260-B5260-007 CM Engineering Lab & Pantry - Bid Set _Drawings.pdf

PDF 3 MB Posted

Attached to
260-B5260-007 CM Engineering Lab & Pantry
Solicitation number
IFB-129584
Issued by
Fairfax County, Virginia

About this file

This is a bid set drawing document for a construction project at Northern Virginia Community College (NVCC) Annandale Campus, prepared under Virginia state building code authority through the Department of General Services, Division of Engineering and Buildings. The project (PC No. 260-B5260-007) involves the conversion of an existing office suite into an engineering laboratory classroom and the conversion of a copier room into a pantry on the third floor of the CM Building, located at 8333 Little River Turnpike, Annandale, Virginia 22003. The project scope includes architectural, mechanical, electrical, plumbing, fire alarm, and fire suppression work affecting approximately 1,675 square feet. The work is classified as a Chapter 6 Alteration Level 2 under the Virginia Existing Building Code 2021 Edition. The bid set includes comprehensive construction documents with general notes, demolition and new work plans, interior elevations, mechanical systems, plumbing and electrical plans, and fire protection system details prepared by Cole and Denny Architects and consultants Engenium Group and GHD Inc., with a bid set submission date of September 4, 2026.

The project is subject to the Virginia Uniform Statewide Building Code 2021 Edition, Virginia Statewide Fire Prevention Code 2021 Edition, and applicable national standards including the 2020 National Electrical Code and NFPA standards. The building is exempt from High Performance Buildings Act compliance as renovation costs do not exceed 50 percent of the building value, though Virginia Energy Conservation Code sections C402 through C405 and C408 must be satisfied. Key execution requirements include pantry work performed during overnight hours (6:00 PM to 6:00 AM) to minimize disruption to adjacent academic operations, with all other work permitted during regular working hours after 6:00 AM. Work is prohibited during finals weeks (December 8-14, 2026 and May 4-10, 2027). The building will remain occupied during construction, requiring contractor coordination with the Owner's Representative Kaylin Brewer (KBREWER@NVCC.EDU, 260-580-4909). Delegated design systems requiring Virginia-registered engineer completion and state building official approval include fire alarm, fire suppression, and access control systems.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STEEL

WOOD LUMBER

ROOM NAME &

NUMBER

PARTITION TYPE

DOOR TYPE#

SECTION REFERENCE

SECTION NUMBER

SHEET NUMBER WHERE

DETAIL IS LOCATED

SHEET NUMBER WHERE

DETAIL IS REFERENCED

FROM

DETAIL REFERENCE

DETAIL NUMBER

SHEET NUMBER

WHERE SECTION IS

REFERENCED FROM

SHEET NUMBER WHERE

SECTION IS LOCATED

INTERIOR ELEVATION

ELEVATION NUMBER

SHEET NUMBER WHERE

ELEVATION IS LOCATED

SECTION NUMBER

SHEET NUMBER WHERE

SECTION IS LOCATED

NAME

# COLUMN GRID

PROJECT LOCATION:

NVCC ANNANDALE CAMPUS

I-66

I-

Little River Turnpike

I-3 95W ak e fie ld C ha p e l R d

N

RT 234

AREA OF WORK

N

NOT IN CONTRACT

NEW CONSTRUCTION

TO BE DEMOLISHED

General

G0.01 Cover Sheet

G0.02 General Notes

G0.03 UL Detail for Temporary Partition

G1.01 Egress, Occupancy & Fire Resistance Rating Plan

G1.02 Temporary Construction Partition Plan

G1.03 Occupany Plans and Plumbing Fixture Calculations

Architectural

AD1.01 Third Floor Demolition Plan & RCP

A1.01 Third Floor Plan, RCP, Furniture & Equipment Schedule

A4.01 Interior Elevations & Millwork Details

A4.02 Interior Elevations & Details

A5.01 Partition Types & Door & Window Detail

A6.01 Finish Plan & Schedule

Mechanical

M0.01 Mechanical Cover Sheet

M1.00 Mechanical Level 3 Demolition & New Work Plans

M6.01 Mechanical Details

M7.01 Mechanical Schedules

M8.01 Mechanical Controls & Calculations

Plumbing

P0.01 Plumbing Cover Sheet

P2.01 Plumbing Level 3 New Work Plans

P5.01 Plumbing Riser Diagrams

P6.01 Plumbing Details

P7.01 Plumbing Schedules

Electrical

E0.01 Electrical Cover Sheet

E0.02 Electrical Lighting Compliance

E1.01 Electrical Level 3 Demolition

E2.01 Lighting Level 3 New Work

E3.01 Electrical Level 3 & Penthouse New Work

E5.01 Electrical Details

E7.01 Electrical Riser Diagram & Schedules

E7.02 Electrical Schedules

Fire Alarm

FA0.01 Reference Sheet - Fire Alarm

FA1.01 Partial Third Floor Plans - Demolition

FA1.11 Partial Third Floor Plan - Proposed

FA5.01 Detail Sheet, Diagrams & Schedules - Fire Alarms

Fire Suppression

SP0.01 Reference Sheet - Fire Alarm

SP1.01 Partial Third Floor Plans - Demolition

SP1.11 Partial Third Floor Plan - Proposed

SP5.01 Detail Sheet, Diagrams & Schedules - Sprinkler

SHEET INDEX

NVCC CM Building

Engineering Lab & Pantry NVCC Annandale Campus 8333 Little River Turnpike Annandale, VA 22003

DESCRIPTION OF WORK

ASBESTOS DISCLOSURE STATEMENT

LEAD-BASED PAINT DISCLOSURE STATEMENT

AN ASBESTOS INSPECTION WAS NOT PERFORMED BECAUSE ALL PORTIONS OF THE EXISTING BUILDING THAT MAY BE AFFECTED BY THE WORK WERE ORIGINALLY CONSTRUCTED AFTER JANUARY 1, 1985. NO ASBESTOS CONTAINING

MATERIALS SHALL BE USED ON THE PROJECT.

APPLICABLE CODES

THE BUILDING CODE AUTHORITY IS THE VIRGINIA DEPARTMENT OF GENERAL SERVICES

(DGS), DIVISION OF ENGINEERING AND BUILDINGS (DEB).

THE BUILDING CODE FOR THIS PROJECT IS THE VIRGINIA UNIFORM STATEWIDE

BUILDING CODE (VUSBC) 2021 EDITION, EFFECTIVE JANUARY 18, 2024.

THE PROJECT IS CLASSIFIED AS A CHAPTER 6 ALTERATION LEVEL 2 UNDER PART II OF

THE VIRGINIA EXISTING BUILDING CODE (VEBC) 2021 EDITION. ALL WORK SHALL

CONFORM TO THE BUILDING CODE.

THE BUILDING IS DESIGNATED UNDER THE VCCS CONSTRUCTION AND PROFESSIONAL

SERVICES MANUAL (VCCS-CPSM) 2022 EDITION AND THE CONSTRUCTION AND

PROFESSIONAL SERVICES MANUAL (DGS-CPSM) 2026 EDITION, REVISION 0.

THE COMPLIANCE PATH FOR ACCESSIBILITY FOR THIS PROJECT IS ADA90-TITLE II. THE

ADA STANDARD FOR SCOPE OF WORK IS CHAPTER 2 OF THE DOJ'S 2010 ADA

STANDARDS FOR ACCESSIBLE DESIGN ARE CHAPTERS 1 & 3 THRU 11 OF STANDARDS

FOR ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES A117.1-2017, APPROVED

MARCH 28, 2017.

THE FIRE CODES FOR THIS PROJECT ARE THE VIRGINIA STATEWIDE FIRE PREVENTION

CODE (SFPC) 2021 EDITION, THE 2021 VIRGINIA CONSTRUCTION CODE (VCC)

CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION, THE 2021 INTERNATIONAL FIRE

CODE CHAPTER 22 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION, THE

NFPA13 2019 EDITION, NFPA70 2020 EDITION, AND NFPA72 2019 EDITION.

ALL ELECTRICAL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THE 2020

NATIONAL ELECTRICAL CODE (NEC) AS MODIFIED BY VCC CHAPTER 27, ALL OTHER

APPLICABLE VIRGINIA CONSTRUCTION CODES, AND THE AUTHORITY HAVING

JURISDICTION (VIRGINIA DIVISION OF ENGINEERING AND BUILDINGS).

MATERIALS

DRAWING SYMBOLS

CODE SUMMARY

ORIGINAL CODE BUILT UNDER:

ORIGINAL YEAR BUILT:

1993 USE GROUP:

2021 USE & OCCUPANCY CLASSIFICATION:

1993 CONSTRUCTION TYPE:

2021 CONSTRUCTION TYPE:

SPRINKLERED:

FIRE ALARM:

EXISTING BUILDING AREA:

EXISTING BUILDING HEIGHT:

PROJECT AREA:

ESTIMATED EXISTING OCCUPANT LOAD:

THIRD FLOOR:

SECOND FLOOR:

FIRST FLOOR:

ESTIMATED NEW OCCUPANT LOAD:

THIRD FLOOR:

SECOND FLOOR:

FIRST FLOOR:

VUSBC 1993

E - EDUCATION

B - BUSINESS

IIC

IIB

YES, FULLY

YES, FULLY

58, 912 SF

4 STORIES, 58.25 FT

1,675 SF

250 OCC

505 OCC

278 OCC

271 OCC

505 OCC (NO CHANGE)

278 OCC (NO CHANGE)

CAMPUS MAP

ABBREVIATIONS

PHASING

# NUMBER

& AND

@ AT

ACP ACOUSTICAL CEILING PANEL

AFF ABOVE FINISH FLOOR

AH ACTUAL HEIGHT

ALUM ALUMINUM

ASTM AMERICAN SOCIETY OF TESTING & MATERIALS

BD BUILDING

BOT BOTTOM

CJ CONTROL JOINT

CLG CEILING

CLOS CLOSET

CONC CONCRETE

CONT CONTINUOUS

CPT CARPET

CR CARD READER

D DATA

DEMO DEMOLITION

DF DRINKING FOUNTAIN

DIA DIAMETER

DN DOWN

EDA ELECTRONIC DOOR ACCESS

EF EXHAUST FAN

EL ELEVATION

ELEC ELECTRICAL

ELEV ELEVATOR

EQ EQUAL

EQUIP EQUIPMENT

ETR EXISTING TO REMAIN

EW EYEWASH

EXIST EXISTING

EXT EXTERIOR

FE FIRE EXTINGUISHER

FLR FLOOR

FRT FIRE RETARDANT TREATED

FT FEET/FOOT

GA GAUGE

GALV GALVANIZED

GWB GYPSUM WALL BOARD

HDWR HARDWARE

HM HOLLOW METAL

HR HOUR

IN INCH

VICINITY MAP

N

THE FOLLOWING SYSTEMS AS LISTED IN THE CONTRACT DOCUMENTS ARE DELEGATED DESIGNS TO BE COMPLETED BY A REGISTERED ENGINEER IN THE COMMONWEALTH OF VIRGINIA UNDER THE CONTRACTOR'S SCOPE OF WORK:

SYSTEMS WITH SHOP DRAWINGS REVIEW/APPROVAL REQUIRED BY THE STATE BUILDING OFFICIAL (DEB) AFTER THE A/E SHOP

DRAWING REVIEW/APPROVAL:

1. FIRE ALARM

2. FIRE SUPPRESSION (SPRINKLER)

3. ACCESS CONTROL

SYSTEMS WITH SHOP DRAWING REVIEW/APPROVAL REQUIRED BY THE A/E:

1. METAL STUD WALL: NON-LOAD BEARING

2. DUCTWORK SUPPORT HANGERS

3. PIPE SUPPORT HANGERS

DELEGATED DESIGN SUMMARY

PROJECT LOCATION

PC No.: 260-B5260-007

HIGH PERFORMANCE BUILDINGS ACT

COMPLIANCE STATEMENT

IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT FROM COMPLIANCE BECAUSE THE

COST OF THE RENOVATIONS DOES NOT EXCEED 50% OF THE VALUE OF THE BUILDING.

