Generator Replacement for Collin County Adult Detention Facility (CCADF) Cluster 1
Solicitation number
2026-065
Issued by
Collin County, Texas

About this file

This is a set of electrical construction documents for a generator replacement project at the Collin County Adult Detention Facility (CCADF) Cluster 1 in McKinney, Texas (Project No. 251780). The project involves replacing an existing 500 kW diesel generator with a new 500 kW diesel generator operating at 480Y/277 volts, three-phase, four-wire configuration. The scope of work includes installing power, control, and fuel connections; connecting control signals from three existing automatic transfer switches (ATS); installing fuel piping from an adjacent existing fuel tank with a low-fuel float switch on a new sub-base tank; performing full-load testing with a temporary load bank; removing and disposing of the existing generator as directed by the owner; and providing a temporary generator with cables and fuel during the replacement period. The project is located at 4300 Community Avenue, McKinney, Texas 75071, within Cluster 1's electric room. The construction documents are dated September 24, 2025, and include electrical legends, one-line diagrams, schedules, enlarged plans, and site photographs documenting the existing generator installation and connections.

The probable construction cost for this project is four hundred thousand dollars ($400,000.00). All work must comply with the 2023 National Electric Code, 2021 International Mechanical Code, 2021 International Energy Conservation Code, 2021 International Building Code, state and local amendments, National Fire Protection Association standards, and Underwriters Laboratories or ETL requirements. The electrical contractor is responsible for obtaining all necessary permits and fees from the authority having jurisdiction, coordinating with all trades to verify underground utility locations before digging, and protecting permanent building fixtures from construction damage. The contractor must calculate voltage drop for branch circuits exceeding 75 feet in length to ensure no more than 3 percent maximum allowable voltage drop and must submit any "as-equal" equipment substitutions to the engineer for approval no later than one week prior to the bid date.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INDEX OF DRAWINGS

B I D D O C U M E N T S

ISSUE DATE:

SEPTEMBER 17, 2025

COVER SHEET

PROJECT LOCATION KEY PLAN

TRUE NORTH

CCADF CLUSTER 1

GENERATOR REPLACEMENT

ELECTRICAL

E0.0 LEGEND AND GENERAL NOTES - ELECTRICAL

E0.1 ONE LINE DIAGRAM AND SCHEDULES

E1.1 ENLARGED PLANS - ELECTRICAL

E2.1 PHOTOS - ELECTRICAL

PRIME CONSULTANT

PROJECT

LOCATION

PROJECT NUMBER: 251780

Texas Registered Firm No. F-7489 1255 West 15th Street, Suite 300 Plano, TX 75075 469.467.0200 Email: mdengca@md-eng.com Project Number: 251780

AutoCAD SHX Text McKINNEY, TX 75071

AutoCAD SHX Text

4300 COMMUNITY AVE

AutoCAD SHX Text

%%UPROJECT LOCATION MAP

AutoCAD SHX Text

%%UVICINITY MAP

AutoCAD SHX Text

HIGHWAY

AutoCAD SHX Text

AutoCAD SHX Text

BLOOMDALE

AutoCAD SHX Text

ROAD

AutoCAD SHX Text

COMMUNITY

AutoCAD SHX Text

AVE

WIRE SIZES ARE INDICATED BY AMERICAN WIRE GAGE OR CIRCULAR MILS.

NOTES BY SYMBOL APPLY TO DRAWING ON WHICH AND WHERE SYMBOL APPEARS.

ALL DIMENSIONS GIVEN SHALL BE INTERPRETED AS DIMENSION

TO THE TOP OF THE ELECTRICAL BOX IN ACCORDANCE WITH ADA.

1. DO NOT COMBINE NEUTRALS AND GROUNDS OF SEPARATE BRANCH

CIRCUITS.

2. WIRE SHALL BE COPPER THWN - SOLID FOR SIZES 12, 10, 8;

STRANDED FOR SIZES 6 AND LARGER.

INDICATES FIXTURE TYPE - SEE LIGHT FIXTURE SCHEDULE

INDICATES PANEL CIRCUITLA-1

LIGHTING FIXTURE

WIRING METHOD NOTES:

ELECTRICAL CONVENTIONS

(ALL CONVENTIONS MAY NOT APPEAR ON DRAWINGS.)

GENERAL NOTES APPLY TO ELECTRICAL DRAWING SET.

DRAWING NOTES APPLY TO DRAWING ON WHICH NOTE APPEARS.

