250910 LPS CO Monument Sign Bid Drawings (25-041).pdf
PDF 4 MB Posted
- Attached to
- LPS Central Office Complex Monument Sign Bid
- Solicitation number
- RFP-LPS-250000003111-2
- Issued by
- Wayne County, Michigan
About this file
This document is a comprehensive bid set of construction drawings for the Livonia Public Schools Central Office Complex Monument Sign project located in Livonia, Michigan. The project involves replacing the existing monument sign with a new sign, including site demolition, electrical work, and landscaping restoration. The bid set is dated September 10, 2025, and includes architectural, structural, and electrical plans prepared by French Associates, Inc. The drawings provide detailed specifications for a new monument sign featuring brick veneer, cast stone caps, dimensional lettering, and integrated lighting.
The project includes a base bid for a stone sign and an alternate bid for an EPS foamcore sign sprayed with a hard coat. Electrical components include ground-mounted lights for the monument sign and flag pole, with a new junction box and rewiring of existing electrical infrastructure. The site work involves removing the existing sign, concrete sidewalk, and landscaping, with plans to reinstall salvaged concrete pavers and restore non-paved areas with topsoil and seeding. The drawings specify materials, colors, and construction details, with the Livonia Public Schools logo incorporated into the sign design. The project appears to be funded by the school district and is designed to update the central office complex's exterior signage and lighting.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LIST OF DRAWINGS
STRUCTURAL
A0.01 ARCHITECTURAL REFERENCE SHEET
A0.02 COMPOSITE CODE PLAN
A1.00 SITE PLAN
A1.01 SITE DETAILS
ARCHITECTURAL ELECTRICAL
LIVONIA PUBLIC SCHOOLS
CENTRAL OFFICE COMPLEX
MONUMENT SIGN
LIVONIA, MICHIGAN
2025-041
SEPTEMBER 10, 2025 BID SET
PROJECT NO.
c FRENCH ASSOCIATES, INC.
-0
L
PS
C
EN
TR
AL
O
FF
IC
E
- M O
N U
M
EN
T
SI
G N
S2.00 FOUNDATION PLAN E0.00 ELECTRICAL GENERAL INFORMATION
ESD1.00 ELECTRICAL SITE DEMOLITION PLAN
ES1.00 ELECTRICAL SITE NEW WORK PLAN
E5.00 ELECTRICAL DETAILS
15125 FARMINGTON RD
LIVONIA MICHIGAN, 48154
REFERENCE LOCATION MAP
ORIGINAL DRAWINGS PRINTED IN FULL COLOR
2'-
" M
IN
3'-
2" M
AX
STAIR HANDRAIL
1'-0"1'-0"
110.0
6.00.010.0
5'- 0" 6'-
0"
6'- 0"
5'- 0"
5'- 0"
M
IN
8'- 0"
M
AX
4" M
IN
2'-
" M
AX
DRINKING FOUNTAINS/ ELECTRIC WATER COOLER
TOILET ROOM SIGNAGE
3'- 3"
M
IN
3'- 0"
M
AX
.4'- 0"5'- 4"
D
IS
PE
N
SE
R
FIRE EXTINGUISHER EQUIPMENT
TOILET ROOM ACCESSORIES
PA
PE
R
SH
EL
F
SA
N
IT
AR
Y
D
IS
PE
N
SE
R
TO
W
EL
N
AP
KI
N
3'- 8"
M
AX
R
EC
EP
TA
C
LE
TR
AS
H
C
LO
TH
ES
D R
YE
R
H
AN
D
D
IS
PE
N
SE
R
SO
AP
H O
O
KS
2'-
" M
AX
2'-6" CLR.
MIN.
BARRIER FREE LAVATORIES AND MIRRORS
AN
D
/O R
C
AB
IN
ET
EX
TI
N G
U
IS
H
FI
R
E H
O
SE
VA
LV
E R
AC
K
O R
FI
R E
H O
SE
1'-6" MIN.
6'- 0"
M
IN
3'- 2"
M
AX
1'- 6"
M
AX
FI
R
E H
O
SE
EX
TI
N G
U
IS
H
FI
R
E
C
AB
IN
ET
VA
LV
E
2'-
" M
AX
2'-
5" M
IN
2'- 5"
M
IN
1'-6" MIN.
2'- 3"
M
IN
11" MIN.
8"
MIN.9"
M
IN
1'-6" MIN.
1'-3" MAX.
RT OR LEFT
2'-6" MIN.
3'- 2"
M
IN
4'-
0" M
AX
6'- 0"
M
IN
SHOWER UNIT
2'- 9"
3'-
0"
1/2 " C
UR
B
MA
X.
CONTROL AREA
60" MIN.
HOSE
2'-6" MIN.
1'- 5"
MA
X.
3'- 8"
M
AX
BARRIER FREE URINAL
SIDE OPENING
3'- 6"
CL
2'- 3"
5'- 0"
ALT.
LOC.
RAMP HANDRAIL
2'-
" M
IN
3'-
2" M
AX
1'-0" 1'-0"
5'-0" MIN.
STALL LAYOUT
3'- 6"
M
IN
1'-
0"
6" 3'-0" MIN.
3'- 6"
ELEVATORS
CENTER OPENING
LC
4" MAX.
5'- 0"
M
IN
1'- 3"
MI
N.
MOUNTING HEIGHTS
CONVENIENCE CONTROLS AND OUTLETS
BR
EA
KE
R
S C
IR
C
U
IT
SW
IT
C H
D
IM
M
ER
CL
CL
SE
C
U R
IT
Y
C O
N
TR
O L
C O
N
TR
O L
H
VA
C
LI
G
H T
SW
IT
C H
O U
TL
ET
S
FI
R
E
AL
AR
M
4'- 0"
M
AX
C
CL
L
IN
TE
R C
O M
CL
LENGTH OF
TREAD
BARRIER FREE WATER CLOSET
2'- 9"
3'-
0"
1'- 5"
1'-
7"
1'-6"
1'- 0"
MI
N.
2'- 9"
3'-
0"
4'- 0"
M
AX
1'- 5"
1'-
7"
1'- 3"
MI
N.
1'- 0"
MI
N.
7" MIN-9" MAX
36" MIN.
CL
12" MIN. 24' MIN.
42" MIN.
54" MIN.
39" - 41"
" M
IN
NOTE: HEIGHT ABOVE FLOOR TO BASELINE
OF CHARACTER TO COMPLY WITH ICC/ANSI
A117.1-2009 TABLE 703.2.4
M.B. T.B.T.B.
TACK BOARDS AND MARKER BOARDS
2'-0" AT KINDERGARTEN CLASSROOMS
2'-6" AT ELEMENTARY CLASSROOMS
3'-0" AT HIGH SCHOOL CLASSROOMS
INTERACTIVE PANEL
INTERACTIVE PANEL MOUNTING
2'- 8"
7"
12" MIN.
18" MAX.
" - 17
36" MIN.
CL
12" MIN. 24' MIN.
34" - 36"
" M
IN
24" - 42"
CL
42" MIN. 12"
MAX.
54" MIN.
" M
AX
" 1 1
/2"
CL
EA
R
BARRIER FREE WATER CLOSET
MOUNTING HEIGHTS FOR CHILDREN
CANE APRON AT
NON-ADA (WHERE
NOT PROTECTED IN
AN ALCOVE)
11"
MIN.
9" M
IN
3'- 0"
M
AX
8"
MIN.
1'-5" MIN.
