2506 Commissioning RFP_Exhibit A_Phase A Drawings_Part2.pdf

PDF 31 MB Posted

Attached to
RFP-905 ENGR KSU Health Sciences Cntr Cx Auth, Frankfort, KY
Solicitation number
RFP 785 2700000030 3
Issued by
Elliott County, Kentucky

About this file

This is a Phase A plumbing design drawing document for the Kentucky State University (KSU) Health Science Center Commissioning project located in Frankfort, Kentucky, prepared by Kohrs Lonnemann Heil Engineers, Inc. The drawings specify comprehensive plumbing system details including domestic cold water (C1.6), domestic hot water (H1.6), hot water return (HR1.6), sanitary (S1.19, S1.2), indirect waste (S9.3), and vent (V1.2) piping systems utilizing copper Type L (ASTM B88), PVC Schedule 40 (ASTM D1785/D2665), and cast iron hubless (ASTM A888) materials. The document contains multiple detailed specifications for casework sink coordination, pipe penetrations through walls and foundations, pipe hanger installations, roof drain insulation, elevator sump pit configurations, water hammer arrestor placement, eyewash and shower stations, floor drains with trap seals, cleanout details, beverage equipment backflow preventers, thermostatic mixing valves, roof hydrants, and mop sink installations. The drawings are organized into plumbing details (P-501, P-502), enlarged plans (P-741) covering underground and above-ground levels including restrooms and janitor storage areas, and isometric diagrams (P-901, P-902) showing sanitary and vent system configurations.

The document emphasizes critical coordination requirements between the plumbing contractor, casework provider, architect, owner, and engineer of record prior to product submittal and purchase order finalization. All sink bowl and faucet dimensions must be coordinated to ensure proper fit and complete installation, with sample submittals or schematic drawings required. Immediate notification to the engineer of record is mandated if any conflicts arise between sink bowl, faucet, and casework components. The specifications require ASSE-rated backflow preventers, water hammer arrestors compliant with ASSE 1010 or PDI-WH 201 standards, and proper insulation of drainage piping offsets. Additional requirements include thermostatic mixing valves set at 85°F for eyewash stations with 36-inch rim height, trap primer lines not exceeding 20 feet, and medical gas zone valve box installation coordinated with architectural elevations per NFPA 99 standards.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1. COORDINATE FAUCET SPOUT REACH

WITH OWNER REQUIREMENTS.

2. COORDINATE SINK LENGTH, WIDTH ,

AND DEPTH WITH CASEWORK

PROVIDER TO ENSURE CORRECT FIT

AND COMPLETE INSTALLATION.

3. COORDINATE SINK DRAIN OFFSET

WITH CASEWORK PROVIDER TO

ENSURE CORRECT FIT AND COMPLETE

INSTALLATION.

4. COORDINATE FAUCET SPREAD AND,

NUMBER OF HOLES TO

ACCOMMODATE FAUCET

INSTALLATION.

5. COORDINATE NUMBER OF HOLES AND

LOCATION OF ADDITONAL SINK

ACCESSORIES.

6. COORDINATE SINK P-TRAP AND/OR

FOOD DISPOSER LOCATION WITH

CASEWORK PROVIDER TO ENSURE

CORRECT FIT AND COMPLETE

INSTALLATION.

KEYED NOTES:

FRONT ELEVATION SIDE ELEVATION

PLAN VIEW

GENERAL NOTES:

A. ALL SINK BOWL AND FAUCET DIMENSIONS AND PHYSICAL

CHARACTERISTICS SHALL BE COORDINATED WITH OWNER,

ARCHITECT, AND CASEWORK PROVIDER PRIOR TO PRODUCT

SUBMITTAL AND FINALIZING PURCHASE ORDER.

B. PROVIDE A SAMPLES OR SCHEMATIC DRAWINGS OF SINK BOWL

AND FAUCET INSTALLATION COORDINATED WITH CASEWORK

AND ARCHITECTURAL ELEMENTS AS NECESSARY TO ENSURE A

COMPLETE INSTALLATION PRIOR TO FINALIZING PURCHASE

ORDER.

C. IF ANY CONFLICT BETWEEN SINK BOWL, FAUCET, AND/OR

CASEWORK ARISE IMMEDIATELY NOTIFY ENGINEER OF RECORD

PRIOR TO PURCHASING AND INSTALLATION.

KEYED NOTES:

1. PIPE.

2. SCHEDULE 40 STEEL PIPE SLEEVE TO BE

1" LARGER THAN THE OUTSIDE

SURFACE OF PIPE INSULATION AND

FLUSH TO WALL SURFACE. DO NOT

SUPPORT PIPING WITH SLEEVE.

3. FLEXIBLE SEALANT OR FIRE RATED

SEALANT FOR FIRE RATED

PENETRATIONS.

4. ESCUTCHEON PLATE TO COMPLETELY

COVER OPENING.

5. FINISHED WALL SURFACE. REFER TO

ARCHITECTURAL PLANS FOR WALL

CONSTRUCTION TYPE.

KEYED NOTES:

1. NON-COMBUSTIBLE PIPE.

2. PIPE INSULATION TO BE CONTINUOUS

THROUGH WALL.

3. FLEXIBLE SEALANT OR FIRE RATED

SEALANT FOR FIRE RATED PENETRATIONS.

4. SCHEDULE 40 STEEL PIPE SLEEVE TO BE 1"

LARGER THAN THE OUTSIDE SURFACE OF

PIPE INSULATION AND FLUSH TO WALL

SURFACE. DO NOT SUPPORT PIPING WITH

SLEEVE.

5. FINISHED WALL SURFACE. REFER TO

ARCHITECTURAL PLANS FOR WALL

CONSTRUCTION TYPE.

KEYED NOTES:

PIPE PENETRATION FROM AN UNEXCAVATED TO

EXCAVATED SOIL CONDITION

1. MODULAR MECHANICAL PIPE SEAL.

2. CAST-IN-PLACE STEEL SLEEVE WITH

ANCHORING FLANGE (2 NOMINAL PIPES

SIZES LARGER). FLUSH SLEEVE END

WITH INTERIOR WALL SURFACE.

3. EXTEND SLEEVE TO ALLOW PROPER

CONNECTION TO REDUCER COUPLING.

4. PIPE CENTERED IN SLEEVE

5. FLEXIBLE REDUCER COUPLING.

6. CONCRETE WALL/FOUNDATION.

6UNEXCAVATED SOIL

UNEXCAVATED SOIL

EXCAVATED SOIL

EXCAVATED SOIL

GENERAL NOTES:

1. REFER TO STRUCTURAL

DRAWINGS FOR PENETRATION

REQUIREMENTS THROUGH

STRUCTURAL MEMBERS.

KEYED NOTES:

1. PIPE.

2. PIPE INSULATION.

3. FLEXIBLE SEALANT OR FIRE RATED

SEALANT FOR FIRE RATED

PENETRATIONS.

4. SCHEDULE 40 STEEL PIPE SLEEVE TO BE

1" LARGER THAN THE OUTSIDE

SURFACE OF PIPE INSULATION AND

FLUSH TO WALL SURFACE. DO NOT

SUPPORT PIPING WITH SLEEVE.

5. RISER CLAMP.

6. FINISHED FLOOR. REFER TO

ARCHITECTURAL PLANS FOR FLOOR

CONSTRUCTION TYPE.

5 3

KEYED NOTES:

1. METAL UNISTRUT.

2. NUT AND WASHER.

3. UNISTRUT BEAM CLAMP.

4. HANGER ROD.

5. SIDE BEAM CLAMP.

6. C-CLAMP FOR PIPING.

7. STRUCTURAL STEEL. I-

BEAM OR OPEN WEB

STEEL JOIST.

2 1

KEYED NOTES:

1. HANGER ROD.

2. GALVANIZED STEEL PIPE SHIELD AND 360° CALCIUM SILICATE

INSULATION HANGER SUPPORT.

3. PIPE INSULATION.

4. PIPE.

5. UNISTRUT CHANNEL.

6. CLEVIS HANGER.

7. TRAPEZE PIPE HANGER.

KEYED NOTES:

1. OVERFLOW DRAIN.

2. PRIMARY ROOF DRAIN.

3. ROOF. REFER TO STRUCTURAL AND

ARCHITECTURAL PLANS FOR

CONSTRUCTION.

4. INSULATE DRAIN BODY.

5. PIPE HANGER.

6. GALVANIZED STEEL PIPE SHIELD AND

360° CALCIUM SILICATE INSULATION

HANGER SUPPORT.

7. PIPE INSULATION.

8. INSULATE ELBOW. UNINSULATED

VERTICAL DROP.

1 2

1. HIGH WATER ALARM PANEL.

2. LOCAL DISCONECT. DEDICATED CIRCUIT.

3. DISCHARGE PIPING.

4. SHUT-OFF VALVE.

5. COUPLINGS.

6. CHECK VALVE.

7. HIGH WATER SWITCH.

8. ELEVATOR SUMP. MINIMUM OF 24" x 24" x 36".

9. AUTOMATIC EFFLUENT PUMP.

KEYED NOTES:

NOTES:

• ALARM PANEL AND PUMP SHALL BE CONNECTED TO DIFFERENT ELECTRICAL CIRCUITS.