VIRGINIA ENERGY CONSERVATION CODE

COMPLIANCE STATEMENT

IN ACCORD WITH THE VIRGINIA ENERGY CONSERVATION CODE (VECC), THE BUILDING SHALL COMPLY WITH VECC SECTIONS

C402 THROUGH C405 AND C408.

FIRE-RESISTANCE - TABLE 601

STRUCTURAL FRAME:

EXTERIOR BEARING WALL:

INTERIOR BEARING WALL:

NONBEARING WALLS:

FLOOR:

ROOF:

IIC - VUSBC 1993

0 HOURS

N/A

N/A

0 HOURS

0 HOURS

0 HOURS

IIB - VUSBC 2021

0 HOURS

N/A

N/A

0 HOURS

0 HOURS

0 HOURS

Consultants

703.684.5994

277 S Washington St, Ste 385

Alexandria, Virginia 22314

Seal

Key Plan

Drawing

Revisions

Date

Project No.

Sheet No.

Bid Set 09/04/2026

Submission Set coleanddenny.com

Permit Electronic Approval Stamp

Mechanical, Electrical, Plumbing Engineers

Engenium Group

Fire Suppression & Fire Alarm Engineers

GHD Inc.

655 New York Ave Suite MZ02 Washington D.C. 20001

14501 George Carter Way, Suite 102 Chantilly, VA 20151

September 04, 2026

20005.30

8333 Little River Turnpike Annandale, VA 22003

PC No.: 260-B5260-007

NVCC CM Building Engineering Lab & Pantry

G0.01

Cover Sheet

LAE

WN

O M

M O

OF

I

NI

G

RI

H V

E C TCRA

MICHAEL DETOMO

Lic. No. 15799

T

C

A

IH T 09/04/2026

INSUL INSULATION

INT INTERIOR

JT JOINT

KS KITCHEN SINK

LAV LAVATORY

LRG LARGE

LVT LUXURY VINYL TILE

MAX MAXIMUM

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MTL METAL

N NORTH

NIC NOT IN CONTRACT

NO NUMBER

OC ON CENTER

P POWER

PL PLASTIC LAMINATE

PLUMB PLUMBING

PLYWD PLYWOOD

PT PRESSURE TREATED

PTD PAINTED

PVC POLYVINYL CHLORIDE

RB RESILIENT BASE

RCP REFLECTED CEILING PLAN

REQ'D REQUIRED

RM ROOM

SCW SOLID CORE WOOD

SF SQUARE FOOT/FEET

SIM SIMILAR

SSM SOLID SURFACING MATERIAL

SST STAINLESS STEEL

STOR STORAGE

STRUCT STRUCTURAL

TH THERMOSTAT

THRU THROUGH

TOS TOP OF STEEL

TYP TYPICAL

UL UNDERWRITER'S LABORATORIES

UNO UNLESS NOTED OTHERWISE

VCT VINYL COMPOSITE TILE

VIF VERIFY IN FIELD

W/ WITH

WB WHITEBOARD

WC WATER CLOSET

THE PROJECT CONSISTS OF THE CONVERSION OF AN EXISTING OFFICE SUITE INTO AN

ENGINEERING LABORATORY CLASSROOM AND THE CONVERSION OF A COPIER ROOM

INTO A PANTRY ON THE THIRD FLOOR OF THE CM BUILDING.

AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS HAS NOT BEEN CONDUCTED BECAUSE THE BUILDING WAS CONSTRUCTED AFTER JANUARY 1, 1985 AND THE OWNER HAS NO KNOWLEDGE OF LEAD CONTAINING OR COATED BUILDING COMPONENTS IN THE BUILDING. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL SAFETY & HEALTH (VOSH) REGULATIONS AS THE PERTAIN TO EMPLOYEE EXPOSURES TO LEAD, ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE RECYCLED TO THE EXTENT POSSIBLE.

OWNER'S REPRESENTATIVE

THE OWNER'S REPRESENTATIVE FOR THE NORTHERN VIRGINIA COMMUNITY

COLLEGE CM BUILDING IS:

KAYLIN BREWER,

FACILITIES MANAGEMENT

8333 LITTLE RIVER TURNPIKE, CW BUILDING 311,

ANNANDALE, VA 22003

PHONE: 260-580-4909

EMAIL: KBREWER@NVCC.EDU

No. Revision Date

Consultants

703.684.5994

277 S Washington St, Ste 385

Alexandria, Virginia 22314

Seal

Key Plan

Drawing

Revisions

Date

Project No.

Sheet No.

Bid Set 09/04/2026

Submission Set coleanddenny.com

Permit Electronic Approval Stamp

Mechanical, Electrical, Plumbing Engineers

Engenium Group

Fire Suppression & Fire Alarm Engineers

GHD Inc.

655 New York Ave Suite MZ02 Washington D.C. 20001

14501 George Carter Way, Suite 102 Chantilly, VA 20151

September 04, 2026

20005.30

8333 Little River Turnpike Annandale, VA 22003

PC No.: 260-B5260-007

NVCC CM Building Engineering Lab & Pantry

G0.02

General Notes

LAE

WN

O M

M O

OF

I

NI

G

RI

H V

E C TCRA

MICHAEL DETOMO

Lic. No. 15799

T

C

A

IH T 09/04/2026

A. PRICING

THE GENERAL CONTRACTOR SHALL PROMPTLY NOTIFY THE ARCHITECT AND OWNER FOR

CLARIFICATION OF ANY AMBIGUITY OR INCONSISTENCY WHICH MAY BE DISCOVERED

UPON EXAMINATION OF THE CONSTRUCTION DOCUMENTS OR THE SITE AND EXISTING

CONDITIONS PRIOR TO SUBMITTING A PRICE. THE GENERAL CONTRACTOR, BY MAKING A

BID, REPRESENTS THAT:

A. THE GENERAL CONTRACTOR HAS READ AND UNDERSTANDS THE DOCUMENTS AND

THE BID IS MADE IN ACCORDANCE THEREWITH.

B. THE GENERAL CONTRACTOR HAS VISITED THE SITE TO OBSERVE THE SCOPE OF

WORK IDENTIFIED ON THE DRAWINGS, IS FAMILIAR WITH THE SITE, JOB CONDITIONS,

AND JURISDICTIONAL REQUIREMENTS UNDER WHICH THE WORK IS TO BE PERFORMED,

AND HAS CORRELATED OBSERVATIONS WITH THE REQUIREMENTS OF THE CONTRACT

DOCUMENTS.

C. THE GENERAL CONTRACTOR'S PRICE IS BASED UPON THE MATERIALS, SYSTEMS,

AND EQUIPMENT REQUIRED BY THE BIDDING DOCUMENTS WITHOUT EXCEPTION.

B. OWNER OCCUPANCY

THE BUILDING AND SITE WILL BE OCCUPIED DURING CONSTRUCTION. THE CONTRACTOR

SHALL OBTAIN THE OWNER'S APPROVAL AND COORDINATE AND SCHEDULE IN ADVANCE

WITH THE OWNER ALL WORK THAT MAY AFFECT THE OWNER'S OPERATIONS. SUCH WORK

INCLUDES DELIVERIES, STORAGE OF MATERIALS, STAGING OPERATIONS, INTERIOR WORK

INCLUDING REMOVAL AND REPLACEMENT INTERIOR FINISHES AND WORK ABOVE THE

CEILINGS, INTERRUPTIONS IN POWER, AIR CONDITIONING AND HEATING, AND SIMILAR

WORK. IF NECESSARY TO ACCOMMODATE THE OWNER'S SCHEDULE, SOME OUTAGES MAY

NEED TO BE SCHEDULED AFTER HOURS OR ON WEEKENDS. WORK IS PROHIBITED DURING

'FINALS WEEKS'; DECEMBER 8-14, 2026 AND MAY 4-10, 2027. SEE SPECIFICATIONS.

ADDITIONAL REQUIREMENTS: THE PANTRY WORK SHALL BE PERFORMED DURING

OVERNIGHT HOURS (I.E., NIGHT WORK) TO MINIMIZE DISRUPTION TO THE ADJACENT

ACADEMIC DEPARTMENT. NIGHT WORK SHALL BE PERFORMED OUTSIDE NORMAL CAMPUS

OPERATING HOURS. UNLESS OTHERWISE APPROVED BY THE OWNER, NIGHT WORK MAY

OCCUR BETWEEN 6:00 PM AND 6:00 AM. ALL OTHER WORK, INCLUDING THE LABORATORY

WORK, MAY BE PERFORMED DURING REGULAR WORKING HOURS AFTER 6:00AM.

C. MEASUREMENTS & EXISTING CONDITIONS

DIMENSIONS ARE FROM FINISHED FACE OF CONSTRUCTION TO FINISH FACE OF

CONSTRUCTION UNLESS NOTED OTHERWISE. INFORMATION CONTAINED IN THESE

DOCUMENTS IS BASED ON EXISTING DOCUMENTS AND FIELD MEASUREMENTS. THE

CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND ALL MEASUREMENTS AT THE

BUILDING AND SHALL BE RESPONSIBLE FOR CORRECTNESS OF SAME. WHERE CONFLICTS

OCCUR BETWEEN THE DOCUMENTS AND THE EXISTING CONDITIONS, THE CONTRACTOR

SHALL NOTIFY THE ARCHITECT FOR RESOLUTION OF DISCREPANCIES BEFORE PROCEEDING

WITH THE WORK. CONTACT THE OWNER'S REPRESENTATIVE FOR THE HAZARDOUS

MATERIAL SURVEY REPORT.

D. DEMOLITION

DEMOLITION INCLUDES CONTROLLED DESTRUCTION OF EXISTING CONSTRUCTION AND THE

REMOVAL AND DISPOSAL OF DEMOLISHED MATERIALS AS SHOWN ON THE DRAWINGS

AND/OR INCLUDED IN THESE NOTES. DEMOLITION SHALL BE PERFORMED IN SECTIONS

SMALL ENOUGH SO AS NOT TO ENDANGER ANY ADJACENT MATERIALS OR FACILITIES TO

REMAIN IN PLACE. PROVIDE ADEQUATE SHORING, BRACING, AND PROTECTION TO

PREVENT MOVEMENT, SETTLEMENT, COLLAPSE, OR DAMAGE TO EXISTING MATERIALS OR

FACILITIES WHICH ARE TO REMAIN. CONTRACTOR SHALL SUBMIT TO THE ARCHITECT FOR

REVIEW AND ACCEPTANCE, PRIOR TO BEGINNING THE WORK, COMPLETE DETAILS OF

SHORING PROCEDURES SIGNED BY A REGISTERED PROFESSIONAL ENGINEER. PROMPTLY

REPAIR ALL DAMAGES CAUSED BY THE DEMOLITION TO ADJACENT FACILITIES OR

MATERIALS AT NO COST TO THE OWNER.

