26-8683_Exhibit_M6_-_Instrumental_Plans.pdf
PDF 694 KB Posted
- Attached to
- SCRWTP Lime Softening Improvements - Blend Tank
- Solicitation number
- 26-8683
- Issued by
- Collier County, Florida
About this file
This file is an instrumentation legend and technical specification document prepared by ADS Engineering for Collier County, Florida's SCRWTP Lime Softening Improvements project (Bid No. 26-8683). The document provides comprehensive standardized symbols, abbreviations, and installation details for instrumentation and control systems to be incorporated into the blend tank and related water treatment facilities. The project includes specifications for multiple sensor types including pH analyzers, chlorine residual monitors, level transmitters, temperature sensors, and leak detection systems. The technical plans reference the blend tank piping and instrumentation diagram (P&ID), with specific equipment such as Switch-Tek leak detection sensors and controllers, SCADA/PLC integration, and detailed wiring diagrams for analog and discrete input/output signals. Installation details are provided for outdoor transmitters, analyzer systems, ultrasonic level elements, and stanchion-mounted instrumentation with mounting specifications and environmental protection requirements. The document indicates a non-mandatory pre-bid meeting scheduled for June 9, 2026 at 11:00 AM at the South County Regional Water Treatment Plant, with sealed bids due no later than July 1, 2026 at 3:00 PM.
The instrumentation specifications require contractors to reuse existing I/O signals in the current PLC cabinet while providing field investigation and necessary panel modifications to accommodate new signals, including additional I/O cards, terminals, surge suppressors, and wiring at no additional cost to the owner. Multiple leak detection systems are mandated for double-wall contained piping on injection lines, with specified manufacturers and model requirements including controllers with dual and triple switch inputs, relay outputs, and alarm accessories. The document establishes detailed requirements for signal conditioning, surge protection using Type 2, 3, and 4 surge suppressors, proper grounding protocols, and shielded pair cabling installation. Technical specifications address transducer installations, flow-through analyzer configurations, and insertion-type instrument mounting with rain hoods and sunshade curtains for outdoor applications. The plans are digitally signed and sealed by Aleksandar D. Stojanovic, with a project number of 204170 and file designation as 26-8683 Exhibit M6.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VFD VARIABLE FREQUENCY DRIVE
DRAIND
FREE CHLORINEFCL
HUMAN MACHINE INTERFACE
HAND-OFF-AUTOHOA
HMI
ZERO DIFFERENCEZR
POSITION ADJUST
ZK
YS
ON STATUS
UPSTREAM SETPOINTUSP
TOTAL CHLORINETCL
START-STOPSS
RUN COMMANDRK
REMOTE I/O UNITRIO
OPEN-STOP-CLOSE
OXIDATION REDUCTION POTENTIALORP
OOA
ON-OFFOO
ON-OFF-AUTO
OPEN COMMANDOK
OSC
OPERATOR INTERFACE UNITOIU
OPEN-CLOSE-REMOTEOCR
OPTICAL COMMUNICATION MODULE
OPEN & CLOSE COMMANDS
OPEN-CLOSE(D)OC
OCM
OCK
MANUAL TRANSFER SWITCH
MOTOR TEMPERATURE DETECTOR
MTS
MTD
MOTOR CONTROL CENTERMCC
LOCAL CONTROL PANELLCP
IN REMOTEIR
IN PLC REMOTEIP
FAIL CLOSEDFC
FIBER
FAIL ALARMFA
FB
CATIONIC POLYMERCPOL
CONTROLCNTL
CLOSE COMMANDCK
BACKWASHBW
BACK FLOW PREVENTERBFP
ADJUSTABLE SPEEDAS
ACKNOWLEDGEACK
= MIXER
LLL
EXAMPLES
FIBER OPTIC MEDIA CONVERTER
FIBER OPTIC PATCH PANEL
FOMC
FOPP
UPS
ISX
SSX
UNINTERRUPTABLE POWER SUPPLY
INTRINSIC SAFETY BARRIER TYPE X
SURGE SUPPRESSOR TYPE X
OTHER DEVICES
MXR
PMP
GTE
MODULATEM
INTERFACE TO OR FROM
PROCESS EXTERNAL TO
PROJECT
M x
M
CHLORINE (TYPICAL: USE STANDARD CHEMICAL ELEMENT
ABBREVIATION)
SIMILAR PROCESS OR
L L L L L
X X X X
UNIT NUMBER
LOOP NUMBER
CLARIFYING ABBREVIATIONS
FIRST LETTER(S)F
UU
BB
IT SUCCEEDING LETTER(S)
UP UNIT PROCESS NUMBER
LOCK-OUT-SWITCH
LOS
HS
UU
ON AND OFF EVENT LIGHTS (TWO LIGHTS TOTAL)
EQUALS
ON EVENT LIGHT
YL
ELECTRIC ACTUATOR WITH MULTI-VARIABLE,
MULTI-FUNCTION OPERATOR STATION, INCLUDING
LOCAL/OFF/REMOTE HANDSWITCH, OPEN/STOP/CLOSE
PUSHBUTTON AND OPEN CLOSED STATUS LIGHTS
OC
ZL
OSC
HS
LOR
HS
M
MOMENTARY CONTACT CONTROL SWITCH
OPEN-STOP-CLOSE
ELECTRIC ACTUATOR WITH INTEGRAL
POWER AFTER POWER FAILURE).
