26.09.01 Repair and Replace Cathodic Protection Drawings.pdf
PDF 2 MB Posted
- Attached to
- VR25047 Cathodic Protection Repair
- Solicitation number
- 2140502
- Issued by
- Chautauqua County, New York
About this file
This file contains repair and replacement drawings for cathodic protection systems related to an RFQ issued by OPWDD's Broome DDSO for cathodic protection repair work on the heating water system at Valley Ridge CIT in Norwich, New York. The project involves repair or replacement of cathodic protection components, with a mandatory site visit scheduled for November 9, 2026 at 9:00 AM at 276 County Road 46, Norwich, NY. Quotes must be submitted using the Official Bid Form to brm.bids@opwdd.ny.gov no later than 5:00 PM on November 16, 2026. The contract term is 60 days from the date of award, with the location situated in Chenango County.
This is a Public Works Project requiring prevailing wage compliance. All vendors and sub-contractors must be registered with the New York State Department of Labor and provide a copy of their registration certificate with their quote. The Broome DDSO intends to award the contract to the most responsible and responsive vendor offering the lowest cost while meeting all scope of work requirements. The awarded vendor must provide certificates of Liability Insurance and Worker's Compensation Insurance, as well as completed Lobbying Law Forms and signed Appendix A documentation. The Broome DDSO reserves the right to reject all quotes and will make no concessions for vendor misunderstandings regarding project specifications or requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Cathodic Protection Scope.docx | DOCX document | |
| BRM RFQ Form 25-27.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4500 STATE ROUTE 434
APALACHIN, NY 13732
TEL: 607-223-4334
"UNAUTHORIZED ALTERATION OR ADDITION TO PLANS BEARING
A LICENSED ENGINEER'S OR ARCHITECTS SEAL, IS A VIOLATION
OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW"
PROJECT NO:
DATE:
SCALE:
DRAWN BY:
DESIGNED BY:
CHECKED BY:
OP-26002
09/01/2026
LAC
JWE
JWE
REVISIONS
MARK DATE DESCRIPTION
C
AT
H O
D
IC
P R
O
TE
C
TI
O N
NTS
VA
LL
EY
R
ID
G
E C
IT
D
C
B
A
1 2 3 4
1 2 3 4
D
C
B
A
T-100
ISSUED FOR
100% BID
TITLE SHEET
REPAIR AND REPLACE
CATHODIC PROTECTION
276 COUNTRY ROAD 46
NORWICH, NY 13815
PROJECT DATA DRAWING INDEX
AREA MAP LOCATION MAP
PROJECT ADDRESS:
276 COUNTRY ROAD 46 NORWICH, NY 13815
PROJECT SCOPE:
REPAIR AND REPLACEMENT OF SACRIFICAL MAGNESIUM CATHODIC PROTECTION ANODES
THAT HAVE SURPASSED THEIR LIFESPAN. EXISTING ANODES PROTECT PRE-FABRICATED
PERMA-PIPE SERVICE PIPES THAT RUN FROM THE MAIN FACILITY TO EACH HOUSING UNIT AND
BACK INTO THE MAIN FACILITY. THESE ANODES HAVE BEEN TESTED AND IDENTIFIED AS NO
LONGER CAPABLE OF PROVIDING SUFFICIENT PROTECTION AND NEED TO BE REPLACED.
SHEET NUMBER SHEET NAME
T-100 TITLE SHEET
E-001 CATHODIC PROTECTION GENERAL NOTES
E-101 ELECTRICAL NEW WORK
E-102 ELECTRICAL NEW WORK
E-501 ELECTRICAL DETAILS
1 07/23/2026 100% CD
09/01/2026 Issued for Bid2
Date: 09/01/2026
4500 STATE ROUTE 434
APALACHIN, NY 13732
TEL: 607-223-4334
"UNAUTHORIZED ALTERATION OR ADDITION TO PLANS BEARING
A LICENSED ENGINEER'S OR ARCHITECTS SEAL, IS A VIOLATION
OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW"
PROJECT NO:
DATE:
SCALE:
DRAWN BY:
DESIGNED BY:
CHECKED BY:
