 SF

ENTRANCE CANOPY BELOW

100 SF

E.J.

CURVED ENTRANCE

CANOPY BELOW

100 SF

E.J. D1

D1

D1

D1

D2

D2

D1

D1

D3

D1

D2

D2

D2

HP

SG

SG

HP

LP

LP

HP

LP

HP

HP

REMOVE EXISTING

LIGHTNING PROTECTION

SYSTEM

LP,

TYPICAL

REMOVE EXISTING LIGHTNING

PROTECTION SYSTEM

EL. 122'-3"±

ROOF

EL. 123'-09"±

ROOF

EL. 122'-3"±

ROOF

EL. 126'-5"±

ROOF

EL. 134'-6"±

ROOF HP

EL. 130'-0"±

ROOF HP

EL. 128'-0"±

ROOF

EL. 113'-0"±

LOW ROOF

EL. 110'-0"±

LOW ROOF

EL. 114'-4"±

LOW ROOF

EL. 111'-0"±

LOW ROOF

EL. 120'-6"±

ROOF LP

EFEF VP

VP

RD

RH

RD

EF

VP

EF

RD

EF

RD

RD EF

VP

VP

RD

EF

VP

VP

EF

EF

EF

VP

VP

D1

RD RDRTU

RTU

RTU

RTU

RTU

VP

RD RD

VP

RD

RD

RD

RD

ACC

BOILER FLUE

DOMESTIC HOT

WATER FLUE

RTU

RTU

RD

RD

RD

RD

E.J.

ERL

G

G

RTU

VP

RD

VP

RD

RD

RD

RD

CH

RTU

RD

RD

RD

RD

RTU

VP

EF

EF

VP

RH

FP

EF

RD

EF

CU

CU

HV

RD

LP,

TYPICAL

D

RTU

G

D4

D4

NOTE: 1/2" HIGH DENSITY

PROTECTION BOARD OVER THE

METAL DECK TO BE REMOVED - GC TO

V.I.F. THE EXTEND OF THE AREA.

NOTE: OLD EPDM ROOF WITH 2" INSULATIONS

AND TAPERED INSULATION UNDER "D1" ROOF

SYSTEM TO BE REMOVED - GC TO V.I.F. THE

EXTEND OF THE AREA.

NOTE: GRAVEL OF OLD BALLASTED

ROOF OVER THE METAL DECK TO BE

REMOVED IN ITS ENTIRETY - GC TO

V.I.F. THE EXTEND OF THE AREA.

AD-511

AD-511

AD-511

AD-511

AD-511

AD-512

AD-511

AD-511

AD-511

AD-511

AD-511

AD-511

AD-511

AD-511

AD-511

AD-511

AD-511

AD-511

SIM

AD-511

SIM

AD-512

AD-512

AD-512

AD-512

TYP

AD-512

TYP

AD-512

TYP

AD-512

TYP

AD-512

AD-512

AD-512

TYP

AD-512

TYP

AD-512

TYP

AD-512

AD-512

AD-512

AD-512

AD-512

TYP

AD-512

TYP

AD-512

TYP

AD-512

TYP

AD-512

AD-512

TYP

AD-512

TYP

AD-512

TYP

AD-512

TYP

AD-512

TYP

AD-512

TYP

AD-512

TYP

AD-512

TYP

AD-512

BRICK CHIMNEY

PENTHOUSE ROOF

200 SF

AD-512

AD-512

AD-512

AD-512

AD-512

AD-512

AD-512

AD-511

AD-512

AD-512

TYP

3A D

-130

AD-512

TYP

AD-511

AD-511

SIM.

AD-511

AD-511

SIM.

AD-512

AD-512

AD-511

SIM.

AD-512

AD-511

AD-511

AD-511

AD-513

AD-513

DEMOLISH

GUTTER AND

DOWNSPOUT

DEMOLISH

GUTTER AND

DOWNSPOUT

DEMOLISH

GUTTER AND

DOWNSPOUT

G

G

G

G

G

NOTE: DEMOLISH 'CURB' (MAX. 1FT)

AT THE EDGE OF THE ROOF TO

ACCOMMODATE FUTURE SCUPPER

ESP

ESP

ESP ESP

CU

EXISTING

ROOF CURB

TO REMAIN

8,400 SF

2,300 SF

D1

4,100 SF12,000 SF

1,500 SF

4,000 SF

5,500 SF

400 SF

800 SF

4,200 SF

AD-513

AD-513

SIM.

AD-513

SIM.

AD-513

AD-513

V

MI

VMI

V

MI

V M

I V

M I

V M

I V

M I

V M

I V

M I

V M

I

122' - 3"

EXISTING EXHAUST FAN UNIT

- DISCONNECT AND REMOVE FLASHING

EXISTING ROOF TOP UNIT

- REMOVE FLASHING

EXISTING ANTENNA EQUIPMENT STAND

ON SLEEPERS.

