This is a technical drawings document for the Kenosha County Detention Center Building Envelope Project located at 4777 88th Avenue, Kenosha, Wisconsin 53144. The project encompasses roof replacement and building envelope improvements across six distinct roof sections of the detention center facility. The drawings, prepared by The Garland Company (Cleveland, Ohio), present specifications for two roofing system options: adhered EPDM (ethylene propylene diene monomer) membrane systems for Sections 1-6 and modified bitumen roof systems for the same sections, allowing bidders to propose either system type. Common work across all sections includes removal of existing ballasted EPDM roofing systems down to the insulation surface, removal and replacement of wet insulation as identified by infrared scanning, installation of mechanical and adhered PolyISO insulation layers (varying between 1 inch to 1.5 inches of high-density material plus 5 inches of standard insulation), installation of roof membranes with complete flashing systems, installation of new cast iron drains with tapered sumps, replacement of sheet metal perimeter details, and installation of elastomeric-coated walkways at five-foot widths in designated areas. All roof penetrations must maintain minimum eight-inch flashing heights, and contractors are required to provide tapered insulation drawings for approval and schedule any interior exposure work with 48-hour advance notice to the owner.
The drawings include comprehensive detail sheets addressing specific roof conditions and penetrations, including inside corners, curb flashings, membrane splices, pipe penetrations, pitch pockets, raised metal edges, heat stacks, roof drains, parapet flashings, and metal counter flashings. Contractors are required to manage all electrical, plumbing, and HVAC disconnections and reconnections, while lightning protection systems must be detached and reattached by a licensed third-party contractor. The document emphasizes that roof fields must be uniform with positive water flow to drains, and roof sections vary slightly in existing insulation depths (5 inches for Sections 1-2 and 6.5 inches for Sections 3-6). Detail requirements specify that one-piece sheet metal fascia is limited to eight inches maximum, with any extensions requiring two-piece metal and keeper strips. The project file includes 13 pages of technical drawings with multiple detail sheets referenced throughout the specifications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Vendor Responsibility Form Construction.pdf | ||
| 2605 Specifications.pdf | ||
| 2605 Addendum 1.pdf | ||
| 2605 Bid Documents.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ISSUED:
K E
N O
S H
A C
O U
N T
Y
D e te n ti o n C e n te r
B u ild in g E n v e lo p e P ro je c t th A v e
K e n o s h a W
I
SHEET NO.
The Garland Company
3800 E. 91 st
Street
Cleveland, OH 44105
SHEET TITLE:
THE INFORMATION CONTAINED HEREIN IS OF
A PROPRIETARY NATURE AND IS SUBMITTED
IN CONFIDENCE FOR USE BY THE CLIENTS
APPROVED BY THE ORIGINATOR OF THIS
DOCUMENT - ONLY. THE USE OF THESE
DOCUMENTS FOR ANY OTHER PROJECTS,
PURPOSE, LOCATION, PUBLICATION,
REPRODUCTION OR DISTRIBUTION IN WHOLE
OR PART, BY ANY INDIVIDUAL OR
ORGANIZATION WITHOUT WRITTEN
PERMISSION THE ORIGINATING COMPANY IS
PROHIBITED. THE INFORMATION HEREIN
REMAINS THE PROPERTY AND ITS USE OR
DISCLOSURE TO OTHERS IS PROHIBITED FOR
ANY USE NOT AUTHORIZED BY THE
ORIGINATING COMPANY.
12/31/2025
COVER
PAGE
DETENTION CENTER BUILDING
ENVELOPE PROJECT
Project No: #2605
COMMUNICATIONS
BUILDING
C-1
ROOF SECTION 1
ROOF SECTION 2
ROOF SECTION 3
ROOF SECTION 4
ROOF SECTION 5ROOF SECTION 6
E
N O
S H
A C
O U
N T
Y
D e te n ti o n C e n te r
B u ild in g E n v e lo p e P ro je c t th A v e
K e n o s h a W
I
SHEET NO.
The Garland Company
3800 E. 91 st
Street
Cleveland, OH 44105
SHEET TITLE:
THE INFORMATION CONTAINED HEREIN IS OF
A PROPRIETARY NATURE AND IS SUBMITTED
IN CONFIDENCE FOR USE BY THE CLIENTS
APPROVED BY THE ORIGINATOR OF THIS
DOCUMENT - ONLY. THE USE OF THESE
DOCUMENTS FOR ANY OTHER PROJECTS,
PURPOSE, LOCATION, PUBLICATION,
REPRODUCTION OR DISTRIBUTION IN WHOLE
OR PART, BY ANY INDIVIDUAL OR
ORGANIZATION WITHOUT WRITTEN
PERMISSION THE ORIGINATING COMPANY IS
PROHIBITED. THE INFORMATION HEREIN
REMAINS THE PROPERTY AND ITS USE OR
DISCLOSURE TO OTHERS IS PROHIBITED FOR
ANY USE NOT AUTHORIZED BY THE
ORIGINATING COMPANY.
12/31/2025
ROOF SECTION
1 & 2 - EPDM
KCDC – Roof Section 1 & 2 – Adhered EPDM Roof Systems
Roof Preparation & Installation
1. Remove Existing Roof System down to Insulation Surface.
2. Remove wet insulation per IR Scan and replace with matching. Sweep clean surface of insulation of all dirt and debris.