OP-26002
09/01/2026
LAC
JWE
JWE
REVISIONS
MARK DATE DESCRIPTION
C
AT
H O
D
IC
P R
O
TE
C
TI
O N
NTS
VA
LL
EY
R
ID
G
E C
IT
D
C
B
A
1 2 3 4
1 2 3 4
D
C
B
A
E-001
CATHODIC
PROTECTION
GENERAL
NOTES
CATHODIC PROTECTION GENERAL NOTES
1. SYSTEM DESIGN
1.1. THE CATHODIC PROTECTION SYSTEM WAS DESIGNED AS A SACRIFICIAL ANODE CATHODIC PROTECTION SYSTEM.
1.2. THIS PROJECT PRESERVES THE ORIGINAL DESIGN INTENT OF THE PIPE MANUFACTURER. THE PURPOSE OF THIS
PROJECT IS TO REPLACE THE ANODE SYSTEM WHICH IS BEYOND ITS USABLE LIFE.
1.3. THE SYSTEM IS DESIGNED AS A HEADER SYSTEM. THE ANODES ARE CONNECTED TO A COMMON ANODE HEADER WIRE.
THE HEADER WIRE IS CONNECTED TO THE CONDUIT/CONTAINMENT THROUGH THE TEST STATION(S).
1.4. THE DESIGN OF THE CATHODIC PROTECTION SYSTEM IS BASED ON A MINIMUM 20 YEAR ANODE LIFE AND AN ASSUMED SOIL RESISTIVITY OF 10,000 OHM-CM (MILDLY TO SLIGHTLY CORROSIVE). SOIL RESISTIVITY VALUES SHOULD BE
VERIFIED BY FIELD MEASUREMENTS OR SOIL SAMPLES.
2. ELECTRICAL ISOLATION
2.1. CATHODIC PROTECTION SYSTEM WARNING - AN ELECTRICAL SHORT TO ANOTHER METALLIC PIPING SYSTEM OR STRUCTURE IS THE PRIMARY CAUSE OF A CATHODIC PROTECTION SYSTEM NOT MEETING DESIGN REQUIREMENTS.
EXTREME CARE IS REQUIRED TO COMPLETELY ELECTRICALLY ISOLATE THE NEW CATHODICALLY PROTECTED SYSTEM
FROM OTHER PIPING SYSTEMS AND METALLIC STRUCTURES TO AVOID ELECTRICAL SHORTING.
2.2. USE EXTREME CARE TO PREVENT ANODES FROM CONTACTING ANY UNDERGROUND STRUCTURES.
3. INSTALLATION
3.1. INSTALLATION OF THE CATHODIC PROTECTION SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF THESE
DRAWINGS IS THE RESPONSIBILITY OF THE INSTALLER.
3.2. A CATHODIC PROTECTION TECHNICIAN CERTIFIED AT CP-2 OR HIGHER IS REQUIRED TO OVERSEE CATHODIC PROTECTION INSTALLATION AND PERFORM THE ACCEPTANCE TESTING OF THE INSTALLATION IN ORDER TO ENSURE
PROPER PERFORMANCE OF THE SYSTEM IS ACHIEVED.
3.3. ANODE INSTALLATION
3.3.1. ANODES MUST BE PROPERLY LOCATED AND CONNECTED TO THE CONDUIT/CONTAINMENT SYSTEM AT THE
LOCATIONS SHOWN ON THESE DRAWINGS.
3.3.2. ANODES MAY BE SHIPPED IN A CLOTH BAG OR CARDBOARD BOX CONFIGURATION. FOLLOW MANUFACTURER
INSTRUCTIONS DURING INSTALLATION.
3.3.2.1. IF USING CLOTH BAG ANODES, THE SHIPPING BAG MUST BE REMOVED PRIOR TO INSTALLATION. THE CLOTH
BAG CONTAINING THE ANODE AND BACKFILL MUST BE LEFT INTACT.
3.3.2.2. IF USING CARDBOARD BOX ANODES, THE ENTIRE ASSEMBLY, INCLUDING CARDBOARD BOX, MUST BE LEFT
INTACT.
3.3.3. DO NOT HANDLE ANODES BY THE LEAD WIRE. DO NOT DROP THE ANODE OR ATTEMPT TO LOWER THE ANODE BY
THE LEAD WIRE.
3.3.4. ANODES MUST BE INSTALLED:
- A MINIMUM OF 3' BELOW GRADE.
- WITH THE TOP OF THE ANODE AT OR BELOW THE CENTERLINE OF THE CONDUIT/CONTAINMENT.