TYPICAL LIGHTING NOTATIONS SHOWN ON LIGHTING PLAN:

CENTER LINE

NUMBER OF POLES

RATING OF SWITCH

RATING OF FUSES OR NON-FUSIBLE

NEMA ENCLOSURE TYPE.

3P/60A/NF/3R

DISCONNECT SWITCH

(ALL SYMBOLS MAY NOT APPEAR ON DRAWINGS.)

DRAWING SYMBOLS

NUMBER

DESCRIPTION

SCALE

DETAIL #

DRAWING NO. TO REFER TO

SECTION NUMBER

DRAWING NUMBER WHERE

SECTION IS LOCATED

SECTION

X X X

X X-X

X X-X

A

DETAIL SYMBOL

SUBTITILE

TYPICAL POWER NOTATIONS SHOWN ON POWER PLAN:

x INDICATES SWITCH ASSOCIATED WITH FIXTURE

LB-3,5 PANELBOARD, SWITCHBOARD OR MOTOR CONTROL

CENTER CIRCUIT DESIGNATION

ELECTRICAL ONE LINE SYMBOLS

(ALL SYMBOLS MAY NOT APPEAR ON DRAWINGS.) (ALL SYMBOLS MAY NOT APPEAR ON DRAWINGS.)

J

MOTORIZED DAMPERS

NON FUSED DISCONNECT SWITCH

FUSED DISCONNECT SWITCH, FUSE RATING INDICATED

208V OR 240V PANELBOARD

480V OR 600V POWER PANELBOARD

PUSH BUTTON

D ELECTRIC DOOR OPENER

TRANSFORMER

CIRCUIT BREAKER

MOTOR SYMBOL; THE NUMBER INSIDE

INDICATES HP.

SECURITY CAMERA

TV

TELEVISION DATA OUTLET; SINGLE GANG 2.5"

DEEP BOX AT 72" AFF, UNLESS NOTED

OTHERWISE, (WITH 1-1/4" CONDUIT TO ABOVE

NEAREST CEILING).

F0

WP

SP

TELECOMMUNICATION OUTLET; 1-GANG BOX AT

18" AFF WITH 1" CONDUIT TO ABOVE NEAREST

ACCESSIBLE CEILING; SUBSCRIPTED NUMBER

INDICATES MOUNTING HEIGHT AFF

DATA SYSTEM FIBER OPTIC JACK; SINGLE GANG

BOX AT 18" AFF WITH 1" CONDUIT TO ABOVE

NEAREST ACCESSIBLE CEILING; SUBSCRIPTED

NUMBER MOUNTING HEIGHT AFF

TELECOMMUNICATION PHONE. VOICE AND DATA

JACK; 1-GANG BOX AT 48" AFF WITH 1" CONDUIT

TO ABOVE NEAREST ACCESSIBLE CEILING;

SUBSCRIPTED NUMBER INDICATES MOUNTING

HEIGHT AFF

OCCUPANCY SENSOR "SWITCH PACK" OR

"POWER PACK" REFER TO DETAIL 8 ON SHEET E3

CONTROLLED DOOR

W

OVERHEAD DOOR CONTROLLER

CLOCK SYSTEM SINGLE RECEPTACLE; NEMA

5-15R AT 80" ABOVE FINISHED FLOOR UNO.

CEILING MOUNTED WIRELESS WIFI ANTENNA

CARD READERCR

AE

INDICATES FIXTURE TYPE - SEE LIGHT FIXTURE SCHEDULE

SAME FIXTURE TYPE WITH EMERGENCY BATTERY BACKUP

FURNITURE VOICE/DATA WHIP

WIRELESS ACCESS POINTWAP

WIRELESS ACCESS POINT, CEILING MOUNTEDWAP

EQUIPMENT CABINET OR PANEL

GROUND BAR

MOTOR SYMBOL, FLOOR PLANS

AUTOMATIC TRANSFER SWITCH

SURGE PROTECTIVE DEVICE

ATS

SPD

T LOW VOLTAGE TRANSFORMER DRAWN TO SCALE

PTS PARTITION SENSOR

TELECOM OUTLETS

ELECTRICAL CONTROLS

(ALL SYMBOLS MAY NOT APPEAR ON DRAWINGS.)