E. CUTTING & PATCHING OF THE WORK

THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, FITTING, AND PATCHING

THAT MAY BE REQUIRED TO COMPLETE THE WORK AND MAKE ITS SEVERAL PARTS FIT

TOGETHER TO ACHIEVE THE PROFESSIONAL QUALITY OF NEW WORK. WHERE EXISTING

CONSTRUCTION IS DISTURBED, THE AFFECTED AREA SHALL BE REPLACED AND REPAIRED

WITH MATCHING MATERIALS AND FINISHES AND BLENDED WITH EXISTING WORK. WHERE

PAINT CANNOT BE TOUCHED UP TO MATCH, REPAINT ENTIRE SURFACE.

F. TEMPORARY FACILITIES

THE OWNER WILL PROVIDE UTILITIES AVAILABLE FROM THE EXISTING BUILDING FOR USE BY

THE CONTRACTOR. THE CONTRACTOR SHALL PROVIDE TEMPORARY TOILET FACILITIES FOR

THE WORKMEN AND SHALL MAKE ADDITIONAL PROVISIONS IF REQUIRED TO ACCOMPLISH

THE WORK. AT THE COMPLETION OF CONSTRUCTION AND BEFORE REQUEST FOR FINAL

PAYMENT, ALL EXISTING FACILITIES USED BY THE CONTRACTOR SHALL BE CLEANED AND

RESTORED TO ORIGINAL CONDITION TO THE OWNER'S SATISFACTION.

G. TEMPORARY CONSTRUCTION BARRIERS

THE CONTRACTOR WILL COMPLY WITH THE OWNER'S AND LOCAL JURISDICTION'S

REQUIREMENTS FOR ERECTION OF NON-COMBUSTIBLE SAFETY BARRICADES FOR

PROTECTION OF PEOPLE AND PROPERTY AT AND AROUND ALL WORK AREAS. PAINT WITH

APPROPRIATE COLORS, GRAPHICS, AND WARNING SIGNS TO INFORM PERSONNEL AND

THE PUBLIC OF THE HAZARD BEING PROTECTED AGAINST. THE CONTRACTOR MUST

MAINTAIN ACCESS TO ALL EXITS AND MAINTAIN REQUIRED EGRESS PASSAGE WIDTHS

THROUGHOUT THE DEMOLITION AND CONSTRUCTION PERIOD. THE EGRESS PASSAGE MAY

NOT BE USED AS A PATHWAY TO TRANSPORT MATERIALS TO AND FROM THE AREA OF

WORK WHILE THE BUILDING IS OCCUPIED.

H. FIELD COORDINATION

CONTRACTOR SHALL COORDINATE BUILDING ACCESS NECESSARY TO PERFORM THE

WORK WITH THE OWNER'S REPRESENTATIVE. CONTRACTOR SHALL PROTECT THE SPACE

AND EQUIPMENT THAT IS OUTSIDE OF THE SPECIFIC AREA OF WORK FROM DAMAGE.

SHOULD ANY DAMAGE OCCUR, CONTRACTOR SHALL REPAIR TO THE OWNER'S

SATISFACTION AT NO ADDITIONAL COST TO THE OWNER.

I. WORK EXECUTION

ALL MATERIALS AND PRODUCTS ARE TO BE MANUFACTURED, ASSEMBLED, AND INSTALLED

IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, REQUIREMENTS, AND

SHOP DRAWINGS. WHERE REQUIRED, THE CONTRACTOR SHALL PROCURE A HOT WORK

PERMIT FROM THE FACILITY MANAGER, AND SHALL POST A FIRE WATCH COMPLYING WITH

CHAPTER 26 OF THE VIRGINIA STATEWIDE FIRE PREVENTION CODE FOR ANY WELDING AND

OTHER HOT WORK. THE FIRE WATCH SHALL EXTEND A MINIMUM OF TWO HOURS AFTER

THE WELDING AND/OR HOT WORK IS COMPLETE.

J. CLEANING

THE WORK SITE MUST BE KEPT CLEAN OF CONSTRUCTION DEBRIS AND DISCARDED

PACKAGING MATERIAL. THE CONTRACTOR SHALL ARRANGE FOR HIS OWN TRASH

CONTAINERS AND THEIR REMOVAL. LOCATION OF THE CONTAINERS MUST BE

COORDINATED WITH THE OWNER'S REPRESENTATIVE. TRASH TO BE DISPOSED OF IN A

PROPER AND LEGAL MANNER. ALL WORK SHALL BE THOROUGHLY CLEANED AND POLISHED

BEFORE FINAL INSPECTION. CLEANING MUST BE APPROVED BY THE OWNER PRIOR TO

FINAL ACCEPTANCE.

GENERAL NOTES

K. SHOP DRAWINGS & SUBMITTALS

SUBMIT SHOP DRAWINGS AND PRODUCT DATA TO THE ARCHITECT FOR THE FOLLOWING

ITEMS. SHOP DRAWINGS, PRODUCT DATA, WARRANTIES, OPERATION AND MAINTENANCE

MANUALS, QUALIFICATIONS, AND OTHER REQUIRED APPLICABLE INFORMATION FOR A

SINGLE SPECIFICATION SECTION SHALL BE CONSOLIDATED INTO ONE SUBMITTAL OR AS

FEW SUBMITTALS AS ECONOMICALLY POSSIBLE. SHOP DRAWINGS SHALL BE SUFFICIENT IN

SCALE AND DETAIL TO INDICATE MATERIALS, METHODS OF FABRICATION, JOINTS, AND

GENERAL CONFIGURATION. WORK SHALL NOT COMMENCE ON EACH ITEM UNTIL THE

OWNER HAS APPROVED THE SUBMITTAL. SUBMIT SAMPLES FOR ITEMS BELOW MARKED

WITH AN ASTERISK (*).

A. SEALANT & BACKER ROD*

B. GLAZING*

C. ALUMINUM-FRAMED STOREFRONT WINDOWS*

D. CEILING PANELS & GRID SYSTEMS

E. PAINT*

F. SURFACE CLEANER

WORK SHALL NOT COMMENCE UNTIL THE OWNER'S REPRESENTATIVE HAS APPROVED THE

SUBMITTAL. PROTECTIVE MEASURES SHALL BE EMPLOYED PRIOR TO THE COMMENCEMENT

OF WORK FOR EACH PHASE AND SHALL BE PROMPTLY REMOVED UPON COMPLETION OF

EACH PHASE. PROTECTIVE MEASURES SHALL BE RE-EMPLOYED PRIOR TO FACADE

CLEANING. PROMPTLY REPLACE DAMAGED PLANT MATERIALS CAUSED BY PHASED WORK

WITH LIKE SIZE AND KIND AT NO COST TO THE OWNER

Consultants

703.684.5994

277 S Washington St, Ste 385

Alexandria, Virginia 22314

Seal

Key Plan

Drawing

Revisions

Date

Project No.

Sheet No.

Bid Set 09/04/2026

Submission Set coleanddenny.com

Permit Electronic Approval Stamp

Mechanical, Electrical, Plumbing Engineers

Engenium Group

Fire Suppression & Fire Alarm Engineers

GHD Inc.

655 New York Ave Suite MZ02 Washington D.C. 20001

14501 George Carter Way, Suite 102 Chantilly, VA 20151

September 04, 2026

20005.30

8333 Little River Turnpike Annandale, VA 22003

PC No.: 260-B5260-007

NVCC CM Building Engineering Lab & Pantry

G0.03

UL Detail for Temporary Partition

UL DESIGN V438 (FOR ONE HOUR FIRE RESISTANCE RATED TEMPORARY PARTITIONS)

For UL assemblies, UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: (a) The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings) (b) The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the format required in the listing, such as '© 2025 UL LLC."

LAE

WN

O M

M O

OF

I

NI

G

RI

H V

E C TCRA

MICHAEL DETOMO

Lic. No. 15799

T

C

A

IH T 09/04/2026

2-HR FIRE BARRIER

EGRESS STARTING POINT

POINT AT WHICH A CHOICE OF

TWO EXITS BECOMES AVAILABLE

REMAINING TRAVEL DISTANCE

(REMAINING TRAVEL DISTANCE +

COMMON PATH OF TRAVEL <300')

COMMON PATH OF TRAVEL (<100')

EGRESS LEGEND

1-HR FIRE BARRIER

RATING LEGEND

LIFE SAFETY

DEVICES LEGEND

FULLY RECESSED, WALL MOUNTED

FIRE EXTINUISHER U.N.O.; CLASS

INDICATED ON PLAN

FE-#

EXIT SIGN - SEE ELECTRICAL

CARD READERCR

LOUNGE

STOR

COPIER

SEC

342A

OFF

332A

CLOS

60'-6"

327H

LIB

BREAK

301C

ELEV

327G

OPEN

OFF

327A

OFF

327B

OFF

327C

OFF

327D

OFF

327E

OFF

327F

OFF

'-7

154'-9"

STAIR

139'-2"

29'-7"

301B

STAIR

20'-6"

342C

OFF

342B

OFF

WOMEN

MEN

STAIR

PANTRY

1416 SF

ENG LAB

203'-7"

301C

ELEV

'-1

17'-11"

75'-3"

301B

STAIR

SEC

342C

OFF

342B

OFF

'-1

'-7

LOUNGE

332A

CLOS

MEN

WOMEN

FE-ABC

FE-ABC

SURFACE

MOUNTED

FE

SURFACE

MOUNTED FE

CR

CR

C R

AREA OF WORK

N

NOT IN CONTRACT

AREA OF WORK

Consultants

703.684.5994

277 S Washington St, Ste 385

Alexandria, Virginia 22314

Seal

Key Plan

Drawing

Revisions

Date

Project No.

Sheet No.

Bid Set 09/04/2026

Submission Set coleanddenny.com

Permit Electronic Approval Stamp

Mechanical, Electrical, Plumbing Engineers

Engenium Group

Fire Suppression & Fire Alarm Engineers

GHD Inc.