- REMOVED AND SALVAGE

EXISTING ROOF HATCH

- TO BE REMOVE

EXISTING CONDUIT PENETRATION

- REMOVE FLASHING

EXISTING CONDENSING UNIT

- DISCONNECT AND REMOVE FLASHING

AC UNIT

- DISCONNECT, REMOVE AND SALVAGE

EXISTING ROOF PLAN LEGEND

EXISTING VENT PIPE TO REMAIN

- REMOVE FLASHING

VP

SLOPE INDICATOR

ELEVATION MARKER

- RELATIVE TO FINISH GRADE

ELEVATION MARKER

- INDICATES HIGH POINT, LOW POINT

EXISTING ROOF DRAIN STRAINER

- TO BE REMOVED

ROOF SYSTEM TYPE INDICATOR

EXISTING ROOF LADDER TO REMAIN

- REFURBISH REPAINT

EXISTING WALKWAY PAD

- TO BE REMOVED

RH

HP LP

LOW HIGH

X'-XX"±

ELEVATION

CP

ACC

EF

RD

ERL

CU

RTU

EXISTING GUTTER AND DOWNSPOUT

- TO BE REMOVED G

EXISTING REFRIGERATION

RECIPROCATING ON STEEL DUNNAGE

LIQUID CHILLER TO REMAIN.

- REMOVE FLASHING

CH

FP

EXISTING FALL PROTECTION

- REMOVE IN ITS ENTIRETY

EXISTING AIR VENTILATION UNIT

- DISCONNECT AND REMOVE FLASHING

HV

EXISTING LIGHTING PROTECTION SYSTEM

- TO BE REMOVED LP

EXISTING SNOW GUARD

- REMOVED AND SALVAGE

SG D

EXISTING DOOR AND FRAME

- TO BE REMOVED

AREA OF WORK TO BE PERFORMED:

- SEE EXISTING ROOF TYPE SCHEDULE FOR ROOFING MATERIAL TO BE REMOVED.

EXISTING ROOF SYSTEM TYPE LEGEND

EXISTING ROOF SYSTEM TYPE D1 TO BE REMOVED:

- SEE EXISTING ROOF SYSTEM TYPE SCHEDULE BELOW

EXISTING ROOF SYSTEM TYPE D2 TO BE REMOVED:

- SEE EXISTING ROOF SYSTEM TYPE SCHEDULE BELOW

EXISTING ROOF SYSTEM TYPE D3 TO BE REMOVED:

- SEE EXISTING ROOF SYSTEM TYPE SCHEDULE BELOW

EXISTING ROOF SYSTEM TYPE D4 TO BE REMOVED:

- SEE EXISTING ROOF SYSTEM TYPE SCHEDULE BELOW

D1

D2

D3

D4

EXISTING ROOF SYSTEM TYPE SCHEDULE

EXISTING VERTICAL MEMBRANE INSERT

- TO BE REMOVED, LINEAR FEET VMI

MECHANICAL SUBCONTRACTOR [231] SHALL COORDINATE THE DISCONNECTION AND RECONNECTION FOR ALL HVAC ROOF TOP EQUIPMENT REQUIRED TO BE RAISED ONTO NEW ROOF CURBS TO MEET NEW ROOF MEMBRANE WARRANTY HEIGHT REQUIREMENTS. THE DISCONNECTION AND RECONNECTION REFERS TO ALL GAS, ELECTRICAL AND DUCTWORK CURRENTLY CONNECTED TO EACH PIECE OF HVAC EQUIPMENT. HVAC EQUIPMENT REFERS TO ALL EXHAUST FANS, ROOF TOP UNITS, CONDENSERS, COMPRESSORS, AIR HANDLING UNITS OR GENERALLY ANY HVAC RELATED

EQUIPMENT THAT IS MOUNTED ON THE ROOF.

NOTE:

ESP

EXISTING SCUPPER TO BE REMOVED

SEE DETAIL 4 ON AD-513

EXISTING EPDM ROOF MEMBRANE, FULLY

ADHERED - TO BE REMOVED

1 LAYER OF 3" +/- POLYISOCYANURATE INSULATION,

MECHANICALLY FASTENED TO BE REMOVED.

EXISTING EPDM ROOF MEMBRANE, FULLY

ADHERED -TO BE REMOVED.

1 LAYER OF 3" +/- POLYISOCYANURATE

INSULATION, MECHANICALLY FASTENED TO BE

REMOVED.

EXISTING 1/8" +/- SLOPED METAL ROOF DECK TO

REMAIN.

EXISTING 1/8" +/- SLOPED CEMENTITIOUS

WOOD FIBER ROOF.

EXISTING EPDM ROOF MEMBRANE, FULLY

ADHERED -TO BE REMOVED.

1 LAYER OF 3" BASE PLUS 2.5" +/- TAPERED

POLYISOCYANURATE INSULATION,

MECHANICALLY FASTENED TO BE REMOVED.

EXISTING METAL ROOF DECK TO REMAIN.

D2 SCALE

ROOF SYSTEM TYPE - D2

SCALE: 3" = 1'-0" 2" 4"0 8"

D3 SCALE

ROOF SYSTEM TYPE - D3

SCALE: 3" = 1'-0" 2" 4"0 8"

EXISTING EPDM ROOF MEMBRANE, FULLY

ADHERED -TO BE REMOVED.

1 LAYER OF POLYISOCYANURATE INSULATION,

MECHANICALLY FASTENED TO BE REMOVED.

EXISTING 1/8" +/- SLOPED METAL ROOF DECK TO

REMAIN.