2'- 3"
WITH OPTIONAL BOTTLE FILLER
ADA STANDARD
ABBREVIATIONSMATERIAL LEGEND
SCALE:
A
A2.20 A2.20
DETAIL LOCATOR
INTERIOR ELEVATION IDENTIFICATION
SHEET WHERE DETAIL IS
DRAWN
DRAWING SYMBOL
SYMBOL LEGEND
FOR CROSS-REFERENCING:
DETAIL IDENTIFICATION
SHEETS WHERE DETAIL IS CUT
DETAIL IDENTIFICATION
1" = 1'-0"
DETAIL TITLE
IDENTIFICATION
PLAN OR DETAIL
DETAIL IS DRAWN
SHEET WHERE
EXISTING
X
NEW
X
COLUMN GRID
FLOOR
ROOM
FLOOR
ROOM
A101
NAME
ROOM NAME AND NUMBER
DOOR IF MORE
BUILDING/UNIT
BUILDING/UNIT
BUILDING SECTION LOCATOR
PLAN OR DETAIL BLOW-UP
SHEET WHERE BUILDING
SECTION IS DRAWN
ELEVATION SYMBOL
BUILDING SECTION IDENTIFICATION
SHEET WHERE ELEVATION IS DRAWN
SHEET WHERE ELEVATION IS DRAWN
EXISTING DOOR
NOTE
CONSTRUCTION / DEMO
AREA OF PREVIOUS CHANGE
PER ROOMNEW DOOR
TYPE
PARTITION
x x
ITEM NUMBER
ADDENDUM (ADD), CONSTRUCTION CHANGE DIRECTIVE (CCD), OR
AREA OF CURRENT CHANGE
ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS (ASI)
MISCELLANEOUS SYMBOLS
DOOR NUMBER AND SYMBOLS
EQUIPMENT
TYPE
THAN ONE DOOR
EXTERIOR ELEVATION IDENTIFICATION
x xx x xx x xx x xx
A5.10
A
B
C
D X.X-X X
A101A
X-X12
AC AIR CONDITIONING
ACOUST ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AGG AGGREGATE
ALT ALTERNATE
AL/ALUM ALUMINUM
ANOD ANODIZED
APC ARCHITECTURAL PRECAST LINTEL
APPROX APPROXIMATE
ARCH ARCHITECT(URAL)
ASPH ASPHALT
AV AUDIO/VISUAL
L ANGLE
B CMU BURNISHED CMU
BIT BITUMINOUS
BD BOARD
BF BARRIER FREE
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BENCH MARK/BEAM
BOT BOTTOM
BRG BEARING
BUR BUILT-UP ROOF
CAB CABINET
CUH CABINET UNIT HEATER
CB CHALKBOARD/CATCH BASIN
CEM CEMENT
CER CERAMIC
CFM CUBIC FEET PER MINUTE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
COMP COMPACTED
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS/CONTINUE
CONTR CONTRACTOR
CORR CORRUGATED
CPL CEMENT PLASTER
CPT CARPET
CT CERAMIC TILE
CU CONDENSING UNIT
CUSP CUSPIDOR
CWF CURTAINWALL FRAMING
D DEPTH/DEEP
° DEGREE
DC DISPLAY CASE
DEMO DEMOLISH/DEMOLITION
DTL DETAIL
DF DRINKING FOUNTAIN
DIA/Ø DIAMETER
DIM DIMENSION
DIV DIVISION
DS DOWNSPOUT
DWG DRAWING
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC(AL)
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
EIFS EXTERIOR INSULATION FINISH
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EX/EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FD FLOOR DRAIN
FEC FIRE EXTINGUISHER CABINET
FF FORCED FLOW CABINET HEATER
FHC FIRE HOSE CABINET
FIN FINISH
FIN FL FINISH FLOOR
FLR FLOOR
FOUND FOUNDATION
FT/' FEET
FTG FOOTING
FRP FIBERGLASS REINFORCED
POLYESTER
GA GAUGE
GALV GALVANIZE(D)
GB GRAB BARS
GHT GLAZED HOLLOW TILE
GL GLASS
GLCMU GLAZED CMU
GLZD GLAZED
GYP GYPSUM
H/HGT HEIGHT
HB HOSE BIB
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HR HOUR
HVAC HEATING/VENTILATING/AIR
CONDITIONING
ID INSIDE DIAMETER
IN/" INCH
INCL INCLUDE(D),(ING)
INSUL INSULATION/INSULATE(D)
INT INTERIOR
JST JOIST
JT JOINT
KIT KITCHEN
L LENGTH
LAM LAMINATE(D)
LAV LAVATORY
LB/# POUND
LGF LIGHT GAUGE FRAMING
LIN LINOLEUM
LKR LOCKER
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMC LINEAR METAL CEILING
LOC LOCATION(S)
LP LOW POINT
MANUF MANUFACTURER
MAR MARBLE THRESHOLD
MB MARKER BOARD
MAS MASONRY
MAT MATERIAL/MAT
MAU MAKE UP AIR UNIT
MAZ MAXIMUM
MECH MECHANICAL
MEZZ MEZZANINE
MIN MINIMUM/MINUTE
MISC MISCELLANEOUS
ML MASONRY LINTEL
MP METAL PANEL
MWP METAL WALL PANEL
MO MASONRY OPENING
MET/MTL METAL
MSF METAL STUD FRAMING
MT METAL THRESHOLD
NIC NOT IN CONTRACT
NO/# NUMBER
NOM NOMINAL
NSF NON-SLIP FINISH
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OHD OVERHEAD DOOR
OPNG OPENING
OPP OPPOSITE
OS OVERFLOW SUMP
PART PARTICLE
PART'N MOVABLE PARTITION
PC PRECAST CONCRETE
PL PLATE/PROPERTY LINE
PLAS PLASTER
PLAM PLASTIC LAMINATE
PLYWD PLYWOOD
PREFAB PREFABRICATED
PREFIN PREFINISHED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PTD PAINTED
PVC POLYVINYL CHLORIDE
QT QUARRY TILE
R RISER/RADIUM
RB RESILIENT WALL BASE/RUBBER BASE
RBF RUBBER FLOORING
RC RAIN CONDUCTOR
RES RESILIENT
RS ROOF SUMP
REF REFERENCE
REFR REFRIGERATOR
REINF REINFORCING
REQ'D REQUIRED
REV REVISION(S)
RF ROOF EXHAUST FAN
RM REMOVABLE MULLION/ROOM
RO ROUGH OPENING
RWO RIGHT OF WAY
RTU ROOF TOP UNIT
RV ROOF VENT
S SINK
SAAC SPRAY APPLIED ACOUSTICAL COATING
SCHED SCHEDULE
SEAL CONCRETE SEALER
SEC SECTION
SFF STOREFRONT FRAMING
SHT SHEET
SIM SIMILAR
SPEC(S) SPECIFICATIONS
SP CMU SPLIT FACE CMU
SPI SPORTS IMPACT FLOORING
SPKR SPEAKER
SQ SQUARE
SS SERVICE SINK/STAINLESS STEEL
SSM SOLID SURFACE MATERIAL
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SUSP SUSPENDED
SVT SOLID VINYL TILE
SV SHEET VINYL
T TREAD
T&B TOP AND BOTTOM
TB TACK BOARD
TC TOP OF CURB
TEMP TEMPERED
TER TERRAZZO
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOS TOP OF STEEL
TS TUBE STEEL
TV TELEVISION
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
UV UNIT VENTILATOR
VCT VINYL COMPOSITION TILE
VCG VINYL COVERED GYPSUM BOARD
VERT VERTICAL
VIF VERIFY IN FIELD
VUV VERTICAL UNIT VENTILATOR
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WDSC WOOD SOUND CONTROL
WH WATER HEATER
WP WORKING POINT / WATERPROOF
WWF WELDED WIRE FABRIC
SOIL
ASPHALT AGGREGATE
GRANULAR FILL
STONE/GRAVEL
CONCRETE
CONCRETE MASONRY UNIT
BRICK
GLAZED HOLLOW CMU
STRUCTURAL GLAZED TILE
LIMESTONE
MARBLE
FINISH WOOD
COMPOSITION/PLYWOOD
CONTINUOUS WOOD BLOCKING
BLOCKING OR SHIMS
BATT INSULATION
RIGID INSULATION
PREMOLDED EXPANSION JOINT/
COMPRESSIBLE FILLER STRIP
PLASTER OR GYPSUM BOARD
CERAMIC OR QUARRY TILE
TERRAZZO
ACOUSTICAL PANEL OR ACOUSTICAL TILE
EXISTING MATERIAL (IN SECTION)
EXISTING MATERIAL (IN PLAN)
DEMOLITION - TO BE REMOVED
KEY PLAN
ARCHITECTURAL
REFERENCE
SHEET
A0.01
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
GRS
AMN
DCJ
KEY PLAN
09/10/2025 BIDS
Livonia Public Schools Central Office Complex Monument Sign
Livonia, Michigan
2025-041
-0
L
PS
-C
EN
TR
AL
O
FF
IC
E
CO
MP
LE
X
MO
NU
ME
NT
S
IG
N
CODE PLAN INFORMATION
EXISTING BUILDING AREA IS NOT CHANGING.
BUILDING IS NOT STUDENT OCCUPIED - ADMINISTRATION STAFF ONLY.
NO CHANGE OF USE
EXISTING BUILDING IS NOT SPRINKLED.
ALTERATION DESCRIPTION:
REPLACEMENT OF EXISTING MONUMENT SIGN WITH NEW.
BUILDING INFORMATION
CODE PLAN LEGEND
1) DESIGN CODES
a)2021 MICHIGAN REHABILITATION CODE (EXISTING BUILDING) b)NFPA 101 LIFE SAFETY CODE 2012 EDITION c)2021 MICHIGAN PLUMBING CODE d)2021 MICHIGAN MECHANICAL CODE e)2021 MICHIGAN UNIFORM ENERGY CODE
f) 2023 MICHIGAN ELECTRICAL CODE RULES, PART 8 g)2023 NATIONAL ELECTRICAL CODE (NFPA 70) h)2017 ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS & FACILITIES
2) DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE (106.6)
a)A REPRESENTATIVE OF FRENCH ASSOCIATES WILL BE THE DESIGN PROFESSIONAL IN
RESPONSIBLE CHARGE.
4) COMPLIANCE METHOD (CHAPTER 3)
a)WORK AREA COMPLIANCE METHOD (301.1.2) - THE WORK SHALL COMPLY WITH THE
APPLICABLE REQUIREMENTS OF CHAPTERS 5 THROUGH 11.
5) CLASSIFICATION OF WORK (CHAPTER 5)
a)AS DEFINED BY THE MICHIGAN REHABILITATION CODE, THE WORK INCLUDES LEVEL 1
ALTERATIONS AND LEVEL 2 ALTERATIONS. THE WORK AREA DOES NOT EXCEEDS 50%
OF THE BUILDING AREA.
b)THERE IS NO CHANGE OF OCCUPANCY.
c)THERE IS NO ADDITION.
d)UNDER THE SCHOOL FIRE SAFETY RULES, THE SCOPE OF WORK IN THE LEVEL 1
ALTERATIONS IS THE REPLACEMENT OF EXISTING FINISHES AND SYSTEMS. AS A
RESULT, THE LEVEL 1 ALTERATION AREAS DO NOT QUALIFY AS REMODELING.
e)THE LEVEL 2 ALTERATION AREAS ARE BEING REMODELED AS DEFINED BY THE
SCHOOL FIRE SAFETY RULES. THE LEVEL 2 ALTERATION AREA IS LESS THAN 50% OF
THE BUILDING AREA SO WE ARE NOT REQUIRED TO BRING THE WHOLE BUILDING INTO
COMPLIANCE.
6) CHAPTER 7- ALTERATIONS- LEVEL 1
a)SECTION 702.1- NEW INTERIOR FINISHES WILL COMPLY WITH CHAPTER 8 OF THE
MICHIGAN BUILDING CODE.
i) FROM TABLE 803.9- CORRIDORS ARE CLASS B FINISHES, ROOMS ARE CLASS C
FINISHES
b)INTERIOR FLOOR FINISHES SHALL COMPLY WITH SECTION 804 OF MBC.