3. Mechanically attach 1 – 1" layer of PolyISO insulation to Metal Deck
4. Install 1 – 1/2” Layer of High Density PolyISO insulation, adhered in insulation adhesive
5. Install 60 Mil Adhered EPDM for Field and Flashings, fully adhered
6. Install New 24ga Sheet Metal to Perimeters, Flashings, Counter Flashings, Coping Caps, etc
7. Install new cast iron drains, taper into roof with 8' x 8' sumps
8. Install Elastomeric Coated Walkways in Denoted areas, at 5' widths
EXISTING ROOF MAKEUP
• Ballasted EPDM
• 5" PolyISO Insulation
• Gypsum Board
• Metal Deck
NEW ROOF MAKEUP
• Adhered EPDM
• ½” HD PolyISO
• 1” PolyISO
• 5" PolyISO Insulation
• Gypsum Board
• Metal Deck
Project Notes
1. All roof penetrations shall have a min. of 8" flashing heights.
2. Field of roof is to be uniform and will ensure positive water flow to roof drains.
3. Contractor to provide tapered insulation drawings for approval. Crickets to be installed at Corners, Curbs, Etc, as Required.
4. All Electrical, Plumbing, and HVAC Disconnect/Reconnects shall be provided by the
“Contractor”.
5. Lightning Protection to be detached and reattached, by a licensed 3rd party Lightning
Protection contractor.
6. Any work being done at the roof deck level or an area with exposed interior, must get approval by owner and must be scheduled 48 hours in advance.
Expansion Joint
Equipment Support
Roof Curb
Roof Drain
Pitch Pocket
Plumbing Stack
Roof Hatch
Penetration Box
Remove Penetration
Walkway
Throughwall Scupper
Insulation Slope
Insulation Cricket
Heat Stack
Roof Section 1
Roof Section 2
A-1
D1
D1
D1
D1
D1
D1
D1
D2
D2
D1
D1
E
N O
S H
A C
O U
N T
Y
D e te n ti o n C e n te r
B u ild in g E n v e lo p e P ro je c t th A v e
K e n o s h a W
I
SHEET NO.
The Garland Company
3800 E. 91 st
Street
Cleveland, OH 44105
SHEET TITLE:
THE INFORMATION CONTAINED HEREIN IS OF
A PROPRIETARY NATURE AND IS SUBMITTED
IN CONFIDENCE FOR USE BY THE CLIENTS
APPROVED BY THE ORIGINATOR OF THIS
DOCUMENT - ONLY. THE USE OF THESE
DOCUMENTS FOR ANY OTHER PROJECTS,
PURPOSE, LOCATION, PUBLICATION,
REPRODUCTION OR DISTRIBUTION IN WHOLE
OR PART, BY ANY INDIVIDUAL OR
ORGANIZATION WITHOUT WRITTEN
PERMISSION THE ORIGINATING COMPANY IS
PROHIBITED. THE INFORMATION HEREIN
REMAINS THE PROPERTY AND ITS USE OR
DISCLOSURE TO OTHERS IS PROHIBITED FOR
ANY USE NOT AUTHORIZED BY THE
ORIGINATING COMPANY.
12/31/2025
KCDC – Roof Section 3 & 4 – Adhered EPDM Roof Systems
Roof Preparation & Installation
1. Remove Existing Roof System down to Insulation Surface.
2. Remove wet insulation per IR Scan and replace with matching. Sweep clean surface of insulation of all dirt and debris.
3. Mechanically attach 1 – 1" layer of PolyISO insulation to Metal Deck
4. Install 1 – 1/2” Layer of High Density PolyISO insulation, adhered in insulation adhesive
5. Install 60 Mil Adhered EPDM for Field and Flashings, fully adhered
6. Install New 24ga Sheet Metal to Perimeters, Flashings, Counter Flashings, Coping Caps, etc
7. Install new cast iron drains, taper into roof with 8' x 8' sumps
8. Install Elastomeric Coated Walkways in Denoted areas, at 5' widths
EXISTING ROOF MAKEUP
• Ballasted EPDM
• 6.5" PolyISO Insulation
• Gypsum Board
• Metal Deck
NEW ROOF MAKEUP
• Adhered EPDM
• ½” HD PolyISO
• 1” PolyISO
• 5" PolyISO Insulation
• Gypsum Board
• Metal Deck
Project Notes
1. All roof penetrations shall have a min. of 8" flashing heights.
2. Field of roof is to be uniform and will ensure positive water flow to roof drains.
3. Contractor to provide tapered insulation drawings for approval. Crickets to be installed at Corners, Curbs, Etc, as Required.
4. All Electrical, Plumbing, and HVAC Disconnect/Reconnects shall be provided by the
“Contractor”.
5. Lightning Protection to be detached and reattached, by a licensed 3rd party Lightning
Protection contractor.
6. Any work being done at the roof deck level or an area with exposed interior, must get approval by owner and must be scheduled 48 hours in advance.
Expansion Joint
Equipment Support
Roof Curb
Roof Drain
Pitch Pocket
Plumbing Stack
Roof Hatch
Penetration Box
Remove Penetration
Walkway
Throughwall Scupper
Insulation Slope
Insulation Cricket
Heat Stack
Roof Section 3
Roof Section 4
ROOF SECTION
3 & 4 - EPDM
A-2
D1
D1
D2
D2
D1
D1
D1
D1
D1
D1
E
N O
S H
A C
O U
N T
Y
D e te n ti o n C e n te r
B u ild in g E n v e lo p e P ro je c t th A v e
K e n o s h a W
I
SHEET NO.