D4 SCALE

ROOF SYSTEM TYPE - D4

SCALE: 3" = 1'-0" 2" 4"0 8"

D1 SCALE

ROOF SYSTEM TYPE - D1

SCALE: 3" = 1'-0" 2" 4"0 8"

REMOVE FLASHING MEMBRANE

SET IN BONDING ADHESIVE

REMOVE CONTINUOUS

RUBBER GASKET

EXISTING METAL ROOF

DECK TO REMAIN

D1

DEMO DOOR AND FRAME

REMOVE EXISTING THRESHOLD

FLASHING IN ITS ENTIRETY

WALL BEYOND

DEMOLISH EXTERIOR DOOR,

HARDWARE AND THRESHOLD

DEMOLISH 2" WIDE HOLLOW

METAL FRAME, PAINTED

ALUMINUM

PANELS

ALUMINUM

PANELS

EXISTING ROOF MEMBRANE TO

BE REMOVED

AD-130

TYP1

AD-130

TYP

REMOVE FLASHING MEMBRANE

SET IN BONDING ADHESIVE

EXISTING METAL ROOF

DECK TO REMAIN

REMOVE CONTINUOUS

RUBBER GASKET

D1

CUT EXISTING MEMBRANE AS

SHOWN

L

O N

G W

A T

E R

D R

N O

R W

E L

L

M A

H

A R

V A

R D

R

C E

S T

E R

M

A

.8

.9 h a b e e b a rc h .c o m

A

B

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

P L O

T T

E D

O N

B

C

A

T h is B o rd e r is in te n d e d f o r a x s h e ri n te d s h e e t s iz e d iff e rs re fe r to g ra p h ic b a r s c a le s o n ly

C o p y ri g h t H a b e e b

A s s o c ia te s A rc h it e c ts

D

As indicated

/1

/2

:4 :2

A

M

AD-130

OVERALL ROOF PLAN

- DEMOLITION

2505.01

11/18/26

E.G.

JM

L

IB

E

R T

Y H

IL

L

A V

E N

U E

S A

L E

M

B A

T E

S E

L E

M E

N T

A R

Y S

C H

O O

L

M S

B A

A C

C E

L E

R A

T E

D R

E P

A

IR

P R

O G

R A

M R

O O

F R

E P

L A

C E

M E

N T

M S

B A

P R

O

JE

C T

0 8' 16' 32'

SCALE: 1/16" = 1'-0"

4 ROOF - OVERALL - DEMOLITION

N

0 6" 1'3"

SCALE: 3" = 1'-0"

2 DOOR THRESHOLD DETAIL - DEMOLITION

0 1' 2' 4'

SCALE: 1/2" = 1'-0"

3 EXISTING DOOR AT ROOF

0 6" 1'3"

SCALE: 3" = 1'-0"

1 DETAIL AT ALUMINUM PANEL - DEMOLITION

EXISTING BLOCKING TO REMAIN

REMOVE EXISTING

METAL GUTTER AND ALL

ASSOCIATED

FASTENERS

REMOVE EXISTING METAL FLASHING

REMOVE EXISTING ROOF MEMBRANE

REMOVE EXISTING SEALANT

AND BACKER ROD

REMOVE EXISTING BLOCKING

EXISTING METAL CLADDING

SYSTEM TO REMAIN

EXISTING SEALANT AND BACKER ROD TO REMAIN

EXISTING METAL CLADDING SYSTEM

TO REMAIN

D1

ALUMINUM CLADDING SYSTEM

TO REMAIN

BLOCKING / FURRING,

TO REMAIN

CMU BEYOND,

TO REMAIN

EDGE OF

VERTICAL

METAL BEYOND,

TO REMAIN

METAL DECK, TO

REMAIN

D1

EXISTING BLOCKING

TO REMAIN

REMOVE METAL

FASCIA

EXISTING STRUCTURE

TO REMAIN

BUILDING FELT, TO REMAIN

METAL STUD, TO REMAIN

ALUMINUM CLADDING

SYSTEM COMPONENT,

TO REMAIN

MASONRY VENEER TIES, TO REMAIN

1/2 PLYWOOD, TO REMAIN

CMU, TO REMAIN

METAL FASCIA TO BE

REMOVED

D1

BUILT UP PARAPET PLYWOOD &

TRIANGULAR CANT / BLOCKING

TO REMAIN

SEALANT BACKER

ROD TO REMAIN

D2

MOVE TO BEHIND THE ETR

SHADE LAYER

METAL STUD, TO REMAIN

EXISTING METAL CLADDING

SYSTEM TO REMAIN.