MOTOR STARTER

COMBINATION MOTOR STARTER AND FUSED SAFETY

SWITCH, FUSE RATING INDICATED

MANUAL MOTOR STARTER

EMERGENCY POWER OFF

SM

TOGGLE SWITCH, MOTOR RATED

SMS

MOTORIZED SHADE SWITCH

TC TIME CLOCK

VFD VARIABLE FREQUENCY DRIVE

TELECOMMUNICATION OUTLET, MOUNTED IN FLOOR BOX

TELECOMMUNICATION OUTLET, CEILING MOUNTED

ELECTRICAL EQUIPMENT

(ALL SYMBOLS MAY NOT APPEAR ON DRAWINGS.)

BUS DUCT

BUS DUCT PLUGB

CIRCUITS

(ALL SYMBOLS MAY NOT APPEAR ON DRAWINGS.)

RACEWAY CONCEALED IN CEILING OR WALL. EXPOSED

RACEWAY IS ALLOWED ONLY WHERE NOTED.

RACEWAY BELOW SLAB OR UNDERGROUND

RACEWAY UP

RACEWAY DOWN

RACEWAY CONTINUATION

RACEWAY STUB-OUT WITH CAP

JUNCTION BOX

RECEPTACLES

(ALL SYMBOLS MAY NOT APPEAR ON DRAWINGS.)

CIRCUITS

NORMALEMERGENCY

RECEPTACLES TYPES

(ALL SYMBOLS MAY NOT APPEAR ON DRAWINGS.)

SINGLE RECEPTACLE, 120V; NEMA 5-20R

AT 18" ABOVE FINISHED FLOOR UNO.

SINGLE RECEPTACLE, CEILING MOUNTED

SINGLE RECEPTACLE, FLOOR MOUNTED

DUPLEX RECEPTACLE, 120V; NEMA 5-20R

AT 18" ABOVE FINISHED FLOOR UNO.

SINGLE RECEPTACLE, FLOOR MOUNTED

QUADRAPLEX RECEPTACLE, 120V; NEMA 5-20R

AT 18" ABOVE FINISHED FLOOR UNO.

QUADRAPLEX RECEPTACLE, CEILING MOUNTED

SPLIT WIRED RECEPTACLE, 120V, TOP SWITCHED

RECEPTACLE, NEMA ###

INDICATES CONTROLLEDN/A

MULTI-SERVICE FLOOR BOX

(RECEPTACLES/OUTLETS AS INDICATED)

OUTLET, MOUNTED IN POKE THRU

(RECEPTACLES/OUTLETS AS INDICATED)

OUTLET, MOUNTED ON POWER POLE

(RECEPTACLES/OUTLETS AS INDICATED)

CEILING CORD DROP, 120V

A. THE ELECTRICAL CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS

FROM AUTHORITY HAVING JURISDICTION AND PAY ALL ASSOCIATED FEES.

B. LOCATE JUNCTION AND PULL BOXES AS REQUIRED TO ALLOW ACCESS

AFTER EQUIPMENT AND APPURTENANCES ARE INSTALLED. COORDINATE

LOCATIONS AND ELEVATIONS OF ELECTRICAL DEVICES WITH DRAWINGS

AND OTHER TRADES PRIOR TO INSTALLATION.

C. PROTECT PERMANENT BUILDING FIXTURES FROM DAMAGE DURING

CONSTRUCTION PERIOD. PROVIDE PLYWOOD OR SIMILAR MATERIAL

UNDER EQUIPMENT OR MATERIALS STORED ON FLOORS AND IN AREAS

WHERE CONSTRUCTION MAY DAMAGE FINISHES. SURFACES OR FINISHES

DAMAGED DURING CONSTRUCTION SHALL BE REPLACED AT THE COST OF

THE CONTRACTOR.

D. BRANCH CIRCUITS OVER 75 FEET (25 METERS) IN LENGTH (TOTAL ONE

WAY) FROM THE PANEL, THE ELECTRICAL CONTRACTOR SHALL

CALCULATE THE VOLTAGE DROP AND PROVIDE AN APPROPRIATE

CONDUCTOR SIZE TO ACHIEVE NO MORE THAN 3% MAXIMUM ALLOWABLE

VOLTAGE DROP.

E. DO NOT SCALE THE DRAWINGS. BECAUSE OF THE SCALE OF THE

DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS OR

OTHER SIMILAR ITEMS WHICH MAY BE REQUIRED TO MAKE A COMPLETE

OPERATING SYSTEM. CAREFULLY INVESTIGATE CONDITION AFFECTING

WORK AND INSTALL WORK IN SUCH A MANNER THAT INTERFERENCES

BETWEEN PIPES, CONDUIT, DUCT, EQUIPMENT, ARCHITECTURAL AND

STRUCTURAL FEATURES SHALL BE AVOIDED.

