2608-OC_Security_Wall-Elec-For_Permit_(26.08.18).pdf

PDF 7 MB Posted

Attached to
Courthouse Annex Security Wall
Solicitation number
ITB FM 02-27
Issued by
Okaloosa County, Florida

About this file

This electrical permit drawing set is for the Courthouse Annex Security Wall project at 1940 Lewis Turner Boulevard in Fort Walton Beach, Florida, prepared by HG Engineers on behalf of the Board of County Commissioners of Okaloosa County. The project encompasses the design and installation of electrical systems to support a new exterior security wall featuring a controlled access gate and gate operator. The electrical work includes installation of a NEMA 3R 30-amp two-pole disconnect switch for gate power, weatherproof junction boxes for telecommunications and door power requirements, conduit routing for a new powered gate operator, controlled access door lighting, and associated wiring throughout the facility. The drawings specify complete electrical infrastructure including underground conduit details, wall penetration requirements, interior routing through hallway ceiling grid and holding cell building roof, and connections to the existing electrical panel. The engineered design was prepared by licensed Florida Professional Engineers Christopher A. Garick (PE No. 53924), Thomas A. Alexander (PE No. 73172), Daniel J. White (PE No. 73790), and Caleb W. Leonard (PE No. 91782), with the final permit version dated August 18, 2026.

The electrical specifications require compliance with the National Electric Code, Florida State Building Code, and local ordinances, with all exposed conduit, boxes, straps, and hangers painted to match adjacent finishes. The work mandates installation in concealed-type construction using Schedule 40 PVC for underground conduits, IMC for exterior exposed work, and EMT conduit for branch circuits in open spaces above ceiling. All conductors must be copper with type THWN or THHN insulation rated at 600 volts, with green ground conductors provided throughout. Flexible conduit connections are required for all motor final connections, and bushings must be provided on all conduit. The contractor must field-verify existing conditions prior to commencement, obtain architectural approval for all light fixtures, and complete all work in a neat and workmanlike manner, with a one-year warranty period from final acceptance to correct any defects.

View the file

Other files

File Type Posted
Courthouse_Annex_Security_Wall.pdf PDF
FWBCH_Annex_Wall.pdf PDF
Specs_and_Keynotes.png PNG image
2608-OC_Security_Wall-Arch-For_Permit_(26.08.18).pdf PDF
2608-OC_Security_Wall-Struc-For_Permit_(26.08.18).pdf PDF
DraftAgreement_02-27.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

E L E C T R I C A L G E N E R A L N O T E S

A. FINAL CONNECTION TO ALL MOTORS SHALL BE WITH FLEXIBLE CONDUIT CONNECTION.

B. PROVIDE GREEN GROUND CONDUCTOR IN ALL CIRCUITS - SIZE PER N.E.C.

C. ALL EXPOSED CONDUITS, BOXES, STRAPS AND HANGERS IN THE CONTRACT AREA WHETHER NEW OR EXISTING THAT ARE PART OF THE ELECTRICAL SYSTEM SHALL BE PAINTED TO

MATCH ADJACENT FINISH.

D. GENERAL CONTRACTOR SHALL FIELD-VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING ANY WORK, AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.

FAILURE TO DO SO INDICATES THAT THE CONTRACTOR ACCEPTS THE CONDITIONS AS THEY EXIST, AND SHALL PERFORM THE WORK REQUIRED AS SHOWN AND SPECIFIED.

E. THE ELECTRICAL CONTRACTOR SHALL OBTAIN AND REVIEW THE MECHANICAL AND SPECIAL EQUIPMENT SUBMITTALS PRIOR TO SUBMITTING THE ELECTRICAL SUBMITTALS. ANY ELECTRICAL EQUIPMENT, CONDUIT, AND WIRE SIZE CHANGES RESULTING FROM THIS REVIEW SHALL ALSO BE SUBMITTED FOR APPROVAL.

F. PROVIDE BUSHINGS ON ALL CONDUIT.

G. COMPLY WITH ALL LOCAL CODE, LAWS, AND ORDINANCES APPLICABLE TO ELECTRICAL WORK, THE STATE BUILDING CODE AND THE NATIONAL ELECTRIC CODE. OBTAIN ALL PERMITS

REQUIRED BY LOCAL ORDINANCES.