BLOCKING / FURRING, TO REMAIN

1/2 PLYWOOD, TO REMAIN

METAL DECK,

TO REMAIN

D1EXISTING BLOCKING

TO REMAIN

ALUMINUM CLADDING

SYSTEM COMPONENT,

TO REMAIN

SEALANT BACKER

ROD TO REMAIN

CMU BEYOND, TO REMAIN

EXISTING STRUCTURE

TO REMAIN

REMOVE

METAL FASCIA

D2 D4

METAL STUD,

TO REMAIN

EXISTING SUBSTRATE TO

REMAIN

METAL DECK,

TO REMAIN

D1

REMOVE METAL

FASCIA

EXISTING METAL

CLADDING SYSTEM,

TO REMAIN

EXISTING SEALANT

AND BACKER ROD TO

REMAIN

EXISTING BLOCKING

TO REMAIN

EXISTING STRUCTURE

TO REMAIN

D2

ALUMINUM CLADDING

SYSTEM, TO REMAIN

BLOCKING / FURRING,

TO REMAIN

1/2 PLYWOOD, TO REMAIN

METAL DECK,

TO REMAIN

D1

REMOVE METAL

FASCIA

ALUMINUM CLADDING

SYSTEM COMPONENT,

TO REMAIN

SEALANT BACKER

ROD TO REMAIN

EXISTING BLOCKING

TO REMAIN

EXISTING STRUCTURE

TO REMAIN

D1

SEALANT & BACKER

ROD TO REMAIN

D1

ALUMINUM CLADDING

SYSTEM COMPONENT,

TO REMAIN

D1

EXISTING WOOD CANT

TO BE REMOVED

EXISTING EXPANSION

JOINT TO REMAIN

D2

BLOCKING TO REMAIN

DEMOLISH METAL

FLASHING

DEMOLISH ROOF MEMBRANE

DEMOLISH SEALANT

BACKER ROD

DEMOLISH METAL FLASHING

DEMOLISH BLOCKING / NAILER

ALUMINUM CLADDING

SYSTEM TO REMAIN

SEALANT BACKER ROD TO REMAIN

ALUMINUM CLADDING SYSTEM TO

REMAIN

D1

REMOVE

EXISTING

PLYWOOD

SHEATHING

EXISTING THROUGH

WALL FLASHING TO

REMAIN

REMOVE EXISTING

COUNTER FLASHING

REMOVE EXISTING TERM BAR AND

ASSOCIATED SEALANTS AND FASTENERS

EXISTING WALL TO REMAIN

NOTE:

MASONRY SUBCONTRACTOR [401]

SHALL VERIFY BRICK COURSING TO

BE REMOVED WITH GC. GC SHALL

COORDINATE WITH MASONRY

SUBCONTRACTOR [401] TO

DETERMINE THE BRICK COURSING

TO BE REMOVED BASED ON THE

THICKNESS OF INSULATION AT ALL

VERTICAL WALL FLASHING

INSTALLATION LOCATIONS.

D1 D2

D1

SEALANT & BACKER

ROD TO REMAIN

EXISTING DUCT TO REMAIN

REMOVE EXISTING

MEMBRANE FLASHING

D1

REMOVE EXISTING

MEMBRANE FLASHING

EXISTING METAL

ROOF DECK TO

REMAIN

REMOVE EXISTING EXPANSION

JOINT AND FILL MATERIAL D1

L

O N

G W

A T

E R

D R

N O

R W

E L

L

M A

H

A R

V A

R D

R

C E

S T

E R

M

A

.8

.9 h a b e e b a rc h .c o m

A

B

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

P L O

T T

E D

O N

B

C

A

T h is B o rd e r is in te n d e d f o r a x s h e ri n te d s h e e t s iz e d iff e rs re fe r to g ra p h ic b a r s c a le s o n ly

C o p y ri g h t H a b e e b

A s s o c ia te s A rc h it e c ts

D

3" = 1'-0"

/1

/2

:4 :2

A

M

AD-511

ROOF DETAILS -

DEMOLITION

2505.01

11/18/26

E.G.

JM

L

IB

E

R T

Y H

IL

L

A V

E N

U E

S A

L E

M

B A

T E

S E

L E

M E

N T

A R

Y S

C H

O O

L

M S

B A

A C

C E

L E

R A

T E

D R

E P

A

IR

P R

O G

R A

M R

O O

F R

E P

L A

C E

M E

N T

M S

B A

P R

O

JE

C T

0 6" 1'3"

SCALE: 3" = 1'-0"

1 CURVED ROOF FASCIA - DEMO

0 6" 1'3"

SCALE: 3" = 1'-0"

3 ROOF FASCIA 02 - DEMO

0 6" 1'3"

SCALE: 3" = 1'-0"

2 ROOF FASCIA 01 - DEMO

0 6" 1'3"

SCALE: 3" = 1'-0"

4 ROOF FASCIA 03 - DEMO

0 6" 1'3"

SCALE: 3" = 1'-0"

5 ROOF FASCIA 04 - DEMO

0 6" 1'3"

SCALE: 3" = 1'-0"

6 ROOF FASCIA 05 - DEMO

0 6" 1'3"

SCALE: 3" = 1'-0"

9 ROOF @ SLOPE TRANSITION - DEMO

0 6" 1'3"

SCALE: 3" = 1'-0"

8 ROOF DETAIL AT ROOF DUCT - DEMO

0 6" 1'3"

SCALE: 3" = 1'-0"

7 ROOF @ EXPANSION JOINT - DEMO

SCALE: 3" = 1'-0"

12 FASCIA @ CURVED ROOF 02 - DEMO

0 6" 1'3"

SCALE: 3" = 1'-0"

10 CMU WALL FLASHING - DEMO

REVISIONS

Δ MM-DD-YYYY DESCRIPTION

SCALE: 3" = 1'-0"

