This is a construction document set consisting of architectural, mechanical, and electrical plans for the renovation of 206 North Union Street in Danville, Virginia, prepared for North Union Properties, LLC. The project involves renovation work to a two-story, 10,755 square-foot building classified as Group B occupancy (Business) with Type-IIIB construction. The scope includes demolition of existing mezzanines and internal partitions, creation of two retail tenant spaces (Tenant A and Tenant B) and a backroom, installation of new mechanical systems consisting of two 3-ton air handlers with heat pump units, new electrical distribution and lighting systems, plumbing fixture upgrades, and life safety improvements including fire-rated wall assemblies and egress modifications. The project requires compliance with Virginia Construction Code (2021), Virginia Energy Conservation Code (2021), and Virginia Statewide Fire Prevention Code (2021). The pre-bid meeting is scheduled for Tuesday, September 29, 2026, at 10:00 AM; the deadline for submitting questions is Wednesday, October 7, 2026, at 5:00 PM; and bids open Thursday, October 15, 2026, at 4:30 PM.

The construction documents specify multiple code compliance requirements including fire-resistance ratings for wall assemblies (minimum 1-hour fire-rated construction utilizing UL Design No. 301), occupant load calculations (24 total occupants across retail and support spaces), and egress capacity standards requiring minimum widths of 32 inches for exits. Mechanical systems are designed for heating loads of 15,800-16,246 BTU/h and cooling loads of 17,807 BTU/h (sensible) with additional latent cooling capacity of 7,832 BTU/h per zone. Electrical work includes installation of new panel boards (Panels A1, A2, and J), LED lighting fixtures with emergency battery backup, GFCI-protected receptacles, and data/communications infrastructure with CAT 6 cabling. The renovation maintains existing EPDM roofing and structural elements while upgrading all mechanical, electrical, and plumbing systems to current code standards. General contractor responsibilities include coordination of all trades, site safety, asbestos floor tile removal, utility connections, and restoration of adjacent areas affected by construction operations.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP

REFERENCE CODES

VIRGINIA CONSTRUCTION CODE (VCC), 2021 ED.

VIRGINIA ENERGY CONSERVATION CODE, 2021 ED.

VIRGINIA STATEWIDE FIRE PREVENTION CODE (SFPC), 2021 ED.

ALL APPLICABLE NFPA FIRE CODES INCLUDING BUT NOT LIMITED TO :

NFPA, 2021 ED.

AMERICAN DISABILITY ACT - ADA ACCESSIBILITY GUIDELINES, 2010 ED.

BUILDING OCCUPANCY AND CLASSIFICATIONS:

THE OCCUPANCY IS CLASSIFIED AS "B" - BUSINESS

BUILDING OCCUPANCY CATEGORY

THIS BUILDING IS TYPE-II OCCUPANCY PER VCC TABLE 1604.5

CONSTRUCTION TYPE

THIS BUILDING IS TYPE-IIIB CONSTRUCTION PER VCC (TABLE 601)

AND TYPE-III (2,0,0) PER NFPA 220.

GENERAL BUILDING LIMITATIONS

ACTUAL BUILDING AREA

BUILDING GROSS AREA: 10,755 SF

ALLOWABLE AREA / HEIGHT FOR B OCCUPANCY

PER TABLE 504.3, THE ALLOWABLE BUILDING HEIGHT OF A NON-

SPRINKLED GROUP B, TYPE-IIIB, BUILDING IS LIMITED TO 55 FEET.

PER TABLE 504.4, THE ALLOWABLE NUMBER OF STORIES OF A NON-

SPRINKLED GROUP B, TYPE-IIIB, BUILDING IS LIMITED TO 3.

PER TABLE 506.2, THE ALLOWABLE AREA OF A NON-SPRINKLED

GROUP B, TYPE-IIIB, BUILDING IS LIMITED TO 19,000 SQUARE

FEET.

BUILDING HEIGHT: TWO STORIES +/- 35'-0"

BUILDING PERIMETER WALLS NOT ISOLATED BY 30'-0" OR GREATER

MUST HAVE A FIRE-RESISTANCE RATING OF 1 HR MIN. (TABLE

602). EXISTING EXTERIOR WALLS CONSIST OF SOLID BRICK

EXCEEDING 6 INCHES IN THICKNESS WHICH EQUATES TO

GREATER THAN 4 HR OF RATED FIRE-RESISTENCE IN

ACCORDANCE WITH VCC TABLE 721.1(2). INFILL WITHIN THESE

WALLS WILL BE BUILT WITH A 2 HR FIRE-RESISTENCE RATING IN

ACCORDANCE WITH UL DESIGN NO. 301.

BUILDING DOES NOT CONTAIN AN AUTOMATIC SPRINKLER SYSTEM

DESIGN OCCUPANCY: TABLE 1004.1.2

BUILDING AREA (B): 2,202 SF / 150 SF PER OCCUPANT = 15

OCCUPANTS

TOTAL CALCULATED OCCUPANT LOAD: 24 (SUM OF ROOM-BY-

ROOM BASIS)

SEE LIFE SAFETY PLAN ON THIS SHEET FOR BREAKDOWN OF

OCCUPANT LOADS PER SPACE. OCCUPANT LOADS SHOWN ON

LIFE SAFETY PLANS AREA CALCULATED BY THE FOLLOWING

CALCULATION:

AREA (SF) / 150 SF PER OCCUPANT = OCCUPANT LOAD

NUMBER OF MEANS OF EGRESS - VCC TABLE 1006.3.2(2)

OCCUPANCY STORY MIN. NO. OF EXITS REQUIRED PROVIDED

BUSINESS FIRST STORY 2 2

EGRESS CAPACITY

EGRESS WIDTH CAPACITY - (VCC SECTION 1005)

LEVEL COMPONENTS AND RAMPS - 0.2 IN/PERSON

STAIRWAYS - 0.3 IN/PERSON

LEVEL COMPONENTS AND RAMPS

24 PEOPLE X 0.2 IN/PERSON = 4.8 IN. REQUIRED

(32 INCH MIN. REQUIRED)

(1 EXIT X 71.5 IN.) + (1 EXIT X 36 IN.) = 107.5 IN. PROVIDED

STAIRWAYS

24 PEOPLE X 0.3 IN/PERSON = 7.3 IN. REQUIRED

(32 INCH MIN. REQUIRED)

1 EXIT X 36 IN. = 36 IN. PROVIDED

DEAD END CORRIDORS (VCC SECTION 1020.4)

BUSINESS OCCUPANCY - MAXIMUM LENGTH = 20 FT.

COMMON PATH OF TRAVEL (VCC SECTION 1006.2.1)

BUSINESS OCCUPANCY - MAXIMUM LENGTH = 75 FT.

TOTAL TRAVEL DISTANCE TO EXITS (VCC TABLE 1017.2)

BUSINESS OCCUPANCY - MAXIMUM LENGTH = 200 FT.

REMOTENESS BETWEEN EXITS - (VCC SECTION 1007.1.1)

THE SEPARATION DISTANCE OF THE EXIT DOORS OR EXIT ACCESS DOORWAYS

SHALL BE PLACED A DISTANCE APART EQUAL TO NOT LESS THAN ONE-HALF THE

LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA

BEING SERVED, MEASURED IN A STRAIGHT LINE BETWEEN THE NEAREST EDGE OF

THE EXIT DOORS OR EXIT ACCESS DOORS.

DIAGONAL DIMENSION OF AREA BEING SERVED = 126 FT.

MINIMUM EXIT SEPARATION REQUIRED = 126 FT. / 2 = 63 FT.

EXIT SEPARATION PROVIDED = VARIES, BUT EXCEEDS MINIMUM REQUIREMENTS

PLUMBING FIXTURES - B OCCUPANCY (TABLE 2902.1)

FIXTURE

WATER CLOSET - UNISEX

LAVATORIES

DRINKING FOUNTAINS

SERVICE SINK

RATIO REQUIRED

1 PER 25 FOR THE FIRST 50

1 PER 50 FOR THE REMAINDER

1 PER 40 FOR THE FIRST 80

1 PER 80 FOR THE REMAINDER

1 PER 100

QTY. REQ.

QTY. PROVIDED

FIRE PROTECTION SYSTEMS

THE ENTIRE BUILDING IS NOT PROTECTED BY AN APPROVED AUTOMATIC WET PIPE

SPRINKLER SYSTEM.

FIRE ALARM AND DETECTION SYSTEMS

FIRE ALARM SYSTEM MODIFICATIONS TO BE A DELEGATED DESIGN ITEM. FIRE ALARM TO BE

INTERCONNECTED WITH EXISTING SYSTEM. RELOCATE EXISTING PULL STATION AND ADD

AN ADDITIONAL PULL STATION. ADD HORN/STROBES AS REQUIRED.

PORTABLE FIRE EXTINGUISHERS/CABINET LOCATIONS

PORTABLE FIRE EXTINGUISHERS SHALL BE ADDED THROUGHOUT THE BUILDING

IN LOCATIONS AS REQUIRED BY NFPA 10, NFPA 101 AND AS SHOWN.

LOCATIONS DESIGNATED AS FEC SHALL BE 1 HR FIRE RATED SEMI-RECESSED CABINETS

WITH BATTERY POWERED ALARMS. NOT TO PROTRUDE MORE THAN 4" FROM WALL.

MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER - 75 FEET

MAXIMUM AREA PER EXTINGUISHER - 11,250 SQUARE FEET

FIRE DEPARTMENT KEY BOX

THE GENERAL CONTRACTOR IS TO COORDINATE ADDING KEYS TO KNOX BOX WITH FIRE

MARSHAL.

FIRE SAFETY PLAN LEGEND

XX

XXA

FE

CALCULATED OCCUPANT LOAD

ACTUAL OCCUPANT LOAD

CAPACITY OF EGRESS COMPONENT

ACTUAL EGRESS

FIRE EXTINGUISHER

EXIT SIGN

APPROXIMATE TRAVEL DISTANCE

VIRGINIA ENERGY CODE

SECTION C402.4.1 - THE VERTICAL FENESTRATION AREA (NOT INCLUDING OPAQUE

DOORS AND OPAQUE SPANDREL PANELS)SHALL NOT EXCEED 30% OF THE GROSS

ABOVE-GRADE WALL AREA

ACTUAL FENESTRATION (INCLUDING OPAQUE DOORS AND SPANDREL PANELS) =

708 SF / 2,799 SF = 25%

TABLE C402.1.3(1) AND 402.1.3(2) - (CLIMATE ZONE 4A PER TABLE C301.1)

OPAQUE THERMAL ENVELOPE REQUIREMENTS

ROOFING

SLAB ON GRADE, UNHEATED

SWINGING OPAQUE DOORS

REQUIRED APPROXIMATE

R-30ci

R-10 FOR 24" BELOW

U-0.61

UNCHANGED

UNCHANGED

UNCHANGED

JOIST/ FRAMING FLOOR R-30 UNCHANGED

TENANT B

A

AP

PR

O X.

T R

AV

EL

D

IS

TA

N C

E

1/ 2"

F T

AP

PR

O X.

T R

TA

N C

E

F

T

FE

C

EXISTING MASONRY

FIRE WALL

TENANT A

AP

PR

O X.

T R

TA

N C

E

/2 " F

T

36024A

1 HR FIRE RATED

UL DESIGN NO. U305.

EXTEND TO DECK

AND SEAL.

FE FE

JOINTS COVERED

WITH PAPER TAPE

AND JOINT

COMPOUND. NAIL

HEADS EXPOSED

OR COVERED WITH

JOINT COMPOUND.

