2502 Drawings.pdf
PDF 4 MB Posted
- Solicitation number
- 2502
- Issued by
- Kenosha County, Kellnersville Village, Wisconsin
About this file
This is a set of architectural drawings from Kueny Architects for a fuel island project at the Kenosha County Public Safety Building located at 1000 55th Street in Kenosha, Wisconsin. The drawings detail plans for constructing a new fuel island facility including underground fuel tanks (two 10,000 gallon unleaded fuel tanks and one 5,000 gallon diesel fuel tank), fuel dispensers, concrete islands, lighting, electrical work, and a protective canopy structure measuring 25 feet in width with an optional 4-foot extension. The project involves demolition of existing fuel infrastructure and installation of new equipment including fuel management systems, piping, concrete work, and associated site improvements.
The drawings specify technical requirements including 4,000 PSI concrete, detailed reinforcement schedules for footings and piers, electrical panel specifications, and lighting fixtures from Cree (model CPY250). The plans include provisions for integrating with existing generator fuel systems and maintaining building operations during construction. Safety requirements include installation of bollards, emergency shutoffs, and compliance with Class 1 Division 2 hazardous location standards. The drawings are dated December 4, 2024 and marked as "BID SET," indicating these are final construction documents prepared for contractor bidding purposes.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2502 Addendum 1.pdf | ||
| Vendor Responsibility Form Construction.pdf | ||
| 2502 Specifications.pdf | ||
| 2502 Bid Documents.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1.0KUENY ARCHITECTS, LLC
10505 CORPORATE DRIVE - SUITE 100 PLEASANT PRAIRIE, WI 53158 PHONE (262) 857-8101 FAX (262) 857 8103
SITE MAP GENERAL NOTES
1. All concrete to test 4000 psi in 28 days.
2. Verify all dimensions, access, utilities and working conditions in the field.
3. Conform to all applicable codes, ordinances and safety standards.
4. Obtain and pay for all required permits and fees.
5. Notify Architect immediately if work cannot proceed as shown on Drawings or as described in the Specifications.
6. No concrete to be poured without Architect's prior review.
7. All Contractor's to co-operate with all trades, Owner's and Architect's representatives.
8. Leave site clean, neat and free of debris at all times.
9. Each Prime and Sub-contractor is responsible for having read each page of the Specifications, Drawings, Addenda and Change Orders.
10. Guard against interfering with Owner's operations.
11. These Drawings contain no provisions or procedures for on-site safety. Each
Contractor and their employees are responsible to follow all laws and ordinances and provide their own engineering to provide a safe work place.
12. The locations of existing underground utilities, shown on these Drawings, are shown in an approximate way only and have not been independently verified by the Owner or its representatives. The Contractor shall determine the exact location of all existing utilities before commencing work, and agrees to be fully responsible for any and all damages which might be occassioned by the Contractor's failure to exactly locate and preserve any and all underground utilities.
13. Services perform for this project have been conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing in this area under similar budget and time constraints. No warranty, expressed or implied, is made.