- A MINIMUM OF 3' TO THE SIDE OF THE CONDUIT/CONTAINMENT.
- IN A VERTICAL OR HORIZONTAL POSITION.
- CLEAR OF ANY UNDERGROUND STRUCTURE.
3.3.5. ANODES SHALL BE SPACED AT EQUAL DISTANCES ALONG THE RUN OF CONDUIT/CONTAINMENT.
3.3.6. ANODES SHALL BE SOAKED WITH WATER PRIOR TO BACKFILLING. FIRMLY PACKED NATIVE SOIL SHALL BE
SCREENED AND USED FOR ANODE BACKFILLING. DO NOT USE SAND BACKFILL AROUND ANODES.
3.3.7. UNDERGROUND UTILITY LOCATIONS SHOWN ARE APPROXIMATE ONLY AND REQUIRE FIELD VERIFICATION BY THE CONTRACTOR. THE CONTRACTOR SHALL LOCATE UTILITIES WITHIN THE PROJECT CORRIDOR PRIOR TO COMMENCING CONSTRUCTION. DAMAGE TO UNDERGROUND UTILITIES FROM CONSTRUCTION ACTIVITIES SHALL BE
REPAIRED AT NO ADDITIONAL COST TO THE OWNER.
3.4. WIRING INSTALLATION
3.4.1. LEAVE SLACK IN ALL ANODE LEAD WIRES AND ANODE HEADER WIRES TO ALLOW FOR MOVEMENT AND SETTLING
OF THE CONDUIT/CONTAINMENT AND SOIL DURING BACKFILL AND OVER TIME.
3.4.2. AT TEST STATIONS, ALLOW 6" MINIMUM SLACK FOR ALL WIRES.
3.4.3. ALL UNDERGROUND WIRE SPLICES MUST BE WATER AND MOISTURE PROOF.
3.4.4. PHYSICAL DAMAGE TO WIRE INSULATION MUST BE AVOIDED. ALL WIRING MUST BE WATER AND MOISTURE PROOF.
IF DAMAGE DOES OCCUR TO WIRE INSULATION, REPAIR BY WRAPPING THE DAMAGED AREA WITH 2 LAYERS OF
RUBBER INSULATING TAPE THEN 1 LAYER OF PLASTIC ELECTRICAL TAPE.
3.5. TESTING
3.5.1. A NEGATIVE (CATHODIC) STRUCTURE-TO-ELECTROLYTE POTENTIAL OF AT LEAST -0.850 V OR MORE NEGATIVE MUST BE TESTED AND CONFIRMED AFTER INSTALLATION OF ALL CATHODIC PROTECTION ANODES.
3.5.2. A MINIMUM NEGATIVE (CATHODIC) POLARIZATION VOLTAGE SHIFT OF 100 mV MUST BE MEASURED BETWEEN THE
STRUCTURE SURFACE AND A STABLE REFERENCE ELECTRODE CONTACTING THE ELECTROLYTE.
3.5.3. REFER TO CORRTECH REPORT 17754-LTR-01-1 FOR TEST RESULTS REGARDING THE EXISTING SACRIFICAL ANODES
AND ISOLATION JOINTS ALONG THE PIPING NETWORK.
1 07/23/2026 100% CD
09/01/2026 Issued for Bid2
ISSUED FOR
100% BID
INV 1282.75
INV 1281.83
INV 1282.16
INV 1282.75
"B" HOUSE
"A" HOUSE
PROGRAM
BUILDING
TS #1
TS #2
TS #3
TS #4
4' 2'
2'
40'
5'-4" 4'7'-4"
4' 40'
40'
40'
40' 37'
40' 3'
11'
4'
5'
3'-9 3 16"
11'
3'-2 1 16"
2'-0"
20'-10" 3'-6"
15'
2' 2' 8'
20'-13 4"
2'-93 4"
17'
2'
2'
4' 19'-4"
21'-4"
A
A
A A
4500 STATE ROUTE 434
APALACHIN, NY 13732
TEL: 607-223-4334
"UNAUTHORIZED ALTERATION OR ADDITION TO PLANS BEARING
A LICENSED ENGINEER'S OR ARCHITECTS SEAL, IS A VIOLATION
OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW"
PROJECT NO:
DATE:
SCALE:
DRAWN BY:
DESIGNED BY:
CHECKED BY:
OP-26002
09/01/2026
LAC
JWE
JWE
REVISIONS
MARK DATE DESCRIPTION
C
AT
H O
D
IC
P R
O
TE
C
TI
O N
NTS
VA
LL
EY
R
ID
G
E C
IT
D
C
B
A
1 2 3 4
1 2 3 4
D
C
B
A
E-101
ELECTRICAL
NEW WORK
1 ELECTRICAL NEW WORK PLAN - PROGRAM BLDG TO BLDG B
SCALE: 1/8" = 1'
KEYED NOTES:
EXISTING #17 ANODES TO BE ABANDONED IN PLACE AND
DISCONNECTED FROM TEST STATIONS. NEW ANODES WILL BE
INSTALLED AND CONNECTED TO THE EXISTING TEST STATIONS.