5/8" GPDW

2 X 4 STUDS

3" THICK BATTS AND

BLANKETS OR GLASS

FIBER INSULATION

5/8" GPDW

JOINTS COVERED

WITH PAPER TAPE

AND JOINT

COMPOUND. NAIL

HEADS EXPOSED OR

COVERED WITH JOINT

COMPOUND.

5/8" GPDW

2 X 4 STUDS

5/8" GPDWNON-BEARING WALL

PARTITION INTERSECTION.

TWO NOMINAL 2 X 4 OR

2 X 6 STUDS TO BE FLUSH

WITH STUDS ON BEARING

WALL.

3" THICK BATTS AND

BLANKETS OR GLASS

FIBER INSULATION

MAX

16" O.C.

MAX

16" O.C.

ARCHITECTURAL

REVISIONS

PROJECT NO.

SO

LE

X

AR

C H

IT

EC

TU

R

E, IN

C

M

AI

N S

TR

EE

T D

AN

VI

LL

E, V

IR

G

IN

IA

4.

8.

P H

O N

E

4.

1.

F

AX

MECHANICAL/ELECTRICAL

/PLUMBING

INSPECTION SIGN-OFF

DATE DESCRIPTION INITIAL

RENOVATION TO 206 NORTH UNION ST

N O

R

TH

U N

IO

N

S

TR

EE

T

D

AN

VI

LL

E, V

IR

G

IN

IA

2026.08.17

NORTH UNION PROPERTIES, LLC

20260025

N O

R

TH

U N

IO

N

P R

O

PE

R

TI

ES

, L

LC

R

EN

O

VA

TI

O N

T O

N O

R

TH

U N

IO

N

S T

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

Scale: 1/8" = 1'-0"G-100

FIRST FLOOR LIFE SAFETY PLAN1

DRAWINGS LIST

SHEET NO. SHEET NAME

GENERAL

G-100 TITLE SHEET & LIFE SAFETY PLAN

ARCHITECTURAL

AD-101 EXISTING & DEMO FLOOR PLANS

A-101 PROPOSED LAYOUT

A-103 REFLECTED CEILING PLAN

A-601 DOOR SCHEDULE, ELEVATIONS, AND

DETAILS AND WALL DETAILS

MECHANICAL

M-001 MECHANICAL NOTES

M-101 MECHANICAL PLAN

M-301 MECHANICAL SCHEDULES

ELECTRICAL

E-001 ELECTRICAL NOTES

E-101 DEMO PLANS

E-102 LIGHTING PLAN

E-103 POWER PLAN

E-301 PANEL SCHEDULES

E-302 POWER RISER

Scale: 3/4" = 1'-0"G-100

UL DESIGN # U305 (WALL ASSEMBLY) - 1 HOUR2

NO. DESCRIPTION DATE

UPUP

UP

UP

STORAGE

RR

E100

A102 E105 E104

E106

CLOSET

206A

STAIR

D002

D003

D004

D006

D007

D009

D008

22' - 5 1/2"

/4

/8

REMOVE AND RELOCATE

EXIT SIGN

MEZZ

DN

OPEN

BELOW

A107

D001

D002

D005

D010

7'

1/

2"

/2

9' - 0 3/4" 12' - 7 1/8"

GENERAL DEMO NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

DASHED LINES DENOTE ITEMS TO BE REMOVED.

THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH

ALL HEALTH & OCCUPATIONAL REGULATIONS REGARDING PROTECTION OF

WORKERS DURING CONSTRUCTION AND PROVIDE RECEIPT OF PROPER

DISPOSAL.

DEMOLITION SHALL BE ACCOMPANIED BY ALL SAFETY MEASURES NECESSARY

AND REQUIRED TO PROTECT WORKERS AND VISITORS AT THE SITE.

GENERAL CONTRACTORS, SUBS, SUPPLIERS, ETC. WORKING ON OR

ASSOCIATED IN ANY WAY WITH THIS PROJECT MUST ADHERE TO ALL

APPLICABLE LOCAL, STATE, AND FEDERAL LAWS, CODES, AND REGULATIONS.

THE GENERAL CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR OVERVIEW

COORDINATION WITH ALL TRADES. FAILURE TO COORDINATE WORK OF EACH

TRADE SHALL NOT BE JUSTIFICATION FOR ADDITIONAL COMPENSATION.

THE GENERAL CONTRACTOR IS REQUIRED TO NOTIFY THE A/E OF ANY

CONFLICT OF THE PLANS AND SPECIFICATIONS. FAILURE TO NOTIFY THE A/E

RESULTING IN ADDITIONAL COST SHALL BE THE GENERAL CONTRACTOR'S

EXPENSE.

IN THE EVENT A CONFLICT IS FOUND OR AN INTERPRETATION IS REQUIRED,

THE ARCHITECT SHALL RESPOND BASED ON THE OWNER'S APPROVAL.

MAINTAIN PORTIONS OF EXISTING BUILDING AFFECTED BY CONSTRUCTION

OPERATIONS IN A WEATHERTIGHT CONDITION THROUGHOUT CONSTRUCTION

PERIOD. REPAIR DAMAGE CAUSED BY DEMOLITION OPERATIONS.

NO WORK SHALL BE DONE BY CONTRACTORS THAT WILL REDUCE THE

STRUCTURAL INTEGRITY OF THE BUILDING OR ITS COMPONENTS, REDUCE

THE CURRENT LEVEL OR DEGREE OF FIRE PROTECTION OR LIFE-SAFETY

MEASURES OR CONFLICT WITH ANY APPLICABLE CODES, ORDINANCES,

REGULATIONS, REQUIREMENTS, OR INSTRUCTIONS OF INSPECTING

AUTHORITIES.

GENERAL CONTRACTOR TO MAINTAIN EXISTING EXITS DURING

CONSTRUCTION ACTIVITIES UNLESS OTHERWISE INDICATED.

THE GENERAL CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS AS

REQUIRED TO COMPLETE DEMOLITION AND REMOVAL OF ALL ITEMS AS

SHOWN OR NOTED ON DRAWINGS AND THOSE ITEMS REQUIRED TO BE

REMOVED TO FULFILL THE INTENT OF THE CONSTRUCTION DOCUMENTS.

DEMOLITION THAT INVOLVES ITEMS OR ASSEMBLIES WITH MECHANICAL,

PLUMBING, OR ELECTRICAL CONNECTIONS, SHALL HAVE SUCH CONNECTIONS

DISCONNECTED, DEACTIVATED, CAPPED, OR SEALED BY THE APPROPRIATE

CONTRACTOR IN ACCORDANCE WITH THE APPLICABLE CODES, ORDINANCES,

REGULATIONS, REQUIREMENTS, OR INSTRUCTIONS OF INSPECTING

AUTHORITIES.

ALL PLUMBING, MECHANICAL, AND ELECTRICAL INDICATED TO BE REMOVED

SHALL BE DEMOLISHED BACK TO THE SOURCE. CONTRACTOR RESPONSIBLE

FOR IDENTIFYING SOURCE LOCATION PRIOR TO BID.

THE GENERAL CONTRACTOR SHALL PROTECT AND BE RESPONSIBLE FOR THE

EXISTING STRUCTURE, FACILITIES, AND IMPROVEMENTS ADJOINING THE AREA

UNDER THIS CONTRACT. CLEAN ADJACENT STRUCTURES AND

IMPROVEMENTS OF DUST, DIRT, AND DEBRIS CAUSED BY SELECTIVE

DEMOLITION OPERATIONS. RETURN ADJACENT AREAS TO CONDITION

EXISTING BEFORE SELECTIVE DEMOLITION OPERATIONS BEGAN. ANY

DISTURBANCE OR DAMAGE TO ADJOINING PROPERTY RESULTING DIRECTLY

OR INDIRECTLY FROM THE CONTRACTOR'S OPERATIONS SHALL BE PROMPTLY

RESTORED, REPAIRED, OR REPLACED TO THE SATISFACTION OF THE OWNER

AT NO ADDITIONAL COST.

IN CASE OF DAMAGE TO EXISTING FACILITY, CONTRACTOR'S PHOTOGRAPHIC

DOCUMENTATION WILL BE BASIS FOR OWNER'S DECISION. IF CONTRACTOR

CANNOT PROVIDE DOCUMENTATION, OWNER’S DECISION WILL BE FINAL.

DEBRIS SHALL BE REMOVED FROM THE SITE PER ALL APPLICABLE

REGULATIONS. AREA TO BE SWEPT CLEAN AT THE END OF EACH DAY.

E

54321

D

C

B

A

CHECKED BY

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SO

LE

X

AR

C H

IT

EC

TU

R

E, IN

C

M

AI

N S

TR

EE

T D

AN

VI

LL

E, V

IR

G

IN

IA

4.

8.

P H

O N

E

4.

1.

F

AX

SCALE

SHEET NUMBER

SHEET INFORMATION

SHEET NAME

As indicated

AD-101

EXISTING &

DEMO FLOOR

PLANS

JMW

JLB

2026.08.17

20260025

R

EN

O

VA

TI

O

N T

O

N

O R

TH

U

N

IO

N S

T

N O

R

TH

U N

IO

N

P R

O

PE

R

TI

ES

, L

LC

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

N O

R

TH

U N

IO

N

S

TR

EE

T

D

AN

VI

LL

E, V

IR

G

IN

IA

Scale: 1/8" = 1'-0"A-501AD-101

EXISTING/DEMO FIRST FLOOR1

Scale: 1/8" = 1'-0"AD-101

EXISTING/DEMO 206 MEZZANINE2

KEYNOTES PER SHEET

NOTE DESCRIPTION

D001 MEZZANINE TO BE DEMOLISHED. REPAIR ADJACENT

WALLS, CEILING, AND FLOOR AS REQUIRED.

D002 STAIR TO MEZZANINE TO BE DEMOLISHED. REPAIR

ADJACENT WALLS AND FLOOR AS REQUIRED.

D003 PART OF PLATFORM TO BE DEMOLISHED TO MAKE SPACE

FOR NEW VESTIBULE. SEE PROPOSED.

D004 HANGING DOOR ON WALL TO BE DEMOLISHED. REPAIR

WALL AS REQUIRED.

D005 STAIR ABOVE MEZZANINE TO BE DEMOLISHED. REPAIR

ADJACENT WALLS AND CEILING AS REQUIRED.

D006 EXISTING FLOORING TO BE REMOVED ONLY AS NEEDED

FOR NEW WALLS. SAW CUT TILE AS MINIMAL AS POSSIBLE.

D007 EXISTING WALL AND DOOR TO BE DEMOLISHED. REPAIR

ADJACENT WALLS, FLOOR, AND CEILING.

D008 REMOVE ALL EXISTING DUCTWORK AND MECHANICAL

EQUIPMENT. RETURN EQUIPMENT TO OWNER. SEE

MECHANICAL.

D009 REMOVE ALL EXISTING LIGHTS, OUTLETS, AND CONDUIT

AND REINSTALL PER NEW LAYOUT. PATCH/PAINT AS

REQUIRED. SEE ELECTRICAL. RETURN ALL UNUSED

FIXTURES TO OWNER. LIGHTS ABOVE MEZZANINE TO

RECEIVE NEW WIRING AND AIRPLANE CABLES TO MATCH

MOUNTING HEIGHT OF OTHER LIGHTS.

D010 ROUTE ALL NEW REFRIGERANT LINES AND ELECTRICAL

THROUGH UTILITY CLOSET(S) ON SECOND FLOOR. SEAL

ALL PENETRATIONS WITH APPROVED FIRE CAULKING.

FLASH AND SEAL ROOF PENETRATIONS TO MAINTAIN

EXISTING WARRANTY.

