This is a Requirements document for weighted system railings (guard rails) to be procured and delivered to the U.S. Embassy in Panama City, prepared by the U.S. Department of State, Bureau of Overseas Buildings Operations in August 2026.
The requirement is for a rooftop security guard rail system to be delivered door-to-door to the embassy compound at AVE. Basilio Demetrio Lakas, Clayton, Panama. Installation services are excluded from the scope. The guard rail must be EN14122 Class A approved and independently tested, meeting OSHA Regulation 29 CFR 1910.23 for guardrail systems. Design specifications include a minimum height of 42 inches, capability to withstand a 200-pound load in any direction to the top rail, and compatibility with roof slopes up to 10 degrees. Materials must consist of galvanized steel pipe (1-1/2 inches schedule 40), galvanized tube (12 gauge, 1-1/2 inches), galvanized counterweight levers (1-1/4 inches), molded recycled PVC counterweights, and Class 30 gray iron mounting bases weighing 96 pounds with rubber pads to protect the roof membrane. All fasteners and securing pins must be stainless steel or galvanized, with pins including a collared design and lanyard connected to a lynch pin. Receiver posts must incorporate positive locking systems—friction locking is prohibited—and include drain holes. Compliance is required with Department of State physical security standards (12 FAM, 12 FAH-5, 12 FAH-6), SHEM guidelines for hazard management during delivery, OSHA standards for safe material handling and transportation, and EM 385-1-1 recommendations regarding wind load design and proper material handling techniques. All delivery documentation must include material specifications, safety certifications, and compliance verification with Department of State security standards.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Requirements
Weighed System Railings at U.S. Embassy Panama City
Post Location: Panama, Panamá
Address: AVE. Basilio Demetrio Lakas
Clayton
Prepared By: The US Department of State
MGT/FAC
Preparation Date: August 2026.
REQUIREMENTS
Weighed System Railings at U.S. Embassy Panama City
General Description
The Guard Rail is a rooftop security solution designed to provide physical barriers that deter unauthorized access while ensuring safety and compliance with Department of State regulations. This rail will be delivered door-to-door to the Panama USA Embassy compound.
Installation services are not included in this scope of work.
The US Embassy Panama, has the requirement of getting this guard rail, as a commercial Item which only includes delivery door to door at Panama City, Clayton, US Embassy Panama, Calle Demetrio Lakas.
Product Specifications
The fence system must meet the following specifications, incorporating features from industry-leading designs:
1. Compliance and Certification:
o EN14122 Approved Class A Permanent Protection System.
o Independently tested and approved.
o Meets OSHA Regulation 29 CFR 1910.23 for guardrail systems.
2. Design Features:
o Height: Minimum height of 42 inches (1067 mm) to provide a pedestrian egress barrier.
o Structural Load: Capable of withstanding a minimum load of 200 lb (90.7 kg) in any direction to the top rail.
o Slope Compatibility: Suitable for roof slopes of up to 10°.
o Modular System: Offers maximum flexibility for different roof types.
3. Materials:
o Pipe: Steel, 1-1/2 inches (48 mm) schedule 40, galvanized.
o Tube: Galvanized tube, 12 gauge, 1-1/2 inches, 1.90 inches (48 mm) OD.
o Rails and Posts: Galvanized tube, 12 gauge, 1-1/2 inches, 1.90 inches (38
mm) diameter.
o Counterweight Levers: Galvanized tube, 12 gauge, 1-1/4 inches, 1.660 inches (38 mm) diameter.
o Counterweights: Molded recycled PVC with one fixing collar per counterbalance.
o Mounting Bases: Steel bases, galvanized, with rubber pads on the underside to prevent penetration of the roof membrane.
4. Hardware:
o Fasteners: Stainless steel or galvanized.
o Securing Pins: 1010 carbon steel, zinc-plated, and yellow chromate dipped.
Pins must include a collared pin and lanyard connected to a lynch pin.
5. Safety Standards:
o System must include top and mid-rails in accordance with OSHA standards.
o Receiver posts must have a positive locking system into slots that allow rails to be mounted in any direction. Friction locking systems are not allowed.
Receiver posts must include a drain hole.
6. Mounting Bases:
o Class 30 gray iron material cast with four receiver posts.
o Base weight: 96 lbs and 43 lbs per square foot.
o Rubber pads must be provided on the bottom of bases to protect the roof membrane.
Safety Regulation Requirements
The Department of State's safety regulation requirements ensure personnel, facilities, and operations are protected across various domains. For this project, the following safety regulations apply:
1. Department of State Standards:
o Compliance with physical security standards outlined in 12 FAM Diplomatic Security, 12 FAH-5 Physical Security Handbook, and 12 FAH-6 Overseas Security Policy Board (OSPB) Security Standards and Policy Handbook.
112 FAM 311.2, Physical Security of Facilities Abroad
2. Safety, Health, and Environmental Management (SHEM):
https://fam.a.state.sbu/FAM/12FAM/12FAM0310.html o Adherence to SHEM guidelines for hazard identification, reporting, and abatement during delivery.
3. Occupational Safety and Health Administration (OSHA):
o Delivery personnel must comply with OSHA standards for safe handling and transportation of materials.
4. Recommendations from EM 385-1-1:
The U.S. Army Corps of Engineers Safety and Health Requirements Manual (EM 385- 1-1) provides additional safety recommendations for rooftop guardrails:
o Wind Load Considerations: Rooftop fences must be designed to withstand wind loads, particularly in areas prone to high winds. EM 385-1-1 recommends consulting structural engineers to ensure compliance with wind resistance standards.
o Material Handling: Delivery and handling of materials must follow EM 385-1- 1 Section 14, which requires proper lifting techniques, use of mechanical aids, and adherence to weight limits to prevent injuries.
Delivery Requirements
• The fence must be delivered door-to-door to the U.S. Embassy Panama City compound.
• Delivery must include all necessary documentation, including material specifications, safety certifications, and compliance with Department of State security standards.
This requirements ensures compliance with all relevant Department of State regulations, safety standards, and operational requirements for the delivery of a Non-Destructive Fence for rooftop at the Panama USA Embassy.
File details come from the government source that posted it. Updated .