MATERIAL INDICATIONS
DRAWING LEGEND
New or Required Point Elevation
Existing Point Elevation
Existing Contours
New or Required Contours
A Grid Lines
3.1 Building Section
Wall Section
Room/Space Number
Door Number
SHEET INDEX
Earth Backfill
Rigid Insulation
Concrete Block
Aluminum
Lumber (Rough)
Steel
Sand Fill
Concrete
Finished Wood
Stone Fill
Plywood
Batt Insulation
4.1
Room 1
101 Interior Elevation
Detail Section
5.1
7.1
CONSULTANTS
5.1
Detail Number
Page Number
Exterior Elevation
2.1
1 Wall Tag
+ 100.0
+ 100.0
+ 100.0
+ 100.0
Kenosha Co. Public Safety
Building
Fuel Island
1000 55th Street Kenosha, WI 53140
December 4, 2024
Kenosha Co. Public Safety Building
Fuel Island
ARCHITECT Kueny Architects 10505 Corporate Drive, Suite 100
(262) 857-8101 Pleasant Prairie, Wisconsin 53158 Architect of Record - Jon P. Wallenkamp
PROJECT
LOCATION
Title
1.0 Title Sheet
ARCHITECTURAL
FI-A101 Site Plans
FI-A102 Architectural Site - Enlarged Plan
FI-A200 Floor Plans
FI-A201 Fuel Island - Exterior Elevations
FI-A301 Fuel Island - Sections, Roof & Lighting Plan - Elec. Panel Schedule
Grand total: 6
BID SET
F �I
C
A
P
Y
F�I� CA��PY
25'�0"
EXISTI�G GE�ERAT�R I�
BASE�E�T
FIE�D VERIFY
EXACT ��CATI��
EXISTI�G VE�T
PIPES (Dashed �"s)
EXISTI�G VAU�T
T� RE�AI�
(11 11 28�14) 5(000 GA�
U�DERGR�U�D DIESE� FUE� TA�)
PER SPECS
(11 11 28�13) 10(000 GA�
U�DERGR�U�D U��EADED FUE�
TA�) PER SPECS
(11 11 28�13) 10(000 GA�
U�DERGR�U�D U��EADED FUE�
TA�) PER SPECS
(11 11 28�16) FUE� CA��PY� FI�A�
DESIG� BY FUE� CA��PY
C��TRACT�R PER SPECS
(01 10 00�04) EXISTI�G GA�VA�I,ED
GRATE @ �V� 1 (12FT AB�VE
BASE�E�T �V�)
(22 01 00�05) T�P �F SAFETY CAP T�
�ATCH EXISTI�G� �ABE� PIPE
I�DICATI�G "DIESE� FUE� ���Y"
(22 01 00�03) �EW 1�102"1 B�AC)
PIPE T� GE�ERAT�R� FIE�D VERIFY
EXACT C��DITI��S� PIPE T�
F����W SI�I�AR R�UTE �F
EXISTI�G PIPES
(22 01 00�04) 1�5"1 B�AC) PIPE FI��
�I�E WITH SAFETY CAP (Red �"�)
(22 01 00�06) PIPE T� PASS THR�UGH
EXISTI�G A�U�I�U� ��UVER A�D
DUCT W�R) AS EXISTI�G� C��P�ETE
SEA� AR�U�D PIPES
(11 11 28�20) I�STA�� H�FF�A�
PE�TAIR B�X F�R FUE� A�AR�
PA�E�� 18x16x10 �E�A 4X
E�C��SURE WITH VIEWI�G WI�D�W
FI�A102
Si4
(01 10 00�05) EXISTI�G E�ECTRIC
PA�E� E�C� USED F�R FUE� IS�A�D
(01 10 00�06) EXISTI�G GAS B�Y
C���U�ICATI��S B�X T� RE�AI�
02 41 00.18
02 41 00.04
02 41 00.12
02 41 00.13
02 41 00.17
02 41 00.19
02 41 00.18
02 41 00.04
02 41 00.18
02 41 00.20
02 41 00.16
02 41 00.04
01 10 00.05
01 10 00.06
01 10 00.07
02 41 00.21
02 41 00.21