GENERAL ELECTRICAL NEW WORK NOTES:
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BEGINNING WORK.
2. ALL AREAS OF THE BUILDING AFFECTED BY ELECTRICAL DEMOLITION WORK SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT FINAL FINISHES. THE REPAIR WORK SHALL BE DONE TO THE
CONTRACTING OFFICER'S SATISFACTION.
3. WORK REPLACED SHALL MATCH SIMILAR EXISTING WORK. STRUCTURAL MEMBERS OF
CONCRETE OR STRUCTURAL STEEL SHALL NOT BE CUT OR ALTERED, EXCEPT AS SHOWN,
WITHOUT AUTHORIZATION OF THE ENGINEER. WORK REMAINING IN PLACE DAMAGED OR
DEFACED DURING THIS CONTRACT SHALL BE RESTORED TO THE CONDITION AT TIME OF AWARD
OF CONTRACT. CUT, ALTER, REMOVE, OR TEMPORARILY REMOVE AND REPLACE EXISTING WORK
FOR INSTALLATION OF ELECTRICAL WORK.
CONDUIT PIPE SCHEDULE
SECTION SERVICE PIPE
INSULATION
THICKNESS
CONDUIT OUTSIDE
DIAMETER SERVICE
A 4" SCH. 40 HHWS&R2" 12-3/4"
B 3" SCH. 40 HHWS&R2" 10-3/4"
C 2-1/2" SCH. 40 HHWS&R2" 10-3/4"
CATHODIC PROTECTION SYMBOLS
#17 ANODES
TEST STATION
4", 150LB RATED ISOLATION FLANGE
KIT
3", 150LB RATED ISOLATION FLANGE
KIT
2-1/2", 150LB RATED ISOLATION
FLANGE KIT
COPPER/COPPER SULFATE
REFERENCE ELECTRODE
END SEAL ASSEMBLY
ANCHOR ASSEMBLY
FIELD JOINT ASSEMBLY
OVAL SUPPORTS
1 07/23/2026 100% CD
09/01/2026 Issued for Bid2
ISSUED FOR
INV 1280.75
INV 1281.16
"B" HOUSE
"C" HOUSE
TS #6
TS #5
22'
3'-10"
5'-10"
3'
3'
2'-83 4"
3'
3'-10"
4'-
3 4
A A
INV 1278.06
INV 1277.75
"D" HOUSE
"C" HOUSE
TS #10
TS #9
24'-10"
22'-10"
4'
4'
'-8
3 4"
3'-6 3 4 "
2'-10"
22'
22'
B B
INV 1279.16
INV 1278.75
"E" HOUSE
"D" HOUSE
TS #7
TS #8
24'-1 3 4 "
24'-10" 3'-33 4"
3'-6"
16'
15'
2' 2'
2' 2'7'
4' 20'-10"
19'-4"
C C
4500 STATE ROUTE 434
APALACHIN, NY 13732
TEL: 607-223-4334
"UNAUTHORIZED ALTERATION OR ADDITION TO PLANS BEARING
A LICENSED ENGINEER'S OR ARCHITECTS SEAL, IS A VIOLATION
OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW"
PROJECT NO:
DATE:
SCALE:
DRAWN BY:
DESIGNED BY:
CHECKED BY:
OP-26002
08/03/2026
LAC
JWE
JWE
REVISIONS
MARK DATE DESCRIPTION
C
AT
H O
D
IC
P R
O
TE
C
TI
O N
NTS
VA
LL
EY
R
ID
G
E C
IT
D
C
B
A
1 2 3 4
1 2 3 4
D
C
B
A
E-102
ELECTRICAL
NEW WORK
1 ELECTRICAL NEW WORK PLAN - BLDG B TO BLDG C
SCALE: 1/8" = 1'
2 ELECTRICAL NEW WORK PLAN - BLDG C TO BLDG D
SCALE: 1/8" = 1'
3 ELECTRICAL NEW WORK PLAN - BLDG D TO BLDG E
SCALE: 1/8" = 1'
1 1
KEYED NOTES:
EXISTING #17 ANODES TO BE ABANDONED IN PLACE AND
DISCONNECTED FROM TEST STATIONS. NEW ANODES WILL BE
INSTALLED AND CONNECTED TO THE EXISTING TEST STATIONS.