(CONTROLLED DEVICE WILL RESTART ON RETURN OF
ON-OFF HAND SWITCH. MAINTAINED CONTACT SWITCH
OSC
HS
SSHS
OOHS
OCZS
OCZL
OOYL
OPENED AND CLOSED POSITION LIGHTS
OPENED AND CLOSED POSITION SWITCHES
ON RETURN OF POWER AFTER POWER FAILURE).
SWITCHES (CONTROLLED DEVICE WILL NOT RESTART
STOP-START HAND SWITCH MOMENTARY CONTACT
MANUFACTURER
SUPPLIED CABLEMSC
PWR POWER
o o o
T
= TANK
Y X
= UNIT NUMBER
= LOOP NUMBER
I/PFY
PANEL, IN A FLOW LOOP)
TRANSDUCER (BACK OF
CURRENT TO PNEUMATIC
INTERFACE SYMBOLS
EQUIPMENT TAG NUMBERS
SELF CONTAINED VALVE &
ABBREVIATIONS & LETTER SYMBOLSLINE LEGENDINSTRUMENT IDENTIFICATION
TRANSDUCERS
EXAMPLE:
INSTRUMENT IDENTIFICATION LETTERS TABLEEXAMPLE SYMBOLS
DIGITAL SYSTEM INTERFACES
GENERAL INSTRUMENT
OR FUNCTIONAL SYMBOLS
ARV
= PUMP
W-D-X-Y
USER'S CHOICE
USER'S CHOICEUSER'S CHOICEUSER'S CHOICE
USER'S CHOICE
USER'S CHOICE
USER'S CHOICEUSER'S CHOICEUSER'S CHOICE
PLC FUNCTION
COMPUTER FUNCTION
WHEN USED, DEFINE THE MEANING HERE FOR THE PROJECT
TABLE BASED ON THE INSTRUMENTATION, SYSTEMS, AND AUTOMATION SOCIETY (ISA) STANDARD.
WHEN USED, EXPLANATION IS SHOWN ADJACENT TO INSTRUMENT SYMBOL. SEE ABBREVIATIONS AND LETTER SYMBOLS.
MULTIFUNCTIONMULTIFUNCTIONMULTIFUNCTIONMULTIVARIABLE
TORQUE
PRIMARY ELEMENT, SENSOR
SUCCEEDING-LETTERSFIRST-LETTER
Z
Y X
W
V U T S R
Q
P O N
M L
K J I
Z AXIS
Y AXIS
X AXIS
WEIGHT, FORCE
SPEED, FREQUENCY
RUN
QUANTITY
PRESSURE, VACUUM
ORIFICE, RESTRICTION
MOMENTARY
TIME, TIME SCHEDULE
CURRENT (ELECTRICAL)
BURNER, COMBUSTION
UNCLASSIFIED (+)UNCLASSIFIED (+) UNCLASSIFIED (+)UNCLASSIFIED (+)
ANALYSIS (+)
WELL
TRANSMIT
SWITCHSAFETY
RECORD OR PRINT
LOWLIGHT (PILOT)
CONTROL STATION
SCAN
INDICATE
HIGH
GATE
CONTROL
DIFFERENTIAL
ALARM
POSITION
TEMPERATURE
MOISTURE
LEVEL
POWER
HAND (MANUAL)
FLOW RATE
VOLTAGE
DENSITY (S.G)
H
G
F E D C B A
MODIFIEROUTPUT FUNCTIONMODIFIERLETTER
I
H R
PD
PF
P
F
E
D
A
CL etc.