655 New York Ave Suite MZ02 Washington D.C. 20001

14501 George Carter Way, Suite 102 Chantilly, VA 20151

September 04, 2026

20005.30

8333 Little River Turnpike Annandale, VA 22003

PC No.: 260-B5260-007

NVCC CM Building Engineering Lab & Pantry

G1.01

Egress, Occupancy & Fire Resistance Rating Plan

1/16" = 1'-0"G1.01

1 EXIST THIRD FLOOR PLAN - OCCUPANCY & EGRESS PLAN

1/16" = 1'-0"G1.01

2 NEW THIRD FLOOR PLAN - OCCUPANCY & EGRESS

0' 10' 20' 30'

SCALE: 1/16" = 1'-0"

PHASING

N

RM. No. RM NAME AREA FUNCTION OF SPACE LOAD FACTOR OCC LOAD

327 BREAK 109 SF ASSEMBLY (TABLES & CHAIRS) 15 7 OCC

327A OFFICE 101 SF BUSINESS 150 1 OCC

327B OFFICE 114 SF BUSINESS 150 1 OCC

327C OFFICE 120 SF BUSINESS 150 1 OCC

327D OFFICE 57 SF BUSINESS 150 1 OCC

327E OFFICE 69 SF BUSINESS 150 1 OCC

327F OFFICE 59 SF BUSINESS 150 1 OCC

327G OPEN OFFICE 734 SF CONCENTRATED BUSINESS 50 14 OCC

327H LIBRARY 47 SF ASSEMBLY 100 1 OCC

337 STORAGE 128 SF STORAGE 300 1 OCC

TOTAL 28 OCC

RM. No. RM NAME AREA FUNCTION OF SPACE LOAD FACTOR OCC LOAD

327 ENG LAB 930 SF VOCATIONAL CLASSROOM 50 48 OCC

TOTAL 48 OCC

EXIST OCCUPANCY LOAD - SUITE 327 EXIST OCCUPANCY LOAD - ROOM 340

NEW OCCUPANCY LOAD - ROOM 340NEW OCCUPANCY LOAD - SUITE 327

RM. No. RM NAME AREA FUNCTION OF SPACE LOAD FACTOR OCC LOAD

340 PANTRY 183 SF ASSEMBLY (TABLES & CHAIRS) 15 12 OCC

TOTAL 12 OCC

RM. No. RM NAME AREA FUNCTION OF SPACE LOAD FACTOR OCC LOAD

340 COPIER 183 SF BUSINESS 150 1 OCC

TOTAL 1 OCC

LAE

WN

O M

M O

OF

I

NI

G

RI

H V

E C TCRA

MICHAEL DETOMO

Lic. No. 15799

T

C

A

AREA OF WORK

N

PNLJHG

STOR

LACTATION RM

STOR

300C

CORR

STOR

ELEC

MEN

COMM

CLOS

SEC

342A

OFF

332A

CLOS

JAN

WOMEN

LOUNGE

301C

ELEV

OFF

OFF

OFF

OFF

OFF

OFF

OFF

STAIR

342D

STOR

SHAFT

SHAFT

6' -0

6' -0

MAINTAIN 60" CLEAR

ONE HOUR FIRE

RESISTANCE RATED

TEMPORARY

CONSTRUCTION

BARRIER WITH 45

MINUTE FIRE RATED

DOOR - SEE UL V438

ON SHEET G0.03

GC NOTE: ERECT TEMP

PARTITION IN

CORRIDOR AT A TIME

TO ENSURE 60" CLEAR

EGRESS AT ALL TIMES

ONE HOUR FIRE

RESISTANCE RATED

TEMPORARY

CONSTRUCTION

BARRIER WITH 45

MINUTE FIRE RATED

DOOR - SEE UL V438

ON SHEET G0.03

M

3.1

7.1

K

342C

OFF

342B

OFF

327G

OPEN

OFFICE

COPIER

327H

LIBRARY

327D

OFF

327C

OFF

327B

OFF

327A

OFF

327E

OFF

327F

OFF

BREAK

ONE HOUR FIRE

RESISTANCE RATED

TEMPORARY

CONSTRUCTION

BARRIER WITH 45

MINUTE FIRE RATED

DOOR - SEE UL V438

ON SHEET G0.03

T

T

T

T

T

T

T1

T2

A5.01G1.02

A5.01G1.02

TYP

TYP

5'-0"

T3

NOT IN CONTRACT

NEW CONSTRUCTION

TO BE DEMOLISHED

Consultants

703.684.5994

277 S Washington St, Ste 385

Alexandria, Virginia 22314

Seal

Key Plan

Drawing

Revisions

Date

Project No.

Sheet No.

Bid Set 09/04/2026

Submission Set coleanddenny.com

Permit Electronic Approval Stamp

Mechanical, Electrical, Plumbing Engineers

Engenium Group

Fire Suppression & Fire Alarm Engineers

GHD Inc.

655 New York Ave Suite MZ02 Washington D.C. 20001

14501 George Carter Way, Suite 102 Chantilly, VA 20151

September 04, 2026

20005.30

8333 Little River Turnpike Annandale, VA 22003

PC No.: 260-B5260-007

NVCC CM Building Engineering Lab & Pantry

G1.02

Temporary Construction Partition Plan

1/8" = 1'-0"G1.02

1 TEMPORARY CONSTRUCTION PARTITION PLAN

5'0' 10' 20'

SCALE: 1/8" = 1'-0"

N

PHASING

LAE

WN

O M

M O

OF

I

NI

G

RI

H V

E C TCRA

MICHAEL DETOMO

Lic. No. 15799

T

C

A

MEN

4 WC

4 LAV

WOMENEX DF

EX DF

4 WC

4 LAV

MEN

5 WC

5 LAV

7 WC

5 LAV

WOMENEX DF

EX DF

3 WC

WC

MEN

WOMENEX DF

EX DF

3 LAV

4 LAV

LAV

EX DF

EX DF

3 WC

WC

MEN

WOMEN

3 LAV

4 LAV

LAV

VOCATIONAL CLASSROOM 50

CLASSROOM 20

OFFICE 150

MECH / STORAGE 300

AREA OF WORK

N

Consultants

703.684.5994

277 S Washington St, Ste 385

Alexandria, Virginia 22314

Seal

Key Plan

Drawing

Revisions

Date

Project No.

Sheet No.

Bid Set 09/04/2026

Submission Set coleanddenny.com

Permit Electronic Approval Stamp

Mechanical, Electrical, Plumbing Engineers

Engenium Group

Fire Suppression & Fire Alarm Engineers

GHD Inc.

655 New York Ave Suite MZ02 Washington D.C. 20001

14501 George Carter Way, Suite 102 Chantilly, VA 20151

September 04, 2026

20005.30

8333 Little River Turnpike Annandale, VA 22003

PC No.: 260-B5260-007

NVCC CM Building Engineering Lab & Pantry

G1.03

Occupany Plans and Plumbing Fixture Calculations

LAE

WN

O M

M O

OF

I

NI

G

RI

H V

E C TCRA

MICHAEL DETOMO

Lic. No. 15799

T

C

A

IH T 09/04/2026

1" = 30'-0"A2.01 G1.03

1 EXISTING FIRST FLOOR OCCUPANCY PLAN

1" = 30'-0"A2.01 G1.03

2 EXISTING SECOND FLOOR OCCUPANCY PLAN

1" = 30'-0"G1.03

3 EXISTING THIRD FLOOR OCCUPANCY PLAN

1" = 30'-0"G1.03

4 NEW THIRD FLOOR OCCUPANCY PLAN

FIRST FLOOR OCCUPANCY

SPACE AREA FACTOR OCCUPANTS

VOCATIONAL CLASSROOM 2,357 FT SQ 1:50 47 OCC

CLASSROOM 4,211 FT SQ 1:20 211 OCC

OFFICE 2,363 FT SQ 1:150 16 OCC

MECH/STORAGE 1,196 FT SQ 1:300 4 OCC

TOTAL: 278 OCC

EXISTING THIRD FLOOR OCCUPANCY

SPACE AREA FACTOR OCCUPANTS

VOCATIONAL CLASSROOM 1,938 FT SQ 1:50 39 OCC

CLASSROOM 3,222 FT SQ 1:20 161 OCC

OFFICE 7,432 FT SQ 1:150 49 OCC

MECH/STORAGE 418 FT SQ 1:300 1 OCC

TOTAL: 250 OCC

SECOND FLOOR OCCUPANCY

SPACE AREA FACTOR OCCUPANTS

VOCATIONAL CLASSROOM: 3,517 FT SQ 1:50 70 OCC

CLASSROOM: 8,606 FT SQ 1:20 430 OCC

OFFICE: 683 FT SQ 1:150 4 OCC

MECH/STORAGE: 174 FT SQ 1:300 1 OCC

TOTAL: 505 OCC

NEW THIRD FLOOR OCCUPANCY

SPACE AREA RATIO OCCUPANTS

VOCATIONAL CLASSROOM 3,416 FT SQ 1:50 68 OCC

CLASSROOM 3,222 FT SQ 1:20 161 OCC

OFFICE 6,124 FT SQ 1:150 41 OCC

MECH/STORAGE 290 FT SQ 1:300 1 OCC

TOTAL 271 OCC

OCCUPANT LOAD LEGEND

0' 10' 20' 30'

SCALE: 1" = 30'

40' 50'

PER VCC TABLE 1004.5

FUNCTION OF SPACE OCCUPANT LOAD FACTOR

PLUMBING FIXTURE TOTAL

TOTAL OCCUPANT LOAD

EXISTING 1,034 OCC 517 MEN / WOMEN

NEW 1,056 OCC 528 MEN / WOMEN

SPACE TOTAL EXIST WC TOTAL REQ'D WC

MEN 15 12

WOMEN 19 12

TOTAL EXIST LAV TOTAL REQ'D LAV

MEN 12 8

WOMEN 14 8

TOTAL EXIST DF TOTAL REQ'D DF

12 11

PER VPC TABLE 403.1

MS

SD

MS

MS

MS

SD

SD

PNLJHG

327H

LIBRARY

327D

OFF

327C

OFF

327B

OFF

327A

OFF

327E

OFF

327F

OFF

BREAK

327G

OPEN

OFFICE

STOR

LACTATION RM

300C

CORR

STOR

ELEC

MEN

COMM

CLOS

SEC

COPIER

342A

OFF

332A

CLOS

JAN

WOMEN

LOUNGE

301C

ELEV

OFF

OFF

OFF

OFF

OFF

OFF

OFF

STAIR

342D

STOR

342C

OFF

342B

OFF

SHAFT

SHAFT

D-1

D-1

D-2

D-3

D-3D-3

D-4

D-4

D-4

D-4

D-4

D-4 D-4

D-4

D-4

D-3

D-3

D-3

D-3

D-3

D-5

D-5

D-6

D-6D-7

D-7

M

3.1

7.1

K

D-3

EX DF

EX DF

STOR

D-2

D-2

D-2

D-2

D-12

D-13

D-3

D-3

D-3

D-4 L P

B

LP3A

LP3

HP3

T75

PNLJHG

9' - 0"

8' - 8 3/4"

8' - 11 5/8"

8' - 8 3/4"

327H

LIBRARY

327D

OFF

327C

OFF

327B

OFF

327A

OFF

327E

OFF

327F

OFF

BREAK

327G

OPEN

OFFICE

STOR

LACTATION RM

STOR

300C

CORR

STOR

ELEC

MEN'S

COMM

CLOS

SEC

COPIER

342A

OFF

332A

CLOS

JAN

WOMEN

LOUNGE

301C

ELEV

OFF

OFF

OFF

OFF

OFF

OFF

OFF

STAIR

342D

STOR

8' - 11 3/4"

D-10

SHAFT

SHAFT

D-9

D-9

D-9

D-9

D-9

D-9

D-9

D-8

D-8

D-8 D-8

D-8

D-8

D-8

D-8

M

3.1

7.1

K

D-8

D-8

D-8

D-10

D-11

D-11

D-11

D-11

D-11

D-11

D-11

D-11

D-11

D-11

D-2

342C

OFF

342B

OFF

D-11

D-14

D-14

2X4 LIGHT FIXTURE TO BE REMOVED

1X4 LIGHT FIXTURE TO BE REMOVED

SUPPLY DIFFUSER TO BE REMOVED

RETURN AIR GRILLE TO BE REMOVED

EXHAUST GRILLE TO BE REMOVED

CEILING SPEAKER TO BE REMOVED

CEILING MOUNTED EXIT SIGN TO BE REMOVED

2X2 ACP & GRID

TO BE REMOVED

2X4 ACP & GRID

TO BE REMOVED

SPRINKLER HEAD TO BE REMOVED

AREA OF WORK

N

NOT IN CONTRACT

NEW CONSTRUCTION

TO BE DEMOLISHED

Consultants

703.684.5994

277 S Washington St, Ste 385

Alexandria, Virginia 22314

Seal

Key Plan

Drawing

Revisions

Date

Project No.