F. PROVIDE 'SEAL-OFFS' WHEN CONDUIT PASSES THROUGH AREAS OF

DIFFERENT AMBIENT TEMPERATURES AND/OR HAZARDOUS AREAS.

G. IF MORE THAN THREE CURRENT-CARRYING CONDUCTORS ARE ROUTED

IN THE SAME CONDUIT, DERATING SHALL BE TAKEN INTO ACCOUNT.

INCREASING THE CONDUCTOR AMPACITY (BY INCREASING WIRE SIZE) TO

COMPENSATE AS FOLLOWS:

NO. OF CONDUCTORS AMPACITY INCREASE

4 THRU 6 125%

7 THRU 9 145%

10 THRU 20 (MAX) 200%

THE CONDUIT SIZE (CAPACITY) SHALL ALSO BE INCREASED TO CONFORM

TO NEC, CHAPTER 9.

H. ALL EQUIPMENT TO BE CONSIDERED 'AS-EQUAL' MUST BE SUBMITTED TO

THE ENGINEER FOR APPROVAL NO LATER THAN ONE (1) WEEK PRIOR TO

BID DATE.

I. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE WITH ALL

TRADES FOR SUBSTITUTED EQUIPMENT FROM THIS DESIGN.

UNCOORDINATED CHANGES THAT OCCUR FROM A SUBSTITUTION WILL BE

THE CONTRACTORS RESPONSIBILITY TO ABSORB THE COST AND NOT

PASS ONTO THE OWNER.

J. PROVIDE PROTECTION IN FIRE RATED WALL MEMBRANE PENETRATIONS.

PROTECTION SHALL WRAP THE OUTSIDE OF THE BOX OR ENCLOSURE TO

MAINTAIN WALL FIRE RATING. DO NOT USE PENETRATION PROTECTION

ON THE INTERIOR OF BOX/ENCLOSURE OR COVER PLATE TYPE

PROTECTION. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

K. LISTED OR LABELED EQUIPMENT SHALL BE INSTALLED AND USED IN

ACCORDANCE WITH ANY INSTRUCTION INCLUDED IN THE LISTING

OR LABELING. (NEC 110.3.B).

GENERAL NOTES

(ALL CONVENTIONS MAY NOT APPEAR ON DRAWINGS.)

M

ZONE DAMPERSZD

MANUAL TRANSFER SWITCHMTS

EPO

TELECOMMUNICATION OUTLET, MOUNTED IN POLE THRU

TELECOMMUNICATION OUTLET, MOUNTED IN POWER POLE

ADA AMERICANS WITH DISABILITIES ACT

ABOVE FINISHED FLOORAFF

ABOVE FINISHED GRADEAFG

AIR HANDLING UNITAHU

AIC

ABOVE FINISHED CEILINGAFC

APPROXIMATE OR APPROXIMATELY

ALTERNATEALT

APPROX

AMERICAN WIRE GAGE

ARCHITECT

AUTOMATIC TRANSFER SWITCH

AUXILIARY

ARCH

ATS

AUX

AWG

BELOW FINISHED CEILINGBFC

BELOW FINISHED GRADEBFG

BUILDINGBLDG

CONDUIT OR TUBINGC

CIRCUIT BREAKERCB

CLOSED-CIRCUIT TELEVISIONCCTV

CIRCUITCKT

CEILINGCLG

COMMUNICATIONSCOMM

DIRECT CURRENTDC

CURRENT TRANSFORMER(S)CT(S)

DISCONNECTDISC

DOUBLE-POLE, DOUBLE THROWDPDT

DOUBLE POLE, SINGLE THROWDPST

DRAWING(S)DWG(S)

EMPTY CONDUIT OR TUBINGEC

EHH ELECTRICAL HANDHOLE

ELEV ELEVATION

EMERG EMERGENCY

EMH ELECTRICAL MANHOLE

EMT ELECTRICAL METALLIC TUBING

FUSE(S)F

FURNISHED BY OWNERFBO

FLOORFL

FULL LOAD AMPERE(S)FLA

FLEXIBLEFLEX

FS

GROUNDG

GROUND FAULT CIRCUIT INTERRUPTGFCI

HIGH INTENSITY DISCHARGEHID

HAND-OFF-AUTOMATICHOA

HORSEPOWERHP

HIGH PRESSURE SODIUMHPS

HVAC

HERTZHZ

INTERMEDIATE METALLIC CONDUITIMC

JBOX JUNCTION BOX

KILOAMPERE(S)KA

KW KILOWATTS(S)