H. OBTAIN ARCHITECTS APPROVAL OF ALL LIGHT FIXTURES PRIOR TO PURCHASING.

I. THE ELECTRICAL WORK SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. ALL NOT SO INSTALLED SHALL BE REMOVED AND REPLACED AT NO COST TO THE OWNER.

J. ALL WORK SHALL BE INSTALLED IN CONCEALED TYPE CONSTRUCTION. UNDERGROUND CONDUITS UP TO FIRST BOX IN CONCEALED CONSTRUCTION MAY BE SCH.40 PVC. EXTERIOR EXPOSED WORK SHALL BE I.M.C. BRANCH CIRCUIT CONDUIT RUN IN OPEN SPACES ABOVE CEILING OR IN WALLS MAY BE THINWALL (E.M.T.) CONDUIT 1/2" MIN. SIZE.

K. ALL CONDUCTORS LESS THAN 100A. SHALL BE COPPER #12 & #10 SOLID, #8 AND LARGER STRANDED, #6 AND SMALLER TO BE TYPE THWN, 600 VOLT INSULATION AND TYPE THWN OR THHN FOR #4 AND LARGER. ALUM. CONDUCTORS MAY BE USED FOR 100A. AND LARGER ONLY WHERE USED WITH COMPRESSION TERMINATIONS.

L. PROVIDE GROUNDING PER NATIONAL ELECTRIC CODE.

M. THE CONTRACTOR SHALL LEAVE THE ENTIRE ELECTRICAL SYSTEM INSTALLED IN PROPER WORKING ORDER, AND SHALL REPLACE WITHOUT ADDITIONAL COST, ALL WORK OR MATERIAL WHICH MAY DEVELOP DEFECTS, (ORDINARY WEAR AND TEAR OR DAMAGE RESULTING FROM IMPROPER HANDLING EXCEPTED) WITHIN A PERIOD OF ONE (1) YEAR FROM THE DATE OF

FINAL ACCEPTANCE BY THE OWNER.

DATA SYSTEM WALL OUTLET WITH ONE(1) RJ-45 JACK AND COVERPLATE; MT 18" AFF TO C/L UNLESS NOTED OTHERWISE - INSTALL 3/4"C WITH PULLRIBBON

RACEWAY INSTALLED CONCEALED IN WALLS AND/OR ABOVE CEILING

RACEWAY INSTALLED CONCEALED IN FLOOR SLAB AND/OR BELOW GRADE

RACEWAY INSTALLED EXPOSED

CONDUIT STUB UP WITH FLEXIBLE CONDUIT CONNECTION TO EQUIPMENT

FLEXIBLE CONDUIT CONNECTION

UP INTO CEILING SPACE.

PANEL; 120/208V; MT 72" AFF TO TOP

JUNCTION BOX; MOUNTED FLUSH IN WALL WITH BLANK COVER

A-1 ADJACENT TO ARROW INDICATES HOMERUN OF CIRCUIT NO. 1 TO PANEL A; "B" INDICATES FIXTURE TYPE; MARKS ACROSS RACEWAY RUN INDICATES THE NUMBER OF NO. 12 CONDUCTORS; UNLESS NOTED OTHERWISE NO MARKS INDICATES TWO NO. 12 CONDUCTORS AND ONE NO. 12 GREEN GROUND CONDUCTOR IN 1/2" CONDUIT

(2#12 & 1#12 GND-1/2"C)

E L E C T R I C A L L E G E N D A-1 'B'

-APPLIES TO ALL CORRIDOR, SMOKE AND FIRE RATED WALLS

NOT TO SCALE

WALL PENETRATIONS

NOTE:

SMALL DIAMETER GAPS

OPENINGS UP TO 3" DIA.

3"3" 3"3"

3"

OPENINGS OVER 3" DIA.

CENTERLINE OF STUDS

3"

MAX

6"6"

MAX

6"

MAXMAX

6"3"

IN ONE HOUR WALLS

3"

BUTTER BACK SIDE OF PATCH

WITH JOINT COMPOUND-DO NOT

STRIKE OFF EXCESS.

