2500303-DR03 ADDENDUM A 2026-04-08.pdf
PDF 1 MB Posted
- Attached to
- Toilet Room/Art Room Renovation
- Solicitation number
- RFP WMAA 260000001705 2
- Issued by
- Ottawa County, Michigan
About this file
This Addendum A document is issued by Ghafari Associates on behalf of West Michigan Academy of Arts and Academics (WMAAA) for the Pre-K and Art Room Improvements project located at 17350 Hazel Street, Spring Lake, Michigan. The project involves facility improvements including the addition of pre-kindergarten toilets, sink cabinets, and an exterior egress door with concrete stoop; relocation of playground equipment; installation of a unisex toilet; and replacement of art room sinks and cabinets. The scope of work encompasses mechanical heating and ventilation modifications for toilet room exhaust, plumbing modifications including new underground sanitary lines and art sink installations with sediment separator traps, electrical modifications for lighting and fire alarm systems, and security modifications coordinated with design-build contractors. The addendum was issued on April 8, 2026, as Document Release 03 following the initial Issue for Bids (March 24, 2026) and Issue for Permit (March 24, 2026), superseding all prior document releases.
The addendum includes revisions to structural and architectural sheets addressing coordination with existing grade, updated millwork details requiring PVC edgebanding for door and drawer fronts, and modifications to the exterior stoop detail to provide handrails, trench drain, stairs, and sidewalk connections. The document clarifies that the project is not federally funded and requires compliance with State of Michigan prevailing wage rates rather than Federal Davis-Bacon Act requirements, with contractors obligated to pay construction mechanics not less than prevailing rates in the locality where work is performed. The contractor shall indemnify and hold harmless the owner, architect, consultants, agents, and employees against claims, damages, losses, and expenses arising from performance of the work. Plumbing, mechanical, electrical, and fire alarm system engineering are design-build responsibilities assigned to the contractor, with required MEP and fire alarm drawings to be provided and coordinated with the city for permit submissions.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ghafari Project Number: 2500303 WMAAA TLT-ART RMS Document Release 03 – ADDENDUM A Date: 04/08/26
INDEMNIFICATION:
The Contractor shall indemnify and hold Harmless the Owner, Architect, Architect’s consultants, agents and employees of any for them and against claims, damages, losses and expenses including, but not limited to attorneys’ fees, arising out of or resulting from performance of the Work.
Revision Date: 08.15.2019 Page 1 AE-DES-F-202
PROJECT NAME: Pre-K and Art Room Improvements OWNER / CLIENT: West Michigan Academy of
Arts and Academics
ISSUE DESCRIPTION: Addendum A PROJECT MGR: A. Nelson
INSTRUCTIONS
1. These documents are released by the Architect / Engineer for:
Review
Permits
Bid
Construction
X Modification of Prior Document Release (Addendum / Bulletin / Revision)
Record
Other
2. Documents: Documents included in this Release supersede and replace those of prior releases.
3. Do not proceed with Work until authorized
4. Immediately notify the following entity of Work presently underway that is affected by this Release.
X Architect / Engineer
Construction Manager
5. Drawing revisions are clouded.
6. Specifications, Bidding Requirements, and Contracting Conditions revisions show added text bold and deleted text struck through. A vertical line in the page margin appears next to each revision.
7. If a bid is requested, comply with the requirements of the Bidding Requirements or follow the procedures used by the
Construction Manager, as applicable.
8. If a price quotation is requested, quote items as listed in the "Quotation Breakdown" at the end of this release form or in accordance with the instructions of the Construction Manager, as applicable. Items are a synopsis of the work required, not an exhaustive list; include all incidental work necessary to complete each item.
Documents listed are applicable to this Document Release:
PROJECT MANUAL
Specification Sections accompanying and forming part of this issue:
X None
See Master Specification Index
DRAWINGS
Drawings accompanying and forming part of this issue:
None
X See Master Drawing Index
ATTACHMENTS
Attachments accompanying and forming part of this issue:
X None
As follows:
The Contractor shall indemnify and hold Harmless the Owner, Architect, Architect’s consultants, agents and employees of any for them and against claims, damages, losses and expenses including, but not limited to attorneys’ fees, arising out of or resulting from performance of the Work.
Revision Date: 08.15.2019 Page 2 AE-DES-F-202
DESCRIPTION OF WORK
In general terms, the work of this package includes Addendum items for the WMAAA Pre-K and Art Room Improvements project located in Spring Lake, MI.
THE DETAILED SCOPE OF WORK IS AS FOLLOWS:
CHANGES TO THE WORK
GENERAL:
• Sheet # GO0-00-00 – Cover Sheet (reissued) o Refer to revised sheet index indicating amended drawings.
STRUCTURAL:
• Sheet #SF0-01-02 (reissued) o Revised supported stoop detail 3/SF0-01-02 and added detail 4/SF0-01-02 to address coordination with existing grade.
ARCHITECTURAL:
• Sheet #AE1-01-01 (reissued) o Updated General Notes and millwork details to indicate PVC edgebanding required for millwork door and drawer fronts.
o Refer to demolition key notes and demolition plan for clarification of existing residential type exhaust fan in Toilet #102 upper gypsum board ceiling to be replaced; roof vent cap may remain for reuse or replace if not in good working condition.
o Refer to Floor Plan Pre-K and revised Key Note 11: Revised supported stoop to provide handrails, trench drain, stair and short connecting sidewalk to address grade elevation above finished floor, and restoration of grading and wood chips.
o Added Detail 9 – Handrail Detail as provided.
BIDDER QUESTIONS:
The following are questions received from potential bidders, followed by responses provided to present clarification to the bid documents.
“Question #1.” Is the prevailing wage rates the State required local rates or Federal Davis-Bacon Act wage requirements?
Response #1. Contractor to comply with the State of Michigan prevailing wage rates. The project is not federally funded. Refer to the
State of Michigan official rate schedules that can be found on the Labor and Economic Opportunity (LEO) website. The selected contractor’s contract shall include the following contract language: “The wages and fringe benefits paid to construction mechanics
[…] by the contractor and all subcontractors must not be less than the prevailing rates in the locality where the work is performed.“.
END OF DOCUMENT RELEASE
The Contractor shall indemnify and hold Harmless the Owner, Architect, Architect’s consultants, agents and employees of any for them and against claims, damages, losses and expenses including, but not limited to attorneys’ fees, arising out of or resulting from performance of the Work.
Revision Date: 08.15.2019 Page 3 AE-DES-F-202
DISTRIBUTION LIST
Owner: WMAAA Full Size Half Size Specifications Electronic
Maggie Malone x
Ghafari Associates, LLC
Adam Nelson x
Other:
Potential Bidders x
The Contractor shall indemnify and hold Harmless the Owner, Architect, Architect’s consultants, agents and employees of any for them and against claims, damages, losses and expenses including, but not limited to attorneys’ fees, arising out of or resulting from performance of the Work.
Revision Date: 08.15.2019 Page 4 AE-DES-F-202
LIST OF DOCUMENT RELEASES
DATE DOC REL DESCRIPTION
03/24/26 01 ISSUE FOR BIDS (IFB)
03/24/26 02 ISSUE FOR PERMIT (IFP)
04/08/26 03 ADDENDUM A
DN DN
DN
RIDGE AVE
U S-
ZINNIE LN
HAZEL S
T
17350 HAZEL STREET
SPRING LAKE, MI 49456
● ISSUED
○ ISSUED FOR REFERENCE ONLY
INDEX LEGEND
ART-1
ART-2
SENSORY ROOM
PRE-KINDERGARTEN
AND TOILET ROOMS
A.
B.
C.
NOTE:
GENERAL LOCATION OF WORK SCOPE AREAS CIRCLED.
NOT ALL WORK SCOPE MAY BE CONTAINED WHERE SHOWN; COORDINATE ALL WORK
AND BUILDING SYSTEMS REQUIRED FOR THE PROJECT.
REFER TO ALL CONTRACT DOCUMENTS, INCLUDING DESIGN-BUILD REQUIREMENTS.
PROJECT IMAGE PROJECT TEAM
LOCATION MAP
N.T.S.