The Garland Company
3800 E. 91 st
Street
Cleveland, OH 44105
SHEET TITLE:
THE INFORMATION CONTAINED HEREIN IS OF
A PROPRIETARY NATURE AND IS SUBMITTED
IN CONFIDENCE FOR USE BY THE CLIENTS
APPROVED BY THE ORIGINATOR OF THIS
DOCUMENT - ONLY. THE USE OF THESE
DOCUMENTS FOR ANY OTHER PROJECTS,
PURPOSE, LOCATION, PUBLICATION,
REPRODUCTION OR DISTRIBUTION IN WHOLE
OR PART, BY ANY INDIVIDUAL OR
ORGANIZATION WITHOUT WRITTEN
PERMISSION THE ORIGINATING COMPANY IS
PROHIBITED. THE INFORMATION HEREIN
REMAINS THE PROPERTY AND ITS USE OR
DISCLOSURE TO OTHERS IS PROHIBITED FOR
ANY USE NOT AUTHORIZED BY THE
ORIGINATING COMPANY.
12/31/2025
KCDC – Roof Section 5 – Adhered EPDM Roof Systems
Roof Preparation & Installation
1. Remove Existing Roof System down to Insulation Surface.
2. Remove wet insulation per IR Scan and replace with matching. Sweep clean surface of insulation of all dirt and debris.
3. Mechanically attach 1 – 1" layer of PolyISO insulation to Metal Deck
4. Install 1 – 1/2” Layer of High Density PolyISO insulation, adhered in insulation adhesive
5. Install 60 Mil Adhered EPDM for Field and Flashings, fully adhered
6. Install New 24ga Sheet Metal to Perimeters, Flashings, Counter Flashings, Coping Caps, etc
7. Install new cast iron drains, taper into roof with 8' x 8' sump
8. Install Elastomeric Coated Walkways in Denoted areas, at 5' widths
EXISTING ROOF MAKEUP
• Ballasted EPDM
• 6.5" PolyISO Insulation
• Gypsum Board
• Metal Deck
NEW ROOF MAKEUP
• Adhered EPDM
• ½” HD PolyISO
• 1” PolyISO
• 5" PolyISO Insulation
• Gypsum Board
• Metal Deck
Project Notes
1. All roof penetrations shall have a min. of 8" flashing heights.
2. Field of roof is to be uniform and will ensure positive water flow to roof drains.
3. Contractor to provide tapered insulation drawings for approval. Crickets to be installed at Corners, Curbs, Etc, as Required.
4. All Electrical, Plumbing, and HVAC Disconnect/Reconnects shall be provided by the
“Contractor”.
5. Lightning Protection to be detached and reattached, by a licensed 3rd party Lightning
Protection contractor.
6. Any work being done at the roof deck level or an area with exposed interior, must get approval by owner and must be scheduled 48 hours in advance.
Expansion Joint
Equipment Support
Roof Curb
Roof Drain
Pitch Pocket
Plumbing Stack
Roof Hatch
Penetration Box
Remove Penetration
Raise Curb
Throughwall Scupper
Insulation Slope
Insulation Cricket
Heat Stack
Roof Section 5
ROOF SECTION
5 - EPDM
A-3
D2
D2
D1
D1
E
N O
S H
A C
O U
N T
Y
D e te n ti o n C e n te r
B u ild in g E n v e lo p e P ro je c t th A v e
K e n o s h a W
I
SHEET NO.
The Garland Company
3800 E. 91 st
Street
Cleveland, OH 44105
SHEET TITLE:
THE INFORMATION CONTAINED HEREIN IS OF
A PROPRIETARY NATURE AND IS SUBMITTED
IN CONFIDENCE FOR USE BY THE CLIENTS
APPROVED BY THE ORIGINATOR OF THIS
DOCUMENT - ONLY. THE USE OF THESE
DOCUMENTS FOR ANY OTHER PROJECTS,
PURPOSE, LOCATION, PUBLICATION,
REPRODUCTION OR DISTRIBUTION IN WHOLE
OR PART, BY ANY INDIVIDUAL OR
ORGANIZATION WITHOUT WRITTEN
PERMISSION THE ORIGINATING COMPANY IS
PROHIBITED. THE INFORMATION HEREIN
REMAINS THE PROPERTY AND ITS USE OR
DISCLOSURE TO OTHERS IS PROHIBITED FOR
ANY USE NOT AUTHORIZED BY THE
ORIGINATING COMPANY.
12/31/2025
KCDC – Roof Section 6 – Adhered EPDM Roof Systems
Roof Preparation & Installation
1. Remove Existing Roof System down to Insulation Surface.
2. Remove wet insulation per IR Scan and replace with matching. Sweep clean surface of insulation of all dirt and debris.