7) CHAPTER 8- ALTERATIONS- LEVEL 2
a)SECTION 803.4- NEW INTERIOR FINISHES WILL COMPLY WITH CHAPTER 8 OF THE
MICHIGAN BUILDING CODE.
i) FROM TABLE 803.9- CORRIDORS ARE CLASS B FINISHES, ROOMS ARE CLASS C
FINISHES
b)803.4.1- THE NEW AND EXISTING FINISHES OF CORRIDORS SERVING THE WORK AREA
COMPLY WITH SECTION 804 OF MBC.
c)SECTION 804- FIRE PROTECTION
i) 804.2.2- IN WORK AREAS, THE FIRE PROTECTION (SPRINKLER) SYSTEM WILL BE
MODIFIED AS REQUIRED TO COMPLY WITH THE MICHIGAN BUILDING CODE.
ii) 804.4- THE EXISTING BUILDING HAS AN EXISTING, PREVIOUSLY APPROVED FIRE ALARM
SYSTEM (EXCEPTION 1).
iii) 804.4.1.1 THE EXISTING FIRE ALARM SYSTEM IS ALREADY IN PLACE IN THE WORK
AREAS AND SHALL BE MAINTAINED. MODIFICATIONS SHALL COMPLY WITH SECTION 907
OF THE MBC.
d)SECTION 805.3- THE EXISTING NUMBER OF EXITS BEING MAINTAINED COMPLY WITH
MBC CHAPTER 10 REQUIREMENTS FOR QUANTITY AND SIZING.
e)SECTION 805.5- CORRIDOR DOORS IN THE WORK AREA THAT ARE BEING REPLACED
SHALL BE SOLID CORE WOOD OR HOLLOW METAL AND SHALL NOT CONTAIN LOUVERS.
f) 805.5.3- OTHER CORRIDOR OPENING- THE EXISTING CORRIDOR WALLS PROVIDE A
SMOKE BARRIER SEPARATION. NEW CORRIDOR OPENINGS SHALL MAINTAIN THE
SMOKE BARRIER.
g)805.6- DEAD END CORRIDORS IN THE WORK AREAS DO NOT EXCEED 35' h)805.7- MEANS OF EGRESS AND EMERGENCY LIGHTING ARE PROVIDED AS REQUIRED IN
THE LEVEL 1 AND LEVEL 2 ALTERATION AREAS
i) 805.8- EXIT SIGNS AS PROVIDED AS REQUIRED IN THE LEVEL 1 AND LEVEL 2
ALTERATION AREAS.
REPLACEMENT OF EXISTING EXTERIOR MONUMENT SIGN
KEY PLAN
COMPOSITE
CODE PLAN
A0.02
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
GRS
AMN
DCJ
KEY PLAN
09/10/2025 BIDS
Livonia Public Schools Central Office Complex Monument Sign
Livonia, Michigan
2025-041
-0
L
PS
-C
EN
TR
AL
O
FF
IC
E
CO
MP
LE
X
MO
NU
ME
NT
S
IG
N
SCALE:
COMPOSITE CODE PLAN
3/32" = 1'-0"
REMOVE AND SALVAGE
CONCRETE PAVERS
REINSTALL SALVAGED
CONCRETE PAVERS AFTER
CONSTRUCTION TO MATCH
ORIGINAL DESIGN
INSTALL NEW MULCH
REMOVE EXISTING MULCH
AND PLANTS
REMOVE EXISTING
CONCRETE SIDEWALK
INSTALL NEW CONCRETE
SIDEWALK. ADD CONCRETE
CONTROL JOINTS ( SIMILAR
TO EXISTING)
EXISTING FLAG POLE TO
REMAIN
REMOVE EXISTING
MONUMENT SIGN
INCLUDING BASE AND
FOUNDATION, REMOVE
ELECTRICAL JUNCTION
BOX AND LIGHT. REFER
TO ELECTRICAL10'-0"
3'-0"
8'-5"
10"
+/-R10'-0"
Ø15'-0"
R10'-0"
REMOVE AND SALVAGE
CONCRETE PAVERS
REMOVE EXISTING MULCH
AND PLANTS
REMOVE EXISTING
CONCRETE SIDEWALK
EXISTING FLAG POLE TO
REMAIN
REMOVE EXISTING
MONUMENT SIGN
INCLUDING BASE AND
FOUNDATION, REMOVE
ELECTRICAL JUNCTION
BOX AND LIGHT. REFER
TO ELECTRICAL
INSTALL NEW MONUMENT
SIGN - REFER TO A1.01
-2
'-6
LIGHTING FIXTURES.
REFER TO ELECTRICAL
FOR COORDINATION.
-2
'-6
RESTORE ALL NON-PAVED AREAS WITH 3" OF CLEAN TOPSOIL AND SEED
MIX (30% KENTUCKY BLUEGRASS, 20% PERENNIAL RYE GRASS, 50%
CREEPING RED FESCUE). PLACE MULCH IN ALL SEEDED AREAS ON
SLOPES IN EXCESS OF 10 HORIZONTAL TO 1 VERTICAL PLACE NORTH
AMERICAN GREEN DS150 MULCH BLANKET IMMEDIATELY AFTER
SEEDING. USE METAL STAPLES PER MANUFACTURERS
RECOMMENDATIONS TO HOLD MATTING IN PLACE
1. EARTHWORK AND PAVEMENT CONSTRUCTION SHALL BE
PERFORMED IN ACCORDANCE WITH THE CURRENT MDOT
STANDARD SPECIFICATIONS FOR CONSTRUCTION
2. REMOVE ANY EXISTING TOPSOIL, VEGETATION, TREES AND OTHER
DELETERIOUS MATERIALS TO EXPOSE TO THE SUBGRADE SOIL.
TREE ROOTS SHALL BE COMPLETELY REMOVED.
3. EXCAVATE TO THE DEPTH OF THE FINAL SUBGRADE ELEVATION TO
ALLOW FOR GRADE CHANGES AND THE PLACEMENT OF THE
RECOMMENDED PAVEMENT SYSTEM.
4. THE TOP 12" OF THE EXPOSED SUBGRADE SHALL BE COMPACTED
TO A DENSITY NOT LESS THAN 95% OF THE MAXIMUM DENSITY AS
DETERMINED BY THE MODIFIED PROCTOR (ASTM D 1557-91)
5. THE FINAL SUBGRADE SHALL BE THOROUGHLY PROOF ROLLED
UNDER THE OBSERVATION OF A GEOTECHNICAL/PAVEMENT
ENGINEER. LOOSE OR YIELDING AREAS WHICH CANNOT BE
MECHANICALLY STABILIZED SHALL BE REMOVED AND REPLACED
WITH ENGINEERED FILL OR AS INDICATED BY FIELD CONDITIONS,
6. THE AGGREGATE BASE SHALL BE COMPACTED TO A DENSITY NOT
LESS THAN 95% OF THE MAX. DENSITY AS DETERMINED BY THE
MODIFIED PROCTOR (ASTM D 1557-91). THE BASE SHALL EXTEND A
MIN. OF 1 FOOT BEYOND THE PAVED BASE.
7. PLACE EXPANSION JOINTS WHERE NEW CONCRETE PAVEMENT OR
WALKS ABUT BUILDING WALLS, CURB, OR EXISTING CONCRETE
PAVEMENT. PLACE JOINT SEALANT ON ALL EXPANSION JOINTS.
8. CONTRACTOR TO CONSTRUCT CONTRACTION AND EXPANSION
JOINTS IN ALL NEW CONCRETE PAVEMENT. CONTRACTION JOINTS
SHALL BE TOOLED WHERE SIDEWALKS WIDTH IS 8' OR LESS, AND
SHALL BE SPACED EQUAL TO THE WIDTH OF THE PAVEMENT, BUT
NOT MORE THAN 10' APART. PLACE EXPANSION JOINTS WITH JOINT
SEALANT AT MAX. 50" SPACING. CONTRACTOR SHALL GENERALLY
MATCH THE JOINT PATTERNS FOR CONCRETE PAVEMENT WHEN
SHOWN ON THE PLANS.
9. CONCRETE PAVEMENT SHALL MEET THE REQUIREMENTS FOR MDOT
GRADE P1 CONCRETE PER THE CURRENT MDOT STANDARD
SPECIFICATIONS FOR CONSTRUCTION.
PAVING CONSTRUCTION NOTES
RESTORATION NOTE
DEMOLITION AND
NEW WORK SITE
PLANS
A1.00
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
GRS
AMN
DCJ
KEY PLAN
09/10/2025 BIDS
Livonia Public Schools Central Office Complex Monument Sign
Livonia, Michigan
2025-041
-0
L
PS
-C
EN
TR
AL
O
FF
IC
E
CO
MP
LE
X
MO
NU
ME
NT
S
IG
N
SCALE:
NEW WORK SITE PLAN
1/2" = 1'-0"
SCALE:
DEMOLITION SITE PLAN
1/2" = 1'-0"
A A1.00
SCALE:
EXISTING SIGN
N.T.S A
A1.00
A1.01
E
G A1.01
F A1.01
A1.00 A
A1.01 E
CAST STONE CAP COLOR A
(LIMESTONE)
GRADE LINE
EL. 100'-0"
T.O. MASONRY
EL. 102'-0"
SCALE:
ELEVATION
3/4" = 1'-0" F
B
7'- 0"
2'- 0"
CAST STONE CAP COLOR B (BLUE
STAIN)
3'- 0 1
/4" 1'-
0 1 /4"
BASE BID : STONE SIGN (WHITE)
A1 ALTERNATE : EPS
FOAMCORE SPRAYED WITH
POLY ARMOR HARD COAT
5 1 /4"
5 1 /4"
3 1 /2"
DUAL SIDED
EMBOSSED CUSTOM DISTRICT
LOGO (BOTH SIDES)
2'- 0 1
/4"
1"
2"
4"
BRICK VENEER (BR-1)
4 3 /8"
1" DEEP EXTENDED LETTERS
FROM FACE OF SIGN (BLUE)
DIMENSIONAL LETTERS (BLUE
TO MATCH BR-2)
GLAZED BLUE BRICK (BR-2)
A1.01 H
CAST STONE CURVED TOP (BLUE
STAIN)
JUNCTION BOX. REFER TO
ELECTRICAL FOR COORDINATION.
SECTION
E
2'-0"
3'- 6"
M
IN
IM
UM
J
REINFORCED CONCRETE
FOOTING
(3) #5 BARS TOP & BOTTOM
STONE SIGN
ATTACHMENT REQUIREMENTS
PER SIGN MANUFACTURER
2'- 0"
STONE CURVED TOP (BLUE
STAIN)
PLAN SECTION
A
PLAN SECTION
B
10'-4"
1'-
10'-7 1/2"
2'- 2"
2'- 0"
1" 1"
CAST STONE TOP-
COLOR A (LIMESTONE)
LINE OF BRICK
WALL BELOW
10'-9 1/2"
1"1"
BRICK VENEER (BR-1)
12" CMU
#5 AT 24" O.C.