STATUS
WHERE X=
MOMENTARY
S M
MAINTAINED
ALARM
H A
LLL-UU
BB
UPFIT
(B)
TOTAL OF 2 SIGNALS(A)
PARALLELING LINES
3(2)(2)
(B)(A)
MANUFACTURER SUPPLIED CABLEMSC
DATA LINK
ELECTRICAL SIGNAL
ALTERNATE FLOW STREAM)
DASHED LINE INDICATES
PROCESS (CLOSED CONDUIT,
FACILITY BOUNDARY
HYDRAULIC SYSTEM SIGNAL
CONNECTING LINES
FILLED SYSTEM SIGNAL
PNEUMATIC SIGNAL
PROCESS (OPEN CHANNEL)
DISCRETE INPUT
DISCRETE OUTPUT
ANALOG OUTPUT
ANALOG INPUT
INTRINSICALLY SAFE RELAYISR
PROGRAMMABLE LOGIC CONTROLLERPLC
GAIN OR ATTENUATE
BIAS
SET POINTSP
f(x)
SELECT LOWEST SIGNAL
SELECT HIGHEST SIGNAL
REPEAT OR BOOST
AVERAGE
SQUARE ROOT
RAISE TO THE Nth POWER
CHARACTERIZED
DIVIDE
X MULTIPLY
DIFFERENCE
TURBIDITY
TOTAL OXYGEN DEMAND
TOTAL ORGANIC CARBON
TOTAL CHLORINE RESIDUAL
VIBRATIONVIB
TURB
TOD
2TCL
TOC n
SUM
1:1
AVG
X
HYDROGEN ION CONCENTRATIONpH
MOTOR CONTROL CENTER NO. X
LOCAL-REMOTE
MCC-X
LR
HAND-OFF-REMOTEHOR
2FCL FREE CHLORINE RESIDUAL
DISTRIBUTED CONTROL UNITDCU
CONTROL PANEL NO. XCPX
ALTERNATING CURRENTAC
MIDDLE,
INTERMEDIATE
INTEGRATE,
TOTALIZE
RATIO
(FRACTION)
POINT (TEST)
CONNECTION
DRIVE, ACTUATOR,
UNCLASSIFIED FINAL
CONTROL ELEMENT
RELAY, COMPUTE,
CONVERT
EVENT, STATE OR
PRESENCE
VALVE, DAMPER,
LOUVER
VIBRATION, MECHANICAL
ANALYSIS
TIME RATE
OF CHANGE
GLASS, GAUGE
VIEWING DEVICE
READOUT OR
PASSIVE FUNCTION
PROCESS OR
INITIATING VARIABLE
NON-CONNECTING
LINES
3 TYPICAL SETS OF
2 SIGNALS EACH.
TOTAL OF 6 SIGNALS.
MCC MOUNTED
PANEL MOUNTED
(OPERATOR ACCESSIBLE)
REAR-OF-PANEL MOUNTED
(OPERATOR INACCESSIBLE)
FIELD MOUNTED
SHARED DISPLAY,
SHARED CONTROL
D:
W
M
E
AVRV
= AIR AND VACUUM RELEASE VALVE
= UNIT PROCESS NUMBER
= MECHANICAL EQUIPMENT
= EJECTOR
= AIR RELEASE VALVE
= GATE
EQUIPMENT
PACKAGE SYSTEM
HYDRAULIC RESISTANCE
ANALOG
DIGITAL
PULSE DURATION
PULSE FREQUENCY
PNEUMATIC
CURRENT
FREQUENCY
VOLTAGE
x =
OTHER SECTION OF THIS CONTRACT
DENOTES EQUIPMENT SPECIFIED UNDER
PROVIDED BY OTHERS UNDER A SEPARATE CONTRACT
DENOTES EXISTING EQUIPMENT OR EQUIPMENT
ANALOG OUTPUTAO
ANALOG INPUTAI
CONDUCTIVITYCOND
CONSTANT SPEEDCS
CHLORINE RESIDUALCR
CENTRAL TELEMETRY UNITCTU
DIGITAL INPUTDI
DIGITAL OUTPUTDO
DIRECT CURRENTDC
ELAPSED TIME METERETM
MOTOR CONTROLLERMC
MOTOR OPERATED VALVEMOV
NORMALLY OPEN
NORMALLY CLOSED
NO
NC
REMOTE TERMINAL UNITRTU
SPECIFICATIONS. FOR MULTIPLE PACKAGES ON SAME
DRAWING, USE * , * 2, *3, ETC.
COMPONENTS SHOWN WITH A DIAMOND ( ) ARE PART
OF DIVISION 40 INSTRUMENTATION AND CONTROLS
COMPONENTS AND PANELS SHOWN WITH A ASTERISK ( ** )
THIS INFORMATION MAY BE USED ON THIS PROJECT.
THIS IS A STANDARD LEGEND. THEREFORE, NOT ALL OF3.
ARE PART OF A PACKAGE SYSTEM; SEE EQUIPMENT
2.
1.
GENERAL NOTES
LINE CONTENTS IN OR
OUT OF DRAWING
DWG NO.