11 TYP EXPANSION DETAIL AT CURVED ROOF - DEMO

REMOVE EXISTING

MEMBRANE FLASHING

EXISTING METAL

ROOF DECK TO

REMAIN

REMOVE EXISTING EXPANSION

JOINT AND FILL MATERIAL

D1D1

D1

REMOVE WOOD BLOCKING

EXISTING STRUCTURE

TO REMAIN

REMOVE METAL FASCIA

AND HIS FASTENER

8" M

IN

EXISTING DUCT TO REMAIN

D1

REMOVE EXISTING FLASHING MEMBRANE

SALVAGE EXISTING EXHAUST FAN FOR REINSTALLATION

EXISTING CURB BLOCKING TO REMAIN

6" NOMINAL WIDE PRESSURE TREATED

WOOD NAILERS - MECHANICALLY

FASTENED TO ROOF DECK

REMOVE EXISTING FLASHING IN ITS ENTIRETY

SALVAGE EXISTING RTU FOR

REINSTALLATION

REMOVE EXISTING METAL FLASHING

AND ASSOCIATED FASTENERS

ETR METAL DECKEXISTING CURB STRUCTURE

TO REMAIN

REMOVE EXISTING FLASHING MEMBRANE

EXISTING MECHANICAL CURB

TO REMAIN

EXISTING DUCT TO REMAIN

EXISTING BLOCKING TO REMAIN

D1 D3

REMOVE EPDM MEMBRANEREMOVE EXISTING WALKWAY

PAD IN ITS ENTIRETY

D1

ETR SPRAY FOAM SEALANT / INSULATION

EXISTING PIPE PENETRATIONS TO REMAIN

D1

ETR CEMENT BASED GROUT

REMOVE EXISTING PITCH POCKET

IN ITS ENTIRETY

REMOVE EXISTING

MEMBRANE FLASHING EXISTING BLOCKING TO REMAIN

DEMOLISH EXISTING DRAIN STRAINER AND CLAMPING RING

EXISTING CAST IRON DRAIN BOWL AND LEADER TO REMAIN, TYPICAL

REMOVE EXISTING EPDM ROOF MEMBRANE

D1

REMOVE EXISTING TAPERED INSULATION

EXISTING PIPE INSULATION TO REMAIN, CONTRACTOR IS

RESPONSIBLE TO INSTALL NEW INSULATION IF EXISTING INSULATION

IS DAMAGED DURING CONSTRUCTION

D2 D3

6"

D1

REMOVE EXISTING FLASHING

EXISTING BLOCKING TO REMAIN

SALVAGE EXISTING EQUIPMENT FOR REINSTALLATION

REMOVE EXISTING FLASHING BOOT AND

ASSOCIATED CLAMP AND SEALANTS

D1

SPRAY FOAM SEALANT / INSULATION

ETR WOOD BLOCKING

REMOVE ALUMINUM TAPE

EXISTING PIPE TO REMAIN

D2

8" M

IN

REMOVE EXISTING ROOF

HATCH IN ITS ENTIRETY

REMOVE EXISTING EPDM MEMBRANE

EXISTING ROOF DECK TO REMAIN

EXISTING BLOCKING TO REMAIN

1x WOOD FINISH TRIM, PAINTED

D1

REMOVE

EXISTING

PLYWOOD

SHEATHING

EXISTING

THROUGH

WALL

FLASHING TO

REMAIN

REMOVE EXISTING

COUNTER FLASHING

REMOVE EXISTING TERM BAR AND

ASSOCIATED SEALANTS AND FASTENERS

EXISTING WALL TO REMAIN

N E

W R

O O

F

IN

S T

A

LL

A T

IO

N

[B Y

G C

S H

A

LL

C O

O R

D

IN

A T

E R

E M

O V

A L

W

IT

H

NOTE:

MASONRY SUBCONTRACTOR [702]

SHALL VERIFY BRICK COURSING TO

BE REMOVED WITH GC. GC SHALL

COORDINATE WITH MASONRY

SUBCONTRACTOR [702] TO

DETERMINE THE BRICK COURSING

TO BE REMOVED BASED ON THE

THICKNESS OF INSULATION AT ALL

VERTICAL WALL FLASHING

INSTALLATION LOCATIONS.

D1D2

D1

V .I

.F

REMOVE EPDM MEMBRANE

EXISTING PLYWOOD

SUBSTRATE TO REMAIN

EXISTING BLOCKING

TO REMAIN

D1

REMOVE MEMBRANE FLASHING

METAL FLASHING TO REMIAN

EXISTING GLAZING SYSTEM TO REMAIN

REMOVE EXISTING PLYWOOD

SUBSTRATE

BUILDING FELT, TO

REMAIN

METAL STUD, TO REMAIN

ALUMINUM CLADDING

SYSTEM COMPONENT,

TO REMAIN

MASONRY VENEER

TIES, TO REMAIN

1/2 PLYWOOD, TO

REMAIN

CMU, TO REMAIN

METAL FASCIA TO BE

REMOVED

METAL DECK, TO REMAIN

D1

/8

" EXISTING BLOCKING TO REMAIN

SEALANT BACKER

ROD TO REMAIN

ROOF MEMBRANE

TO BE REMOVED

D2

0 6" 1'3"

SCALE: 3" = 1'-0"

12 MASONRY WALL FLASHING - DEMO

0 1' 2'

SCALE: 3" = 1'-0"

2 EXHAUST FAN CURB DETAIL - DEMO

0 1' 2'