TOP VIEW
C
STONE TOP-
COLOR B (BLUE STAIN)
CAST STONE TOP-
COLOR A (LIMESTONE)
2'-0"
JUNCTION BOX. REFER TO
ELECTRICAL FOR
COORDINATION.
JUNCTION BOX. REFER TO
ELECTRICAL FOR
COORDINATION.
JUNCTION BOX. REFER TO
ELECTRICAL FOR
COORDINATION.
LINE OF SIGN BELOW
SECTION DETAIL
1" = 1'-0"
CAVITY WALL DRAINAGE SYSTEM
LAMINATED SHEET FLASHING
OPEN HEAD WEEP JOINT
DAMPPROOFING - EXTEND 4" BELOW
BRICK LEDGE
GROUT CAVITY SOLID
GROUT SOLID BELOW FLASHING
BRICK VENEER (BR-1) ON CMU BACK UP
W/ BRICK TIES
ADHESIVE-SET MEMBRANE FLASHING
CAST STONE CAP (COLOR A)
3/8" DIA STAINLESS STEEL ROD TIES (2)
PER PIECE OF CAP GROUT INTO CAP &
WALL. PROVIDE SEALANT AT FLASHING
PENETRATIONS
BACKER ROD AND SEALANT, TYP.
#5 AT 24" O.C. DOWEL. EXTEND
FULL HEIGHT, GROUT
REINFORCED CORE SOLID
DRIP EDGE
2'-0"
2"
4 5/8"1" 1 1/2" 11 5/8" 4 5/8" 1"1 1/2"
DESIGN PERSPECTIVE FOR REFERENCE
N.T.S.
D
H
REINFORCED CONCRETE
FOOTING
(3) #5 BARS TOP & BOTTOM
4x4 GALV. TUBE STEEL FOR
SIGN SUPPORT BY SIGN
CONTRACTOR
J A1.01
BOND BEAM W/
2 - #5 CONTINUOUS
HORIZONTAL JOINT
REINFORCING AT 16"
O.C. VERTICALLY
#5 VERTICAL AT EACH
CORNER
SEALANT & BACKER ROD
EACH SIDE
BRICK VENEER ON 6" CMU,
SOLID GROUT CAVITY
SPACE FOR COMPOSITE
MASONRY WALL
ADHESIVE- SET
MEMBRANE FLASHING
A1 ALTERNATE
G
2'-0"
3'- 6"
M
IN
IM
UM
REINFORCED CONCRETE
FOOTING
(3) #5 BARS TOP & BOTTOM
EPS FOAMCORE SPRAYED
WITH POLY ARMOR HARD COAT
ATTACHMENT REQUIREMENTS
PER SIGN MANUFACTURER
(WHITE FINISH)
2'- 0"
EPS FOAMCORE SPRAYED
WITH POLY ARMOR HARD COAT
CURVED TOP (BLUE)
MONUMENT COLOR FINISH SCHEDULE
ITEM COLOR#
1. SHERWIN WILLIAMS SW 6804 DIGNITY BLUE
2.
DIMENSIONAL LETTERS
3.
GLAZED BRICK ELGIN BUTLER #2200A COBALT BLUE
BRICK VENEER BELDEN BRICK - GARDEN BLEND (VERIFY - TO MATCH EXISTING)
KEY PLAN
SITE DETAILS
A1.01
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
GRS
AMN
DCJ
KEY PLAN
09/10/2025 BIDS
Livonia Public Schools Central Office Complex Monument Sign
Livonia, Michigan
2025-041
-0
L
PS
-C
EN
TR
AL
O
FF
IC
E
CO
MP
LE
X
MO
NU
ME
NT
S
IG
N
D, E A1.01
D, E
S2.00
1SECTION
S2.00
2WALL REINFORCING DETAIL
TYPICAL
S2.00
MASONRY CONSTRUCTION DETAIL
S2.00
REINFORCED
G E N E R A L N O T E S
GENERAL CONDITIONS
1. IF ANY GENERAL NOTE CONFLICTS WITH ANY DETAIL OR NOTE ON THE PLANS
OR IN THE SPECIFICATIONS, THE STRICTEST PROVISION SHALL GOVERN.
2. THE STRUCTURAL DRAWINGS ARE FOR THE PLACEMENT AND SIZE OF STRUCTURAL
COMPONENTS ONLY. O.S.H.A., LOCAL GOVERNMENT CODES AND SAFETY CODE
REQUIREMENTS SHALL BE ADHERED TO BY THE CONTRACTOR.
3. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER IT IS
FULLY COMPLETED. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO
DETERMINE ERECTION PROCEDURE AND SEQUENCE, AND TO ENSURE THE SAFETY
OF THE STRUCTURE AND ITS COMPONENT PARTS DURING ERECTION. THIS
INCLUDES PROVIDING TEMPORARY BRACING, SHORING, GUYS OR TIE- DOWNS.
THESE TEMPORARY SUPPORTS WILL REMAIN IN PLACE UNTIL ALL STRUCTURAL
COMPONENTS ARE IN PLACE AND COMPLETED.
4. USE OF ENGINEERING DRAWINGS AS ERECTION DRAWINGS BY THE CONTRACTOR
IS STRICTLY PROHIBITED. DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS
ARE FOR REFERENCE ONLY AND SHOULD NOT BE USED FOR BUILDING LAYOUT AND
LOCATION. SEE ARCHITECTURAL DRAWINGS AND SITE PLAN FOR THESE PURPOSES.
5. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AT THE RATE OF NO MORE
THAN 80 DRAWINGS PER WEEK. THE CONTRACTOR SHALL SUBMIT A SCHEDULE OF
SHOP DRAWINGS PRIOR TO SUBMITTAL. THE CONTRACTOR SHALL CHECK SHOP
DRAWINGS PRIOR TO SUBMITTAL AND IS SOLELY RESPONSIBLE FOR ERRORS &
OMISSION IN THE PREPARATION OF SHOP DRAWINGS TO CONFORM TO THE DESIGN
DRAWINGS. SUBMIT ELECTRONIC SHOP DRAWINGS FOR ENGINEER REVIEW.
6. IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL RELEVANT DIMENSIONS
AND ELEVATIONS FOR EQUIPMENT INSTALLATIONS AGAINST PURCHASED
MANUFACTURER'S CERTIFIED EQUIPMENT DRAWINGS. DIMENSIONS THAT DEPEND
UPON SPECIFIC EQUIPMENT SUCH AS ELEVATOR OPENINGS, MECHANICAL
EQUIPMENT SUPPORTS, ETC. SHALL BE COORDINATED BY THE CONTRACTOR PRIOR
TO SUBMITTAL TO THE ARCHITECT/ENGINEER. SUCH DIMENSIONS SHALL BE
PROVIDED ON THE SHOP DRAWINGS BY THE CONTRACTOR PRIOR TO SUBMITTAL TO
THE ARCHITECT/ENGINEER.
EXISTING CONDITIONS
1. VERIFY ALL EXISTING ASSUMED DIMENSIONS AND CONDITIONS (I.E. EXISTING
MATERIALS; FRAMING MEMBER SIZES AND LOCATIONS; METHODS OF
CONSTRUCTION; ETC.) AT THE SITE PRIOR TO CONSTRUCTION AND FABRICATION.
IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE PROCEEDING WITH
WORK.
FOUNDATIONS
1. FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED SOIL WITH A SAFE BEARING
CAPACITY OF P.S.F. IF SOIL OF THIS CAPACITY IS NOT FOUND AT THE
ELEVATIONS INDICATED, FOOTINGS SHALL BE ENLARGED OR LOWERED AT THE
DIRECTION OF THE ARCHITECT. VERIFY FOUNDATION SOIL BEARING PRESSURE IN
FIELD BY SOILS ENGINEER.
2. PROVIDE NECESSARY SHEETING SHORING BRACING, ETC. AS REQUIRED DURING
EXCAVATIONS TO PROTECT SIDES OF EXCAVATIONS.
3. COMPLY FULLY WITH REQUIREMENTS OF OSHA AND OTHER REGULATORY
AGENCIES FOR SAFETY PROVISIONS.
CONCRETE
1. MINIMUM CONCRETE STRENGTH TO BE 3000 P.S.I. @ 28 DAYS, U.O.N.;
SLABS SHALL BE 3500 P.S.I. MIN. U.O.N. EXPOSED CONCRETE SHALL BE 4000 PSI
WITH 6% + 1% ENTRAINED AIR U.O.N.
3. ALL CONCRETE WORK AND PLACEMENT SHALL CONFORM TO THE LATEST
RECOMMENDATIONS OF A.C.I.
4. ALL REINFORCING BARS, DOWELS AND TIES SHALL CONFORM TO A.S.T.M. A615
GRADE 60. REINFORCING STEEL SHALL BE CONTINUOUS AND SHALL HAVE
MINIMUM 36 BAR DIAMETER LAP AND BE FABRICATED AND PLACED IN
ACCORDANCE WITH A.C.I. - 315 LATEST EDITION.
5. REINFORCED CONCRETE WALL FOOTINGS SHALL HAVE CORNER BARS
AT ALL INTERSECTIONS OF THE SAME SIZE AND SPACING AS THE MAIN
HORIZONTAL REINFORCING.
6. CONCRETE CONTRACTOR SHALL INCLUDE IN HIS COST ADDITIONAL CONCRETE
QUANTITY AS REQUIRED TO COMPENSATE FOR DEFLECTIONS OF METAL DECK AND
UNSHORED COMPOSITE BEAMS AND TO PROVIDE A LEVEL CONCRETE SURFACE.
7. FIELD AND SHOP TESTING OF CONCRETE WORK SHALL INCLUDE INSPECTION OF
REINFORCING STEEL PLACEMENT, REBARS, NUMBER, LOCATION, AND LAP SPLICE
LENGTH.
8. PROVIDE DOWELS INTO FOUNDATION TO MATCH SIZE AND SPACING OF VERTICAL
REINFORCEMENT AT ALL COLUMNS AND WALLS, UNLESS OTHERWISE NOTED.
MASONRY
9. UNLESS OTHERWISE SHOWN, PROVIDE THE FOLLOWING COVER FOR
REINFORCING STEEL:
A. UNFORMED SURFACES IN CONTACT WITH EARTH -3 IN.
B. UNFORMED SURFACES OVER MOISTURE BARRIERS -2 IN.
C. FORMED SURFACES EXPOSED TO EARTH OR WEATHER
OR WATER PROOFING/DAMP PROOFING
#6 OR LARGER -2 IN.