1/16" = 1'-0"1 General Floor Plan - Existing & Demo kuenyarch.com ©2024 Kueny Architects L.L.C. - All Rights Reserved
TRUE
NORTH
KEYNOTE LEGEND
SCALE: As indicated
FI-A101Kenosha Co. Public Safety Building - Fuel Island
December 4, 2024
Site P�a s
1000 55th Street Kenosha, WI 53140
1" = 20'-0"2 Architectural Site Plan
01 10 00.04 EXISTING GALVANIZED GRATE @ LVL 1 (12FT ABOVE BASEMENT LVL)
01 10 00.05 EXISTING ELECTRIC PANEL E.C. USED FOR FUEL ISLAND
01 10 00.06 EXISTING GAS BOY COMMUNICATIONS BOX TO REMAIN
01 10 00.07 EXISTING VEDEER-ROOT CONTROLERS TO REMAIN
02 41 00.04 DEMO CONCRETE SLAB. FIELD VERIFY EXISTING CONDITIONS
02 41 00.12 DEMO COMPLETE FUEL ISLAND CONCRETE ISLAND, FUEL DISPENSER
EQUIPMENT AND CANOPY
02 41 00.13 DEMO FUEL ISLAND CANOPY FOOTING
02 41 00.16 REMOVE EXISTING FUEL MASTER MANGAMENT SYSTEM. RE-USE &
RELOCATE PER NEW LAYOUT
02 41 00.17 DEMO DUEL ISLAND CONCRETE BOLLARD
02 41 00.18 DEMO ASPHALT IN THIS AREA
02 41 00.19 DEMO EXISTING UNDERGROUND FUEL TANK AND PIPING
02 41 00.20 REMOVE EXISTING PIPES FROM GENERATOR TO INSIDE BUILDING. CUT PIPE
4 FT INSIDE BUILDING OR NEAREST CONNECTION POINT (FIELD VERIFY)
02 41 00.21 DEMO EXISTING CONDUITS OF FUEL ISLAND CARD READER MANAGAMENT
SYSTEM
11 11 28.13 10,000 GAL UNDERGROUND UNLEADED FUEL TANK PER SPECS
11 11 28.14 5,000 GAL UNDERGROUND DIESEL FUEL TANK PER SPECS
11 11 28.16 FUEL CANOPY. FINAL DESIGN BY FUEL CANOPY CONTRACTOR PER SPECS
11 11 28.20 INSTALL HOFFMAN PENTAIR BOX FOR FUEL ALARM PANEL. 18x16x10 NEMA 4X
ENCLOSURE WITH VIEWING WINDOW
22 01 00.03 NEW 1-1/2"Ø BLACK PIPE TO GENERATOR. FIELD VERIFY EXACT CONDITIONS.
PIPE TO FOLLOW SIMILAR ROUTE OF EXISTING PIPES
22 01 00.04 1.5"Ø BLACK PIPE FILL LINE WITH SAFETY CAP (Red Ln.)
22 01 00.05 TOP OF SAFETY CAP TO MATCH EXISTING. LABEL PIPE INDICATING "DIESEL
FUEL ONLY"
22 01 00.06 PIPE TO PASS THROUGH EXISTING ALUMINUM LOUVER AND DUCT WORK AS
EXISTING. COMPLETE SEAL AROUND PIPES
C Fnc
C FncC
F n c
C F n c
C F n c
C F n c
C F n c
C F n c
C F n c
C F n c
C F n c
C F n c
C F n c
CFnc
CFnc
CFnc CFnc
CFnc CFnc
CFnc CFnc
CFnc
C F n c
C F n c
C F n c
C F n c
C F n c
C F n c
C F n c
CFnc CFncCFnc CFnc CFnc CFnc C F n c
C F n c
C F n c
C F n c
C F n c
C F n c
C Fnc
C Fnc
C Fnc
C F n c
C F n c
C F n c
C F n c
C F n c
C F n c
C F n c
C F n c
C F n c
CFnc CFnc
T H
A V E N
U E
54TH STREET
EXISTING BUILDING
ex mech ex mech
E�ECTRICA� SERVICE
TER�I�ATI�� B�X
WE E�ERGIES
C��CRETE
E�CASED
DUCT BA�)
��R�A� P�WER T�
E�ERGE�CY GE�ERAT�R