KWH KILOWATT-HOUR(S)

KV KILOVOLT(S)

KVA KILOVOLT-AMPERE(S)

KVAR KILOVOLT-AMPERE(S) REACTIVE

LPS LOW PRESSURE SODIUM

LIGHTINGLTG

METER(S)m

MAXIMUMMAX

MAIN CIRCUIT BREAKERMCB

MOTOR CONTROL CENTERMCC

MOTOR CIRCUIT PROTECTORMCP

METAL HALIDEMH

MANUAL MOTOR STARTERMMS

MANUAL TRANSFER SWITCHMTS

MEGAVOLT-AMPERE(S)MVA

MEGAVOLT-AMPERE(S) REACTIVEMVAR

MW MEGAWATT(S)

NC NORMALLY CLOSED

NATIONAL ELECTRICAL CODENEC

NEMA

NATIONAL FIRE PROTECTIONNFPA

NON-FUSIBLE SAFETY SWITCHNF

NOT IN CONTRACTNIC

NORMALLY OPENNO

NOT TO SCALENTS

PF POWER FACTOR

PL PILOT LIGHT

PNL PANELBOARD

PVC POLYVINYL CHLORIDE

RC REMOTE CONTROL

RCP REFLECTED CEILING PLAN

RCPT RECEPTACLES(S)

RGS RIGID GALVANIZED STEEL

RVSS REDUCED VOLTAGE, SOLID STATE

SF SQUARE FOOT OR FEET

SPDT SINGLE-POLE, DOUBLE-THROW

SPST SINGLE-POLE, SINGLE-THROW

SS START-STOP

SW SWITCH

SWBD SWITCHBOARD

TA TRIP AMPERE(S)

TAS TEXAS ACCESSIBILITY STANDARDS

TYPICALTYP

UG UNDERGROUND

UL UNDERWRITERS LABORATORIES, INC.

UPS UNINTERRUPTIBLE POWER SUPPLY

VARIABLE FREQUENCY DRIVE

VOLT-AMPERE(S)

VFD

VA

V VOLTAGE OR VOLT(S)

W/O W/

WITHOUT

WITH

WP

W

WEATHERPROOF

WATT(S)

XFMR

XP

TRANSFORMER

EXPLOSION-PROOF

DELTA

NUMBER

NIGHT LIGHTNL

AMPERE(S)

ALTERNATING CURRENTAC

A

AMPERE INTERRUPTING

CAPACITY(ROOT MEAN SQUARE

SYMMETRICAL)

NATIONAL ELECTRICAL

MANUFACTURER'S ASSOCIATION

FUSIBLE SAFETY SWITCH OR

FUSIBLE SWITCH

ELECTRICAL ABBREVIATIONS

(ALL ABBREVIATIONS MAY NOT APPEAR ON DRAWINGS.)

MINIMUM CONDUCTOR AMPACITYMCA

MAXIMUM OVER-CURRENTMOCP

HEATING AND AIR CONDITIONINGHACR

HEATING, VENTILATION AND AIR

CONDITIONING

UNO UNLESS NOTED OTHERWISE

E/R EXISTING TO BE REMOVED AND

REINSTALLED AFTER MODIFICATION

RATING

CABLE TELEVISIONCATV

EXISTING

ELECTRICAL WATER COOLER

EX

EWC IES

ISOLATED GROUNDIG

ILLUMINATING ENGINEERING

SOCIETY OF NORTH AMERICA

MICROPHONEMIC

MINIMUMMIN

MAIN LUGS ONLYMLO

MILLIMETER(S)mm

PROTECTION

ASSOCIATION

OVERHEADOH

P POLE(S)

PA PUBLIC ADDRESS SYSTEM

TELEPHONETEL

TEMPORARYTEMP

TEXAS UTILITIES ELECTRICTU

TELEVISIONTV

ALUMINUMAU

COPPERCU

MULTIOUTLET ASSEMBLY

FLOOR-MOUNTED DUPLEX RECEPTACLE

AND DATA CONNECTION.

FURNITURE POWER WHIP

HARDWIRE CONNECTION OR PROVISION FOR

CONNECTION; SEE SPECIAL-PURPOSE

RECEPTACLE, CONNECTION AND FLOOR BOX

SCHEDULED ON DRAWING

SPECIAL-PURPOSE RECEPTACLE; SEE

SPECIAL-PURPOSE RECEPTACLE, CONNECTION

AND FLOOR BOX SCHEDULED ON DRAWING

RECEPTACLE 208 VOLT

B

B

# DUPLEX RECEPTACLE, 120V; NEMA 5-20R AT 18"

ABOVE FINISHED FLOOR UNO.

SEE BELOW FOR LIST OF SUBSCRIPTS FOR #:

AC = MOUNTED ABOVE 3" ABOVE COUNTER

BACKSPLASH

D = DEDICATED CIRCUIT

G = GROUND-FAULT CIRCUIT INTERRUPTER

IG = ISOLATED GROUND RECEPTACLE

S = DETENTION PLATE. CIRCUITS ASSOCIATED

WITH DEVICE SHALL BE CONNECTED TO A

GFCI BREAKER

SU = SURGE PROTECTOR

T = TAMPER PROTECTOR

TV = TV RECEPTACLE

U = INTEGRAL USB PORT(S)

WP = GROUND-FAULT CIRCUIT INTERRUPTER W/

WEATHERPROOF COVERPLATE

n = RECEPTACLE MOUNTED n INCHES ABOVE

FINISHED FLOOR OR GRADE

GENERATOR ANNUNCIATOR PANELGAP

ALL MECHANICAL EQUIPMENT AND INSTALLATIONS SHALL CONFORM WITH THE

REQUIREMENTS OF THE 2023 NATIONAL ELECTRIC CODE, THE 2021 INTERNATIONAL

MECHANICAL CODE, THE 2021 INTERNATIONAL ENERGY CONSERVATION CODE,

THE 2021 INTERNATIONAL BUILDING CODE, STATE AND LOCAL AMENDMENTS,

NATIONAL FIRE PROTECTION ASSOCIATION, UNDERWRITERS LABORATORIES (OR

ETL), AND ALL APPLICABLE LOCAL CODES AND ORDINANCES AND ANY APPLICABLE

OWNER STANDARDS.

PROJECT APPLICABLE CODES

E0.0

LEGEND AND

GENERAL NOTES

- ELECTRICAL

Project No.

251780

Sheet No.

Re vi si o ns

C ol lin C ou nt y A du t D et en tio n

C om m un ity A ve

M cK in ne y, T ex as

Te xa s Re g is te re d F irm N o

F

-7

N o rth

C e nt ra l E xp w y.

Su ite

Pl a no

TX

9.

7.

Em a il:

m d e ng c a m d -e ng .c o m

Pr o je c t N um b e r:

Fa cil ity C lu ste r

G en er at or

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text 09/24/25

AutoCAD SHX Text 09/24/2025

CONSTRUCTION DOCUMENTS

S

E

TS

: 4 #6

K

C M

IL

1# 1/

G

. 4 "C

(E

X

IS

T)

SPACE SPACE SPACE

EXISTING WESTINGHOUSE METAL ENCLOSED, UNIT SUBSTATION "A"

480Y / 277 VOLTS, 3 PHASE, 4 WIRE

LOCATED IN ROOM B1064, BULDING B

EXISTING MAIN DISTRIBUTION PANELBOARD "MDP"

480Y / 277 VOLTS, 3 PHASE, 4 WIRE

800 AMPS MAIN CIRCUIT BREAKER

60800

GND. BUS

3/0 CU

TVSS

G

TVSS

EMERGENCY SYSTEM (EXIST)

4#500 KCMIL, 1#3G, 3.5"C (EXIST.)

EXIST.

ATS-H

400A 4P

4#

K

C M

IL

1#

3G . 3

.5 "C

(E

X

IS

T)

EMERGENCY SYSTEM (EXIST)

4#500 KCMIL, 1#3G, 3.5"C (EXIST.)

EMERGENCY SYSTEM (EXIST)

4#500 KCMIL, 1#3G, 3.5"C (EXIST.)

4# 1/

0, 1#

6G . 2

"C

(E X

IS

T)

EXIST.

ATS-EH

150A

4P EXIST.

ATS-EG

100A 4P

4# 1, 1# 6G

. 2 "C

(E

X

IS

T)

3/0 CU

GND.

BOND NEUTRAL TO GROUND

REPLACE EXISTING DIESEL GENERATOR "G"

500 KW, 480Y/277 VOLTS,

3 PHASE, 4 WIRE

2 SETS: 4#600 KCMIL,

1#1/0 G. 4"C.

EXIST

ELH

EXIST

ELMH

EXIST

HL

EXIST

ELL

EXIST

ELML

EXIST

LL

4# 1, 1# 6G

. 2 "C

(E

X

IS

T)

4# 1, 1# 6G

. 2 "C

(E

X

IS

T)

4#

K

C M

IL

1#

3G . 3

.5 "C

(E

X

IS

T)

4# 1/

0, 1#

6G . 2

"C

(E X

IS

T)

4# 1, 1# 6G

. 2 "C

(E

X

IS

T)

4# 1, 1# 6G

. 2 "C

(E

X

IS

T)

EXIST.

TELL

30 KVA

EXIST.

TELML

30 KVA

EXIST.

TLL

30 KVA

#6 #6 #6

SCOPE OF WORK

REPLACE EXISTING DIESEL GENERATOR WITH NEW DIESEL GENERATOR, AS

SPECIFIED BELOW. INSTALL POWER, CONTROL, AND FUEL CONNECTIONS.

CONTROL CONNECTIONS SHALL INCLUDE START SIGNALS FROM ALL 3

EXISTING ATS'S. FUEL CONNECTIONS SHALL INCLUDE FUEL PIPING FROM

THE ADJACENT EXISTING FUEL TANK, AND CONTROL WIRING TO NEW

SUB-BASE TANK, COMPLETE WITH FUEL LEVEL FLOAT SWITCH TO SIGNAL

"LOW FUEL". TEST UNDER FULL LOAD WITH A TEMPORARY LOAD BANK.

REMOVE EXISTING GENERATOR AND DISPOSE OF THE EXISTING GENERATOR

AS DIRECTED BY OWNER.

PROVIDE A TEMPORARY GENERATOR, COMPLETE WITH CABLES AND THE

REQUIRED FUEL TO PROVIDE STANDBY BY POWER DURING GENERATOR

REPLACEMENT. GENERATOR SHALL START AND RUN DURING

INTERRUPTIONS OF NORMAL POWER.

EXIST.

GENERATOR

DOCKING

STATION

TO REMAIN

EXISTING EMERGENCY DISTRIBUTION

PANELBOARD 480Y / 277 VOLTS, 3 PHASE, 4 WIRE

800 AMPS MAIN LUGS

EQUIPMENT LOCATED WITHIN CLUSTER 1 ELECTRIC ROOM

2 SETS: 4#600 KCMIL,

1#1/0 G. 4"C.

(EXIST)

E0.1

ONE LINE

DIAGRAMS AND

SCHEDULES

Project No.

251780

Sheet No.

Re vi si o ns

C ol lin C ou nt y A du t D et en tio n

C om m un ity A ve

M cK in ne y, T ex as

Te xa s Re g is te re d F irm N

N o rth

C e nt ra l E xp w y.

Su ite

Pl a no

7.

Em e ng c a m d -e ng .c o m

Pr o je c t N um b e r:

Fa cil ity C lu ste r

G en er at or

ONE LINE DIAGRAM - ADF CLUSTER 101 SCALE: NTS

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text 09/24/25

AutoCAD SHX Text 09/24/2025

CLUSTER 1

AIR

COURTYARD

BUILDING EXTENT

1a3

1b

EXISTING

FUEL TANK

DISCHARGE 6

NOTES BY SYMBOL " "

1. THE EXISTING GENERATOR SHALL BE REMOVED AND DISPOSED

OF IN ACCORDANCE WITH THE OWNER'S INSTRUCTIONS. REMOVE

THE FOLLOWING ITEMS FROM THE GENERATOR AND INSTALL

THEM ON THE NEW GENERATOR:

a. POWER AND SIGNAL CABLES TO THE ALTERNATOR, CONTROL

PANEL, POWER TO FUEL PUMP, BATTERY CHARGER AND BLOCK

HEATER.

b. FUEL LINES, FUEL PUMP, FLOAT VALVE, AND VENT STACKS

2. ORIENT NEW GENERATOR ON THE EXISTING GENERATOR PAD AS

SHOWN.