PROJECT DESCRIPTION LOCATION MAPPROJECT NAME AND ADDRESS
FACILITY IMPROVEMENTS TO ADD PRE-KINDERGARTEN TOILETS,
SINK CABINETS, AND EXTERIOR EGRESS DOOR, CONCRETE STOOP,
AND PLAYGROUND RELOCATED EQUIPMENT, ADD A UNISEX TOILET
FOR GENERAL USE, AND REPLACEMENT OF ART ROOM SINKS AND
CABINETS.
MECHANICAL HEATING AND VENTILATION MODIFICATIONS,
INCLUDING TOILET ROOM EXHAUST, COORDINATED WITH DESIGN-
BUILD MECHANICAL CONTRACTOR.
PLUMBING MODIFICATIONS, INCLUDING NEW UNDERGROUND
SANITARY, ART SINKS WITH A SEDIMENT SEPARATOR TRAP, AND
HOT AND COLD WATER LINES, COORDINATED WITH DESIGN-BUILD
PLUMBING CONTRACTOR.
ELECTRICAL MODIFICATIONS, INCLUDING LIGHTING, EMERGENCY
LIGHTING, FIRE ALARM, AND POWER, COORDINATED WITH THE
DESIGN-BUILD ELECTRICAL CONTRACTOR.
SECURITY MODIFICATIONS, INCLUDING BURGLAR ALARM CONTACTS,
WIRING, AND CONTROLS, BY DESIGN-BUILD CONTRACTOR;
SUBCONTRACT OWNER'S SECURITY VENDOR.
CONTRACTOR TO PROVIDE MEP/FIRE ALARM/SECURITY DRAWINGS.
CITY SUBMITTALS
1.
1.
2.
3.
4.
LIST OF CITY SUBMITTALS
PERMITS
LIST OF DEFERRED CITY SUBMITTALS
PLUMBING ENGINEERING IS DESIGN-BUILD BY CONTRACTOR.
MECHANICAL ENGINEERING IS DESIGN-BUILD BY CONTRACTOR.
ELECTRICAL ENGINEERING IS DESIGN-BUILD BY CONTRACTOR
FIRE ALARM SYSTEM ENGINEERING IS DESIGN-BUILD BY
CONTRACTOR.
PROJECT INFORMATION
G H
AF
AR
I A
SS
O C
IA
TE
S
TEL +1.616.771.0909
37 OTTAWA AVENUE NW
SUITE 700
www.ghafari.com
GRAND RAPIDS, MI 49503-2900 USA
ARCHITECT
STRUCTURAL ENGINEER
4/ 7/
:5
6:
P M
PROJECT NUMBER: 2500303
ISSUED FOR: ADDENDUM A
ISSUE DATE: 04/08/26
Pre-K and Art Room Improvements 17350 Hazel Street
Spring Lake, MI 49456
00-0-02
DRAWING INDEX - PROJECT
/2
4/
D
O C
R
EL
- I
FB
/2
4/
D
O C
R
EL
- I
FP
/0
8/
D
O C
R
EL
- A D
D
EN
D U
M A
SHEET # SHEET TITLE
00 GENERAL INFORMATION
● ● ● GO0-00-00 COVER SHEET
● ● GO0-00-01 GENERAL INFORMATION PROJECT INFORMATION
● ● GO0-00-02 GENERAL INFORMATION PROJECT INFORMATION AND CODE SUMMARY
60 STRUCTURAL
● ● SF0-01-01 STRUCTURAL NOTES
● ● ● SF0-01-02 SPECIAL INSPECTIONS AND STRUCTURAL DETAILS
70 ARCHITECTURAL
● ● AO0-00-01 ARCHITECTURAL GENERAL INFORMATION PROJECT NOTES
● ● AO0-00-02 ARCHITECTURAL GENERAL INFORMATION PROJECT NOTES
● ● AO0-00-03 ARCHITECTURAL GENERAL INFORMATION PROJECT NOTES
73 ARCHITECTURAL ELEMENTS
● ● ● AE1-01-01 ARCHITECTURAL FLOOR AND CEILING PLANS, INTERIOR ELEVATIONS
● ● AE7-00-01 ARCHITECTURAL SCHEDULES AND DETAILS
SCALE:
NORTH
1/32" = 1'-0"
COMPOSITE WORK SCOPE LOCATION PLAN
1. SPECIAL INSPECTION SHALL MEET THE REQUIREMENTS OF THE IBC CHAPTER 17. THE OWNER SHALL
ENGAGE AN APPROVED AGENCY TO PERFORM THIS SERVICE.
2. PROJECT DESIGN BASIS RELEVANT TO SPECIAL INSPECTION REQUIREMENTS:
• SEISMIC DESIGN CATEGORY (SDC) IS B
• WIND EXPOSURE CATEGORY IS C
• THE NOMINAL DESIGN WIND SPEED IS 114 MPH
• RISK CATEGORY IS III.
3. SPECIAL INSPECTION FOR STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH:
• AISC 360, CHAPTER N
4. SPECIAL INSPECTION OF MASONRY SHALL BE IN ACCORDANCE WITH TMS402/602
• PROVIDE LEVEL 2 QUALITY ASSURANCE (TMS 402 TABLE 3.1.)
5. SPECIAL INSPECTION OF CONCRETE CONSTRUCTION SHALL BE AS INDICATED IN TABLE 1705.3
(PROVIDED ON THIS SHEET) IN ACCORDANCE WITH THE PROVISIONS OF SECTION 1705.3.
6. OWNER SHALL ENGAGE A REGISTERED DESIGN PROFESSIONAL FOR VISUAL OBSERVATIONS OF THE
STRUCTURAL SYSTEM FOR GENERAL CONFORMANCE TO THE CONSTRUCTION DOCUMENTS.
7. SPECIAL INSPECTION OF EXTERIOR INSULATION AND FINISH SYSTEMS IN ACCORDANCE WITH
SECTION 1705.16
1. INSPECTION OF REINFORCING STEEL, INCLUDING
PRESTRESSING TENDONS, AND PLACEMENT
- X
2. INSPECTION OF REINFORCING STEEL WELDING:
- X
3. INSPECTION OF ANCHORS CAST IN CONCRETE X
CONTINUOUS
DURING TASK
PERIODIC
DURING TASK
4. INSPECTION OF ANCHOR POST-INSTALLED IN HARDENED
CONCRETE MEMBERS
5. VERIFYING USE OF REQUIRED DESIGN MIX. - X
6. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS
FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT
TESTS, AND DETERMINE THE TEMPERATURE OF CONCRETE
X -
7. INSPECTION OF CONCRETE AND SHOTCRETE
PLACEMENT FOR PROPER APPLICATION TECHNIQUES.
8. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING
TEMPERATURE AND TECHNIQUES.
X -
- X
9. INSPECTION FOR PRESTRESSED CONCRETE:
A. APPLICATION OF PRESTRESSING FORCES
B. GROUTING OF BONDED PRESTRESSING TENDONS
X -
X -
10. ERECTION OF PRECAST CONCRETE MEMBERS.
12. INSPECT FORMWORK FOR SHAPE, LOCATION AND
DIMENSIONS OF CONCRETE MEMBER BEING FORMED.
11. VERIFICATION OF IN-SITU CONCRETE STRENGTH, PRIOR TO
STRESSING OF TENDONS IN POST-TENSIONED CONCRETE
AND PRIOR TO REMOVAL OF SHORES AND FORMS
FROM BEAMS AND STRUCTURAL SLABS.