DIGITAL INPUT (DI) DIGITAL OUTPUT (DO)
ANALOG INPUT (AI) ANALOG OUTPUT (AO)
TC = THERMOCOUPLE
X
RTD = RTD INPUT
INPUT
I/O SIGNALS
DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
204170
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
COLLIER COUNTY
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
00GN01
4701 N FEDERAL HWY, STE 390
POMPANO BEACH, FL 33064
PHONE (561) 210-5715
ADS
SIDZ
MDG
SCRWTP LIME SOFTENING IMPROVEMENTS
301 NORTH CATTLEMEN ROAD, SUITE 302
SARASOTA, FL. 343232
PHONE: (941) 371-9832 FAX: (941) 371-9873
CA 00008571
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME: 00GN01 - INSTRUMENTATION LEGEND - SHEET NO.1.DWG
AD
S
204170-100000
39APRIL 2026
BID DOCUMENTS
THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BY
ALEKSANDAR D.
STOJANOVIC ON THE
DATE ADJACENT TO
THE SEAL.
THE SIGNATURE MUST
BE VERIFIED ON ANY
ELECTRONIC COPIES.
INSTRUMENTATION
ABBREVIATIONS AND SYMBOLS - 1
projid=0003&linktab=EQP_LNK&linkid=0000000008& projid=0003&linktab=EQP_LNK&linkid=0000000009& projid=0003&linktab=EQP_LNK&linkid=0000000010& projid=0003&linktab=EQP_LNK&linkid=0000000010& projid=0003&linktab=EQP_LNK&linkid=0000000010& projid=0003&linktab=EQP_LNK&linkid=0000000011& projid=0003&linktab=EQP_LNK&linkid=0000000011& projid=0003&linktab=EQP_LNK&linkid=0000000011&
V
T
OR
:EH
FFLCPLLLX
PANEL CONTINUED
ON SAME OR OTHER
DRAWINGFILTER/
REGULATOR/
GAUGE SET
XX: FO =FAIL OPEN
FC =FAIL CLOSED
FLP=FAIL TO LAST POSITION
RECIPROCATING OR
METERING PUMP
(POSITIVE DISPLACEMENT)
PROGRESSIVE
CAVITY PUMP
COMPRESSOR
(CENTRIFUGAL)
COMPRESSOR
(PISTON)
S
PRESSURE RELIEF
AIR AND/OR VACUUM RELEASE
REGULATED SIDE
PRESSURE CONTROL
GATE
KNIFE GATE
BUTTERFLY
GLOBE
V-PORT BALL VALVE
PLUG
ECCENTRIC PLUG
DIAPHRAGM
PINCH
NEEDLE
BALL
SWING CHECK
BALL CHECK SAMPLE
MUD
SLUICE
BUTTERFLY FLAP
FABRICATED SLIDE
SEAT PORT
XX
XX
XX
XX
XX
XX
XX
XX
DIAPHRAGM PUMP
PISTON PUMP
EJECTOR
NOTE: XX:
XX
PARSHALL FLUME
WEIR
PITOT-STATIC
ROTAMETER
LEVEL (ULTRASONIC)
NOTE:
VORTEX METER
DENSITY METER
A
DIAPHRAGM SEAL
BLIND FLANGE
AIR GAP
VENT TO ATMOSPHERE
AERATOR
PLUG
RECEPTACLE
ANNULAR DIAPHRAGM SEAL
PIG INSERT POINT
PIG CATCH POINT
MIXER
ELECTRIC MOTOR
D
TV CAMERA TV MONITOR
A
A
B C
120 VOLT, 60 HZ POWER
480V
SD
XX
OR
PURGE SETX
FLUSHING CONNECTION
SEAL WATER SET
AIR SET
IN PSIG.
HOSE ADAPTOR
W = WATER
A = AIR
X
SEE
SIGHT GLASS
I
I B C
XX= SUPPLY PRESSURE
MULTI-PORT VALVES
(GATE VALVE SHOWN. FOR OTHER
VALVE TYPES, APPROPRIATE
VALVE SYMBOL SHOWN. )
SEAT PORTS ARE IMPLIED BY
INDICATED FLOW PATTERN.