UP

UP

FE

C

TENANT A

TENANT B

BACKROOM

VESTIBULE

CORR

103A 103B

A-101 A-101

103C

M

EC

H

FULL HEIGHT STUD WALL

TO CONTINUE ABOVE

STOREFRONT

PLYWOOD PLATFORM

OVER VESTIBULE

9' - 8 1/2"

21' - 10 1/4"

/8

7' - 0 1/2" 2' - 8"12' - 1 3/4"

7'

3/

8"

11' - 7"

6 3/4"

FULL HEIGHT

STUD WALL

GENERAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

GENERAL CONTRACTORS, SUBS, SUPPLIERS, ETC. WORKING ON OR ASSOCIATED IN ANY

WAY WITH THIS PROJECT MUST ADHERE TO ALL APPLICABLE LOCAL, STATE, AND

FEDERAL LAWS, CODES, AND REGULATIONS.

THE GENERAL CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR OVERVIEW

COORDINATION WITH ALL TRADES. FAILURE TO COORDINATE WORK OF EACH TRADE

SHALL NOT BE JUSTIFICATION FOR ADDITIONAL COMPENSATION.

THE GENERAL CONTRACTOR IS REQUIRED TO NOTIFY THE A/E OF ANY CONFLICT OF THE

PLANS AND SPECIFICATIONS. FAILURE TO NOTIFY THE A/E RESULTING IN ADDITIONAL

COST SHALL BE THE GENERAL CONTRACTOR'S EXPENSE.

IN THE EVENT A CONFLICT IS FOUND OR AN INTERPRETATION IS REQUIRED, THE

ARCHITECT SHALL RESPOND BASED ON THE OWNER'S APPROVAL.

CONTRACTOR RESPONSIBLE FOR VISITING SITE AS NECESSARY AND BECOMING

FAMILIAR WITH ALL REQUIREMENTS PRIOR TO BID.

CONTRACTOR RESPONSIBLE FOR CONNECTING TO EXISTING UTILITIES AND/OR

REPLACING AS SHOWN ON ENGINEERING DRAWINGS.

THE GENERAL CONTRACTOR SHALL PROTECT AND BE RESPONSIBLE FOR THE EXISTING

STRUCTURE, FACILITIES, AND IMPROVEMENTS ADJOINING THE AREA UNDER THIS

CONTRACT. CLEAN ADJACENT STRUCTURES AND IMPROVEMENTS OF DUST, DIRT, AND

DEBRIS CAUSED BY SELECTIVE DEMOLITION OPERATIONS. RETURN ADJACENT AREAS TO

CONDITION EXISTING BEFORE SELECTIVE DEMOLITION OPERATIONS BEGAN. ANY

DISTURBANCE OR DAMAGE TO ADJOINING PROPERTY RESULTING DIRECTLY OR

INDIRECTLY FROM THE CONTRACTOR'S OPERATIONS SHALL BE PROMPTLY RESTORED,

REPAIRED, OR REPLACED TO THE SATISFACTION OF THE OWNER AT NO ADDITIONAL

COST.

IN CASE OF DAMAGE TO EXISTING FACILITY, CONTRACTOR'S PHOTOGRAPHIC

DOCUMENTATION WILL BE BASIS FOR OWNER'S DECISION. IF CONTRACTOR CANNOT

PROVIDE DOCUMENTATION, OWNER'S DECISION WILL BE FINAL.

PATCH AND REPAIR CEILINGS AND WALLS ASSOCIATED WITH CONSTRUCTION

ACTIVITIES.

CONTRACTOR TO PROVIDE AND INSTALL SMOKE / CARBON MONOXIDE DETECTOR AS

PER ALL APPLICABLE CODES. (SEE ELECTRICAL)

ELEVATIONS SHOWN ON ARCHITECTURAL DRAWINGS ARE RELATIVE.

CONTRACTOR TO PROVIDE KNOX BOX. COORDINATE LOCATION WITH LOCAL FIRE

DEPARTMENT.

CONTRACTOR RESPONSIBLE FOR COORDINATING ALL MECHANICAL AND ELECTRICAL

FIXTURES, EQUIPMENT, SWITCHES, THERMOSTATS, ETC. WITH FURNISHINGS, SHELVING,

ETC.

A-601

A-101

A-601

A-101

0.

BRAKE METAL

CORNER TRIM

STUD WALL TO

CONTINUE ABOVE

NEW HEADER TO

FLOOR ABOVE.

4 1/2"

6' - 8"

3' - 1 3/4"

4 1/2"

6' - 6 7/8"

3' - 3 3/8"

NEW STUDS

AND GPDW

E

54321

D

C

B

A

CHECKED BY

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SO

LE

X

AR

C H

IT

EC

TU

R

E, IN

C

M

AI

N S

TR

EE

T D

AN

VI

LL

E, V

IR

G

IN

IA

4.

8.

P H

O N

E

4.

1.

F

AX

SCALE

SHEET NUMBER

SHEET INFORMATION

SHEET NAME

As indicated

A-101

PROPOSED

LAYOUT

JMW

JLB

2026.08.17

20260025

R

EN

O

VA

TI

O

N T

O

N

O R

TH

U

N

IO

N S

T

N O

R

TH

U N

IO

N

P R

O

PE

R

TI

ES

, L

LC

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

N O

R

TH

U N

IO

N

S

TR

EE

T

D

AN

VI

LL

E, V

IR

G

IN

IA

Scale: 1/8" = 1'-0"A-501A-101

206 PROPOSED FLOOR PLAN1

NOTE: MODIFY FA & MOVE PULL

STATION INTO VESTIBULE

Scale: 1/8" = 1'-0"A-101

206 DIMENSION PLAN2

Scale: 1/2" = 1'-0"A-101A-101

ENLARGED VESTIBULE PLAN4

REROUTE DOWNSPOUT AND REPAIR GUTTER

AS REQUIRED FOR ELECTRICAL WORK

VTR TO BE REMOVED.

VTR TO BE REMOVED

ROOF

HATCH

EXISTING

EPDM ROOF

TO REMAIN

22' - 7"

52' - 1 3/8"

112' - 8 5/8"

10' - 0 1/2"

58' - 4 7/8"

A-301

A-301

LIFT

LIFT SUPPORT COLUMNS

AND RAILS TO BE

REMOVED. CAB AND

PULLEY MECHANISM TO

BE RELOCATED IN 206.

REMOVE METAL FIRE

DOOR AND SECURE

IN OPEN POSITION

REMOVE AND REPLACE

CONCRETE FOR WASTE

LINE. EXACT ROUTING

TO BE DETERMINED.

REMOVE

EXISTING VCT

FLOORING

HATCHED BUILDING IS PART

OF SEPARATE APPLICATION

REMOVE CMU AND

BRICK INFILL. PREP

OPENING TO RECEIVE

NEW WINDOW.

MEZZANINE COLUMNS

TO BE REMOVED

NON-ORIGINAL METAL

FRAMED PARTITION TO

BE REMOVED

REMOVE NON-

ORIGINAL BLOCK

STEPS. PATCH

FLOOR AND WALL

AS REQUIRED.

CONCRETE FLOOR FROM

THIS LINE TO REAR OF

BUILDING. PLYWOOD

AND WOOD JOISTS TO

FRONT OF BUILDING.

SEWER LINE TO CONTINUE

BENEATH WOOD JOISTS

TO THE STREET

REPLACE UPPER PANE OF

STOREFRONT WITH CURVED

GLAZING TO MATCH EXISTING

EXISTING RAISED

STOREFRONT

DISPLAY WOOD

FLOOR TO BE

REFINISHED

REMOVE TRANSOME AND DOORS. PREP

OPENING TO RECEIVE NEW FIRE RATED

WALL AND DOOR. STORE / MOUNT

DOORS TO WALL AS DISPLAY.

REMOVE ASBESTOS

FLOOR TILES

UP

UP

REMOVE AND

SALVAGE DOORS

REMOVE CONCRETE

PLATFORM. PATCH

CONCRETE FLOORING

AS REQUIRED.

SAWCUT CONCRETE FLOOR TO

REMOVE WASTE LINE. INFILL

FLOORING TO MATCH ADJACENT.

REMOVE AND REPLACE

DOOR TO MATCH ADJACENT

HATCHED BUILDING IS PART

OF SEPARATE APPLICATION

REMOVE CMU AND BRICK

INFILL. PREP OPENING TO

RECEIVE NEW WINDOW.

REMOVE CMU AND BRICK

INFILL. EXTEND OPENING

TO NEW FLOOR LEVEL

AND PREP OPENING TO

RECEIVE NEW DOOR.

REMOVE NON-ORIGINAL

WOOD FRAMED OSB

WALLS AND DOOR

EXISTING FIBERBOARD

CEILING TO BE

REMOVED TO EXPOSE

TONGUE AND GROOVE

WOOD CEILING

LOWERED GPDW CEILING

TO BE REMOVED TO

EXPOSE HIGH CEILING

EXISTING LINOLEUM WALL

COVERING TO BE REMOVED

EXISTING FRAMING TO REMAIN.

FIBERBOARD WALL COVERING

TO BE REMOVED.

REMOVE SECURITY BARS

REMOVE AND REPLACE

DOOR TO MATCH EXISTING

UP

UP

LIFT

LIFT SUPPORT

COLUMNS AND RAILS

TO BE REMOVED. CAB

AND PULLEY

MECHANISM TO BE

RELOCATED IN 206.

REAR MEZZANINE

TO BE REMOVED

REMOVE CHASE.

PATCH WALL.

OPEN TO

BELOW

NON-ORIGINAL METAL

FRAMED PARTITION

TO BE REMOVED.

REMOVE CMU AND BRICK

INFILL. PREP OPENING TO

RECEIVE NEW WINDOW.

UP

LIFT

LIFT SUPPORT

COLUMNS AND RAILS

TO BE REMOVED.

CAB AND PULLEY

MECHANISM TO BE

RELOCATED IN 206.

REMOVE AND

SECURE METAL

FIRE DOOR IN

OPEN POSITION

HATCHED BUILDING IS PART

OF SEPARATE APPLICATION

REMOVE CMU AND BRICK

INFILL. PREP OPENING TO

RECEIVE NEW WINDOW.

REMOVE PARTITION,

DOOR, PLUMBING

FIXTURES, AND PIPING

DN

REMOVE AND

SECURE METAL

FIRE DOOR IN

OPEN POSITION HATCHED BUILDING IS PART

OF SEPARATE APPLICATION

REMOVE CMU AND BRICK

INFILL. PREP OPENING TO

RECEIVE NEW WINDOW.

REMOVE WOOD

FRAMING AND

METAL WIRE

STORAGE CAGE

208G

DN

NON-ORIGINAL METAL

SIGN TO BE REMOVED

EXISTING DOORS

TO BE REMOVED

REMOVE EXISTING

WINDOW AC UNIT

& PLYWOOD INFILL

AT TRANSOM

REPLACE ACRYLIC

PANE WITH GLASS.