SCALE: 1 1/2" = 1'-0"

3 MECHANICAL CURB - DEMO

0 1' 2'

SCALE: 1 1/2" = 1'-0"

9 ROOF WALKWAY PAD DETAIL - DEMO

0 6" 1'3"

SCALE: 3" = 1'-0"

10 ROOF HATCH FLASHING DETAIL - DEMO

0 6" 1'3"

SCALE: 3" = 1'-0"

1 FASCIA DETAIL - DEMO

0 6" 1'3"

SCALE: 3" = 1'-0"

4 TYP EXPANSION DETAIL - DEMO

L

O N

G W

A T

E R

D R

N O

R W

E L

L

M A

H

A R

V A

R D

R

C E

S T

E R

M

A

.8

.9 h a b e e b a rc h .c o m

A

B

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

P L O

T T

E D

O N

B

C

A

T h is B o rd e r is in te n d e d f o r a x s h e ri n te d s h e e t s iz e d iff e rs re fe r to g ra p h ic b a r s c a le s o n ly

C o p y ri g h t H a b e e b

A s s o c ia te s A rc h it e c ts

D

As indicated

/1

/2

:4 :2

A

M

AD-512

ROOF DETAILS -

DEMOLITION

2505.01

11/18/26

E.G.

JM

L

IB

E

R T

Y H

IL

L

A V

E N

U E

S A

L E

M

B A

T E

S E

L E

M E

N T

A R

Y S

C H

O O

L

M S

B A

A C

C E

L E

R A

T E

D R

E P

A

IR

P R

O G

R A

M R

O O

F R

E P

L A

C E

M E

N T

M S

B A

P R

O

JE

C T

0 6" 1'3"

SCALE: 3" = 1'-0"

5 PITCH POCKET FLASHING DETAIL - DEMO

0 6" 1'3"

SCALE: 3" = 1'-0"

6 DRAIN ROOF DETAIL - DEMO

0 6" 1'3"

SCALE: 3" = 1'-0"

7 WOOD SLEEPER FLASHING - DEMO

0 6" 1'3"

SCALE: 3" = 1'-0"

8 PIPE PENETRATION FLASHING DETAIL - DEMO

SCALE: 3" = 1'-0"

13 ROOF @ VERT. TRANS. - DEMO

SCALE: 3" = 1'-0"

14 ROOF @ WINDOWS - DEMO

SCALE: 3" = 1'-0"

11 ROOF FASCIA 06 V.I.F. - DEMO

D1 REMOVE MEMBRANE FLASHING

METAL FLASHING TO REMAIN

EXISTING GLAZING SYSTEM TO REMAIN

EXISTING PLYWOOD

SUBSTRATE TO REMAIN

/2

CUT LINE

D3

REMOVE WOOD BLOCKING

EXISTING STRUCTURE

TO REMAIN

REMOVE METAL FASCIA

AND HIS FASTENER

D3

EXISTING STRUCTURE

TO REMAIN

REMOVE METAL FASCIA

AND HIS FASTENER

REMOVE WOOD BLOCKING

' - 2

EXISTING BLOCKING

TO REMAIN

EXISTING STRUCTURE

TO REMAIN

D1

REMOVE SEALANT STRIP

DEMOLISH ALUMINUM

SCUPPER BOX, AS

REQUIRED

PROFILE OF ROOF BEYOND

EXISTING WALL

ASSEMBLY

D2

8" M

IN

. T

Y P

IC

A

L 4" M

IN

T Y

P

IC

A L

REMOVE STAINLESS STEEL HOSE CLAMP

1" WIDE OVER PVC BUFFER STRIP

REMOVE FLASHING MEMBRANE - ADHERE TO

SUBSTRATE AND HOT-AIR WELD

SEAMS - PROVIDE SEALANT BEHIND

TOP EDGE OF FLASHING MEMBRANE

D1

ETR FIBERGLASS BATT INSULATION

ETR HOT STACK

REMOVE STAINLESS STEEL RAIN COLLAR

WITH HIGH TEMPERATURE SEALANT

ETR METAL CURB

REMOVE STAINLESS STEEL

HOSE CLAMP 1" WIDE

L

O N

G W

A T

E R

D R

N O

R W

E L

L

M A

H

A R

V A

R D

R

C E

S T

E R

M

A

.8

.9 h a b e e b a rc h .c o m

A

B

PROJECT NO:

DATE:

DRAWN BY:

CHECKED BY:

P L O

T T

E D

O N

B

C

A

T h is B o rd e r is in te n d e d f o r a x s h e ri n te d s h e e t s iz e d iff e rs re fe r to g ra p h ic b a r s c a le s o n ly

C o p y ri g h t H a b e e b

A s s o c ia te s A rc h it e c ts

D

3" = 1'-0"

/1

/2

:4 :2

A

M

AD-513

ROOF DETAILS -

DEMOLITION

2505.01

11/18/26

E.G.