ELECTROMAGNETIC
FLOWMETER
ULTRASONIC
FLOWMETER
120V
SELF CONTAINED
AIR SUPPLY
COMPOSITE SAMPLER
(DIPPER TYPE)
SS
TV
AND
OR
COMPOSITE SAMPLER
(SUCTION TYPE)
LOGIC ELEMENT:
IF A AND NOT B THEN C
LOGIC ELEMENT:
IF A OR B THEN C
INTERLOCK. SEE
CONTROL DIAGRAMS
S
F
ADJUSTABLE SPEED
CONSTANT SPEED (SINGLE SPEED)
CONSTANT SPEED (TWO SPEED)
AS
CS-2
CENTRIFUGAL PUMP
(DRY PIT)
CENTRIFUGAL WET PIT
PUMP OR TURBINE PUMP
GEAR PUMP OR BLOWER
(POSITIVE DISPLACEMENT)
K
V
XX
ELECTROHYDRAULIC
ELECTRIC
HYDRAULICXX
MANUAL
XX
TELESCOPE
FI
DE
GENERIC
XX
RUPTURE DISK (PRESSURE)
RUPTURE DISK (VACUUM)
BLOWER OR FAN
(CENTRIFUGAL)
XX
TV
WITH POSITIONER
FLEXIBLE CONNECTOR
PULSATION DAMPENER
PANEL OUTLINE
PANEL NAME
STOP LOG
BACKFLOW PREVENTER
ROTARY
ANGLE GATE
PRESSURE REGULATING (CLAY-TYPE)
PROPELLER OR
TURBINE METER
THERMAL FLOWMETER
DRIP TRAP
AIR FILTER
FLAME TRAP
STRAINER
HORN
SCREW
SKIMMING MECHANISM
SCREW CONVEYOR
PIPE CAP
CALIBRATION COLUMN
VALVE SYMBOLS
GATE SYMBOLS
ACTUATOR SYMBOLS
PRIMARY ELEMENT SYMBOLS
MISCELLANEOUS SYMBOLS PUMP AND COMPRESSOR SYMBOLS
XX
SUBMERSIBLE
SUMP PUMP
VACUUM PUMP
ROTARY PUMP
SCREW PUMP
SHEAR
ORIFICE PLATE
480 VOLT, 3-PHASE, 60 HZ POWER
NO = NORMALLY OPEN
NC = NORMALLY CLOSED
O/C=OPEN/CLOSE
MOD=MODULATING
ON LOSS OF PRIMARY POWER (PNEUMATIC, ELECTRICAL OR HYDRAULIC)
4-WAY SOLENOID VALVES
CI CHLORINE INJECTOR
PNEUMATIC
XX
VERTICAL PUMP
FLOW STREAM IDENTIFICATION
AH AMMONIUM SULFATE
ALP AIR, LOW PRESSURE
BWW BACKWASH WASTE
CCR CLEANING CONCENTRATE RETURN
CF CLEANING FEED
CFR CLEANING FEED RETURN
CFI CARTRIDGE FILTER INFLUENT
CF/W SPENT CLEANING SOLUTION
CPR CLEANING PERMEATE RETURN
D DRAIN, SANITARY
DMP DEGASIFIED MEMBRANE PERMEATE
DR DRAIN, PROCESS
FS FIRE SPRINKLER
FW FINISHED WATER
HW TEMPERED POTABLE WATER
MC MEMBRANE CONCENTRATE
MF MEMBRANE FEED
MF/B MEMBRANE FEED BYPASS
MF/W MEMBRANE FEED WASTE
MP MEMBRANE PERMEATE
NA SODIUM HYDROXIDE
OF OVERFLOW
PMS PERMEATE MAKEUP SUPPLY
PP POLYPHOSPHATE
RWB RAW WATER - BISCAYNE
SA SAMPLE
SH SODIUM HYPOCHLORITE
SI SCALE INHIBITOR
SPD SUMP PUMP DISCHARGE
SSI SAND STRAINER INFLUENT
SU SULFURIC ACID
V VENT
W1 POTABLE WATER
W2 BACKFLOW PREVENTED POTABLE WATER
P z
XX WITH SOLENOID
PNEUMATIC P s
XX
E
ELECTRIC
XX
E z
WITH POSITIONER
H
XX VOLUME BOOSTER
PNEUMATIC WITHP B
HYDRAULICXXH
SOLENOIDS
ELECTRIC MOTOR
M
M
SINGLE SPEED
ADJUSTABLE SPEED
EXPANSION COUPLING
CS-1
CORIOLIS
FLOWMETER
SIMPLEX BASKET
FLOW SWITCH
ENERGY
RECOVERY
DEVICE
M
CARTRIDGE FILTER
STATIC MIXER
FLOW TUBE
(VENTURI) AIR VENT
FLAP GATE
HEATER INLINE
V
HE
HEAT ELEMENT
QUICK CONNECT
COUPLING
EYEWASH SHOWER
CHEMICAL INJECTION
ASSEMBLY
BLADDER TANK
LEVEL (RADAR)
LEVEL SWITCH (FLOAT)
EXHAUST FAN
ISOLATION DAMPENER
UNION
DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
204170
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
COLLIER COUNTY
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
00GN02
4701 N FEDERAL HWY, STE 390
POMPANO BEACH, FL 33064
PHONE (561) 210-5715
ADS
SIDZ
MDG
SCRWTP LIME SOFTENING IMPROVEMENTS
301 NORTH CATTLEMEN ROAD, SUITE 302
SARASOTA, FL. 343232
PHONE: (941) 371-9832 FAX: (941) 371-9873
CA 00008571
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME: 00GN02 - INSTRUMENTATION LEGEND - SHEET NO.2.DWG
AD
S
204170-100000
39APRIL 2026
BID DOCUMENTS
THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BY
ALEKSANDAR D.