EXISTING ELECTRICALLY SHORTED ISOLATION FLANGE KIT TO BE
REMOVED AND REPLACED WITH NEW.
GENERAL ELECTRICAL NEW WORK NOTES:
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BEGINNING WORK.
2. ALL AREAS OF THE BUILDING AFFECTED BY ELECTRICAL DEMOLITION WORK SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT FINAL FINISHES. THE REPAIR WORK SHALL BE DONE TO THE
CONTRACTING OFFICER'S SATISFACTION.
3. WORK REPLACED SHALL MATCH SIMILAR EXISTING WORK. STRUCTURAL MEMBERS OF
CONCRETE OR STRUCTURAL STEEL SHALL NOT BE CUT OR ALTERED, EXCEPT AS SHOWN,
WITHOUT AUTHORIZATION OF THE ENGINEER. WORK REMAINING IN PLACE DAMAGED OR
DEFACED DURING THIS CONTRACT SHALL BE RESTORED TO THE CONDITION AT TIME OF AWARD
OF CONTRACT. CUT, ALTER, REMOVE, OR TEMPORARILY REMOVE AND REPLACE EXISTING WORK
FOR INSTALLATION OF ELECTRICAL WORK.
CONDUIT PIPE SCHEDULE
SECTION SERVICE PIPE
INSULATION
THICKNESS
CONDUIT OUTSIDE
DIAMETER SERVICE
A 4" SCH. 40 HHWS&R2" 12-3/4"
B 3" SCH. 40 HHWS&R2" 10-3/4"
C 2-1/2" SCH. 40 HHWS&R2" 10-3/4"
CATHODIC PROTECTION SYMBOLS
#17 ANODES
TEST STATION
4", 150LB RATED ISOLATION FLANGE
KIT
3", 150LB RATED ISOLATION FLANGE
KIT
2-1/2", 150LB RATED ISOLATION
FLANGE KIT
COPPER/COPPER SULFATE
REFERENCE ELECTRODE
END SEAL ASSEMBLY
ANCHOR ASSEMBLY
FIELD JOINT ASSEMBLY
OVAL SUPPORTS
1 07/23/2026 100% CD
09/01/2026 Issued for Bid2
ISSUED FOR
10'-10"
TYP
3'-0"
MIN.
GRADE EXISTING 3" x 12" x 12"
CONCRETE SLAB TO
REMAIN FLUSH TEST STATION WITH
REMOVABLE COVER
TOP OF ANODES MUST
BE AT OR BELOW
CENTERLINE OF PIPE .
#12 TEST LEAD
WIRE
THERMITE WELD
CABLE SPLICE
TO TEST
STATION
ANODE COLLECTOR CABLE
HIGH POTENTIAL
MAGNESIUM ANODE
#12 STRUCTURE
LEAD WIRE
3" MIN.
NOTE: ANODE IS INDICATED AS INSTALLED IN THE VERTICAL POSITION FOR
CLARITY. ANODE MAY BE INSTALLED IN THE VERTICAL OR HORIZONTAL POSITION.
3'
0" M
IN
CATHODICALLY PROTECTED
UNDERGROUND PIPE
ANODE BACKFILL (A MIXTURE OF HYDRATED
GYPSUM, POWDERED BENTONITE, AND SODIUM
SULFATE PREPACKAGED INSIDE OF THE ANODE)
COTTON SACK OR
CARDBOARD BOX
GALVANIZED STEEL
STRAP CORE
HEAT SHRINK PE TUBE
COVERED
THERMIT WELDING
PVC TAPE WRAPPING
1C-#12 THWN
2'-11
2"
6"
2'-6"
A
A
SECTION A-A
2"
3"
3"
SPECIFICATION OF MAGNESIUM ANODE
SIZE: 3" x 3" x 25.5"
WEIGHT: 17LB
WRAP CONNECTOR WITH TAPE.