20' B�U�DARY
WE E�ERGIES
PAD ��U�T
TRA�SF�R�ER
��R�A� P�WER T�
E�ERGE�CY GE�ERAT�R
20' B�U�DARY
FUE� IS�A�D
20' C�ASS 1 DIV 2
B�U�DARY
GE�ERAT�R
��CATI��
FUEL ISLAND
FI�A201
FI�A201
FI�A201
FI�A201
R
0'
R 2 0' �
03 30 00.21
03 30 00.03
11 11 28.20
DE�IVERY D��R 01 10 00.05
01 10 00.06
01 10 00.07
26 05 00.01
11 11 30.01
11 11 28.12
11 11 28.12
03 30 00.30
03 30 00.30
03 30 00.30
02 41 00.20
22 01 00.02 fleet maintenance storage
26 05 00.02
26 05 00.02
26 05 00.01
21'�0"
REST�RE A�Y �F THE
EXISTI�G DISTURBED
�A�DSCAPED AREA WITH S�D
11 11 28.22
C��STRUCTI�� FE�CE
(31 20 00) CRUSHED ST��E AGGREGATE
VARIES 2'�0" �I�
(07 11 00) 10 �I� VAP�R BARRIER
(03 30 00) REI�F�RCI�G PER SCHEDU�E
(03 30 00) C��CRETE S�AB
�VER�AP REI�F�RCI�G
AT C��STRUCTI�� 6�I�TS
C��STRUCTI�� 6�I�T
1'�0" �I�
(07 11 00) AIR SHIE�D F�ASHI�G
TAPE AT EXTERI�R WA�� �I�E
(03 30 00) 15# FE�T � B��D BREA)ER
C��TR�� 6�I�T
CONCRETE SLAB NOTES
CONCRETE TYPE "B"
6" C��CRETE S�AB � 6 x 6 W 2�9 x W 2�9 WWF w0 10 �I� P��YETHY�E�E VAP�R BARRIER
�VER 6" C��PACTED CRUSHED ST��E
�ue yarch�c�� �2024 �ue y Architects ����C� � A�� Rights Reserved
P�A! !"RTH
KEYNOTE LEGEND
SCALE: As indicated
FI-A102Kenosha Co. Public Safety Building - Fuel Island
December 4, 2024
Architectura� Site � E �arged P�a
1000 55th Street Kenosha, WI 53140
1" = 10'-0"1 Architectural Site Plan
1 1/2" = 1'-0"2 Concrete Slab - Type B
01 10 00.05 EXISTING ELECTRIC PANEL E.C. USED FOR FUEL ISLAND
01 10 00.06 EXISTING GAS BOY COMMUNICATIONS BOX TO REMAIN
01 10 00.07 EXISTING VEDEER-ROOT CONTROLERS TO REMAIN
02 41 00.20 REMOVE EXISTING PIPES FROM GENERATOR TO INSIDE BUILDING. CUT PIPE
4 FT INSIDE BUILDING OR NEAREST CONNECTION POINT (FIELD VERIFY)
03 30 00.03 6" CONCRETE SLAB OVER 6" CRUSHED STONE; SLAB TYPE "B"
03 30 00.21 TYPICAL CONTROL JOINTS
03 30 00.30 ALL NEW CONCRETE TO MATCH ADJACENT GRADE
11 11 28.12 FUEL DISPENSER UNIT PER SPECS
11 11 28.20 INSTALL HOFFMAN PENTAIR BOX FOR FUEL ALARM PANEL. 18x16x10 NEMA 4X
ENCLOSURE WITH VIEWING WINDOW
11 11 28.22 NORTH GENERATOR SHALL HAVE THE MANUF. REP / TECHNICIAN FOR THE
STARTUP OF AS PART OF THIS BID. (CONTACT INFORMATION Brad Fryjoff (bradford.fryjoff@fabickcat.com) / Electric Power Generation Account Manager - Fabick Power Systems / (P) 414-461-9100 / (C) 414-750-6273 / 414-461-8899 fax
11 11 30.01 RE-USE EXISTING MASTER ISLAND KEY READER
22 01 00.02 REPLACE EXISTING BLACK PIPE FROM GENERATOR TO BUILDING. FIELD
VERIFY PIPE WIDTH