LEAVE SCREWS EXPOSED

MAXIMUM GAP 1/8"

NON-SMOKE ONE HOUR OR LESS

NO TREATMENT. SMOKE WALLS

SURFACE BEAD OF USG ACOUSTICAL

TREATMENT.

MAXIMUM GAP 1/4"

FILL WITH JOINT COMPOUND

ONE HOUR OR SMOKE WALLS

MAXIMUM GAP 1/2"

FILL WITH USG ACOUSTICAL

SEALANT REF CEG 1-25-85.

ONE HOUR OR SMOKE WALLS

JOINT AT 2ND

LAYER (2HR)

TYPE 'G' SCREWS-MINIMUM

2 PER SECTION

TYPE 'G' SCREWS 6" O.C. MAXIMUM

MINIMUM 2 TYPE 'S' SCREWS PER SECTION

UNDERGROUND CONDUIT DETAIL

NOT TO SCALE

FINISHED GRADE

RED MARKER TAPE

CONDUIT

24" MIN.

12"

DISCONNECT SWITCH

DESCRIPTION NOMENCLATURE

XX/X/XX

AMPERE RATING NEMA RATING

NUMBER OF POLES

NON-FUSED DISCONNECT SWITCH; AMP SIZE AS NOTED

RE

NG

LE

:59

P M

- E 1 L

EG

EN

D

NO

TE

S.

dw g

Job No.Christopher A. Garick; FL. PE No.53924 Thomas A. Alexander; FL. PE No.73172 Daniel J. White; FL. PE No.73790 Caleb W. Leonard; FL. PE No.91782

HG Engineers 142 Eglin Parkway SE Fort Walton Beach, Florida, 32548 E-mail: office@hgengineers.com Ph: 850.243.6723 Fl. Authorization No.00006680

26042 llc

D A

TE

D R

A W

N B

Y:

P R

O

JE

C T

N O

R E

VI

S

IO

N

S a ug

C .P

A S

TO

R

IU

S

A

U G

FO

R

P E

R M

IT

P R O

FESS IONA L ENG

I N E

E R

CH

R

IS

TO

PHER A . GAR

ICKL I C E N S E

STATE OF

No. 53924

FLO RIDA

FO

R

T W

A

LT

O N

B E

A C

H , F

LO

R

ID

A

A nn ex C ou rth ou se

S ou th

E nd

L E

W

IS

T U

R N

E R

B O

U

LE

VA

R

D

E xt er io r S ec ur ity

W al l E

LE

G

E N

D

N O

TE

S

COURTHOUSE ANNEX

J J

KEYNOTES

PROVIDE WEATHER-PROOF JUNCTION BOX WITH

TWO CAT 6 CABLE BACK TO TELECOM ROOM IN 1"

SCHEDULE 40 PVC CONDUIT, REFER TO INTERIOR

PLANS FOR ROUTING. MOUNT 4' AFG. LEAVE 18"

COILED IN JUNCTION BOX.

PROVIDE WEATHERPROOF JUNCTION BOX WITH 3

#10 AWG COPPER WIRE IN 3/4" SCHEDULE 40 PVC

CONDUIT FOR DOOR POWER REQUIREMENTS.

REFER TO INTERIOR PLANS FOR ROUTING.

MOUNT 4' AFG.

PROVIDE NEMA 3R 30AMP TWO POLE

DISCONNECT WITH 4 #6 AWG COPPER WIRE IN 1"

SCHEDULE 40 PVC CONDUIT FOR GATE POWER

REQUIREMENTS. REFER TO INTERIOR PLANS FOR

ROUTING. MOUNT 4' AFG.

REFER TO SHEET E3 FOR CONDUIT ROUTING

CONTINUATION.

RUN 3/4" SCHEDULE 40 PVC CONDUIT WITH 3 #10

AWG WIRE FOR LIGHTING.

UP

J

NEW GATE OPERATOR

UP

UP

'WB'

'WB'

'WB'

'WB'

'WB'

'WB'

'WB'

'WB'

'WB'

'WB'

'WB''WB'

'WB'

TELECOM PATHWAY FOR GATE OPERATOR

POWER PATHWAY FOR GATE OPERATOR

POWER PATHWAY FOR

CONTROLLED ACCESS

DOOR AND LIGHTING.