THEN POSITION IN CENTER OF
PAD.
FIG. 1 FIG. 2
FOLD BOTTOM LEFT CORNER OF
PAD OVER CONNECTOR. STRETCH
PAD AROUND CABLE.
FIG. 3
FOLD OTHER CORNER OVER
CONNECTOR AS SHOWN. STRETCH
PAD AROUND CABLE.
FIG. 4
FOLD TOP OF PAD DOWN OVER
CONNECTOR.
FIG. 5
FOLD AROUND CONNECTOR AS
SHOWN. STRETCH AROUND CABLE.
FIG. 6
NOTES:
1. MAKE ELECTRICAL WIRE SPLICE CONNECTION AS REQUIRED.
2. VIGOROUSLY SAND HEADER & ANODE WIRE INSULATION
APPROXIMATELY 2 INCHES BACK FROM THE CONNECTION.
3. IF RE-ENTRY MAY BE REQUIRED, TAPE THE CONNECTION
FIRST WITH ONE LAYER OF VINYL TAPE.
4. ENFOLD THE CONNECTION USING THE SQUARE MASTIC
SPLICING PATCH, KNEADING THE MASTIC SEALANT SO THAT IT
COVERS THE ENTIRE SPLICE AND BONDS COMPLETELY TO
ITSELF.
5. COVER THE SPLICE PATCH MASTIC MATERIAL WITH ONE
LAYER OF RUBBER TAPE.
6. COVER RUBBER TAPE WITH TWO LAYERS OF VINYL TAPE.
UNDERGROUND SPICE IS COMPLETE.
STUDS
1/8" THICK STEEL WASHER
NOMEX ISOLATION SLEEVE
NUTISOLATION WASHER
NEMA GRADE 7
SERVICE PIPE FLANGES
FULL FACE PTFE ISOLATION
GASKET
NOTES:
1. USE ONLY HIGH TENSILE STUDS AND HEAVY
SERIES NUTS. STUDS MUST BE 1/2" MINIMUM
LONGER THAN STANDARD TO ACCOMMODATE
ISOLATION WASHERS
2. PROPERLY ALIGN FLANGE FACES TO AVOID
DAMAGE TO FLANGE ISOLATION KIT
MATERIALS.
3. ISOLATION FLANGES MUST BE INSTALLED
SUCH THAT THE FORCES CREATED BY THE
PIPE ON THE FLANGES CAUSE COMPRESSION
OF THE ISOLATION GASKET.
4500 STATE ROUTE 434
APALACHIN, NY 13732
TEL: 607-223-4334
"UNAUTHORIZED ALTERATION OR ADDITION TO PLANS BEARING
A LICENSED ENGINEER'S OR ARCHITECTS SEAL, IS A VIOLATION
OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW"
PROJECT NO:
DATE:
SCALE:
DRAWN BY:
DESIGNED BY:
CHECKED BY:
OP-26002
09/01/2026
LAC
JWE
JWE
REVISIONS
MARK DATE DESCRIPTION
C
AT
H O
D
IC
P R
O
TE
C
TI
O N
NTS
VA
LL
EY
R
ID
G
E C
IT
D
C
B
A
1 2 3 4
1 2 3 4
D
C
B
A
E-501
1 07/23/2026 100% CD
ELECTRICAL
DETAILS
1 ANODE TEST STATION DETAIL
SCALE: NTS
2 #17 ANODE DETAIL
SCALE: NTS
3 TYPE S SPLICE KIT INSTALLATION DETAIL (TYP.)
SCALE: NTS
4 CATHODIC PROTECTION FLANGE ISOLATION KIT
SCALE: NTS
09/01/2026 Issued for Bid2
ISSUED FOR
| Cathodic Protection Drawings-T-100 |
| Sheets and Views |
| T-100 |
| Cathodic Protection Drawings-E-001 |
| Sheets and Views |
| E-001 |
| Cathodic Protection Drawings-E-101 |
| Sheets and Views |
| E-101 |
| Cathodic Protection Drawings-E-102 |
| Sheets and Views |
| E-102 |
| Cathodic Protection Drawings-E-501 |
| Sheets and Views |
| E-501 |
File details come from the government source that posted it. Updated .