26 05 00.01 REPLACE EXISTING CONDUIT AND INSTALL (2) TWO 1-1/2"Ø CONDUITS FOR
FUEL ISLAND LOW VOLTAGE
26 05 00.02 ELECTRIC CONTRACTOR TO INSTALL NEW NEW CONDUITS AND WIRING FOR
NEW FUEL ISLAND. RE-USE EXISTING & SPARE BREAKERS IN PANEL E.C. AS
NEEDED
MECHANICAL
MECHANICAL
D S
L D
S L
D S
L D
S L
D S
L D
S L
D S
L
U L
U L
UL UL
U L
U L
U L
UL ULUL
UL ULUL UL UL UL UL UL
UL ULUL UL UL UL UL UL UL
U L
U L
MECHANICAL
MECHANICAL
D S
L D
S L
D S
L D
S L
D S
L D
S L
D S
L
D S
L
D S
L
FI-A
02 41 00.12
02 41 00.14
25'�6"
E X
IS
T
I� G
F U
E I
S A
D
C A
P Y
EXISTI�G FUE� IS�A�D CA��PY
25'�0"
8'�0
'�0
02 41 00.16
02 41 00.14
21'�0"
02 41 00.15
02 41 00.04
FI-1
FI-1
FI-2
FI-2
EXISTI�G
GE�ERAT�R
��CATI��
02 41 00.18
02 41 00.16
FI-A
F U
E I
S A
D
C A
P Y
FUE� IS�A�D CA��PY
25'�0"
1'�6"23'�0"1'�6"
11 11 28.05
11 11 30.01
11 11 28.05
11 11 28.04
11 11 28.04
11 11 28.07
11 11 28.12
11 11 28.12
11 11 28.19
22 13 16.A6
11 11 28.19
22 13 16.A6
FI�A201
FI�A201
FI�A201
FI�A201
FI�A301
FI�A301
FI-1
FI-1
FI-2
FI-2
ADD T� CA��PY
4'�0"
A�TER�ATE
ADD T� CA��PY
4'�0"
A�TER�ATE
ELECTRIC
GENERATOR
5000 UNDERGROUD
DIESEL TANK
10,000 UNDERGROUD
UNLEADED FUEL TANK
UNLEADED
UNLEADED
DIESEL
UNLEADED
03 30 00.03
03 30 00.03
03 30 00.0303 30 00.03
22 13 16.A7
22 13 16.A2
F�D�
01 10 00.03
01 10 00.03
22 01 00.02
03 30 00.21
03 30 00.21
22 01 00.07
22 01 00.07
22 01 00.08
11 11 28.20
26 05 00.02
26 05 00.01
03 30 00.30
03 30 00.30
03 30 00.30
03 30 00.30
03 30 00.30
26 05 00.02
26 05 00.01
03 30 00.30
11 11 28.21
10,000 UNDERGROUD
UNLEADED FUEL TANK
20'�0"
��RTH GE�ERAT�R
�EW PIPES
�EW DIESE�
TA�)
EXISTI�G CAPPED
PIPES AREA�
SIDEWA�)
EXISTI�G BUI�DI�G
C��CRETE BASE�E�T
WA��
�EW C���ECTI�G
PIPES T� TA�)
EXISTI�G TRE�CH
��RTH GE�ERAT�R
FUE� TA�)
C���ECT �EW PIPES
T� EXISTI�G FUE�
SUPP�Y �I�ES
�EW C��TR�� VA�VES
EXISTI�G FUE� SUPP�Y
�I�ES
�ue yarch�c�� �2024 �ue y Architects ����C� � A�� Rights Reserved
P�A! !"RTH
KEYNOTE LEGEND
SCALE: As indicated
FI-A200Kenosha Co. Public Safety Building - Fuel Island
December 4, 2024
F���r P�a s
1000 55th Street Kenosha, WI 53140
3/16" = 1'-0"1 Floor Plan - Demo 1/4" = 1'-0"2 Floor Plan
01 10 00.03 EXISTING BOLLARDS TO REMAIN
02 41 00.04 DEMO CONCRETE SLAB. FIELD VERIFY EXISTING CONDITIONS
02 41 00.12 DEMO COMPLETE FUEL ISLAND CONCRETE ISLAND, FUEL DISPENSER EQUIPMENT AND CANOPY
02 41 00.14 DEMO CONCRETE - REMOVE EXISTING UNDERGROUND FUEL TANK & PIPING
02 41 00.15 DEMO EXISTING UNDERGROUND OIL TANK. DEMO ASPHALT/CONCRETE AS NEEDED. FIELD VERIFY ALL
CONDITIONS.