REMOVE EXISTING

PLYWOOD INFILL

REMOVE EXISTING WINDOW AC UNIT

AND PLYWOOD INFILL AT TRANSOM

REMOVE NON-ORIGINAL HOLLOW

METAL DOOR (OUT OF VIEW)

REMOVE INFILL AT

TRANSOM (OUT OF VIEW)

REMOVE EXISTING

METAL SECURITY BARS

EXISTING DOOR TO

BE REPLACED TO

MATCH EXISTING

REMOVE CORRUGATED

METAL SIDING TO EXPOSE

PAINTED WOOD SIDING

REMOVE CORRUGATED

METAL SIDING TO EXPOSE

PAINTED WOOD SIDING REMOVE CORRUGATED METAL

SIDING TO EXPOSE PAINTED

WOOD SIDING (OUT OF VIEW)

LOCATION OF EXISTING MEZZANINE

FLOOR TO BE REMOVED

CMU / BRICK INFILL

TO BE REMOVED

CMU / BRICK INFILL TO BE REMOVED

CMU / BRICK INFILL TO BE REMOVED

NEW PLAQUE FOR

NATIONAL TRUST

FUNDING

REPLACE UPPER PANE OF

STOREFRONT WITH CURVED

GLAZING TO MATCH EXISTING

NEW GLASS TRANSOM

NEW GLASS DOORS TO

MATCH EXISTING. PAINT

DOORS AND FRAME.

REPAIR EXISTING

WINDOWS. PAINT.

EXISTING PAINTED

BRICK. REPAIR / PAINT.EXISTING PAINTED BRICK.

REPAIR / PAINT.

REPAIR EXISTING

WINDOW. PAINT.

REPAIR EXISTING WOOD

SIDING. PAINT.

REPAIR EXISTING WOOD

SIDING. PAINT.

NEW WOOD

GLASS DOOR TO

MATCH EXISTING

NEW GLASS TRANSOM

NEW GLASS TRANSOM

NEW GLASS TRANSOM

(OUT OF VIEW)

NEW WOOD GLASS

DOOR TO MATCH

EXISTING (OUT OF VIEW)

REPAIR EXTERIOR GYPSUM

CEILING IN RECESSED

ENTRANCE. PAINT.

REPAIR EXISTING WOOD

SIDING. PAINT.

NEW ALUMINUM CLAD

WOOD WINDOWS

EXISTING PAINTED

BRICK. REPAIR / PAINT.

NEW ALUMINUM CLAD

WOOD WINDOWS

NEW ALUMINUM CLAD

WOOD WINDOWS

NEW HOLLOW METAL

EMERGENCY EGRESS

DOOR. PAINT.

EXHISTING PAINTED

BRICK. REPAIR / PAINT.

VTR TO BE REMOVED.

VTR TO BE REMOVED

ROOF

HATCH

EXISTING

EPDM ROOF

TO REMAIN

22' - 7"

52' - 1 3/8"

112' - 8 5/8"

10' - 0 1/2"

58' - 4 7/8"

A-301

A-301

LIFT

LIFT SUPPORT COLUMNS

AND RAILS TO BE

REMOVED. CAB AND

PULLEY MECHANISM TO

BE RELOCATED IN 206.

REMOVE METAL FIRE

DOOR AND SECURE

IN OPEN POSITION

REMOVE AND REPLACE

CONCRETE FOR WASTE

LINE. EXACT ROUTING

TO BE DETERMINED.

REMOVE

EXISTING VCT

FLOORING

HATCHED BUILDING IS PART

OF SEPARATE APPLICATION

REMOVE CMU AND

BRICK INFILL. PREP

OPENING TO RECEIVE

NEW WINDOW.

MEZZANINE COLUMNS

TO BE REMOVED

NON-ORIGINAL METAL

FRAMED PARTITION TO

BE REMOVED

REMOVE NON-

ORIGINAL BLOCK

STEPS. PATCH

FLOOR AND WALL

AS REQUIRED.

CONCRETE FLOOR FROM

THIS LINE TO REAR OF

BUILDING. PLYWOOD

AND WOOD JOISTS TO

FRONT OF BUILDING.

SEWER LINE TO CONTINUE

BENEATH WOOD JOISTS

TO THE STREET

REPLACE UPPER PANE OF

STOREFRONT WITH CURVED

GLAZING TO MATCH EXISTING

EXISTING RAISED

STOREFRONT

DISPLAY WOOD

FLOOR TO BE

REFINISHED

REMOVE TRANSOME AND DOORS. PREP

OPENING TO RECEIVE NEW FIRE RATED

WALL AND DOOR. STORE / MOUNT

DOORS TO WALL AS DISPLAY.

REMOVE ASBESTOS

FLOOR TILES

UP

UP

REMOVE AND

SALVAGE DOORS

REMOVE CONCRETE

PLATFORM. PATCH

CONCRETE FLOORING

AS REQUIRED.

SAWCUT CONCRETE FLOOR TO

REMOVE WASTE LINE. INFILL

FLOORING TO MATCH ADJACENT.

REMOVE AND REPLACE

DOOR TO MATCH ADJACENT

HATCHED BUILDING IS PART

OF SEPARATE APPLICATION

REMOVE CMU AND BRICK

INFILL. PREP OPENING TO

RECEIVE NEW WINDOW.

REMOVE CMU AND BRICK

INFILL. EXTEND OPENING

TO NEW FLOOR LEVEL

AND PREP OPENING TO

RECEIVE NEW DOOR.

REMOVE NON-ORIGINAL

WOOD FRAMED OSB

WALLS AND DOOR

EXISTING FIBERBOARD

CEILING TO BE

REMOVED TO EXPOSE

TONGUE AND GROOVE

WOOD CEILING

LOWERED GPDW CEILING

TO BE REMOVED TO

EXPOSE HIGH CEILING

EXISTING LINOLEUM WALL

COVERING TO BE REMOVED

EXISTING FRAMING TO REMAIN.

FIBERBOARD WALL COVERING

TO BE REMOVED.

REMOVE SECURITY BARS

REMOVE AND REPLACE

DOOR TO MATCH EXISTING

UP

UP

LIFT

LIFT SUPPORT

COLUMNS AND RAILS

TO BE REMOVED. CAB

AND PULLEY

MECHANISM TO BE

RELOCATED IN 206.

REAR MEZZANINE

TO BE REMOVED

REMOVE CHASE.

PATCH WALL.

OPEN TO

BELOW

NON-ORIGINAL METAL

FRAMED PARTITION

TO BE REMOVED.

REMOVE CMU AND BRICK

INFILL. PREP OPENING TO

RECEIVE NEW WINDOW.

UP

LIFT

LIFT SUPPORT

COLUMNS AND RAILS

TO BE REMOVED.

CAB AND PULLEY

MECHANISM TO BE

RELOCATED IN 206.

REMOVE AND

SECURE METAL

FIRE DOOR IN

OPEN POSITION

HATCHED BUILDING IS PART

OF SEPARATE APPLICATION

REMOVE CMU AND BRICK

INFILL. PREP OPENING TO

RECEIVE NEW WINDOW.

REMOVE PARTITION,

DOOR, PLUMBING

FIXTURES, AND PIPING

DN

REMOVE AND

SECURE METAL

FIRE DOOR IN

OPEN POSITION HATCHED BUILDING IS PART

OF SEPARATE APPLICATION

REMOVE CMU AND BRICK

INFILL. PREP OPENING TO

RECEIVE NEW WINDOW.

REMOVE WOOD

FRAMING AND

METAL WIRE

STORAGE CAGE

208G

DN

NON-ORIGINAL METAL

SIGN TO BE REMOVED

EXISTING DOORS

TO BE REMOVED

REMOVE EXISTING

WINDOW AC UNIT

& PLYWOOD INFILL

AT TRANSOM

REPLACE ACRYLIC

PANE WITH GLASS.

REMOVE EXISTING

PLYWOOD INFILL

REMOVE EXISTING WINDOW AC UNIT

AND PLYWOOD INFILL AT TRANSOM

REMOVE NON-ORIGINAL HOLLOW

METAL DOOR (OUT OF VIEW)

REMOVE INFILL AT

TRANSOM (OUT OF VIEW)

REMOVE EXISTING

METAL SECURITY BARS

EXISTING DOOR TO

BE REPLACED TO

MATCH EXISTING

REMOVE CORRUGATED

METAL SIDING TO EXPOSE

PAINTED WOOD SIDING

REMOVE CORRUGATED

METAL SIDING TO EXPOSE

PAINTED WOOD SIDINGREMOVE CORRUGATED METAL

SIDING TO EXPOSE PAINTED

WOOD SIDING (OUT OF VIEW)

LOCATION OF EXISTING MEZZANINE

FLOOR TO BE REMOVED

CMU / BRICK INFILL

TO BE REMOVED

CMU / BRICK INFILL TO BE REMOVED

CMU / BRICK INFILL TO BE REMOVED

NEW PLAQUE FOR

NATIONAL TRUST

FUNDING

REPLACE UPPER PANE OF

STOREFRONT WITH CURVED

GLAZING TO MATCH EXISTING

NEW GLASS TRANSOM

NEW GLASS DOORS TO

MATCH EXISTING. PAINT

DOORS AND FRAME.

REPAIR EXISTING

WINDOWS. PAINT.

EXISTING PAINTED

BRICK. REPAIR / PAINT.EXISTING PAINTED BRICK.

REPAIR / PAINT.

REPAIR EXISTING

WINDOW. PAINT.

REPAIR EXISTING WOOD

SIDING. PAINT.

REPAIR EXISTING WOOD

SIDING. PAINT.

NEW WOOD

GLASS DOOR TO

MATCH EXISTING

NEW GLASS TRANSOM

NEW GLASS TRANSOM

NEW GLASS TRANSOM

(OUT OF VIEW)

NEW WOOD GLASS

DOOR TO MATCH

EXISTING (OUT OF VIEW)

REPAIR EXTERIOR GYPSUM

CEILING IN RECESSED

ENTRANCE. PAINT.

REPAIR EXISTING WOOD

SIDING. PAINT.

NEW ALUMINUM CLAD

WOOD WINDOWS

EXISTING PAINTED

BRICK. REPAIR / PAINT.

NEW ALUMINUM CLAD

WOOD WINDOWS

NEW ALUMINUM CLAD

WOOD WINDOWS

NEW HOLLOW METAL

EMERGENCY EGRESS

DOOR. PAINT.

EXHISTING PAINTED

BRICK. REPAIR / PAINT.

11' - 8 1/2"

11' - 8 1/2"

EXPOSED

CEILING

EXPOSED

CEILING

EXPOSED

CEILING

26' - 11 3/8" 26' - 11 3/8"

T&G

T&G

25' - 10 7/8"

25' - 11 1/2"

EXPOSED

CEILING

ALL EXPOSED DUCT, CONDUIT, ETC.

TO BE PAINTED TO MATCH CEILING

REDISTRIBUTE WHITE

NOISE SPEAKERS

GENERAL CEILING NOTES

1.

2.

3.

4.

5.

6.

CONTRACTOR TO COORDINATE NEW WORK WITH HVAC AND ELECTRICAL.

CONTRACTOR RESPONSIBLE COORDINATING THE INSTALLATION ALL CEILING MOUNTED FIXTURES, DIFFUSERS, ETC.

CONTRACTOR TO PERFORM FINAL SETTING OF ALL CEILING MOUNTED ITEMS. CONTRACTOR RESPONSIBLE FOR FINAL

CLEANING OF ALL CEILING MOUNTED ITEMS.

ALL CEILINGS ARE TO REMAIN AT EXISTING HEIGHTS UNLESS OTHERWISE NOTED.

CONTRACTOR TO COORDINATE ALL ABOVE CEILING TRADES TO AVOID CONFLICT.

CONTRACTOR RESPONSIBLE FOR COORDINATING ALL LAY-IN FIXTURES, DIFFUSERS, ETC.

7. CONTRACTOR RESPONSIBLE FOR PROVIDING AND INSTALLING NEW EXIT SIGNS AND EMERGENCY LIGHTING AS SHOWN.

7' - 6 1/4"

GPDW

A-103

3/4" SHEATHING

2x6 CEILING JOIST @ 16" O.C.