• COORDINATE PIPE ROUTING WITH ELEVATOR CONTRACTOR.

• IF LOCATION OF REMOTE ALARM PANEL CORD DISTANCE EXCEEDS MANUFACTURERS

RECOMMENDED LENGTH, CONTACT ENGINEER OF RECORD PRIOR TO INSTALLING THE

EQUIPMENT.

EWH1

EWH2

ET1

CP1

CP1

HPT1

DBP1

4" C1.6

4" C1.6

1 1/2" C1.6

RTA DATE

DRAWN BY

CHECKED BY

A & E FILE NO

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING & CONTRACT ADMINISTRATION

FRANKFORT, KENTUCKY

AS BUILT DATE

DECA LOG #

ACCOUNT NO.

DRAWING NO.

DESCRIPTION OF REVISIONS DATE

DRAWING DATE

PHASE

REVISION HISTORY OF THIS DRAWING

DESCRIPTION OF REVISIONS DATE

DRAWING INFORMATION

435-CBQA-KS64-00

A

1538 ALEXANDRIA PIKE,

SUITE 11

FT. THOMAS, KENTUCKY

41075 859-442-8050

WWW.KLHENGRS.COM

O W

N E

R S

H

IP

O F

I N

S T

R U

M E

N T

S O

F S

E R

V

IC

E

A ll re p o rt s p la n s s p e c ifi c a tio n s c o m p u te r fil e s fie ld d a ta n o te s a n d o th e r d o c u m e n ts a n d in s tr u m e n ts p re p a re d b y t h e C o n s u lt a n t a s in s tr u m e n ts o f s e rv ic e s h a ll re m a in t h e p ro p e rt y o f th e C o n s u lt a n t.

T h e C o n s u lt a n t s h a ll re ta in a ll c o m m o n l a w s ta tu to ry a n d o th e r re s e rv e d ri g h ts in c lu d in g w ith o u t lim ita tio n th e c o p y ri g h t th e re to

KOHRS LONNEMANN HEIL

ENGINEERS, INC.

KFE

DMR

P-501

PLUMBING DETAILS05/15/26

R25092.00

KSU - HEALTH SCIENCE CENTER

KLH PROJECT # 27734

SCALE: NONE

220000.00-04 - CASEWORK SINK COORDINATION DETAIL

SCALE: NONE

220517.00-03 - PIPE PENETRATION WITHOUT INSULATION

SCALE: NONE

220517.00-02 - INTERIOR WALL PENETRATION

SCALE: NONE

220517.00-05 - BELOWGRADE PIPE PENETRATION THROUGH A FOUNDATION

WALL

SCALE: NONE

220517.00-04 - PIPE SLEEVE THROUGH EXPOSED FLOOR

SCALE: NONE

220529.00-02 - TYPICAL METHODS OF SECURING HANGER RODS TO

STRUCTURAL STEEL

SCALE: NONE

220529.00-01 - PLUMBING PIPE HANGER INSTALLATION

SCALE: NONE

221123.00-01 - HOT WATER RECIRCULATION PUMP

SCALE: NONE

223300.00-03 - WATER HEATER DETAIL

SCALE: NONE

220719.00-02 - INSULATION OF STORM DRAINAGE PIPING OFFSETS

SCALE: NONE

223004.00-06 - ELEVATOR SUMP PIT DETAIL

SCALE: NONE

221123.13-01 - DOMESTIC BOOSTER PUMP DETAIL

Pipe Type Legend

Mark Color System Name Pipe Material

C1.6

H1.6

HR1.6

S9.3

C1 - Domestic Cold Water

H1 - Domestic Hot Water

HR1 - Hot Water Return

S9 - Indirect Waste

6 - Copper - Type L - ASTM B88

6 - Copper - Type L - ASTM B88

6 - Copper - Type L - ASTM B88

3 - Copper - DWV - ASTM B306

1. COORDINATE FAUCET SPOUT REACH

WITH OWNER REQUIREMENTS.

2. COORDINATE SINK LENGTH, WIDTH ,

AND DEPTH WITH CASEWORK

PROVIDER TO ENSURE CORRECT FIT

AND COMPLETE INSTALLATION.

3. COORDINATE SINK DRAIN OFFSET

WITH CASEWORK PROVIDER TO

ENSURE CORRECT FIT AND COMPLETE

INSTALLATION.

4. COORDINATE FAUCET SPREAD AND,

NUMBER OF HOLES TO

ACCOMMODATE FAUCET

INSTALLATION.

5. COORDINATE NUMBER OF HOLES AND

LOCATION OF ADDITONAL SINK

ACCESSORIES.

6. COORDINATE SINK P-TRAP AND/OR

FOOD DISPOSER LOCATION WITH

CASEWORK PROVIDER TO ENSURE

CORRECT FIT AND COMPLETE

INSTALLATION.

KEYED NOTES:

FRONT ELEVATION SIDE ELEVATION

PLAN VIEW

GENERAL NOTES:

A. ALL SINK BOWL AND FAUCET DIMENSIONS AND PHYSICAL

CHARACTERISTICS SHALL BE COORDINATED WITH OWNER,

ARCHITECT, AND CASEWORK PROVIDER PRIOR TO PRODUCT

SUBMITTAL AND FINALIZING PURCHASE ORDER.

B. PROVIDE A SAMPLES OR SCHEMATIC DRAWINGS OF SINK BOWL

AND FAUCET INSTALLATION COORDINATED WITH CASEWORK

AND ARCHITECTURAL ELEMENTS AS NECESSARY TO ENSURE A

COMPLETE INSTALLATION PRIOR TO FINALIZING PURCHASE

ORDER.

C. IF ANY CONFLICT BETWEEN SINK BOWL, FAUCET, AND/OR

CASEWORK ARISE IMMEDIATELY NOTIFY ENGINEER OF RECORD

PRIOR TO PURCHASING AND INSTALLATION.

KEYED NOTES:

1. PIPE.

2. SCHEDULE 40 STEEL PIPE SLEEVE TO BE

1" LARGER THAN THE OUTSIDE

SURFACE OF PIPE INSULATION AND

FLUSH TO WALL SURFACE. DO NOT

SUPPORT PIPING WITH SLEEVE.

3. FLEXIBLE SEALANT OR FIRE RATED

SEALANT FOR FIRE RATED

PENETRATIONS.

4. ESCUTCHEON PLATE TO COMPLETELY

COVER OPENING.

5. FINISHED WALL SURFACE. REFER TO

ARCHITECTURAL PLANS FOR WALL

CONSTRUCTION TYPE.

KEYED NOTES:

1. NON-COMBUSTIBLE PIPE.

2. PIPE INSULATION TO BE CONTINUOUS

THROUGH WALL.

3. FLEXIBLE SEALANT OR FIRE RATED

SEALANT FOR FIRE RATED PENETRATIONS.

4. SCHEDULE 40 STEEL PIPE SLEEVE TO BE 1"

LARGER THAN THE OUTSIDE SURFACE OF

PIPE INSULATION AND FLUSH TO WALL

SURFACE. DO NOT SUPPORT PIPING WITH

SLEEVE.

5. FINISHED WALL SURFACE. REFER TO

ARCHITECTURAL PLANS FOR WALL

CONSTRUCTION TYPE.

KEYED NOTES:

PIPE PENETRATION FROM AN UNEXCAVATED TO

EXCAVATED SOIL CONDITION

1. MODULAR MECHANICAL PIPE SEAL.

2. CAST-IN-PLACE STEEL SLEEVE WITH

ANCHORING FLANGE (2 NOMINAL PIPES

SIZES LARGER). FLUSH SLEEVE END

WITH INTERIOR WALL SURFACE.

3. EXTEND SLEEVE TO ALLOW PROPER

CONNECTION TO REDUCER COUPLING.

4. PIPE CENTERED IN SLEEVE

5. FLEXIBLE REDUCER COUPLING.

6. CONCRETE WALL/FOUNDATION.

6UNEXCAVATED SOIL

UNEXCAVATED SOIL

EXCAVATED SOIL

EXCAVATED SOIL

GENERAL NOTES:

1. REFER TO STRUCTURAL

DRAWINGS FOR PENETRATION

REQUIREMENTS THROUGH

STRUCTURAL MEMBERS.

KEYED NOTES:

1. PIPE.

2. PIPE INSULATION.

3. FLEXIBLE SEALANT OR FIRE RATED

SEALANT FOR FIRE RATED

PENETRATIONS.

4. SCHEDULE 40 STEEL PIPE SLEEVE TO BE

1" LARGER THAN THE OUTSIDE

SURFACE OF PIPE INSULATION AND

FLUSH TO WALL SURFACE. DO NOT

SUPPORT PIPING WITH SLEEVE.

5. RISER CLAMP.

6. FINISHED FLOOR. REFER TO

ARCHITECTURAL PLANS FOR FLOOR

CONSTRUCTION TYPE.