02 41 00.16 REMOVE EXISTING FUEL MASTER MANGAMENT SYSTEM. RE-USE & RELOCATE PER NEW LAYOUT
02 41 00.18 DEMO ASPHALT IN THIS AREA
03 30 00.03 6" CONCRETE SLAB OVER 6" CRUSHED STONE; SLAB TYPE "B"
03 30 00.21 TYPICAL CONTROL JOINTS
03 30 00.30 ALL NEW CONCRETE TO MATCH ADJACENT GRADE
11 11 28.04 4" STAINLESS STEEL U-BOLLARD. TYP. @ ENDS OF FUEL ISLAND BY FUEL ISLAND CONTRACTOR
11 11 28.05 FUEL CANOPY STRUCTURAL COLUMN PER FUEL ISLAND CONTRACTOR
11 11 28.07 CONCRETE FUEL ISLAND W/ STAINLESS STEEL EDGE FORM. VARIES HEIGHT PER LOCATION (6" MIN)
11 11 28.12 FUEL DISPENSER UNIT PER SPECS
11 11 28.19 FUEL ISLAND ALUMINUM DOWNSPOUT BY FUEL ISLAND CONTRACTOR
11 11 28.20 INSTALL HOFFMAN PENTAIR BOX FOR FUEL ALARM PANEL. 18x16x10 NEMA 4X ENCLOSURE WITH VIEWING
WINDOW
11 11 28.21 COMPLETE STARTUP FOR ADDITIONAL DISPENSING UNITS
11 11 30.01 RE-USE EXISTING MASTER ISLAND KEY READER
22 01 00.02 REPLACE EXISTING BLACK PIPE FROM GENERATOR TO BUILDING. FIELD VERIFY PIPE WIDTH
22 01 00.07 EXISTING FUEL PUMP AND FUEL LINE TO REMAIN
22 01 00.08 CONNECT EXISTING FUEL LINE TO NEW UNDERGROUND DIESEL FUEL TANK
22 13 16.A2 FLOOR DRAIN
22 13 16.A6 6" STORM PIPE. CONNECT TO NEAREST CATCH BASIN
22 13 16.A7 3" DRAIN PIPE. CONNECT TO NEAREST CATCH BASIN
26 05 00.01 REPLACE EXISTING CONDUIT AND INSTALL (2) TWO 1-1/2"Ø CONDUITS FOR FUEL ISLAND LOW VOLTAGE
26 05 00.02 ELECTRIC CONTRACTOR TO INSTALL NEW NEW CONDUITS AND WIRING FOR NEW FUEL ISLAND. RE-USE
EXISTING & SPARE BREAKERS IN PANEL E.C. AS NEEDED
3/16" = 1'-0"3 New Piping Schematic
�EVE� 1
0'�0"
B" Ca �py
16'�0"
T" Ca �py
18'�6"
T" F��ti g
�14'�0"
A�TER�ATE
4'�0"
CA��PY � BASE BID
25'�0"
A�TER�ATE
4'�0"
2'�6" 20'�0" 2'�6"
11 11 28.02
11 11 28.16
11 11 28.19
11 11 28.05
11 11 28.12
11 11 28.11
11 11 30.01
11 11 28.07
11 11 28.17
11 11 28.05
11 11 28.12
11 11 28.07
11 11 28.17
FI�A301FI-1 FI-2
11 11 28.1011 11 28.11
11 11 28.01
CA��PY w0 A�TER�ATE
33'�0"
11 11 28.10
3'�0"13'�2"3'�0"
11 11 28.1311 11 28.13
(0 g a T
A
3'�5"13'�2"3'�5"
�EVE� 1
0'�0"
B" Ca �py
16'�0"
T" Ca �py
18'�6"
FI-A
T" F��ti g
�14'�0"
25'�0"
3'�2"
FI�A301
11 11 28.16
11 11 28.19
11 11 28.05
11 11 28.12
11 11 28.11
11 11 28.08
11 11 28.17
11 11 28.02
11 11 28.01
8'�6" 8'�6"
17'�0"
�EVE� 1
0'�0"
B" Ca �py
16'�0"
T" Ca �py
18'�6"
T" F��ti g
�14'�0"
A�TER�ATE
4'�0" 2'�6" 20'�0" 2'�6"
A�TER�ATE
4'�0"
CA��PY � BASE BID
25'�0"
11 11 28.02
11 11 28.05
11 11 28.12
11 11 28.11
11 11 30.01
11 11 28.07
11 11 28.02
11 11 28.05
11 11 28.12
11 11 28.11
11 11 28.07
11 11 28.17
11 11 28.16
FI�A301