5/8" GPDW

SOUND ATTENUATION

BATTS

TRIM BOARD

(PAINT BLACK)

CAULK

NEW STUD WALL BEYOND

NEW STOREFRONT BEYOND

E

54321

D

C

B

A

CHECKED BY

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SO

LE

X

AR

C H

IT

EC

TU

R

E, IN

C

M

AI

N S

TR

EE

T D

AN

VI

LL

E, V

IR

G

IN

IA

4.

8.

P H

O N

E

4.

1.

F

AX

SCALE

SHEET NUMBER

SHEET INFORMATION

SHEET NAME

As indicated

A-103

REFLECTED

CEILING PLAN

KMW/JMW

JLB

2026.08.17

20260025

R

EN

O

VA

TI

O

N T

O

N

O R

TH

U

N

IO

N S

T

N O

R

TH

U N

IO

N

P R

O

PE

R

TI

ES

, L

LC

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

N O

R

TH

U N

IO

N

S

TR

EE

T

D

AN

VI

LL

E, V

IR

G

IN

IA

Scale: 1/8" = 1'-0"A-501A-103

FIRST FLOOR REFLECTED CEILING PLAN1

EXISTING

HALLWAY

Scale: 1/2" = 1'-0"A-103

VESTIBULE REFLECTED CEILING PLAN2

Scale: 3" = 1'-0"A-103A-103

STOREFRONT CEILING DETAIL3

ALL FRAMES TO BE 2"

WIDE UNLESS NOTED

OTHERWISE.

SOME OF THE FRAME

TYPES SHOWN IN

THIS LEGEND MAY

NOT BE USED IN THIS

PROJECT.

D O

O R

H

EI

G H

T

WIDTH

DOOR

F

H

EI

G H

T

WIDTH

FG

H

EI

G H

T

WIDTH

1'

0" 6"

6"6"

TYPICAL DOOR HEAD AND JAMB DETAILS

SOUND

ATTENUATION

BATTS

5/8" GPDW

CAULK CONT. ON

BOTH SIDES

H.M. FRAME - VERIFY

FRAME DEPTH BASED

ON STUD WALL SIZE

WOOD STUDS

2"

MIN. 3 ANCHORS

PER JAMB

WOOD DOOR

SOUND

ATTENUATION

BATTS

5/8" GPDW

CAULK CONT. ON

BOTH SIDES

H.M. FRAME - VERIFY

FRAME DEPTH BASED ON

STUD WALL SIZE

MIN. 3 ANCHORS

PER JAMB

WOOD STUDS

2"

WOOD DOOR

5/8" GPDW

H1

J1

H2

J2

6 3/4"

4 3/4" OR

ALUMINUM

FRAME

ALUMINUM

DOOR

STOREFRONT

GLAZING

ALUMINUM

FRAME

ALUMINUM

DOOR

STOREFRONT

GLAZING

1/ 8"

1/

2"

4 1/2"

1/8"

T

T T

1'

6"

2" 2"

5'

2"

2"1' - 3 3/4"

2"

1' - 3 3/4"

2"

3' - 0"

8'

5/

8"

/8

2"

T T

4 1/2"

6' - 8"

2"

T

T T

T T

1' - 5 1/2" 1' - 5 1/2" 2"

2" 3' - 0" 2" 2"

2"

5'

2"

2"

1'

6"

2" 7'

2"

ALL GLAZING TO RECEIVE D-H-45

6' - 6 7/8"

J1

H1

TYPICAL STOREFRONT DETAILS

CAULK CONT. ON

BOTH SIDES

SOUND ATTENUATION

BATTS (FULL HEIGHT

OF WALL)

METAL STUD @ 16"O.C.

PROVIDE 2 AT JAMB

CAULK CONT. ON

BOTH SIDES

5/8" GPDW EACH SIDE

UNLESS OTHERWISE

NOTED

2" x 4 1/2" ALUMINUM

STOREFRONT FRAME

2"x 4 1/2" ALUMINUM

STOREFRONT FRAME

5/8" GPDW

(2) 2x6 TOP PLATE

1x6 TRIM BOARD. PAINT.

(2) 2x8 RIM JOIST

5/8" GPDW

3/4" SHEATHING

2x6 CEILING JOIST @ 16" O.C.

S1

EXISTING SUBFLOOR

EXISTING FLOORING

PREFINISHED BRAKE

METAL TRIM

2" x 4 1/2" ALUMINUM

STOREFRONT FRAME

POP RIVET OR

ADHESIVE TAPE

GENERAL STOREFRONT NOTES

NOTE: T SYMBOL INDICATES PANELS OF TEMPERED / SAFETY GLAZING

E

54321

D

C

B

A

CHECKED BY

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SO

LE

X

AR

C H

IT

EC

TU

R

E, IN

C

M

AI

N S

TR

EE

T D

AN

VI

LL

E, V

IR

G

IN

IA

4.

8.

P H

O N

E

4.

1.

F

AX

SCALE

SHEET NUMBER

SHEET INFORMATION

SHEET NAME

As indicated

A-601

DOOR

SCHEDULE,

ELEVATIONS,

AND DETAILS

AND WALL

DETAILS

KMW

JLB

2026.08.17

20260025

R

EN

O

VA

TI

O

N T

O

N

O R

TH

U

N

IO

N S

T

N O

R

TH

U N

IO

N

P R

O

PE

R

TI

ES

, L

LC

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

N O

R

TH

U N

IO

N

S

TR

EE

T

D

AN

VI

LL

E, V

IR

G

IN

IA

Scale: 1/4" = 1'-0"A-601

DOOR FRAME TYPES2

Scale: 1/4" = 1'-0"A-601

DOOR PANEL TYPES1

206 DOOR SCHEDULE

D O

O R

N U

M

BE

R DOOR FRAME DETAILS

FI

R

E

LA

BE

L

H

AR

D W

AR

E

D O

O R

N U

M

BE

R

SIZE

TYPE M

AT

ER

IA

L

G

LA

ZI

N

G

TY

PE

M

AT

ER

IA

L

H

EA

D

JA

M

B

W

ID

TH

H

EI

G H

T

101 3' - 0" 7' - 0" FG AL 01 AL H2 J2 1 101

102 3' - 0" 7' - 0" FG AL D-H-45 01 AL H2 J2 45 MIN. 1 102

103A 3' - 0" 7' - 0" F HM 01 HM H1 J1 45 MIN. 2 103A

103B 3' - 0" 7' - 0" F HM 01 HM H1 J1 45 MIN. 2 103B

103C 3' - 0" 7' - 0" F HM 02 HM H1 J1 3 103C

FINISH LIST

FINISH COMMENTS

FLOOR FINISHES

GROUT (G)

G-1 MAPEI, 47 CHARCOAL, ANTHRACITE, CARBON, 1/8"

TILE (T)

T-2 EXISTING TILE FLOORING

BASE FINISHES

PAINT (PNT)

PNT-2 SHERWIN-WILLIAMS, S7006, EXTRA WHITE, SEMI-GLOSS

WALL FINISHES

PAINT (PNT)

PNT-5 SHERWIN-WILLIAMS, SW7064, PASSIVE, EGGSHELL

FINISH SCHEDULE

ROOM MATERIALS AND FINISHES

NAME NUMBER WALL MATERIAL WALL FINISH BASE MATERIAL BASE FINISH FLOOR MATERIAL FLOOR FINISH CEILING MATERIAL CEILING FINISH

VESTIBULE 100 GPDW, EXIST. PLASTER PNT-5 NEW DIMENSIONAL WOOD PNT-2 T-2, G-1 SEAL EXISTING WOOD ROOF STRUCTURE PNT-2 TENANT A 101 GPDW, EXIST. PLASTER PNT-5 NEW DIMENSIONAL WOOD PNT-2 T-2, G-1 SEAL EXISTING WOOD ROOF STRUCTURE PNT-2 TENANT B 102 GPDW, EXIST. PLASTER PNT-5 NEW DIMENSIONAL WOOD PNT-2 T-2, G-1 SEAL EXISTING WOOD ROOF STRUCTURE PNT-2

BACKROOM 103 GPDW PNT-5 NEW DIMENSIONAL WOOD PNT-2 T-2, G-1 SEAL EXISTING WOOD ROOF STRUCTURE PNT-2 MECH. 104 GPDW PNT-5 NEW DIMENSIONAL WOOD PNT-2 T-2, G-1 SEAL EXISTING WOOD ROOF STRUCTURE PNT-2

Scale: 3/4" = 1'-0"A-101A-601

RETAIL 1 VESTIBULE DOOR3

Scale: 3/4" = 1'-0"A-101A-601

RETAIL 2 VESTIBULE DOOR4

1. PROVIDE WEATHERSTRIPPING, THRESHOLD, CLOSER, PUSH/PULL BAR, AND ENTRY LOCK WITH THUMB LATCH ON INTERIOR.

2. PROVIDE WEATHERSTRIPPING, CLOSER, AND ENTRY LOCKSET.

3. PROVIDE SILENCERS AND STOREROOM LOCKSET.

4. ALL HARDWARE TO MATCH EXISTING FINISH, QUALITY, TYPE, AND KEYWAY. CONFIRM KEYING W/OWNER.

1. ALL PAINT COLORS TO MATCH EXISTING.

2. NEW WOOD BASE AND MOLDING TO MATCH EXISTING.

RECTANGULAR/SQUARE TO ROUND DUCT EQUIVALENT

RECTANGULAR DUCT ROUND DUCT

30"X26" 30"Ø

20"X26" 24"Ø

18"X18" 20"Ø

18"X20" 20"Ø

20"X16" 18"Ø

16"X16" 16"Ø

10"X16" 14"Ø

10"X20" 16"Ø

16"X14" 16"Ø

16"X12" 14"Ø

GENERAL MECHANICAL NOTES:

ADMINISTRATIVE:

1. THE FOLLOWING ABBREVIATIONS SHALL APPLY TO NOTES AND PLANS:

PC - PLUMBING CONTRACTOR,

EC - ELECTRICAL CONTRACTOR,

MC - MECHANICAL CONTRACTOR,

GC - GENERAL CONTRACTOR,

FASC - FIRE ALARM SYSTEM CONTRACTOR,

AHJ - AUTHORITY HAVING JURISDICTION.

SMC - CURRENT STATE MECHANICAL CODE (VIRGINIA MECHANICAL CODE)

SBC - CURRENT STATE BUILDING CODE (VIRGINIA CONSTRUCTION CODE)

SECC- CURRENT STATE ENERGY CONSERVATION CODE (VIRGINIA ENERGY

CONSERVATION CODE)

NFPA - NATIONAL FIRE PROTECTION ASSOCIATION

2. "PROVIDE" MEANS TO FURNISH AND INSTALL. MC SHALL ALSO INSTALL MATERIALS

FURNISHED BY OTHERS AND GENERAL CONTRACTOR AS SHOWN ON THE PLANS OR

NECESSARY FOR A COMPLETE INSTALLATION.

3. THE MC SHALL BE RESPONSIBLE FOR A COMPLETE AND OPERATING SYSTEM AS

DESCRIBED BY THESE PLANS AND SPECIFICATIONS.

4. ALL MATERIALS AND EQUIPMENT SHALL BE DELIVERED TO THE SITE AND UNLOADED

BY THE CONTRACTOR AT AN APPROVED LOCATION. THE MC SHALL PROTECT ALL

MATERIALS AND EQUIPMENT FROM BREAKAGE, THEFT, AND THE ELEMENTS. ALL

MATERIALS AND EQUIPMENT SHALL REMAIN THE PROPERTY OF THE MC UNTIL THE

PROJECT HAS BEEN COMPLETED AND TURNED OVER TO THE OWNER.