5 3

KEYED NOTES:

1. METAL UNISTRUT.

2. NUT AND WASHER.

3. UNISTRUT BEAM CLAMP.

4. HANGER ROD.

5. SIDE BEAM CLAMP.

6. C-CLAMP FOR PIPING.

7. STRUCTURAL STEEL. I-

BEAM OR OPEN WEB

STEEL JOIST.

2 1

KEYED NOTES:

1. HANGER ROD.

2. GALVANIZED STEEL PIPE SHIELD AND 360° CALCIUM SILICATE

INSULATION HANGER SUPPORT.

3. PIPE INSULATION.

4. PIPE.

5. UNISTRUT CHANNEL.

6. CLEVIS HANGER.

7. TRAPEZE PIPE HANGER.

KEYED NOTES:

1. OVERFLOW DRAIN.

2. PRIMARY ROOF DRAIN.

3. ROOF. REFER TO STRUCTURAL AND

ARCHITECTURAL PLANS FOR

CONSTRUCTION.

4. INSULATE DRAIN BODY.

5. PIPE HANGER.

6. GALVANIZED STEEL PIPE SHIELD AND

360° CALCIUM SILICATE INSULATION

HANGER SUPPORT.

7. PIPE INSULATION.

8. INSULATE ELBOW. UNINSULATED

VERTICAL DROP.

1 2

1. HIGH WATER ALARM PANEL.

2. LOCAL DISCONECT. DEDICATED CIRCUIT.

3. DISCHARGE PIPING.

4. SHUT-OFF VALVE.

5. COUPLINGS.

6. CHECK VALVE.

7. HIGH WATER SWITCH.

8. ELEVATOR SUMP. MINIMUM OF 24" x 24" x 36".

9. AUTOMATIC EFFLUENT PUMP.

KEYED NOTES:

NOTES:

• ALARM PANEL AND PUMP SHALL BE CONNECTED TO DIFFERENT ELECTRICAL CIRCUITS.

• COORDINATE PIPE ROUTING WITH ELEVATOR CONTRACTOR.

• IF LOCATION OF REMOTE ALARM PANEL CORD DISTANCE EXCEEDS MANUFACTURERS

RECOMMENDED LENGTH, CONTACT ENGINEER OF RECORD PRIOR TO INSTALLING THE

EQUIPMENT.

EWH1

EWH2

ET1

CP1

CP1

HPT1

DBP1

4" C1.6

4" C1.6

1 1/2" C1.6

RTA DATE

DRAWN BY

CHECKED BY

A & E FILE NO

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING & CONTRACT ADMINISTRATION

FRANKFORT, KENTUCKY

AS BUILT DATE

DECA LOG #

ACCOUNT NO.

DRAWING NO.

DESCRIPTION OF REVISIONS DATE

DRAWING DATE

PHASE

REVISION HISTORY OF THIS DRAWING

DESCRIPTION OF REVISIONS DATE

DRAWING INFORMATION

435-CBQA-KS64-00

A

1538 ALEXANDRIA PIKE,

SUITE 11

FT. THOMAS, KENTUCKY

41075 859-442-8050

WWW.KLHENGRS.COM

O W

N E

R S

H

IP

O F

I N

S T

R U

M E

N T

S O

F S

E R

V

IC

E

A ll re p o rt s p la n s s p e c ifi c a tio n s c o m p u te r fil e s fie ld d a ta n o te s a n d o th e r d o c u m e n ts a n d in s tr u m e n ts p re p a re d b y t h e C o n s u lt a n t a s in s tr u m e n ts o f s e rv ic e s h a ll re m a in t h e p ro p e rt y o f th e C o n s u lt a n t.

T h e C o n s u lt a n t s h a ll re ta in a ll c o m m o n l a w s ta tu to ry a n d o th e r re s e rv e d ri g h ts in c lu d in g w ith o u t lim ita tio n th e c o p y ri g h t th e re to

KOHRS LONNEMANN HEIL

ENGINEERS, INC.

KFE

DMR

P-501

PLUMBING DETAILS05/15/26

R25092.00

KSU - HEALTH SCIENCE CENTER

KLH PROJECT # 27734

SCALE: NONE

220000.00-04 - CASEWORK SINK COORDINATION DETAIL

SCALE: NONE

220517.00-03 - PIPE PENETRATION WITHOUT INSULATION

SCALE: NONE

220517.00-02 - INTERIOR WALL PENETRATION

SCALE: NONE

220517.00-05 - BELOWGRADE PIPE PENETRATION THROUGH A FOUNDATION

WALL

SCALE: NONE

220517.00-04 - PIPE SLEEVE THROUGH EXPOSED FLOOR

SCALE: NONE

220529.00-02 - TYPICAL METHODS OF SECURING HANGER RODS TO

STRUCTURAL STEEL

SCALE: NONE

220529.00-01 - PLUMBING PIPE HANGER INSTALLATION

SCALE: NONE

221123.00-01 - HOT WATER RECIRCULATION PUMP

SCALE: NONE

223300.00-03 - WATER HEATER DETAIL

SCALE: NONE

220719.00-02 - INSULATION OF STORM DRAINAGE PIPING OFFSETS

SCALE: NONE

223004.00-06 - ELEVATOR SUMP PIT DETAIL

SCALE: NONE

221123.13-01 - DOMESTIC BOOSTER PUMP DETAIL

Pipe Type Legend

Mark Color System Name Pipe Material

C1.6

H1.6

HR1.6

S9.3

C1 - Domestic Cold Water

H1 - Domestic Hot Water

HR1 - Hot Water Return

S9 - Indirect Waste

6 - Copper - Type L - ASTM B88

6 - Copper - Type L - ASTM B88

6 - Copper - Type L - ASTM B88

3 - Copper - DWV - ASTM B306

KEYED NOTES:

1. 3" MINIMUM VENT TEMINAL TO BE

A MINIMUM OF 1'-0" OR 6" ABOVE

LOCAL SNOW LEVELS. CONSULT

LOCAL CODES IF THEY VARY

FROM THIS STANDARD.

2. PIPE SEALANT. COORDINATE

SEALANT TYPE WITH ROOFING

CONTRACTOR.

3. STAINLESS STEEL PIPE CLAMP.

4. VENT FLASHING. COORDINATE

FLASHING MATERIAL AND

INSTALLATION WITH ROOFING

CONTRACTOR.

5. ROOFING SYSTEM.

6. THERMAL ENVOLOPE

INSULATION.

7. ANY CHANGE IN VENT SIZE SHALL

BE MADE NOT LESS THAN 1'-0"

INSIDE THE THERMAL ENVELOPE.

1'-0" MINIMUM

1'-0" MINIMUM

KEYED NOTES:

1. HORIZONTAL OR VERTICAL HOT OR COLD

WATER MAIN.

2. WATER HAMMER ARRESTOR.

3. PLUMBING FIXTURE.

4. HORIZONTAL HOT WATER OR COLD WATER

BRANCH PIPING.

5. VERTICAL HOT WATER OR COLD WATER

BRANCH PIPING.

6. LOCATE AT EACH WATER BRANCH PIPE

SERVING A SINGLE PLUMBING FIXTURE OR

PLUMBING EQUIPMENT.

7. SUM OF WSFU RATING OF WATER HAMMER

ARRESTOR(S) SHALL BE EQUAL TO OR

GREATER THAN THE DEMAND OF THE

BRANCHES.

WATER HAMMER ARRESTOR UNIT SIZE CHART

UNIT SIZE WATER SUPPLY FIXTURE UNITS

A------------------(1-11) WSFUs B------------------(12-32) WSFUs C------------------(33-60) WSFUs D------------------(61-113) WSFUs E------------------(114-154) WSFUs F------------------(155-330) WSFUs

MULTI-PLUMBING FIXTURES BRANCH LINES MORE THAN 20' IN LENGTH

3 3 3 3

3 3 3 3

OVER 20'

MULTI-PLUMBING FIXTURES BRANCH LINES LESS THAN 20' IN LENGTH

3 3 3 3

3 3 3 3

UP TO 20'

4 4

CW

HW

INDIVIDUAL PLUMBING FIXTURE BRANCH LINE

WATER CLOSET

WATER CLOSET FLUSH VALVE

FLUSH TANK

8 8 - 5 5 -

- 2.5 2.5 -5 5

URINAL FLUSH VALVE -4 4 - - -

-2 2 - - -URINAL FLUSH TANK

PUBLIC PRIVATE

TOTAL CW HW TOTAL CW HW

WEIGHT IN WSFUs

FIXTURE

TYPE OF SUPPLY

CONTROL

1.52 1.5 1LAVATORY FAUCET 1 1

34 2 2BATHTUB FAUCET 1.5 1.5

34 2 2SHOWER HEAD MIXING VALVE 1 2

2 1 2

8 8 3

6 6 3

BATHROOM GROUP FLUSH VALVE CLOSET

BATHROOM GROUP FLUSH TANK CLOSET

SEPARATE SHOWER MIXING VALVE

FAUCET

FAUCET

FAUCET

SERVICE SINK

LAUNDRY TUBS (1-3)

COMBINATION FIXT.