- X
- X
- X
REFERENCED
STANDARD
IBC
REFERENCE
ACI 318:
CH. 20, 25.2, 25.3,
26.6.1-26.6.3 1908.4
AWS D1.4
ACI 318: 26.6.4
ACI 318: 17.8.2
ACI 318:
17.8.2.4
ACI 318:
CH. 19, 26.4.3, 26.4.4
1904.1, 1904.2, 1908.2, 1908.3
ASTM C 172
ASTM C 31
ACI 318: 26.5, 26.12
1908.10
ACI 318: 26.5 1908.6, 1908.7,
1908.8
ACI 318:
26.5.3-26.5.5 1908.9
ACI 318: 26.10 -
ACI 318: 26.8
ACI 318: 26.10.2
ACI 318: 26.10.1b
- X
X -
A. WELDABILITY OF REINFORCING BARS OTHER
THAN ASTM A 706
B. INSPECT SINGLE-PASS FILLET WELDS (MAXIMUM 5/16")
C. INSPECT ALL OTHER WELDS NOT LISTED IN TABLE
1705.3 ITEM 2B
ACI 318: 17.8.2
-X
X-
A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR
UPWARDLY INCLINED ORIENTATIONS TO RESIST
SUSTAINED TENSION LOADS
B. MECHANICAL ANCHORS AND ADHESIVE ANCHORS
NOT DEFINED IN TABLE 1705.3 ITEM 4A
ACI 318: 26.9 -
SPECIAL INSPECTIONS AND TESTS
OF CONCRETE CONSTRUCTION
(IBC TABLE 1705.3)
INSPECTION TASK
1. AS MASONRY CONSTRUCTION BEGINS, VERIFY THAT THE FOLLOWING ARE IN COMPLIANCE:
LEVEL 1
NRa. PROPORTIONS OF SITE-PREPARED MORTAR
MASONRY SPECIAL INSPECTION REQUIREMENTS MINIMUM (TMS 602 TABLE 4)
FREQUENCY (a) REFERENCE FOR CRITERIA
LEVEL 2 LEVEL 3 TMS 402 TMS 602
P P ART. 2.1, 2.6 A, & 2.6 C
NRb. GRADE AND SIZE OF PRESTRESSING TENDONS AND ANCHORAGES P P ART. 2.4, B & 2.4 H
ART. 3.4 & 3.6 A
ART. 3.6 B
ART. 2.1 C.1
ART. 1.6 D
P
P
C
C
P
P
C(b)/P(c)
P
NR
NR
NR
NR
c. GRADE, TYPE AND SIZE OF REINFORCEMENT, CONNECTORS, ANCHOR BOLTS,AND
PRESTRESSING TENDONS AND ANCHORAGES
d. PRESTRESSING TECHNIQUE
e. PROPERTIES OF THIN-BED MORTAR FOR AAC MASONRY
f. SAMPLE PANEL CONSTRUCTION
2. PRIOR TO GROUTING, VERIFY THAT THE FOLLOWING ARE IN COMPLIANCE:
NRa. GROUT SPACE P C ART. 3.2 D & 3.2 F
NRb. PLACEMENT OF PRESTRESSING TENDONS AND ANCHORAGES P P ART. 2.4,& 3.6
ART. 3.2 E & 3.4
ART. 2.6 B & 2.4 G.1.b
C
P
P
P
NR
NR
c. PLACEMENT OF REINFORCEMENT, CONNECTOR, AND ANCHOR BOLTS
d. PROPORTIONS OF SITE-PREPARED GROUT AND PRESTRESSING GROUT FOR BONDED TENDONS
3. VERIFY COMPLIANCE OF THE FOLLOWING DURING CONSTRUCTION:
NRa. MATERIALS AND PROCEDURES WITH THE APPROVED SUBMITTALS P P ART. 1.5
NRb. PLACEMENT OF MASONRY UNITS AND MORTAR JOINT CONSTRUCTION P P ART. 3.3 B
ART. 3.3 FP
C
P
P
NR
NR
c. SIZE AND LOCATION OF STRUCTURAL MEMBERS
d. TYPE, SIZE, AND LOCATION OF ANCHORS, INCLUDING OTHER DETAILS OF ANCHORAGE
OF MASONRY TO STRUCTURAL MEMBERS, FRAMES, OR OTHER CONSTRUCTION
e. WELDING OF REINFORCEMENT
f. PREPARATION, CONSTRUCTION, AND PROTECTION OF MASONRY DURING COLD WEATHER
(TEMPERATURE BELOW 40°F (4.4°C)) OR HOT WEATHER (TEMPERATURE ABOVE 90°F(32.2°C))
g. APPLICATION AND MEASUREMENT OF PRESTRESSING FORCE
I. PLACEMENT OF AAC MASONRY UNITS AND CONSTRUCTION OF THIN-BED MORTAR JOINTS
h. PLACEMENT OF GROUT AND PRESTRESSING GROUT FOR BONDED TENDONS IS IN COMPLIANCE
NR
NR
NR
NR
NR
NR
C
P
C
C
P
C(b)/P(c)
C
P
C
C
C
C4. OBSERVE PREPARATION OF GROUT SPECIMENS, MORTAR SPECIMENS, AND/OR PRISMS
SEE. 10.8 & 10.9
SEE. 6.1, 6.3.1,
6.3.6, & 6.3.7
SEE. 1.2.1(e), 6.2.1, & 6.3.1
SEE. 6.1.6.1.2
ART. 1.8 C & 1.8 D
ART. 3.6 B
ART. 3.5 & 3.6 C
ART. 3.3 B.9
& 3.3 F.1.b
ART. 1.4 B.2.a.3,
1.4 B.2.b.3,
1.4 B.2.c.3,
1.4 B.3, & 1.4 B.4
(a) FREQUENCY REFERS TO THE FREQUENCY OF INSPECTION, WHICH MAY BE CONTINUOUS DURING THE LISTED TASK OR PERIODICALLY DURING THE LISTED TASK, AS DEFINED IN THE TABLE.
NR=NOT REQUIRED, P=PERIODIC, C=CONTINUOUS
(b) REQUIRED FOR THE FIRST 5000 SQUARE FEET (465 SQUARE METERS) OF AAC MASONRY.
(c) REQUIRED AFTER THE FIRST 5000 SQUARE FEET (465 SQUARE METERS) OF AAC MASONRY.
TESTING OF STRUCTURAL STEEL (IBC 1705.2.1)
AISC 360 TABLE N5.4-1- INSPECTION TASKS PRIOR TO WELDING
SPECIAL INSPECTIONS AND NON DESTRUCTIVE
VERIFICATION AND INSPECTION QUALITY CONTROL
1. WELDING PROCEDURE SPECIFICATIONS (WPSs) AVAILABLE. P
2. MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE.
3. MATERIAL IDENTIFICATION. (TYPE/GRADE)
4. WELDER IDENTIFICATION SYSTEM¹
5. FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY)
• JOINT PREPARATION
• DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL)
• CLEANLINESS (CONDITION OF STEEL SURFACES)
• TACKING (TACK WELD QUALITY AND LOCATION)
• BACKING TYPE AND FIT ( IF APPLICABLE)
6. CONFIGURATION AND FINISH OF ACCESS HOLES.
7. FIT-UP OF FILLET WELDS
• DIMENSIONS (ALIGNMENT, GAPS AT ROOT)
• CLEANLINESS (CONDITION OF STEEL SURFACES)
• TACKING (TACK WELD QUALITY AND LOCATION)
8. CHECK WELDING EQUIPMENT
¹ THE FABRICATOR OR ERECTOR, AS APPLICABLE, SHALL MAINTAIN A SYSTEM BY WHICH A WELDER WHO HAS WELDED A
JOINT OR MEMBER CAN BE IDENTIFIED. STAMPS, IF USED, SHALL BE THE LOW-STRESS TYP,
QUALITY ASSURANCE
P
AISC 360 TABLE N5.4-2- INSPECTION TASKS DURING WELDING
VERIFICATION AND INSPECTION QUALITY CONTROL
1. USE OF QUALIFIED WELDERS
2. CONTROL AND HANDLING OF WELDING CONSUMABLES
• PACKAGING
• EXPOSURE CONTROL
3. NO WELDING OVER CRACKED TACK WELDS
4. ENVIRONMENTAL CONDITIONS
• WIND SPEED WITHIN LIMITS
• PRECIPITATION AND TEMPERATURE
5. WPS FOLLOWED
• SETTINGS ON WELDING EQUIPMENT
• TRAVEL SPEED
• SELECTED WELDING MATERIALS
• SHIELDING GAS TYPE/FLOW RATE
• PREHEAT APPLIED
• INTERPASS TEMPERATURE MAINTAINED (MIN/MAX)
• PROPER POSITION (F, V, H OH)
6. WELDING TECHNIQUES
• INTERPASS AND FINAL CLEANING
• EACH PASS WITHIN PROFILE LIMITATIONS
• EACH PASS MEETS QUALITY REQUIREMENTS
QUALITY ASSURANCE
AISC 360 TABLE N5.4-3- INSPECTION TASKS AFTER WELDING
VERIFICATION AND INSPECTION QUALITY CONTROL
1. WELDS CLEANED
2. SIZE, LENGTH AND LOCATION OF WELDS
4. ARC STRIKES
3. WELDS MEET VISUAL ACCEPTANCE CRITERIA
• CRACK PROHIBITION
• WELD/BASE-METAL FUSION
• CRATER CROSS SECTION
• WELD PROFILES
• WELD SIZE
• UNDERCUT
• POROSITY
5. k-AREA¹
6. BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED)
QUALITY ASSURANCE
7. REPAIR ACTIVITES
8. DOCUMENT ACCEPTANCE OR REJECTION OF WELD JOINT OR MEMBER
¹WHEN WELDING OF DOUBLER PLATES, CONTINUITY PLATES OR STIFFENERS HAS BEEN PERFORMED IN THE k-AREA, VISUALLY INSPECT THE WEB k-AREA FOR CRACKS WITHIN 3 IN. (75mm) OF THE WELD.