#5 OR SMALLER -1 1/2 IN.
D. FORMED SURFACES NOT EXPOSED TO EARTH
OR WEATHER
SLABS AND WALLS -3/4 IN.
COLUMNS -1 1/2 IN.
BEAMS AND GIRDERS -1 1/2 IN.
1. THE MASONRY PORTIONS OF THIS STRUCTURE ARE DESIGNED ACCORDING TO THE
LATEST ALLOWABLE STRESS DESIGN PROVISIONS OF THE MASONRY STANDARDS JOINT
COMMITTEE (MSJC) BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES
(ACI 530/ASCE 602) INCLUDING SECTIONS 2106 AND 2107 OF CHAPTER 21 IN THE
MICHIGAN BUILDING CODE. MASONRY COMPONENTS HAVE BEEN
DESIGNED ACCORDING TO THE PROVISIONS FOR SEISMIC DESIGN CATEGORY B.
2. ALL STRUCTURAL MASONRY IS TO BE CONSTRUCTED IN ACCORDANCE WITH THE
LATEST MASONRY STANDARDS JOINT COMMITTEE (MSJC) BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES (TMS 402/ACI 530/ASCE 5) AND
SPECIFICATIONS FOR MASONRY STRUCTURES (TMS 602/ACI 530.1/ASCE 6)
MASONRY SUBMITTALS ARE REQUIRED BY ACI 530.1/ASCE 6/TMS 602. SECTION 1.5
MASONRY TESTING AND INSPECTIONS ARE REQUIRED BY ACI 530.1/ASCE 6/TMS 602
SECTION 1.6, TABLE 5.
3. ALL STRUCTURAL MASONRY HAS BEEN ENGINEERED IN ACCORDANCE WITH
CHAPTER 2 ALLOWABLE STRENGTH DESIGN. COMPRESSION STRENGTH SHALL BE
DETERMINED ACCORDING TO THE UNIT STRENGTH METHOD FOR CONCRETE
MASONRY MSJC SECTION 1.4. B.2.b.
4. ALL BLOCK SHALL CONFORM TO ASTM C90, TYPE I, WITH A MINIMUM UNIT NET
AREA COMPRESSIVE STRENGTH OF 2000 PSI.
5. MASONRY COMPRESSIVE STRENGTH f'm = 2000 PSI MINIMUM.
6. MORTAR SHALL BE TYPE "S" (1800 PSI) CONFORMING TO ASTM C-270.
USE MORTAR CEMENT WHERE EXTERIOR WALLS ARE UNREINFORCED.
7. PROVIDE HORIZONTAL WIRE TYPE REINFORCING WITH 9 GAUGE SIDE AND CROSS
MEMBERS IN EVERY SECOND COURSE (16" O.C.), IN ALL MASONRY WALLS. WALLS
WITH VERTICAL REINFORCING SHALL ONLY HAVE "LADDER" TYPE REINFORCING.
8. ALL REINFORCING BARS, DOWELS AND TIES SHALL CONFORM TO A.S.T.M. A615
GRADE 60. REINFORCING STEEL SHALL BE CONTINUOUS, FABRICATED AND
PLACED IN ACCORDANCE WITH A.C.I. - 315 LATEST EDITION AND HAVE THE
FOLLOWING MINIMUM LAP LENGTHS:
BAR SIZE 8" CMU 12" CMU
#3 18" 18" #4 24" 24" #5 30" 30" #6 38" 36" #7 42"
#8 PROVIDE MECH. SPLICE
9. ALL MASONRY BELOW GRADE SHALL BE GROUTED SOLID.
10. MASONRY GROUT SHALL CONFORM TO ASTM C 476, WITH PEA GRAVEL
AGGREGATE AND A MINIMUM STRENGTH OF 2000 PSI, BUT NOT LESS THAN
SPECIFIED f'm.
11. PROVIDE DOWELS INTO FOUNDATION TO MATCH SIZE AND SPACING OF VERTICAL
REINFORCEMENT AT ALL COLUMNS AND WALLS, UNLESS OTHERWISE NOTED.
2. FLYASH OR GROUND GRANULATED BLAST FURNACE SLAG MAY BE SUBSTITUTED UP TO
25% MAXIMUM OF MIX DESIGN CEMENT CONTENT IN NON-EXPOSED CONCRETE MIXES.
DO NOT USE IN EXPOSED MIX DESIGNS.
SPECIAL INSPECTION
INSPECTION OF FABRICATOR'S (SEC. 1704.2.5) *
FABRICATION AND IMPLEMENTATION PROCEDURES 1704.2.5.1
*SPECIAL INSPECTION IS NOT REQUIRED FOR FABRICATOR SHOP IF CERTIFICATE
OF APPROVAL SUBMITTED BY FABRICATOR'S INSPECTION AGENCY PER
EXCEPTION 1704.2.5.1
1. WORK CONSTRUCTED SHALL BE INSPECTED BY AN INDEPENDENT TESTING
AGENCY TO ENSURE COMPLIANCE WITH THE REQUIREMENTS SHOWN ON THE
DRAWINGS. INSPECTIONS REQUIRED BY CHAPTER 17 OF THE MICHIGAN
BUILDING CODE; LOCAL BUILDING DEPARTMENTS AND THE CONTRACT
DOCUMENTS SHALL BE PERFORMED BY AN INDEPENDENT TESTING AGENCY. SITE
VISITS BY THE DESIGN ENGINEER DO NOT CONSTITUTE OR REPLACE INSPECTION
2. THE FOLLOWING ITEMS SHALL BE INSPECTED IN ACCORDANCE WITH MBC 2021 SEC.
1704 & 1705 BY A CERTIFIED SPECIAL INSPECTOR UNLESS NOTED OTHERWISE IN
REMARKS COLUMN. ALL INSPECTION SHALL BE CONTINUOUS UNLESS
OTHERWISE NOTED. ALL PRODUCTS WITH ICC APPROVALS SHALL BE INSTALLED
PER THE APPROVAL AND PER MANUFACTURER'S RECOMMENDATIONS. FOR
MATERIAL TESTING REQUIREMENTS, SEE SPECIFICATIONS AND/OR GENERAL
NOTES. TESTING AGENCY SHALL SEND COPIES OF ALL STRUCTURAL TESTING AND
INSPECTION REPORTS DIRECTLY TO THE ARCHITECT.
A. PROVIDE 3000 P.S.I. 28-DAY COMPRESSIVE STRENGTH; W/C RATIO, 0.58
MAXIMUM (NON-AIR-ENTRAINED), 5.0 BAG CEMENT MIX FOR ALL FOUNDATION
WORK UNLESS NOTED OTHERWISE.
B. PROVIDE 3500 P.S.I. 28-DAY COMPRESSIVE STRENGTH; W/C RATIO, 0.53
MAXIMUM (NON-AIR-ENTRAINED), 5.5 BAG CEMENT MIX FOR ALL INTERIOR
SLABS UNLESS NOTED OTHERWISE.
C. PROVIDE 4000 P.S.I. 28-DAY COMPRESSIVE STRENGTH; W/C RATIO, 0.45
MAXIMUM (AIR-ENTRAINED), 6.0 BAG CEMENT MIX FOR ALL EXTERIOR
CONCRETE UNLESS NOTED OTHERWISE.
7. PRE-MANUFACTURED ITEMS SUCH AS CANOPIES, AWNINGS, SUNSHADES, ETC.
SHALL BE DESIGNED BY SUPPLIER. SUPPLIER SHALL SUBMIT SIGNED AND SEALED
OF MICHIGAN FOR RECORD TO ARCHITECT. SHOP DRAWINGS SHALL INDICATE ALL
DESIGN LOADS AND INCLUDE ALL CONNECTIONS AND MATERIAL NECESSARY FOR
INSTALLATION OF PRE-MANUFACTURED ITEMS.
SHOP DRAWINGS AND CALCULATIONS BY A REGISTERED ENGINEER IN THE STATE
VERIFICATION AND INSPECTION TASK CONTINUOUS SPECIAL INSPECTION
1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE
ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY.
2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH
AND HAVE REACHED PROPER MATERIAL.
3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED
FILL MATERIALS.
4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT
THICKNESSES DURING PLACEMENT AND COMPACTION OF
X
X
TABLE 1705.6
REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS
COMPACTED FILL.
5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE
AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY.
X
X
X
NOT
APPLICABLE
MINIMUM TESTS
VERIFICATION OF SLUMP FLOW AND VISUAL STABILITY INDEX (VSI) AS DELIVERED
TO THE PROJECT SITE IN ACCORDANCE WITH SPECIFICATION ARTICLE 1.5 B.1.b.3
FOR SELF-CONSOLIDATING GROUT
VERIFICATION OF f' AND f' IN ACCORDANCE WITH SPECIFICATION ARTICLE 1.4B
PRIOR TO CONSTRUCTION, EXCEPT WHERE SPECIFICALLY EXEMPTED BY THIS CODE
ACCm
MINIMUM INSPECTION
CONTINUOUS PERIODIC
INSPECTION TASK
FREQUENCY (a) REFERENCE FOR CRITERIA
NOT
APPLICABLE
TMS 402/ACI
530/ASCE 5
TMS 602/ACI
530.1/ASCE 6
1. VERIFY COMPLIANCE WITH THE APPROVED SUBMITTALS
2. AS MASONRY CONCSTRUCTION BEGINS, VERIFY THAT THE
FOLLOWING ARE IN COMPLIANCE:
a. PROPORTIONS OF SITE-PREPARED MORTAR.
b. CONSTRUCTION OF MORTAR JOINTS.
c. GRADE AND SIZE OF PRESTRESSING TENDONS AND
ANCHORAGES.
d. LOCATION OF REINFORCEMENT, CONNECTORS, PRESTRESSING TENDONS AND ANCHORAGES.
e. PRESTRESSING TECHNIQUE.
f. PROPERTIES OF THIN-BED MORTAR FOR AAC MASONRY
X ART. 1.5
X ART. 2.1, 2.6A
X ART. 3.3B
X
ART. 2.4B,
2.4H
X
ART. 3.4,
3.6A
X ART. 3.6B
X(b) X(c) ART. 2.1C
3. PRIOR TO GROUTING, VERIFY THAT THE FOLLOWING ARE IN
COMPLIANCE:
a. GROUT SPACE
b. GRADE, TYPE AND SIZE OF REINFORCEMENT AND ANCHOR
BOLTS, AND PRESTRESSING TENDONS AND ANCHORAGES
d. PROPORTIONS OF SITE-PREPARED GROUT AND PRESTRESSING
GROUT FOR BONDED TENDONS.
