26QA218 Attach 1 - SOW.pdf

PDF 606 KB Posted

Attached to
FY26 SFS Lateral Filing System
Solicitation number
FA462026QA218
Issued by

About this file

This is a Statement of Work (SOW) for the procurement and installation of a lateral filing system at Fairchild Air Force Base, WA, under contract number FA462026QA218, issued in February 2026.

The contractor shall furnish one new Kardex Megamat 125 VCM lateral filing system (MEG 125-1311S VCM or brand name equal), including delivery, assembly, installation, operational testing, and disposal of all waste and debris in accordance with federal, state, and local guidelines. The unit must meet specific salient characteristics including overall dimensions of 90.56" H x 103.54" W x 47.32" D (with 12" work counter), 13 lateral carriers with drawers for top tab folders, minimum file capacity of 1,261 linear file inches, manual crank backup capability for electric outages, bi-parting door with lock, self-balancing design, automatic interior task lighting, computer interface to work counter controller, fixed standing position posting board, and high-quality steel construction with automotive grade painted finish. The unit shall be self-contained requiring no building modifications and must plug into existing 110-volt wall outlet or be hard-wired. Standard manufacturer 2-year parts and labor warranty applies. All contractor personnel entering Fairchild AFB must abide by security regulations, pass background checks, and provide full name, date of birth, social security number, driver's license issuing state, and license number. Performance location is Fairchild AFB with specific buildings/locations identified in appendices by Contract Line Item Number (CLIN 0001). The contractor must test system operability and provide operator training prior to acceptance.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

for

FY26 SFS LATERAL FILING SYSTEM

February 2026

FA462026QA218

Attachment 1 - Statement of Work

Statement of Work (SOW) for

FY26 SFS Lateral Filing System Fairchild AFB, WA

1. BACKGROUND: Fairchild Air Force Base maximizes space utilization through the use of lateral filing systems. This effective method of storing supplies allows for efficient utilization of space and ease of retrieval.

2. SCOPE OF WORK: The Contractor shall furnish new lateral filing system, test for operational capability and disposal of any debris/waste in accordance with all state, local, and federal guidelines and regulations.

3. OBJECTIVES: Ensure efficient supplies, records and materials storage and handling.

4. REQUIREMENTS: BRAND NAME OR EQUAL Parts numbers and salient characteristics is specified by CLIN within Appendix A. All parts provided shall be new. No refurbished materials will be accepted. Standard manufacturer warranties on parts and labor rates shall apply.

5. SECURITY REQUIREMENTS: All personnel employed by the Contractor in the performance of this contract, or any representative of the Contractor entering the government installation, shall abide by all Fairchild Air Force Base security regulations. Personnel performing the work requested will be escorted for the duration on the installation. Individuals must be able to pass a background check that will be conducted prior to entry of the installation. Individuals performing the work will be required to provide their full name, DOB, SSN, driver’s license issuing state and license number to gain access to the installation.

6. PLACE OF PERFORMANCE: All work will be performed on Fairchild Air Force Base in the buildings/locations specified in the appendices and by CLIN.

7. APPENDIX:

Appendix A: CLIN 0001

FA462026QA218

Appendix A: CLIN 0001

BRAND NAME OR

EQUAL

Part Number

Item Description

Qty MEG 125-1311S VCM Kardex Megamat 125 VCM 1

Salient Characteristics:

1. Each unit shall have overall dimensions of 90.56” H (+/- 1”) x 103.54” W (+/- 1”) x

47.32" D (+12” Including Work Counter) (+/- 1”)

2. Each unit shall include 13 Lateral Carriers with drawers for filing Top Tab Folders.

3. Unit shall Include standard manufacturer 2-year parts and labor warranty.

4. Unit shall provide a manual drive crank capable of moving the carriers in case of electric outage for easy access to content within the unit.

5. Units will come with a fixed standing position posting board at 39.4” high with light gray finish.

6. Unit will hold a minimum File capacity, linear file inches (L.F.I.) of 1,261 LFI, optimized to fit the space allocated.

7. Computer Interface – To controller located in work counter.

8. Unit will offer a manual bi-parting door with lock.

9. The model shall have self- balancing design such that units will not jam, tilt or skew, or otherwise become inoperable due to heavy shelves, empty shelves or uneven loading.

10. The unit shall have an automatic on/off interior task lighting integrated into the unit.

11. The unit shall be self-contained and not require any building modifications to install (i.e.

subfloor). Vendor shall be responsible to ensure fit, form, and function of the file system including operator access within this room while maximizing capacity in LFI. The unit shall allow entry and exit access, and adequate access to the transaction counter of the unit.

12. Materials – This high-density vertical system shall be of high-quality steel construction with an automotive grade painted finish.

13. Electrical – Unit to plug into existing 110-volt wall outlet or hard wired into the outlet.

CLIN 0001 Statement of Work specific information:

1. The contractor shall coordinate delivery, assembly, and installation of the BRAND NAME or EQUAL MEG 125-1311S VCM unit.

2. The contractor shall dispose all waste, garbage, or debris in accordance with all federal, state, and local guidelines and regulations.

3. The contractor shall test operability and provide training on the system prior to acceptance.

FA462026QA218