5. THE MC SHALL INSTALL ALL MATERIALS AND EQUIPMENT IN ACCORDANCE WITH THE

SMC AND SBC AND ANY APPLICABLE LOCAL CODES. WHERE A CONFLICT EXISTS

BETWEEN THE ABOVE REQUIREMENTS, THE MC SHALL OBTAIN CLARIFICATION FROM

THE ENGINEER OR IN THE EVENT ANY PART OF THESE PLANS CONFLICTS WITH THE

ABOVE REQUIREMENTS.

6. THE MC SHALL OBTAIN AND PAY FOR ALL PERMITS, FEES, AND INSPECTIONS

NECESSARY FOR THE COMPLETION OF THE WORK UNDER THIS CONTRACT.

7. DO NOT SCALE THESE DRAWINGS-REFER TO ARCHITECTURAL SHEETS FOR

DIMENSIONS.

8. THE MC SHALL VISIT THE SITE PRIOR TO BIDDING TO BECOME FAMILIAR WITH

EXISTING CONDITIONS. THE MC SHALL CONTACT THE ENGINEER TO RESOLVE ANY

DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THESE PLANS. THE MC SHALL

COORDINATE WITH OTHER TRADES PRIOR TO THE START OF CONSTRUCTION.

9. ALL MECHANICAL MATERIALS SHALL BE NEW AND FREE OF DEFECT AND LISTED AND

LABELED BY UL OR AN APPROVED THIRD-PARTY AGENCY. ANY MATERIALS FOUND TO

BE DEFECTIVE SHALL BE REPLACED BY THE MC WITHOUT ADDITIONAL COST TO THE

OWNER. WHERE A MANUFACTURER AND MODEL NUMBER IS GIVEN, THE CITED

EXAMPLE IS INTENDED TO ESTABLISH A STANDARD OF QUALITY AND NOT TO LIMIT

PRODUCTS TO A PARTICULAR MANUFACTURER. SUCH EXAMPLES ARE USED TO

CONVEY A GENERAL STYLE, TYPE, CHARACTER, AND QUALITY OF THE PRODUCT

DESIRED; PRODUCTS DETERMINED TO BE EQUAL BY THE ENGINEER WILL BE

ACCEPTED.

10. THESE PLANS ARE DIAGRAMMATIC. THE MC SHALL ADJUST THE LOCATIONS OF

EQUIPMENT, DUCTS, REGISTERS, GRILLES, ETC, TO ACCOMMODATE PLANNED AND

ENCOUNTERED INTERFERENCES. THE DRAWINGS DO NOT SHOW ALL BENDS,

OFFSETS, AND FITTINGS THAT MAY BE REQUIRED FOR A COMPLETE AND

OPERATIONAL SYSTEM. THE MC SHALL MAKE ALLOWANCES FOR SUCH DEVIATIONS

AND CONTINGENCIES IN BID TO IMPLEMENT THEM WITHOUT ADDITIONAL COST TO THE

OWNER.

11. EC SHALL BE RESPONSIBLE FOR ALL POWER CONNECTIONS TO THE MECHANICAL

EQUIPMENT. MC SHALL BE RESPONSIBLE FOR ALL CONTROL WIRING.

12. IT IS THE MC'S RESPONSIBILITY TO VERIFY THAT ITEMS FURNISHED FOR THIS

CONTRACT WILL FIT IN THE SPACE AVAILABLE. THE MC SHALL MAKE FIELD

MEASUREMENTS AS NECESSARY TO DETERMINE SPACE REQUIREMENTS. IF THE MC

MUST ALTER EQUIPMENT DUE TO SPACE CONSIDERATIONS, THE MC SHALL PROVIDE

SIZES AND SHAPES THAT FIT THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS.

13. MC SHALL COORDINATE WITH THE EC REGARDING THE ELECTRICAL REQUIREMENTS

OF ALL EQUIPMENT BEING PROVIDED.

14. MAINTAIN CLEARANCES FOR ALL EQUIPMENT ACCORDING TO MANUFACTURER'S

RECOMMENDATIONS FOR SERVICEABILITY. ALL ROOFTOP EQUIPMENT MUST BE A

MINIMUM OF 10 FEET FROM ROOF EDGE.

15. MC SHALL FURNISH A BOUND SET OF OPERATING AND MAINTENANCE INSTRUCTIONS

FOR ALL EQUIPMENT TO THE OWNER UPON COMPLETION OF THE PROJECT. MC SHALL

PROVIDE ALL DOCUMENTATION TO THE OWNER AS NECESSARY TO SUBMIT FOR

FACTORY WARRANTIES.

16. CONTRACTOR SHALL PROTECT ALL HVAC EQUIPMENT FROM CONSTRUCTION AND

SHEET ROCK DUST DURING CONSTRUCTION. ALL FILTERS SHALL BE REPLACED WITH

NEW AT THE COMPLETION OF THE PROJECT.

17. ALL EQUIPMENT INSTALLED ON ROOF MUST BE WITHIN THE ROOF SCREEN.

18. IF A ROOF PENETRATION IS REQUIRED AND THE ROOF IS UNDER WARRANTY, USE THE

AUTHORIZED ROOFER. PROVIDE DOCUMENTATION.

19. ALL PIPING, WIRING, CONDUIT, INSULATION, EQUIPMENT, SUPPORTS, ETC. SHALL BE

SUITABLE FOR INSTALLATION IN A RETURN PLENUM AS NECESSARY. COORDINATE

WITH OTHER TRADES ON LOCATIONS OF ALL PLENUMS.

20. MC SHALL COORDINATE WITH THE GENERAL CONTRACTOR TO ENSURE ALL

APPLICABLE CONSTRUCTION WASTE IS RECYCLED DURING THE CONSTRUCTION

PHASE OF THE PROJECT.

21. THE MC SHALL VERIFY THE FUNCTIONALITY AND OPERATION OF ALL EXISTING

MECHANICAL EQUIPMENT IN THE AREA OF WORK. REPLACE FILTERS, LEAK TEST AND

RECHARGE REFRIGERANT LINES, REPLACE OR LUBRICATE BEARINGS, CHECK

LINKAGES AND ACTUATORS, AND PERFORM OTHER MAINTENANCE SERVICE AS

NECESSARY TO GET THE EQUIPMENT IN PROPER ORDER.

METHODS:

1. INSULATE DUCTWORK WITH FIBERGLASS DUCT WRAP; INSTALLED R-VALUE SHALL BE

A MINIMUM R-6. COVERINGS AND LININGS, INCLUDING ADHESIVES WHEN USED, SHALL

HAVE A FLAME SPREAD INDEX NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX

NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84. ALL NEW

DUCTWORK SHALL RECEIVE INSULATION ON THE OUTSIDE. INSTALL DUCT WRAP

INSULATION WITH FACING OUTSIDE SO THAT TAPE FLAP OVERLAPS INSULATION AND

FACING OF ADJACENT PIECE OF DUCT WRAP. INSULATION SHALL BE TIGHTLY BUTTED.

FOR RECTANGULAR DUCTS, INSTALL SO INSULATION IS NOT EXCESSIVELY

COMPRESSED AT DUCT CORNERS. STAPLE SEAMS APPROXIMATELY 6 INCHES ON

CENTER WITH OUTWARD CLINCHING STAPLES. SEAL SEAMS WITH PRESSURE

SENSITIVE TAPE MATCHING THE FACING. FOR RECTANGULAR DUCTS 24 INCHES IN

WIDTH OR GREATER, SECURE DUCT WRAP TO THE BOTTOM OF THE DUCT WITH

MECHANICAL FASTENERS SPACED 18 INCHES ON CENTER TO PREVENT SAGGING OF

INSULATION. ADJACENT SECTIONS OF DUCT WRAP SHALL BE TIGHTLY BUTTED WITH

THE 2 INCH TAPE FLAP OVERLAPPING. ALL TEARS, PUNCTURES, ETC. OF THE DUCT

WRAP INSULATION SHALL BE SEALED WITH TAPE OR MASTIC TO PROVIDE A VAPOR

TIGHT SYSTEM. INSULATION SHALL BE BY KNAUF INSULATION, OWENS CORNING

CORP, OR CERTAINTEED CORPORATION.

2. VERIFY THAT DUCTS HAVE BEEN TESTED BEFORE APPLYING INSULATION MATERIALS.

VERIFY THAT DUCT SURFACES ARE CLEAN, DRY AND FREE OF FOREIGN MATERIAL

PRIOR TO INSULATING. DUCT COVERINGS SHALL NOT PENETRATE A WALL OR FLOOR

REQUIRED TO HAVE A FIRE-RESISTANCE RATING OR REQUIRED TO BE FIRE BLOCKED.

3. WHERE DUCTS ARE CONNECTED TO EXTERIOR WALL LOUVERS AND DUCT OUTLET IS

SMALLER THAN LOUVER FRAME, PROVIDE BLANK-OUT PANELS SEALING LOUVER AREA

AROUND DUCT. USE SAME MATERIAL AS DUCT, PAINTED BLACK ON EXTERIOR SIDE.

SEAL TO LOUVER FRAME AND DUCT.

4. PROVIDE DUCT ACCESS DOORS FOR INSPECTION AND CLEANING BEFORE AND AFTER

FILTERS, COILS, FANS, AUTOMATIC DAMPERS, AT FIRE DAMPERS, COMBINATION FIRE

AND SMOKE DAMPERS.

5. CONSTRUCT T's, BENDS, AND ELBOWS WITH RADII OF NOT LESS THAN 1-1/2 TIMES THE

WIDTH OF THE DUCT ON CENTERLINE. WHERE NOT POSSIBLE AND WHERE

RECTANGULAR ELBOWS MUST BE USED, PROVIDE TURNING VANES.

6. INCREASE DUCT SIZES GRADUALLY, NOT EXCEEDING 15 DEGREES DIVERGENCE;

MAXIMUM OF 30 DEGREES DIVERGENCE UPSTREAM OF EQUIPMENT AND 45 DEGREES

CONVERGENCE DOWNSTREAM.

7. IT SHALL BE THE RESPONSIBILITY OF THE MC TO SUSPEND AND SUPPORT ALL

EQUIPMENT, DUCTWORK, DIFFUSERS, AND OTHER MATERIALS FOLLOWING

RECOGNIZED ENGINEERING PRACTICES AND USING STANDARD, COMMERCIALLY

ACCEPTED HANGERS AND SUSPENSION EQUIPMENT. ALL HVAC EQUIPMENT SHALL BE

SECURELY MOUNTED TO THE BUILDING STRUCTURE AND SHALL NOT RELY ON

CEILING OR WALL SURFACES FOR SUPPORT. THE SUPPORT ATTACHMENT SHALL

SUPPORT THE WEIGHT OF THE EQUIPMENT PLUS THE WEIGHT OF THE SUPPORT

ATTACHMENT ITSELF. SUPPORT FROM THE TOP CHORD OF THE ROOF JOISTS,

GIRDERS, AND BEAMS. THE BOTTOM CHORD IS NOT TO BE USED FOR EQUIPMENT OR

PIPING SUPPORT. HANGERS SHALL NOT BE ATTACHED TO CORRUGATED STEEL

DECKING.

8. DUCTS SHALL BE SUPPORTED IN ACCORDANCE WITH SMACNA AT INTERVALS NOT

EXCEEDING 10 FEET. DUCTS 36 INCHES OR LARGER SHALL HAVE TRAPEZE TYPE

HANGERS SUSPENDED WITH THREADED ROD. SUPPORT DUCTS FROM BAR JOISTS,

GIRDERS, OR BEAMS.