X
ART. 3.2D,
3.2F
X ART. 2.4, 3.4
c. PLACEMENT OF REINFORCEMENT, CONNECTORS, AND
PRESTRESSING TENDONS AND ANCHORAGES
X
ART. 3.2E,
3.4, 3.6A
e. CONSTRUCTION OF MORTAR JOINTS. X ART. 3.3B
4. VERIFY DURING CONSTRUCTION:
a. SIZE AND LOCATION OF STRUCTURAL ELEMENTS
b. TYPE, SIZE, AND LOCATION OF ANCHORS, INCLUDING
OTHER DETAILS OF ANCHORAGE OF MASONRY TO STRUCTURAL
MEMBERS, FRAMES, OR OTHER CONSTRUCTION
c. WELDING OF REINFORCEMENT
SEC. 2.1.7.7.2,
3.3.3.4(c), 8.3.3.4(b), X
d. PREPARATION, CONSTRUCTION, AND PROTECTION OF
MASONRY DURING COLD WEATHER (TEMPERATURE BELOW
40°F (4.4°C) OR HOT WEATHER (TEMPERATURE ABOVE
90°F (32.2°C)
e. APPLICATION AND MEASUREMENT OF PRESTRESSING FORCE
X
ART. 1.8C,
1.8D
X ART. 3.6B
f. PLACEMENT OF GROUT AND PRESTRESSING GROUT FOR
BONDED TENDONS IS IN COMPLIANCE
X ART. 3.5, 3.6C
g. PLACEMENT OF AAC MASONRY UNITS AND CONSTRUCTION
OF THIN-BED MORTAR JOINTS
X ART. 3.3 B.8(b) X(c)
5. OBSERVE PREPARATION OF GROUT SPECIMENS, MORTAR
SPECIMENS, AND/OR PRISMS
ART. 1.4 B.2.a.3,
1.4 B.2.b.3,
1.4 B.2.c.3,
1.4 B.3, 1.4 B.4
X
(a). FREQUENCY REFERS TO THE FREQUENCY OF INSPECTION, WHICH MAY BE CONTINUOUS DURING THE TASK LISTED
OR PERIODICALLY DURING THE LISTED TASK, AS DEFINED IN THE TABLE.
(b). REQUIRED FOR THE FIRST 5000 SQUARE FEET (465 SQUARE METERS) OF ACC MASONRY.
(c). REQUIRED AFTER THE FIRST 5000 SQUARE FEET (465 SQUARE METERS) OF ACC MASONRY.
X ART. 3.3F
X
SEC. 1.16.4.3,
1.17.1
AND INSPECTION OF MASONRY CONSTRUCTION (LEVEL B QUALITY ASSURANCE)
-1. INSPECT REINFORCEMENT, INCLUDING PRESTRESSING
TENDONS, AND VERIFY PLACEMENT.
2. REINFORCING BAR WELDING:
X
X
ACI 318 CH. 20, 25.2,
REFERENCED
AWS D1.4
STANDARD
ACI 318: 26.6.4
1908.4
IBC
REFERENCE
TABLE 1705.3
REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
TYPE
NOT
APPLICABLE
CONTINUOUS
SPECIAL
INSPECTION
PERIODIC
SPECIAL
INSPECTION
a
25.3, 26.6.1-26.6.3
a. VERIFY WELDABILITY OF REINFORCING BARS
OTHER THAN ASTM A706;
b. INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM
5/16" AND
c. INSPECT ALL OTHER WELDS.
- X -x - -
3. INSPECT ANCHORS CAST IN CONCRETE - X ACI 318: 17.8.2- -
4. INSPECT ANCHORS POST-INSTALLED IN HARDENED
X -
CONCRETE MEMBERS.b
a. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY
OR UPWARDLY INCLINED ORIENTATIONS TO RESIST
SUSTAINED TENTION LOADS.
b. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN 4.a.
- X
ACI 318: 17.8.2.4
ACI 318: 17.8.2
5. VERIFY USE OF REQUIRED DESIGN MIX. - X - 1904.1, 1904.2,ACI 318: CH.19.
26.4.3, 26.4.4 1908.2, 1908.3
6. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS
FOR STRENGTH TESTS, PERFORM SLUMP AND AIR
CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF
THE CONCRETE
X - -
ASTM C172
ASTM C31 1908.10
ACI 318: 26.4,26.12
7. INSPECT CONCRETE AND SHOTCRETE PLACEMENT FOR
PROPER APPLICATION TECHNIQUES.
X - - ACI 318: 26.5
1908.6, 1908.7, 2908.8
8. VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE
AND TECHNIQUES.
- X - ACI 318: 26.5.3-26.5.5 1908.9
9. INSPECT PRESTRESSED CONCRETE FOR:
a. APPLICATION OF PRESTRESSING FORCES; AND
b. GROUTING OF BONDED PRESTRESSING TENDONS.
X - -
X - -
ACI 318: 26.10 -
10. INSPECT ERECTION OF PRECAST CONCRETE MEMBERS. - X - ACI 318: CH. 26.8 -
11. VERIFY IN-SITU CONCRETE STRENGTH, PRIOR TO STRESS-
ING OF TENDONS IN POST-TENSIONED CONCRETE AND
PRIOR TO REMOVAL OF SHORES AND FORMS FROM
BEAMS AND STRUCTURAL SLABS.
- X - ACI 318: 26.11.2 -
12. INSPECT FORMWORK FOR SHAPE, LOCATION AND
DIMENSIONS OF THE CONCRETE MEMBER BEING
FORMED.
- X - ACI 318: 26.11.1.2(b) -
FOR SI: 1 INCH = 25.4 MM
a. WHERE APPLICABLE, SEE ALSO SECTION 1705.12, SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE.
b. SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTION SHALL BE INCLUDED IN THE RESEARCH REPORT FOR THE ANCHOR ISSUED BY AN APPROVED SOURCE IN ACCORDANCE WITH 17.8.2 IN ACI 318, OR OTHER QUALIFICATION PROCEDURES. WHERE SPECIFIC REQUIREMENTS ARE NOT PROVIDED, SPECIAL INSPECTION REQUIREMENTS SHALL BE SPECIFIED BY THE REGISTERED DESIGN PROFESSIONAL AND SHALL BE APPROVED BY THE
BUILDING OFFICIAL PRIOR TO THE COMMENCEMENT OF THE WORK.
PERIODIC SPECIAL INSPECTION
REQUIRED VERIFICATION
SPECIAL INSPECTION(CONT.)
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
09/10/2025 BIDS
Livonia Public Schools Central Office Complex Monument Sign
Livonia, Michigan
2025-041
-0
L
PS
-C
EN
TR
AL
O
FF
IC
E
CO
MP
LE
X
MO
NU
ME
NT
S
IG
N
RC
TS
TS
KEY PLAN
hymanski Associates
S T R U C T U R A L E N G I N E E R S
, L.L.C.
Livonia, Michigan 48154 fx.ph.
33426 Five Mile Rd.
S
734.855.4809734.855.4810 email@sastructuralengineers.com
FOUNDATION PLAN
FOUNDATION PLAN
LUMINAIRE SCHEDULE
LAMP
SOURCE
FIXTURE
SYMBOL
FIXTURE
TAG
1. LITHONIA LIGHTING CAT#:
DSXF1 LED P2 40K NSP MVOLT
2. COOPER LIGHTING
3. COLUMBIA
LED
70CRI
LUMENS
FLAG POLE FLOODLIGHT. 3.52"DEEP, 8.86"WIDE, 7.84"HIGH. COLOR
TO BE SELECTED BY ARCHITECT, NARROW SPOT DISTRIBUTION, 5242
LUMENS, ELECTRONIC DRIVER, 4000K. 70CRI, MVOLT.
DESCRIPTION MANUFACTURER(S) WATTS
B
1. LITHONIA LIGHTING CAT#:
DSXF1 LED P2 40K WFR MVOLT
2. COOPER LIGHTING
3. COLUMBIA
LED
70CRI
LUMENS
MONUMENT SIGN FLOODLIGHT. 3.52"DEEP, 8.86"WIDE, 7.84"HIGH.
COLOR TO BE SELECTED BY ARCHITECT, WIDE FLOOD RECTANGULAR
DISTRIBUTION, 3089 LUMENS, ELECTRONIC DRIVER, 4000K. 70CRI,
MVOLT.
A
DESCRIPTION
LIGHTING SYMBOL LIST
SYMBOL
LIGHT FIXTURE - EXTERIOR POLE MOUNT TYPE
TBB
ABBREV.