3. Mechanically attach 1 – 1" layer of PolyISO insulation to Metal Deck
4. Install 1 – 1/2” Layer of High Density PolyISO insulation, adhered in insulation adhesive
5. Install 60 Mil Adhered EPDM for Field and Flashings, fully adhered
6. Install New 24ga Sheet Metal to Perimeters, Flashings, Counter Flashings, Coping Caps, etc
7. Install new cast iron drains, taper into roof with 8' x 8' sumps
8. Install Elastomeric Coated Walkways in Denoted areas, at 5' widths
EXISTING ROOF MAKEUP
• Ballasted EPDM
• 6.5" PolyISO Insulation
• Gypsum Board
• Metal Deck
NEW ROOF MAKEUP
• Adhered EPDM
• ½” HD PolyISO
• 1” PolyISO
• 5" PolyISO Insulation
• Gypsum Board
• Metal Deck
Project Notes
1. All roof penetrations shall have a min. of 8" flashing heights.
2. Field of roof is to be uniform and will ensure positive water flow to roof drains.
3. Contractor to provide tapered insulation drawings for approval. Crickets to be installed at Corners, Curbs, Etc, as Required.
4. All Electrical, Plumbing, and HVAC Disconnect/Reconnects shall be provided by the
“Contractor”.
5. Lightning Protection to be detached and reattached, by a licensed 3rd party Lightning
Protection contractor.
6. Any work being done at the roof deck level or an area with exposed interior, must get approval by owner and must be scheduled 48 hours in advance.
Expansion Joint
Equipment Support
Roof Curb
Roof Drain
Pitch Pocket
Plumbing Stack
Roof Hatch
Penetration Box
Remove Penetration
Raise Curb
Throughwall Scupper
Insulation Slope
Insulation Cricket
Heat Stack
Roof Section 6
ROOF SECTION
6 - EPDM
A-4
D2
D1
D2
D1
E
N O
S H
A C
O U
N T
Y
D e te n ti o n C e n te r
B u ild in g E n v e lo p e P ro je c t th A v e
K e n o s h a W
I
SHEET NO.
The Garland Company
3800 E. 91 st
Street
Cleveland, OH 44105
SHEET TITLE:
THE INFORMATION CONTAINED HEREIN IS OF
A PROPRIETARY NATURE AND IS SUBMITTED
IN CONFIDENCE FOR USE BY THE CLIENTS
APPROVED BY THE ORIGINATOR OF THIS
DOCUMENT - ONLY. THE USE OF THESE
DOCUMENTS FOR ANY OTHER PROJECTS,
PURPOSE, LOCATION, PUBLICATION,
REPRODUCTION OR DISTRIBUTION IN WHOLE
OR PART, BY ANY INDIVIDUAL OR
ORGANIZATION WITHOUT WRITTEN
PERMISSION THE ORIGINATING COMPANY IS
PROHIBITED. THE INFORMATION HEREIN
REMAINS THE PROPERTY AND ITS USE OR
DISCLOSURE TO OTHERS IS PROHIBITED FOR
ANY USE NOT AUTHORIZED BY THE
ORIGINATING COMPANY.
12/31/2025
KCDC – Roof Section 1 & 2 – Modified Bitumen Roof
Systems
Roof Preparation & Installation
1. Remove Existing Roof System down to Insulation Surface
2. Remove wet insulation per IR Scan and replace with matching. Sweep clean surface of insulation of all dirt and debris.
3. Mechanically attach 1 - 1" layer of PolyISO insulation to Metal Deck
4. Install Wood Fiber Recovery Board in Hot Asphalt
5. Install (1) One Layer of Modified Base Sheet to Field and Flashings, in Hot Asphalt
6. Install (1) One Layer of Smooth Surface Modified Cap Sheet to Field and (1) One Layer of Mineral Surface Cap Sheet to Flashings, in Hot Asphalt
7. Install Flood and Gravel Surface in Hot Asphalt
8. Install New 24ga Sheet Metal to Perimeters, Flashings, Counter Flashings, Coping Caps, etc
9. Install cast iron drains, taper into roof with 8' x 8' sumps
EXISTING ROOF MAKEUP
• Ballasted EPDM
• 5" PolyISO Insulation
• Gypsum Board
• Metal Deck
NEW ROOF MAKEUP
• Flood and Gravel Surface
• Modified Bitumen Roof
• Woodfiber Recovery Board
• 1" PolyISO
• 5" PolyISO Insulation
• Gypsum Board
• Metal Deck
Project Notes
1. All roof penetrations shall have a min. of 8" flashing heights.
2. Field of roof is to be uniform and will ensure positive water flow to roof drains.
3. Contractor to provide tapered insulation drawings for approval. Crickets to be installed at Corners, Curbs, Etc, as Required.
4. All Electrical, Plumbing, and HVAC Disconnect/Reconnects shall be provided by the
“Contractor”.
5. Lightning Protection to be detached and reattached, by a licensed 3rd party Lightning
Protection contractor.
6. Any work being done at the roof deck level or an area with exposed interior, must get approval by owner and must be scheduled 48 hours in advance.
Expansion Joint
Equipment Support
Roof Curb
Roof Drain
Pitch Pocket
Plumbing Stack
Roof Hatch
Penetration Box
Remove Penetration
Raise Curb
Throughwall Scupper
Insulation Slope
Insulation Cricket
Heat Stack
Roof Section 1
Roof Section 2
ROOF SECTION
1 & 2 – MOD BIT
A-5
D4
D4
D4
D4
D4
D4
D4
D4
D4
D4
E
N O
S H
A C
O U
N T
Y
D e te n ti o n C e n te r
B u ild in g E n v e lo p e P ro je c t th A v e
K e n o s h a W
I
SHEET NO.
