260610_VIB Charlottesville Elevator Addition Drawings_Bid Submission - R1 1.pdf
PDF 23 MB Posted
- Attached to
- 702-27-03, Freight Elevator Addition at Virginia Industries for the Blind - Charlottesville
- Solicitation number
- IFB-122042
- Issued by
- Albemarle County, Chesapeake City, Virginia
About this file
This is a bid submission document for architectural and engineering drawings related to a freight elevator addition project at the Virginia Industries for the Blind (VIB) facility in Charlottesville, Virginia, under the Department for the Blind and Vision Impaired (DBVI). The project involves the construction of a new hydraulic freight elevator at 1102 Monticello Road, Charlottesville, VA 22902, with a total addition area of 1,902 square feet across multiple floors. Upon completion and operational status of the new elevator, the existing freight elevator will be removed and the concrete floor infilled. The project is classified as a Chapter 8 Addition and Chapter 6 Alteration under the Virginia Existing Building Code (VEBC) 2021 Edition and must comply with the Virginia Uniform Statewide Building Code (VUSBC) 2021 Edition. The bid submission was completed on June 10, 2026, and includes comprehensive architectural, structural, mechanical, plumbing, electrical, and fire protection drawings. The project is designated as a sub-project (PC No. 702-18581-002) to the larger VIB renovation project (PC No. 702-18581-000), which will be bid separately. The facility will remain occupied and operational throughout all construction phases, requiring careful phasing and temporary egress provisions.
The construction phasing consists of seven phases beginning with temporary barrier construction and removal of the existing lift, followed by new freight elevator construction and commissioning, removal of temporary barriers, removal of the existing freight elevator, slab infillment, and restoration of all finishes to pre-construction condition. The building is a non-separated mixed-use facility with Business (B) and Storage (S-1) occupancy classifications, constructed in 1931 with the last major renovation in 2001, covering 68,658 square feet across five stories including basement and sub-basement levels. The project includes delegated design items for fire suppression, fire alarm systems, bolted and welded connections, and duct and pipe hangers, all requiring designs by certified design professionals licensed in Virginia with shop drawings signed and sealed per project manual requirements. An asbestos inspection was performed with no asbestos-containing materials (ACM) found, and a lead inspection report is included in the project specifications. The project received final approval from the Art and Architectural Review Board (AARB) on August 2, 2024.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 260610_VIB Charlottesville Elevator Addition Project Manual_ Bid Submission - R1 1.pdf | ||
| REQUIRED FORMS (3).docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXISTING TO REMAIN
EXISTING TO BE DEMOLISHED
NEW CONSTRUCTION
PROJECT LOCATION
INTERSTATE 64
LONG ST
R
IV
A N N A R
IV
E R
E HIGH ST
M O
N T
IC
E
LL
O
A V E
RI
D G E
S T
W M
AIN ST
N
MONTICELLO AVE
CARLTON AVE
M O
N T
IC
E
LLO
R D
BELMONT AVE
LEO
N A R D R
D
BAINBRIDGE S
T
PROJECT LOCATION
N
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
G0.01e
Cover Sheet
1102 Monticello Road Charlottesville, VA 22902
APPLICABLE CODES
THE BUILDING CODE AUTHORITY IS THE VIRGINIA DEPARTMENT OF GENERAL
SERVICES (DGS), DIVISION OF ENGINEERING AND BUILDINGS (DEB).
THE BUILDING CODE FOR THIS PROJECT IS THE VIRGINIA UNIFORM STATEWIDE
BUILDING CODE (VUSBC) 2021 EDITION, EFFECTIVE JANUARY 18, 2024. ALL WORK
SHALL CONFORM TO THE BUILDING CODE.
ALL WORK SHALL CONFORM TO THE 2021 VIRGINIA CONSTRUCTION CODE
INCLUDING VCC CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION AND THE 2021
INTERNATIONAL FIRE CODE CHAPTER 33 FIRE SAFETY DURING CONSTRUCTION AND
DEMOLITION.
THE PROJECT IS CLASSIFIED AS A CHAPTER 8 ADDITION AND CHAPTER 6
ALTERATION OF THE VIRGINIA EXISTING BUILDING CODE (VEBC) 2021 EDITION.
THE BUILDING IS DESIGNATED UNDER THE CONSTRUCTION AND PROFESSIONAL
SERVICES MANUAL (CPSM) 2025 EDITION, REVISION 0.
THE ACCESSIBILITY CODE FOR THIS PROJECT IS THE ADA STANDARDS FOR
ACCESSIBLE DESIGN (ASAD) 2010 EDITION EXCEPT WHEN IN CONFLICT WITH ANSI
A117.1-2017 AS CLARIFIED IN SECTION 4.2.2 OF THE CPSM 2024 EDITION.
THE FIRE CODES FOR THIS PROJECT ARE THE VIRGINIA STATEWIDE FIRE PREVENTION
CODE 2021 EDITION.
CODE SUMMARY
ORIGINAL YEAR BUILT
LAST MAJOR RENOVATION/ADDITION:
LAST MAJOR RENOVATION BUILDING CODE::
USE & OCCUPANCY CLASSIFICATION:
CONSTRUCTION TYPE:
SPRINKLERED:
FIRE ALARM:
EXISTING BUILDING AREA:
EXISTING BUILDING HEIGHT:
PROJECT AREA:
EXISTING ELEVATOR TYPE:
NEW FRIEGHT ELEVATOR TYPE:
BOCA 1996
NON-SEPARATED MIXED USE BUSINESS (B) AND
STORAGE (S-1). SEPARATED MIXED USE FACTORY (F-1)
1B
YES
YES
68,658 SF
46.15' (5 STORIES INCLUDING BASMENT & SUB
BASEMNET
1,902 SF
HYDRAULIC
HYDRAULIC
LOCATION MAP
PHASING
General
G0.01e Cover Sheet
G0.02e Symbols, Materials, Abbreviations, & Project Information
G0.03e Temporary Construction Details
G1.01e Egress, Occupancy & Fire Resistance Rating Plan
G1.02e Egress, Occupancy and Fire Resistance Rating Plan
G2.01e UL Details
G2.02e UL Details
G2.03e UL Details
G2.04e UL Details
G2.05e UL Details
G2.06e UL Details
G2.07e Boring Logs
Civil
C400e Site Plan
C401e Details
Architectural
AD1.01e Partial Demolition Floor Plans
AD3.01e Demolition Floor Sections
A1.01e Partial Floor Plans
A1.02e Partial Floor Plans and Elevator Elevations
A2.01e Freight Elevator Elevations
A3.01e Elevator Infill Sections
A4.01e Enlarged Freight Elevator Plans and Sections
A4.02e Enlarged Freight Elevator Details
A4.03e Enlarged Freight Elevator Details
Structural
S0.01e Structural Notes
S0.02e Structural Notes
S1.01e Sub-Basement Foundation Plan
S1.02e Basement Framing & Foundation Plan
S1.03e First Floor Framing & Foundation Plan
S1.04e Second Floor Framing Plan
S1.05e Third Floor Framing Plan
S1.06e Roof Framing
S3.01e Sections and Details
S5.01e Typical Details
Mechanical
M0.01e General Notes, Symbols and Abbreviations
MD1.01e Partial Mechanical Demolition Plans
M1.01e Partial Mechanical Plans
M6.01e Mechanical Schedules
M7.01e Mechanical Details and Controls
Plumbing
P0.01e General Notes, Symbols and Abbreviations
P1.01e Partial Plumbing Plans, Riser Diagram, Schedule and Details
Electrical
E0.01e General Notes, Symbols and Abbreviations
ED1.01e Partial Electrical Demolition Plan
ED1.02e Partial Electrical Demolition Plan
SHEET INDEX
THE PROJECT CONSISTS OF THE CONSTRUCTION OF A FREIGHT ELEVATOR AT THE VIRGINIA INDUSTRIES FOR THE BLIND (VIB) FACILITY IN CHARLOTTESVILLE, VIRGINIA. ONCE THE NEW ELEVATOR IS OPERATIONAL, THE EXISTING FREIGHT ELEVATOR SHALL BE REMOVED AND THE CONCRETE FLOOR INFILLED. THE BUILDING
SHALL REMAIN OCCUPIED AND OPERATIONAL AT ALL TIMES.
DESCRIPTION OF WORK
ASBESTOS DISCLOSURE STATEMENT
LEAD-BASED PAINT DISCLOSURE STATEMENT
Renovate the VIB Facility in Charlottesville Freight Elevator Addition
Department for the Blind and Vision Impaired (DBVI)
HIGH PERFORMANCE BUILDING ACT STATEMENT
VECC COMPLIANCE STATEMENT
A MASS NOTIFICATION SYSTEM IS NOT REQUIRED AND WILL NOT BE PROVIDED.
MASS NOTIFICATION SYSTEM STATEMENT
THE EMERGENCY COMMUNICATIONS SYSTEM WILL BE MONITORED BY A THIRD PARTY MONITORING
COMPANY AS IS CURRENTLY IN PLACE.
EMERGENCY COMMUNICATIONS STATEMENT
IN ACCORD WITH THE VIRGINIA ENERGY CONSERVATION CODE (VECC), THE BUILDING SHALL COMPLY WITH
VECC SECTIONS C402 THROUGH C405 AND C408.
AN ASBESTOS INSPECTION WAS PERFORMED AND NO ACM WAS FOUND. THE ASBESTOS INSPECTION
REPORT IS INCLUDED AS AN APPENDIX TO THE PROJECT SPECIFICATIONS.
AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS HAS BEEN CONDUCTED AND CAN BE FOUND IN THE PROJECT SPECIFICATIONS. THIS REPORT IS PROVIDED FOR THE CONTRACTOR’S USE AND MAY NOT BE ALL INCLUSIVE. IT IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO EMPLOYEE EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE RECYCLED TO THE
EXTENT POSSIBLE.
BUILDING AREAS
EXISTING ADDITION TOTAL
SUB-BASEMENT: 5,580 SF 232 SF 5,818 SF
BASEMENT: 21,350 SF 232 SF 21,588 SF
FIRST FLOOR: 18,996 SF 232 SF 19,234 SF
SECOND FLOOR: 11,193 SF 232 SF 11,431 SF
THIRD FLOOR: 11,193 SF 232 SF 11, 431 SF
PENTHOUSE FLOOR: 346 SF 346 SF
TOTAL AREA: 68,658 SF 1,160 SF 69,848 SF
IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT FROM COMPLIANCE BECAUSE THE COST OF THE RENOVATIONS DOES NOT EXCEED 50% OF THE VALUE OF THE BUILDING.
VICINITY MAP
Architect
Cole & Denny Architects 333 N. Fairfax St., Suite 300 Alexandria VA, 22314
Setty & Associates IMEG PSI, Intertek 3040 Williams Drive, Suite 600 Fairfax, VA 22031
MPE & Fire Protection Engineers Structural Engineers
Structura Inc.
1414 Prince Street, Suite 200 Alexandria, VA 22314
Civil & Landscape Engineers
9900 Main Street, Fourth Floor Fairfax, VA 22031
Geotechnical Engineer
2930 Eskridge Road Fairfax, VA 22031
P.C. No. 702-18581-002
PER VUSBC
SUB-PROJECTS:
THE PROJECT TITLED RENOVATE THE VIB FACILITY IN CHARLOTTESVILLE FREIGHT ELEVATOR
ADDITION (PC No.:702-18581-002) IS A SUB-PROJECT TO THE PROJECT TITLED RENOVATE THE VIB FACILITY IN CHARLOTTESVILLE (PC No.: 702-18581-000), WHICH SHALL BE BID AND
SUBMITTED SEPARATELY.
“CONTACT VIRGINIA 811 AT 811, 1-800-552-7001, OR HTTPS://WWW.VA811.COM NO LESS THAN 72 HOURS PRIOR TO EXCAVATION AND DO NOT DISTURB THE SOIL UNTIL DIG TICKET HAS BEEN PROCESSED.
DIG NOTICE
FIRE-RESISTANCE RATING REQUIREMENTS
FOR BUILDING ELEMENTS (HOURS)
2021 VUBSC CONSTRUCTION TYPE 1B
PRIMARY STRUCTURAL FRAME 2
BEARING WALLS
EXTERIOR 2
INTERIOR 2
NON BEARING WALLS AND PARTITIONS
EXTERIOR 1
INTERIOR 0
FLOOR CONSTRUCTION AND ASSOCIATED
SECONDARY MEMBERS 2
ROOF CONSTRUCTION AND ASSOCIATED
SECONDARY MEMBERS 1
2021 VCC Table 601
ON AUGUST 2ND, 2024, THE DEPARTMENT FOR BLIND AND VISUALLY IMPAIRED (DBVI) RECIEVED
FINAL APPROVAL FROM THE ART AND ARCHITECTURAL REVIEW BOARD (AARB).
AARB
ED5.01e Partial Electrical Power Riser Diagram - Demolition
E1.01e Partial Electrical Lighting Plan - Sub Basement, Basement and First Floor Plan
E1.02e Partial Electrical Lighting Plan - Second, Third, and Roof Plan
E2.01e Partial Electrical Power and FA Plan - Basement and Sub Basement Floor Plan
E2.02e Partial Electrical Power Plan - Third and Roof Plan
E3.01e Partial Fire Alarm Plan - Sub Basement and Basement Plan
E3.02e Partial Fire Alarm Plan - First and Second Floor Plan
E3.03e Partial Fire Alarm Plan - Third Floor Plan
E5.01e Partial Electrical Power Riser Diagram - New
E5.02e Partial Fire Alarm Riser Diagram and Fire Alarm Operational Matrix
E6.01e Electrical Schedules
E6.02e Electrical Panel Schedules
E7.01e Electrical Details
Fire Protection
F0.01e General Notes, Symbols, and Abbreviations
FD1.01e Partial Fire Protection Demolition Plans
F1.01e Partial Fire Protection Plans
F1.02e Partial Fire Protection Plans and Detail
DELEGATED DESIGN LIST
DELEGATED DESIGN ITEMS SHALL BE DESIGNED BY A CERTIFIED DESIGN PROFESSIONAL LICENCE IN
THE COMMONWEALTH OF VIRGINIA. SHOP DRAWINGS AND SUBMITTALS SHALL BE SIGNED AND
SEALED IN ACCORDANCE WITH THE PROJECT MANUAL. THIS PROJECT INCLUDES THE FOLLOWING
DELEGATED DESIGN ITEMS:
1. FIRE SUPPRESSION*
2. FIRE ALARM*
3. BOLTED & WELDED CONNECTIONS
4. DUCT HANGERS
5. PIPE HANGERS
6. COMMON STEEL STRUCTURAL CONNECTIONS
7. LIGHT GAUGE STEEL
* INDICATES SYSTEMS WITH SHOP DRAWING / APPROVAL BY THE STATE BUILDING OFFICIAL AFTER
THE A/E REVIEWS AND APPROVES THE SHOP DRAWINGS
No. Revision Date
EARTH
GRANULAR FILL
CONCRETE
BRICK
CMU
GROUT
STEEL
WOOD LUMBER
FINISH LUMBER
PLYWOOD
GYPSUM WALLBOARD
BATT INSULATION
RIGID INSULATION
SEALANT
SEALANT & BACKER ROD
SEALANT & COMPRESSIBLE
MATERIAL
ROOM NAME &
NUMBER
PARTITION TYPE
DOOR TYPE
# WINDOW TYPE
LEVEL MARKER
KEYNOTE
SECTION REFERENCE
SECTION NUMBER
SHEET NUMBER WHERE
DETAIL IS LOCATED
SHEET NUMBER WHERE
DETAIL IS REFERENCED
FROM
DETAIL REFERENCE
DETAIL NUMBER
SHEET NUMBER
WHERE SECTION IS
REFERENCED FROM
SHEET NUMBER WHERE
SECTION IS LOCATED
ELEVATION REFERENCE
ELEVATION NUMBER
SHEET NUMBER WHERE
ELEVATION IS REFERENCED
FROM SHEET NUMBER WHERE
ELEVATION IS LOCATED
INTERIOR ELEVATION
ELEVATION NUMBER
SHEET NUMBER WHERE
ELEVATION IS LOCATED
SECTION NUMBER
SHEET NUMBER WHERE
SECTION IS LOCATED
Name
NAME
BORING B-2
BORING B-1
TRIBUTARY ROOF
DRAIN AREA
ROOF DRAIN CALCULATIONS
SIZE OF
EX ROOF DRAIN
NO. OF ROOF
DRAINS
AREA CAPACITY
PER ROOF DRAIN
TOTAL AREA
CAPACITY
TRIBUTARY
ROOF AREA
ADD. TRIBUTARY
ROOF AREA
NEW TOTAL TRIBUTARY
ROOF AREA
4" 3 3,070 SF 9,210 SF 5,636 SF 272 SF 5,908 SF
FIRE-RESISTANCE THROUGH
PENETRATION NOTES
1. THROUGH PENETRATIONS IN FIRE-RESISTANCE-RATED WALLS SHALL BE INSTALLED IN ACCORDANCE WITH
VCC SECTION 714.4.1, EXCEPTION 1:
IN CONCRETE OR MASONRY WALLS WHERE THE PENETRATING ITEM IS A MAXIMUM 6-INCH NOMINAL
DIAMETER AND THE AREA OF THE OPENING THROUGH THE WALL DOES NOT EXCEED 144 SQUARE
INCHES, CONCRETE, GROUT OR MORTAR IS PERMITTED WHERE INSTALLED THE FULL THICKNESS OF THE
WALL OR THE THICKNESS REQUIRED TO MAINTAIN THE FIRE-RESISTANCE RATING.
2. THROUGH PENETRATIONS IN FIRE-RESISTANCE-RATED HORIZONTAL ASSEMBLIES SHALL BE INSTALLED IN
ACCORDANCE WITH VCC SECTION 714.5.1, EXCEPTION 2:
PENETRATIONS IN A SINGLE CONCRETE FLOOR BY STEEL, FERROUS OR COPPER CONDUITS, PIPES, TUBES OR VENTS WITH A MAXIMUM 6-INCH NOMINAL DIAMETER, PROVIDED THAT THE CONCRETE, GROUT OR MORTAR IS INSTALLED THE FULL THICKNESS OF THE FLOOR OR THE THICKNESS REQUIRED TO MAINTAIN THE FIRE-RESISTANCE RATING. THE PENETRATING ITEMS SHALL NOT BE LIMITED TO THE PENETRATION OF A SINGLE CONCRETE FLOOR, PROVIDED THAT THE AREA OF THE OPENING THROUGH EACH FLOOR DOES
NOT EXCEED 144 SQUARE INCHES.