9. CHECK LOCATIONS OF AIR OUTLETS AND INLETS AND MAKE NECESSARY

ADJUSTMENTS IN POSITION TO CONFORM WITH ARCHITECTURAL FEATURES,

SYMMETRY, AND LIGHTING ARRANGEMENT. COORDINATE WITH SPRINKLER

CONTRACTOR IF APPLICABLE.

10. PROVIDE BALANCING DAMPERS AT POINTS ON SUPPLY WHERE BRANCHES ARE TAKEN

FROM LARGER DUCTS AS REQUIRED FOR AIR BALANCING. INSTALL MINIMUM 2 DUCT

WIDTHS FROM DUCT TAKE-OFF. PROVIDE BALANCING DAMPERS ON DUCT TAKE-OFFS

TO DIFFUSERS AND REGISTERS, REGARDLESS OF WHETHER DAMPERS ARE

SPECIFIED AS PART OF THE DIFFUSER OR REGISTER ASSEMBLY. ADJUST AIR

HANDLING AND DISTRIBUTION SYSTEMS TO PROVIDE DESIGN SUPPLY, RETURN, AND

EXHAUST AIR QUANTITIES AT SITE ALTITUDE.

11. MC SHALL INSTALL PROGRAMMABLE THERMOSTATS AS SHOWN ON THE PLANS.

THERMOSTAT SHALL BE MOUNTED AT 48 INCHES AFF. THERMOSTATS SHALL MEET

THE REQUIREMENTS FOR THERMOSTATIC CONTROLS IN SECTION C403 OF THE SECC.

12. FRESH AIR INTAKES SHALL BE INSTALLED ON ALL UNITS AS SHOWN ON DRAWINGS.

MAINTAIN 10 FEET OF DISTANCE BETWEEN FRESH AIR INTAKES AND ALL EXHAUST

TERMINATIONS AND PLUMBING VENT THRU ROOFS.

13. MC SHALL INSTALL ALL EXHAUST FANS AND VENT TO THE BUILDING'S EXTERIOR. EC

SHALL SWITCH FANS WITH LIGHTS OR ON SEPARATE SWITCH AS SHOWN.

14. P-TRAPS MUST BE INSTALLED ON ALL UNITS. MC SHALL INSTALL AUXILIARY DRAIN

PANS UNDER OVERHEAD AIR HANDLERS AND AN AUTOMATIC CUT-OFF FLOAT SWITCH

FOR EACH. P-TRAPS AND CONDENSATE LINES SHALL BE 1 INCH. P-TRAPS AND

CONDENSATE LINES MAY BE PVC WHERE NOT LOCATED IN PLENUMS; OTHERWISE,

THEY SHALL BE TYPE M COPPER.

15. INSTALL BACKDRAFT DAMPERS ON FRESH AIR AND EXHAUST DUCTS WHERE THEY

PENETRATE THE THERMAL ENVELOPE PER SECC C402.5.7

16. DUCTS CONNECTING TO A FURNACE SHALL HAVE A CLEARANCE TO COMBUSTIBLES IN

ACCORDANCE WITH THE FURNACE MANUFACTURER'S INSTALLATION INSTRUCTIONS.

17. FOR STRUCTURES IN FLOOD HAZARD AREAS, DUCTS SHALL BE LOCATED ABOVE THE

DESIGN FLOOD ELEVATION. DUCT SHALL NOT BE INSTALLED IN OR WITHIN 4 INCHES

OF THE EARTH.

18. MC SHALL INSTALL FIRE DAMPERS AT EACH PENETRATION OF A RATED WALL AS

INDICATED ON THE DRAWINGS OR AS REQUIRED BY THE AUTHORITY HAVING

JURISDICTION. FIRE DAMPERS SHALL BE UL LABELED (UL 555), CURTAIN TYPE, WITH

INTEGRAL FACTORY SLEEVE AND BLADES LOCATED OUTSIDE THE AIR STREAM.

INSTALLATION OF ALL FIRE DAMPERS SHALL BE IN ACCORDANCE WITH THE

MANUFACTURER'S INSTALLATION INSTRUCTIONS AND SECTION 607 OF THE SMC.

PROVIDE ACCESS PANELS FOR TESTING AND SERVICE AS NECESSARY. MC SHALL

PROVIDE RADIATION DAMPERS AND THERMAL BLANKETS FOR ALL PENETRATIONS OF

RATED CEILING ASSEMBLIES. RADIATION DAMPERS SHALL BE UL LABELED (UL 555C)

AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFIC

INSTALLATION INSTRUCTIONS. FIRE DAMPERS, COMBINATION FIRE/SMOKE DAMPERS,

AND CEILING RADIATION DAMPERS SHALL BE BY RUSKIN, NAILOR, OR LLOYD

INDUSTRIES.

19. MC SHALL INSTALL A SMOKE DETECTOR-UL LISTED FOR DUCT INSTALLATION (UL 268A)

IN EACH UNIT'S RETURN UPSTREAM OF ANY FILTERS, OUTSIDE AIR CONNECTIONS, OR

DECONTAMINATION EQUIPMENT. DUCT SMOKE DETECTORS SHALL BE INSTALLED IN

ACCORDANCE WITH NFPA 72. DUCT SMOKE DETECTOR SUPERVISION SHALL COMPLY

WITH 606.4.1 OF THE SMC. IF THE BUILDING IS (TO BE) EQUIPPED WITH A FIRE ALARM

SYSTEM, THE FIRE ALARM SYSTEM CONTRACTOR SHALL FURNISH AND WIRE ALL DUCT

SMOKE DETECTORS. IF THE BUILDING IS NOT PROVIDED WITH A FIRE ALARM SYSTEM,

THE MC SHALL FURNISH AND WIRE THE DUCT SMOKE DETECTORS AND A/V DEVICE. IT

SHALL BE THE RESPONSIBILITY OF THE MC TO INSTALL ALL SMOKE DUCT DETECTORS

PER NFPA AND MFG'S INSTALLATION INSTRUCTIONS REGARDLESS OF WHO

FURNISHES THE DEVICES.

20. UNITS PROVIDED WITH ECONOMIZERS SHALL ALSO BE PROVIDED WITH POWERED

EXHAUST AND COMPARATIVE ENTHALPY CONTROLS.

MATERIALS:

1. THE MC SHALL PROVIDE ALL HEATING AND COOLING EQUIPMENT AS SCHEDULED ON

THE DRAWINGS. ALTERNATES SHALL BE FROM MANUFACTURERS LISTED IN

SCHEDULES. THE MC SHALL PROVIDE FACTORY AND FIELD INSTALLED ACCESSORIES

AS SCHEDULED OR AS NECESSARY FOR A COMPLETE AND OPERATIONAL HVAC

SYSTEM.

2. THE MC SHALL PROVIDE ALL EXHAUST AND SUPPLY FANS AS SCHEDULED OR BY

EQUALS LISTED.

3. DUCTWORK IS SHOWN WITH FREE AREA DIMENSIONS. ALL DUCTWORK SHALL BE

FABRICATED AND INSTALLED IN ACCORDANCE WITH SMACNA LOW PRESSURE DUCT

STANDARD, 2 INCH S.P.

4. EXTERNAL DUCT INSULATION AND FACTORY-INSULATED FLEXIBLE DUCT SHALL BE

LEGIBLY PRINTED OR IDENTIFIED AT INTERVALS NOT GREATER THAN 36 INCHES WITH

THE NAME OF THE MANUFACTURER, THE THERMAL RESISTANCE R-VALUE AT THE

SPECIFIED INSTALLED THICKNESS AND THE FLAME SPREAD AND SMOKE-DEVELOPED

INDEXES OF THE COMPOSITE MATERIALS. ALL DUCT INSULATION PRODUCT R-VALUES

SHALL BE BASED ON INSULATION ONLY, EXCLUDING AIR FILMS, VAPOR RETARDERS

OR OTHER DUCT COMPONENTS, AND SHALL BE BASED ON TESTED C-VALUES AT 75ºF

MEAN TEMPERATURE AT THE INSTALLED THICKNESS, IN ACCORDANCE WITH

RECOGNIZED INDUSTRY PROCEDURES. THE INSTALLED THICKNESS OF DUCT

INSULATION USED TO DETERMINE ITS R-VALUES SHALL BE DETERMINED AS FOLLOWS:

4.1. FOR DUCT BOARD, DUCT LINER AND FACTORY-MADE RIGID DUCTS NOT

NORMALLY SUBJECTED TO COMPRESSION, THE NOMINAL INSULATION THICKNESS

SHALL BE USED.

4.2. FOR DUCT WRAP, THE INSTALLED THICKNESS SHALL BE ASSUMED TO BE 75

PERCENT (25-PERCENT COMPRESSION) OF NOMINAL THICKNESS.

4.3. FOR FACTORY-MADE FLEXIBLE AIR DUCTS, THE INSTALLED THICKNESS SHALL

BE DETERMINED BY DIVIDING THE DIFFERENCE BETWEEN THE ACTUAL OUTSIDE

DIAMETER AND NOMINAL INSIDE DIAMETER BY TWO.

5. ALL INSULATION CONTAINING FIBROUS MATERIALS EXPOSED TO AIRFLOW SHALL BE

RATED FOR THAT EXPOSURE OR SHALL BE ENCAPSULATED. INSULATING PROPERTIES

FOR ALL MATERIALS SHALL MEET OR EXCEED INDUSTRY STANDARDS. POLYSTYRENE

PRODUCTS SHALL MEET ASTM C578. ALL INSULATION SHALL HAVE FORMALDEHYDE

EMISSIONS NOT GREATER THAN 0.05 PPM. THE MAXIMUM FLAME SPREAD AND SMOKE

DEVELOPED INDEX FOR INSULATION SHALL MEET THE REQUIREMENTS OF THE LOCAL

CODES AND ORDINANCES ADOPTED BY THE JURISDICTION IN WHICH THE BUILDING IS

LOCATED.

6. MASTIC USED TO SEAL DUCTWORK SHALL BE LISTED AND LABELED IN ACCORDANCE

WITH UL 181A OR UL 181B MAINTAIN AMBIENT TEMPERATURES AND CONDITIONS

REQUIRED BY MANUFACTURER OF ADHESIVES, MASTICS, AND INSULATION CEMENTS.

DO NOT INSTALL DUCT SEALANT WHEN TEMPERATURES ARE LESS THAT THOSE

RECOMMENDED BY THE SEALANT MANUFACTURER.

7. ALL ADHESIVES AND SEALANTS SHALL HAVE VOC CONTENT BELOW 20 GRAMS PER

LITER AND WHICH MEET THE REQUIREMENTS OF THE MANUFACTURER OF THE

PRODUCTS BEING ADHERED OR INVOLVED. ADHESIVES AND SEALANTS SHALL

CONTAIN NO HEAVY METALS OR FORMALDEHYDE.

8. FACTORY-MADE AIR DUCTS AND CONNECTORS SHALL COMPLY WITH UL 181.

9. FLEXIBLE DUCT SHALL BE UL LISTED CLASS 0 OR CLASS 1, INSULATED, AND COMPLY

WITH UL 181. FLEXIBLE DUCT SHALL BE FACTORY FORMED, COMPOSED OF SPIRAL

WOUND CORROSION RESISTANT WIRE BONDED TO AN INNER FABRIC LINER. DUCT

SHALL BE FACTORY INSULATED WITH A FOIL VAPOR BARRIER JACKET. CONNECT TO

RIGID DUCT WITH SPIN-IN FITTING AND DAMPER. FLEXIBLE DUCTS AND AIR

CONNECTORS SHALL NOT PASS THROUGH ANY FIRE RESISTANCE RATED ASSEMBLY.