AISC 360 TABLE N5.6-1- INSPECTION TASKS PRIOR TO BOLTING
VERIFICATION AND INSPECTION QUALITY CONTROL
1. MANUFACTURERS CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALS
2. FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS
4. PROPER BOLTING PROCEDURE SELECTED FOR JOINT DETAIL
3. PROPER FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE, BOLT LENGTH IF
THREADS ARE TO BE EXCLUDED FROM SHEAR PLANE)
5. CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE CONDITION AND
HOLE PREPARATION, IF SPECIFIED, MEET APPLICABLE REQUIREMENTS
6. PRE-INSTALLATION VERIFICATION TESTING BY INSTALLATION PERSONNEL OBSERVED AND
DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS USED
QUALITY ASSURANCE
7. PROPER STORAGE PROVIDED FOR BOLTS , NUTS, WASHERS AND OTHER FASTENER COMPONENTS.
AISC 360 TABLE N5.6-2- INSPECTION TASKS DURING BOLTING
VERIFICATION AND INSPECTION QUALITY CONTROL
1. FASTENER ASSEMBLIES, OF SUITABLE CONDITION, PLACED IN ALL HOLES AND WASHERS
(IF REQUIRED) ARE POSITIONED AS REQUIRED
2. JOINT BROUGHT TO THE SNUG-TIGHT CONDITION PRIOR TO THE PRE-TENSIONING OPERATION.
4. FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC SPECIFICATION,
PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID POINT TOWARD THE FREE EDGES
QUALITY ASSURANCE
AISC 360 TABLE N5.6-3- INSPECTION TASKS AFTER BOLTING
VERIFICATION AND INSPECTION QUALITY CONTROL
1. DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS
QUALITY ASSURANCE
TABLE N6.1- INSPECTION OF STEEL ELEMENTS OF COMPOSITE CONSTRUCTION PRIOR TO CONCRETE PLACEMENT
VERIFICATION AND INSPECTION QUALITY CONTROL
1. PLACEMENT AND INSTALLATION OF STEEL DECK
QUALITY ASSURANCE
2. PLACEMENT AND INSTALLATION OF STEEL HEADED STUD ANCHORS
3. DOCUMENT ACCEPTANCE OR REJECTION OF STEEL ELEMENTS
P
P
P
P
P
P
P
P
P
P
P
P
P
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
P
3. FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM ROTATING O
O
O
O
O
O
O
O
O
O
O
O
O
P
P
P
P
P
P
P
P
P
P
P
P
O
O
O
O
O
O
O
O
O
O
PRIOR TO CONSTRUCTION, VERIFICATION OF COMPLIANCE OF SUBMITTALS.
LEVEL 1
NR
MINIMUM VERIFICATION
PRIOR TO CONSTRUCTION, VERIFICATION OF f ' m AND f ' AAC, EXCEPT WHERE SPECIFICALLY EXEMPTED BY THE CODE.
MASONRY VERIFICATION REQUIREMENTS MINIMUM (TMS 602 TABLE 3)
REQUIRED FOR
QUALITY ASSURANCE(a)
REFERENCE
FOR CRITERIA
LEVEL 2 LEVEL 3 TMS 602
ART. 1.4 B
NR
DURING CONSTRUCTION, VERIFICATION OF SLUMP FLOW AND VISUAL STABILITY
INDEX (VSI) WHEN SELF-CONSOLIDATING GROUT IS DELIVERED
TO THE PROJECT SITE.
ART. 1.5 & 1.6.3
ART. 1.4 B
ART. 1.4 B
NR
NR
DURING CONSTRUCTION, VERIFICATION OF f ' m AND f ' AAC, FOR EVERY 5,000 sq.ft. (465 sq.m).
DURING CONSTRUCTION, VERIFICATION OF PROPORTIONS OF MATERIALS AS
DELIVERED TO THE PROJECT SITE FOR PREMIXED OR PREBLENDED MORTAR,
PRESTRESSING GROUT, AND GROUT OTHER THAN SELF-CONSOLIDATING GROUT.
(a) R=REQUIRED, NR=NOT REQUIRED
R R R ART. 1.5
R
R
R
R
R
R
NR
NR
O
P PERFORM
O OBSERVE
SPECIAL INSPECTIONS AND TESTS
SUGGESTED CONSTRUCTION SEQUENCE :
1. GROUT JAMB AS SHOWN.
2. SAWCUT HALF WIDTH OF CMU WALL.
EXIST CMU TO
BE REMOVED
EXIST CMU
TO REMAIN
(2) L6 X 3-1/2 X 5/16
UP TO 4' - 0" OPENING
BREAK OUT FACE SHELL
AS REQUIRED AND
GROUT SOLID FULL
HEIGHT TO TOP OF
ANGLE
8"
SEE SCHEDULE
SE
E
SC
H
ED
U
LE
EXISTING HEADER TO REMAIN,
VERIFY ELEVATION IN FIELD
EXISTING WOOD TRUSSES TO
REMAIN
EXISTING 2X6 WOOD JAMBS
TO REMAIN. VERIFY STUD
SIZE IN FIELD
NEW 2X6 JAMB EA SIDE OF
DOOR ROUGH OPENING w/
SIMPSON A34 CLIP T&B
EXISTING SINGLE OR
DOUBLE BOTTOM SILL
PLATE, VERIFY IN FIELD
NEW 1/2" DIA SIMPSON TITEN HD
ANCHOR CENTERED IN SILL PLATE
MIN 4-1/2" EMBEDMENT INTO CMU
8" MIN
1'-0" MAX
NEW 1/2" DIA SIMPSON TITEN HD
ANCHOR CENTERED IN SILL PLATE
MIN 4-1/2" EMBEDMENT INTO CMU
SAW CUT MASONRY @ NEW
DOOR OPENING. ALIGN WITH
EXISTING CELLS. VERIFY JAMBS
ARE GROUTED SOLID IN FIELD.