The Garland Company
3800 E. 91 st
Street
Cleveland, OH 44105
SHEET TITLE:
THE INFORMATION CONTAINED HEREIN IS OF
A PROPRIETARY NATURE AND IS SUBMITTED
IN CONFIDENCE FOR USE BY THE CLIENTS
APPROVED BY THE ORIGINATOR OF THIS
DOCUMENT - ONLY. THE USE OF THESE
DOCUMENTS FOR ANY OTHER PROJECTS,
PURPOSE, LOCATION, PUBLICATION,
REPRODUCTION OR DISTRIBUTION IN WHOLE
OR PART, BY ANY INDIVIDUAL OR
ORGANIZATION WITHOUT WRITTEN
PERMISSION THE ORIGINATING COMPANY IS
PROHIBITED. THE INFORMATION HEREIN
REMAINS THE PROPERTY AND ITS USE OR
DISCLOSURE TO OTHERS IS PROHIBITED FOR
ANY USE NOT AUTHORIZED BY THE
ORIGINATING COMPANY.
12/31/2025
KCDC – Roof Section 3 & 4 – Modified Bitumen Roof
Systems
Roof Preparation & Installation
1. Remove Existing Roof System down to Insulation Surface
2. Remove wet insulation per IR Scan and replace with matching. Sweep clean surface of insulation of all dirt and debris.
3. Mechanically attach 1 - 1" layer of PolyISO insulation to Metal Deck
4. Install Wood Fiber Recovery Board in Hot Asphalt
5. Install (1) One Layer of Modified Base Sheet to Field and Flashings, in Hot Asphalt
6. Install (1) One Layer of Smooth Surface Modified Cap Sheet to Field and (1) One Layer of Mineral Surface Cap Sheet to Flashings, in Hot Asphalt
7. Install Flood and Gravel Surface in Hot Asphalt
8. Install New 24ga Sheet Metal to Perimeters, Flashings, Counter Flashings, Coping Caps, etc
9. Install cast iron drains, taper into roof with 8' x 8' sumps
EXISTING ROOF MAKEUP
• Ballasted EPDM
• 6.5" PolyISO Insulation
• Gypsum Board
• Metal Deck
NEW ROOF MAKEUP
• Flood and Gravel Surface
• Modified Bitumen Roof
• Woodfiber Recovery Board
• 1" PolyISO
• 5" PolyISO Insulation
• Gypsum Board
• Metal Deck
Project Notes
1. All roof penetrations shall have a min. of 8" flashing heights.
2. Field of roof is to be uniform and will ensure positive water flow to roof drains.
3. Contractor to provide tapered insulation drawings for approval. Crickets to be installed at Corners, Curbs, Etc, as Required.
4. All Electrical, Plumbing, and HVAC Disconnect/Reconnects shall be provided by the
“Contractor”.
5. Lightning Protection to be detached and reattached, by a licensed 3rd party Lightning
Protection contractor.
6. Any work being done at the roof deck level or an area with exposed interior, must get approval by owner and must be scheduled 48 hours in advance.
Expansion Joint
Equipment Support
Roof Curb
Roof Drain
Pitch Pocket
Plumbing Stack
Roof Hatch
Penetration Box
Remove Penetration
Raise Curb
Throughwall Scupper
Insulation Slope
Insulation Cricket
Heat Stack
Roof Section 3
Roof Section 4
ROOF SECTION
3 & 4 – MOD BIT
A-6
D4
D4
D4
D4
D4
D4
D4
D4
D4
D4
D4
KCDC – Roof Section 3 & 4 – Modified Bitumen Roof
Systems
Roof Preparation & Installation
1. Remove Existing Roof System down to Insulation Surface
2. Remove wet insulation per IR Scan and replace with matching. Sweep clean surface of insulation of all dirt and debris.
3. Mechanically attach 1 - 1" layer of PolyISO insulation to Metal Deck
4. Install Wood Fiber Recovery Board in Hot Asphalt
5. Install (1) One Layer of Modified Base Sheet to Field and Flashings, in Hot Asphalt
6. Install (1) One Layer of Smooth Surface Modified Cap Sheet to Field and (1) One Layer of Mineral Surface Cap Sheet to Flashings, in Hot Asphalt
7. Install Flood and Gravel Surface in Hot Asphalt
8. Install New 24ga Sheet Metal to Perimeters, Flashings, Counter Flashings, Coping Caps, etc
9. Install cast iron drains, taper into roof with 8' x 8' sumps
EXISTING ROOF MAKEUP
• Ballasted EPDM
• 6.5" PolyISO Insulation
• Gypsum Board
• Metal Deck
NEW ROOF MAKEUP
• Flood and Gravel Surface
• Modified Bitumen Roof
• Woodfiber Recovery Board
• 1" PolyISO
• 5" PolyISO Insulation
• Gypsum Board
• Metal Deck
Project Notes
1. All roof penetrations shall have a min. of 8" flashing heights.
2. Field of roof is to be uniform and will ensure positive water flow to roof drains.
3. Contractor to provide tapered insulation drawings for approval. Crickets to be installed at Corners, Curbs, Etc, as Required.
4. All Electrical, Plumbing, and HVAC Disconnect/Reconnects shall be provided by the
“Contractor”.
5. Lightning Protection to be detached and reattached, by a licensed 3rd party Lightning
Protection contractor.
6. Any work being done at the roof deck level or an area with exposed interior, must get approval by owner and must be scheduled 48 hours in advance.