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
G0.02e
Symbols, Materials, Abbreviations, & Project Information
MATERIALSDRAWING SYMBOLS ABBREVIATIONS
# NUMBER
& AND
@ AT
ACP ACOUSTICAL CEILING PANEL
AFF ABOVE FINISH FLOOR
ALT ALTERNATIVE
ALUM ALUMINUM
ASTM AMERICAN SOCIETY OF TESTING &
MATERIALS
BD BUILDING
BOT BOTTOM
CJ CONTROL JOINT
CLG CEILING
CLOS CLOSET
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
CONT CONTINUOUS
CPT CARPET
CT CERAMIC TILE
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DN DOWN
DS DOWNSPOUT
EF EXHAUST FAN
EIFS EXTERIOR INSULATION FINISHING SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EXIST EXISTING
EXT EXTERIOR
FE FIRE EXTINGUISHER
FRT FIRE RETARDANT TREATED
FT FEET/FOOT
GA GAUGE
GALV GALVANIZED
GWB GYPSUM WALL BOARD
HDWR HARDWARE
HM HOLLOW METAL
HR HOUR
IN INCH
INSUL INSULATION
INT INTERIOR
JAN JANITOR'S CLOSET
JT JOINT
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MO MASONRY OPENING
MTL METAL
N NORTH
NIC NOT IN CONTRACT
NO NUMBER
OC ON CENTER
PLAM PLASTIC LAMINATE
PLUMB PLUMBING
PLYWD PLYWOOD
PT PRESSURE TREATED
PTD PAINTED
PVC POLYVINYL CHLORIDE
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RM ROOM
SCW SOLID CORE WOOD
SF SQUARE FOOT/FEET
SIM SIMILAR
SST STAINLESS STEEL
STOR STORAGE
STRUCT STRUCTURAL
THRU THROUGH
TOS TOP OF STEEL
TYP TYPICAL
UL UNDERWRITER'S LABORATORIES
UNO UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITE TILE
VEST VESTIBULE
VIF VERIFY IN FIELD
VWC VINYL WALL COVERING
W/ WITH
WD WOOD
1/32" = 1'-0"A2.01 G0.02e
1 GEOTECHNICAL BORING LOCATIONS
0' 20' 40' 60'
SCALE: 1/32" = 1'-0"
2021 VCC CONCRETE MASONRY WALL THICKNESS
1T
BASE
EXISTING STRUCTURE
ABOVE
ACOUSTICAL SEALANT
4 7/8"
3 5/8" METAL STUDS
@ 24" O.C. MAX
5/8" GYPSUM WALL
BOARD
1 HR PARTITION PER
UL-419.
E
D
7 8 9 104a 6
STORAGE
MATERIAL
LIFTEXIST 2-HOUR
OVERHEAD
CEILING DOOR
CONSTRUCTION
BARRIER
TEMPORARY WAREHOUSE EGRESS
DURING CONSTRUCTION.
TEMPORARILY OPEN AND DISABLE
OVERHEAD DOOR FOR TEMP
EGRESS
EXISTING CANOPY
EXISTING FENCE
AREA OF
CONSTRUCTION
D
N 1 HOUR TEMPORARY
EXTERIOR WALL PER
ESR 174845 MIN TEMPORARY
DOOR. PROVIDE EXIT
SIGNAGE
TEMPORARY MANUF ADA
COMPLIANT ALUM STAIR
TEMPORARILY CLOSE
EXTERIOR DOOR AND
RELOCATE EXIT SIGNAGE
TO TEMP. EGRESS
45 MIN
TEMPORARY
DOOR
1 HOUR TEMPORARY
CONSTRUCTION BARRIER
AT BASEMENT AND SUB-
BASEMENT
1 HOUR TEMPORARY
CONSTRUCTION BARRIER
AT EACH FLOOR
1T1T 1T
REMOVE DOCK LEVELER
AND INFILL WITH TEMP
FLOORING & DELEGATED
DESIGN LIGHT GAUGE MTL
STRUCTURE
G0.03eG0.03e
6a
G
3b 4a 6
EXPANSION JOINT
FREIGHT
ELEVATOR
1 HOUR TEMPORARY
CONSTRUCTION
BARRIER AT EACH
FLOOR
45 MIN
TEMPORARY
DOOR
1T
1T
1T
1T
6b
6c
6a
TEMPORARY MANUF ADA
COMPLIANT ALUM STAIR &
LANDING - DELEGATED
DESIGN
LIGHT GAUGE MTL FRAMING @ 12" OC
45 MIN. TEMP HM DOOR &
FRAME
PRECAST CONC STRUCTURAL
FLOOR PANEL FLUSH WITH EXIST
WAREHOUSE FLOOR
EXTRUDED ALUM ADA COMPLIANT
THRESHOLD SET IN SEALANT
ALUM FLASHING
6" MTL STUD
EXIST. STL ANGLE
4" EIFS
AIR BARRIER
5/8" TYPE X GYPSUM BD
LIGHT GAUGE MTL FRAMING
LEDGER BEYOND, ALL SIDES
4" EIFS
AIR BARRIER
5/8" TYPE X GYPSUM BD
ALUM FLASHING
6" MTL STUD
4" EIFS
AIR BARRIER
5/8" TYPE X GYPSUM BD
R-19 BATT INSULATION
5/8" TYPE X GYPSUM BD
R-19 BATT INSULATION
5/8" TYPE X GYPSUM BD
4" MAX
" R
IS
ER
M
AX
" H
AN
D
RA
IL
" G
U
AR
D
'-0
12" HANDRAIL EXTENSION
11" TREAD MIN 12" HANDRAIL EXT
TEMPORARY MANUF ADA
COMPLIANT ALUM STAIR &
LANDING - DELEGATED
DESIGN
THE FACILITY MANUFACTURES PRODUCTS SUCH AS MATTRESSES AND OTHER
TEXTILE GOODS FOR THE VIRGINIA INDUSTRIES FOR THE BLIND AND THE
MAJORITY OF THE EMPLOYEES ARE VISUALLY IMPAIRED. THE CONTRACTOR
SHALL NOT LEAVE TOOLS, EQUIPMENT OR MATERIALS IN ANY LOCATION
WHERE THEY COULD CAUSE A HAZARD.
THE BUILDING SHALL REMAIN OCCUPIED AND OPERATIONAL THROUGHOUT
CONSTRUCTION. THE SPRINKLER AND FIRE ALARM SYSTEMS MUST REMAIN
OPERATIONAL AT ALL TIMES.
THE CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTING, MAINTAINING,
REMOVING ALL CONSTRUCTION BARRIERS. ALL FINISHES MUST BE REPAIRED
TO THEIR PRE-CONSTRUCTION CONDITION AT THE CONCLUSION OF THE
WORK.
THE CONTRACTOR SHALL SCHEDULE ALL WORK WITH THE OWNER. GENERAL
PHASING OF THE WORK SHALL OF THE WORK SHALL BE AS FOLLOWS:
PHASE 1: CONSTRUCT TEMPORARY BARRIERS FOR REMOVAL OF EXISTING
LIFT BETWEEN SUB-BASEMENT AND BASEMENT AND THE CONSTRUCTION OF
NEW FRIGHT ELEVATOR. CONSTRUCT TEMPORARY EXIT AT LOADING DOCK.
PHASE 2: CONSTRUCT NEW FREIGHT ELEVATOR AND COMMISSION AND
INFILL SLAB AT REMOVED MATERIAL LIFT. NOTE, THE NEW FRIGHT ELEVATOR
MUST BE FULLY OPERATIONAL PRIOR TO PROCEEDING TO THE NEXT PHASE.
PHASE 3: REMOVE TEMPORARY CONSTRUCTION BARRIERS, STAIRS AND
EXISTING WAREHOUSE EGRESS.
PHASE 4: CONSTRUCT TEMPORARY CONSTRUCTION BARRIERS AT EXISTING
FRIGHT ELEVATOR
PHASE 5: REMOVE EXISTING FREIGHT ELEVATOR AND EQUIPMENT.
PHASE 6: INFILL EXISTING SLAB OPENING.
PHASE 7: REMOVE TEMPORARY CONSTRUCTION BARRIERS AND RESTORE ALL
FINISHES TO PRE-CONSTRUCTION CONDITION.
CONSTRUCTION PHASING NOTES
1/8" = 1'-0"A2.01 G0.03e
2 TEMPORARY EGRESS AND CONSTRUCTION BARRIER PLAN
1/8" = 1'-0"A2.01 G0.03e
1 TEMP CONSTRUCTION BARRIER PLAN LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
G0.03e
Temporary Construction Details
5'0' 10' 20'
SCALE: 1/8" = 1'-0"
N
1 1/2" = 1'-0"G0.03e G0.03e
3 TEMP DOOR THRESHOLD DETAIL
TEMPORARY CONSTRUCTION NOTES
1. CONTRACTOR SHALL REMOVE THE EXISTING DOCK LEVELER, BUMPERS, AND OVERHEAD DOOR FROM
LOADING DOCK BAY 1 IN ORDER TO CONSTRUCT THE TEMPORARY EGRESS.
2. THE CONSTRACTOR SHALL INSTALL A 1-HR EXTERIOR TEMPORARY WALL IN ACCORDANCE TO
ESR-1748 AND PROVIDE A TEMPORARY STAIR FOR EGRESS.
3. AT THE CONCLUSION OF CONSTRUCTION AND AFTER EXISTING EGRESS IS RESTORED THE
CONTRACTOR SHALL INSTALL A NEW DOCK LEVELER, BUMPERS, AND OVERHEAD DOOR IN LOADING DOCK
BAY 1.