10. THE MC SHALL PROVIDE ALL DIFFUSERS GRILLES, LOUVERS, AND OTHER AIR

DISTRIBUTION OUTLETS AND INLETS. LOUVERS, GRILLES, AND DIFFUSERS SHALL BE

INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION

INSTRUCTIONS. FOR LAY-IN CEILINGS, INSTALL SUPPORT FROM THE STRUCTURE FOR

EACH DIFFUSER OR DAMPER. AIR DISTRIBUTION OUTLETS AND INLETS SHALL BE AS

SCHEDULE OR ALTERNATES LISTED.

11. AIR FILTERS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 605 OF THE SMC

12. THE MC SHALL PROVIDE ALL REFRIGERATION PIPING. ALL PIPE AND FITTINGS SHALL

BE TYPE ACR HARD COPPER TUBING WITH SWEAT FITTINGS. REFRIGERATION LINES

SHALL BE RUN NEATLY. WHERE A GROUP OF LINES ARE RUN, TRAPEZE HANGERS MAY

BE USED. DO NOT USE CHAIN OR WIRE HANGERS. WRAP TUBING WITH RUBBER TAPE

AT EACH CLAMP OR HANGER. FOR COVERED PIPES, HANGERS SHALL FIT AROUND THE

OUTSIDE OF THE COVERING WITH 12 GAUGE GALVANIZED STEEL SHIELDS OF A

LENGTH EQUAL TO THE OUTSIDE DIAMETER OF THE INSULATION AND COVERING 3/4

OF THE CIRCUMFERENCE OF THE INSULATION. SAGS SHALL NOT BE PERMISSIBLE.

HORIZONTAL LINES SHALL PITCH DOWN NOT LESS THAN 1 INCH IN 40 FEET. INSULATE

WITH 1 INCH CLOSED CELL ARMAFLEX TYPE INSULATION WITH A FLAME DENSITY

RATING LESS THAN 25 AND A SMOKE DENSITY RATING LESS THAN 50. ALL JOINTS AND

SPLICES IN INSULATION SHALL BE TAPED AND AIRTIGHT. SOLDER REFRIGERATION

LINES USING 15 PERCENT SILVER SOLDER AND EVACUATE LINES TO 300 MICRONS.

PROVIDE MOISTURE INDICATING SIGHT GLASS AND FILTER DRYER IN LIQUID LINE.

PROVIDE OIL TRAPS AND DOUBLE RISERS IN REFRIGERANT SUCTION AND HOT GAS

LINES WHERE REQUIRED TO PREVENT OIL SLUGGING AT THE COMPRESSOR AND

INSURE PROPER LUBRICATION. MC SHALL BE RESPONSIBLE FOR SEALING LINE SET

PENETRATIONS OF ANY RATED ASSEMBLIES IN ACCORDANCE WITH A SYSTEM LISTED

IN THE UL DIRECTORY FOR THE SPECIFIC ASSEMBLY BEING PENETRATED. SEE

ARCHITECTURAL PLANS FOR A LIST OF ALL UL FIRE RATED ASSEMBLIES.

13. DUCT LINER MAY BE SUBSTITUTED FOR EXTERIOR DUCT WRAP. DUCT LINER

INSULATION MATERIALS SHALL MEET THE REQUIREMENTS OF ASTM C 1071, AND ASTM

G 21. EXTERIOR DUCT R-VALUE AND INTERIOR R-VALUE SHALL BE IN ACCORDANCE

WITH THE SECC. NOMINAL DUCT SIZES SHALL BE ADJUSTED AS NECESSARY SO THAT

FREE AREA DIMENSIONS ARE PRESERVED AS SHOWN ON THE PLANS. FABRICATION

AND INSTALLATION SHALL CONFORM TO THE MANUFACTURER'S INSTALLATION

RECOMMENDATIONS AND TO THE REQUIREMENTS OF THE LATEST EDITION OF THE

NORTH AMERICAN INSULATION MANUFACTURERS ASSOCIATION FIBROUS GLASS DUCT

LINER STANDARDS AND/OR SMACNA HVAC DUCT CONSTRUCTION STANDARDS. DUCT

LINER SHALL HAVE A BLACK PIGMENTED MAT ON THE AIRSTREAM SIDE TO RESIST

DAMAGE DURING INSTALLATION AND SERVICE. EDGES SHALL BE FACTORY COATED

WITH BLACK PIGMENTED COATING TO COMPLY WITH SMACNA DCS REQUIREMENTS.

ALL PORTIONS OF DUCT DESIGNATED TO RECEIVE DUCT LINER SHALL BE

COMPLETELY COVERED WITH DUCT LINER. TRANSVERSE JOINTS SHALL BE NEATLY

BUTTED AND THERE SHALL BE NO INTERRUPTIONS OR GAPS. THE BLACK PIGMENTED

OR MAT FACED SURFACES SHALL FACE THE AIRSTREAM. DUCT LINER SHALL BE

ADHERED TO THE SHEET METAL WITH 90 PERCENT COVERAGE OF ADHESIVE

COMPLYING WITH REQUIREMENTS OF ASTM C 916. ALL EXPOSED LEADING EDGES AND

TRANSVERSE JOINTS SHALL BE FACTORY COATED OR COATED WITH ADHESIVE

DURING FABRICATION. DUCT LINER SHALL BE ADDITIONALLY SECURED WITH

MECHANICAL FASTENERS, EITHER WELD-SECURED OR IMPACT DRIVEN, WHICH SHALL

COMPRESS THE DUCT LINER SUFFICIENTLY TO HOLD IT FIRMLY IN PLACE. ADHESIVE

BONDED PINS ARE NOT PERMITTED DUE TO LONG-TERM ADHESIVE AGING

CHARACTERISTICS. LININGS SHALL BE INTERRUPTED AT THE AREA OF OPERATION OF

A FIRE DAMPER AND AT A MINIMUM OF 6 INCHES UPSTREAM AND 6 INCHES

DOWNSTREAM OF ELECTRIC RESISTANCE AND FUEL-BURNING HEATERS IN A DUCT

SYSTEM. METAL NOSINGS OR SLEEVES SHALL BE INSTALLED OVER EXPOSED DUCT

LINER THAT FACE OPPOSITE THE DIRECTION OF AIRFLOW. UPON COMPLETION OF

INSTALLATION OF DUCT LINER AND BEFORE OPERATION IS TO COMMENCE, VISUALLY

INSPECT SYSTEM AND VERIFY THAT THE DUCT LINER IS PROPERLY INSTALLED. OPEN

ALL SYSTEM DAMPERS AND TURN ON FANS TO BLOW ALL SCRAPS AND OTHER LOOSE

PIECES OF MATERIAL OUT OF THE DUCT SYSTEM. ALLOW FOR A MEANS OF REMOVAL

OF SUCH MATERIAL.

E

54321

D

C

B

A

SO

LE

X

AR

C H

IT

EC

TU

R

E, IN

C

M

AI

N S

TR

EE

T D

AN

VI

LL

E, V

IR

G

IN

IA

4.

8.

P H

O N

E

4.

1.

F

AX

SHEET NUMBER

CHECKED BY

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SCALE

SHEET INFORMATION

SHEET NAME

NO. DESCRIPTION DATE

MWK

5 Y oun g S

t. S uit e C , H end ers on, NC ww w.k ilia nen gin eer ing

.co m |

(P ) 2

.43

8.8

CO

RP

OR

ATE

LIC

EN

SE

EC

A5

/REW

MECHANICAL

NOTES

2026-0769.0000

08/17/2026

JDD

M-001

N O

R

TH

U N

IO

N

P R

O

PE

R

TI

ES

, L

LC

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

N O

R

TH

U N

IO

N

S

TR

EE

T

D

AN

VI

LL

E, V

IR

G

IN

IA

R

EN

O

VA

TI

O

N T

O

N

O R

TH

U

N

IO

N S

T.

8/17/26

UP

FE

C

BACKROOM

RETAIL 1 RETAIL 2

AHU-1

AHU-2

A

A

A

A

A

A

R1

R1

A

A

A

A

A

A

"Ø

S

PI

R

AL

"Ø

S

PI

R

AL

"Ø

S

PI

R

AL

"Ø

S

PI

R

AL

"Ø

S

PI

R

AL

"Ø

S

PI

R

AL

HP-1 HP-2

"Ø

S

PI

R

AL

16"Ø

T T

AHU-1 AHU-2

3 4

A

R2 10010

UP

UP

UP

UP

MECHANICAL PLAN HEX NOTES

1. AHU-1 TO BE VERTICALLY MOUNTED IN

CLOSET, MC TO INSTALL WITH

GALVANIZED STEEL DRAIN PAN PER

MANUFACTURER'S INSTRUCTIONS. ROUTE

CONDENSATE TO HUB DRAIN & PROVIDE

CONDENSATE PUMP.

2. AHU-2 TO BE LOCATED IN ATTIC SPACE

ABOVE BATHROOM AREA, INSTALL WITH

GALVANIZED STEEL DRAIN PAN PER

MANUFACTURER'S INSTRUCTIONS.ROUTE

CONDENSATE TO HUB DRAIN & PROVIDE

CONDENSATE PUMP.

3. RETURN GRILLE TO BE MOUNTED AT 18"

A.F.F. ROUTE TO UNIT USING 16"Ø DUCT.

4. RETURN GRILLE TO BE MOUNTED AT 108"

A.F.F. VERIFY MOUNTING HEIGHT ON SITE.

5. RETURN & SUPPLY DUCT TO BE DOUBLE

WALL SPIRAL DUCT, PAINT GRIP METAL

WHILE PASSING THROUGH BACKROOM.

6. DUCT IN RETAIL SPACE TO BE DOUBLE

WALL SPIRAL DUCT, PAINT GRIP METAL.

7. SUPPLY DUCT TO BE RUN OVERHEAD AT

12" BELOW CEILING HEIGHT.

8. DIFFUSER TO BE ANGLED AT 45° FACING

DOWNWARDS.

9. HP-1 & HP-2 TO BE LOCATED ON ROOF,

SHOWN HERE FOR CONVENIENCE.

REFRIGERANT LINE AND POWER FOR

ROOFTOP EQUIPMENT TO BE ROUTED

THROUGH UTILITY CLOSETS ON SECOND

FLOOR. SEAL ALL FLOOR PENETRATIONS

AND FLASH THE ROOF TO MAINTAIN

EXISTING WARRANTY

10. ROUTE AHU-1 & AHU-2 FRESH AIR DUCT

TO EXISTING 10" FRESH AIR DUCT IN

SPACE. MC TO INSTALL BACK DRAFT

DAMPER IN EACH UNITS INDIVIDUAL DUCT

PRIOR TO BRANCH CONNECTION.

E

54321

D

C

B

A

SO

LE

X

AR

C H

IT

EC

TU

R

E, IN

C

M

AI

N S

TR

EE

T D

AN

VI

LL

E, V

IR

G

IN

IA

4.

8.

P H

O N

E

4.

1.

F

AX

SHEET NUMBER

CHECKED BY

DRAWN BY

DATE

PROJECT NO.

REVISIONS

SCALE

SHEET INFORMATION

SHEET NAME

NO. DESCRIPTION DATE

MWK

5 Y oun g S

t. S uit e C , H end ers on, NC ww w.k ilia nen gin eer ing

.co m |

(P ) 2

.43

8.8

CO

RP

OR

ATE

LIC

EN

SE

EC

A5

/REW

MECHANICAL

PLAN

2026-0769.0000

08/17/2026

JDD

M-101

N O

R

TH

U N

IO

N

P R

O

PE

R

TI

ES

, L

LC

C O

N

ST

R U

C

TI

O N

D O

C…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .