250917 LPS CO Monument Sign Add 1 Revised Drawings (25-041).pdf
PDF 4 MB Posted
- Attached to
- LPS Central Office Complex Monument Sign Bid
- Solicitation number
- RFP-LPS-250000003111-2
- Issued by
- Wayne County, Michigan
About this file
The document is a set of architectural and electrical design plans for the Livonia Public Schools Central Office Complex Monument Sign project located in Livonia, Michigan. The project involves the complete removal of an existing monument sign and electrical infrastructure, followed by the installation of a new monument sign with specific design details. The plans, dated September 10, 2025 with an addendum on September 17, 2025, outline comprehensive site demolition, new work site plans, electrical site plans, and detailed construction specifications. The project includes removing the existing sign, concrete sidewalk, mulch, and plants, and then reinstalling salvaged concrete pavers and installing a new concrete sidewalk with control joints.
The new monument sign will feature a brick veneer base with cast stone caps in two colors (limestone and blue stain), dimensional blue letters, and an embossed district logo on both sides. The electrical design includes a new junction box, ground-mounted lights for the monument sign and flag pole, and integration with the existing electrical panel LP-A2. The base bid specifies a stone sign in white, with an alternate option for an EPS foamcore sign sprayed with a poly armor hard coat. Color specifications include Sherwin Williams Dignity Blue for the dimensional letters and Elgin Butler Cobalt Blue for the glazed brick, with the brick veneer to match the existing site conditions.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REMOVE AND SALVAGE
CONCRETE PAVERS
REINSTALL SALVAGED
CONCRETE PAVERS AFTER
CONSTRUCTION TO MATCH
ORIGINAL DESIGN
INSTALL NEW MULCH
REMOVE EXISTING MULCH
AND PLANTS
REMOVE EXISTING
CONCRETE SIDEWALK
INSTALL NEW CONCRETE
SIDEWALK. ADD CONCRETE
CONTROL JOINTS ( SIMILAR
TO EXISTING) - REFER TO
B/A1.00
EXISTING FLAG POLE TO
REMAIN
REMOVE EXISTING
MONUMENT SIGN
INCLUDING BASE AND
FOUNDATION, REMOVE
ELECTRICAL JUNCTION
BOX AND LIGHT. REFER
TO ELECTRICAL10'-0"
3'-0"
8'-5"
10"
+/-R10'-0"
Ø15'-0"
R10'-0"
REMOVE AND SALVAGE
CONCRETE PAVERS
REMOVE EXISTING MULCH
AND PLANTS
REMOVE EXISTING
CONCRETE SIDEWALK
EXISTING FLAG POLE TO
REMAIN
REMOVE EXISTING
MONUMENT SIGN
INCLUDING BASE AND
FOUNDATION, REMOVE
ELECTRICAL JUNCTION
BOX AND LIGHT. REFER
TO ELECTRICAL
INSTALL NEW MONUMENT
SIGN - REFER TO A1.01
-2
'-6
LIGHTING FIXTURES.
REFER TO ELECTRICAL
FOR COORDINATION.
-2
'-6
RESTORE ALL NON-PAVED AREAS WITH 3" OF CLEAN TOPSOIL AND SEED
MIX (30% KENTUCKY BLUEGRASS, 20% PERENNIAL RYE GRASS, 50%
CREEPING RED FESCUE). PLACE MULCH IN ALL SEEDED AREAS ON
SLOPES IN EXCESS OF 10 HORIZONTAL TO 1 VERTICAL PLACE NORTH
AMERICAN GREEN DS150 MULCH BLANKET IMMEDIATELY AFTER
SEEDING. USE METAL STAPLES PER MANUFACTURERS
RECOMMENDATIONS TO HOLD MATTING IN PLACE
1. EARTHWORK AND PAVEMENT CONSTRUCTION SHALL BE
PERFORMED IN ACCORDANCE WITH THE CURRENT MDOT
STANDARD SPECIFICATIONS FOR CONSTRUCTION
2. REMOVE ANY EXISTING TOPSOIL, VEGETATION, TREES AND OTHER
DELETERIOUS MATERIALS TO EXPOSE TO THE SUBGRADE SOIL.
TREE ROOTS SHALL BE COMPLETELY REMOVED.
3. EXCAVATE TO THE DEPTH OF THE FINAL SUBGRADE ELEVATION TO
ALLOW FOR GRADE CHANGES AND THE PLACEMENT OF THE
RECOMMENDED PAVEMENT SYSTEM.
4. THE TOP 12" OF THE EXPOSED SUBGRADE SHALL BE COMPACTED
TO A DENSITY NOT LESS THAN 95% OF THE MAXIMUM DENSITY AS
DETERMINED BY THE MODIFIED PROCTOR (ASTM D 1557-91)
5. THE FINAL SUBGRADE SHALL BE THOROUGHLY PROOF ROLLED
UNDER THE OBSERVATION OF A GEOTECHNICAL/PAVEMENT
ENGINEER. LOOSE OR YIELDING AREAS WHICH CANNOT BE
MECHANICALLY STABILIZED SHALL BE REMOVED AND REPLACED
WITH ENGINEERED FILL OR AS INDICATED BY FIELD CONDITIONS,
6. THE AGGREGATE BASE SHALL BE COMPACTED TO A DENSITY NOT
LESS THAN 95% OF THE MAX. DENSITY AS DETERMINED BY THE
MODIFIED PROCTOR (ASTM D 1557-91). THE BASE SHALL EXTEND A
MIN. OF 1 FOOT BEYOND THE PAVED BASE.
7. PLACE EXPANSION JOINTS WHERE NEW CONCRETE PAVEMENT OR
WALKS ABUT BUILDING WALLS, CURB, OR EXISTING CONCRETE
PAVEMENT. PLACE JOINT SEALANT ON ALL EXPANSION JOINTS.
8. CONTRACTOR TO CONSTRUCT CONTRACTION AND EXPANSION
JOINTS IN ALL NEW CONCRETE PAVEMENT. CONTRACTION JOINTS
SHALL BE TOOLED WHERE SIDEWALKS WIDTH IS 8' OR LESS, AND
SHALL BE SPACED EQUAL TO THE WIDTH OF THE PAVEMENT, BUT
NOT MORE THAN 10' APART. PLACE EXPANSION JOINTS WITH JOINT
SEALANT AT MAX. 50" SPACING. CONTRACTOR SHALL GENERALLY
MATCH THE JOINT PATTERNS FOR CONCRETE PAVEMENT WHEN
SHOWN ON THE PLANS.
9. CONCRETE PAVEMENT SHALL MEET THE REQUIREMENTS FOR MDOT
GRADE P1 CONCRETE PER THE CURRENT MDOT STANDARD
SPECIFICATIONS FOR CONSTRUCTION.
PAVING CONSTRUCTION NOTES
RESTORATION NOTE
EXISTING CONCRETE
SIDEWALK CONTROL
JOINTS
09/17/2025 ADD 01
DEMOLITION AND
NEW WORK SITE
PLANS
A1.00
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
GRS
AMN
DCJ
KEY PLAN
09/10/2025 BIDS
Livonia Public Schools Central Office Complex Monument Sign
Livonia, Michigan
2025-041
-0
L
PS
-C
EN
TR
AL
O
FF
IC
E
CO
MP
LE
X
MO
NU
ME
NT
S
IG
N
SCALE:
NEW WORK SITE PLAN
1/2" = 1'-0"
SCALE:
DEMOLITION SITE PLAN
1/2" = 1'-0"
A A1.00
SCALE:
EXISTING SIGN
N.T.S A
A1.00
A1.01
E
G A1.01
F A1.01
SCALE:
EXISTING SIGN
N.T.S B
A1.00
ADD
ADD
09/17/2025 ADDENDUM #1
A1.00 A
A1.01 E
CAST STONE CAP COLOR A
(LIMESTONE)
GRADE LINE
EL. 100'-0"
T.O. MASONRY
EL. 102'-0"
SCALE:
ELEVATION
3/4" = 1'-0" F
B
7'- 0"
2'- 0"
CAST STONE CAP COLOR B (BLUE
STAIN)
3'- 0 1
/2" 1'-
0"
BASE BID : STONE SIGN (WHITE)
A1 ALTERNATE : EPS
FOAMCORE SPRAYED WITH
POLY ARMOR HARD COAT
5 1 /4"
5 1 /4"
3 1 /2"
DUAL SIDED
EMBOSSED CUSTOM DISTRICT
LOGO (BOTH SIDES)
2'- 0 1
/4"
1"
4"
BRICK VENEER (BR-1)
4 3 /8"
3 5 /8"
2" 2"
2"
1"
TYP.
1"
1" DEEP EXTENDED LETTERS
FROM FACE OF SIGN (BLUE)
DIMENSIONAL LETTERS (BLUE
TO MATCH BR-2)
GLAZED BLUE BRICK (BR-2)
A1.01 H
8'-7 1/2"
CAST STONE CURVED TOP (BLUE
STAIN)
1 5 /8"
JUNCTION BOX. REFER TO
ELECTRICAL FOR COORDINATION.
5 1 /4"
2"
TYP.
1"
TYP.
SECTION
E
A1.01
3'-0"
3'- 6"
M
IN
IM
UM
J
REINFORCED CONCRETE
FOOTING
(3) #5 BARS TOP & BOTTOM
STONE SIGN
ATTACHMENT REQUIREMENTS
PER SIGN MANUFACTURER
2'- 0"
STONE CURVED TOP (BLUE
STAIN)
PLAN SECTION
A
PLAN SECTION
B
10'-4"
1'-
10'-5 1/2"
2'- 2"
1'-
2"
2"
CAST STONE TOP-
COLOR A (LIMESTONE)
LINE OF BRICK
WALL BELOW
10'-9 1/2"
1"1"
BRICK VENEER (BR-1)
12" CMU
#5 AT 24" O.C.
TOP VIEW
C
STONE TOP-
COLOR B (BLUE STAIN)
8'-3" 2'-2"
2'- 2"
1'- 0"
SLOPED CAST STONE TOP-
COLOR A (LIMESTONE) MIN. 12"
WASH
1'-10"
JUNCTION BOX. REFER TO
ELECTRICAL FOR
COORDINATION.
JUNCTION BOX. REFER TO
ELECTRICAL FOR
COORDINATION.
JUNCTION BOX. REFER TO
ELECTRICAL FOR
COORDINATION.
LINE OF SIGN BELOW
SECTION DETAIL
1" = 1'-0"
CAVITY WALL DRAINAGE SYSTEM
LAMINATED SHEET FLASHING
OPEN HEAD WEEP JOINT
DAMPPROOFING - EXTEND 4" BELOW
BRICK LEDGE
GROUT CAVITY SOLID
GROUT SOLID BELOW FLASHING
BRICK VENEER (BR-1) ON CMU BACK UP
W/ BRICK TIES
ADHESIVE-SET MEMBRANE FLASHING
CAST STONE CAP (COLOR A)
3/8" DIA STAINLESS STEEL ROD TIES (2)
PER PIECE OF CAP GROUT INTO CAP &
WALL. PROVIDE SEALANT AT FLASHING
PENETRATIONS
BACKER ROD AND SEALANT, TYP.
#5 AT 24" O.C. DOWEL. EXTEND
FULL HEIGHT, GROUT
REINFORCED CORE SOLID
DRIP EDGE
2'-0"
2"
4 5/8"1" 1 1/2" 11 5/8" 4 5/8" 1"1 1/2"
4"
DESIGN PERSPECTIVE FOR REFERENCE
N.T.S.
D
H
3' 6"
M
IN
IM
UM
2'- 0"
REINFORCED CONCRETE
FOOTING
(3) #5 BARS TOP & BOTTOM
4x4 GALV. TUBE STEEL FOR
SIGN SUPPORT BY SIGN
CONTRACTOR
J A1.01
BOND BEAM W/
2 - #5 CONTINUOUS
HORIZONTAL JOINT
REINFORCING AT 16"
O.C. VERTICALLY
#5 VERTICAL AT EACH
CORNER
SEALANT & BACKER ROD
EACH SIDE
BRICK VENEER ON 6" CMU,
SOLID GROUT CAVITY
SPACE FOR COMPOSITE
MASONRY WALL
ADHESIVE- SET
MEMBRANE FLASHING
A1 ALTERNATE
G
3'-0"
3'- 6"
M
IN
IM
UM
REINFORCED CONCRETE
FOOTING
(3) #5 BARS TOP & BOTTOM
EPS FOAMCORE SPRAYED
WITH POLY ARMOR HARD COAT
ATTACHMENT REQUIREMENTS
PER SIGN MANUFACTURER
(WHITE FINISH)
2'- 0"
EPS FOAMCORE SPRAYED
WITH POLY ARMOR HARD COAT
CURVED TOP (BLUE)
MONUMENT COLOR FINISH SCHEDULE
ITEM COLOR#
1. SHERWIN WILLIAMS SW 6804 DIGNITY BLUE
2.
DIMENSIONAL LETTERS
3.
GLAZED BRICK ELGIN BUTLER #2200A COBALT BLUE
BRICK VENEER BELDEN BRICK - GARDEN BLEND (VERIFY - TO MATCH EXISTING)
KEY PLAN
09/17/2025 ADD 01
SITE DETAILS
A1.01
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
GRS
AMN
DCJ
KEY PLAN
09/10/2025 BIDS
Livonia Public Schools Central Office Complex Monument Sign
Livonia, Michigan
2025-041
-0
L
PS
-C
EN
TR
AL
O
FF
IC
E
CO
MP
LE
X
MO
NU
ME
NT
S
IG
N
D, E A1.01
D, E A1.01
ADD
ADD
ADD
ADD
ADD
ADD
ADD
ADD
ADD
S2.00
1SECTION
S2.00
2WALL REINFORCING DETAIL
TYPICAL
S2.00
MASONRY CONSTRUCTION DETAIL
S2.00
REINFORCED
G E N E R A L N O T E S
GENERAL CONDITIONS
1. IF ANY GENERAL NOTE CONFLICTS WITH ANY DETAIL OR NOTE ON THE PLANS
OR IN THE SPECIFICATIONS, THE STRICTEST PROVISION SHALL GOVERN.
2. THE STRUCTURAL DRAWINGS ARE FOR THE PLACEMENT AND SIZE OF STRUCTURAL
COMPONENTS ONLY. O.S.H.A., LOCAL GOVERNMENT CODES AND SAFETY CODE
REQUIREMENTS SHALL BE ADHERED TO BY THE CONTRACTOR.
3. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER IT IS
FULLY COMPLETED. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO
DETERMINE ERECTION PROCEDURE AND SEQUENCE, AND TO ENSURE THE SAFETY
OF THE STRUCTURE AND ITS COMPONENT PARTS DURING ERECTION. THIS
INCLUDES PROVIDING TEMPORARY BRACING, SHORING, GUYS OR TIE- DOWNS.
THESE TEMPORARY SUPPORTS WILL REMAIN IN PLACE UNTIL ALL STRUCTURAL
COMPONENTS ARE IN PLACE AND COMPLETED.
4. USE OF ENGINEERING DRAWINGS AS ERECTION DRAWINGS BY THE CONTRACTOR
IS STRICTLY PROHIBITED. DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS
ARE FOR REFERENCE ONLY AND SHOULD NOT BE USED FOR BUILDING LAYOUT AND
LOCATION. SEE ARCHITECTURAL DRAWINGS AND SITE PLAN FOR THESE PURPOSES.
5. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AT THE RATE OF NO MORE
THAN 80 DRAWINGS PER WEEK. THE CONTRACTOR SHALL SUBMIT A SCHEDULE OF
SHOP DRAWINGS PRIOR TO SUBMITTAL. THE CONTRACTOR SHALL CHECK SHOP
DRAWINGS PRIOR TO SUBMITTAL AND IS SOLELY RESPONSIBLE FOR ERRORS &
OMISSION IN THE PREPARATION OF SHOP DRAWINGS TO CONFORM TO THE DESIGN
DRAWINGS. SUBMIT ELECTRONIC SHOP DRAWINGS FOR ENGINEER REVIEW.
6. IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL RELEVANT DIMENSIONS
AND ELEVATIONS FOR EQUIPMENT INSTALLATIONS AGAINST PURCHASED
MANUFACTURER'S CERTIFIED EQUIPMENT DRAWINGS. DIMENSIONS THAT DEPEND
UPON SPECIFIC EQUIPMENT SUCH AS ELEVATOR OPENINGS, MECHANICAL
EQUIPMENT SUPPORTS, ETC. SHALL BE COORDINATED BY THE CONTRACTOR PRIOR
TO SUBMITTAL TO THE ARCHITECT/ENGINEER. SUCH DIMENSIONS SHALL BE
PROVIDED ON THE SHOP DRAWINGS BY THE CONTRACTOR PRIOR TO SUBMITTAL TO
THE ARCHITECT/ENGINEER.
EXISTING CONDITIONS
1. VERIFY ALL EXISTING ASSUMED DIMENSIONS AND CONDITIONS (I.E. EXISTING
MATERIALS; FRAMING MEMBER SIZES AND LOCATIONS; METHODS OF
CONSTRUCTION; ETC.) AT THE SITE PRIOR TO CONSTRUCTION AND FABRICATION.
IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE PROCEEDING WITH
WORK.
FOUNDATIONS
1. FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED SOIL WITH AN ASSUMED SAFE BEARING
CAPACITY OF 2000 P.S.F. IF SOIL OF THIS CAPACITY IS NOT FOUND AT THE
ELEVATIONS INDICATED, FOOTINGS SHALL BE ENLARGED OR LOWERED AT THE
DIRECTION OF THE ARCHITECT. VERIFY FOUNDATION SOIL BEARING PRESSURE IN
FIELD BY SOILS ENGINEER.
2. PROVIDE NECESSARY SHEETING SHORING BRACING, ETC. AS REQUIRED DURING
EXCAVATIONS TO PROTECT SIDES OF EXCAVATIONS.
3. COMPLY FULLY WITH REQUIREMENTS OF OSHA AND OTHER REGULATORY
AGENCIES FOR SAFETY PROVISIONS.
CONCRETE
1. MINIMUM CONCRETE STRENGTH TO BE 3000 P.S.I. @ 28 DAYS, U.O.N.;
SLABS SHALL BE 3500 P.S.I. MIN. U.O.N. EXPOSED CONCRETE SHALL BE 4000 PSI
WITH 6% + 1% ENTRAINED AIR U.O.N.
3. ALL CONCRETE WORK AND PLACEMENT SHALL CONFORM TO THE LATEST
RECOMMENDATIONS OF A.C.I.
4. ALL REINFORCING BARS, DOWELS AND TIES SHALL CONFORM TO A.S.T.M. A615
GRADE 60. REINFORCING STEEL SHALL BE CONTINUOUS AND SHALL HAVE
MINIMUM 36 BAR DIAMETER LAP AND BE FABRICATED AND PLACED IN
ACCORDANCE WITH A.C.I. - 315 LATEST EDITION.
5. REINFORCED CONCRETE WALL FOOTINGS SHALL HAVE CORNER BARS
AT ALL INTERSECTIONS OF THE SAME SIZE AND SPACING AS THE MAIN
HORIZONTAL REINFORCING.
6. CONCRETE CONTRACTOR SHALL INCLUDE IN HIS COST ADDITIONAL CONCRETE
QUANTITY AS REQUIRED TO COMPENSATE FOR DEFLECTIONS OF METAL DECK AND
UNSHORED COMPOSITE BEAMS AND TO PROVIDE A LEVEL CONCRETE SURFACE.
7. FIELD AND SHOP TESTING OF CONCRETE WORK SHALL INCLUDE INSPECTION OF
REINFORCING STEEL PLACEMENT, REBARS, NUMBER, LOCATION, AND LAP SPLICE
LENGTH.
8. PROVIDE DOWELS INTO FOUNDATION TO MATCH SIZE AND SPACING OF VERTICAL
REINFORCEMENT AT ALL COLUMNS AND WALLS, UNLESS OTHERWISE NOTED.
MASONRY
9. UNLESS OTHERWISE SHOWN, PROVIDE THE FOLLOWING COVER FOR
REINFORCING STEEL:
A. UNFORMED SURFACES IN CONTACT WITH EARTH -3 IN.
B. UNFORMED SURFACES OVER MOISTURE BARRIERS -2 IN.
C. FORMED SURFACES EXPOSED TO EARTH OR WEATHER
OR WATER PROOFING/DAMP PROOFING
#6 OR LARGER -2 IN.
#5 OR SMALLER -1 1/2 IN.
D. FORMED SURFACES NOT EXPOSED TO EARTH
OR WEATHER
SLABS AND WALLS -3/4 IN.
COLUMNS -1 1/2 IN.
BEAMS AND GIRDERS -1 1/2 IN.
1. THE MASONRY PORTIONS OF THIS STRUCTURE ARE DESIGNED ACCORDING TO THE
LATEST ALLOWABLE STRESS DESIGN PROVISIONS OF THE MASONRY STANDARDS JOINT
COMMITTEE (MSJC) BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES
(ACI 530/ASCE 602) INCLUDING SECTIONS 2106 AND 2107 OF CHAPTER 21 IN THE
MICHIGAN BUILDING CODE. MASONRY COMPONENTS HAVE BEEN
DESIGNED ACCORDING TO THE PROVISIONS FOR SEISMIC DESIGN CATEGORY B.
2. ALL STRUCTURAL MASONRY IS TO BE CONSTRUCTED IN ACCORDANCE WITH THE
LATEST MASONRY STANDARDS JOINT COMMITTEE (MSJC) BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES (TMS 402/ACI 530/ASCE 5) AND
SPECIFICATIONS FOR MASONRY STRUCTURES (TMS 602/ACI 530.1/ASCE 6)
MASONRY SUBMITTALS ARE REQUIRED BY ACI 530.1/ASCE 6/TMS 602. SECTION 1.5
MASONRY TESTING AND INSPECTIONS ARE REQUIRED BY ACI 530.1/ASCE 6/TMS 602
SECTION 1.6, TABLE 5.
3. ALL STRUCTURAL MASONRY HAS BEEN ENGINEERED IN ACCORDANCE WITH
CHAPTER 2 ALLOWABLE STRENGTH DESIGN. COMPRESSION STRENGTH SHALL BE
DETERMINED ACCORDING TO THE UNIT STRENGTH METHOD FOR CONCRETE
MASONRY MSJC SECTION 1.4. B.2.b.
4. ALL BLOCK SHALL CONFORM TO ASTM C90, TYPE I, WITH A MINIMUM UNIT NET
AREA COMPRESSIVE STRENGTH OF 2000 PSI.
5. MASONRY COMPRESSIVE STRENGTH f'm = 2000 PSI MINIMUM.
6. MORTAR SHALL BE TYPE "S" (1800 PSI) CONFORMING TO ASTM C-270.
USE MORTAR CEMENT WHERE EXTERIOR WALLS ARE UNREINFORCED.
7. PROVIDE HORIZONTAL WIRE TYPE REINFORCING WITH 9 GAUGE SIDE AND CROSS
MEMBERS IN EVERY SECOND COURSE (16" O.C.), IN ALL MASONRY WALLS. WALLS
WITH VERTICAL REINFORCING SHALL ONLY HAVE "LADDER" TYPE REINFORCING.
8. ALL REINFORCING BARS, DOWELS AND TIES SHALL CONFORM TO A.S.T.M. A615
GRADE 60. REINFORCING STEEL SHALL BE CONTINUOUS, FABRICATED AND
PLACED IN ACCORDANCE WITH A.C.I. - 315 LATEST EDITION AND HAVE THE
FOLLOWING MINIMUM LAP LENGTHS:
BAR SIZE 8" CMU 12" CMU
#3 18" 18" #4 24" 24" #5 30" 30" #6 38" 36" #7 42"
#8 PROVIDE MECH. SPLICE
9. ALL MASONRY BELOW GRADE SHALL BE GROUTED SOLID.
10. MASONRY GROUT SHALL CONFORM TO ASTM C 476, WITH PEA GRAVEL
AGGREGATE AND A MINIMUM STRENGTH OF 2000 PSI, BUT NOT LESS THAN
SPECIFIED f'm.
11. PROVIDE DOWELS INTO FOUNDATION TO MATCH SIZE AND SPACING OF VERTICAL
REINFORCEMENT AT ALL COLUMNS AND WALLS, UNLESS OTHERWISE NOTED.
2. FLYASH OR GROUND GRANULATED BLAST FURNACE SLAG MAY BE SUBSTITUTED UP TO
25% MAXIMUM OF MIX DESIGN CEMENT CONTENT IN NON-EXPOSED CONCRETE MIXES.
DO NOT USE IN EXPOSED MIX DESIGNS.
SPECIAL INSPECTION
INSPECTION OF FABRICATOR'S (SEC. 1704.2.5) *
FABRICATION AND IMPLEMENTATION PROCEDURES 1704.2.5.1
*SPECIAL INSPECTION IS NOT REQUIRED FOR FABRICATOR SHOP IF CERTIFICATE
OF APPROVAL SUBMITTED BY FABRICATOR'S INSPECTION AGENCY PER
EXCEPTION 1704.2.5.1
1. WORK CONSTRUCTED SHALL BE INSPECTED BY AN INDEPENDENT TESTING
AGENCY TO ENSURE COMPLIANCE WITH THE REQUIREMENTS SHOWN ON THE
DRAWINGS. INSPECTIONS REQUIRED BY CHAPTER 17 OF THE MICHIGAN
BUILDING CODE; LOCAL BUILDING DEPARTMENTS AND THE CONTRACT
DOCUMENTS SHALL BE PERFORMED BY AN INDEPENDENT TESTING AGENCY. SITE
VISITS BY THE DESIGN ENGINEER DO NOT CONSTITUTE OR REPLACE INSPECTION
2. THE FOLLOWING ITEMS SHALL BE INSPECTED IN ACCORDANCE WITH MBC 2021 SEC.
1704 & 1705 BY A CERTIFIED SPECIAL INSPECTOR UNLESS NOTED OTHERWISE IN
REMARKS COLUMN. ALL INSPECTION SHALL BE CONTINUOUS UNLESS
OTHERWISE NOTED. ALL PRODUCTS WITH ICC APPROVALS SHALL BE INSTALLED
PER THE APPROVAL AND PER MANUFACTURER'S RECOMMENDATIONS. FOR
MATERIAL TESTING REQUIREMENTS, SEE SPECIFICATIONS AND/OR GENERAL
NOTES. TESTING AGENCY SHALL SEND COPIES OF ALL STRUCTURAL TESTING AND
INSPECTION REPORTS DIRECTLY TO THE ARCHITECT.
A. PROVIDE 3000 P.S.I. 28-DAY COMPRESSIVE STRENGTH; W/C RATIO, 0.58
MAXIMUM (NON-AIR-ENTRAINED), 5.0 BAG CEMENT MIX FOR ALL FOUNDATION
WORK UNLESS NOTED OTHERWISE.
B. PROVIDE 3500 P.S.I. 28-DAY COMPRESSIVE STRENGTH; W/C RATIO, 0.53
MAXIMUM (NON-AIR-ENTRAINED), 5.5 BAG CEMENT MIX FOR ALL INTERIOR
SLABS UNLESS NOTED OTHERWISE.
C. PROVIDE 4000 P.S.I. 28-DAY COMPRESSIVE STRENGTH; W/C RATIO, 0.45
MAXIMUM (AIR-ENTRAINED), 6.0 BAG CEMENT MIX FOR ALL EXTERIOR
CONCRETE UNLESS NOTED OTHERWISE.
7. PRE-MANUFACTURED ITEMS SUCH AS CANOPIES, AWNINGS, SUNSHADES, ETC.
SHALL BE DESIGNED BY SUPPLIER. SUPPLIER SHALL SUBMIT SIGNED AND SEALED
OF MICHIGAN FOR RECORD TO ARCHITECT. SHOP DRAWINGS SHALL INDICATE ALL
DESIGN LOADS AND INCLUDE ALL CONNECTIONS AND MATERIAL NECESSARY FOR
INSTALLATION OF PRE-MANUFACTURED ITEMS.
SHOP DRAWINGS AND CALCULATIONS BY A REGISTERED ENGINEER IN THE STATE
VERIFICATION AND INSPECTION TASK CONTINUOUS SPECIAL INSPECTION
1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE
ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY.
2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH
AND HAVE REACHED PROPER MATERIAL.
3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED
FILL MATERIALS.
4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT
THICKNESSES DURING PLACEMENT AND COMPACTION OF
X
X
TABLE 1705.6
REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS
COMPACTED FILL.
5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE
AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY.
X
X
X
NOT
APPLICABLE
MINIMUM TESTS
VERIFICATION OF SLUMP FLOW AND VISUAL STABILITY INDEX (VSI) AS DELIVERED
TO THE PROJECT SITE IN ACCORDANCE WITH SPECIFICATION ARTICLE 1.5 B.1.b.3
FOR SELF-CONSOLIDATING GROUT
VERIFICATION OF f' AND f' IN ACCORDANCE WITH SPECIFICATION ARTICLE 1.4B
PRIOR TO CONSTRUCTION, EXCEPT WHERE SPECIFICALLY EXEMPTED BY THIS CODE
ACCm
MINIMUM INSPECTION
CONTINUOUS PERIODIC
INSPECTION TASK
FREQUENCY (a) REFERENCE FOR CRITERIA
NOT
APPLICABLE
TMS 402/ACI
530/ASCE 5
TMS 602/ACI
530.1/ASCE 6
1. VERIFY COMPLIANCE WITH THE APPROVED SUBMITTALS
2. AS MASONRY CONCSTRUCTION BEGINS, VERIFY THAT THE
FOLLOWING ARE IN COMPLIANCE:
a. PROPORTIONS OF SITE-PREPARED MORTAR.
b. CONSTRUCTION OF MORTAR JOINTS.
c. GRADE AND SIZE OF PRESTRESSING TENDONS AND
ANCHORAGES.
d. LOCATION OF REINFORCEMENT, CONNECTORS, PRESTRESSING TENDONS AND ANCHORAGES.
e. PRESTRESSING TECHNIQUE.
f. PROPERTIES OF THIN-BED MORTAR FOR AAC MASONRY
X ART. 1.5
X ART. 2.1, 2.6A
X ART. 3.3B
X
ART. 2.4B,
2.4H
X
ART. 3.4,
3.6A
X ART. 3.6B
X(b) X(c) ART. 2.1C
3. PRIOR TO GROUTING, VERIFY THAT THE FOLLOWING ARE IN
COMPLIANCE:
a. GROUT SPACE
b. GRADE, TYPE AND SIZE OF REINFORCEMENT AND ANCHOR
BOLTS, AND PRESTRESSING TENDONS AND ANCHORAGES
d. PROPORTIONS OF SITE-PREPARED GROUT AND PRESTRESSING
GROUT FOR BONDED TENDONS.
X
ART. 3.2D,
3.2F
X ART. 2.4, 3.4
c. PLACEMENT OF REINFORCEMENT, CONNECTORS, AND
PRESTRESSING TENDONS AND ANCHORAGES
X
ART. 3.2E,
3.4, 3.6A
e. CONSTRUCTION OF MORTAR JOINTS. X ART. 3.3B
4. VERIFY DURING CONSTRUCTION:
a. SIZE AND LOCATION OF STRUCTURAL ELEMENTS
b. TYPE, SIZE, AND LOCATION OF ANCHORS, INCLUDING
OTHER DETAILS OF ANCHORAGE OF MASONRY TO STRUCTURAL
MEMBERS, FRAMES, OR OTHER CONSTRUCTION
c. WELDING OF REINFORCEMENT
SEC. 2.1.7.7.2,
3.3.3.4(c), 8.3.3.4(b), X
d. PREPARATION, CONSTRUCTION, AND PROTECTION OF
MASONRY DURING COLD WEATHER (TEMPERATURE BELOW
40°F (4.4°C) OR HOT WEATHER (TEMPERATURE ABOVE
90°F (32.2°C)
e. APPLICATION AND MEASUREMENT OF PRESTRESSING FORCE
X
ART. 1.8C,
1.8D
X ART. 3.6B
f. PLACEMENT OF GROUT AND PRESTRESSING GROUT FOR
BONDED TENDONS IS IN COMPLIANCE
X ART. 3.5, 3.6C
g. PLACEMENT OF AAC MASONRY UNITS AND CONSTRUCTION
OF THIN-BED MORTAR JOINTS
X ART. 3.3 B.8(b) X(c)
5. OBSERVE PREPARATION OF GROUT SPECIMENS, MORTAR
SPECIMENS, AND/OR PRISMS
ART. 1.4 B.2.a.3,
1.4 B.2.b.3,
1.4 B.2.c.3,
1.4 B.3, 1.4 B.4
X
(a). FREQUENCY REFERS TO THE FREQUENCY OF INSPECTION, WHICH MAY BE CONTINUOUS DURING THE TASK LISTED
OR PERIODICALLY DURING THE LISTED TASK, AS DEFINED IN THE TABLE.
(b). REQUIRED FOR THE FIRST 5000 SQUARE FEET (465 SQUARE METERS) OF ACC MASONRY.
(c). REQUIRED AFTER THE FIRST 5000 SQUARE FEET (465 SQUARE METERS) OF ACC MASONRY.
X ART. 3.3F
X
SEC. 1.16.4.3,
1.17.1
AND INSPECTION OF MASONRY CONSTRUCTION (LEVEL B QUALITY ASSURANCE)
-1. INSPECT REINFORCEMENT, INCLUDING PRESTRESSING
TENDONS, AND VERIFY PLACEMENT.
2. REINFORCING BAR WELDING:
X
X
ACI 318 CH. 20, 25.2,
REFERENCED
AWS D1.4
STANDARD
ACI 318: 26.6.4
1908.4
IBC
REFERENCE
TABLE 1705.3
REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
TYPE
NOT
APPLICABLE
CONTINUOUS
SPECIAL
INSPECTION
PERIODIC
SPECIAL
INSPECTION
a
25.3, 26.6.1-26.6.3
a. VERIFY WELDABILITY OF REINFORCING BARS
OTHER THAN ASTM A706;
b. INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM
5/16" AND
c. INSPECT ALL OTHER WELDS.
- X -x - -
3. INSPECT ANCHORS CAST IN CONCRETE - X ACI 318: 17.8.2- -
4. INSPECT ANCHORS POST-INSTALLED IN HARDENED
X -
CONCRETE MEMBERS.b
a. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY
OR UPWARDLY INCLINED ORIENTATIONS TO RESIST
SUSTAINED TENTION LOADS.
b. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN 4.a.
- X
ACI 318: 17.8.2.4
ACI 318: 17.8.2
5. VERIFY USE OF REQUIRED DESIGN MIX. - X - 1904.1, 1904.2,ACI 318: CH.19.
26.4.3, 26.4.4 1908.2, 1908.3
6. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS
FOR STRENGTH TESTS, PERFORM SLUMP AND AIR
CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF
THE CONCRETE
X - -
ASTM C172
ASTM C31 1908.10
ACI 318: 26.4,26.12
7. INSPECT CONCRETE AND SHOTCRETE PLACEMENT FOR
PROPER APPLICATION TECHNIQUES.
X - - ACI 318: 26.5
1908.6, 1908.7, 2908.8
8. VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE
AND TECHNIQUES.
- X - ACI 318: 26.5.3-26.5.5 1908.9
9. INSPECT PRESTRESSED CONCRETE FOR:
a. APPLICATION OF PRESTRESSING FORCES; AND
b. GROUTING OF BONDED PRESTRESSING TENDONS.
X - -
X - -
ACI 318: 26.10 -
10. INSPECT ERECTION OF PRECAST CONCRETE MEMBERS. - X - ACI 318: CH. 26.8 -
11. VERIFY IN-SITU CONCRETE STRENGTH, PRIOR TO STRESS-
ING OF TENDONS IN POST-TENSIONED CONCRETE AND
PRIOR TO REMOVAL OF SHORES AND FORMS FROM
BEAMS AND STRUCTURAL SLABS.
- X - ACI 318: 26.11.2 -
12. INSPECT FORMWORK FOR SHAPE, LOCATION AND
DIMENSIONS OF THE CONCRETE MEMBER BEING
FORMED.
- X - ACI 318: 26.11.1.2(b) -
FOR SI: 1 INCH = 25.4 MM
a. WHERE APPLICABLE, SEE ALSO SECTION 1705.12, SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE.
b. SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTION SHALL BE INCLUDED IN THE RESEARCH REPORT FOR THE ANCHOR ISSUED BY AN APPROVED SOURCE IN ACCORDANCE WITH 17.8.2 IN ACI 318, OR OTHER QUALIFICATION PROCEDURES. WHERE SPECIFIC REQUIREMENTS ARE NOT PROVIDED, SPECIAL INSPECTION REQUIREMENTS SHALL BE SPECIFIED BY THE REGISTERED DESIGN PROFESSIONAL AND SHALL BE APPROVED BY THE
BUILDING OFFICIAL PRIOR TO THE COMMENCEMENT OF THE WORK.
PERIODIC SPECIAL INSPECTION
REQUIRED VERIFICATION
SPECIAL INSPECTION(CONT.)
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
RC
TS
TS
KEY PLAN
hymanski Associates
S T R U C T U R A L E N G I N E E R S
, L.L.C.
Livonia, Michigan 48154 fx.ph.
33426 Five Mile Rd.
S
734.855.4809734.855.4810 email@sastructuralengineers.com
09/10/2025 BIDS
Livonia Public Schools Central Office Complex Monument Sign
Livonia, Michigan
2025-041
-0
L
PS
-C
EN
TR
AL
O
FF
IC
E
CO
MP
LE
X
MO
NU
ME
NT
S
IG
N
09/17/2025 ADDENDUM #1
FOUNDATION PLAN
FOUNDATION PLAN
X
(E)LP-A2
(E)TIMER
GENERAL DEMOLITION NOTES
A
THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL
EXTENT OF WORK TO BE PERFORMED. THE EXACT EXTENT OF
DEMOLITION SHALL BE DETERMINED BY THE NEW WORK.
B
ANY INTERRUPTIONS OF EXISTING SERVICES AND/OR EQUIPMENT SHALL
BE PERFORMED AT A TIME APPROVED IN ADVANCE BY OWNER'S
REPRESENTATIVE SO AS NOT TO INTERFERE WITH THE PRESENT
BUILDING'S OPERATION.
C
PRIOR TO COMMENCEMENT OF WORK, CONTRACTOR SHALL VISIT THE
SITE AND BECOME FAMILIAR WITH EXISTING SITE CONDITIONS,
SYSTEMS, AND UTILITIES. NOTIFY DESIGN PROFESSIONAL OF ANY
INTERFERENCES OR DISCREPANCIES.
D
ALL ITEMS INDICATED WITH CROSS-HATCHING SHALL BE REMOVED
COMPLETELY WITH ALL RELATED ITEMS INCLUDING HANGERS,
SUPPORTS, INSULATION, CONTROLS, ETC. CAP ALL OPEN-ENDED PIPES
AND DUCTS.
E
THE OWNER SHALL HAVE FIRST RIGHT OF REFUSAL ON ALL EQUIPMENT
BEING REMOVED. ALL ITEMS REMOVED SHALL BE LEGALLY DISPOSED OF.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXISTING
RELOCATED AND OWNER-PROVIDED EQUIPMENT.
F
VERIFY DEPTH, SIZE, LOCATIONS, AND CONDITIONS OF EXISTING
UTILITIES IN THE FIELD. INCLUDING POINTS OF CONNECTION PRIOR TO
STARTING WORK.
G
ALL ITEMS ON DEMOLITION PLAN SHALL BE CONSIDERED EXISTING
UNLESS OTHERWISE NOTED. ALL WORK INDICATED ON PLANS HAS BEEN
LOCATED PER EXISTING DRAWINGS AND/OR FIELD OBSERVATION AND
REQUIRES FIELD VERIFICATION.
H
ALL EXISTING WORK TO REMAIN SHALL BE PROTECTED FROM DAMAGE.
WHERE DUCT WORK PIPE INSULATION HAS BEEN DAMAGED DURING
DEMOLITION, THE CONTRACTOR SHALL REPAIR INSULATION AS
REQUIRED TO MATCH EXISTING.
DEMOLITION KEYED NOTES
SIGN BEING REMOVED COMPLETE BY OTHERS. ELECTRICAL CONTRACTOR
SHALL DISCONNECT AND MAKE SAFE. PROTECT CONDUIT AND WIRING.
PREPARE TO RE-USE CIRCUIT. REFER TO NEW WORK PLANS FOR
FURTHER INFORMATION.
JUNCTION BOX AND ALL ASSOCIATED COMPONENTS SHALL BE REMOVED
COMPLETE. DISCONNECT ALL CIRCUITS AND MAKE SAFE. PROTECT
CONDUIT AND WIRING AND PREPARE TO RE-WORK CONDUIT AND
INSTALL HAND HOLE AND NEW JUNCTION BOX. REFER TO NEW WORK
PLANS FOR FURTHER INFORMATION.
3 FLAG POLE LIGHT AND ALL ASSOCIATED COMPONENTS SHALL BE
REMOVED COMPLETE.
X
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
BIDS 08-22-2025
MPH
TJO
TJO
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
UNIFIED BUILDING
SYSTEMS ENGINEERING
UBS PROJECT 029.25.14
69 S. GRATIOT AVE.
MT. CLEMENS, MI 48043
ELECTRICAL SITE
DEMOLITION PLAN
ESD1.00
SCALE:
ELECTRICAL SITE DEMOLITION PLAN
1/16" = 1'-0"
Livonia Public Schools Central Office Complex Monument Sign
Livonia, Michigan
2025-041
-0
L
PS
-C
EN
TR
AL
O
FF
IC
E
CO
MP
LE
X
MO
NU
ME
NT
S
IG
N
09/10/2025 BIDS
X
(E)LP-A2
(E)TIMER
A
A
B
B
3 2
SITE PLAN GENERAL NOTES
A
FIELD VERIFY LOCATIONS OF EXISTING UNDERGROUND SERVICES TO
COORDINATE ALL POLE BASE LOCATIONS AND UNDERGROUND SERVICES
BEING INSTALLED UNDER THIS CONTRACT WITH CIVIL DRAWINGS PRIOR
TO INSTALLATION OF POLE BASES AND CONDUIT.