GENERAL NOTE:

A. PROVIDED WATER HAMMER ARRESTORS

SHALL BE ASSE 1010 RATED OR PDI-WH 201

COMPLIANT.

B. SCOPE OF THIS DETAIL SHALL BE APPLICABLE

TO ALL PLUMBING FIXTURES AND EQUIPMENT

THAT HAVE QUICK CLOSING VALVES. THIS

SHALL INCLUDE BUT NOT BE LIMITED TO

FLUSH VALVES, BEVERAGE DISPENSING

EQUIPMENT, ICE MAKERS, AND WASHERS.

C. ALL POSSIBLE CONDITIONS AND INSTALLATION

SCENARIOS NOT REPRESENTED, WATER

HAMMER ARRESTORS SHALL BE INSTALLED IN

WATER PIPING IN ACCORDANCE WITH PDI-WH

201 AS THIS DETAIL IS PROVIDED FOR DESIGN

INTENT.

D. WHERE SUPPLY BOXES HAVE INTEGRAL

WATER HAMMER ARRESTORS, SEPARATE

PIPE INSTALLED WATER HAMMER ARRESTORS

SHALL NOT BE REQUIRED FOR THE

APPLICABLE PIECE OF EQUIPMENT SUPPLIED

FROM THE SUPPLY BOX.

E. WHERE REQUIRED BY APPLICABLE PLUMBING

CODE, WATER HAMMER ARRESTORS SHALL

BE INSTALLED IN ACCESSIBLE LOCATIONS.

1. SHUTOFF VALVE LOCKED OPEN.

2. TEMPERATURE GAUGE.

3. EYEWASH STATION. RIM TO BE 36"

ABOVE FINISHED FLOOR.

4. EYEWASH STATION PLACARED

FURNISHED AND INSTALLED BY

PLUMBING CONTRACTOR.

5. EMERGENCY THERMOSTATIC

MIXING VALVE.

6. PROVIDE ACCESS PANEL TO

SERVICE EMERGENCY

THERMOSTATIC MIXING VALVE,

TEMPERATURE GAUGES, AND

SHUTOFF VALVES.

7. FLOOR DRAIN TO BE LOCATED

DIRECTLY BELOW SHOWER HEAD.

8. COLD WATER.

9. HOT WATER.

10. TEMPERED WATER.

11. WASTE PIPING FOR FLOOR DRAIN

AND EYEWASH TO BE DRAINED

SEPARATELY.

12. VENT PIPE.

KEYED NOTES:

1. FINISHED FLOOR.

2. STRAINER

3. TRAP GUARD SHOWN IN CLOSED

POSITION.

A. TRAP GUARD SHALL BE

FACTORY FITTED TO MATCH

EACH FLOOR DRAIN BY SIZE,

MODEL, AND MANUFACTURER.

B. FLOOR SINK/HUB DRAIN TRAP

GUARD INSTALLATION IS

SIMILAR.

C. INSTALLATION OF TRAP GUARD

TO BE IN ACCORDANCE WITH

MANUFACTURER'S

RECOMMENDATIONS.

GENERAL NOTES: KEYED NOTES:

1. FINISH FLOOR SLAB - SLOPE

TO DRAIN.

2. WATER PROOFING

MEMBRANE. FLASHING

FLANGE (IF APPLICABLE).

3. STRUCTURAL SLAB

4. FLOOR DRAIN BODY.

A. SLOPE FLOOR TO DRAIN TO

FLOOR DRAIN.

GENERAL NOTES: KEYED NOTES:

INTERIOR FLOOR CLEANOUT

FLOW

KEYED NOTES:

1. CLEANOUT WITH COVER

RATED FOR EXPECTED

WHEEL LOADING REFER TO

SPECIFICATIONS AND PLANS

FOR TYPE AND LOCATIONS.

2. TOP FLUSH WITH FINISHED

FLOOR.

3. FINISHED FLOOR LEVEL.

4. FULL PIPE SIZE EXTENSION.

PROVIDE SAME SIZE AS LINE

SERVED UP TO 4".

5. COMBINATION WYE AND 1/8"

BEND OR AS CODE

REQUIRED.

6. BUILDING WASTE DRAIN

MATERIAL AND SIZE AS

SPECIFIED.

7 6

1. FINISHED FLOOR.

2. CUT OFF EXCESS PIPE 1" A.F.F.

3. INDIRECT DRAIN PIPE.

4. PROVIDE AIR GAP. CONSULT

LOCAL CODES FOR APPROVED

AIR GAP SIZE. BEVEL PIPE END

AT 45°.

5. PROVIDE PIPE REDUCER NO

LESS THAN TWO NOMINAL PIPE

SIZES LARGER THAN MAIN

WASTE PIPING.

KEYED NOTES:

M

IN

SEE PLANS

EXTERIOR CLEANOUT

KEYED NOTES:

1. 6" THICK BY 18" SQUARE

CONCRETE PAD.

2. "CO" TO BE CAST IN COVER.

3. CAST IRON CLEANOUT WITH

COVER FOR DUTY

REQUIRED.

4. GRADE FOR PAVING.

5. CAST IRON LONG SWEEP 1/4

BEND OR CAST IRON COMB,"

Y 1/8" "& BEND. (USE

REDUCING TYPE WHERE

REQUIRED).

6. BUILDING DRAIN OR SEWER

MATERIAL AND SIZE

SPECIFIED.

THREADED

CLEANOUT

PLUG

FINISHED

WALL

SURFACE

COVER PLATE WITH

SECURING SCREW

CLEANOUT TEE

HW SUPPLY

T W

F

SINK OR LAVATORY

THERMOSTATIC

MIXING VALVE

ASSE 1070

CW SUPPLY

THERMOSTATIC

MIXING VALVE

ASSE 1071.

T W

F

EYEWASH

COUNTER

C W

C W

CW

HW

TW 85F

SHUT-OFF (TYP.)

A S

S E

B A

C K

F L O

W

NOTES:

1. ALL PIPES AND VALVING SHALL

BE LOCATED WITHIN SINK

CASEWORK (UNLESS OTHERWISE

NOTED).

2. COORDINATE EXACT LOCATION

OF EYEWASH WITH ARCHITECT AND

IN ACCORDANCE WITH

MANUFACTURER'S REQUIREMENTS.

3. COORDINATE DRILLING OF

COUNTER TOP WITH CASEWORK

VENDOR.

1. EXTERIOR WALL. REFER TO

ARCHITECHURAL DRAWINGS

FOR CONSTRUCTION DETAIL.

2. DOWNSPOUT NOZZLE WITH

STAINLES STEEL SCREEN.

3. REFER TO PLANS FOR

LOCATION OF DOWNSPOUT

NOZZLE.

4. STORM PIPING, REFER TO

PLANS AND SPECIFICATIONS

FOR MATERIALS.

KEYED NOTES:

KEYED NOTES:

NOTE: TRAP PRIMER LINE SHALL NOT EXCEED 20 FT.

1. SHUT-OFF VALVE.

2. DOMESTIC COLD WATER LINE.

3. TRAP PRIMER VALVE WITH

BACKFLOW PREVENTER AND

VACCUM BREAK.

4. DISTRIBUTION UNIT FOR

MULTIPLE FLOOR DRAINS. (OMIT

DISTRIBUTION UNIT WHEN

SERVING SINGLE DRAIN.)

5. MINIMUM 1/2" COPPER FLOOR

DRAIN TRAP MAKE-UP WATER

LINE. (TYPICAL)

6. WATER SEAL.

7. SLOPE PIPING BELOW SLAB TO

FLOOR DRAIN.

8. 1/2" SUPPLY SIZE.

9. IF DRAIN DOES NOT HAVE

INTEGRAL TRAP PRIMER

CONNECTION, PROVIDE TRAP

PRIMER FITTING EQUAL TO ZURN

Z1023

9 6

KEYED NOTES:

1. HYDRANT SUPPORT.

2. SEAL ROOF PENETRATION.

3. ROOF SYSTEM.

4. UNDER DECK FLANGE.

5. MOUNTING BOLTS.

6. SUPPLY INLET.

CW SUPPLY

STOP (TYP.)

CW SUPPLY

HW SUPPLY

TEMPERED HOT

WATER

HANDWASHING SINK

THERMOSTATIC

MIXING VALVE

(WITH INTEGRAL

CHECKS)

KEYED NOTES:

1. DOMESTIC WATER SUPPLY.

2. STRAINER.

3. ASSE 1022 RATED BACKFLOW

PREVENTER FOR BEVERAGE

DISPENSING EQUIPMENT EQUAL TO

WATTS SD-3. CONNECT WASTE PIPE TO

VENT OPENING AND DRAIN INDIRECT TO

ADJACENT FLOOR DRAIN/SINK.

4. [COFFEE BREWER, ESPRESSO

MACHINE, TEA BREWER, JUICE

DISPENSER.]