FI-1FI-2
11 11 28.11
11 11 28.10
CA��PY w0 A�TAR�ATE
33'�0"
11 11 28.10
(0 g a F
U E
T
A
�EVE� 1
0'�0"
B" Ca �py
16'�0"
T" Ca �py
18'�6"
FI-A
T" F��ti g
�14'�0"
12'�6" 12'�6"
25'�0"
3'�0"
11 11 28.02
11 11 28.12
11 11 28.05
11 11 28.19
11 11 28.11
11 11 28.07
3'�2"
FI�A301
11 11 28.17
11 11 28.01
17'�0"
7'�6" 2'�0" 7'�6"
BASE P�ATE A�D C��U��
PER CA��PY DESIG�
1'�0" 1'�0"
PIER
2'�0"
P
IE
R
VERTICA� REI�F�RCI�G
A�D TIES PER SCHEDU�E
2" C�VER �I�I�U�
C��CRETE PIER
(8) #8 VERTICA� w0
#3 TIES @ 16" ��C�
FI�A201
Si4
14'�0"
7'�0" 7'�0"
TYP F""TI!G � 17' x 14' x 18"
REI�F�RCI�G<
(11) #6 BARS ���G
(14) #6 BARS TRA�S
T�P & B�TT��
�ue yarch�c�� �2024 �ue y Architects ����C� � A�� Rights Reserved
P�A! !"RTH
KEYNOTE LEGEND
SCALE: As indicated
FI-A201Kenosha Co. Public Safety Building - Fuel Island
December 4, 2024
Fue� Is�a d � Exteri�r E�evati� s
1000 55th Street Kenosha, WI 53140
11 11 28.01 ROOF DRAIN PER FUEL ISLAND CONTRACTOR; TIE ROOF DRAIN TO
ALUMINUM DOWNSPOUT INTERNAL IN MASONRY COLUMN
11 11 28.02 ALUMINUM PANEL FASCIA PER FUEL ISLAND CONTRACTOR; PANEL TO
MATCH BUILDING 01 PANEL
11 11 28.05 FUEL CANOPY STRUCTURAL COLUMN PER FUEL ISLAND CONTRACTOR
11 11 28.07 CONCRETE FUEL ISLAND W/ STAINLESS STEEL EDGE FORM. VARIES HEIGHT
PER LOCATION (6" MIN)
11 11 28.08 6" CONCRETE CURB PER FUEL ISLAND CONTRACTOR REQUIREMENTS
11 11 28.10 UNLEADED FUEL DISPENSER
11 11 28.11 DIESEL FUEL DISPENSER
11 11 28.12 FUEL DISPENSER UNIT PER SPECS
11 11 28.13 10,000 GAL UNDERGROUND UNLEADED FUEL TANK PER SPECS
11 11 28.16 FUEL CANOPY. FINAL DESIGN BY FUEL CANOPY CONTRACTOR PER SPECS
11 11 28.17 FUEL CANOPY FOOTING. SEE DETAILS 5/FI-A201 and 6/FI-A201 SHOWING SIZE
AND REINFORCING REQUIREMENTS
11 11 28.19 FUEL ISLAND ALUMINUM DOWNSPOUT BY FUEL ISLAND CONTRACTOR
11 11 30.01 RE-USE EXISTING MASTER ISLAND KEY READER
1/4" = 1'-0"2 Elevation - South 1/4" = 1'-0"1 Elevation - West
1/4" = 1'-0"4 Elevation - North
1/4" = 1'-0"3 Elevation - East
1 1/2" = 1'-0"5 Pier Reinforcing Detail
1/4" = 1'-0"6 Typ. Footing Detail
FI-A
FI�A201
FI�A201
FI�A201
FI�A201
FI�A301
FI�A301
FI-1
FI-1
FI-2
FI-2
108" 0 1'�0"104" 0 1'�0"
A�TER�ATE
4'�0"
CA��PY � BASE BID
25'�0"
A�TER�ATE
4'�0"
CA��PY w0 A�TER�ATE
33'�0"
C A
P Y
11 11 28.01
11 11 28.16
11 11 28.02
�EVE� 1
0'�0"
B" Ca �py
16'�0"
T" Ca �py
18'�6"
FI�A301
FI-1 FI-2
A�TER�ATE
4'�0"
FUE� CA��PY � BASE BID
25'�0"
A�TER�ATE
4'�0"
FUE� CA��PY w0 A�TER�ATE
33'�0"
11 11 28.16
11 11 28.16
11 11 28.19
11 11 28.05
11 11 28.12
11 11 28.11
11 11 28.10
11 11 28.10
11 11 28.12
11 11 28.11