IG ISOLATED GROUND
TELEPHONE BACKBOARD
ELECTRICAL ABBREVIATIONS
DESCRIPTION
LIGHT FIXTURE - EXTERIOR WALL MOUNT TYPE
LIGHT FIXTURE - CEILING/GRID MOUNT
RP
LP
RECEPTACLE PANEL
LIGHTING PANEL
AF AMPERE FUSE/AMPERE FRAME
WP
(E)
NIC
WEATHERPROOF
NOT IN CONTRACT
RMC
(R)
RIGID METALLIC CONDUIT
RELOCATED EXISTING ELECTRICAL EQUIPMENT
EXISTING ELECTRICAL EQUIPMENT OR WORK
MDP
FACP
ATS
MAIN DISTRIBUTION PANEL
FA
FLA
FIRE ALARM
FULL LOAD AMPS
FIRE ALARM CONTROL PANEL
AUTOMATIC TRANSFER SWITCH
T TRANSFORMER (REFER TO SCHEDULES FOR INFO)
MAIN CIRCUIT BREAKER
MAIN LUG ONLY
AVAILABLE INTERRUPTING CURRENT (AMPS)
NON-FUSIBLENF
MCB
MLO
AIC
GROUND FAULT CIRCUIT INTERRUPTERGFCI/GFI
INDICATED ON PLAN (SHADED AREA INDICATES
EXIT LIGHT - CEILING MOUNTED - ARROWS AS
INDICATED ON PLAN (SHADED AREA INDICATES
EXIT LIGHT - WALL MOUNTED - ARROWS AS
EMERGENCY LIGHT FIXTURE - EMERGENCY BATTERY UNIT
LIGHT FIXTURE - INTERIOR WALL SCONCE
DESCRIPTION
EQUIPMENT DESIGNATION,
DEMOLITION KEY NOTE NUMBER 1
(I.E. EXHAUST FAN NUMBER 1)
CONSTRUCTION KEY NOTE NUMBER 1
SYMBOL
SECTION NUMBER 4
SECTION NO. 6
SECTION
SCALE: 1/4" = 1' - 0"
(ENLARGED PARTIAL PLAN SIMILAR)
DRAWING NOTATION
EXISTING SYSTEM COMPONENT TO BE REMOVED
SHEET E5.2 ON WHICH SECTION IS CUT
SHEET E5.2 ON WHICH
SECTION IS DRAWN
LIGHTING FIXTURE TAG
LIGHT FIXTURE - INTERIOR WALL MOUNTED
TRACK AND TRACK MOUNTED LIGHT FIXTURES
MOTOR - SINGLE PHASE
MOTOR - THREE PHASE
MANUAL DEVICE - PULL STATIONF
METERM
SYMBOL
POWER SYMBOL LIST
DESCRIPTION
FIRE ALARM SYMBOL LIST
SYMBOL DESCRIPTION
FACP FIRE ALARM CONTROL PANEL
DETECTION DEVICE - TAMPER SWITCHTS
DETECTION DEVICE - FLOW SWITCHFS
E5.2
E5.2
NEW OR MODIFIED DEVICES OR EQUIPMENT
EXISTING DEVICES OR EQUIPMENT
LIGHT FIXTURE - EXTERIOR BOLLARD TYPE
FACE(S) OF FIXTURE)
FACE(S) OF FIXTURE)
FD FIRE DEPARTMENT COMMUNICATION OUTLET
LIGHT FIXTURE - INTERIOR WALL MOUNT LINEAR
LIGHT FIXTURE - EXTERIOR POST TOP TYPE
GROUNDG/GRD
LIGHT FIXTURE - DOWNLIGHT WITH WALLWASH DIST.
LIGHT FIXTURE - INTERIOR SURFACE MOUNT
EMERGENCY LIGHT FIXTURE - BATTERY UNIT/EXIT SIGN
AFF ABOVE FINISHED FLOOR
CIRCUIT BREAKERCB
ELECTRICAL METALLIC TUBINGEMT
ELECTRIC WATER COOLEREWC
HAND-OFF-AUTOHOA
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATIONNEMA
POLEP
TYP. TYPICAL
FIRE ALARM ANNUNCIATOR PANELFAA
NEW OR MODIFIED UNDERGROUND WIRING
REMOVE AND REINSTALL(RR)
WG WIRE GUARD
COMMUNICATIONS DEVICE - WALL
PUSH BUTTON
WALL CLOCK - SINGLE FACE
WALL CLOCK AND SPEAKER UNITS
SPEAKERS
CARD READERCR
SYMBOL DESCRIPTION
AUXILIARY SYST. SYMBOL LIST
COMMUNICATIONS DEVICE - FLOOR
WALL CLOCK - DOUBLE FACE
STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS, NFPA 110
YEAR CODE
MICHIGAN BUILDING CODE
MICHIGAN ELECTRICAL CODE RULES, PART 8
LIFE SAFETY CODE, NFPA 101
ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS & FACILITIES
APPLICABLE CODES
AND REGULATIONS
MICHIGAN ENERGY CODE2019
NATIONAL ELECTRICAL CODE (NFPA 70)2023
NATIONAL FIRE ALARM AND SIGNALING CODE, NFPA 722013
NOTES:
1. DRAWINGS INDICATE DESIGN INTENT ONLY, FINAL LOCATIONS AND
DEVICE SPECIFICATIONS SHALL BE PROVIDED BY FIRE ALARM
MANUFACTURER. REFER TO PROJECT SPECIFICATIONS FOR APPROVED
MANUFACTURERS.
DETECTION DEVICE - DUCT MOUNTED
S DETECTION DEVICE
S
NOTIFICATION DEVICE - WALL MOUNTEDF
NOTIFICATION DEVICE - CEILING MOUNTEDF
COMMUNICATIONS DEVICE - 6" ABOVE COUNTER
NOTES:
1. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR BOX AND
CONDUIT FOR ALL DEVICES INDICATED.
2. LOW VOLTAGE CONTRACTOR SHALL PROVIDE EXACT SPECIFICATIONS
AND LOCATIONS OF ALL DEVICES.
CAMERA
MAGNETIC DOOR HOLDERDH
VSD VARIABLE SPEED DRIVE
C CONDUIT OR CEILING MOUNTED
CONDUIT DOWN
CONDUIT UP
CONTACTORC
POWER RECEPTACLE - DUPLEX TYPE
POWER RECEPTACLE - SIMPLEX TYPE
POWER RECEPTACLE - RECESSED FLOOR TYPE
POWER RECEPTACLE - SPECIALTY TYPE
POWER RECEPTACLE - DUPLEX 6" ABOVE COUNTER
POWER RECEPTACLE - QUADRUPLEX TYPE
DISCONNECT SWITCH - NON FUSED
DISCONNECT SWITCH - FUSED
DISCONNECT SWITCH - COMB. MOTOR STARTER
ELECTRICAL PANEL - 208/240 VOLTS
ELECTRICAL PANEL - 480 VOLTS
GROUNDING BAR
GROUND
GROUNDING ROD
JUNCTION BOXJ
J JUNCTION BOX WITH HARDWIRED CONNECTION
MOTOR RATED SWITCHS M
TIME CLOCKTC
SPD SURGE PROTECTION DEVICE
NOTES:
1. ALL DEVICE RATINGS/SIZES SHALL BE COORDINATED WITH PLANS AND
SCHEDULES.
NOTES:
1. LIGHTING SYMBOLS AS INDICATED ON PLANS ARE NOT DRAWN TO
SCALE UNLESS NOTED OTHERWISE.
A AMPERE
AMPERE TRIPAT
AWG AMERICAN WIRE GAUGE
CURRENT TRANSFORMERCT
COPPERCU
DISCONNECTDISC
DIAMETERDIA
EMERGENCY POWER OFFEPO
F FUSE
HORSEPOWERHP
KV KILOVOLT
KVA KILOVOLT AMPERE
KW KILOWATT
KWH KILOWATT HOUR
MAXIMUMMAX
MINIMUMMIN
NATIONAL ELECTRICAL CODENEC
NEUTRALN/NEU
NC NORMALLY CLOSED
NO NORMALLY OPEN
OF/CI OWNER FURNISHED / CONTRACTOR INSTALLED
OF/OI OWNER FURNISHED / OWNER INSTALLED
POWER FACTORPF
PHASEPH. OR Ø
PVC POLYVINYL CHOLRIDE (PLASTIC)
SPEC/SPECS SPECIFICATIONS
UC UNDER COUNTER
UL UNDERWRITERS LABORATORIES
UPS UNINTERRUPTIBLE POWER SUPPLY
VOLT
VA VOLT AMPERE
V
W WATT
XFMR TRANSFORMER
LA
FEEDER SIZE TAG
(REFER TO FEEDER SCHEDULE ON THIS SHEET)
Z1 1A
SCENE SCHEDULE ID 'A'
DAYLIGHTING CONTROL
ZONE '1' (MAY NOT APPEAR ON
EVERY TAG)
LIGHTING CONTROL
SPACE TYPE '1'
LIGHTING CONTROL TAG
POWER RECEPTACLE - USB/DUPLEX COMBO. DEVICEUSB
USB UNIVERSAL SERIAL BUS
LIGHT FIXTURE - INTERIOR PENDANT MOUNT
LIGHT FIXTURE - INTERIOR PENDANT MOUNT CYLINDER
DESCRIPTIONSYMBOL
LIGHTING CONTROLS LEGEND
K SINGLE POLE KEY SWITCH
SWITCH THREE-WAY
SWITCH SINGLE POLE
O OCCUPANCY SENSOR SWITCH
V VACANCY SENSOR SWITCH
VD VACANCY DIMMER SENSOR SWITCH
CEILING MOUNTED OCCUPANCY SENSOR OS
CEILING MOUNTED VACANCY SENSOR VS
D LOW VOLTAGE DIMMER SWITCH
EF-1
VISUAL NOTIFICATION DEVICE - WALL MOUNTED
COMBINATION NOTIFICATION DEVICE - CEILING MOUNTED
F
F
ELECTRICAL GENERAL
INFORMATION
E0.00
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
Livonia Public Schools Central Office Complex Monument Sign
Livonia, Michigan
2025-041
-0
L
PS
-C
EN
TR
AL
O
FF
IC
E
CO
MP
LE
X
MO
NU
ME
NT
S
IG
N
MPH
TJO
TJO
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
UNIFIED BUILDING
SYSTEMS ENGINEERING
UBS PROJECT 029.25.14
69 S. GRATIOT AVE.
MT. CLEMENS, MI 48043
DRAWING INDEX
SHT.
NO. DESCRIPTION
E0.00 ELECTRICAL GENERAL INFORMATION
ESD1.00 ELECTRICAL SITE DEMOLITION PLAN
ES1.00 ELECTRICAL SITE NEW WORK PLAN
E5.00 ELECTRICAL DETAILS
09/10/2025 BIDS
X
(E)LP-A2
(E)TIMER
GENERAL DEMOLITION NOTES
A
THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL
EXTENT OF WORK TO BE PERFORMED. THE EXACT EXTENT OF
DEMOLITION SHALL BE DETERMINED BY THE NEW WORK.
B
ANY INTERRUPTIONS OF EXISTING SERVICES AND/OR EQUIPMENT SHALL
BE PERFORMED AT A TIME APPROVED IN ADVANCE BY OWNER'S
REPRESENTATIVE SO AS NOT TO INTERFERE WITH THE PRESENT
BUILDING'S OPERATION.