B
ALL THREE PHASE WIRES, NEUTRAL, AND GROUND SHALL BE RUN TO
LAST LIGHTING FIXTURE AND CAPPED FOR FUTURE EXPANSION.
C
ANY 120 VOLT BRANCH CIRCUIT FEEDER LONGER THAN 75'-0" TO LAST
DEVICE SHALL BE SIZED TO THE NEXT LARGER STANDARD AWG SIZE. E.C.
SHALL FIELD VERIFY ALL LENGTHS OF FEEDERS.
D ALL ELECTRICAL DEVICES ON THIS SHEET SHALL BE NEW UNLESS
OTHERWISE NOTED.
NEW WORK KEYED NOTES
PROVIDE NEW 12"H X 12"W X 6"D WEATHERPROOF JUNCTION BOX WITH
BACK PLATE AND REMOVABLE FRONT COVER. JUNCTION BOX IS TO BE
SURFACE MOUNTED TO THE MASONRY BASE OF THE SIGN. REWORK
EXISTING TO REMAIN CONDUIT AND WIRING AS REQUIRED. ALL
CONDUIT SHALL BE NEW.
GROUND MOUNTED LIGHT FOR MONUMENT SIGN. RE-USE A CIRCUIT AS
A RESULT OF DEMOLITION WORK. UPDATE PANEL SCHEDULE. REFER TO
LUMINAIRE SCHEDULE FOR FIXTURE TYPE. REFER TO ELECTRICAL
DETAILS FOR FURTHER INFORMATION ON INSTALLATION AND
MOUNTING.
GROUND MOUNTED LIGHT FOR FLAG POLE. RE-USE A CIRCUIT AS A
RESULT OF DEMOLITION WORK. UPDATE PANEL SCHEDULE. REFER TO
LUMINAIRE SCHEDULE FOR FIXTURE TYPE. REFER TO ELECTRICAL
DETAILS FOR FURTHER INFORMATION ON INSTALLATION AND
MOUNTING.
PROVIDE NEW HAND HOLE. EXTEND CONDUIT(S) AND WIRING FROM
HAND HOLE TO NEW JUNCTION BOX MOUNTED ON BACK OF SIGN.
RECONNECT ALL EXISTING TO REMAIN CIRCUITS, MATCH EXISTING
WIRING SIZE(S).
X
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
MPH
TJO
TJO
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
UNIFIED BUILDING
SYSTEMS ENGINEERING
UBS PROJECT 029.25.14
69 S. GRATIOT AVE.
MT. CLEMENS, MI 48043
ELECTRICAL SITE NEW
WORK PLAN
ES1.00
SCALE:
ELECTRICAL SITE NEW WORK PLAN
1/16" = 1'-0"
Livonia Public Schools Central Office Complex Monument Sign
Livonia, Michigan
2025-041
-0
L
PS
-C
EN
TR
AL
O
FF
IC
E
CO
MP
LE
X
MO
NU
ME
NT
S
IG
N
FLOOD LIGHTING BASE DETAIL
NO SCALE
REINFORCED ROUND
CONCRETE BASE
(3)#4 WITH #3 TIES
AT 12" O.C.
CONDUIT COUPLING
SCHED. 40 PVC
ENCASE STANCHION IN
CONCRETE BASE OVER
TOP OF CONDUITS
FINISH GRADE
CHAMFER
FLOOD LIGHT HOUSING
ADJUSTABLE KNUCKLE AND
ACCESS COVER CONNECTION
4"
3'-6" DEPTH MINIMUM
12" ROUND
C
(E)INTERMATIC 24-HOUR DIGITAL TIMER
(LOCATED IN BASEMENT NEXT TO PANEL LP-A2)
LIGHTING CONTACTOR
SQUARE D MODEL 8910DPA34V02 OR EQUIVALENT
120VAC COIL, (4) N.O. 575VAC RATED CONTACTS
LP-A2-19
SEQUENCE OF OPERATION:
NORMAL CONDITIONS - UNDER NORMAL CONDITIONS, THE CONTACTOR COIL IS DE-ENERGIZED AND
THE CONTACTS ARE OPEN. THE LIGHTS ARE NOT ON.
ACTIVATION - UPON THE INTERMATIC 24-HOUR DIGITAL TIMER ACTIVATING THE CONTACTOR COIL ENERGIZES AND ALL OF THE ASSOCIATED CONTACTS IN THE CONTACTOR ARE CLOSED TURNING THE
LIGHTS ON.
CONTACT STATUS IS SHOWN
WITH THE COIL DE-ENERGIZED (TYPICAL)
T1
T2
T3
LIGHTING CONTACTOR
NO SCALE
T4L4
L3
L2
L1
T
LP-A2-X
LP-A2-X
LP-A2-X
LP-A2-X (E) POLE LIGHTS
MONUMENT SIGN GROUND LIGHTS
FLAG POLE GROUND LIGHTS
SPARE
JUNCTION BOX BACK PLATE DETAIL
NO SCALE
LIGHTING CONTACTORFUSE HOLDER
BUSSMANN BMM603-1SQ OR EQUIVELANT
WITH FUSES AND SAFTEY PULLER
(E)CIRCUITS FROM LP-A2 LOAD WIRING
12"H X 12"W X 6"D SURFACE MOUNTED WEATHERPROOF
JUNCTION BOX WITH REMOVEABLE COVER
GRADE LINE
12"H X 12"W X 6"D SURFACE MOUNTED WEATHERPROOF
JUNCTION BOX WITH REMOVEABLE COVER
GRADE LINE
CONDUITS
54" 54"
MONUMENT SIGN BACK DETAIL
NO SCALE
MONUMENT SIGN SIDE DETAIL
NO SCALE
FLAG POLE DETAIL
NO SCALE
30"
30"
FLAG POLE
ELECTRICAL DETAILS
E5.00
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
MPH
TJO
TJO
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
UNIFIED BUILDING
SYSTEMS ENGINEERING
UBS PROJECT 029.25.14
69 S. GRATIOT AVE.
MT. CLEMENS, MI 48043
Livonia Public Schools Central Office Complex Monument Sign
Livonia, Michigan
2025-041
-0