11 11 28.1111 11 30.01
�EVE� 1
0'�0"
B" Ca �py
16'�0"
T" Ca �py
18'�6"
FI-A
T" F��ti g
�14'�0"
FI�A301
11 11 28.16
11 11 28.01
11 11 28.02
11 11 28.05
11 11 28.19
11 11 28.11
11 11 28.12
11 11 28.08
25'�0"
11 11 28.13
11 11 28.17
FI-A
FI�A201
FI�A201
FI�A201
FI�A301
FI�A301
FI-1
FI-1
FI-2
FI-2
24'�0"
A�TER�ATE
4'�0"
CA��PY � BASE BID
25'�0"
A�TER�ATE
4'�0"
11 11 28.16
11 11 28.12
11 11 28.05
11 11 28.1911 11 28.19
11 11 28.05
11 11 28.16
��2 ��2 ��2
��2 ��2 ��2
E�ECTRICA� !"TES
• E�ECTRICA� C��TRACT�R T� FIE�D VERIFY A�� CIRCUITS
• RE�USE A�� EXISTI�G CIRCUITS BREA)ERS BEI�G USED F�R THE FUE� IS�A�D A�D SPARE CIRCUITS AS �EEDED�
• E�ECTRIC C��TRACT�R T� I�STA�� A�� �EW C��DUITS A�D �EW WIRI�G F�R �EW FUE� IS�A�D�
�ue yarch�c�� �2024 �ue y Architects ����C� � A�� Rights Reserved
KEYNOTE LEGEND
SCALE: As indicated
FI-A301Kenosha Co. Public Safety Building - Fuel Island
December 4, 2024
Fue� Is�a d � Secti� s4 R��f & �ighti g P�a � E�ec� Pa e� Schedu�e
1000 55th Street Kenosha, WI 53140
1/4" = 1'-0"1 Fuel Island Roof Plan
1/4" = 1'-0"4 Section - E/W North
1/4" = 1'-0"3 Section - N/S East
11 11 28.01 ROOF DRAIN PER FUEL ISLAND CONTRACTOR; TIE ROOF DRAIN TO
ALUMINUM DOWNSPOUT INTERNAL IN MASONRY COLUMN
11 11 28.02 ALUMINUM PANEL FASCIA PER FUEL ISLAND CONTRACTOR; PANEL TO
MATCH BUILDING 01 PANEL
11 11 28.05 FUEL CANOPY STRUCTURAL COLUMN PER FUEL ISLAND CONTRACTOR
11 11 28.08 6" CONCRETE CURB PER FUEL ISLAND CONTRACTOR REQUIREMENTS
11 11 28.10 UNLEADED FUEL DISPENSER
11 11 28.11 DIESEL FUEL DISPENSER
11 11 28.12 FUEL DISPENSER UNIT PER SPECS
11 11 28.13 10,000 GAL UNDERGROUND UNLEADED FUEL TANK PER SPECS
11 11 28.16 FUEL CANOPY. FINAL DESIGN BY FUEL CANOPY CONTRACTOR PER SPECS
11 11 28.17 FUEL CANOPY FOOTING. SEE DETAILS 5/FI-A201 and 6/FI-A201 SHOWING SIZE
AND REINFORCING REQUIREMENTS
11 11 28.19 FUEL ISLAND ALUMINUM DOWNSPOUT BY FUEL ISLAND CONTRACTOR
11 11 30.01 RE-USE EXISTING MASTER ISLAND KEY READER
1/4" = 1'-0"2 Fuel Island Canopy - Lighting Plan
LIGHT FIXTURE SCHEDULE
TYPE 7A!UFACTURER SERIES "RDER I!F"R7ATI"! !"TE
��1 CREE CPY250 4� 40)9 F U� D� �� A�� THE TI�E
��2 CREE CPY250 4� 40)9 F U� D� �� WITH �CC� SE�S�R
Electric Panel Schedule
| Sheets |
| 1.0 - Title Sheet |
| FI-A101 - Site Plans |
| FI-A102 - Architectural Site - Enlarged Plan |
| FI-A200 - Floor Plans |
| FI-A201 - Fuel Island - Exterior Elevations |
| FI-A301 - Fuel Island - Sections, Roof & Lighting Plan - Elec. Panel Schedule |
File details come from the government source that posted it. Updated .