STOJANOVIC ON THE
DATE ADJACENT TO
THE SEAL.
THE SIGNATURE MUST
BE VERIFIED ON ANY
ELECTRONIC COPIES.
INSTRUMENTATION
ABBREVIATIONS AND SYMBOLS - 2
projid=0351&linktab=INST_LNK&linkid=0000001558& projid=0351&linktab=INST_LNK&linkid=0000001558& projid=0351&linktab=INST_LNK&linkid=0000001558&
SCADA
PLC 2
LE
LIT
AE
AIT
AE
AIT
REVERSE OSMOSIS
PERMEATE
FILTER EFFLUENT
SODIUM HYDROXIDE
CORROSION INHIBITOR
FROM TRANSFER
PUMPS
TO TRANSFER PUMPS
AIR
pH
AIR
TO
TA
L C
H
LO
R
IN
E
LIR
LE
VE
L
BLEND TANK
CHLORINE
42" ROP (DIP)
36" LS (DIP)
1-1/2" CRI (CPVC)
CL2 TOT
CL2 TOT
pH pH
AE
410A
AIT
410A
AE
411A
AIT
411A
TIT
410A
TIR
410A
TE
M
PE
R
AT
U
R E
AIR
410A pH
AIR
411A
FR
EE
C H
LO
R
IN
E
CL2 FREE
CL2 FREE
pH pH 1 CONTRACTOR SHALL REUSE EXISTING I/OS IN THE
EXISTING PLC CABINET. CONTRACTOR SHALL FIELD
INVESTIGATE AND PROVIDE ANY NECESSARY
PANEL MODIFICATION TO ACCEPT NEW SIGNALS,
INCLUDING PROVIDING ADDITIONAL I/O CARDS,
TERMINALS, SURGE SUPPRESSORS, WIRING, ETC.
FOR COMPLETE WORKING SYSTEM IN PLACE
WITHOUT ADDITIONAL COST TO OWNER.
CONTRACTOR SHALL PROVIDE AND INSTALL LEAK
DETECTION SENSOR ON DOUBLE WALL CONTAINED
PIPING PER INSTALLATION DETAIL MANUFACTURED
BY SWITCH-TEK™ MODEL LO10 OPTIC LIQUID LEAK
DETECTION SWITCH FOR EACH INJECTION LINE AS
SHOWN ON P&ID.
CONTRACTOR SHALL PROVIDE CONTROLLER
SWITCH-TEK™ LC41-1001 WITH DUAL SWITCH
INPUT, SINGLE RELAY OUTPUT, 120VAC INSTALLED
IN NEMA 4X BOX SWITCH-TEK™ LM92-1202 WITH
STROBE AND HORN ACCESSORY SWITCH-TEK™
LC09-2014 AND ALARM RESET BUTTON LC09-0000.
CONTRACTOR SHALL PROVIDE CONTROLLER
SWITCH-TEK™ LC42-1001 WITH THREE SWITCH
INPUTS, TWO RELAY OUTPUTS, 120VAC INSTALLED
IN NEMA 4X BOX SWITCH-TEK™ LM92-1202 WITH
STROBE AND HORN ACCESSORY SWITCH-TEK™
LC09-2014 AND ALARM RESET BUTTON LC09-0000.
KEYED NOTES:
2 1/2" SHC (CPVC)
42" BFW (DIP)
2-1/2'' SHC (CPVC)
1/2" CS (CPVC)
BLEND TANK
SAMPLE PUMP
LSH
410A
LAH
410A
LE
AK
LSH
410B
LAH
410B
LE
AK
LD
CS
LD
CRI
LD
SHC
AMMONIA
1" AMS (CPVC)
LD
AMS
LEAK
DETECTOR
(TYP)
3 4
LEAK
DETECTION
ALARM
BOX (TYP)
LEAK
DETECTION
ALARM
BOX (TYP)
CHLORINE
WASTE TO DRAIN
LD
SHC
LEAK
DETECTOR
(TYP)
DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
204170
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
COLLIER COUNTY
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
00N01
4701 N FEDERAL HWY, STE 390
POMPANO BEACH, FL 33064
PHONE (561) 210-5715
ADS
SIDZ
MDG
SCRWTP LIME SOFTENING IMPROVEMENTS
301 NORTH CATTLEMEN ROAD, SUITE 302
SARASOTA, FL. 343232
PHONE: (941) 371-9832 FAX: (941) 371-9873
CA 00008571
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME: 00N01 - BLEND TANK.DWG
AD
S
204170-100000
39APRIL 2026
BID DOCUMENTS
THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BY
ALEKSANDAR D.
STOJANOVIC ON THE
DATE ADJACENT TO
THE SEAL.
THE SIGNATURE MUST
BE VERIFIED ON ANY
ELECTRONIC COPIES.