Expansion Joint
Equipment Support
Roof Curb
Roof Drain
Pitch Pocket
Plumbing Stack
Roof Hatch
Penetration Box
Remove Penetration
Raise Curb
Throughwall Scupper
Insulation Slope
Insulation Cricket
Heat Stack
Roof Section 3
Roof Section 4
ROOF SECTION
3 & 4 – MOD BIT
A-6
D4
D4
D4
D4
D4
D4
D4
D4
D4
D4
E
N O
S H
A C
O U
N T
Y
D e te n ti o n C e n te r
B u ild in g E n v e lo p e P ro je c t th A v e
K e n o s h a W
I
SHEET NO.
The Garland Company
3800 E. 91 st
Street
Cleveland, OH 44105
SHEET TITLE:
THE INFORMATION CONTAINED HEREIN IS OF
A PROPRIETARY NATURE AND IS SUBMITTED
IN CONFIDENCE FOR USE BY THE CLIENTS
APPROVED BY THE ORIGINATOR OF THIS
DOCUMENT - ONLY. THE USE OF THESE
DOCUMENTS FOR ANY OTHER PROJECTS,
PURPOSE, LOCATION, PUBLICATION,
REPRODUCTION OR DISTRIBUTION IN WHOLE
OR PART, BY ANY INDIVIDUAL OR
ORGANIZATION WITHOUT WRITTEN
PERMISSION THE ORIGINATING COMPANY IS
PROHIBITED. THE INFORMATION HEREIN
REMAINS THE PROPERTY AND ITS USE OR
DISCLOSURE TO OTHERS IS PROHIBITED FOR
ANY USE NOT AUTHORIZED BY THE
ORIGINATING COMPANY.
12/31/2025
KCDC – Roof Section 5 – Modified Bitumen Roof Systems
Roof Preparation & Installation
1. Remove Existing Roof System down to Insulation Surface
2. Remove wet insulation per IR Scan and replace with matching. Sweep clean surface of insulation of all dirt and debris.
3. Mechanically attach 1 - 1" layer of PolyISO insulation to Metal Deck
4. Install Wood Fiber Recovery Board in Hot Asphalt
5. Install (1) One Layer of Modified Base Sheet to Field and Flashings, in Hot Asphalt
6. Install (1) One Layer of Smooth Surface Modified Cap Sheet to Field and (1) One Layer of Mineral Surface Cap Sheet to Flashings, in Hot Asphalt
7. Install Flood and Gravel Surface in Hot Asphalt
8. Install New 24ga Sheet Metal to Perimeters, Flashings, Counter Flashings, Coping Caps, etc
9. Install cast iron drains, taper into roof with 8' x 8' sumps
EXISTING ROOF MAKEUP
• Ballasted EPDM
• 6.5" PolyISO Insulation
• Gypsum Board
• Metal Deck
NEW ROOF MAKEUP
• Flood and Gravel Surface
• Modified Bitumen Roof
• Woodfiber Recovery Board
• 1" PolyISO
• 5" PolyISO Insulation
• Gypsum Board
• Metal Deck
Project Notes
1. All roof penetrations shall have a min. of 8" flashing heights.
2. Field of roof is to be uniform and will ensure positive water flow to roof drains.
3. Contractor to provide tapered insulation drawings for approval. Crickets to be installed at Corners, Curbs, Etc, as Required.
4. All Electrical, Plumbing, and HVAC Disconnect/Reconnects shall be provided by the
“Contractor”.
5. Lightning Protection to be detached and reattached, by a licensed 3rd party Lightning
Protection contractor.
6. Any work being done at the roof deck level or an area with exposed interior, must get approval by owner and must be scheduled 48 hours in advance.
Expansion Joint
Equipment Support
Roof Curb
Roof Drain
Pitch Pocket
Plumbing Stack
Roof Hatch
Penetration Box
Remove Penetration
Raise Curb
Throughwall Scupper
Insulation Slope
Insulation Cricket
Heat Stack
Roof Section 5
ROOF SECTION
5 – MOD BIT
A-7
D4
D4
D4
E
N O
S H
A C
O U
N T
Y
D e te n ti o n C e n te r
B u ild in g E n v e lo p e P ro je c t th A v e
K e n o s h a W
I
SHEET NO.
The Garland Company
3800 E. 91 st
Street
Cleveland, OH 44105
SHEET TITLE:
THE INFORMATION CONTAINED HEREIN IS OF
A PROPRIETARY NATURE AND IS SUBMITTED
IN CONFIDENCE FOR USE BY THE CLIENTS
APPROVED BY THE ORIGINATOR OF THIS
DOCUMENT - ONLY. THE USE OF THESE
DOCUMENTS FOR ANY OTHER PROJECTS,
PURPOSE, LOCATION, PUBLICATION,
REPRODUCTION OR DISTRIBUTION IN WHOLE
OR PART, BY ANY INDIVIDUAL OR
ORGANIZATION WITHOUT WRITTEN
PERMISSION THE ORIGINATING COMPANY IS
PROHIBITED. THE INFORMATION HEREIN
REMAINS THE PROPERTY AND ITS USE OR
DISCLOSURE TO OTHERS IS PROHIBITED FOR
ANY USE NOT AUTHORIZED BY THE
ORIGINATING COMPANY.