5. [ASSE 1024 RATED DUAL CHECK

BACKFLOW PREVENTER FOR

BEVERAGE DISPENSING EQUIPMENT

EQUAL TO WATTS LF7.]

6. [COFFEE BREWER, ESPRESSO

MACHINE, ICE MACHINE, NON-

CARBONATED DRINK DISPENSOR.]

7. [ASSE 1032 RATED DUAL CHECK

BACKFLOW PREVENTER FOR

CARBONATED BEVERAGE DISPENSERS,

POST MIX TYPE, AND NON-

CARBONATED BEVERAGE DISPENSERS

EQUAL TO WATTS SD-2.]

8. [CARBONATED BEVERAGE DISPENSER,

NON-CARBONATED BEVERAGE

DISPENSER, POST MIX TYPE BEVERAGE

DISPENSER.]

GENERAL NOTES:

A. DIAGRAM IS SCHEMATIC. BACKFLOW PREVENTERS

SHALL BE INSTALLED IN COMPLIANCE WITH

MANUFACTURER'S REQUIREMENTS AND ONLY IN

INSTALLATION ORIENTATIONS PERMITTED BY

MANUFACTURER.

B. BACKFLOW PREVENTERS SHALL BE INSTALLED WITH

READY ACCESS. CONCEALMENT IS NOT PERMITTED.

WHERE A SUPPLY BOX IS INDICATED, BACKFLOW

PREVENTER SHALL BE INSTALLED IN BETWEEN

SUPPLY BOX OUTLET AND FINAL EQUIPMENT

CONNECTION.

ZVB

FINISH FLOOR

NOTE: COORDINATE FINAL

LOCATION OF

VALVE CABINETS WITH

ARCHITECTURAL

ELEVATIONS AND INSTALL PER NFPA

99.

1/2" MEDICAL AIR

3/4" MEDICAL VACUUM

1/2" OXYGEN

FAUCET

CL

NOTES:

MOP SINK

CWHW

CHECK

VALVES

1. SEAL TOP OF SINK TO WALL USING A CONTINUOUS BEAD OF SILICONE CAULKING,

WHEREVER SINK ABUTS WALL.

2. FOR EXTERIOR MASONRY AND SOLID WALLS APPLICATION PROVIDE SURFACE MOUNT

WATER SUPPLY LINES. WHEN POSSIBLE ROUTE WATER SUPPLY LINES INSIDE INTERIOR

STUD WALLS.

3. INCLUDE MOP HANGER, HOSE & HOSE BRACKET, WALL AND BUMPER GUARDS.

RTA DATE

DRAWN BY

CHECKED BY

A & E FILE NO

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING & CONTRACT ADMINISTRATION

FRANKFORT, KENTUCKY

AS BUILT DATE

DECA LOG #

ACCOUNT NO.

DRAWING NO.

DESCRIPTION OF REVISIONS DATE

DRAWING DATE

PHASE

REVISION HISTORY OF THIS DRAWING

DESCRIPTION OF REVISIONS DATE

DRAWING INFORMATION

435-CBQA-KS64-00

A

1538 ALEXANDRIA PIKE,

SUITE 11

FT. THOMAS, KENTUCKY

41075 859-442-8050

WWW.KLHENGRS.COM

O W

N E

R S

H

IP

O F

I N

S T

R U

M E

N T

S O

F S

E R

V

IC

E

A ll re p o rt s p la n s s p e c ifi c a tio n s c o m p u te r fil e s fie ld d a ta n o te s a n d o th e r d o c u m e n ts a n d in s tr u m e n ts p re p a re d b y t h e C o n s u lt a n t a s in s tr u m e n ts o f s e rv ic e s h a ll re m a in t h e p ro p e rt y o f th e C o n s u lt a n t.

T h e C o n s u lt a n t s h a ll re ta in a ll c o m m o n l a w s ta tu to ry a n d o th e r re s e rv e d ri g h ts in c lu d in g w ith o u t lim ita tio n th e c o p y ri g h t th e re to

KOHRS LONNEMANN HEIL

ENGINEERS, INC.

KFE

DMR

P-502

PLUMBING DETAILS05/15/26

R25092.00

KSU - HEALTH SCIENCE CENTER

KLH PROJECT # 27734

SCALE: NONE

221313.00-06 - VENT THROUGH ROOF

SCALE: NONE

221319.00-07 - WATER HAMMER ARRESTOR DETAIL

SCALE: NONE

224000.00-46 - EYEWASH/SHOWER STATION DETAIL

SCALE: NONE

221319.00-02 - FLOOR DRAIN TRAP SEAL DEVICE

SCALE: NONE

221316.00-01 - FLOOR DRAIN DETAIL

SCALE: NONE

221316.00-04 - INTERIOR FLOOR CLEANOUT

SCALE: NONE

221316.00-03 - HUB DRAIN DETAIL

SCALE: NONE

221316.00-05 - EXTERIOR GRADE CLEANOUT

SCALE: NONE

221319.00-05 - WALL CLEANOUT DETAIL

SCALE: NONE

221119.00-06 - DECK MOUNTED EYEWASH DETAIL

SCALE: NONE

221413.00-03 - DOWNSPOUT NOZZLE

SCALE: NONE

221119.00-07 - TRAP PRIMER DETAIL

SCALE: NONE

221119.00-01 - ROOF HYDRANT WITH RESEVOIR

SCALE: NONE

223001.00-01 - THERMOSTATIC MIXING VALVE TMV DETAIL

SCALE: NONE

221113.00-04 - BEVERAGE EQUIPMENT BACKFLOW PREVENTER DETAIL

SCALE: NONE

221550.00-15 - TRIPLE MEDICAL GAS ZONE VALVE BOX

SCALE: NONE

224000.00-02 - MOP SINK DETAIL

KEYED NOTES:

1. 3" MINIMUM VENT TEMINAL TO BE

A MINIMUM OF 1'-0" OR 6" ABOVE

LOCAL SNOW LEVELS. CONSULT

LOCAL CODES IF THEY VARY

FROM THIS STANDARD.

2. PIPE SEALANT. COORDINATE

SEALANT TYPE WITH ROOFING

CONTRACTOR.

3. STAINLESS STEEL PIPE CLAMP.

4. VENT FLASHING. COORDINATE

FLASHING MATERIAL AND

INSTALLATION WITH ROOFING

CONTRACTOR.

5. ROOFING SYSTEM.

6. THERMAL ENVOLOPE

INSULATION.

7. ANY CHANGE IN VENT SIZE SHALL

BE MADE NOT LESS THAN 1'-0"

INSIDE THE THERMAL ENVELOPE.

1'-0" MINIMUM

1'-0" MINIMUM

KEYED NOTES:

1. HORIZONTAL OR VERTICAL HOT OR COLD

WATER MAIN.

2. WATER HAMMER ARRESTOR.

3. PLUMBING FIXTURE.

4. HORIZONTAL HOT WATER OR COLD WATER

BRANCH PIPING.

5. VERTICAL HOT WATER OR COLD WATER

BRANCH PIPING.

6. LOCATE AT EACH WATER BRANCH PIPE

SERVING A SINGLE PLUMBING FIXTURE OR

PLUMBING EQUIPMENT.

7. SUM OF WSFU RATING OF WATER HAMMER

ARRESTOR(S) SHALL BE EQUAL TO OR

GREATER THAN THE DEMAND OF THE

BRANCHES.

WATER HAMMER ARRESTOR UNIT SIZE CHART

UNIT SIZE WATER SUPPLY FIXTURE UNITS

A------------------(1-11) WSFUs B------------------(12-32) WSFUs C------------------(33-60) WSFUs D------------------(61-113) WSFUs E------------------(114-154) WSFUs F------------------(155-330) WSFUs

MULTI-PLUMBING FIXTURES BRANCH LINES MORE THAN 20' IN LENGTH

3 3 3 3

3 3 3 3

OVER 20'

MULTI-PLUMBING FIXTURES BRANCH LINES LESS THAN 20' IN LENGTH

3 3 3 3

3 3 3 3

UP TO 20'

4 4

CW

HW

INDIVIDUAL PLUMBING FIXTURE BRANCH LINE

WATER CLOSET

WATER CLOSET FLUSH VALVE

FLUSH TANK

8 8 - 5 5 -

- 2.5 2.5 -5 5

URINAL FLUSH VALVE -4 4 - - -

-2 2 - - -URINAL FLUSH TANK

PUBLIC PRIVATE

TOTAL CW HW TOTAL CW HW

WEIGHT IN WSFUs

FIXTURE

TYPE OF SUPPLY

CONTROL

1.52 1.5 1LAVATORY FAUCET 1 1

34 2 2BATHTUB FAUCET 1.5 1.5

34 2 2SHOWER HEAD MIXING VALVE 1 2

2 1 2

8 8 3

6 6 3

BATHROOM GROUP FLUSH VALVE CLOSET

BATHROOM GROUP FLUSH TANK CLOSET

SEPARATE SHOWER MIXING VALVE

FAUCET

FAUCET

FAUCET

SERVICE SINK

LAUNDRY TUBS (1-3)

COMBINATION FIXT.

GENERAL NOTE:

A. PROVIDED WATER HAMMER ARRESTORS

SHALL BE ASSE 1010 RATED OR PDI-WH 201

COMPLIANT.

B. SCOPE OF THIS DETAIL SHALL BE APPLICABLE

TO ALL PLUMBING FIXTURES AND EQUIPMENT

THAT HAVE QUICK CLOSING VALVES. THIS

SHALL INCLUDE BUT NOT BE LIMITED TO

FLUSH VALVES, BEVERAGE DISPENSING

EQUIPMENT, ICE MAKERS, AND WASHERS.

C. ALL POSSIBLE CONDITIONS AND INSTALLATION

SCENARIOS NOT REPRESENTED, WATER

HAMMER ARRESTORS SHALL BE INSTALLED IN

WATER PIPING IN ACCORDANCE WITH PDI-WH

201 AS THIS DETAIL IS PROVIDED FOR DESIGN

INTENT.

D. WHERE SUPPLY BOXES HAVE INTEGRAL

WATER HAMMER ARRESTORS, SEPARATE

PIPE INSTALLED WATER HAMMER ARRESTORS

SHALL NOT BE REQUIRED FOR THE

APPLICABLE PIECE OF EQUIPMENT SUPPLIED

FROM THE SUPPLY BOX.

E. WHERE REQUIRED BY APPLICABLE PLUMBING

CODE, WATER HAMMER ARRESTORS SHALL

BE INSTALLED IN ACCESSIBLE LOCATIONS.

1. SHUTOFF VALVE LOCKED OPEN.

2. TEMPERATURE GAUGE.

3. EYEWASH STATION. RIM TO BE 36"

ABOVE FINISHED FLOOR.

4. EYEWASH STATION PLACARED

FURNISHED AND INSTALLED BY

PLUMBING CONTRACTOR.

5. EMERGENCY THERMOSTATIC

MIXING VALVE.

6. PROVIDE ACCESS PANEL TO

SERVICE EMERGENCY

THERMOSTATIC MIXING VALVE,

TEMPERATURE GAUGES, AND

SHUTOFF VALVES.

7. FLOOR DRAIN TO BE LOCATED

DIRECTLY BELOW SHOWER HEAD.

8. COLD WATER.

9. HOT WATER.

10. TEMPERED WATER.

11. WASTE PIPING FOR FLOOR DRAIN

AND EYEWASH TO BE DRAINED

SEPARATELY.

12. VENT PIPE.

KEYED NOTES:

1. FINISHED FLOOR.

2. STRAINER

3. TRAP GUARD SHOWN IN CLOSED

POSITION.

A. TRAP GUARD SHALL BE

FACTORY FITTED TO MATCH

EACH FLOOR DRAIN BY SIZE,

MODEL, AND MANUFACTURER.

B. FLOOR SINK/HUB DRAIN TRAP

GUARD INSTALLATION IS

SIMILAR.

C. INSTALLATION OF TRAP GUARD

TO BE IN ACCORDANCE WITH

MANUFACTURER'S

RECOMMENDATIONS.

GENERAL NOTES: KEYED NOTES:

1. FINISH FLOOR SLAB - SLOPE

TO DRAIN.

2. WATER PROOFING

MEMBRANE. FLASHING

FLANGE (IF APPLICABLE).

3. STRUCTURAL SLAB

4. FLOOR DRAIN BODY.

A. SLOPE FLOOR TO DRAIN TO

FLOOR DRAIN.

GENERAL NOTES: KEYED NOTES:

INTERIOR FLOOR CLEANOUT

FLOW

KEYED NOTES:

1. CLEANOUT WITH COVER

RATED FOR EXPECTED

WHEEL LOADING REFER TO

SPECIFICATIONS AND PLANS

FOR TYPE AND LOCATIONS.

2. TOP FLUSH WITH FINISHED

FLOOR.

3. FINISHED FLOOR LEVEL.

4. FULL PIPE SIZE EXTENSION.

PROVIDE SAME SIZE AS LINE

SERVED UP TO 4".

5. COMBINATION WYE AND 1/8"

BEND OR AS CODE

REQUIRED.

6. BUILDING WASTE DRAIN

MATERIAL AND SIZE AS

SPECIFIED.

7 6

1. FINISHED FLOOR.

2. CUT OFF EXCESS PIPE 1" A.F.F.

3. INDIRECT DRAIN PIPE.

4. PROVIDE AIR GAP. CONSULT

LOCAL CODES FOR APPROVED

AIR GAP SIZE. BEVEL PIPE END

AT 45°.

5. PROVIDE PIPE REDUCER NO

LESS THAN TWO NOMINAL PIPE

SIZES LARGER THAN MAIN

WASTE PIPING.

KEYED NOTES:

M

IN

SEE PLANS

EXTERIOR CLEANOUT

KEYED NOTES:

1. 6" THICK BY 18" SQUARE

CONCRETE PAD.

2. "CO" TO BE CAST IN COVER.

3. CAST IRON CLEANOUT WITH

COVER FOR DUTY

REQUIRED.

4. GRADE FOR PAVING.

5. CAST IRON LONG SWEEP 1/4

BEND OR CAST IRON COMB,"

Y 1/8" "& BEND. (USE

REDUCING TYPE WHERE

REQUIRED).

6. BUILDING DRAIN OR SEWER

MATERIAL AND SIZE

SPECIFIED.

THREADED

CLEANOUT

PLUG

FINISHED

WALL

SURFACE

COVER PLATE WITH

SECURING SCREW

CLEANOUT TEE

HW SUPPLY

T W

F

SINK OR LAVATORY

THERMOSTATIC

MIXING VALVE

ASSE 1070

CW SUPPLY

THERMOSTATIC

MIXING VALVE

ASSE 1071.

T W

F

EYEWASH

COUNTER

C W

C W

CW

HW

TW 85F

SHUT-OFF (TYP.)

A S

S E

B A

C K

F L O

W

NOTES:

1. ALL PIPES AND VALVING SHALL

BE LOCATED WITHIN SINK

CASEWORK (UNLESS OTHERWISE

NOTED).

2. COORDINATE EXACT LOCATION

OF EYEWASH WITH ARCHITECT AND

IN ACCORDANCE WITH

MANUFACTURER'S REQUIREMENTS.

3. COORDINATE DRILLING OF

COUNTER TOP WITH CASEWORK

VENDOR.

1. EXTERIOR WALL. REFER TO

ARCHITECHURAL DRAWINGS

FOR CONSTRUCTION DETAIL.

2. DOWNSPOUT NOZZLE WITH

STAINLES STEEL SCREEN.

3. REFER TO PLANS FOR

LOCATION OF DOWNSPOUT

NOZZLE.

4. STORM PIPING, REFER TO

PLANS AND SPECIFICATIONS

FOR MATERIALS.

KEYED NOTES:

KEYED NOTES:

NOTE: TRAP PRIMER LINE SHALL NOT EXCEED 20 FT.

1. SHUT-OFF VALVE.

2. DOMESTIC COLD WATER LINE.

3. TRAP PRIMER VALVE WITH

BACKFLOW PREVENTER AND

VACCUM BREAK.

4. DISTRIBUTION UNIT FOR

MULTIPLE FLOOR DRAINS. (OMIT

DISTRIBUTION UNIT WHEN

SERVING SINGLE DRAIN.)

5. MINIMUM 1/2" COPPER FLOOR

DRAIN TRAP MAKE-UP WATER

LINE. (TYPICAL)

6. WATER SEAL.

7. SLOPE PIPING BELOW SLAB TO

FLOOR DRAIN.

8. 1/2" SUPPLY SIZE.

9. IF DRAIN DOES NOT HAVE

INTEGRAL TRAP PRIMER

CONNECTION, PROVIDE TRAP

PRIMER FITTING EQUAL TO ZURN

Z1023

9 6

KEYED NOTES:

1. HYDRANT SUPPORT.

2. SEAL ROOF PENETRATION.

3. ROOF SYSTEM.

4. UNDER DECK FLANGE.

5. MOUNTING BOLTS.

6. SUPPLY INLET.

CW SUPPLY

STOP (TYP.)

CW SUPPLY

HW SUPPLY

TEMPERED HOT

WATER

HANDWASHING SINK

THERMOSTATIC

MIXING VALVE

(WITH INTEGRAL

CHECKS)

KEYED NOTES:

1. DOMESTIC WATER SUPPLY.

2. STRAINER.

3. ASSE 1022 RATED BACKFLOW

PREVENTER FOR BEVERAGE

DISPENSING EQUIPMENT EQUAL TO

WATTS SD-3. CONNECT WASTE PIPE TO

VENT OPENING AND DRAIN INDIRECT TO

ADJACENT FLOOR DRAIN/SINK.

4. [COFFEE BREWER, ESPRESSO

MACHINE, TEA BREWER, JUICE

DISPENSER.]

5. [ASSE 1024 RATED DUAL CHECK

BACKFLOW PREVENTER FOR

BEVERAGE DISPENSING EQUIPMENT

EQUAL TO WATTS LF7.]

6. [COFFEE BREWER, ESPRESSO

MACHINE, ICE MACHINE, NON-

CARBONATED DRINK DISPENSOR.]

7. [ASSE 1032 RATED DUAL CHECK

BACKFLOW PREVENTER FOR

CARBONATED BEVERAGE DISPENSERS,

POST MIX TYPE, AND NON-

CARBONATED BEVERAGE DISPENSERS

EQUAL TO WATTS SD-2.]

8. [CARBONATED BEVERAGE DISPENSER,

NON-CARBONATED BEVERAGE

DISPENSER, POST MIX TYPE BEVERAGE

DISPENSER.]

GENERAL NOTES:

A. DIAGRAM IS SCHEMATIC. BACKFLOW PREVENTERS

SHALL BE INSTALLED IN COMPLIANCE WITH

MANUFACTURER'S REQUIREMENTS AND ONLY IN

INSTALLATION ORIENTATIONS PERMITTED BY

MANUFACTURER.

B. BACKFLOW PREVENTERS SHALL BE INSTALLED WITH

READY ACCESS. CONCEALMENT IS NOT PERMITTED.

WHERE A SUPPLY BOX IS INDICATED, BACKFLOW

PREVENTER SHALL BE INSTALLED IN BETWEEN

SUPPLY BOX OUTLET AND FINAL EQUIPMENT

CONNECTION.

ZVB

FINISH FLOOR

NOTE: COORDINATE FINAL

LOCATION OF

VALVE CABINETS WITH

ARCHITECTURAL

ELEVATIONS AND INSTALL PER NFPA

99.

1/2" MEDICAL AIR

3/4" MEDICAL VACUUM

1/2" OXYGEN

FAUCET

CL

NOTES:

MOP SINK

CWHW

CHECK

VALVES

1. SEAL TOP OF SINK TO WALL USING A CONTINUOUS BEAD OF SILICONE CAULKING,

WHEREVER SINK ABUTS WALL.

2. FOR EXTERIOR MASONRY AND SOLID WALLS APPLICATION PROVIDE SURFACE MOUNT

WATER SUPPLY LINES. WHEN POSSIBLE ROUTE WATER SUPPLY LINES INSIDE INTERIOR

STUD WALLS.

3. INCLUDE MOP HANGER, HOSE & HOSE BRACKET, WALL AND BUMPER GUARDS.

RTA DATE

DRAWN BY

CHECKED BY

A & E FILE NO

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING & CONTRACT ADMINISTRATION

FRANKFORT, KENTUCKY

AS BUILT DATE

DECA LOG #

ACCOUNT NO.

DRAWING NO.

DESCRIPTION OF REVISIONS DATE

DRAWING DATE

PHASE

REVISION HISTORY OF THIS DRAWING

DESCRIPTION OF REVISIONS DATE

DRAWING INFORMATION

435-CBQA-KS64-00

A

1538 ALEXANDRIA PIKE,

SUITE 11

FT. THOMAS, KENTUCKY

41075 859-442-8050

WWW.KLHENGRS.COM

O W

N E

R S

H

IP

O F

I N

S T

R U

M E

N T

S O

F S

E R

V

IC

E

A ll re p o rt s p la n s s p e c ifi c a tio n s c o m p u te r fil e s fie ld d a ta n o te s a n d o th e r d o c u m e n ts a n d in s tr u m e n ts p re p a re d b y t h e C o n s u lt a n t a s in s tr u m e n ts o f s e rv ic e s h a ll re m a in t h e p ro p e rt y o f th e C o n s u lt a n t.

T h e C o n s u lt a n t s h a ll re ta in a ll c o m m o n l a w s ta tu to ry a n d o th e r re s e rv e d ri g h ts in c lu d in g w ith o u t lim ita tio n th e c o p y ri g h t th e re to

KOHRS LONNEMANN HEIL

ENGINEERS, INC.

KFE

DMR

P-502

PLUMBING DETAILS05/15/26

R25092.00

KSU - HEALTH SCIENCE CENTER

KLH PROJECT # 27734

SCALE: NONE

221313.00-06 - VENT THROUGH ROOF

SCALE: NONE

221319.00-07 - WATER HAMMER ARRESTOR DETAIL

SCALE: NONE

224000.00-46 - EYEWASH/SHOWER STATION DETAIL

SCALE: NONE

221319.00-02 - FLOOR DRAIN TRAP SEAL DEVICE

SCALE: NONE

221316.00-01 - FLOOR DRAIN DETAIL

SCALE: NONE

221316.00-04 - INTERIOR FLOOR CLEANOUT

SCALE: NONE

221316.00-03 - HUB DRAIN DETAIL

SCALE: NONE

221316.00-05 - EXTERIOR GRADE CLEANOUT

SCALE: NONE

221319.00-05 - WALL CLEANOUT DETAIL

SCALE: NONE

221119.00-06 - DECK MOUNTED EYEWASH DETAIL

SCALE: NONE

221413.00-03 - DOWNSPOUT NOZZLE

SCALE: NONE

221119.00-07 - TRAP PRIMER DETAIL

SCALE: NONE

221119.00-01 - ROOF HYDRANT WITH RESEVOIR

SCALE: NONE

223001.00-01 - THERMOSTATIC MIXING VALVE TMV DETAIL

SCALE: NONE

221113.00-04 - BEVERAGE EQUIPMENT BACKFLOW PREVENTER DETAIL

SCALE: NONE

221550.00-15 - TRIPLE MEDICAL GAS ZONE VALVE BOX

SCALE: NONE

224000.00-02 - MOP SINK DETAIL

Space

M

W

6" S1.19

2" S1.19

2" S1.19

6" S1.19

Space

M

W

4" C1.6

2" C1.6

4" S1.2

4" V1.2

4" V1.2 - UP

4" V1.2

4" V1.2 - UP/DN

4" S1.2

2" C1.6

4" S1.2 - UP/DN

2" C1.6 - UP

M

W

4" V1.2 - UP/DN

4" V1.2

2" C1.6

1 1/2" C1.6

Space

Space

JANITOR STORAGE

4" S1.19

4" C1.6

JANITOR STORAGE

4" C1.6

4" C1.6

4" C1.6

EWH1 EWH2

HPT1

DBP1

ET1

CP1

RTA DATE

DRAWN BY

CHECKED BY

A & E FILE NO

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING & CONTRACT ADMINISTRATION

FRANKFORT, KENTUCKY

AS BUILT DATE

DECA LOG #

ACCOUNT NO.

DRAWING NO.

DESCRIPTION OF REVISIONS DATE

DRAWING DATE

PHASE

REVISION HISTORY OF THIS DRAWING

DESCRIPTION OF REVISIONS DATE

DRAWING INFORMATION

435-CBQA-KS64-00

A

1538 ALEXANDRIA PIKE,

SUITE 11

FT. THOMAS, KENTUCKY

41075 859-442-8050

WWW.KLHENGRS.COM

O W

N E

R S

H

IP

O F

I N

S T

R U

M E

N T

S O

F S

E R

V

IC

E

A ll re p o rt s p la n s s p e c ifi c a tio n s c o m p u te r fil e s fie ld d a ta n o te s a n d o th e r d o c u m e n ts a n d in s tr u m e n ts p re p a re d b y t h e C o n s u lt a n t a s in s tr u m e n ts o f s e rv ic e s h a ll re m a in t h e p ro p e rt y o f th e C o n s u lt a n t.

T h e C o n s u lt a n t s h a ll re ta in a ll c o m m o n l a w s ta tu to ry a n d o th e r re s e rv e d ri g h ts in c lu d in g w ith o u t lim ita tio n th e c o p y ri g h t th e re to

KOHRS LONNEMANN HEIL

ENGINEERS, INC.

KFE

DMR

P-741

PLUMBING ENLARGED PLANS05/15/26

R25092.00

KSU - HEALTH SCIENCE CENTER

KLH PROJECT # 27734

3/8" = 1'-0"

PLUMBING - ENLARGED UNDERGROUND PLAN - LEVEL 1 - RESTROOMS

3/8" = 1'-0"

PLUMBING - ENLARGED ABOVE GROUND PLAN - LEVEL 01 - RESTROOMS

3/8" = 1'-0"

PLUMBING - ENLARGED ABOVE GROUND PLAN - LEVEL 02 - RESTROOMS

3/8" = 1'-0"

PLUMBING - ENLARGED ABOVE GROUND PLAN - LEVEL 03 - RESTROOMS

Pipe Type Legend

Mark Color System Name Pipe Material

C1.6

S1.19

S1.2

V1.2

C1 - Domestic Cold Water

S1 - Sanitary

S1 - Sanitary

V1 - Vent

6 - Copper - Type L - ASTM B88

19 - PVC - Schedule 40 - ASTM D1785/D2665

2 - Cast Iron - Hubless - ASTM A888

2 - Cast Iron - Hubless - ASTM A888

3/8" = 1'-0"

PLUMBING - ENLARGED UNDERGROUND PLAN - LEVEL 1 - JANITOR STORAGE

3/8" = 1'-0"

PLUMBING - ENLARGED ABOVE GROUND PLAN - LEVEL 1 - JANITOR STORAGE

Space

M

W

6" S1.19

2" S1.19

2" S1.19

6" S1.19

Space

M

W

4" C1.6

2" C1.6

4" S1.2

4" V1.2

4" V1.2 - UP

4" V1.2

4" V1.2 - UP/DN

4" S1.2

2" C1.6

4" S1.2 - UP/DN

2" C1.6 - UP

M

W

4" V1.2 - UP/DN

4" V1.2

2" C1.6

1 1/2" C1.6

Space

Space

JANITOR STORAGE

4" S1.19

4" C1.6

JANITOR STORAGE

4" C1.6

4" C1.6

4" C1.6

EWH1 EWH2

HPT1

DBP1

ET1

CP1

RTA DATE

DRAWN BY

CHECKED BY

A & E FILE NO

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING & CONTRACT ADMINISTRATION

FRANKFORT, KENTUCKY

AS BUILT DATE

DECA LOG #

ACCOUNT NO.