INSTRUMENTATION
BLEND TANK P&ID
projid=0351&linktab=INST_LNK&linkid=00000028P30& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001202& projid=0351&linktab=INST_LNK&linkid=00000028P30& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001202& projid=0351&linktab=INST_LNK&linkid=00000028P30& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001202& projid=0351&linktab=INST_LNK&linkid=00000028P30& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001202& projid=0351&linktab=INST_LNK&linkid=00000028P30& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001202& projid=0351&linktab=INST_LNK&linkid=00000028P30& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001202& projid=0351&linktab=INST_LNK&linkid=00000028P30& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=INST_LNK&linkid=00000028P30& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001201& projid=0351&linktab=EQP_LNK&linkid=0000001201&
SCALE: NTS
L
G
L
N
G
L
N
G
TWISTED, SHIELDED PAIR;
TAPE BACK SHIELD
AT TRANSMITTER END;
DO NOT GROUND
N 120VAC
POWER
PANELFIELD
GND
PLC, RTU
OR DCU
ANALOG
INPUTTO GROUND
BUS; DO NOT
DAISY CHAIN
24VDC
POWER
GND
TRANSMITTER
1.
2.
TWISTED, SHIELDED PAIR;
TAPE BACK SHIELD
AT TRANSMITTER END;
DO NOT GROUND
PANELFIELD
PLC, RTU
OR DCU
ANALOG
INPUT
GND
TO GROUND
BUS; DO NOT
DAISY CHAIN
TO PANEL SHIELD BUS,
DO NOT DAISY CHAIN
TO PANEL SHIELD BUS,
DO NOT DAISY CHAIN
TYPE 2 SURGE SUPPRESSOR.
NOTES:
TYPE 2 SURGE SUPPRESSOR.
NOTES:
1.
2.
TYPE 4 SURGE SUPPRESSOR. INSTALL USING DETAIL
TYPE 3 SURGE SUPPRESSOR. INSTALL USING DETAIL
2-WIRE TRANSMITTER
4-WIRE TRANSMITTER
TYPICAL OUTDOOR TRANSMITTERS
TRANSIENT SURGE
PROTECTOR
(NOTE 1)
PROTECTED SIDE
TRANSIENT SURGE
PROTECTOR
(NOTE 2)
PROTECTED SIDE
TRANSMITTER
PROTECTED
SIDE
#10
TRANSIENT SURGE
PROTECTOR
(NOTE 1)
TRANSIENT SURGE
PROTECTOR
(NOTE 2)
TWISTED
PAIR
TWISTED
PAIR
PROTECTED
SIDE
TO LOAD
120VAC
5A MAX
INTERPOSING
RELAY
PANELFIELD
LOCAL OVERRIDE
CONTROL
PLC, RTU
OR DCU
DISCRETE
OUTPUT
PANELFIELD
PLC, RTU
OR DCU
DISCRETE
INPUT
POWER
TWISTED, SHIELDED PAIR;
TAPE BACK SHIELD
AT TRANSMITTER END;
DO NOT GROUND
PANELFIELD
GND GND
TO GROUND
BUS; DO NOT
DAISY CHAIN
PLC, RTU
OR DCU
ANALOG
OUTPUT
TYPICAL DISCRETE INPUT TYPICAL DISCRETE OUTPUT
TO PANEL SHIELD
BUS; DO NOT DAISY
CHAIN
TYPICAL OUTDOOR ANALOG OUTPUT
1. EDCO MODEL SS64-036-2; OR EQUAL.
2. EDCO MODEL PC-642-036; OR EQUAL.
NOTES:
TRANSIENT SURGE
PROTECTOR
(NOTE 1)
LOAD
TRANSIENT SURGE
PROTECTOR
(NOTE 2)
FIELD
CONTACT
TWISTED PAIR
SCALE: NTS
FUSED
TERMINAL
BLOCK
FUSED
TERMINAL
BLOCK
FUSED
TERMINAL
BLOCK
FUSED
TERMINAL
BLOCK
X
X
O O R
GND
TRANSIENT SURGE
PROTECTOR
120 VAC
PROBE
4-20 MA OUTPUT
PROBE CABLE TO BE SUPPLIED
WITH INSTRUMENT TO LENGTH
CONDUIT CONNECTION TO
PROBE HOLDER.