12/31/2025
KCDC – Roof Section 6 – Modified Bitumen Roof Systems
Roof Preparation & Installation
1. Remove Existing Roof System down to Insulation Surface
2. Remove wet insulation per IR Scan and replace with matching. Sweep clean surface of insulation of all dirt and debris.
3. Mechanically attach 1 - 1" layer of PolyISO insulation to Metal Deck
4. Install Wood Fiber Recovery Board in Hot Asphalt
5. Install (1) One Layer of Modified Base Sheet to Field and Flashings, in Hot Asphalt
6. Install (1) One Layer of Smooth Surface Modified Cap Sheet to Field and (1) One Layer of Mineral Surface Cap Sheet to Flashings, in Hot Asphalt
7. Install Flood and Gravel Surface in Hot Asphalt
8. Install New 24ga Sheet Metal to Perimeters, Flashings, Counter Flashings, Coping Caps, etc
9. Install cast iron drains, taper into roof with 8' x 8' sumps
EXISTING ROOF MAKEUP
• Ballasted EPDM
• 6.5" PolyISO Insulation
• Gypsum Board
• Metal Deck
NEW ROOF MAKEUP
• Flood and Gravel Surface
• Modified Bitumen Roof
• Woodfiber Recovery Board
• 1" PolyISO
• 5" PolyISO Insulation
• Gypsum Board
• Metal Deck
Project Notes
1. All roof penetrations shall have a min. of 8" flashing heights.
2. Field of roof is to be uniform and will ensure positive water flow to roof drains.
3. Contractor to provide tapered insulation drawings for approval. Crickets to be installed at Corners, Curbs, Etc, as Required.
4. All Electrical, Plumbing, and HVAC Disconnect/Reconnects shall be provided by the
“Contractor”.
5. Lightning Protection to be detached and reattached, by a licensed 3rd party Lightning
Protection contractor.
6. Any work being done at the roof deck level or an area with exposed interior, must get approval by owner and must be scheduled 48 hours in advance.
Expansion Joint
Equipment Support
Roof Curb
Roof Drain
Pitch Pocket
Plumbing Stack
Roof Hatch
Penetration Box
Remove Penetration
Raise Curb
Throughwall Scupper
Insulation Slope
Insulation Cricket
Heat Stack
Roof Section 6
ROOF SECTION
6 – MOD BIT
A-8
D4
D4
D4
E
N O
S H
A C
O U
N T
Y
D e te n ti o n C e n te r
B u ild in g E n v e lo p e P ro je c t th A v e
K e n o s h a W
I
SHEET NO.
The Garland Company
3800 E. 91 st
Street
Cleveland, OH 44105
SHEET TITLE:
THE INFORMATION CONTAINED HEREIN IS OF
A PROPRIETARY NATURE AND IS SUBMITTED
IN CONFIDENCE FOR USE BY THE CLIENTS
APPROVED BY THE ORIGINATOR OF THIS
DOCUMENT - ONLY. THE USE OF THESE
DOCUMENTS FOR ANY OTHER PROJECTS,
PURPOSE, LOCATION, PUBLICATION,
REPRODUCTION OR DISTRIBUTION IN WHOLE
OR PART, BY ANY INDIVIDUAL OR
ORGANIZATION WITHOUT WRITTEN
PERMISSION THE ORIGINATING COMPANY IS
PROHIBITED. THE INFORMATION HEREIN
REMAINS THE PROPERTY AND ITS USE OR
DISCLOSURE TO OTHERS IS PROHIBITED FOR
ANY USE NOT AUTHORIZED BY THE
ORIGINATING COMPANY.
12/31/2025
DETAILS
INSIDE CORNER
KENOSHA COUNTY
D1
INSIDE CORNER
KENOSHA COUNTY
D1
CURB FLASHING
KENOSHA COUNTY
2 CURB FLASHING
KENOSHA COUNTY
2 MEMBRANE SPLICE WITH SPLICE ADHESIVE
KENOSHA COUNTY
3 MEMBRANE SPLICE WITH SPLICE ADHESIVE
KENOSHA COUNTY
PIPE PENETRATION
KENOSHA COUNTY
4 PIPE PENETRATION
KENOSHA COUNTY
4 PITCH POCKET
KENOSHA COUNTY
5 PITCH POCKET
KENOSHA COUNTY
5 RAISED METAL EDGE
KENOSHA COUNTY
6 RAISED METAL EDGE
KENOSHA COUNTY
D1 D1
D1 D1 D1 D-1
E
N O
S H
A C
O U
N T
Y
D e te n ti o n C e n te r
B u ild in g E n v e lo p e P ro je c t th A v e
K e n o s h a W
I
SHEET NO.
The Garland Company
3800 E. 91 st
Street
Cleveland, OH 44105
SHEET TITLE:
THE INFORMATION CONTAINED HEREIN IS OF
A PROPRIETARY NATURE AND IS SUBMITTED
IN CONFIDENCE FOR USE BY THE CLIENTS
APPROVED BY THE ORIGINATOR OF THIS
DOCUMENT - ONLY. THE USE OF THESE
DOCUMENTS FOR ANY OTHER PROJECTS,
PURPOSE, LOCATION, PUBLICATION,
REPRODUCTION OR DISTRIBUTION IN WHOLE
OR PART, BY ANY INDIVIDUAL OR
ORGANIZATION WITHOUT WRITTEN
PERMISSION THE ORIGINATING COMPANY IS
PROHIBITED. THE INFORMATION HEREIN
REMAINS THE PROPERTY AND ITS USE OR
DISCLOSURE TO OTHERS IS PROHIBITED FOR
ANY USE NOT AUTHORIZED BY THE
ORIGINATING COMPANY.