Sheet No.

Bid Set 09/04/2026

Submission Set coleanddenny.com

Permit Electronic Approval Stamp

Mechanical, Electrical, Plumbing Engineers

Engenium Group

Fire Suppression & Fire Alarm Engineers

GHD Inc.

655 New York Ave Suite MZ02 Washington D.C. 20001

14501 George Carter Way, Suite 102 Chantilly, VA 20151

September 04, 2026

20005.30

8333 Little River Turnpike Annandale, VA 22003

PC No.: 260-B5260-007

NVCC CM Building Engineering Lab & Pantry

AD1.01

Third Floor Demolition Plan &

RCP

GENERAL DEMOLITION NOTES

1. ALL EXISTING DIMENSIONS AND CONDITIONS SHALL BE FIELD VERIFIED.

2. REQUIRED DEMOLITION SHALL NOT BE LIMITED TO THAT PORTION ON THE PLANS, BUT SHALL INCLUDE ALL NECESSARY WORK (OR INCIDENTAL THERE TO) TO COMPLETE THE WORK

IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.

3. REMOVE FLOOR, WALL, AND CEILING FINISHES AND CONSTRUCTION AS INDICATED.

4. REPAIR EXISTING CONSTRUCTION TO REMAIN WHERE MECHANICAL, PLUMBING, AND ELECTRICAL WORK IS REMOVED TO MATCH EXISTING CONSTRUCTION.

5. PREPARE REMAINING SPACE TO RECEIVE NEW CONSTRUCTION. PATCH ALL AREAS INCLUDING BUT NOT LIMITED TO WALLS AND FLOORING. ALL PATCH WORK TO MATCH EXISTING.

6. PATCH AS REQUIRED TO ACCOMMODATE NEW MECHANICAL, PLUMBING, AND ELECTRICAL WORK. REFER TO ENGINEERING DRAWINGS. ALL NEW WORK SHALL BE CONCEALED

UNLESS NOTED OTHERWISE.

7. EXIST CHROME DOOR HINGES, EXTERIOR LEVERS, AND SARGENT DOOR LOCK CORES ARE TO BE SALVAGED AND TO RETURNED TO OWNER FOR ATTIC STOCK.

8. ADDITIONAL REQUIREMENTS: THE PANTRY WORK SHALL BE PERFORMED DURING OVERNIGHT HOURS (I.E., NIGHT WORK) TO MINIMIZE DISRUPTION TO THE ADJACENT ACADEMIC

DEPARTMENT. NIGHT WORK SHALL BE PERFORMED OUTSIDE NORMAL CAMPUS OPERATING HOURS. UNLESS OTHERWISE APPROVED BY THE OWNER, NIGHT WORK MAY OCCUR

BETWEEN 6:00 PM AND 6:00 AM. ALL OTHER WORK, INCLUDING THE LABORATORY WORK, MAY BE PERFORMED DURING REGULAR WORKING HOURS AFTER 6:00AM.

1/8" = 1'-0"AD1.01

1 DEMO THIRD FLOOR PLAN

1/8" = 1'-0"AD1.01

2 DEMO THIRD FLOOR RCP

DEMOLITION RCP SYMBOLS

PHASING

KEYED DEMO NOTES

D-1 REMOVE EXIST DOOR & SALVAGE EXIST HARDWARE FOR REUSE IN NEW WORK

D-2 REMOVE EXIST DOOR & SALVAGE EXIST CHROME HINGES, EXTERIOR LEVERS, AND SARGENT DOOR

LOCK CORES FOR OWNER'S INVENTORY. COORDINATE WITH OWNER ON STORAGE LOCATION

D-3 REMOVE EXIST WALL

D-4 REMOVE EXIST LVT

D-5 REMOVE EXIST WINDOW

D-6 REMOVE EXIST MILLWORK

D-7 REMOVE EXIST BASE - TYP

D-8 REMOVE EXIST LIGHT - SEE ELEC

D-9 REMOVE EXIST ACP CEILING

D-10 REMOVE & SALVAGE EXIST EXIT SIGN FOR REUSE IN NEW WORK - SEE ELEC

D-11 REMOVE EXIST DIFFUSER - SEE MECH

D-12 REMOVE & SALVAGE DOOR FOR OWNER

D-13 REMOVE EXIST CARPET TO CONCRETE

D-14 REMOVE EXIST GYP BD CEILING

LAE

WN

O M

M O

OF

I

NI

G

RI

H V

E C TCRA

MICHAEL DETOMO

Lic. No. 15799

T

C

A

IH T 09/04/2026

5'0' 10' 20'

SCALE: 1/8" = 1'-0"

N

1. THE CONTRACTOR SHALL PROVIDE COMPLETE AND SUFFICIENT PROTECTION OF INTERIOR SPACES.

2. THE CONTRACTOR SHALL PROTECT THE OWNER'S PROPERTY BY ENSURING ROOMS AND SUITES AFFECTED BY THE WORK ARE PROPERLY SECURED

WHENEVER CONSTRUCTION TEAM MEMBERS ARE NOT PRESENT.

3. PROTECT ROOMS, SUITES, CORRIDORS, ADJACENT WALLS, DOORS, AND CEILINGS FROM DAMAGE CAUSED BY DEMOLITION. PROMPTLY REPAIR ALL

DAMAGES CAUSED BY THE WORK TO ROOMS, SUITES, CORRIDORS, ADJACENT WALLS, DOORS, AND CEILINGS AT NO COST TO THE OWNER.

4. PRIOR TO THE PERFORMANCE OF HOT WORK, THE CONTRACTOR SHALL SWEEP FLOORS CLEAN OF COMBUSTIBLES, COVER AND PROTECT THE OWNER'S

FINISHES AND ROOM CONTENTS WITH FIRE-RESISTANT WELDING BLANKETS OR OTHER FM-APPROVED FABRICS, AND SUSPEND SAFETY BLANKETS

BENEATH WORK TO COLLECT SPARKS.

GENERAL PROTECTION NOTES

MS

MS

NOT IN CONTRACT

AREA OF WORK

ITEM PROVIDED BY

OWNER

LACTATION RM

300C

CORR

STOR

ELEC

MEN

COMM

CLOS

SEC

JAN

WOMEN

301C

ELEV

OFF

OFF

OFF

OFF

OFF

OFF

OFF

STAIR

342D

STOR

STOR

EX DF

EX DF

REF REF

ENG LAB

X

LOUNGE

DUAL

MANUAL

FAUCET

CONTROL

A4.01

A4.01

A4.01A1.01

A4.01A1.01

PANTRY

CR

CR

A4.01A1.01

C R

JUNCTION

BOX -

SEE ELEC

SHAFT

SHAFT

342C

OFF

342B

OFF

BUILT IN

SHELVES -

(POWER

TOOL

STORAGE)

A4.01

327A

327B

AA

EYEWASH -

SEE PLUMB

1A

342A

OFF

A4.01

1A

B E

C G

AA

AA

A

AA

AA

A1

I

H

H

H

H

D

A4.01

K

F

S

I

I

J

L

P

O

P

P

Q Q Q Q

Q

Q

Q Q Q Q

Q Q Q Q

Q

Q

Q Q Q Q

Q1

C1

U

A4.022

R S

N

M

V

Q1 Q1 Q1

Q1 Q1 Q1 Q1

A1

A1A1 A1

C

'-1

'-4

/4

21'-6 7/8" 5'-5 1/2" 5'-11 3/4"

'-0

/8

7'-10 3/8"

21'-8 1/8"

'-9

/8

1'-7 5/8"

1'-11 1/2"

'-6

/8

1'-9 1/2" 13'-5"

5'-11 1/8" 7'-9 3/8"

'-8

'-5

/2

'-5

/4

'-1

/2

'-2

'-7

/8

Z

L X

'-8

Q2

Q2

T

Y

I

Y

A4.02 1

TH

T H

TH

LP

B

LP3A

LP3

HP3

T75

9' - 0"

LACTATION RM

STOR

ELEC

MEN'S

COMM

CLOS

SEC

JAN

WOMEN

301C

ELEV

OFF

OFF

OFF

OFF

OFF

OFF

OFF

STAIR

342D

STOR

ENG LAB

STOR

PANTRY

8' - 11 3/4"

AV

EXTRON

PVM 220

WIRELESS

EQUIPMENT

SHAFT

SHAFT

PATCH

CEILING TO

MATCH

EXISTING

342C

OFF

342B

OFF

9' - 0"

342A

OFF

LOUNGE

W

W

X'-XX" CEILING HEIGHT

SUPPLY DIFFUSER (SEE MECH)

CEILING MOUNTED EXIT SIGN (SEE ELEC)

RETURN AIR GRILLE (SEE MECH) SPRINKLER HEAD (SEE FP)

2X4 LED LIGHT FIXTURE (SEE ELEC) SMOKE DETECTOR (SEE ELEC)

2X4 ACP & GRID

CEILING RECEPTACLE (SEE ELEC)

AREA OF WORK

N

Consultants

703.684.5994

277 S Washington St, Ste 385

Alexandria, Virginia 22314

Seal

Key Plan

Drawing

Revisions

Date

Project No.

Sheet No.

Bid Set 09/04/2026

Submission Set coleanddenny.com

Permit Electronic Approval Stamp

Mechanical, Electrical, Plumbing Engineers

Engenium Group

Fire Suppression & Fire Alarm Engineers

GHD Inc.

655 New York Ave Suite MZ02 Washington D.C. 20001

14501 George Carter Way, Suite 102 Chantilly, VA 20151

September 04, 2026

20005.30

8333 Little River Turnpike Annandale, VA 22003

PC No.: 260-B5260-007

NVCC CM Building Engineering Lab & Pantry

A1.01

Third Floor Plan, RCP, Furniture & Equipment Schedule

GENERAL NEW WORK NOTES

1. DIMENSIONS ARE TO FINISH FACE OF CONSTRUCTION UNLESS OTHERWISE INDICATED.

2. OUTSIDE OF DOOR JAMBS TO BE 4" FROM WALL INTERSECTION UNLESS OTHERWISE

INDICATED.

3. PROVIDE NON-COMBUSTIBLE OR FIRE RETARDANT TREATED WOOD BLOCKING IN PARTITIONS

WHERE REQUIRED TO SUPPORT WALL MOUNTED ITEMS SUCH AS DIGITAL MEDIA PLAYERS,

DRY ERASE BOARDS, SMART BOARDS, ETC. SEE FLOOR PLAN. CONTRACTOR SHALL

COORDINATE WITH THE OWNER'S REPRESENTATIVE FOR LOCATIONS OF BLOCKING. THE

OWNER SHALL PROVIDE THESE WALL MOUNTED DEVICES.

4. OWNER SHALL PROVIDE AND INSTALL FURNITURE.

5. ADDITIONAL REQUIREMENTS: THE PANTRY WORK SHALL BE PERFORMED DURING OVERNIGHT

HOURS (I.E., NIGHT WORK) TO MINIMIZE DISRUPTION TO THE ADJACENT ACADEMIC

DEPARTMENT. NIGHT WORK SHALL BE PERFORMED OUTSIDE NORMAL CAMPUS OPERATING

HOURS. UNLESS OTHERWISE APPROVED BY THE OWNER, NIGHT WORK MAY OCCUR BETWEEN

6:00 PM AND 6:00 AM. ALL OTHER WORK, INCLUDING THE LABORATORY WORK, MAY BE

PERFORMED DURING REGULAR WORKING HOURS AFTER 6:00AM.