GROUT CMU CELLS AS REQUIRED
EX MASONRY TO
BE REMOVED
8" MIN
1'-0" MAX
VERIFY EXISTING SILL TO CMU
ANCHORAGE, CONTACT EOR IF
EXISTING ANCHORAGE CONFLICTS
w/ NEW SIMPSON ANCHORS
EXISTING SOLID GROUTED
MASONRY TOP CELL. VERIFY IN
FIELD; CONTACT EOR IF CELL IS
HOLLOW
EXISTING SPLIT FACE CMU
TO REMAIN
EX WINDOW TO
BE REMOVED
SF0-01-02
FIN FLOOR
#4 DOWEL @ 8" OC TYP
ADHESIVE DOWEL W/ HILTI
HY-200 INTO EXISTING
FOUNDATION WALL MIN 6"
NEW 5" MIN EXTERIOR
SLAB ON GRADE w/ #4
BAR @ 8" OC, EW
EXISTING FOUNDATION
WALL, VERIFY TOP OF WALL
ELEVATION IN FIELD
EXISTING INTERIOR
SLAB ON GRADE
8" (v
NEW ISOLATION
JOINT WITH SEALANT
EXITING CMU WALL
BEYOND
R
IS
ER
PREFABRICATED TRENCH DRAIN,
SEE ARCHITECTURAL PLAN
1" TREAD#3 NOSING BAR,
TYP
#4 DOWEL @ 8" OC
1'-0" 1'-0"
EXISTING STORM DRAIN
SLOPE
" M
IN
4" VOID FORM8" GRADE WALL,
3 SIDES
(2) #5 BAR, T&B
6" M
IN
#4 @ 8" OC EW
2"
SLOPE
#4 @ 8" OC, EW
(2) CONT #5 BAR,
TYP @ CURB
#4 @ 12" OC, TYP
@ CURB
8" TYP
10" +/- VERIFY FINAL
HEIGHT IN FIELD
CHAMFER EXPOSED
CORNERS
4" VOID FORM42
" M
IN
M
IN5"
8"
8" GRADE WALL,
3 SIDES
(2) #5 BAR, T&B
#4 DOWEL @ 8" OC
2"
SCALE: 3/4" = 1'-0"
1 ELEVATION AT NEW EXTERIOR DOOR
SCALE: 3/4" = 1'-0"
TYPICAL LINTEL OPENING IN EXIST
NON LOAD BEARING CMU WALL
SCALE: 3/4" = 1'-0"
3 SECTION @ NEW DOOR SLAB ON GRADE
DRAWN BY
SHEET TITLE
PROJECT MANAGER
QUALCHECK
DESIGNED BY
PROJECT #
SHEET NUMBER
1"=1000'-0" 0 1000' 2000'
1"=500'-0" 0 500' 1000'
1"=400'-0" 0 400' 800'
1"=200'-0" 0 200' 400'
1"=100'-0" 0 100' 200'
1"=80'-0" 0 80' 160'
1"=60'-0" 0 60' 120'
1"=50'-0" 0 50' 100'
1"=40'-0" 0 40' 80'
1"=30'-0" 0 30' 60'
1"=20'-0" 0 20' 40'
1"=10'-0" 0 10' 20'
16"=1'-0"
0 16' 32'
32"=1'-0" 0 16' 32'
8"=1'-0"
0 8' 16'
16"=1'-0" 0 8' 16'
4"=1'-0"
0 4' 8'
8"=1'-0" 0 4' 8'
2"=1'-0"
0 2' 4'
4"=1'-0" 0 2' 4'
1"=1'-0" 0 1' 2'0 1' 2'
"=1'-0"1 21 1
32"=1'-0" 0 32' 64'
G H
AF
AR
I A
SS
O C
IA
TE
S
REGISTRATION SEAL
CONSULTANT INFORMATION
westmichiganacademy.org www.ghafari.com
GRAND RAPIDS, MI 49503-2900 USA
TEL +1.616.771.0909
37 OTTAWA AVENUE NW
SUITE 700
A. NELSON
4/ 7/
:5
6:
P M
2500303
M. KIEMEL
M. KIEMEL
SF0-01-02
J. MITCHELL
Pre-K and Art Room Improvements
17350 Hazel Street Spring Lake, MI 49456
SPECIAL INSPECTIONS
AND STRUCTURAL
DETAILS
73-1-03
NOT FOR
CONSTRUCTIO
N
REV DATE DOC REL ## - DESCRIPTION
03/24/26 DOC REL 01 - IFB
03/24/26 DOC REL 02 - IFP
A 04/08/26 DOC REL 03 - ADDENDUM A
SCALE:SF0-01-02 3/4" = 1'-0"
4 SECTION @ ENTRY CURB
A
UP
DN
FLOOR PLAN LEGEND
AREA OF WORK
AREA NOT IN CONTRACT
1 HOUR RATED
2 HOUR RATED
EXISTING CONSTRUCTION
TO BE REMOVED
EXISTING CONSTRUCTION
TO REMAIN
DEMOLITION PLAN GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
WHERE PORTIONS OF WALLS AND CEILINGS ARE REMOVED,
RESTORE THE REMAINING PORTIONS TO MATCH THE ORIGINAL
CONSTRUCTION INCLUDING SMOKE AND FIRE RATINGS.
WHERE WALLS, PARTITIONS AND CEILINGS ARE REMOVED, EXTEND
EXISTING FLOOR, WALL AND CEILING FINISHES. PATCH AND REPAIR
ALL SUBSTRATES TO PROVIDE AN EVEN SURFACE FOR A UNIFORM
FINISHED APPEARANCE. IF EXISTING FINISHES CAN NOT BE
EXTENDED, TO THE SATISFACTION OF THE OWNER AND ARCHITECT,
REMOVE AND REPLACE FINISHES WITH NEW MATERIALS.
FLOOR OPENINGS: PATCH TO MATCH ADJACENT SURFACES AND
FIRE SEPARATION RATINGS OF EXISTING FLOOR ASSEMBLY.
MASONRY WALLS: RESTORE REMAINING MASONRY WALLS TO
ORIGINAL CONDITION. MASONRY WALLS SHALL BE REBUILT USING
NEW CMU TO MATCH THE EXISTING MATERIALS, SIZES, THICKNESS,
INCLUDING BONDING, COURSING AND COLOR. TOOTH NEW
MASONRY INTO EXISTING UNLESS NOTED OTHERWISE. SUBMIT
SAMPLES TO ARCHITECT/ENGINEER AND OWNER FOR APPROVAL.
CEILINGS: REMOVE AS INDICATED INCLUDING FRAMING AND
SUPPORT MEMBERS, HANGERS, AND OTHER RELATED ITEMS.
COORDINATE WITH OTHER TRADES TO CONFIRM SCOPE AND
EXTENTS OF DEMOLITION FOR BUILDING UTILITIES. REFER TO
MECHANICAL, ELECTRICAL AND SPECIAL SYSTEM DRAWINGS FOR
ADDITIONAL INFORMATION.
FURNISHINGS, FIXTURES AND EQUIPMENT: REMOVE OR RELOCATE
ITEMS LEFT BY OWNER. INCLUDE REMOVAL OF FREE-STANDING
AND WALL MOUNTED ITEMS. COORDINATE WITH OWNER FOR ITEMS
TO BE SAVED AND RETURNED TO OWNER.
SIGNAGE: REMOVE WALL MOUNTED SIGNAGE, PLAQUES, DISPLAY
CASES, ETC. SALVAGE FOR REUSE AS REQUIRED OR INDICATED.
FLOORING: WHERE MULTIPLE LAYERS OF FLOORS EXIST REMOVE
ALL LAYERS TO EXPOSE CONCRETE SLAB OR UNDERLYING
SUBSTRATE, UNLESS OTHERWISE NOTED. VERIFY IN FIELD.
FIRE RATED ASSEMBLIES: REPAIR ALL REMAINING FIRE-RATED
ASSEMBLIES DAMAGED DURING DEMOLITION TO ORIGINAL FIRE
PROTECTION REQUIREMENTS. CONTACT THE ARCHITECT TO VERIFY
U.L. ASSEMBLIES TO BE USED FOR REPAIRS.
DEMOLITION ROOF PLAN GENERAL NOTES
1.
2.
3.
REMOVE ANY ITEMS NOT SPECIFICALLY IDENTIFIED TO BE REMOVED
WHICH MUST OBVIOUSLY BE DEMOLISHED FOR ROOF WORK TO
TAKE PLACE. VERIFY WITH ARCHITECT IF NECESSARY.
CONTRACTOR SHALL FURNISH NECESSARY TEMPORARY
PROTECTION OF BUILDING INTERIOR FROM ELEMENTS OF WEATHER
AT ALL TIMES.
EXTEND ALL PLUMBING VENTS AND MECHANICAL EQUIPMENT CURBS
TO A MINIMUM 12" HEIGHT ABOVE FINISH ROOFING. ALL FITTINGS TO
BE WATER TIGHT.
FLOOR PLAN GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
INTERIOR PARTITIONS ARE DIMENSIONED TO THE FACE OF
PARTITIONS. CONTRACTOR SHALL COORDINATE FINAL DIMENSIONS
WITH THE FINISH SCHEDULE WHEN CRITICAL TO THE INSTALLATION
OF MILLWORK, CASEWORK, FIXTURES, OR EQUIPMENT.
ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD BEFORE
PROCEEDING WITH THE WORK. THE ARCHITECT SHALL BE NOTIFIED
OF ANY DISCREPANCIES. CONTRACTOR IS RESPONSIBLE FOR
DIMENSIONS FOR OUT-OF-SEQUENCE WORK.