JM

L

IB

E

R T

Y H

IL

L

A V

E N

U E

S A

L E

M

B A

T E

S E

L E

M E

N T

A R

Y S

C H

O O

L

M S

B A

A C

C E

L E

R A

T E

D R

E P

A

IR

P R

O G

R A

M R

O O

F R

E P

L A

C E

M E

N T

REVISIONS

Δ MM-DD-YYYY DESCRIPTION

SCALE: 3" = 1'-0"

1 ROOF @ WINDOWS 2 - DEMO

SCALE: 3" = 1'-0"

2 FASCIA DETAIL AT BRICK WALL 02 - DEMO

SCALE: 3" = 1'-0"

3 FASCIA DETAIL AT BRICK WALL 03 - DEMO

SCALE: 3" = 1'-0"

4 SCUPPER DETAIL - DEMOLITION

5 HEATED STACK FLASHING DETAIL - DEMO

EXISTING EXHAUST FAN UNIT

- INSTALL NEW FLASHING AND REINSTALL

EXISTING ROOF TOP UNIT

- INSTALL NEW FLASHING

EXISTING ANTENNA EQUIPMENT

STAND ON SLEEPERS.

- REINSTALL TO SAME LOCATION

NEW ROOF HATCH

- INSTALL NEW ROOF HATCH AND

FLASHING

EXISTING CONDUIT PENETRATION

- INSTALL NEW FLASHING

EXISTING CONDENSING UNIT

- RECONNECT & INSTALL NEW FLASHING

EXISTING AC UNIT

- INSTALL NEW FLASHING AND REINSTALL

ROOF PLAN LEGEND

EXISTING VENT PIPE TO REMAIN

- INSTALL NEW FLASHING

VP

SLOPE INDICATOR

ELEVATION MARKER

- RELATIVE TO FINISH GRADE

ELEVATION MARKER

- INDICATES HIGH POINT, LOW POINT

NEW ROOF DRAIN STRAINER

ROOF SYSTEM TYPE INDICATOR

NEW ROOF LADDER

- TO BE INSTALLED BY ROOFER

NEW WALKWAY PAD

NEW ROOF CRICKET

- PROVIDE CRICKET ALONG HIGH SIDE

OF ROOF PENETRATIONS GREATER

THAN 30" WIDE, TYP.

HP LP

LOW HIGH

NRL

X'-XX"±

ELEVATION

CP

ACC

EF

AREA OF WORK TO BE PERFORMED: (NEW MEMBRANE COLOR TO BE WHITE)

- SEE EXISTING ROOF TYPE SCHEDULE FOR ROOFING MATERIAL TO BE REMOVED.

ROOF SYSTEM TYPE LEGEND

NEW ROOF SYSTEM TYPE R1:

- SEE EXISTING ROOF SYSTEM TYPE SCHEDULE BELOW

NEW ROOF SYSTEM TYPE R2:

- SEE EXISTING ROOF SYSTEM TYPE SCHEDULE BELOW

NEW ROOF SYSTEM TYPE R3:

- SEE EXISTING ROOF SYSTEM TYPE SCHEDULE BELOW

NEW ROOF SYSTEM TYPE R4:

- SEE EXISTING ROOF SYSTEM TYPE SCHEDULE BELOW

R1

R2

R3

D4

RD

RTU

CU

EXISTING AIR VENTILATION UNIT

- INSTALL NEW FLASHING AND REINSTALL

HV

MECHANICAL SUBCONTRACTOR [231] SHALL COORDINATE THE DISCONNECTION AND RECONNECTION FOR ALL HVAC ROOF TOP EQUIPMENT REQUIRED TO BE RAISED ONTO NEW ROOF CURBS TO MEET NEW ROOF MEMBRANE WARRANTY HEIGHT REQUIREMENTS. THE DISCONNECTION AND RECONNECTION REFERS TO ALL GAS, ELECTRICAL AND DUCTWORK CURRENTLY CONNECTED TO EACH PIECE OF HVAC EQUIPMENT. HVAC EQUIPMENT REFERS TO ALL EXHAUST FANS, ROOF TOP UNITS, CONDENSERS, COMPRESSORS, AIR HANDLING UNITS OR GENERALLY ANY HVAC RELATED EQUIPMENT THAT IS

MOUNTED ON THE ROOF.

EXISTING SNOW GUARD

- TO BE REINSTALL, SAME LOCATION

SG

LIGHTNING PROTECTION SYSTEM

- TO BE REINSTALLED

LP

EXISTING REFRIGERATION

RECIPROCATING ON STEEL DUNNAGE

LIQUID CHILLER TO REMAIN.

- INSTALL NEW FLASHING

CH

FP

INSTALL NEW BALLASTED FALL

PROTECTION

D

NEW PAINTED DOOR, DOOR FRAME,

HARDWARE AND THRESHOLD

- TO BE INSTALLED

NOTE:

(VMI) VERTICAL MEMBRANE INSTALLATION ABOVE ROOF

VMI

TOTAL QUANTITY LF.LOCATION INDICATOR WALL DESCRIPTION

FURNISH AND INSTALL NEW VERTICAL PLYWOOD SUBSTRATE AND ROOF

MEMBRANE OVER EXISTING CONSTRUCTION.260 LF. ±

ROOF GENERAL NOTES

1. ALL WORK SHALL CONFORM TO THE LATEST EDITION OF THE MASSACHUSETTS BUILDING CODE.

2. THE INFORMATION SHOWN ON THIS PLAN WAS COMPILED FROM VARIOUS SOURCES AND MAY NOT REFLECT ACTUAL CONDITIONS AT THE TIME OF CONSTRUCTION. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS IN THE

FIELD, AND MUST NOTIFY ARCHITECT OF ANY DISCREPANCIES.