1/8" = 1'-0"A1.01

2 THIRD FLOOR RCP

PHASING

1/8" = 1'-0"A1.01

1 THIRD FLOOR PLAN

RCP SYMBOLS

FURNITURE & EQUIPMENT SCHEDULE

FURNITURE

QUANTITY ROOM # PROCUREMENT INSTALLATION UTILITY COMMENTSMARK ITEM MAKE/MODEL SIZE (W x D x H)

A ADJUSTABLE HEIGHT WORK BENCH BT-305M.P W/ CASTERS 60" x 30" x ADJ (27" - 35.5") 10 327 OWNER OWNER

A1 ADA FIXED HEIGHT WORK BENCH BT-305M-29 W/ CASTERS 60" X 30" X 29" 5 327 OWNER OWNER

B WALL WORKSTATION CBL-144-CUST 144" x 25.5" x 34" 1 327 OWNER OWNER

C CUSTOM WALL WORK BENCH CBL-72.M-CUST 72" X 24" X 34" 2 327 OWNER OWNER

C1 CUSTOM WALL WORK BENCH CBL-120-3M 126" x 24" x 34" 1 327 OWNER OWNER

D MOBILE TALL STORAGE CABINET WC3-3674.P 36" x 24" x 74.5" 1 327 OWNER OWNER

E MOBILE DEMONSTRATION TABLE BT-368M-1 96" x 36" x ADJ (27" - 35.5") 1 327 OWNER OWNER

F TOOL SHELVING ULINE H-4814 84" x 24" x 60" 1 327 OWNER OWNER NON-COMBUSTIBLE

G LASER CUTTER UNIVERSAL LASER SYSTEMS VLS3.60DT + AD BASE 1 ORACLE BASE 1 327 OWNER OWNER ELEC

H 3D PRINTERS ORIGINAL PRUSA MK4 21.5" x 28" x 21" 4 327 OWNER OWNER ELEC OWNER PROCURES ENCLOSURE & FILTRATION SYSTEM BY MANUFACTURER

I TOOL BOX HUSKY 27 IN 1-DRAWER 3-DOOR PROJECT CENTER 27" x 19" x 54" 4 327 OWNER OWNER ELEC

J DRILL PRESS W/ FLOOR STAND DAYTON BENCH DRILL PRESS: BELT, 120V AC, FIXED SPEED, 650 RPM – 3,070 RPM, 10 IN SWING, 5 IN 1/3 HP 8.25" x 13.5" x 27.5" 1 327 GC GC ELEC GC CONNECT TO DUST COLLECTOR

K DUST COLLECTOR LAGUNA B|FLUX 15" x 29" x 50" 1 327 OWNER GC ELEC FOR DRILL PRESS & BAND SAW

L REFRIGERATOR SAMSUNG RS27T5200SR 36" x 33.5" x 70" 2 340 GC GC ELEC GC CONNECTION & ADA COMPLIANCE

M MICROWAVE 1 340 OWNER OWNER ELEC

N GARBAGE DISPOSAL 1 340 GC GC ELEC

O PANTRY TABLE LELAND FAST TABLE 42" X 42" 29" 1 340 OWNER OWNER

P PANTRY CHAIRS LELAND SLAM SLED BASE CHAIR 22.5" X 20.75" X 31.75" 4 340 OWNER OWNER

Q STOOL KI STRIVE TASK STOOL 27.5" X 27.5" X ADJ (37.75" - 48") 20 327 OWNER OWNER

Q1 STOOL W/ BACKING KI STRIVE TASK CHAIR 27.5" X 27.5" X ADJ (32.75" - 37.75") 8 327 OWNER OWNER

Q2 CHAIR K1 STRIVE ADA ARM CHAIR 25" X 21.75" X 32.5" 2 327 OWNER OWNER

R EYEWASH SAFETY MANUFACTURING MODEL S2340 1 327 GC GC WATER

S SINK KOHLER K-3894-4 18" x 20" 2 340 / 327 GC GC WATER

T LECTURN TRIBUTAIRE LECTURN - PNEUMATIC HEIGHT ADJUSTABLE 22" X 19" X ADJ (34" - 48") 1 327 OWNER OWNER ELEC

U ADA DESK PIVOT PREMIER WORKSTATION - PNEUMATIC HEIGHT ADJUSTABLE 48" X 30" X ADJ (28.5" - 42") 1 327 OWNER OWNER

V BAND SAW WITH FLOOR STAND DEWALT DWS715 1 327 OWNER GC ELEC GC CONNECT TO DUST COLLECTOR

W LASER PROJECTOR POWERLITE L690SU 6200-LUMEN SHORT THROW WUXGA 3LCD LASER PROJECTOR 18" X 17.7" X 9" 2 327 OWNER OWNER ELEC

X INTERACTIVE PROJECTOR BOARD MOORECO 2G5KX-XX 120" X 1" X 60" 2 327 OWNER OWNER ELEC

Y COMPUTER 2 327 OWNER OWNER

Z TEACHER CHAIR NAVIGATOR AIR TASK CHAIR 26.5" X 26.5" X ADJ (33.5" - 38.5") 1 327 OWNER OWNER

5'0' 10' 20'

SCALE: 1/8" = 1'-0"

N

LAE

WN

O M

M O

OF

I

NI

G

RI

H V

E C TCRA

MICHAEL DETOMO

Lic. No. 15799

T

C

A

A4.01A1.01

A4.01A1.01

REFRIGERATORS BY

GC

3'-0"3'-0"

2' -6

2'

-2

2' -1

0"

VINYL BASE

OUTLETS - SEE ELEC

SINK & FAUCETS - SEE

SPEC, ELEC & PLUMB

STAINLESS STEEL

EDGE METAL PROFILE

2'-6"2'-6"

O

F O

PE

RA

B

LE

P

AR

TS

'-1

" M

AX

T O

T O

P

12 3/4"

M

IN

L L

2'-0 3/4" 1'-6" 30" MIN

CORNER BIFOLD

CABINET

PL-1

PL-2

SSM-1

M

IN

M

AX

P

ER

A D

A 2'

-2

2' -6

O

PE

RA

BL

E

PA

RT

S

" M

AX

T O

T O

P O

F

STAINLESS

STEEL EDGE

METAL

PROFILE

A4.01A1.01

2'-6"

2'-0" 2'-0"

M

IN

4"

SOLID

SURFACING

MATERIAL

COUNTERTOP

& BACKSPLASH

VINYL

BASE

2'-6"

PL-1

PL-2

CORNER BIFOLD

CABINET

SSM-1

M

12 3/4"

24" MAX

SSM-1

S

2'-0"

7'-9 3/8" GCVIF

A4.01A1.01

VINYL BASE

SOLID SURFACING MATERIAL

COUNTERTOP & BACKSPLASH

2' -2

1' -4

/2

4"

1' -1

/2

2' -6

M

IN

2'-0"

EYEWASH

END PANEL

PL-1

R

PL-2

4"

F O

PE

RA

B

LE

P

AR

TS

" A

FF

M

AX

T

O T

O P

EYEWASH AND DRENCH SHOWER

STATIONS MUST BE INSTALLED IN A

WELL-LIT AREA AND IDENTIFIED WITH

A HIGHLY VISIBLE SAFETY SIGN PER

ANSI/ISEA Z358.1-2014 (R2020)

PROVIDE SIGNAGE ON HOW TO

USE EYEWASH STATION

2' -1

0"

SOLID SURFACING MATERIAL

COUNTERTOP &

BACKSPLASH

WHITE MELAMINE

INTERIOR ADJUSTABLE

SHELVING & FINISH, TYP

PLASTIC LAMINATE

WALL CABINET W/

SOFT CLOSER HINGES

LINEAR PULLS, TYP

FRT WD

BLOCKING,

TYP

CONT

CLEAT

ANCHORED

TO WALL

3/4" PLASTIC LAMINATE

PANEL

PLASTIC LAMINATE

SOLID END PANEL EACH SIDE

UNDERMOUNT SINK - SEE

PLUMBING

PROVIDE 1 1/2" OFFSET CUT

AROUND SINK TO

ALLOW SLIDING REMOVAL OF

PLASTIC LAMINATE PANEL

VINYL BASE

SILICON SEALANT

AROUND PERIMETER

24" MAX

2' -2

2'

-6

M

IN

2' -1

0"

APRON

12 3/4"

PL-1

PL-2

PL-2

M

IN

4"

8" MIN

11" MIN

M

IN PROVIDE

KNEE

CLEARANCE

PER ADA

6" MAX

WHITE MELAMINE

INTERIOR ADJUSTABLE

SHELVING & FINISH, TYP

PLASTIC LAMINATE

WALL CABINET W/ SOFT

CLOSER HINGES

LINEAR PULLS, TYP

SILICON SEALANT

AROUND PERIMETER

SOLID SURFACING

MATERIAL

COUNTERTOP &

BACKSPLASH

LINEAR PULLS, TYP

PLASTIC LAMINATE

BASE CABINET

DOORS W/ SOFT

CLOSER HINGES

WHITE MELAMINE

INTERIOR ADJUSTABLE

SHELVING & FINISH,

TYP

VINYL BASE

FRT WD

BLOCKING,

TYP

DRAWER W/ EXTENSION

SLIDES & SOFT CLOSER

PROVIDE

BASE

FRAMING,

TYP

2' -6

12 3/4"

M

IN

2' -1

0" 2'

-2

4"

24" MAX

PL-1

PL-2

SSM-1

LASER CUTTER

BY OWNER

3' -0

6'-0"

PE

RA

B

LE

P

AR

TS

3' -1

0"

AX

T O

T O

P O

F

21'-6 7/8"

4'-9 3/8"2'-4 3/4" 2'-4 3/4"6'-0"

AA

2' -0

4'

-0

MODULAR

STORAGE BY

OWNER, TYP

M

AX

P

ER

A D

A

5'-5 1/2"

VINYL BASE

3'-0" 6'

-2

/2

Y

3'-0"

CC

G

D

3'-0" 3'-0" 3'-0" 2'-9"2'-0"

COMPUTER BY

OWNER

THERMOSTAT

44" O.C.

AFF - SEE

MECH

4"

3' -0

7'-10 3/8"

2' -1

/2

2'

-1

/2

1' -9

6' -0

1/

2"

TY

P

84" x 24" x 60"

NON-COMBUSTIBLE

STORAGE SHELVES BY

OWNER

VINYL BASE

F

11'-0 1/4"

MODULAR

STORAGE BY

OWNER

M

AX

P

ER

A D

A

1/

2"

VINYL BASE

C1

3'-0" 3'-0" 3'-0"

RA

B

LE

P

AR

TS

" M

AX

T

O T

O P

O F

1'-0 1/8"

Consultants

703.684.5994

277 S Washington St, Ste 385

Alexandria, Virginia 22314

Seal

Key Plan

Drawing

Revisions

Date

Project No.

Sheet No.

Bid Set 09/04/2026

Submission Set coleanddenny.com

Permit Electronic Approval Stamp

Mechanical, Electrical, Plumbing Engineers

Engenium Group

Fire Suppression & Fire Alarm Engineers

GHD Inc.