12/31/2025
DETAILS
HEAT STACK
KENOSHA COUNTY
1 HEAT STACK
KENOSHA COUNTY
1 ROOF DRAIN
KENOSHA COUNTY
2 ROOF DRAIN
KENOSHA COUNTY
D2 D2
D-2
PARAPET/WALL FLASHING
KENOSHA COUNTY
3 PARAPET/WALL FLASHING
KENOSHA COUNTY
D2
METAL COUNTER FLASHING
KENOSHA COUNTY
4 METAL COUNTER FLASHING
KENOSHA COUNTY
D2
E
N O
S H
A C
O U
N T
Y
D e te n ti o n C e n te r
B u ild in g E n v e lo p e P ro je c t th A v e
K e n o s h a W
I
SHEET NO.
The Garland Company
3800 E. 91 st
Street
Cleveland, OH 44105
SHEET TITLE:
THE INFORMATION CONTAINED HEREIN IS OF
A PROPRIETARY NATURE AND IS SUBMITTED
IN CONFIDENCE FOR USE BY THE CLIENTS
APPROVED BY THE ORIGINATOR OF THIS
DOCUMENT - ONLY. THE USE OF THESE
DOCUMENTS FOR ANY OTHER PROJECTS,
PURPOSE, LOCATION, PUBLICATION,
REPRODUCTION OR DISTRIBUTION IN WHOLE
OR PART, BY ANY INDIVIDUAL OR
ORGANIZATION WITHOUT WRITTEN
PERMISSION THE ORIGINATING COMPANY IS
PROHIBITED. THE INFORMATION HEREIN
REMAINS THE PROPERTY AND ITS USE OR
DISCLOSURE TO OTHERS IS PROHIBITED FOR
ANY USE NOT AUTHORIZED BY THE
ORIGINATING COMPANY.
12/31/2025
DETAILS
ROOF PROFILE - MOD BIT
KENOSHA COUNTY
1 ROOF PROFILE - MOD BIT
KENOSHA COUNTY
1 HEAT STACK
KENOSHA COUNTY
2 HEAT STACK
KENOSHA COUNTY
2 PITCH POCKET WITH UMBRELLA
KENOSHA COUNTY
3 PITCH POCKET WITH UMBRELLA
KENOSHA COUNTY
CURB/AIR HANDLING STATION
KENOSHA COUNTY
4 CURB/AIR HANDLING STATION
KENOSHA COUNTY
4 SKYLIGHT
KENOSHA COUNTY
5 SKYLIGHT
KENOSHA COUNTY
5 EXHAUST FAN
KENOSHA COUNTY
6 EXHAUST FAN
KENOSHA COUNTY
D3 D3 D3
D3D3D3
D-3
E
N O
S H
A C
O U
N T
Y
D e te n ti o n C e n te r
B u ild in g E n v e lo p e P ro je c t th A v e
K e n o s h a W
I
SHEET NO.
The Garland Company
3800 E. 91 st
Street
Cleveland, OH 44105
SHEET TITLE:
THE INFORMATION CONTAINED HEREIN IS OF
A PROPRIETARY NATURE AND IS SUBMITTED
IN CONFIDENCE FOR USE BY THE CLIENTS
APPROVED BY THE ORIGINATOR OF THIS
DOCUMENT - ONLY. THE USE OF THESE
DOCUMENTS FOR ANY OTHER PROJECTS,
PURPOSE, LOCATION, PUBLICATION,
REPRODUCTION OR DISTRIBUTION IN WHOLE
OR PART, BY ANY INDIVIDUAL OR
ORGANIZATION WITHOUT WRITTEN
PERMISSION THE ORIGINATING COMPANY IS
PROHIBITED. THE INFORMATION HEREIN
REMAINS THE PROPERTY AND ITS USE OR
DISCLOSURE TO OTHERS IS PROHIBITED FOR
ANY USE NOT AUTHORIZED BY THE
ORIGINATING COMPANY.
12/31/2025
DETAILS
DETAIL REQUIRMENTS
1) Details shown are representative of finished details. Contractors shall take into account existing insulation, new insulation, and the new roof system. Wood blocking shall be added to achieve the minimum flashing heights shown.
2) All one piece sheet metal fascia is limited to a maximum of 8". Any face metal extending beyond 8" must have two piece metal and two keeper strips.
RAISED METAL EDGE
KENOSHA COUNTY
2 RAISED METAL EDGE
KENOSHA COUNTY
2ROOF DRAIN
KENOSHA COUNTY
1 ROOF DRAIN
KENOSHA COUNTY
D4 D4
D-4
SURFACED MOUNTED COUNTER FLASHING
KENOSHA COUNTY
3 SURFACED MOUNTED COUNTER FLASHING
KENOSHA COUNTY
| Kenosha County - KCDC Building Envelope Project - Drawings 12.4.2025.vsdm |
| Page-1 |
| Page-2 |
| Page-3 |
| Page-4 |
| Page-5 |
| Page-6 |
| Page-7 |
| Page-8 |
| Page-9 |
| Page-10 |
| Page-11 |
| Page-12 |
| Page-13 |
File details come from the government source that posted it. Updated .