3. ALL DIMENSIONS SHOWN +/- ON ROOF PLANS SHALL BE VERIFIED IN FIELD

4. ANY CONDITION NOT FOUND DETAILED SHALL BE CONSTRUCTED IN A MANNER SIMILAR TO THAT OF THE ROOF

MEMBRANE MANUFACTURERS TYPICAL DETAILS.

5. ALL MATERIALS SHOWN ON THE DRAWINGS ARE NEW UNLESS OTHERWISE NOTED.

6. ALL EQUIPMENT, PIPES, WIRES, AND STRUCTURE TO BE PROTECTED DURING CONSTRUCTION. ALL ELECTRICAL AND HVAC EQUIPMENT REQUIRING DISCONNECTION AND RECONNECTION FOR INSTALLATION OF NEW ROOF SYSTEM SHALL BE PERFORMED BY A LICENSED ELECTRICIAN, PLUMBER AND HVAC CONTRACTOR UNDER

THE ROOF REPLACEMENT CONTRACT.

7. REMOVE EXISTING EQUIPMENT, RAISE CURB AND REINSTALL EXHAUST FAN TO MAINTAIN ROOF MEMBRANE MANUFACTURER'S MINIMUM FLASHING HEIGHT REQUIREMENTS OR DIMENSION SHOWN. EQUIPMENT SHALL BE DISCONNECTED AND RECONNECTED BY LICENSED ELECTRICIANS, PLUMBERS AND HVAC CONTRACTORS UNDER

THE ROOF REPLACEMENT CONTRACT. BY [231]

8. PROVIDE TAPERED INSULATION CRICKETS ALONG HIGH SIDE OF ROOF-TOP PENETRATIONS GREATER THAN 30 INCHES WIDE. SOME CRICKETS FOR THE ROOF TOP PENETRATIONS ARE NOT SHOWN ON ROOF PLANS FOR

CLARITY; REFER TO APPLICABLE DETAILS FOR MORE INFORMATION.

9. THE GENERAL CONTRACTOR IS REQUIRED TO CLEAN ALL INTERIOR ROOMS BENEATH AREAS OF ROOF WORK PRIOR TO TURNING OVER AFFECTED ROOMS BACK TO THE OWNER. COORDINATE CONSTRUCTION SCHEDULE WITH OWNER PRIOR TO COMMENCEMENT OF WORK. BROOM SWEEP ALL FLOOR SURFACES, VACUUM AND DUST

WIDE ALL SHELVING, FURNITURE, AND EQUIPMENT.

10. PERIMETER WOOD BLOCKING ALONG ROOF EDGES SHALL BE THE SAME HEIGHT FOR THAT ROOF LEVEL. THE CONTRACTOR SHALL SET TOP OF WOOD BLOCKING BASED ON THE HIGHEST THICKNESS OF THE INSULATION, COVER BOARD, AND CRICKET INSULATION. PROVIDE FIBERBOARD TAPERED EDGE STRIPS FULLY ADHERED TO SLOPE FROM PERIMETER WOOD BLOCKING TO INSULATION HEIGHT WHERE WOOD BLOCKING IS ABOVE INSULATION HEIGHT, EXCEPT AT EDGES WITH TAPERED CRICKETS. PERIMETER FASCIA SHALL BE ALL THE SAME HEIGHT BASED ON GREATEST NECESSARY HEIGHT FOR CRICKETS. FASCIA COVERS SHALL OVERLAP MASONRY

AND METAL WALLS BELOW BY A MINIMUM OF 2 INCHES.

11. EXPANSION JOINT SHALL TAPER OFF AT THE EDGE OF THE ROOF SO THAT THE EXPANSION JOINT IS AT ROOF

LEVEL AT THE FACE OF THE BUILDING.

12. PROVIDE WALKWAY PADS AT TOP AND BOTTOM OF ALL LADDERS, AT ROOF HATCHES AND ROOF ACCESS DOORS. PROVIDE WALKWAY PADS SURROUNDING EACH RTU AND THE DIRECT PATH BETWEEN THE ROOF ACCESS

POINT AND THE EQUIPMENT. SEE ROOF PLAN.

13. THE GENERAL CONTRACTOR SHALL LOCATE ALL EXISTING ELECTRICAL CONDUITS MOUNTED TO THE UNDERSIDE OF EXISTING ROOF DECK PRIOR TO MECHANICAL ATTACHMENT OF BASE LAYER OF ROOFING AND

WOOD BLOCKING TO AVOID PENETRATION OF CONDUIT.

14. PROVIDE EXTENDED FASTENERS AT LIGHTNING PROTECTION SYSTEM ASSEMBLY AS DETAILED. COORDINATE

FINAL CONSTRUCTIONS WITH ELECTRICAL DRAWINGS [261].

15. ROOF SHALL BE PHOTOVOLTAIC READY

RH

VMI

ROOF SYSTEM TYPE SCHEDULE

TOTAL: 515 LF. ±

250 LF. ±CFI CFI

PROVIDE NEW MASONRY WORK, NEW WEEPS AND NEW

COUNTERFLASHING TO RAISE WALL MEMBRANE TERMINATION TO MEET

CURRENT…