655 New York Ave Suite MZ02 Washington D.C. 20001

14501 George Carter Way, Suite 102 Chantilly, VA 20151

September 04, 2026

20005.30

8333 Little River Turnpike Annandale, VA 22003

PC No.: 260-B5260-007

NVCC CM Building Engineering Lab & Pantry

A4.01

Interior Elevations & Millwork Details

0' 6" 1' 2'

SCALE: 1" = 1'-0"

1/2" = 1'-0"A1.01 A4.01

2 ENG LAB SINK & EYEWASH ELEVATION

1/2" = 1'-0"A1.01 A4.01

8 PANTRY WEST ELEVATION

1/2" = 1'-0"A1.01 A4.01

7 PANTRY SOUTH ELEVATION

1" = 1'-0"A1.01 A4.01

4 MILLWORK SECTION

1" = 1'-0"A1.01 A4.01

5 MILLWORK SECTION

0' 1' 2' 4'6"

SCALE: 1/2" = 1'-0"

1/2" = 1'-0"A1.01 A4.01

3 ENG LAB WEST ELEVATION

1/2" = 1'-0"A1.01 A4.01

1 POWER TOOL STORAGE

1/2" = 1'-0"A1.01 A4.01

6 ENG LAB EAST ELEVATION

LAE

WN

O M

M O

OF

I

NI

G

RI

H V

E C TCRA

MICHAEL DETOMO

Lic. No. 15799

T

C

A

" M

IN

2'

-6

2' -2

M

AX

P

ER

A

D A

I

J

K

II

V

TOOLBOX BY

OWNER, TYP

DUST COLLECTOR

BY OWNER

BAND SAW BY

OWNER

DRILL PRESS &

STAND BY OWNER

STAINLESS STEEL

EDGE METAL PROFILE

SOLID SURFACING

MATERIAL

COUNTERTOP &

BACKSPLASH

PL-1

SSM-1

VINYL BASE

S

4"

M

AX

TY

P

M

AX

P

ER

A D

A

INTERACTIVE PROJECTOR BD

10'-0" 10'-0" 17'-8 3/4"

MODULAR

STORAGE BY

OWNER, TYP

VINYL BASE

X X H

Y B

C

3D PRINTERS

I

TOOLBOX BY

OWNER

COMPUTER

BY OWNER

U

Z

T

JUNCTION BOX 44"

O.C. AFF - SEE ELEC

M

A X, T

YP

2' -6

5'

-0

M

IN

H H H

RA

B

LE

P

AR

TS

3' -1

0" M

AX

T

O T

O P

O F

THERMOSTAT 44"

O.C. AFF - SEE MECH

ACP & GRID

EXISTING STL JOIST

EXISTING MTL DECKEXISTING ROOF

2"X1" SLOTTED MOUNTING

CHANNEL (X2) @ 10" OC

2" X 1" X 48" SLOTTED

MOUNTING CHANNEL

(X2) @ 10" OC

1/2" THREADED

ROD, EA

CHANNEL (X4)

1/2" THREADED ROD,

EA CHANNEL (X4)

CEILING CORD AND REEL

84" MAX AFF, TYP

ACP & GRID

EXISTING STL JOIST

EXISTING MTL DECKEXISTING ROOF

2"X1" SLOTTED MOUNTING

CHANNEL (X2) @ 10" OC

2" X 1" X 48" SLOTTED

MOUNTING CHANNEL

(X2) @ 10" OC1/2" THREADED ROD,

EA CHANNEL (X4)

1/2" THREADED ROD,

EA CHANNEL (X4)

PROJECTOR BY OWNER

PROJECTOR MOUNT BY

OWNER

Consultants

703.684.5994

277 S Washington St, Ste 385

Alexandria, Virginia 22314

Seal

Key Plan

Drawing

Revisions

Date

Project No.

Sheet No.

Bid Set 09/04/2026

Submission Set coleanddenny.com

Permit Electronic Approval Stamp

Mechanical, Electrical, Plumbing Engineers

Engenium Group

Fire Suppression & Fire Alarm Engineers

GHD Inc.

655 New York Ave Suite MZ02 Washington D.C. 20001

14501 George Carter Way, Suite 102 Chantilly, VA 20151

September 04, 2026

20005.30

8333 Little River Turnpike Annandale, VA 22003

PC No.: 260-B5260-007

NVCC CM Building Engineering Lab & Pantry

A4.02

Interior Elevations & Details

0' 1' 2' 4'6"

SCALE: 1/2" = 1'-0"

1/2" = 1'-0"A1.01 A4.02

2 ENG LAB NORTH ELEVATION

1/2" = 1'-0"A1.01 A4.02

1 ENG LAB SOUTH ELEVATION

LAE

WN

O M

M O

OF

I

NI

G

RI

H V

E C TCRA

MICHAEL DETOMO

Lic. No. 15799

T

C

A

IH T 09/04/2026

1" = 1'-0"A4.02

3 ELEC RECEPTACLE MOUNT

0' 6" 1' 2'

SCALE: 1" = 1'-0"

1" = 1'-0"A4.02

4 PROJECTOR CEILING MOUNT DETAIL

3 5/8" METAL STUDS O.C.

5/8" GYPSUM WALL BOARD

BASE

FINISH FLOOR

EXISTING STRUCTURE

ABOVE

ACP OR GWB CEILING

WHERE INDICATED

BATT INSULATION

ACOUSTICAL SEALANT

4 7/8"

2"

SEE PARTITION TYPES

SEE PARTITION TYPE

CONTINUOUS PERIMETER

SEALANT EACH SIDE

H.M. FRAME

DOOR

EXIST H.M. FRAME

NEW DOOR GC VIF

EXIST PARTITION

2"

SEE PARTITION TYPE

CONTINUOUS

PERIMETER

SEALANT EACH SIDE

DOOR

H.M. FRAME CARD READER

DOOR

JAMB BEYOND

LVTEXIST. LVT FLOORING

EXIST WALL

H.M. FRAME

DOOR

DOOR OPERATOR CARD READER

CONCEALED JBOX & CONDUIT

CONTINUOUS

PERIMETER SEALANT

EACH SIDE

2"

3 5/8" METAL STUDS 16" O.C.

5/8" GYPSUM WALL BOARD

BASE

FINISH FLOOR

EXISTING STRUCTURE

ABOVE

ACP OR GWB CEILING

WHERE INDICATED

BATT INSULATION

ACOUSTICAL SEALANT

4 7/8"

3 1/2" SOUND BATT INSUL

EXISTING WALL

1A

BACKER ROD & SEALANT

EACH SIDE

ALUM FRAME

1/4" TEMPERED GLASS

W/ GLAZING TAPE

FINISH END OF DRYWALL

BLOCKING

ALIGN

SEE PARTITION TYPES

5"

1/2" GYPSUM WALL

BOARD EACH SIDE

EXISTING FINISH FLOOR

EXISTING SUSPENDED

CEILING

3 5/8" METAL STUDS 16" O.C.

HM DOOR - DOOR HARDWARE SHALL

PROVIDE FREE EGRESS AT ALL TIMES

HM FRAME

NOTE: TEMPORARY CONSTRUCTION PARTITION SHALL BE ERECTED

DURING CONSTRUCTION AND REMOVED BEFORE OCCUPANCY

T

1 HR FIRE RESISTANT

RATING PER UL V438 ON

G0.03

EXISTING STRUCTURE

ABOVE

Consultants

703.684.5994

277 S Washington St, Ste 385

Alexandria, Virginia 22314

Seal

Key Plan

Drawing

Revisions

Date

Project No.

Sheet No.

Bid Set 09/04/2026

Submission Set coleanddenny.com

Permit Electronic Approval Stamp

Mechanical, Electrical, Plumbing Engineers

Engenium Group

Fire Suppression & Fire Alarm Engineers

GHD Inc.

655 New York Ave Suite MZ02 Washington D.C. 20001

14501 George Carter Way, Suite 102 Chantilly, VA 20151

September 04, 2026

20005.30

8333 Little River Turnpike Annandale, VA 22003

PC No.: 260-B5260-007

NVCC CM Building Engineering Lab & Pantry

A5.01

Partition Types & Door & Window Detail

0' 1' 2'6"

SCALE: 1 1/2" = 1'-0"

1 1/2" = 1'-0"G1.02 A5.01

1 PARTITION TYPES

1 1/2" = 1'-0"A6.01 A5.01

2 HEAD DETAIL

1 1/2" = 1'-0"A6.01 A5.01

3 HEAD DETAIL

1 1/2" = 1'-0"A6.01 A5.01

5 JAMB DETAIL

1 1/2" = 1'-0"A6.01 A5.01

7 THRESHOLD DETAIL

1 1/2" = 1'-0"A6.01 A5.01

6 JAMB DETAIL

1 1/2" = 1'-0"A6.01 A5.01

4 WINDOW HEAD/JAMB DETAIL

LAE

WN

O M

M O

OF

I

NI

G

RI

H V

E C TCRA

MICHAEL DETOMO

Lic. No. 15799

T

C

A

A A

A5.016 / A5.015 /

A5.012 / A5.013 /

A5.017 / A5.017 /

327A

327B

M A

X

M A

X

LACTATION RM

300C

CORR

STOR

ELEC

MEN

COMM

CLOS

SEC

JAN

WOMEN

301C

ELEV

OFF

OFF

OFF

OFF

OFF

OFF

OFF

STAIR

342D

STOR

342C

ASSIST DIV

CHAIR

342B

ASSIST DIV

CHAIR

EX DF

EX DF

PANTRY

ENG LAB

LOUNGE

LVT-1

LVT-2

PTD-3

PTD-1

PTD-1

PTD-1

PTD-1

PTD-1

PTD-1

PTD-1

PTD-1

PTD-1

PTD-1

342A

OFFPTD-2

327A

327B

A A

CR

CR

C R

STOR

NOT IN CONTRACT

AREA OF WORK

ITEM PROVIDED BY

OWNER

A

6'-0"

3' -0

A5.014 /

A5.014 /

A5.014 /

Consultants

703.684.5994

277 S Washington St, Ste 385

Alexandria, Virginia 22314

Seal

Key Plan

Drawing

Revisions

Date

Project No.

Sheet No.

Bid Set 09/04/2026

Submission Set coleanddenny.com

Permit Electronic Approval Stamp

Mechanical, Electrical, Plumbing Engineers

Engenium Group

Fire Suppression & Fire Alarm Engineers

GHD Inc.