DOOR OPENINGS THAT ARE NOT DIMENSIONALLY LOCATED ARE TO
BE CENTERED BETWEEN WALLS OR POSITIONED WITH ONE JAMB 4"
FROM AN ADJACENT WALL OR COLUMN AS SHOWN ON THE PLANS
AND/OR DETERMINED FROM THE DETAILS.
CRITICAL "HOLD" OR "CLEAR" DIMENSIONS ARE TO FACE OF WALL
FINISHES AND ARE IDENTIFIED ON DOCUMENTS.
DIMENSIONS FOR MASONRY CONSTRUCTION ARE NOMINAL AND DO
NOT INCLUDE SURFACE FINISHES.
RECEIVE CERTIFIED OR APPROVED EQUIPMENT DRAWINGS PRIOR
TO PROCEEDING WITH AFFECTED WORK.
VERIFY LOCATIONS AND SIZES OF OPENINGS, CURBS, BASES AND
ANCHOR BOLTS WITH OTHER TRADES.
WHERE ENLARGED PLANS ARE REFERENCED, REFER TO ENLARGED
PLAN FOR WALL TYPES, DIMENSIONS, AND SUPPLEMENTARY
INFORMATION.
REFER TO WALL TYPES FOR NON-LOAD BEARING INTERIOR
PARTITIONS. WALL THICKNESSES LISTED ARE ACTUAL AND DO NOT
INCLUDE SURFACE FINISHES.
REFER TO ROOM FINISH SCHEDULE AND/OR PLANS FOR INTERIOR
FINISHES.
REFER TO LIFE SAFETY DRAWINGS FOR SPECIFIC INFORMATION
RELATED TO OCCUPANT COUNTS, EXITING AND WALL RATINGS.
REFER TO THE APPROVED SUBMITTAL DRAWINGS FOR FIXTURES,
EQUIPMENT, FURNITURE AND FURNISHING DIMENSIONS AND OTHER
DETAILED INFORMATION.
ALL MILLWORK EDGING FOR DOORS AND DRAWER FRONTS TO BE
3MM PVC EDGEBANDING MATCHING LAMINATE.
ROOF PLAN GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
ROOFING INSTALLATION SHALL ACCOMMODATE ALL EQUIPMENT AND
OTHER ITEMS WHICH WILL BE INSTALLED ON THE ROOF, REFER TO
MECHANICAL, ELECTRICAL, PLUMBING AND OTHER DRAWINGS FOR
ADDITIONAL INFORMATION. PROVIDE FLASHINGS AND ACCESSORIES
AS REQUIRED FOR COMPLETE INSTALLATION.
PROVIDE FLASHINGS AT ALL ROOF PENETRATIONS AND SEAL FOR
WEATHERTIGHT CONDITION; VERIFY QUANTITIES, SIZES AND
LOCATIONS WITH ALL TRADES.
REFER TO ROOFING SPECIFICATIONS FOR REQUIREMENTS WHEN
NEW EQUIPMENT OR OPENINGS ARE REQUIRED IN AN EXISTING
ROOF AREA.
PROVIDE WOOD NAILERS/BLOCKING/BRACING TO SUPPORT
EQUIPMENT AND EDGES OF SHEATHING.
CURBS AND ACCESSORIES FOR THE FOLLOWING ITEMS SHALL BE
FURNISHED BY OTHER TRADES FOR INSTALLATION BY
ARCHITECTURAL TRADES, COORDINATE QUANTITIES, SIZES AND
LOCATIONS WITH THE APPROPRIATE TRADES.
ROOF MOUNTED RELIEF VENTS AND ACCESSORIES
PENETRATIONS FOR PIPING, POWER FEEDS, ETC.
CONTRACTOR RESPONSIBLE FOR ROOF TRAFFIC PROTECTION
DURING CONSTRUCTION. AREAS OF WORK AND TRAFFIC BY
VARIOUS TRADES SHALL BE PROTECTED FROM DAMAGE AND WEAR.
ALL ROOF DETAIL DRAWINGS CONTAINED IN THIS SET ARE
DIAGRAMMATIC. ADJUST ROOF DETAILS BASED ON SPECIFIC
ROOFING SYSTEM SELECTED ACCORDING TO MANUFACTURER'S
WRITTEN SPECIFICATIONS AND APPROVED DETAIL DRAWINGS. ALL
ASSEMBLY COMPLICATIONS SHOULD BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT.
L FIRST FLOOR
98' - 0"
SCRIBE
2'-0"
BF BASE
3'-0"
CHILD
3'-0"
8' -1
0"
- 2
2' -1
0" 2'
-0
4' -0
8'-1"
2' -0
HARD-WIRED
AUTOMATIC
FAUCETS
DUTCH
DOOR
SCRIBE2'-0"3'-0"3'-0"
SD
SD
E
XI
ST
IN
G M
AT
C
H
REINSTALL
PROJECTOR
REPAINT
CMU WALL
SSM COUNTERS, BACK AND SIDE SPLASHES
PLAM CABINETS
PLAM
CABINETS
FE
FE FE FE
REINSTALL
WHITE BOARD
WALL BASE
AS SCHED
EO
'-0
/8
'-3
/8
'-1
5/
8"
PRE-K
CLSM 2
PRE-K
CLSM 1
TLT
TLT
BF
UNISEX
TLT
27'-8"
SERVER
JANITOR
C O
R R
ID
O
R
PROVIDE NEW EXHAUST
FAN TO SERVE 3 TOILET
ROOMS; INSTALL IN ATTIC
ABOVE BF UNISEX TOILET
ROOM WITH MAINTENANCE
CATWALK; VENT THRU
SHINGLED ROOF
SENSORY
ROOM
8" 2'
-4
AE1-01-01
- 6
'-4
2R 2'-0" 5'-6"
SLOPE
(E)DS TO
UG STORM
(E)DS TO
UG STORM
1'-0"
FIRST FLOOR
100' - 0"
NEW PHENOLIC
RESIN COUNTER,
BACK AND SIDE
SPLASHES
NEW FAUCETS &
S.STL SINKS AND
PLASTER TRAPS
EXISTING SHELVES
ABOVE REMAIN
10'-7" VIF
EXISTING WD VENEER
CASEWORK REMAINSSINK
BF
SINK
DEEP
REPAINT WALL
SURROUNDING SINK
L FIRST FLOOR
98' - 0"
4' -0
2'
-2
2' -1
0"
9' -0
UTILITY
3'-0"
BF SINK
3'-0" SCRIBE
6'-1"
3'-0" 3'-0" SCRIBE
6'-1"
REPAINT
CMU WALL
EOSD
PLAM CABINETS
NEW PHENOLIC RESIN
COUNTER, BACK AND
SIDE SPLASHES
BASE AS SCHED
PLAM CABINETS FE
FE
AE1-01-01
ART-1
ART
STORAGE
REPAINT WALL TO
MATCH EXISTING
ART 2
AE1-01-01
PRE-K
CLSM 2
PRE-K
CLSM 1
TLT
CORRIDOR
SENSORY
ROOM
JANITOR
SERVER
2 3
OFFICE
EXISTING LVT
TO REMAIN
A
AE1-01-01
+/- 12'-5 3/8" 1'-6" 6'-0"
'-0
/8
7'-1"
BF CHILD
WC-3
19'-11 3/8"
TLT
TLT
BF
UNISEX
TLT
27'-8"
CHILD
WC-2
(E)WC
(E)LAV
2'-0"
7'-0"
BF WC-1
5' -6
FD
FD
BF LAV
AE1-01-01
2 SIM
2' -6
1'
-5
GRAB
BARS
MIR
GRAB BARSBF LAV
MIR
18" GRAB
BAR
GRAB BARS
SD
SD
SDSD
FULL HT CT
FINISH
FULL HT
CT FINISH
8'-8"
1' -4
1'
-4
3' -8
2'
-9
- 3
'-7
/8
FD3-0
SSM COUNTERTOP AND
SPLASHES; EASED EDGE
CABINET
HARDWARE; TYP
3/4" PARTICLE BOARD WITH
PLASTIC LAMINATE ON FACE
W/ EDGEBANDING TYP
3/4" PARTICLE BOARD
WITH BLACK MELAMINE
FINISH ON EXPOSED
INTERIOR SURFACES
BASE AS SCHED
FINISH FLOOR
4"
2'-1"
3"
R
EF
ER
T
O E
LE
VA
TI
O
N S
1/
4"
SEALANT
2X WOOD
BLOCK
BARRIER FREE
COMPLIANT SINK
FACE OF WALL PROVIDE
WOOD BLOCKING AS
REQUIRED TO SUPPORT
THE CABINETRY. TYP
3/4" PARTICLE BOARD WHITE
MELAMINE FINISH ON EXPOSED
INTERIOR SURFACES AND
ADJUSTABLE SHELVES
MELAMINE SHELF (TYP FOR 2)
3/4" PARTICLE BOARD WITH
PLASTIC LAMINATE ON FACE
W/ EDGEBANDING TYP
1'-3"
NOTE: WHERE PLASTER TRAP OCCURS, COORDINATE PLUMBING TO ENSURE
BOTTLE CLEARANCES AND SERVICEABILITY COMPLY WITH MANUF REQ'S
A
A
CABINET
1/ 2"
1"
SOFFIT / CEILING,
REFER TO TYPICAL
DETAILS
CEILING PLAN GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
LIGHT FIXTURES SHALL BE LOCATED IN THE CENTER OF THE ROOM
OR SPACE, UNLESS NOTED OTHERWISE.