RE

NG

LE

:59

P M

- E 2 E

LE

CT

RI

CA

L S

IT

E

PL

AN

.dw g

Job No.Christopher A. Garick; FL. PE No.53924 Thomas A. Alexander; FL. PE No.73172 Daniel J. White; FL. PE No.73790 Caleb W. Leonard; FL. PE No.91782

HG Engineers 142 Eglin Parkway SE Fort Walton Beach, Florida, 32548 E-mail: office@hgengineers.com Ph: 850.243.6723 Fl. Authorization No.00006680

26042 llc

D A

TE

D R

A W

N B

Y:

P R

O

JE

C T

N O

R E

VI

S

IO

N

S a ug

C .P

A S

TO

R

IU

S

A

U G

FO

R

P E

R M

IT

P R O

FESS IONA L ENG

I N E

E R

CH

R

IS

TO

PHER A . GAR

ICKL I C E N S E

STATE OF

No. 53924

FLO RIDA

FO

R

T W

A

LT

O N

B E

A C

H , F

LO

R

ID

A

A nn ex C ou rth ou se

S ou th

E nd

L E

W

IS

T U

R N

E R

B O

U

LE

VA

R

D

E xt er io r S ec ur ity

W al l

ELECTRICAL SITE PLAN

1" = 10'-0" 5' 10' 20'

E

E

LE

C

TR

IC

A

L S

IT

E

P

LA

N

TELECOM ROUTING FOR NEW CONTROLLED ACCESS GATE & GATE OPERATOR

THROUGH HALLWAY CEILING GRID. SEAL PENETRATIONS AS REQUIRED.

POWER CONDUIT ROUTING FOR NEW CONTROLLED

ACCESS GATE & NEW LIGHTING. RUN OVER ROOF OF

HOLDING CELL BUILDING. SEAL PENETRATIONS AS

REQUIRED.

ROUTING FOR POWER CONDUIT ROUTING FOR

NEW POWERED GATE OPERATOR

RUN OVER ROOF OF HOLDING CELL BUILDING.

POKE THRU WALL, SEAL

PENETRATION AS REQUIRED. RUN

UP AND OVER HOLDING CELL ROOF

TELECOM CONDUIT FOR NEW GATE

OPERATOR. RUN HIGH ALONG WALL.

REFER TO SHEET E2 FOR CONTINUATION.

REFER TO SHEET E2 FOR CONTINUATION.

PANEL NQ1A

LEAVE NEW CAT 5 CABLES WITH 10' COILED. LABEL AS REQUIRED.

RE

NG

LE

:59

P M

- E 3 E

LE

CT

RI

CA

L I

NT

ER

IO

R

RE

FE

RE

NC

E.

dw g

Job No.Christopher A. Garick; FL. PE No.53924 Thomas A. Alexander; FL. PE No.73172 Daniel J. White; FL. PE No.73790 Caleb W. Leonard; FL. PE No.91782

HG Engineers 142 Eglin Parkway SE Fort Walton Beach, Florida, 32548 E-mail: office@hgengineers.com Ph: 850.243.6723 Fl. Authorization No.00006680

26042 llc

D A

TE

D R

A W

N B

Y:

P R

O

JE

C T

N O

R E

VI

S

IO

N

S a ug

C .P

A S

TO

R

IU

S

A

U G

FO

R

P E

R M

IT

P R O

FESS IONA L ENG

I N E

E R

CH

R

IS

TO

PHER A . GAR

ICKL I C E N S E

STATE OF

No. 53924

FLO RIDA

FO

R

T W

A

LT

O N

B E

A C

H , F

LO

R

ID

A

A nn ex C ou rth ou se

S ou th

E nd

L E

W

IS

T U

R N

E R

B O

U

LE

VA

R

D

E xt er io r S ec ur ity

W al l

ELECTRICAL INTERIOR REFERENCE

3/32" = 1'-0" 5'-4" 10'-8" 21'-4"

E

E

LE

C

TR

IC

A

L

IN

TE

R

IO

R

R E

FE

R

E N

C E

2026-08-18T14:51:19-0500
Christopher A Garick

File details come from the government source that posted it. Updated .