3. LOCATION OF EXISTING GENERATOR DOCKING STATION TO

REMAIN. MAKE POWER AND SIGNAL CONNECTIONS HERE.

4. DEVIATION FROM THE BASIS OF DESIGN WILL REQUIRE THE

CONTRACTOR TO ENLARGE THE GENERATOR PAD TO

ACCOMMODATE THE NEW GENERATOR, AT NO ADDITIONAL COST

TO THE OWNER.

5. CONNECT EXISTING GENERATOR FEEDERS, RETAINED FOR

GENERATOR REMOVAL, TO NEW GENERATOR. REFER TO ONE-

LINE DIAGRAM E0.1.

6. CONNECT EXISTING FUEL TANK FUEL LINES, RETAINED FOR

GENERATOR REMOVAL, TO NEW GENERATOR. REFER TO ONE-

LINE DIAGRAM E0.1.

GENERAL NOTES

A. REFER TO DRAWING E0.0 FOR ELECTRICAL LEGEND,

ABBREVIATIONS AND GENERAL NOTES - ELECTRICAL

B. ELECTRICAL CONTRACTOR SHALL VERIFY WITH

CONSTRUCTION MANAGER, THAT A SURVEY HAS BEEN

CONDUCTED AND ALL UNDERGROUND UTILITIES HAVE BEEN

IDENTIFIED.

C. UTILITIES SHOWN ON THESE DRAWINGS ARE FOR

REFERENCE ONLY. ELECTRICAL CONTRACTOR SHALL

COORDINATE EXACT LOCATION OF ALL EXISTING UTILITIES

AND ROUTING OF ALL NEW UNDERGROUND UTILITIES WITH

RESPECTIVE TRADES (PLUMBING, CIVIL, ETC.), PRIOR TO

DIGGING. MINIMIZE DIGGING BY SHARING TRENCHES

WHENEVER POSSIBLE.

D. COORDINATE SERVICE SHUT-DOWNS WITH ALL TRADES

INVOLVED ON SITE AND OBTAIN WRITTEN AUTHORIZATION

FROM OWNER 72 HOURS PRIOR TO ANY ELECTRICAL WORK.

E1.1

ENLARGED

PLANS -

ELECTRICAL

NORTH

Project No.

251780

Sheet No.

Re vi si o ns

C ol lin C ou nt y A du t D et en tio n

C om m un ity A ve

M cK in ne y, T ex as

Te xa s Re g is te re d F irm N

N o rth

C e nt ra l E xp w y.

Su ite

Pl a no

7.

Em e ng c a m d -e ng .c o m

Pr o je c t N um b e r:

Fa cil ity C lu ste r

G en er at or

ENLARGED PLAN - ADF CLUSTER 101 SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

GRAPHIC SCALE:

AutoCAD SHX Text 1/4"=1'-0"

AutoCAD SHX Text 16'

AutoCAD SHX Text 8'

AutoCAD SHX Text 4'

AutoCAD SHX Text 2'

AutoCAD SHX Text

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text 09/24/25

AutoCAD SHX Text Key Plan

AutoCAD SHX Text Cluster 1 Site

AutoCAD SHX Text 09/24/2025

E2.1

PHOTOS -

ELECTRICAL

Project No.

251780

Sheet No.

Re vi si o ns

C ol lin C ou nt y A du t D et en tio n

C om m un ity A ve

M cK in ne y, T ex as

Te xa s Re g is te re d F irm N

N o rth

C e nt ra l E xp w y.

Su ite

Pl a no

7.

Em e ng c a m d -e ng .c o m

Pr o je c t N um b e r:

Fa cil ity C lu ste r

G en er at or

CLUSTER 1 - PHOTOS01 SCALE: NTS

EXISTING GENERATOR AND DOCKING STATION EXISTING GENERATOR ELECTRICAL EXISTING GENERATOR OVERVIEW EXISTING GENERATOR CONTROLS

EXISTING GENERATOR FUEL CONNECTIONS EXISTING GENERATOR CONTROL PANEL EXISTING GENERATOR FUEL CONNECTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text 09/24/25

AutoCAD SHX Text Key Plan

AutoCAD SHX Text Cluster 1 Site

AutoCAD SHX Text 09/24/2025

251780 - COVER
251780 - COVER
251780 - E0.0
251780 - E0.0
251780 - E0.1
251780 - E0.1
251780 - E1.1
251780 - E1.1
251780 - E2.1
251780 - E2.1

File details come from the government source that posted it. Updated .