1/2" = 1'-0"G0.03e G0.03e
4 LOADING DOCK TEMP EGRESS STAIR
X XX X X
X X
X
X X
X XX
1-HR FIRE BARRIER
EGRESS STARTING POINT
POINT AT WHICH A CHOICE OF
TWO EXITS BECOMES AVAILABLE
REMAINING TRAVEL DISTANCE
(REMAINING TRAVEL DISTANCE +
COMMON PATH OF TRAVEL
<250' FOR "S", AND "F-1" OCCUPANCIES
<300' FOR "B" OCCUPANCY).
COMMON PATH OF TRAVEL
<100' FOR "B", "F", AND "S" OCCUPANCIES)
EGRESS LEGEND
2-HR FIRE BARRIER
NOTE: EGRESS SHOWN POST-CONSTRUCTION
SB01
STORAGE
SB10
ELEV EQUIP
RM
SB11
MECHANICAL
ROOM
SB05
TOILET
ROOM
SB08
JAN
CLOS
SB01A
MAINTENANCE
SHOP
MATERIAL
LIFT
SB09
ELEV
LOBBY
S2
STAIR
S3
STAIR
ELEV
FREIGHT
ELEVATOR
18'
72'
45'
30'
29'-4"
56'
UP
UP
UP
STORAGE
ELEC
ROOM
MECHANICAL
RM
WMN'S
TLT
MEN'S
TLT
JAN
CLOS
STORAGE
WAREHOUSE
OFFICE
LIFT
UP
DN UP
S1
STAIR
S3
STAIR
S2
STAIR
FREIGHT
ELEVATOR
ELEV
57'-6"
57'-7"
137'-11"
6' 103'-1"
95'-3" 36'
ELEV
LOBBY
91'-8"
22'-3"
95'99'-9"
8'-6" 10'-4"
DN
MANUFACTURING
AREA
SUPERVISOR
OFFICE
ELEV
LOBBY
WMN'S
TLT
MEN'S
TLT
JAN
CLOS
S1
STAIR
S2
STAIR
S3
STAIR
UPDN
UP
DN UP
OFFICE 131
OFFICE
OFFICE
OFFICE
COPY
ROOM
ROOM
CONFERENCE
RM
WAITING
OFFICE
TOILET
CLOSET
OFFICE
JANITOR
KITCHEN
W TLT
M-TLT 116
BREAK
ROOM
NETWORK
CLOS
ELEC
RM
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
VESTIBULE 233 GSF
136 A
CORRIDOR
FREIGHT
ELEVATOR
ELEV
137'-2"
6'
95'-2" 36'
60'-4"
9'-9"
61'-2"
21'-10"
67'-5"
UP
DN
EXISTING
ROOF
EXISTING
CANOPY
OCCUPANCY LEGEND
FUNCTION OF SPACE OCC. LOAD FACTOR
ASSEMBLY AREAS,
UNCONCENTRATED
15 NSF
PER 2021 VCC TABLE 1004.5
BUSINESS AREAS 150 GSF
ACCESSORY STORAGE AREAS &
MECHANICAL EQUIPMENT ROOM
300 GSF
500 GSFWAREHOUSES
100 GSFINDUSTRIAL
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
G1.01e
Egress, Occupancy & Fire Resistance Rating Plan
OCCUPANCY AND PLUMBING FIXTURE CALCULATIONS
1/16" = 1'-0"A2.01 G1.01e
1 SUB-BASEMENT FLOOR EGRESS PLAN
1/16" = 1'-0"A2.01 G1.01e
2 BASEMENT FLOOR EGRESS PLAN
1/16" = 1'-0"A2.01 G1.01e
3 FIRST FLOOR EGRESS PLAN
0' 10' 20' 30'
SCALE: 1/16" = 1'-0"
N
1-HR FIRE BARRIER
EGRESS STARTING POINT
POINT AT WHICH A CHOICE OF
TWO EXITS BECOMES AVAILABLE
REMAINING TRAVEL DISTANCE
(REMAINING TRAVEL DISTANCE +
COMMON PATH OF TRAVEL
<250' FOR "S", AND "F-1" OCCUPANCIES
<300' FOR "B" OCCUPANCY).
COMMON PATH OF TRAVEL
<100' FOR "B", "F", AND "S" OCCUPANCIES)
EGRESS LEGEND
2-HR FIRE BARRIER
NOTE: EGRESS SHOWN POST-CONSTRUCTION
OCCUPANCY LEGEND
FUNCTION OF SPACE OCC. LOAD FACTOR
ASSEMBLY AREAS,
UNCONCENTRATED
15 NSF
PER 2021 VCC TABLE 1004.5
BUSINESS AREAS 150 GSF
ACCESSORY STORAGE AREAS &
MECHANICAL EQUIPMENT ROOM
300 GSF
500 GSFWAREHOUSES
ASSEMBLY AREAS,
STANDING
5 NSF
100 GSFINDUSTRIAL
VEST
PRODUCTION
UPDN
UP
DN UP
DN
129'-4"
37'-8"
WMN'S
TLT
JAN
CLOS
MEN'S
TLT
ELEV
LOBBY
ELEV
FREIGHT
ELEVATOR
S1
STAIR
STAIR
#3
STAIR
#2
303 A
OFFICE
EXISTING
ROOF
EXISTING
ROOF
DN
54'-7"
4'-6"
65'-8"
EXISTING
ROOF
STORAGE
PENTHOUSE
EXISTING
ROOF
EXISTING
ROOF
EXISTING
ROOF
EXISTING
ROOF FREIGHT
ELEVATOR
WMN'S
TLT
JAN
CLOS
MEN'S
TLT
UPDN
UP
DN UP
TICK
PRODUCTION
VEST
PRODUCTION
ELEV
LOBBY
ELEV
FREIGHT
ELEVATOR
S1
STAIR
S2
STAIR
S3
STAIR
128'-10"
3'-8" 74'-8" 45'-6"
DN
EXISTING
ROOF
EXISTING
ROOF
EXISTING
ROOF
THE FACILITY MANUFACTURES PRODUCTS SUCH AS MATTRESSES AND OTHER
TEXTILE GOODS FOR THE VIRGINIA INDUSTRIES FOR THE BLIND AND THE
MAJORITY OF THE EMPLOYEES ARE VISUALLY IMPAIRED. THE CONTRACTOR
SHALL NOT LEAVE TOOLS, EQUIPMENT OR MATERIALS IN ANY LOCATION
WHERE THEY COULD CAUSE A HAZARD.
THE BUILDING SHALL REMAIN OCCUPIED AND OPERATIONAL THROUGHOUT
CONSTRUCTION. THE SPRINKLER AND FIRE ALARM SYSTEMS MUST REMAIN
OPERATIONAL AT ALL TIMES.
THE CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTING, MAINTAINING,
REMOVING ALL CONSTRUCTION BARRIERS. ALL FINISHES MUST BE REPAIRED
TO THEIR PRE-CONSTRUCTION CONDITION AT THE CONCLUSION OF THE
WORK.
THE CONTRACTOR SHALL SCHEDULE ALL WORK WITH THE OWNER. GENERAL
PHASING OF THE WORK SHALL OF THE WORK SHALL BE AS FOLLOWS:
PHASE 1: CONSTRUCT TEMPORARY BARRIERS FOR REMOVAL OF EXISTING
LIFT BETWEEN SUB-BASEMENT AND BASEMENT AND THE CONSTRUCTION OF
NEW FRIGHT ELEVATOR. CONSTRUCT TEMPORARY EXIT AT LOADING DOCK.
PHASE 2: CONSTRUCT NEW FREIGHT ELEVATOR AND COMMISSION AND
INFILL SLAB AT REMOVED MATERIAL LIFT. NOTE, THE NEW FRIGHT ELEVATOR
MUST BE FULLY OPERATIONAL PRIOR TO PROCEEDING TO THE NEXT PHASE.
PHASE 3: REMOVE TEMPORARY CONSTRUCTION BARRIERS, STAIRS AND
EXISTING WAREHOUSE EGRESS.
PHASE 4: CONSTRUCT TEMPORARY CONSTRUCTION BARRIERS AT EXISTING
FRIGHT ELEVATOR
PHASE 5: REMOVE EXISTING FREIGHT ELEVATOR AND EQUIPMENT.
PHASE 6: INFILL EXISTING SLAB OPENING.
PHASE 7: REMOVE TEMPORARY CONSTRUCTION BARRIERS AND RESTORE ALL
FINISHES TO PRE-CONSTRUCTION CONDITION.
CONSTRUCTION PHASING NOTES
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
G1.02e
Egress, Occupancy and Fire Resistance Rating Plan
1/16" = 1'-0"A2.01 G1.02e
2 THIRD FLOOR EGRESS PLAN
1/16" = 1'-0"A2.01 G1.02e
3 ROOF EGRESS PLAN
1/16" = 1'-0"A2.01 G1.02e
1 SECOND FLOOR EGRESS PLAN
0' 10' 20' 30'
SCALE: 1/16" = 1'-0"
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
G2.01e
UL Details
UL DESIGN D916
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
G2.02e
UL Details
UL DESIGN D916, CONTINUED
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
G2.03e
UL Details
UL DESIGN P801
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
G2.04e
UL Details
UL DESIGN F-A-1218
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
G2.05e
UL Details
ESR 1748
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
G2.06e
UL Details
ESR 1748
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
G2.07e
Boring Logs
18" RCP
" R
CP
18" RCP
" R
CP
15" RCP
6" PVC 6" PVC 6" PVC
6" PVC
6" PIPE
6" PIPE
6" PIPE
4" PVC
6" PIPE
4"
PIP
E
4" PIPE
VI
RG
IN
IA
S
TA
TE
G
RI
D
NO
RT
H
NA
D
E:11490600 N:3896000
E:11490600 N:3895800
E:11491000 N:3896000
E:11491000 N:3896200
M O
NT
IC
EL
LO
R O
AD
BRAINBRIDGE STREET
LE
O
NA
RD
S
TR
EE
T
EXISTING BUILDING
1102 Monticello Road
EX. FF = 472.48
EX. BF = 463.32
464 46
466 46
478480
PROPOSED ELEVATOR
" R
CP
18" RCP
" R
CP
REMOVE PORTION OF
EXISTING 18" STORM
SEWER
X X X X X X X
TOP=468.25
INV OUT = 462.87
TOP=468.26
INV IN = 462.58
INV OUT = 462.48
TOP=466.90
INV IN = 461.87
INV OUT = 461.77
TOP=467.17
INV IN = 461.46
INV OUT = 461.36
68.32 67.54
67.39 68.08
A
B
C
CLEANOUT
TOP=467.06
INV = 460.00
CLEANOUT
TOP=467.12
INV = 459.76
CLEANOUT
TOP=464.43
INV = 459.16
INV IN = 458.75
8" HDPE
8" HDPE
8" HDPE
PROP. 8" HDPE PIPE
SYSTEM TO CONNECT
ELEVATOR FOUNDATION
DRAIN TO EX. STORM
SEWER
10 402020 0
GRAPHIC SCALE
1" = 20'
04/18/2026
C400e
SITE PLAN
Consultants
703.684.5994
333 North Fairfax Street Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902 une 10, 2026
22017.03
No. Revision Date
06/10/2026
J
C401e
DETAILS
Consultants
703.684.5994
333 North Fairfax Street Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902 une 10, 2026
22017.03
No. Revision Date
06/10/2026
J
X X
X
SD
SD
7 8
G
STORAGE
D-5
D-4
FREIGHT
ELEVATOR
3b 4a
D-3
D-6
EXPANSION JOINT
MATERIAL
LIFT2-HOUR
OVERHEAD
CEILING DOOR
AD3.01eAD1.01e
AD3.01eAD1.01e
AD3.01eAD1.01e
AD3.01eAD1.01e
D-8
D-7
EQ
VIF
14'-8" EQ
7 8 9
G
D-5
D-4
3b 4a
D-6
WAREHOUSE ROOF
FREIGHT
ELEVATOR
EXPANSION JOINT
AD3.01eAD1.01e
AD3.01eAD1.01e
D-4
AD3.01eAD1.01e
D-7
EQ
VIF
14'-8" EQ
7 8 9
G
SB01A
MAINTENANCE
SHOP
SB01
STORAGE
MATERIAL
LIFT
D-1
X X
X
4a 6
X X
D-3
AD3.01eAD1.01e
EXIST FENCE
TO REMAIN
D-2
AD3.01eAD1.01e
EXIST FENCE
TO REMAIN
EQ
VIF
14'-8" EQ
G
VEST
PRODUCTION
3b 4a 6
D-6
EXPANSION JOINT
OFFICE
D-4
D-5
AD3.01eAD1.01e
AD3.01eAD1.01e
D-4
FREIGHT
ELEVATOR
AD3.01eAD1.01e
EQ
VIF
14'-8" EQ
7 8 9
G
3b 4a 6
EXPANSION JOINT
STORAGE
MOP
WINDING
D-6
D-5
AD3.01eAD1.01e
AD3.01eAD1.01e
D-4
FREIGHT
ELEVATOR
D-4
AD3.01eAD1.01e
EQ
VIF
14'-8" EQ
N
AREA OF WORK
F
8 9
G
OPEN TO
BELOW
PENTHOUSE
3b 4a 6
AD3.01eAD1.01e
D-9
EQ
VIF
14'-8" EQ
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
AD1.01e
Partial Demolition Floor Plans
1/8" = 1'-0"A2.01 AD1.01e
2 PARTIAL BASEMENT DEMOLITION PLAN
GENERAL DEMOLITION NOTES
1. ALL EXISTING DIMENSIONS AND CONDITIONS SHALL BE FIELD VERIFIED.
2. REQUIRED DEMOLITION SHALL NOT BE LIMITED TO THAT PORTION ON THE
PLANS, BUT SHALL INCLUDE ALL NECESSARY WORK (OR INCIDENTAL THERE TO)
TO COMPLETE THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
3. REMOVE FLOOR, WALL, AND CEILING FINISHES AND CONSTRUCTION AS
INDICATED.
4. REPAIR EXISTING CONSTRUCTION TO REMAIN WHERE MECHANICAL, PLUMBING,
FIRE PROTECTION, AND ELECTRICAL WORK IS REMOVED TO MATCH EXISTING
CONSTRUCTION. WHERE MASONRY IS EXPOSED, TOOTH-IN NEW WORK WITH
FULL-SIZE MASONRY UNITS.
5. PREPARE REMAINING SPACE TO RECEIVE NEW CONSTRUCTION. PATCH ALL AREAS
INCLUDING BUT NOT LIMITED TO ROOFS, WALLS, FLOORING, AND SLABS. ALL
PATCH WORK TO MATCH EXISTING.
5'0' 10' 20'
SCALE: 1/8" = 1'-0"
N
1/8" = 1'-0"A2.01 AD1.01e
3 PARTIAL FIRST FLOOR DEMOLITION PLAN
1/8" = 1'-0"A2.01 AD1.01e
1 PARTIAL SUB BASEMENT DEMOLITION FLOOR PLAN
1/8" = 1'-0"A2.01 AD1.01e
4 PARTIAL SECOND FLOOR DEMOLITION PLAN
1/8" = 1'-0"A2.01 AD1.01e
5 PARTIAL THIRD FLOOR DEMOLITION PLAN
KEY DEMOLITION NOTES
1/8" = 1'-0"A2.01 AD1.01e
6 PARTIAL ROOF DEMOLITION PLAN
D-1 EXCAVATE AND REMOVE PORTION OF EXISTING FOUNDATION WALL TO
ACCOMODATE NEW ELEVATOR - SHORE - SEE STRUCT
D-2 REMOVE EXISTING CHAIN LINK FENCE & GATE
D-3 REMOVE EXISTING MATERIAL LIFT - SEE ELEC
D-4 REMOVE EXISTING MASONRY ELEVATOR ELEVATOR SHAFT WALL - SHORE -
SEE STRUCT
D-5 REMOVE EXISTING WINDOW AND EXTERIOR WALL. CONSISTING OF EIFS
AND BRICK - SHORE - SEE STRUCT
D-6 REMOVE ALL EXISTING FREIGHT ELEVATOR COMPONENTS, INCLUDUNG BUT
NOT LIMITED TO CAB, RAILS, PISTON, HOIST BEAM, CALL BUTTONS, AND
DOORS.
D-7 SHORE & UNDERPIN CANOPY FOUNDATION, SEE STRUCT
D-9 REMOVE ROOFING, FASCIA, & BLOCKING DOWN TO STRUCTURAL DECK
FIRST FLOOR
483' - 5 3/4"
SECOND FLOOR
494' - 5 3/4"
THIRD FLOOR
505' - 2 3/4"
TOP OF EXIST ROOF SLAB
519' - 8 3/4"
BASEMENT
472' - 5 3/4"
SUB-BASEMENT
463' - 3 3/4"
H G
PENTHOUSE ROOF
529' - 8 3/4"
AD3.01eAD1.01e
REMOVE FREIGHT
ELEVATOR SHAFT
REMOVE FREIGHT
ELEVATOR SHAFT
REMOVE FREIGHT
ELEVATOR SHAFT
REMOVE FREIGHT ELEVATOR
SHAFT, EQUIPMENT, AND
COMPONENTS
ROOF ACCESS LADDER
PENTHOUSE
REMOVE
HOIST BEAM
FIRST FLOOR
483' - 5 3/4"
SECOND FLOOR
494' - 5 3/4"
THIRD FLOOR
505' - 2 3/4"
TOP OF EXIST ROOF SLAB
519' - 8 3/4"
BASEMENT
472' - 5 3/4"
SUB-BASEMENT
463' - 3 3/4"
4 5
PENTHOUSE ROOF
529' - 8 3/4"
3b 4a
AD3.01eAD1.01e
REMOVE FREIGHT ELEVATOR
SHAFT WALLS, TYP
PENTHOUSE
EXIST CONCRETE BEAM
EXIST LOAD BEARING
MASONRY WALL
REMOVE ALL FREIGHT ELEVATOR
EQUIPMENT AND COMPONENTS
INCLUDING DOORS, JAMBS,
CABS, AND RAILS, TYP
EXIST CONCRETE BEAM
EXIST LOAD BEARING
MASONRY WALL
EXIST CONCRETE BEAM
EXIST LOAD BEARING
MASONRY WALL
EXIST CONCRETE BEAM
EXIST LOAD BEARING
MASONRY WALL
FREIGHT
ELEVATOR
REMOVE
MASONRY
REMOVE EXIST ELEVATOR
EQUIPMENT
ABANDON JACK COLLAR
AND PATCH HOLE
FIRST FLOOR
483' - 5 3/4"
SECOND FLOOR
494' - 5 3/4"
THIRD FLOOR
505' - 2 3/4"
TOP OF EXIST ROOF SLAB
519' - 8 3/4"
BASEMENT
472' - 5 3/4"
SUB-BASEMENT
463' - 3 3/4"
CONC ELEV PIT
459' - 5 3/4"
REMOVE
FOUNDATION WALL -
SHORE - SEE STRUCT
REMOVE MASONRY
WALL - SHORE - SEE
STRUCT
REMOVE WINDOW
REMOVE MASONRY
WALL - SHORE - SEE
STRUCT
REMOVE WINDOW
REMOVE MASONRY
WALL BELOW
WINDOW - SHORE -
SEE STRUCT
REMOVE WINDOW
REMOVE MASONRY
WALL BELOW
WINDOW - SHORE -
SEE STRUCT
REMOVE WINDOW
REMOVE COPING &
PARAPET. MAINTAIN
BUILDING IN A WATER
TIGHT CONDITION
THROUGH
CONSTRUCTION
REMOVE EIFS
REMOVE EIFS
REMOVE EIFS
REMOVE EIFS
REMOVE PORTION
OF FOOTING - SEE
STRUCT
REMOVE PAVING AND
EXCAVATE - SEE CIVIL
REMOVE MASONRY -
SHORE - SEE STRUCT
SIM.
BASEMENT
472' - 5 3/4"
SUB-BASEMENT
463' - 3 3/4"
REMOVE LIFT AND
ALL ASSCOCIATED
EQUIPMENT
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
AD3.01e
Demolition Floor Sections
1/4" = 1'-0"AD1.01e AD3.01e
1 DEMO EXIST ELEVATOR NORTH SECTION
1/4" = 1'-0"AD1.01e AD3.01e
2 DEMO EXIST ELEVATOR EAST SECTION
1/4" = 1'-0"AD1.01e AD3.01e
3 DEMOLITION EXTERIOR WALL SECTION
1/4" = 1'-0"AD1.01e AD3.01e
MATERIAL LIFT
DEMOLITION SECTION
X X
X
X
7 8 9
H
G
SB01
STORAGE
CHAIN LINK
FENCE
4a
E2
FRIEGHT
ELEVATOR
A1.01e A4.01e
A2.01eA1.01e
A2.01eA1.01e
A2.01eA1.01e
SB10
ELEV EQUIP
RM
SB10A
FREIGHT ELEV
EQUIP RM
A1.02e
Sim
SB01A
MAINTENANCE
SHOP
A
'-0
2'-10" 6'-4" 3'-5 5/8"
INFILL CONCRETE
FLOOR - SEE STRUCT
A3.01eA1.01e
LOCKABLE
GATE WITH
FREE EGRESS
EQ
VIF
14'-8" EQ
'-0
/8
4 3/8"
'-0
1'-0" 1'-0"
4 3/8"
A1.01e A3.01e
7 8 9 10
H
G
STORAGE
ELEC
ROOM
UP
3b 4a
EXPANSION
JOINT
E2
FREIGHT
ELEVATOR
A2.01eA1.01e
A2.01eA1.01e
A2.01eA1.01e
A1.02e
Sim
PRIME & PAINT
CONCRETE FLOOR
INFILL - SEE STRUCT
INFILL CONCRETE
FLOOR - SEE STRUCT
A1.01e A4.01e
A3.01eA1.01e
A3.01eA1.01e
A3.01eA1.01e
CONDENSERS
ON MFGR'S
STAND - SEE
MECH
EXIST FENCE
ENCLOUSURE
EXIST
COOLING
TOWER
EQ
VIF
14'-8" EQ
BALLARDS
7 8 9
H
G
3b 4a 6
EXPANSION
JOINT
E2
FRIEGHT
ELEVATOR
A2.01eA1.01e
A2.01eA1.01e
A2.01eA1.01e
A1.01e A1.02e
A3.01eA1.01e
A3.01eA1.01e
A1.02e
RESTORE CANOPY -
SEE 2/G0.02e
EQ
VIF
14'-8" EQ
'-0
PRIME & PAINT
CONCRETE FLOOR
INFILL - SEE STRUCT
'-0
8" CMU
PRECAST BOND
BEAM LINTEL - SEE
STRUCT
HM FRAME
CONTINUOUS PERIMETER
SEALANT, EA SIDE
HM DOOR
HM FRAME BEYOND
2 1/2"
HM FRAME
MASONRY ANCHORS -
3 PER JAMB
HM DOOR
CONTINUOUS PERIMETER
SEALANT EACH SIDE
8" CMU
HM DOOR
HM FRAME BEYOND
A1.01e5 /
A1.01e4 /
A1.01e6 /
2" 6'-0" 2"
'-0
A
8" CMU
RESILIENT BASE ON
BOTH SIDES
EXISTING
STRUCTURE
ABOVE
7 5/8"
N
AREA OF WORK
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
A1.01e
Partial Floor Plans
N
5'0' 10' 20'
SCALE: 1/8" = 1'-0"1/8" = 1'-0"A2.01 A1.01e
1 PARTIAL SUB BASEMENT FLOOR PLAN
1/8" = 1'-0"A2.01 A1.01e
2 PARTIAL BASEMENT FLOOR PLAN
1/8" = 1'-0"A2.01 A1.01e
3 PARTIAL FIRST FLOOR PLAN
1 1/2" = 1'-0"A1.01e
7 PARTITION TYPE
1 1/2" = 1'-0"A1.01e A1.01e
5 JAMB DETAIL
1 1/2" = 1'-0"A1.01e A1.01e
4 HEAD DETAIL
1 1/2" = 1'-0"A1.01e A1.01e
6 THRESHOLD DETAIL
GENERAL NEW CONSTRUCTION NOTES
1. DIMENSIONS ARE TO FINISH FACE OF CONSTRUCTION UNLESS OTHERWISE NOTED.
2. TOOTH IN MASONRY WHERE ALTERING OR REPARING EXISTING MASONRY.
3. PAINTED SURFACES SHALL INCLUDE ENTIRE WALLS TO CORNERS.
4. WHERE EXISTING LIFE & ELEVATOR ACCESSORIES ARE REMOVED, PATCH WITH FULL SIZE MASONRY
UNITS, PRIME & PAINT TO MATCH EXISTING.
5. PRIME AND PAINT EXPOSED INTERIOR SHAFT WALLS TO REMAIN TO MATCH ADJACENT SURFACES.
DOOR TYPES
7 8 9
H
G
VEST
PRODUCTION
3b 4a
EXPANSION
JOINT
E2
FRIEGHT
ELEVATOR
OFFICE
A2.01eA1.01e
A2.01eA1.01e
A2.01eA1.01e
A1.01e A4.01e
A3.01eA1.01e
A3.01eA1.01e
A1.02e
Sim
EQ
VIF
14'-8" EQ
'-0
PRIME & PAINT
CONCRETE FLOOR
INFILL - SEE STRUCT
7 8 9
H
G
STORAGE
3b 4a 6
EXPANSION
JOINT
E2
FREIGHT
ELEVATOR
A2.01eA1.01e
A2.01eA1.01e
A2.01eA1.01e
A1.01e A4.01e
A1.02e
Sim
MOP WINDING
A3.01eA1.01e
A3.01eA1.01e
EQ
VIF
14'-8" EQ
PRIME & PAINT
CONCRETE FLOOR
INFILL - SEE STRUCT
7 8 9
H
G
3b 4a 6
A2.01eA1.01e
A2.01eA1.01e
A2.01eA1.01e
OPEN TO
BELOW
A
ROOF AREA
PENTHOUSE
A1.02e A4.01e
A3.01eA1.01e
A3.01eA1.01e
8 9
3" 10'-0" 3"
3/8" RECTANGULAR WIRE
MESH, SINGLE SECTION
SLIDE UP POWER
OPERATED SS GATE W/
SAFETY EDGE SENSOR
'-0
MASONRY WALL TO MATCH EXIST
PAINT ENTIRE WALL
FREIGHT ELEVATOR
BIPARTING LANDING DOOR
BEYOND
EMER GENCY
ELEVATOR
OPERA TOR
USE
STA IRWAY
I N CASE
OF FIRE
FIRE SVC BYPASS
EMERGENCY INSTRUCTIONS
PLACARD
HALL PUSHBUTTON STATION -
CENTERED 42" AFF BETWEEN
CALL BUTTONS
WA RN IN G
FIRE SVC BYPASS
EMERGENCY INSTRUCTIONS
PLACARD
" O
C
RAISED AND BRAILLE FLOOR
INDICATOR - EA JAMB HALL LANTERN W/
DIRECTIONAL SIGNAL &
POSITION INDICATOR
" O
C
N
AREA OF WORK
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
A1.02e
Partial Floor Plans and Elevator Elevations
1/8" = 1'-0"A2.01 A1.02e
1 PARTIAL SECOND FLOOR PLAN
1/8" = 1'-0"A1.01e A1.02e
2 PARTIAL THIRD FLOOR PLAN
1/8" = 1'-0"A2.01 A1.02e
3 ROOF PLAN
5'0' 10' 20'
SCALE: 1/8" = 1'-0"
1/4" = 1'-0"A1.01e A1.02e
5 ELEVATION ELEVATOR GATE
N
EXISTING ROOFING
TO REMAIN
1. DIMENSIONS ARE TO FINISH FACE OF CONSTRUCTION UNLESS OTHERWISE NOTED.
2. TOOTH IN MASONRY WHERE ALTERING OR REPARING EXISTING MASONRY.
3. PAINTED SURFACES SHALL INCLUDE ENTIRE WALLS TO CORNERS.
4. WHERE EXISTING LIFE & ELEVATOR ACCESSORIES ARE REMOVED, PATCH WITH FULL SIZE MASONRY
UNITS, PRIME & PAINT TO MATCH EXISTING.
5. PRIME AND PAINT EXPOSED INTERIOR SHAFT WALLS TO REMAIN TO MATCH ADJACENT SURFACES.
GENERAL NEW CONSTRUCTION NOTES
SECOND FLOOR
494' - 5 3/4"
THIRD FLOOR
505' - 2 3/4"
TOP OF EXIST ROOF SLAB
519' - 8 3/4"
BASEMENT
472' - 5 3/4"
SUB-BASEMENT
463' - 3 3/4"
A4.01eA2.01e
EIFS
EXISTING WINDOW -
TYP
CONC FOUNDATION -
SEE STRUCT
MANUFACTURED
METAL COPING
CONC FOUNDATION -
SEE STRUCT
ASPHALT PAVING
EXISTING EIFS -
TYP
CONC ELEV PIT
459' - 5 3/4"
TOP OF MASONRY
524' - 4 3/4"
CONDENSERS ON
MFR'S STAND-
SEE MECH
RELIEF LOUVER -
SEE MECH
2'-0" 11'-10" 2'-0"
LAMBS TOUNGE
DRAINAGE W/
INSECT SCREEN
PC SPLASH
BLOCK
BOLLARDS
A2.01e A4.02e
A4.02eA2.01e
FIRST FLOOR
483' - 5 3/4"
SECOND FLOOR
494' - 5 3/4"
THIRD FLOOR
505' - 2 3/4"
TOP OF EXIST ROOF SLAB
519' - 8 3/4"
BASEMENT
472' - 5 3/4"
SUB-BASEMENT
463' - 3 3/4"
A4.01eA2.01e
4" EIFS, R-16 MIN.
CONC FOUNDATION - SEE
STRUCT
CONC FOUNDATION -
SEE STRUCT
ASPHALT PAVING
CONC ELEV PIT
459' - 5 3/4"
TOP OF MASONRY
524' - 4 3/4"
MANUFACTURED
METAL COPING
2'-0" 11'-9 7/8" 2'-0"
6" EIFS, R-20 MIN.
A4.02eA2.01e
FIRST FLOOR
483' - 5 3/4"
SECOND FLOOR
494' - 5 3/4"
THIRD FLOOR
505' - 2 3/4"
TOP OF EXIST ROOF SLAB
519' - 8 3/4"
BASEMENT
472' - 5 3/4"
SUB-BASEMENT
463' - 3 3/4"
A4.01eA2.01e
MANUFACTURED
METAL COPING
ASPHALT PAVING
CONC FOUNDATION -
SEE STRUCT
CONC ELEV PIT
459' - 5 3/4"
TOP OF MASONRY
524' - 4 3/4"
CONC FOUNDATION -
SEE STRUCT
2'-0" 11'-9 7/8" 2'-0"
4" EIFS, R-16 MIN.
6" EIFS, R-20 MIN.
PC SPLASH BLOCK
LAMBS TOUNGE SUMP
DISHCHARGE W/ INSECT SCREEN
A4.02eA2.01e
AREA OF WORK
N
1/4" = 1'-0"A1.01e A2.01e
3 ELEVATION ELEVATOR EAST
1/4" = 1'-0"A1.01e A2.01e
1 ELEVATION ELEVATOR NORTH
1/4" = 1'-0"A1.01e A2.01e
2 ELEVATION ELEVATOR WEST
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
A2.01e
Freight Elevator Elevations
0' 1' 2' 4'6"
SCALE: 1/2" = 1'-0"
SECOND FLOOR
494' - 5 3/4"
THIRD FLOOR
505' - 2 3/4"
TOP OF EXIST ROOF SLAB
519' - 8 3/4"
BASEMENT
472' - 5 3/4"
SUB-BASEMENT
463' - 3 3/4"
PENTHOUSE ROOF
529' - 8 3/4"
3b 4a
A3.01eA1.01e
PRIME & PAINT
2HR CONCRETE
FLOOR PER UL
D-916 - SEE STRUCT
PRIME & PAINT
2HR CONCRETE
FLOOR PER UL
D-916 - SEE STRUCT
PRIME & PAINT
2HR CONCRETE
FLOOR PER UL
D-916 - SEE STRUCT
EXIST CONCRETE BEAM
EXIST LOAD BEARING
MASONRY WALL
EXIST CONCRETE BEAM
EXIST LOAD BEARING
MASONRY WALL
EXIST CONCRETE BEAM
EXIST LOAD BEARING
MASONRY WALL
EXIST CONCRETE BEAM
EXIST LOAD BEARING
MASONRY WALL
PRIME & PAINT
2HR CONCRETE
FLOOR - SEE STRUCT
VAPOR BARRIER
STONE
HG
A3.01eA1.01e
PRIME & PAINT
2HR CONCRETE
FLOOR PER UL
D-916 - SEE STRUCT
PRIME & PAINT
2HR CONCRETE
FLOOR PER UL
D-916 - SEE STRUCT
PRIME & PAINT
2HR CONCRETE
FLOOR PER UL
D-916 - SEE STRUCT
PRIME & PAINT
2HR CONCRETE
FLOOR - SEE STRUCT
ROOF ACCESS LADDER
VAPOR BARRIER
STONE
BASEMENT
472' - 5 3/4"
SUB-BASEMENT
463' - 3 3/4"
CONC ELEV PIT
459' - 5 3/4"
PRIME & PAINT
2HR CONCRETE
FLOOR PER UL
D-916 - SEE STRUCT
PRIME & PAINT
2HR CONCRETE
FLOOR - SEE STRUCT
AC-2 HYDRAULIC
PUMP
CONTROLLER
PANEL "N"
ELEV CAB LIGHT DISC.
ELEV CAB COMM DISC.
MDP DISC.
T
1/4" = 1'-0"A1.01e A3.01e
2 ELEVATOR INFILL EAST SECTION
1/4" = 1'-0"A1.01e A3.01e
3 ELEVATOR INFILL NORTH SECTION
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
A3.01e
Elevator Infill Sections
1/4" = 1'-0"A1.01e A3.01e
1 LIFT INFILL NORTH SECTION
1/2" = 1'-0"A1.01e A3.01e
4 ENLARGED ELEV MACHINE RM
A4.01eA2.01e
A4.01eA2.01e
CAST IN PLACE CONC
FOUNDATION WALL
CONC UNDERPINNING - SEE
STRUCT
EXIST CONC FOUNDATION
WALL
SUMP PUMP & OIL
MINDER - SEE PLUMB
ELEVATOR GUIDE RAIL
CYLINDER & PISTON
ELEVATOR PIT LADDER
ELEVATOR CAB
FOOTPRINT
CAST IN PLACE CONC
FOOTING BELOW - SEE
STRUCT
1'-0" 15'-5 1/8" 1'-0"
'-0
14'-8"
FACE OF CMU ABOVE,
TYP
1'-0" TYP
SUMP DISCHARGE
PIPING - SEE PLUMB
FIRST FLOOR
483' - 5 3/4"
SECOND FLOOR
494' - 5 3/4"
THIRD FLOOR
505' - 2 3/4"
TOP OF EXIST ROOF SLAB
519' - 8 3/4"
BASEMENT
472' - 5 3/4"
SUB-BASEMENT
463' - 3 3/4"
8 9
A4.01eA2.01e
VAPOR BARRIER
8" CMU
METAL ROOF DECK - 1 HR
SPRAY FIRE PROOFING
ROOFING MEMBRANE
TAPERED RIGID INSULATION
MFR MTL COPING
ASPHALT PAVING
COMPACTED STONE
COMPACTED EARTH
FOUNDATION WATER
PROOFING
DRAINAGE BOARD
FOUNDATION
DRAIN - SEE CIVIL
VAPOR BARRIER
CONC ELEV PIT
459' - 5 3/4"
TOP OF MASONRY
524' - 4 3/4"
A4.01e A4.02e
A4.01e A4.02e
SIM. SIM.
A2.01e A4.02e
FREIGHT
ELEVATOR
CAB
HOIST BEAM - SEE STRUCT
EXHAUST FAN
ELEVATOR OVERRUN,
VERIFY WITH FREIGHT
ELEVATOR MFR
EXTEND CANOPY FOOTING AND
EXTEND ELEVATOR FOOTOING,
SEE STRUCT
EXIST CANOPY COLUMN
CYLINDER & PISTON
ELEVATOR GUIDE RAIL
STORM SEWER - SEE CIVIL
STORM SEWER -
SEE CIVIL
6" EIFS, R-24 MIN
4" EIFS, R-16 MIN
15'-0"
FOUNDATION DRAIN - SEE
CIVIL
EIFS PILASTER BEYOND
LAMBS TOUNGE DRAINAGE
W/ INSECT SCREEN
PC SPLASH BLOCK
A4.01e A4.02e
A4.01e A4.02e
FIRST FLOOR
483' - 5 3/4"
SECOND FLOOR
494' - 5 3/4"
THIRD FLOOR
505' - 2 3/4"
TOP OF EXIST ROOF SLAB
519' - 8 3/4"
BASEMENT
472' - 5 3/4"
SUB-BASEMENT
463' - 3 3/4"
A4.01eA2.01e
ROOFING MEMBRANE
TAPERED RIGID INSULATION
EXIST PIER FOUNDATION
EXIST FOUNDATION
UNDERPINNING - SEE STRUCT
CONC ELEV PIT
459' - 5 3/4"
TOP OF MASONRY
524' - 4 3/4"
A4.01e A4.03e
A4.01e A4.03e
A4.01e A4.02e
A4.01e A4.02e
FREIGHT
ELEVATOR
CAB
A4.01e ---
SUMP - SEE PLUMB
VAPOR BARRIER
FOUNDATION WATER
PROOFING
SCUPPER & SPLASH BLOCK
ELEVATOR OVERRUN,
VERIFY WITH FREIGHT
ELEVATOR MFR
8" CMU
4" EIFS,
R-16 MIN
ELEVATOR GUIDE RAIL
BIPARTING LANDING DOOR
ELEVATOR PIT LADDER
CYLINDER & PISTON
EXHAUST FAN
METAL ROOF DECK - 1 HR SPRAY
FIRE PROOFING
HOIST BEAM - SEE STRUCT
MFR MTL
COPING
3/8" RECTANGULAR WIRE
MESH SINGLE SECTION
SLIDE UP POWER OPERATED
SS GATE W/ SAFETY EDGE
SENSOR
STORM SEWER -
SEE CIVIL
'-0
'-3
C
EL
AR
'-2
C
LE
AR
'-0
C
LE
AR
'-0
C
LE
AR
'-0
A4.01e A4.03e
A4.01e A4.03e
C
LE
AR
'-0
'-0
'-6
'-9
'-0
'-0
'-9
'-5
'-1
16'-2"
6" EIFS,
R-24 MIN
VAPOR
BARRIER
'-0
"2'-0"
FOUNDATION DRAIN
TO ELEVATOR SUMP
SUMP DRAINAGE
PIPING - SEE PLUMB
1/2"/1FT CRICKET
1/2"/1FT CRICKET
8 9
A4.01eA2.01e
A4.01eA2.01e
A2.01eA1.01e 3
A2.01eA1.01e
A2.01eA1.01e
SCUPPER & 4"x4"
DOWNSPOUT
MFR MTL COPING
1/2"/FT CRICKET, TYP
FULLY ADHERED ROOFING
MEMBRANE OVER TAPERED
INSULATION
CONC SPLASH BLOCK
EXHAUST FAN - SEE
MECH
/4
F T S
LO
P E
1'-4"
WALL MOUNTED TIE-
OFF ANCHOR, TYP
EXIST CANOPY
BELOW
EXIST PARAPET EXIST PARAPET
EQ EQ
1/2"/FT CRICKET, TYP
A4.02eA4.01e
8 9
A4.01eA2.01e
A4.01eA2.01e
A2.01eA1.01e
A2.01eA1.01e
4" EIFS, R-16 MIN.