C
PRIOR TO COMMENCEMENT OF WORK, CONTRACTOR SHALL VISIT THE
SITE AND BECOME FAMILIAR WITH EXISTING SITE CONDITIONS,
SYSTEMS, AND UTILITIES. NOTIFY DESIGN PROFESSIONAL OF ANY
INTERFERENCES OR DISCREPANCIES.
D
ALL ITEMS INDICATED WITH CROSS-HATCHING SHALL BE REMOVED
COMPLETELY WITH ALL RELATED ITEMS INCLUDING HANGERS,
SUPPORTS, INSULATION, CONTROLS, ETC. CAP ALL OPEN-ENDED PIPES
AND DUCTS.
E
THE OWNER SHALL HAVE FIRST RIGHT OF REFUSAL ON ALL EQUIPMENT
BEING REMOVED. ALL ITEMS REMOVED SHALL BE LEGALLY DISPOSED OF.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXISTING
RELOCATED AND OWNER-PROVIDED EQUIPMENT.
F
VERIFY DEPTH, SIZE, LOCATIONS, AND CONDITIONS OF EXISTING
UTILITIES IN THE FIELD. INCLUDING POINTS OF CONNECTION PRIOR TO
STARTING WORK.
G
ALL ITEMS ON DEMOLITION PLAN SHALL BE CONSIDERED EXISTING
UNLESS OTHERWISE NOTED. ALL WORK INDICATED ON PLANS HAS BEEN
LOCATED PER EXISTING DRAWINGS AND/OR FIELD OBSERVATION AND
REQUIRES FIELD VERIFICATION.
H
ALL EXISTING WORK TO REMAIN SHALL BE PROTECTED FROM DAMAGE.
WHERE DUCT WORK PIPE INSULATION HAS BEEN DAMAGED DURING
DEMOLITION, THE CONTRACTOR SHALL REPAIR INSULATION AS
REQUIRED TO MATCH EXISTING.
DEMOLITION KEYED NOTES
SIGN BEING REMOVED COMPLETE BY OTHERS. ELECTRICAL CONTRACTOR
SHALL DISCONNECT AND MAKE SAFE. PROTECT CONDUIT AND WIRING.
PREPARE TO RE-USE CIRCUIT. REFER TO NEW WORK PLANS FOR
FURTHER INFORMATION.
JUNCTION BOX AND ALL ASSOCIATED COMPONENTS SHALL BE REMOVED
COMPLETE. DISCONNECT ALL CIRCUITS AND MAKE SAFE. PROTECT
CONDUIT AND WIRING AND PREPARE TO RE-WORK CONDUIT AND
INSTALL NEW JUNCTION BOX. REFER TO NEW WORK PLANS FOR
FURTHER INFORMATION.
3 FLAG POLE LIGHT AND ALL ASSOCIATED COMPONENTS SHALL BE
REMOVED COMPLETE.
X
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
Livonia Public Schools Central Office Complex Monument Sign
Livonia, Michigan
2025-041
-0
L
PS
-C
EN
TR
AL
O
FF
IC
E
CO
MP
LE
X
MO
NU
ME
NT
S
IG
N
MPH
TJO
TJO
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
UNIFIED BUILDING
SYSTEMS ENGINEERING
UBS PROJECT 029.25.14
69 S. GRATIOT AVE.
MT. CLEMENS, MI 48043
ELECTRICAL SITE
DEMOLITION PLAN
ESD1.00
SCALE:
ELECTRICAL SITE DEMOLITION PLAN
1/16" = 1'-0"
X
(E)LP-A2
(E)TIMER
A
A
B
B
3 2
SITE PLAN GENERAL NOTES
A
FIELD VERIFY LOCATIONS OF EXISTING UNDERGROUND SERVICES TO
COORDINATE ALL POLE BASE LOCATIONS AND UNDERGROUND SERVICES
BEING INSTALLED UNDER THIS CONTRACT WITH CIVIL DRAWINGS PRIOR
TO INSTALLATION OF POLE BASES AND CONDUIT.
B
ALL THREE PHASE WIRES, NEUTRAL, AND GROUND SHALL BE RUN TO
LAST LIGHTING FIXTURE AND CAPPED FOR FUTURE EXPANSION.
C
ANY 120 VOLT BRANCH CIRCUIT FEEDER LONGER THAN 75'-0" TO LAST
DEVICE SHALL BE SIZED TO THE NEXT LARGER STANDARD AWG SIZE. E.C.
SHALL FIELD VERIFY ALL LENGTHS OF FEEDERS.
D ALL ELECTRICAL DEVICES ON THIS SHEET SHALL BE NEW UNLESS
OTHERWISE NOTED.
NEW WORK KEYED NOTES
PROVIDE NEW 12"H X 12"W X 6"D WEATHERPROOF JUNCTION BOX WITH
BACK PLATE AND REMOVABLE FRONT COVER. JUNCTION BOX IS TO BE
SURFACE MOUNTED TO THE MASONRY BASE OF THE SIGN. REWORK
EXISTING TO REMAIN CONDUIT AND WIRING AS REQUIRED. REMOVE ALL
EXISTING FLEXIBLE CONDUIT AND REPLACE WITH PVC CONDUIT. REFER
TO ELECTRICAL DETAILS FOR FURTHER INFORMATION.
GROUND MOUNTED LIGHT FOR MONUMENT SIGN. RE-USE A CIRCUIT AS
A RESULT OF DEMOLITION WORK. UPDATE PANEL SCHEDULE. REFER TO
LUMINAIRE SCHEDULE FOR FIXTURE TYPE. REFER TO ELECTRICAL
DETAILS FOR FURTHER INFORMATION ON INSTALLATION AND
MOUNTING.
GROUND MOUNTED LIGHT FOR FLAG POLE. RE-USE A CIRCUIT AS A
RESULT OF DEMOLITION WORK. UPDATE PANEL SCHEDULE. REFER TO
LUMINAIRE SCHEDULE FOR FIXTURE TYPE. REFER TO ELECTRICAL
DETAILS FOR FURTHER INFORMATION ON INSTALLATION AND
MOUNTING.
X
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
Livonia Public Schools Central Office Complex Monument Sign
Livonia, Michigan
2025-041
-0
L
PS
-C
EN
TR
AL
O
FF
IC
E
CO
MP
LE
X
MO
NU
ME
NT
S
IG
N
MPH
TJO
TJO
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
UNIFIED BUILDING
SYSTEMS ENGINEERING
UBS PROJECT 029.25.14
69 S. GRATIOT AVE.
MT. CLEMENS, MI 48043
ELECTRICAL SITE NEW
WORK PLAN
ES1.00
SCALE:
ELECTRICAL SITE NEW WORK PLAN
1/16" = 1'-0"
0'-6"
FLOOD LIGHTING BASE DETAIL
NO SCALE
REINFORCED ROUND
CONCRETE BASE
(3)#4 WITH #3 TIES
AT 12" O.C.
CONDUIT COUPLING
SCHED. 40 PVC
ENCASE STANCHION IN
CONCRETE BASE OVER
TOP OF CONDUITS
FINISH GRADE
CHAMFER
FLOOD LIGHT HOUSING
ADJUSTABLE KNUCKLE AND
ACCESS COVER CONNECTION
4"
3'-6" DEPTH MINIMUM
12" ROUND
C
(E)INTERMATIC 24-HOUR DIGITAL TIMER
(LOCATED IN BASEMENT NEXT TO PANEL LP-A2)
LIGHTING CONTACTOR
SQUARE D MODEL 8910DPA34V02 OR EQUIVALENT
120VAC COIL, (4) N.O. 575VAC RATED CONTACTS
LP-A2-19
SEQUENCE OF OPERATION:
NORMAL CONDITIONS - UNDER NORMAL CONDITIONS, THE CONTACTOR COIL IS DE-ENERGIZED AND
THE CONTACTS ARE OPEN. THE LIGHTS ARE NOT ON.
ACTIVATION - UPON THE INTERMATIC 24-HOUR DIGITAL TIMER ACTIVATING THE CONTACTOR COIL ENERGIZES AND ALL OF THE ASSOCIATED CONTACTS IN THE CONTACTOR ARE CLOSED TURNING THE
LIGHTS ON.
CONTACT STATUS IS SHOWN
WITH THE COIL DE-ENERGIZED (TYPICAL)
T1
T2
T3
LIGHTING CONTACTOR
NO SCALE
T4L4
L3
L2
L1
T
LP-A2-X
LP-A2-X
LP-A2-X
LP-A2-X (E) POLE LIGHTS
MONUMENT SIGN GROUND LIGHTS
FLAG POLE GROUND LIGHTS
SPARE
JUNCTION BOX BACK PLATE DETAIL
NO SCALE
LIGHTING CONTACTORFUSE HOLDER
BUSSMANN BMM603-1SQ OR EQUIVELANT
WITH FUSES AND SAFTEY PULLER
(E)CIRCUITS FROM LP-A2 LOAD WIRING
12"H X 12"W X 6"D SURFACE MOUNTED WEATHERPROOF
JUNCTION BOX WITH REMOVEABLE COVER
GRADE LINE
12"H X 12"W X 6"D SURFACE MOUNTED WEATHERPROOF
JUNCTION BOX WITH REMOVEABLE COVER
GRADE LINE
CONDUITS
54" 54"
MONUMENT SIGN BACK DETAIL
NO SCALE
MONUMENT SIGN SIDE DETAIL
NO SCALE
FLAG POLE DETAIL
NO SCALE
30"
30"
FLAG POLE
ELECTRICAL DETAILS
E5.00
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
Livonia Public Schools Central Office Complex Monument Sign
Livonia, Michigan
2025-041
-0
L
PS
-C
EN
TR
AL
O
FF
IC
E
CO
MP
LE
X
MO
NU
ME
NT
S
IG
N
MPH
TJO
TJO
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
UNIFIED BUILDING
SYSTEMS ENGINEERING
UBS PROJECT 029.25.14
69 S. GRATIOT AVE.
MT. CLEMENS, MI 48043
| 25041 A000 |
| A000 |
| 25041 A001 |
| A001 |
| 25041A100 |
| A100 |
| 25041 A101 |
| A1.01 |
| A002 |
| A000 |
| A001 |
| A002 |
| AD200 |
| A100 |
| A101 |