LIGHT FIXTURES IN ACOUSTICAL CEILING PANELS SHALL BE
CENTERED IN THE PANEL, UNLESS NOTED OTHERWISE.
SUPPLY, RETURN OR EXHAUST REGISTERS LOCATED IN THE CORNER
OF A ROOM OR SOFFIT SHALL BE LOCATED 6" FROM THE WALL OR
SOFFIT, UNLESS NOTED OTHERWISE.
IN THE EVENT OF CONFLICTS BETWEEN THE REFLECTED CEILING
PLANS AND THE CORRESPONDING DRAWINGS OF OTHER
DISCIPLINES, THE CONTRACTOR SHALL BRING THE CONFLICT TO THE
ATTENTION OF THE ARCHITECT FOR CLARIFICATION PRIOR TO
INSTALLATION.
EXIT SIGNS SHALL BE CENTERED IN CORRIDORS AND LOCATED A
DISTANCE OF 1'-0" FROM WALLS (TO CENTER LINE OF FIXTURE)
UNLESS NOTED OTHERWISE. VERIFY EXIT SIGNS LOCATIONS WITH
THE AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION.
REFER TO THE ROOM FINISH SCHEDULE FOR CEILING FINISHES AND
COLORS WHICH ARE NOT INCLUDED ON THE CEILING PLANS.
CEILING HEIGHT (FINISH FLOOR TO FINISH CEILING): REFER TO
CEILING PLANS.
REFER TO DETAILS FOR TYPICAL CEILING DETAILS.
CEILING PLAN LEGEND
2X4 ACOUSTICAL PANEL CEILING
2X2 ACOUSTICAL PANEL CEILING
2X4 LIGHT FIXTURE.
REFER TO ELECTRICAL.
2X2 LIGHT FIXTURE.
REFER TO ELECTRICAL.
EMERGENCY 2X4 LIGHT FIXTURE.
REFER TO ELECTRICAL.
EMERGENCY 2X2 LIGHT FIXTURE.
REFER TO ELECTRICAL.
2X2 SUPPLY.
REFER TO MECHANICAL.
2X2 RETURN.
REFER TO MECHANICAL.
REFER TO MECHANICAL AND
ELECTRICAL FOR ADDITIONAL SYMBOLS
2X2 EXHAUST.
REFER TO MECHANICAL.
7' - 10" 7' - 10" 7' - 10"
TEXTURED
GYP BD
CEILING
TEXTURED
GYP BD
CEILING
SUPPLY AND DRAIN
PIPING INSULATION
BARRIER FREE
COMPLIANT
UNDERMOUNT SINK
2'-
6" 2'- 4"
9"
SEALANT
BARRIER-FREE
CLEARANCE LIMIT
SSM COUNTERTOP
AND SPLASHES
REMOVABLE PLASTIC
LAMINATE SHROUD
AND ATTACHMENT
BRACKETS T&B
FACE OF WALL PROVIDE
WOOD BLOCKING AS
REQUIRED TO SUPPORT
THE CABINETRY. TYP
3/4" PARTICLE BOARD WHITE
MELAMINE FINISH ON EXPOSED
INTERIOR SURFACES AND
ADJUSTABLE SHELVES
MELAMINE SHELF (TYP FOR 2)
3/4" PARTICLE BOARD WITH
PLASTIC LAMINATE ON FACE
W/ EDGEBANDING TYP
1'-3"
R
EF
ER
T
O E
LE
VA
TI
O
N S
1/
4"
2'-1"
A
3/4" PARTICLE BD WITH
MELAMINE FINISH ON EXP'D
INTERIOR SURFACES
BASE AS SCHED
FINISHED FLOOR
CABINET HARDWARE
(HDW-1); TYP
DRAWER STOP; PLAM CLAD
1/4" DRAWER DIVIDERS
4"
R
EF
ER
T
O E
LE
VA
TI
O
N S
1' -2
EQ
EQ
2X WOOD BLOCK BASE
SSM COUNTERTOP
SEALANT
BACKSPLASH 2'-1"
SEALANT
FACE OF WALL PROVIDE
WOOD BLOCKING AS
REQUIRED TO SUPPORT
THE CABINETRY. TYP
3/4" PARTICLE BOARD WHITE
MELAMINE FINISH ON EXPOSED
INTERIOR SURFACES AND
ADJUSTABLE SHELVES
MELAMINE SHELF (TYP FOR 2)
3/4" PARTICLE BOARD WITH
PLASTIC LAMINATE ON FACE
W/ EDGEBANDING TYP
1'-3"
3/4" PARTICLE BOARD WITH
PLASTIC LAMINATE ON FACE
W/ EDGEBANDING TYP
A
A
ACCESSORIES LEGEND
MARK DESCRIPTION
GB-01
GRAB BAR
18" LONG, VERTICAL ORIENTATION
GRAB BAR (BACK WALL)
36" LONG, HORIZONTAL ORIENTATION
GRAB BAR (SIDE WALL)
42" LONG, HORIZONTAL ORIENTATION
OWNER
FURNISHED
CONTRACTOR
FURNISHED
X
SD-01 SOAP DISPENSER X
PTD-01 PAPER TOWEL DISPENSER X
WR-01 WASTE RECEPTACLE X
SND-01 SANITARY NAPKIN DISPENSER X
TPD-01 TOILET PAPER DISPENSER X
MIR-01 MIRROR X
TLP-01 TOILET PARTITION X
CONTRACTOR
INSTALLED
X
X
X
GB-02 GRAB BAR (SIDE WALLS)
18" LONG, VERTICAL ORIENTATION
X X
MANUFACTURER MODEL
BOBRICK B-6806
SERIES
X X
BOBRICK B-2908-2436
HADRIAN INC FLOOR MTD,
OVERHEAD
BRACED
BOBRICK B-6806
SERIES
1'-0"
EXTEND HANDRAIL
BEYOND NOSINGS
AS INDICATED
1-1/2" O.D. GALV STEEL PIPE
HANDRAIL EA SIDE; EPOXY PAINT
TO MATCH SIDING GREY COLOR;
ARCHITECTURAL SMOOTH WELDS
1'-0"
3' -0
1' -3
1'
-9
CORE AND EPOXY
EMBED HANDRAIL
POST IN CURB1'
-9
SLOPE
DRAWN BY
SHEET TITLE
PROJECT MANAGER
QUALCHECK
DESIGNED BY
PROJECT #
SHEET NUMBER
1"=1000'-0" 0 1000' 2000'
1"=500'-0" 0 500' 1000'
1"=400'-0" 0 400' 800'
1"=200'-0" 0 200' 400'
1"=100'-0" 0 100' 200'
1"=80'-0" 0 80' 160'
1"=60'-0" 0 60' 120'
1"=50'-0" 0 50' 100'
1"=40'-0" 0 40' 80'
1"=30'-0" 0 30' 60'
1"=20'-0" 0 20' 40'
1"=10'-0" 0 10' 20'
16"=1'-0"
0 16' 32'
32"=1'-0" 0 16' 32'
8"=1'-0"
0 8' 16'
16"=1'-0" 0 8' 16'
4"=1'-0"
0 4' 8'
8"=1'-0" 0 4' 8'
2"=1'-0"
0 2' 4'
4"=1'-0" 0 2' 4'
1"=1'-0" 0 1' 2'0 1' 2'
"=1'-0"1 21 1
32"=1'-0" 0 32' 64'
G H
AF
AR
I A
SS
O C
IA
TE
S
REGISTRATION SEAL
CONSULTANT INFORMATION
westmichiganacademy.org www.ghafari.com
GRAND RAPIDS, MI 49503-2900 USA
TEL +1.616.771.0909
37 OTTAWA AVENUE NW
SUITE 700
A. NELSON
4/ 7/
:5
6:
P M
2500303
A. NELSON
A. NELSON
AE1-01-01
A. ECKERT
Pre-K and Art Room Improvements
17350 Hazel Street Spring Lake, MI 49456
ARCHITECTURAL FLOOR
AND CEILING PLANS,
INTERIOR ELEVATIONS
73-1-03
NOT FOR
CONSTRUCTIO
N
SCALE:
NORTH
1/8" = 1'-0"
FLOOR PLAN PRE-K
SCALE:AE1-01-01 1/4" = 1'-0"
2 INTERIOR ELEVATION
SCALE:
NORTH
1/8" = 1'-0"
FIRST FLOOR PLAN ART
SCALE:AE1-01-01 1/4" = 1'-0"
3 INTERIOR ELEVATION
SCALE:
NORTH
1/8" = 1'-0"
FIRST FLOOR PLAN ART 2
SCALE:AE1-01-01 1/4" = 1'-0"
4 INTERIOR ELEVATION
SCALE:
NORTH
1/8" = 1'-0"
DEMOLITION PLAN PRE-K
KEY NOTES - DEMOLITION
NOTE
NUMBER NOTE TEXT
1 REMOVE WINDOW, WINDOW TREATMENTS, AND PORTION OF
WALL FOR NEW DOOR.