8" CMU
A4.01e A4.02e
FREIGHT
ELEVATOR
CAB
EXIST EIFS
7" 14'-8" 7"
ELEVATOR GUIDE RAIL
'-0
2'-0" 2'-0"
'-0
'-0
'-0
1'-0" 2'-4"
CLEAR
10'-0" 2'-4" 1'-0"
FACE OF EIFS
BELOW, TYP0"
6" EIFS, R-20 MIN.
2HR FIRE BARRIER
2"
N
AREA OF WORK
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
A4.01e
Enlarged Freight Elevator Plans and Sections
0' 1' 2' 4'6"
SCALE: 1/2" = 1'-0"1/4" = 1'-0"A1.01e A4.01e
4 ELEVATOR PIT FLOOR PLAN
1/4" = 1'-0"A2.01e A4.01e
5 SHAFT SECTION
1/4" = 1'-0"A2.01e A4.01e
6 SHAFT SECTION
1/4" = 1'-0"A1.02e A4.01e
1 ELEVATOR ROOF PLAN
1/4" = 1'-0"A1.01e A4.01e
2 ENLARGED ELEVATOR PLAN TYP
N
N
TOP OF EXIST ROOF SLAB
519' - 8 3/4"
TOP OF MASONRY
524' - 4 3/4"
MFR MTL COPING
TERMINATION BAR & SEALANT
TAPERED RIGID
INSULATION
METAL ROOF
DECK 1 HR
SPRAY FIRE
PROOFING
THRU WALL SCUPPER
ROOFING
MEMBRANE
TAPERED RIGID INSULATION
MEMBRANE ROOFING
EXIST CONC BEAM
MEMBRANE PROTECTION LAYER
MTL RECEIVER &
COUNTERFLASHING
ALUM SCUPPER
CONDUCTOR HEAD
4" X 4" ALUM
DOWNSPOUT
BOND BEAM -
SEE STRUCT
1/2" GYPSUM BD
3 5/8" METAL STUD
ELEV DOOR FRAME
CONC SPLASH BLOCK
8" 8
4" EIFS, R-16 MIN
PRECAST CONC LINTEL - SEE STRUCT
1"
AIR BARRIER
STEEL ANGLE -
1 HR SPRAY
FIRE PROOFING,
SEE STRUCT
EXIST MASONRY BEYOND
TOP OF MASONRY
524' - 4 3/4"
METAL ROOF DECK -1 HR SPRAY FIRE PROOFING
TAPERED RIGID INSULATION
PARAPET BEYOND
CMU, SEE STRUCT
DRIP EDGE
WD
BLOCKING MEMBRANE ROOFING
MEMBRANE FLASHING
MFR MTL COPING
MFR CONTINUOUS
ATTACHMENT CLEAT
BOND BEAM, SEE STRUCT
'-0
'-6
2" 7 5/8"
'-3
AIR BARRIER
EIFS PILASTER
BEYOND
DRIP EDGE
STEEL ANGLE 1 HR SPRAY FIRE PROOFING,SEE STRUCT
2"
6" EIFS, R-20 MIN.
ELEVATOR
GUIDE RAIL
7 5/8"
ALIGN W/ EXIST FIRST
FLOOR WINDOW SILL
4"
4" EIFS, R-16 MIN.
AIR BARRIER
EIFS PILASTER
BEYOND
BOND BEAM -
SEE STRUCT
V
IF
'-3
/8
6"
EIFS
EXIST EIFS
EXIST BRICK
MASONRY
CONC INFILL
ELEV DOOR FRAME
BY ELEV MFR
ELEV DOOR
BACKER ROD & SEALANT
/8
1/2" GYPSUM BD
AIR BARRIER
3 5/8" MTL STUD @ 16"
OC MAX
REPLACE BRICK TO MATCH EXIST &
PAINT ENTIRE WALL- SEE FINISH
SCHEDULE
V
IF
V
AR
RI
ES
'-0
'-2
7" 6" 7"
'-6
CONCRETE FILL-
ROUND TOP &
PAINT
6" STL PIPE
BOLLARD FILLED
W/ CONC & PAINT
CONC FOOTING -
SEE STRUCT
ASPHALT PAVING
MFR FAN CURB
RIGID INSULATION
ROOFING MEMBRANE
WELDED SEAM
MEMBRANE FLASHING
EXHAUST FAN
MTL DECK 1 HR
SPRAY FIRE
PROOFING
STEEL ANGLE - 1
HR SPRAY FIRE
PROOFING, SEE
STRUCT
SUB-BASEMENT
463' - 3 3/4"
CONC ELEV PIT
459' - 5 3/4"
ASPHALT
PAVING
FLUID
APPLIED
VAPOR
BARRIER
FOUNDATION
DRAIN
DRAINAGE
BOARD
VAPOR BARRIER
FOUNDATION
WATER
PROOFING
END
TERMINATION
DRIP EDGE
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
LAE
WN
O M
M O
OF
I
NI
G
RI
H V
E C TCRA
LOUIS M.
BARBIERI JR.
Lic. No. 16266
T
C
A
IH T
Consultants
703.684.5994
333 North Fairfax Street
Alexandria, Virginia 22314
Seal
Key Plan
Drawing
Revisions
Date
Project No.
Sheet No.
Bid Submission 6/10/2026
Submission Set coleanddenny.com
Permit Electronic Approval Stamp
Renovate the VIB Facility in Charlottesville Freight Elevator Addition P.C. No.:702-18581-002
1102 Monticello Road Charlottesville, VA 22902
06/10/26
June 10, 2026
22017.03
A4.02e
Enlarged Freight Elevator Details
1 1/2" = 1'-0"A4.01e A4.02e
1 ELEVATOR PARAPET DETAIL
1 1/2" = 1'-0"A4.01e A4.02e
2 ELEVATOR PARAPET DETAIL
1" = 1'-0"A2.01e A4.02e
4 EIFS DETAIL
1 1/2" = 1'-0"A4.01e A4.02e
3 ELEVATOR JAMB DETAIL
0' 1' 2'6"
SCALE: 1 1/2" = 1'-0"
0' 6" 1' 2'
SCALE: 1" = 1'-0"
3/4" = 1'-0"A2.01e A4.02e
5 BOLLARD DETAIL
1" = 1'-0"A4.01e A4.02e
6 MECH CURB EQUIP DETAIL
1/2" = 1'-0"A4.01e A4.02e
7 FOUNDATION DTL
THIRD FLOOR
505' - 2 3/4"
EXISTING
CONC BEAM
ELEV HM DOOR
CONC SLAB
EXTENSION
CMU
PRECAST LINTEL
METAL STUDS
1/2" GYPSUM BD
ELEV DOOR FRAME
BY ELEV MFR
ELEV DOOR FRAME
BY ELEV MFR
SEE STRUCT FOR BOND
BEAM LOCATIONS, TYP.
SECOND FLOOR
494' - 5 3/4"
EXISTING
CONC BEAM
METAL STUDS
1/2" GYPSUM BD
ELEV DOOR FRAME
BY ELEV MFR
ELEV DOOR FRAME
BY ELEV MFR
"ELEV HM DOOR
PRECAST LINTEL
CONC SLAB
EXTENSION
SEE STRUCT FOR
BOND BEAM
LOCATIONS, TYP.
BASEMENT
472' - 5 3/4"
EXISTING
CONC BEAM
CONC SLAB
EXTENSION
PRECAST LINTEL
ELEV DOOR FRAME
BY ELEV MFR
ELEV DOOR FRAME
BY ELEV MFR
ELEV HM DOOR
This is the start of the file's text. The full file is on GovTribe.