DRAWING NO.

DESCRIPTION OF REVISIONS DATE

DRAWING DATE

PHASE

REVISION HISTORY OF THIS DRAWING

DESCRIPTION OF REVISIONS DATE

DRAWING INFORMATION

435-CBQA-KS64-00

A

1538 ALEXANDRIA PIKE,

SUITE 11

FT. THOMAS, KENTUCKY

41075 859-442-8050

WWW.KLHENGRS.COM

O W

N E

R S

H

IP

O F

I N

S T

R U

M E

N T

S O

F S

E R

V

IC

E

A ll re p o rt s p la n s s p e c ifi c a tio n s c o m p u te r fil e s fie ld d a ta n o te s a n d o th e r d o c u m e n ts a n d in s tr u m e n ts p re p a re d b y t h e C o n s u lt a n t a s in s tr u m e n ts o f s e rv ic e s h a ll re m a in t h e p ro p e rt y o f th e C o n s u lt a n t.

T h e C o n s u lt a n t s h a ll re ta in a ll c o m m o n l a w s ta tu to ry a n d o th e r re s e rv e d ri g h ts in c lu d in g w ith o u t lim ita tio n th e c o p y ri g h t th e re to

KOHRS LONNEMANN HEIL

ENGINEERS, INC.

KFE

DMR

P-741

PLUMBING ENLARGED PLANS05/15/26

R25092.00

KSU - HEALTH SCIENCE CENTER

KLH PROJECT # 27734

3/8" = 1'-0"

PLUMBING - ENLARGED UNDERGROUND PLAN - LEVEL 1 - RESTROOMS

3/8" = 1'-0"

PLUMBING - ENLARGED ABOVE GROUND PLAN - LEVEL 01 - RESTROOMS

3/8" = 1'-0"

PLUMBING - ENLARGED ABOVE GROUND PLAN - LEVEL 02 - RESTROOMS

3/8" = 1'-0"

PLUMBING - ENLARGED ABOVE GROUND PLAN - LEVEL 03 - RESTROOMS

Pipe Type Legend

Mark Color System Name Pipe Material

C1.6

S1.19

S1.2

V1.2

C1 - Domestic Cold Water

S1 - Sanitary

S1 - Sanitary

V1 - Vent

6 - Copper - Type L - ASTM B88

19 - PVC - Schedule 40 - ASTM D1785/D2665

2 - Cast Iron - Hubless - ASTM A888

2 - Cast Iron - Hubless - ASTM A888

3/8" = 1'-0"

PLUMBING - ENLARGED UNDERGROUND PLAN - LEVEL 1 - JANITOR STORAGE

3/8" = 1'-0"

PLUMBING - ENLARGED ABOVE GROUND PLAN - LEVEL 1 - JANITOR STORAGE

RTA DATE

DRAWN BY

CHECKED BY

A & E FILE NO

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING & CONTRACT ADMINISTRATION

FRANKFORT, KENTUCKY

AS BUILT DATE

DECA LOG #

ACCOUNT NO.

DRAWING NO.

DESCRIPTION OF REVISIONS DATE

DRAWING DATE

PHASE

REVISION HISTORY OF THIS DRAWING

DESCRIPTION OF REVISIONS DATE

DRAWING INFORMATION

435-CBQA-KS64-00

A

1538 ALEXANDRIA PIKE,

SUITE 11

FT. THOMAS, KENTUCKY

41075 859-442-8050

WWW.KLHENGRS.COM

O W

N E

R S

H

IP

O F

I N

S T

R U

M E

N T

S O

F S

E R

V

IC

E

A ll re p o rt s p la n s s p e c ifi c a tio n s c o m p u te r fil e s fie ld d a ta n o te s a n d o th e r d o c u m e n ts a n d in s tr u m e n ts p re p a re d b y t h e C o n s u lt a n t a s in s tr u m e n ts o f s e rv ic e s h a ll re m a in t h e p ro p e rt y o f th e C o n s u lt a n t.

T h e C o n s u lt a n t s h a ll re ta in a ll c o m m o n l a w s ta tu to ry a n d o th e r re s e rv e d ri g h ts in c lu d in g w ith o u t lim ita tio n th e c o p y ri g h t th e re to

KOHRS LONNEMANN HEIL

ENGINEERS, INC.

KFE

DMR

P-901

PLUMBING ISOMETRICS05/15/26

R25092.00

KSU - HEALTH SCIENCE CENTER

KLH PROJECT # 27734

PLUMBING - SANITARY AND VENT ISOMETRIC

Pipe Type Legend

Mark Color System Name Pipe Material

S1.19

S1.2

S9.3

V1.2

S1 - Sanitary

S1 - Sanitary

S9 - Indirect Waste

V1 - Vent

19 - PVC - Schedule 40 - ASTM D1785/D2665

2 - Cast Iron - Hubless - ASTM A888

3 - Copper - DWV - ASTM B306

2 - Cast Iron - Hubless - ASTM A888

RTA DATE

DRAWN BY

CHECKED BY

A & E FILE NO

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING & CONTRACT ADMINISTRATION

FRANKFORT, KENTUCKY

AS BUILT DATE

DECA LOG #

ACCOUNT NO.

DRAWING NO.

DESCRIPTION OF REVISIONS DATE

DRAWING DATE

PHASE

REVISION HISTORY OF THIS DRAWING

DESCRIPTION OF REVISIONS DATE

DRAWING INFORMATION

435-CBQA-KS64-00

A

1538 ALEXANDRIA PIKE,

SUITE 11

FT. THOMAS, KENTUCKY

41075 859-442-8050

WWW.KLHENGRS.COM

O W

N E

R S

H

IP

O F

I N

S T

R U

M E

N T

S O

F S

E R

V

IC

E

A ll re p o rt s p la n s s p e c ifi c a tio n s c o m p u te r fil e s fie ld d a ta n o te s a n d o th e r d o c u m e n ts a n d in s tr u m e n ts p re p a re d b y t h e C o n s u lt a n t a s in s tr u m e n ts o f s e rv ic e s h a ll re m a in t h e p ro p e rt y o f th e C o n s u lt a n t.

T h e C o n s u lt a n t s h a ll re ta in a ll c o m m o n l a w s ta tu to ry a n d o th e r re s e rv e d ri g h ts in c lu d in g w ith o u t lim ita tio n th e c o p y ri g h t th e re to

KOHRS LONNEMANN HEIL

ENGINEERS, INC.

KFE

DMR

P-901

PLUMBING ISOMETRICS05/15/26

R25092.00

KSU - HEALTH SCIENCE CENTER

KLH PROJECT # 27734

PLUMBING - SANITARY AND VENT ISOMETRIC

Pipe Type Legend

Mark Color System Name Pipe Material

S1.19

S1.2

S9.3

V1.2

S1 - Sanitary

S1 - Sanitary

S9 - Indirect Waste

V1 - Vent

19 - PVC - Schedule 40 - ASTM D1785/D2665

2 - Cast Iron - Hubless - ASTM A888

3 - Copper - DWV - ASTM B306

2 - Cast Iron - Hubless - ASTM A888

PLUMBING
P-501 - Plumbing Details
P-502 - Plumbing Details
P-741 - Plumbing Enlarged Plans
P-901 - Plumbing Isometrics
P-902 - Plumbing Isometrics
MECHANICAL
M-001 - Mechanical Cover Sheet
M-101 - Mechanical Ductwork Level 01 Plan Overall
M-102 - Mechanical Ductwork Level 02 Plan Overall
M-103 - Mechanical Ductwork Level 03 Plan Overall
M-104 - Mechanical Ductwork Roof Plan Overall
M-501 - Mechanical - Details
M-601 - Mechanical - Sequences
MP101 - Mechanical Piping Level 01 Plan Overall
MP102 - Mechanical Piping Level 02 Plan Overall
MP103 - Mechanical Piping Level 03 Plan Overall
MP104 - Mechanical Piping Level 04 Plan Overall
ELECTRICAL
E-001 - Electric Cover Sheet

File details come from the government source that posted it. Updated .