2 REMOVE PORTION OF CMU WALL FOR NEW DOOR AND FRAME.
SHORE WALL AND STRUCTURE.
3 REMOVE AND SALVAGE WHITE BOARD AND SHORT-THROW
WALL MOUNTED PROJECTOR FOR RELOCATION.
4 REMOVE DOOR AND HARDWARE; FRAME TO REMAIN.
5 REMOVE CARPET FLOORING AND WALL BASE.
6 REMOVE ACP CEILING SYSTEM, LIGHTING, HVAC DIFFUSERS,
ETC.
7 REMOVE SHELVING SYSTEM.
8 SALVAGE CLOCK; PROTECT AND STORE FOR REUSE.
9 SALVAGE TACKSTRIP
10 REMOVE ELECTRICAL AND TELECOM / DATA DEVICES AND
COVER PLATES FOR REPLACEMENT WITH TAMPER-RESISTANT
TYPE.
11 REMOVE VCT FLOOR TILE AND RESILIENT WALL BASE.
12 REMOVE STORAGE SHELVING.
13 REMOVE AND RESET TOILET FOLLOWING NEW FLOORING AND
PAINTING WORK.
14 SAWCUT AND REMOVE PORTIONS OF SLAB ON GRADE;
COORDIANTE WITH PLUMBING AND OTHER TRADES FOR
EXTENT AND LOCATIONS REQUIRED.
15 CONFIRM 5-FT MINIMUM EGRESS ROUTE CLEARANCE OUTSIDE
NEW EXTERIOR DOOR; RELOCATE SMALL PLAYGROUND
ELEMENT IF REQUIRED AND CERTIFY INSTALLATION.
16 REMOVE EXISTING EXHUAST FAN IN GYPSUM BOARD AT
UNDERSIDE OF TRUSSES FOR REPLACEMENT. EXISTING DUCT
AND ROOF VENT REMAINS FOR REUSE.
KEY NOTE - NEW WORK
NOTE
NUMBER NOTE TEXT
1 SAW CUT CMU TO CENTER NEW MASONRY OPENING BELOW
EXISTING WINDOW OPENING, ALIGNED WITH MASONRY
COURSES; PATCH CMU AND GROUT SOLID AS DIRECTED BY
STRUCTURAL; NEW JAMB FRAMING ABOVE TO UNDERSIDE OF
EXISTING HEADER; PATCH TEXTURED PLASTER WALL SKIM
COAT FINISH TO MATCH EXISTING; PATCH EXTERIOR
SHEATHING/ VAPOR BARRIER/ AND SIDING WITH BREAK METAL
TRIM CLADDING. REPAINT EXTERIOR MASONRY WALL FROM
INSIDE CORNER TO EXTERIOR CORNER.
2 PROVIDE MASONRY LINTEL AND TOOTH-IN NEW CMU;
GROUTED SOLID.
3 REINSTALL WHITE BOARD AND WALL MOUNTED SHORT-THROW
WALL MOUNTED PROJECTOR; INCLUDING NEW POWER AND
DATA.
4 INSTALL SALVAGED WHITE BOARD.
5 NEW WALL MOUNTED SHELVES WITH WALL PHONE.
6 INSTALL SALVAGED CLOCK.
7 INSTALL SALVAGED TACKSTRIP AT TOP OF WHITE BOARD.
8 REMOVE AND REPLACE ART SINK CABINETS, SINKS, AND
FAUCETS. PROVIDE NEW PLASTER TRAPS. COUNTERTOP TO
BE PHENOLIC RESIN BLACK.
9 WHERE SLAB ON GRADE REMOVED: ADD & COMPACT
AGGREGATE FILL AND ASTM E1749 15MIL VAPOR BARRIER,
PATCH CONCRETE SLAB & DOWEL IN TO EXISTING SLAB THAT
REMAINS; PROVIDE EXP JT MATERIAL & SEALANT AT
ADJACENT WALLS.
10 PROVIDE FIRE RATED ACCESS PANEL AT GYPSUM SHEATHING
AT UNDERSIDE OF ROOF TRUSSES, PLYWOOD CATWALK
PLATFORM AT TRUSS BOTTOM CORDS FOR EXHAUST FAN
EQUIPMENT INSTALLATION AND MAINTENANCE ACCESS (SPAN
4 TRUSSES MIN), AND WEATHERPROOF EXHAUST VENT THRU
ROOF.
11 NEW SUPPORTED CONCRETE STOOP ON COMPACTED FILL;
DOWELED TO BUILDING WITH STEPS UP +/-10" RISE WITH
EPOXY PAINTED GALV STL HANDRAILS BOTH SIDES; PROVIDE
NEW TRENCH DRAIN (COMPARABLE TO ZURN Z883-HPS) PIPED
TO UNDERGROUND STORM PIPING; NEW 4"X96"W SIDEWALK
EXTENDED TO EXISTING SIDEWALK; DIRECT DRAINAGE TO
DRAIN/AWAY FROM BUILDING; RESTORE SURROUNDING
GRADE.
12 REMOVE AND REPLACE ART COUNTERTOP, SINKS, FAUCETS,
AND PLASTER TRAPS; MODIFY PIPING AS REQUIRED.
COUNTERTOP TO BE PHENOLIC RESIN BLACK.
13 WALL MOUNTED EXIT SIGN CENTERED ABOVE DOOR.
SCALE:AE1-01-01 1/4" = 1'-0"
1 ENLARGED PLAN
SCALE: 1" = 1'-0"
7 SECTION
SCALE: 3" = 1'-0"
8 TALL CABINET EDGE DETAIL
SCALE:
NORTH
1/8" = 1'-0"
PARTIAL CEILING PLAN
TOILET ROOMS
SCALE: 1" = 1'-0"
6 SECTION BARRIER FREE SINK
SCALE: 1" = 1'-0"
5 SECTION
REV DATE DOC REL ## - DESCRIPTION
03/24/26 DOC REL 01 - IFB
03/24/26 DOC REL 02 - IFP
A 04/08/26 DOC REL 03 - ADDENDUM A
A
A
SCALE: 3/4" = 1'-0"
9 HANDRAIL DETAIL A
| GO0-00-00 - COVER SHEET |
| SF0-01-02 - SPECIAL INSPECTIONS AND STRUCTURAL DETAILS |
| AE1-01-01 - ARCHITECTURAL FLOOR AND CEILING PLANS, INTERIOR ELEVATIONS |
File details come from the government source that posted it. Updated .