ANALYZER-TRANSMITTER
(PANEL, SURFACE OR PIPE
MOUNT)
TYPICAL FLOW THRU ANALYZER INSTALLATION
(pH/COND/ORP/CL2)
TWIST LOCK
TYPE HOLDER
NOTES:
1) REFERENCE INSTRUMENT RACK DETAILS FOR EXACT PIPING
INSTALLATION DETAIL
SCALE: NTS
FLOW
SAMPLE
pH INSERTION TYPE INSTRUMENT INSTALLATION
BALL
VALVE
pH
PROBE
SIGNAL
CONDUIT
POWER
CONDUIT
SENSOR
CABLE
ANALYZER /
TRANSMITTER
NOTES:
1. SAMPLE MUST BE TAKEN FROM MIDSTREAM FLOW.
2. INSTALL IN PIPING TO ENSURE SUBMERGENCE UNDER
NON-PRESSURIZED CONDITIONS
SCALE: NTS SCALE: NTS
NOTES:
2' -6
4' -6
ROUND OFF ALL EXPOSED EDGES AND CORNERS.
G
1" NONSHRINK
GROUT
4"x2" AL REDUCER
3/16
3/16
3/16
1.
2.
RAIN HOOD REQUIRED
FOR OUTDOOR APPLICATION
WITH SUNSHADE CURTAIN.
MOUNTING HOLES TO SUIT INSTRUMENT
SECURE INSTRUMENT TO STANCHION
W/SST BOLTS, NUTS & WASHERS
TO
S
U
IT
IN
ST
R U
M
EN
T
PAINT ALUMINUM IN CONTACT WITH CONCRETE ACCORDING TO
SPECIFICATIONS FOR PAINTING.
L 2-1/2"x2"x1/4"
AL LENGTH TO
SUIT INSTRUMENT
INSTRUMENT
L 2-1/2"x2"x1/4" AL
LENGTH TO SUIT
INSTRUMENT
PL 1/2"x12"x12", AL
SECURE TO SLAB WITH
(4) 1/2" SST CONCRETE
ANCHORS
2" SCHED 40 AL PIPE
4" SCHED 40 AL PIPE
STANCHION SUPPORT FOR CASE MOUNTED INSTRUMENTS CHLORINE ANALYZER SYSTEM
SCALE: NTS
TRANSMITTER
SENSOR
1. SAMPLE INLET FITTING
2. EXTERNAL AIR BREAK
3. SAMPLE DRAIN TUBING
4. GRAB SAMPLE ASSEMBLY
5. Y-STRAINER ASSEMBLY
6. SHUT-OFF VALVE AT THE Y-STRAINER
7. SENSOR / CONTROLLER / TRANSMITTER
8. SAMPLE BYPASS TUBING
9. PRESSURE REGULATOR
10. COORDINATE WITH PLANT STAFF ON
LOCATION OF EXISTING ANALYZER
DRAIN LINE. SEE MECHANICAL SHEET
M02
SAMPLE INLET
3 4
NOTES:
INSTALLATION WITH PRESSURE REGULATOR
SCALE: NTS
SCALE: NTS
8" DUCTILE IRON FLOOR
PIPE WITH INTEGRALLY
CAST SEEP RING,
CENTERED IN SLAB
NOTES:
CONDUIT ELBOW
1.
2. COAT FLOOR PIPE WITH SPECIFIED PAINT SYSTEM PRIOR TO
CONCRETE PLACEMENT.
CABLE CONNECTOR
FITTING
* NEOPRENE GASKET
* NYLON BOLTS & NUTS
ROOF SLAB
1'-4" MAX
CONDUIT TEE
1" PVC COUPLING *
ULTRASONIC LEVEL ELEMENT
INSTALLATION - CONCRETE ROOF
FLANGE MOUNTED
ULTRASONIC
TRANSDUCER *
SENSOR CABLES IN
CONDUIT TO
TRANSMITTER *
COMPONENTS DESIGNATED BY * ARE SUPPLIED BY INSTRUMENT
MANUFACTURER.
SCALE: NTS
AMBIENT
TEMPERATURE
SENSOR *
TEE AND BUSHINGS
AS REQUIRED
ANALYZER
BYPASS LINE
DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
204170
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
COLLIER COUNTY
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
00TN01
4701 N FEDERAL HWY, STE 390
POMPANO BEACH, FL 33064
PHONE (561) 210-5715
ADS
SIDZ
MDG
SCRWTP LIME SOFTENING IMPROVEMENTS
301 NORTH CATTLEMEN ROAD, SUITE 302
SARASOTA, FL. 343232
PHONE: (941) 371-9832 FAX: (941) 371-9873
CA 00008571
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME: 00TN01 - INSTRUMENT DETAILS.DWG
AD
S
204170-100000
39APRIL 2026
BID DOCUMENTS
THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BY
ALEKSANDAR D.
STOJANOVIC ON THE
DATE ADJACENT TO
THE SEAL.
THE SIGNATURE MUST
BE VERIFIED ON ANY
ELECTRONIC COPIES.
INSTRUMENTATION
TYPICAL DETAILS
| ADS Engineering | |
| 2026-05-13T18:34:52-0400 | |
| Aleksandar Stojanovic |
File details come from the government source that posted it. Updated .