655 New York Ave Suite MZ02 Washington D.C. 20001

14501 George Carter Way, Suite 102 Chantilly, VA 20151

September 04, 2026

20005.30

8333 Little River Turnpike Annandale, VA 22003

PC No.: 260-B5260-007

NVCC CM Building Engineering Lab & Pantry

A6.01

Finish Plan & Schedule

1/4" = 1'-0"A6.01

1 DOOR ELEVATION

NUMBER NAME FLOOR BASE CEILING

WALLS

COMMENTSNORTH EAST SOUTH WEST

327 ENG LAB LVT-1 RB 2' X4' ACP PTD-3 PTD-1 PTD-1 PTD-1 LVT ACCENT - SEE ELEVATIONS

340 PANTRY LVT-2 RB 2' X4' ACP PTD-1 PTD-1 PTD-2 PTD-1 LVT ACCENT - SEE ELEVATIONS

FINISH SCHEDULE

DOOR FRAME

HARDWARE

LOCKSET

FUNCTION COMMENTSDOOR # SIZE TYPE MATERIAL FINISH MATERIAL FINISH HEAD JAMB THRESHOLD

327A 3'-0" x 7'-0" x 1 3/4" W/ NARROW LITE A SCW STAIN HM PTD 3/A5.01 6/A5.01 7/A5.01 1.0 EDA ARMOR PLATE ON PUSH SIDE

327B 3'-0" x 7'-0" x 1 3/4" W/ NARROW LITE A SCW STAIN HM PTD 2/A5.01 5/A5.01 7/A5.01 1.0 EDA ARMOR PLATE ON PUSH SIDE

340 3'-0" x 7'-0" x 1 3/4" W/ NARROW LITE A SCW STAIN HM PTD 3/A5.01 6/A5.01 7/A5.01 2.0 EDA

DOOR SCHEDULE

1/8" = 1'-0"A6.01

3 THIRD FLOOR PLAN - FINISH PLAN

5'0' 10' 20'

SCALE: 1/8" = 1'-0"

PHASING

N

FINISH ABBREVIATIONS

ACP ACOUSTICAL CEILING PANEL

LVT LUXURY VINYL TILE

PL PLASTIC LAMINATE

PTD PAINTED

RB RESILIENT BASE

SSM SOLID SURFACING MATERIAL

ACP ARMSTRONG OPTIMA

LVT-1 PATCRAFT "SAND DOLLAR"

LVT-2 PATCRAFT "WILLOW"

PL-1 WILSONART "MAPLE PB NUTMEG" 8281K-05

PL-2 WILSONART "DOVE GREY" D92-60

PTD-1 SW 7035 "AESTHIC WHITE"

PTD-2 SW 2812 "ROOKWOOD JADE"

PTD-3 SW 6460 "KALE GREEN"

RB JOHNSONITE "24 GREY HAZE" - TYP

SSM-1 WILSONART "CARRARA EMPORIO" 9909SS

FINISH LIST

0' 2' 4' 8'

SCALE: 1/4" = 1'-0"

1/4" = 1'-0"A6.01

2 WINDOW ELEVATION

WINDOW SCHEDULE

WINDOW FRAME

GLAZING TYPE COMMENTSNUMBER TYPE SIZE SILL HEIGHT MATERIAL FINISH HEAD JAMB

1 A 36" x 72" 4' - 0" ALUM ANODIZED ALUM 4/A5.01 4/A5.01 TEMPERED GLASS

2 A 36" x 72" 4' - 0" ALUM ANODIZED ALUM 4/A5.01 4/A5.01 TEMPERED GLASS

SET 1.0

DOORS: 327A, 327B

3 HINGE, FULL MORTISE TA2714 NRP US26D MK

1 ACCESS CONTROL CYL LOCK IN100-10XG77 BIPS B GP LC US26D SA*

1 CYLINDER MATCH/EXPAND FACILITY EXISTING OT

1 ARMOR PLATE K1050 34" HIGH CSK US32D RO

1 WALL STOP 403 US26D RO

1 CARD READER APERIO IN100 SA

2 SILENCER 4040 (TO SUIT) LC

OPERATIONAL DESCRIPTION: DOORS ARE NORMALLY CLOSED AND LOCKED. PRESENTING A VALID CARD TO THE CARD READER ON THE LOCKSET WILL UNLOCK OUTSIDE LEVER ALLOWING ENTRY. ENTRY ALSO BY KEY IN

CYLINDER. FREE EGRESS AT ALL TIMES.

*DOOR HARDWARE CORES PROVIDED BY OWNER.

DOOR HARDWARE SET

LAE

WN

O M

M O

OF

I

NI

G

RI

H V

E C TCRA

MICHAEL DETOMO

Lic. No. 15799

T

C

A

IH T 09/04/2026

SET 2.0

DOORS: 340

3 HINGE, FULL MORTISE TA2714 NRP US26D MK

1 ACCESS CONTROL CYL LOCK IN100-10XG77 BIPS B GP LC US26D SA*

1 CYLINDER MATCH/EXPAND FACILITY EXISTING OT

1 WALL STOP 403 US26D RO

1 KEYPAD 40KNKS-02-000000 BLK HI

1 SILENCER 4040 (TO SUIT) LC

OPERATIONAL DESCRIPTION: DOORS ARE NORMALLY CLOSED AND LOCKED. PRESENTING A VALID CARD TO THE CARD READER ON THE LOCKSET WILL UNLOCK OUTSIDE LEVER ALLOWING ENTRY. ENTRY ALSO BY KEY IN

CYLINDER. FREE EGRESS AT ALL TIMES.

*DOOR HARDWARE CORES PROVIDED BY OWNER.

1. REPLACEMENT OF EXISTING FAN POWERED VAV BOXES AND PROVIDE

NEW DUCTWORK AND PIPING CONNECTIONS.

2. PROVIDE NEW AIR DEVICES FOR ALL SPACES.

3. PROVIDE NEW MECHANICAL INFRASTRUCTURE TO SUPPORT NEW

LAUNDRY ROOM.

GENERAL MECHANICAL SCOPE OF WORKMECHANICAL LEGEND

MANUAL VOLUME DAMPER

FIRE DAMPER WITH ACCESS DOOR

FIRE/SMOKE DAMPER WITH ACCESS DOOR

2-POSITION AUTOMATIC CONTROL DAMPER

MODULATING AUTOMATIC CONTROL DAMPER

RETURN OR EXHAUST AIR FLOW

SUPPLY AIR FLOW

TEMPERATURE SENSOR OR THERMOSTAT

CARBON DIOXIDE SENSOR

DUCT-MOUNTED SMOKE DETECTOR

T

C

DOOR UNDER-CUT

SMOKE DAMPER WITH ACCESS DOOR

EQUIPMENT TAGS

INDOOR

LARGE UNDERLINED TEXT REFERS

TO EQUIPMENT DESIGNATIONS;

SEE EQUIPMENT SCHEDULES FOR

PROJECT REQUIREMENTS

SMALLER TEXT BELOW PROVIDES

ADDITIONAL INFORMATION

RELATIVES TO SPECIFIC

EQUIPMENT

EQUIP-1

AIR DEVICE TAGS

AIRFLOW IN CFM

AAA

SD-X GRILLE, REGISTER, OR DIFFUSER DESIGNATIONS

LOCATED IN AIR DEVICE SCHEDULE

RG-X GRILLE, REGISTER, OR DIFFUSER DESIGNATIONS

LOCATED IN AIR DEVICE SCHEDULE

Ø

NOT BALANCED TO SET AIRFLOW

PHASE SYMBOLS & ABBREVIATIONS

(E) EXISTING TO REMAIN

(R)

(X)

EXISTING TO BE RELOCATED

EXISTING TO BE DEMOLISHED

CONNECT TO EXISTING

POINT OF DISCONNECT

LINEWEIGHT LEGEND

NEW WORK

DEMOLITION WORK

EXISTING TO REMAIN

DRAFTING SYMBOLS

REVISION NUMBER

REVISION CLOUD

OA

RISER TYPE

RISER DESIGNATION

PLAN / SECTION / DETAIL DESIGNATION

SCALE: 1/8" = 1'-0"

MECHANICAL FIRST FLOOR PLAN

PLAN / SECTION / DETAIL DESCRIPTION

SHEET NUMBER

SECTION DESIGNATION

PLAN / SECTION / DETAIL SCALE

SHEET NUMBER

ENLARGED PLAN CALLOUT DESIGNATION

VALVE

PIPE UNION

MECHANICAL PIPING LEGEND

TOP TAKE-OFF

BOTTOM TAKE-OFF

CHECK VALVE OR BACKWATER VALVE

Y-STRAINER

AUTOMATIC VALVE, 2-POSITION ATC ACTUATOR

AUTOMATIC VALVE, MODULATING ATC ACTUATOR

3-WAY VALVE, 2-POSITION ATC ACTUATOR

3-WAY VALVE, MODULATING ATC ACTUATOR

PRESSURE GAGE WITH GAGE COCK

TEMPERATURE SENSOR WITH GAGE COCK

PRESSURE / TEMPERATURE WELL

AUTOMATIC AIR VENT WITH ISOLATION VALVE

FLEXIBLE CONNECTION

DIRECTION OF FLOW IN PIPE

MANUAL ISOLATION VALVE

VACUUM BREAKER

END CAP

PIPE RISE

PIPE DROP

PIPE BREAK

WATER HAMMER ARRESTOR

HEAT TRACE

DUCTWORK LEGEND

ROUND DUCT UP

(SUPPLY / RETURN / EXHAUST)

RECTANGULAR DUCT UP

(SUPPLY / RETURN / EXHAUST)

ROUND DUCT DOWN

(SUPPLY / RETURN / EXHAUST)

RECTANGULAR DUCT DOWN

(SUPPLY / RETURN / EXHAUST)

DUCT (PLAN VIEW)

(SUPPLY / RETURN / EXHAUST)

EXISTING DUCT TO BE REMOVED

(SUPPLY / RETURN / EXHAUST)

FLEXIBLE DUCTWORK

RISE

DROP

RISE IN DUCT

(SUPPLY / RETURN / EXHAUST)

DROP IN DUCT

(SUPPLY / RETURN / EXHAUST)

STANDARD RADIUS ELBOW

(INSIDE RADIUS = DUCT WIDTH)

(SUPPLY / RETURN / EXHAUST)

SQUARE ELBOW

(DOUBLE WIDTH TURNING VANES)

90° BRANCH TAKE-OFF

45° RADIUS ELBOW

(SUPPLY / RETURN / EXHAUST)

SUPPLY DIFFUSER WITH ROUND DUCT

RUNOUT & FLEXIBLE CONNECTION

SUPPLY DIFFUSER WITH ROUND DUCT

RUNOUT & HARD CONNECTION

DUCT MOUNTED CEILING DIFFUSER

WITH BRANCH TAKE-OFF

LINEAR DIFFUSER WITH ROUND DUCT

RUNOUT & FLEXIBLE CONNECTION

LINEAR DIFFUSER WITH ROUND DUCT

RUNOUT & HARD CONNECTION

OPEN ENDED DUCT (PLAN VIEW)

(RETURN / EXHAUST / TRANSFER)

DUCT WITH INTERNAL ACOUSTIC

SOUND LINING

A

A AMPERE

AC AIR CONDITIONING

AD ACCESS DOOR

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

ARCH ARCHITECT

ATC AUTOMATIC TEMPERATURE CONTROLS

B

BHP BRAKE HORSEPOWER

BOD BASIS OF DESIGN

BOD BOTTOM ELEVATION OF DUCT

BOP BOTTOM ELEVATION OF PIPE

C

CD CONDENSATE DRAIN

CFM CUBIC FEET PER MINUTE

CHWR CHILLED WATER RETURN

CHWS CHILLED WATER SUPPLY

CWR CONDENSER WATER RETURN

CWS CONDENSER WATER SUPPLY

D

(D) DEMOLISHED EQUIPMENT

DAT DISCHARGE AIR TEMPERATURE

DB DRY BULB

DDC DIRECT DIGITAL CONTROL

DN DOWN

DP DIFFERENTIAL PRESSURE

DX DIRECT EXPANSION

E

(E) EXISTING EQUIPMENT

EA EXHAUST AIR

EAD EXHAUST AIR DAMPER

EAT ENTERING AIR TEMPERATURE

EFF EFFICIENCY

ELEC ELECTRICAL

ESP EXTERNAL STATIC PRESSURE

EWT ENTERING WATER TEMPERATURE

F

FD FIRE DAMPER

FPM FEET PER MINUTE

FSD COMBINATION FIRE/SMOKE DAMPER

FT…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .