25.256 WHA Ulbrich Heights Kitchen Renovations BID Dwgs.pdf
PDF 9 MB Posted
- Solicitation number
- 37430
- Issued by
- New Haven County, Waterbury City, Connecticut
About this file
This document is a set of electrical bid drawings for the Wallingford Housing Authority's Ulbrich Heights Complex Kitchen Renovations project located at Wharton Brook Drive, Louis Circle, and Tremper Drive in Wallingford, Connecticut. The project encompasses kitchen renovations across multiple building types (Types A through E and additional unit types 2-7) within the residential complex. The drawings were issued for bid as of March 6, 2026, and were prepared by Silver Petrucci + Associates, located in Hamden and New London, Connecticut. The scope includes electrical work across garden buildings with multiple apartment unit types and configurations, including standard and mobility-modified units.
The electrical work specifications detail comprehensive renovation requirements including replacement and installation of fixtures, receptacles, switches, and related electrical components across the various apartment types. Construction includes furnishing and installing GFCI tamper-resistant receptacles, 50-ampere 240-volt 4-wire range receptacles, recessed junction boxes for range hoods, and ceiling-mounted light fixtures with LED lamps (specified from HD Supply). Demolition notes indicate selective removal of existing electrical devices with reuse of back boxes and wiring where applicable. All work must comply with Connecticut State Building Code and Fire Safety Code, with materials conforming to UL and NEMA standards. The specifications mandate new combination arc-fault breakers compatible with existing GE Q-line series panels, and wiring devices from manufacturers including Leviton, Hubbell, or Bryant, with all work to remain in proper working order for one year following final acceptance.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APARTMENT
TYPE 1
APARTMENT
TYPE 3
APARTMENT
TYPE 2
APARTMENT
TYPE 2 (M)
APARTMENT
TYPE 3 (M)
APARTMENT
TYPE 1 (M)
APARTMENT
TYPE 1
APARTMENT
TYPE 3
APARTMENT
TYPE 2
APARTMENT
TYPE 3-1
APARTMENT
TYPE 2-1
APARTMENT
TYPE 2 (M)
APARTMENT
TYPE 3 (M)
APARTMENT
TYPE 1 (M)
Drawing Title:Revised By:Date:Description:Revision:Project Title: Date:
Scale:
Drawn By:
Project Number:
Drawing Number:
03/06/2026
25-256
- -WALLINGFORD HOUSING AUTHORITY:
ULBRICH HEIGHTS COMPLEX KITCHEN RENOVATIONS
WHARTON BROOK DR., LOUIS CIRCLE, & TREMPER DR.
WALLINGFORD, CT 06492
AS INDICATED
SILVER
203 230 9007
3190 WHITNEY AVENUE HAMDEN
silverpetrucelli.com
CT 06320
ASSOCIATESPETRUCELLI +
CT 06518
311 STATE STREET NEW LONDON
Project Phase:
State Project Number:
ISSUED FOR BID
OVERALL GARDEN BUILDING
TYPES A & B
DJT
I. ELECTRICAL GENERAL REQUIREMENTS
A. ALL WORK SHALL COMPLY WITH CONNECTICUT STATE BUILDING CODE AND CONNECTICUT STATE FIRE
SAFETY CODE AND SHALL BE ACCOMPLISHED IN A NEAT AND WORKMAN LIKE MANNER.
B. MATERIAL & EQUIPMENT SHALL BE NEW UNLESS SPECIFICALLY NOTED OTHERWISE AND SHALL BE LISTED BY
UNDERWRITERS LABORATORIES.
C. SUBMITTALS:
1. SUBMIT PRODUCT DATA, SHOP DRAWINGS, RECORD DRAWINGS AND O&M MANUALS WHERE REQUIRED
BY INDIVIDUAL SPECIFICATION SECTIONS.
2. SUBMIT THREE COPIES TO OWNER.
D. ELECTRICAL INSTALLATION:
1. COORDINATE ELECTRICAL SYSTEMS, EQUIPMENT AND MATERIALS INSTALLATION WITH OTHER
BUILDING COMPONENTS. REFER ALL CONFLICTS TO ENGINEER BEFORE CONTINUING WITH WORK.
2. INSTALL SYSTEMS TO PROVIDE MAXIMUM HEADROOM POSSIBLE UNLESS INDICATED OTHERWISE.
3. INSTALL SYSTEMS LEVEL, PLUMB, PARALLEL AND PERPENDICULAR TO OTHER BUILDING SYSTEMS AND
COMPONENTS.
4. INSTALL EQUIPMENT TO FACILITATE REPAIR, MAINTENANCE OR REPLACEMENT.
5. PERFORM CUTTING AND PATCHING REQUIRED TO REMOVE AND REPLACE DEFECTIVE WORK OR WORK
NOT CONFORMING TO REQUIREMENTS OF CONTRACT DOCUMENTS.
6. CONTRACTOR SHALL LEAVE THE ENTIRE ELECTRICAL SYSTEM IN PROPER WORKING ORDER AND
SHALL, WITHOUT ADDITIONAL CHARGE, REPLACE ANY WORK, MATERIALS, OR EQUIPMENT FURNISHED & INSTALLED BY HIM UNDER THIS WHICH DEVELOP DEFECTS, EXCEPT FROM NORMAL WEAR & TEAR, WITHIN ONE YEAR FROM DATE OF FINAL ACCEPTANCE BY OWNER.
II. RACEWAYS, BOXES, AND FITTINGS
A. COMPONENTS AND INSTALLATION SHALL COMPLY WITH NFPA 70 & NEMA AND SHALL BE UL LISTED.
B. INTERIOR RACEWAYS SHALL BE ELECTRICAL METALLIC TUBING IN UNFINISHED SPACES AND SURFACE
RACEWAY (WIREMOLD OR EQUAL) IN FINISHED SPACES.
C. EXTERIOR RACEWAYS ABOVE GROUND SHALL BE RIGID METAL CONDUIT OR LIQUID-TIGHT FLEXIBLE METAL
CONDUIT (MAX. LENGTH 5').
D. EXTERIOR RACEWAYS BELOW GROUND SHALL BE RIGID METAL CONDUIT OR SCHEDULE 40 PVC.
E. USE RACEWAY FITTINGS COMPATIBLE WITH ASSOCIATED RACEWAY AND APPLICATION.
F. BOXES SHALL BE STEEL CONFORMING TO UL 514A AND NEMA OS1. FITTINGS SHALL CONFORM TO UL 514B.
III. BUILDING WIRE
A. WIRE SHALL COMPLY WITH UL 83 AND NEMA WC-5. CONNECTORS SHALL COMPLY WITH UL 486A.
B. CONDUCTORS SHALL BE COPPER AND INSULATION SHALL BE THHN/THWN.
C. INTERIOR WIRING SHALL BE BUILDING WIRE IN CONDUIT WHERE EXPOSED AND MC CABLE WHERE
CONCEALED.
IV. SUPPORTING DEVICES
A. SUPPORTS, HARDWARE AND FASTENERS SHALL BE PROTECTED WITH ZINC COATING.
B. SLEEVES SHALL BE SCHEDULE 40 GALVANIZED STEEL PIPE.
C. CONFORM TO MANUFACTURER'S RECOMMENDATIONS FOR SELECTION AND INSTALLATION OF SUPPORTS
AND CONFORM TO THE FOLLOWING:
1. SUPPORT INDIVIDUAL HORIZONTAL RACEWAYS BY SEPARATE PIPE HANGERS.
2. SUPPORT RACEWAY WITHIN ONE FOOT OF ANY UNSUPPORTED BOX.
D. INSTALL SLEEVES IN CONCRETE SLABS AND WALLS AND FIRE RATED WALLS AND FLOORS. APPLY UL LISTED
FIRE STOPPING MATERIAL WHERE REQUIRED.
V. ELECTRICAL IDENTIFICATION
A. PROVIDE EQUIPMENT IDENTIFICATION LABELS OF ENGRAVED PLASTIC LAMINATE FOR METER SOCKETS, PANELBOARDS & DISCONNECTS.
B. CONDUCTORS SHALL BE COLOR CODED IN ACCORDANCE WITH NFPA 70 AND ANSI A13.1.
C. PROVIDE TYPED PANELBOARD CIRCUIT DIRECTORY FOR EACH PANELBOARD.
D. PROVIDE UNDERGROUND WARNING TAPE FOR ALL BURIED ELECTRICAL SERVICES.
VI. PANELBOARDS
A. ALL LOAD CENTERS ARE EXISTING GE Q-LINE SERIES. PROVIDE NEW COMBINATION ARC-FAULT BREAKERS
THAT ARE LISTED FOR USE WITH THESE PANELS.
B. UPDATE PANEL DIRECTORIES.
VII.LIGHT FIXTURES
A. MANUFACTURERS:
A. LITHONIA
B. COOPER
C. COLUMBIA
D. OTHERS AS SPECIFIED OD ALLOWED BY EQUAL SUBSTITUTION.
B. PRODUCTS: REFER TO LIGHT FIXTURE SCHEDULE.
C. PROVIDE PRODUCT DATA SUBMITTALS.
VIII. WIRING DEVICES
A. MANUFACTURERS:
1. LIEVITON
2. HUBBELL
3. BRYANT
4. OTHERS AS SPECIFIED OD ALLOWED BY EQUAL SUBSTITUTION.
B. WIRING DEVICES SHALL CONFORM TO NEMA WD 1.
C. WALL SWITCHES SHALL BE NEMA WD 1 GENERAL DUTY, AC ONLY GENERAL USE SNAP SWITCH. RATED FOR
120/277 VOLTS/20 AMPS.
D. RECEPTACLES SHALL BE NEMA WD 6, TAMPER RESISTANT, PLASTIC BODY, 120 VOLTS, 20 AMPS, TYPE 5-20, UL 498 AND CSA C22.2, #42 LISTED.
E. GFCI RECEPTACLES SHALL BE EQUIPPED WITH INTEGRAL GROUND-FAULT-CIRCUIT INTERRUPTER.
F. COVER PLATES SHALL BE NYLON UNLESS OTHERWISE DIRECTED BY OWNER. COLOR SHALL MATCH
DEVICES.
G. COORDINATE DEVICE COLORS WITH OWNER PRIOR TO ORDERING MATERIALS.
H. PROVIDE PRODUCT DATA SUBMITTALS.
ELECTRICAL SPECIFICATIONS
E100
ELECTRICAL LEGEND
LIGHT FIXTURE SCHEDULE
AutoCAD SHX Text
AutoCAD SHX Text
GARDEN BUILDING TYPE "B" FIRST FLOOR PLAN
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
GARDEN BUILDING TYPE "A" FIRST FLOOR PLAN
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text CONFLICTS TO ENGINEER BEFORE CONTINUING WITH WORK. UNLESS INDICATED OTHERWISE. & NEMA AND SHALL BE UL LISTED. SPACES AND SURFACE LIQUID-TIGHT FLEXIBLE METAL SCHEDULE 40 PVC. AND APPLICATION. FITTINGS SHALL CONFORM TO UL 514B. COMPLY WITH UL 486A. AND MC CABLE WHERE AND INSTALLATION OF SUPPORTS WALLS AND FLOORS. APPLY UL LISTED LAMINATE FOR METER SOCKETS, ARC-FAULT BREAKERS USE SNAP SWITCH. RATED FOR VOLTS, 20 AMPS, TYPE 5-20, COLOR SHALL MATCH
AutoCAD SHX Text
EXISTING ELECTRICAL PANEL, 120/240 VOLT, 1-PHASE
AutoCAD SHX Text
NON-FUSED DISCONNECT SWITCH
AutoCAD SHX Text
SINGLE-POLE SWITCH; MOUNT AT 48" AFF
AutoCAD SHX Text
3-WAY SWITCH; MOUNT AT 48" AFF
AutoCAD SHX Text
TAMPER RESISTANT DUPLEX RECEPTACLE; MOUNT AT 48" AFF UNLESS OTHERWISE SPECIFIED.
AutoCAD SHX Text
FUSED DISCONNECT SWITCH
AutoCAD SHX Text
JUNCTION BOX, ACCORDING TO NEC REQUIREMENTS
AutoCAD SHX Text J
AutoCAD SHX Text
SURFACE MOUNTED CEILING; SUBLETTER INDICATES FIXTURE TYPE
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
PROVIDE GFCI PROTECTION WHERE NOTED.
AutoCAD SHX Text 8" ROUND CEILING MOUNT GLOBE, FURNISH WITH (2) A19 LED LAMPS, 850 LUMEN MINIMUM, 3500K: HD SUPPLY #322214
AutoCAD SHX Text C1
AutoCAD SHX Text 6" ROUND CEILING MOUNT GLOBE, FURNISH WITH (1) A19 LED LAMP, 850 LUMEN MINIMUM, 3500K: HD SUPPLY #322212
AutoCAD SHX Text C2
AutoCAD SHX Text
240V, 50A, 2-POLE RANGE RECEPTACLE;
APARTMENT
TYPE 4 APARTMENT
TYPE 3 APARTMENT
TYPE 2
APARTMENT
TYPE 4 (M)
APARTMENT
TYPE 3 (M)
APARTMENT
TYPE 2 (M)
APARTMENT
TYPE 7
APARTMENT
TYPE 6
APARTMENT
TYPE 7 (M)
APARTMENT
TYPE 6 (M)
APARTMENT
TYPE 5
APARTMENT
TYPE 2
APARTMENT
TYPE 5 (M)
APARTMENT
TYPE 2 (M)
Drawing Title:Revised By:Date:Description:Revision:Project Title: Date:
Scale:
Drawn By:
Project Number:
Drawing Number:
03/06/2026
25-256
- -WALLINGFORD HOUSING AUTHORITY:
ULBRICH HEIGHTS COMPLEX KITCHEN RENOVATIONS
WHARTON BROOK DR., LOUIS CIRCLE, & TREMPER DR.
WALLINGFORD, CT 06492
AS INDICATED
SILVER
203 230 9007
3190 WHITNEY AVENUE HAMDEN
silverpetrucelli.com
CT 06320
ASSOCIATESPETRUCELLI +
CT 06518
311 STATE STREET NEW LONDON
Project Phase:
State Project Number:
ISSUED FOR BID
OVERALL GARDEN BUILDING
TYPES C, D, & E
DJT
E101
AutoCAD SHX Text
AutoCAD SHX Text
GARDEN BUILDING TYPE "C" FIRST FLOOR PLAN
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
GARDEN BUILDING TYPE "D" FIRST FLOOR PLAN
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
GARDEN BUILDING TYPE "E" FIRST FLOOR PLAN
1/8"=1'-0"
7 25
A
C
GFA
D
H
G
E G
B
C
A
C
B
C
B
G
AG
G
E
D
H
(NOT ALL NOTE APPLY TO THIS SHEET)
REMOVE RECEPTACLE AND COVER PLATE. REPLACE WITH NEW TYPE AS
INDICATED ON NEW WORK PLAN. REUSE BACK BOX AND WIRING SHALL
BE MADE SAFE UNTIL NEW WORK RECEPTACLE INSTALLATION IS
COMPLETE.
REMOVE RECEPTACLE, BACK BOX, AND ALL ASSOCIATED WIRING.
REWORK WIRING AS REQUIRED TO KEEP CONTINUITY WITH ANY ACTIVE
DOWNSTREAM DEVICES.
REMOVE RANGE RECEPTACLE AND COVER PLATE. MAKE SAFE AND
REUSE BRANCH CIRCUIT WIRING AND 50A, 2-POLE CIRCUIT BREAKER.
REMOVE RANGE RECEPTACLE, BACK BOX, AND ASSOCIATED WIRING IN
ITS ENTIRETY BACK TO 50A, 2-POLE CIRCUIT BREAKER IN BASEMENT
PANEL. REFER TO ELEC NEW WORK PLAN FOR NEW RANGE RECEPTACLE
LOCATION AND REQUIREMENTS.
REMOVE REFRIGERATOR RECEPTACLE, COVER PLATE AND BACK BOX.
REPLACE WITH NEW TYPE IN LOCATION AS INDICATED ON NEW WORK
PLAN. WIRING SHALL BE MADE SAFE AND REUSED. EXTENDED/ALTER
WIRING TO NEW LOCATION AS REQUIRED.
REMOVE CEILING MOUNTED LIGHT FIXTURE. REPLACE WITH NEW TYPE
AS INDICATED ON NEW WORK PLAN. REUSE BACK BOX AND WIRING
SHALL BE MADE SAFE UNTIL NEW WORK LIGHT FIXTURE INSTALLATION IS
COMPLETE.
REMOVE 3-WAY TOGGLE SWITCH AND COVER PLATE. REPLACE WITH
NEW TYPE AS INDICATED ON NEW WORK PLAN. REUSE BACK BOX AND
WIRING SHALL BE MADE SAFE UNTIL NEW WORK SWITCH INSTALLATION IS
COMPLETE.
REMOVE SINGLE POLE TOGGLE SWITCH AND COVER PLATE. REPLACE
WITH NEW TYPE AS INDICATED ON NEW WORK PLAN. REUSE BACK BOX
AND WIRING SHALL BE MADE SAFE UNTIL NEW WORK SWITCH
INSTALLATION IS COMPLETE.
(NOT ALL NOTE APPLY TO THIS SHEET)
FURNISH AND INSTALL GFCI, TAMPER-RESISTANT RECEPTACLE AND
COVER PLATE IN EXISTING BACK BOX AND TERMINATE TO EXISTING
WIRING.
FURNISH AND INSTALL CEILING MOUNTED LIGHT FIXTURE, OF TYPE AS
INDICATED, AND TERMINATE TO EXISTING WIRING. REFER TO LIGHT
FIXTURE SCHEDULE ON SHEET E001 FOR ADDITIONAL INFORMATION AND
REQUIREMENTS.
FURNISH AND INSTALL 3-WAY TOGGLE SWITCH AND COVER PLATE IN
EXISTING BACK BOX AND TERMINATE TO EXISTING WIRING. TEST
SWITCHES TO ENSURE THAT 3-WAY CONTROLS ARE WORKING PROPERLY
WITH LIGHT FIXTURE.
FURNISH AND INSTALL 50A, 240V, 4-WIRE RANGE RECEPTACLE IN
LOCATION PER APPROVED RANGE MANUFACTURER'S REQUIREMENTS.
EXTENDED/ALTER EXISTING WIRING AND TERMINATE TO RECEPTACLE.
FURNISH AND INSTALL GFCI, TAMPER-PROOF REFRIGERATOR
RECEPTACLE IN LOCATION PER APPROVED REFRIGERATOR
MANUFACTURER'S REQUIREMENTS. EXTENDED/ALTER EXISTING WIRING
AND TERMINATE TO RECEPTACLE.
FURNISH AND INSTALL SINGLE POLE TOGGLE SWITCH AND COVER PLATE
IN EXISTING BACK BOX AND TERMINATE TO EXISTING WIRING.
FURNISH AND INSTALL GFCI, TAMPER-PROOF RECEPTACLE, OF TYPE AS
INDICATED, IN THIS LOCATION. EXTEND/ALTER EXISTING KITCHEN
RECEPTACLE BRANCH CIRCUIT WRING AND TERMINATE TO RECEPTACLE.
FURNISH AND INSTALL RECESSED J-BOX IN WALL IN LOCATION AS
REQUIRED PER APPROVED RANGE HOOD MANUFACTURER'S
REQUIREMENTS. WIRE RANGE HOOD FROM LOAD SIDE OF EXISTING
KITCHEN GFI RECEPTACLE CIRCUIT.
A
B
C
D
E
F
G
H
F B
DEMOLITION NOTES
CONSTRUCTION NOTES
ONLY THE FOLLOWING UNITS:
TYPE 3 = 324B, 27B, 37B, 38B, 21, & 33
TYPE 3 (M) = 324E, 32E, 15, 27, & 32
TYPE 3-1 = 27D & 26
ONLY THE FOLLOWING UNITS:
TYPE 2 = 324C, 25B, 27C, 29B, 31C, 32C, 37C, 39B, 31 & 42
TYPE 2 (M) = 25C, 29C, 31D, 32D, 35C, 37D, 38D, 39C, & 29
TYPE 2-1 = 28
ONLY THE FOLLOWING UNITS:
TYPE 3 = 324B, 27B, 37B, 38B, 21, & 33
TYPE 3 (M) = 324E, 32E, 15, 27, & 32
TYPE 3-1 = 27D & 26
ONLY THE FOLLOWING UNITS:
TYPE 2 = 324C, 25B, 27C, 29B, 31C, 32C, 37C, 39B, 31 & 42
TYPE 2 (M) = 25C, 29C, 31D, 32D, 35C, 37D, 38D, 39C, & 29
TYPE 2-1 = 28
Drawing Title:Revised By:Date:Description:Revision:Project Title: Date:
Scale:
Drawn By:
Project Number:
Drawing Number:
03/06/2026
25-256
- -WALLINGFORD HOUSING AUTHORITY:
ULBRICH HEIGHTS COMPLEX KITCHEN RENOVATIONS
WHARTON BROOK DR., LOUIS CIRCLE, & TREMPER DR.
WALLINGFORD, CT 06492
AS INDICATED
SILVER
203 230 9007
3190 WHITNEY AVENUE HAMDEN
silverpetrucelli.com
CT 06320
ASSOCIATESPETRUCELLI +
CT 06518
311 STATE STREET NEW LONDON
Project Phase:
State Project Number:
ISSUED FOR BID
TYPICAL UNIT LAYOUT
TYPES 2, 2-1, 3, & 3-1
ELECTRICAL
DJT
E102
AutoCAD SHX Text
AutoCAD SHX Text
UNIT TYPES 2 & 2-1 - FIRST FLOOR
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
UNIT TYPES 3 & 3-1 - FIRST FLOOR
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
UNIT TYPE 2 & 2-1 - DEMOLITION PLAN
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
UNIT TYPE 3 & 3-1 - DEMOLITION PLAN
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text C1
AutoCAD SHX Text C2
AutoCAD SHX Text J
AutoCAD SHX Text C1
AutoCAD SHX Text C2
AutoCAD SHX Text J
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
S
(NOT ALL NOTE APPLY TO THIS SHEET)
REMOVE RECEPTACLE AND COVER PLATE. REPLACE WITH NEW TYPE AS
INDICATED ON NEW WORK PLAN. REUSE BACK BOX AND WIRING SHALL
BE MADE SAFE UNTIL NEW WORK RECEPTACLE INSTALLATION IS
COMPLETE.
REMOVE RECEPTACLE, BACK BOX, AND ALL ASSOCIATED WIRING.
REWORK WIRING AS REQUIRED TO KEEP CONTINUITY WITH ANY ACTIVE
DOWNSTREAM DEVICES.
REMOVE RANGE RECEPTACLE AND COVER PLATE. MAKE SAFE AND
REUSE BRANCH CIRCUIT WIRING AND 50A, 2-POLE CIRCUIT BREAKER.
REMOVE RANGE RECEPTACLE, BACK BOX, AND ASSOCIATED WIRING IN
ITS ENTIRETY BACK TO 50A, 2-POLE CIRCUIT BREAKER IN BASEMENT
PANEL. REFER TO ELEC NEW WORK PLAN FOR NEW RANGE RECEPTACLE
LOCATION AND REQUIREMENTS.
REMOVE REFRIGERATOR RECEPTACLE, COVER PLATE AND BACK BOX.
REPLACE WITH NEW TYPE IN LOCATION AS INDICATED ON NEW WORK
PLAN. WIRING SHALL BE MADE SAFE AND REUSED. EXTENDED/ALTER
WIRING TO NEW LOCATION AS REQUIRED.
REMOVE CEILING MOUNTED LIGHT FIXTURE. REPLACE WITH NEW TYPE
AS INDICATED ON NEW WORK PLAN. REUSE BACK BOX AND WIRING
SHALL BE MADE SAFE UNTIL NEW WORK LIGHT FIXTURE INSTALLATION IS
COMPLETE.
REMOVE 3-WAY TOGGLE SWITCH AND COVER PLATE. REPLACE WITH
NEW TYPE AS INDICATED ON NEW WORK PLAN. REUSE BACK BOX AND
WIRING SHALL BE MADE SAFE UNTIL NEW WORK SWITCH INSTALLATION IS
COMPLETE.
REMOVE SINGLE POLE TOGGLE SWITCH AND COVER PLATE. REPLACE
WITH NEW TYPE AS INDICATED ON NEW WORK PLAN. REUSE BACK BOX
AND WIRING SHALL BE MADE SAFE UNTIL NEW WORK SWITCH
INSTALLATION IS COMPLETE.
DEMOLITION NOTES
CONSTRUCTION NOTES
(NOT ALL NOTE APPLY TO THIS SHEET)
FURNISH AND INSTALL GFCI, TAMPER-RESISTANT RECEPTACLE AND
COVER PLATE IN EXISTING BACK BOX AND TERMINATE TO EXISTING
WIRING.
FURNISH AND INSTALL CEILING MOUNTED LIGHT FIXTURE, OF TYPE AS
INDICATED, AND TERMINATE TO EXISTING WIRING. REFER TO LIGHT
FIXTURE SCHEDULE ON SHEET E001 FOR ADDITIONAL INFORMATION AND
REQUIREMENTS.
FURNISH AND INSTALL 3-WAY TOGGLE SWITCH AND COVER PLATE IN
EXISTING BACK BOX AND TERMINATE TO EXISTING WIRING. TEST
SWITCHES TO ENSURE THAT 3-WAY CONTROLS ARE WORKING PROPERLY
WITH LIGHT FIXTURE.
FURNISH AND INSTALL 50A, 240V, 4-WIRE RANGE RECEPTACLE IN
LOCATION PER APPROVED RANGE MANUFACTURER'S REQUIREMENTS.
EXTENDED/ALTER EXISTING WIRING AND TERMINATE TO RECEPTACLE.
FURNISH AND INSTALL GFCI, TAMPER-PROOF REFRIGERATOR
RECEPTACLE IN LOCATION PER APPROVED REFRIGERATOR
MANUFACTURER'S REQUIREMENTS. EXTENDED/ALTER EXISTING WIRING
AND TERMINATE TO RECEPTACLE.
FURNISH AND INSTALL SINGLE POLE TOGGLE SWITCH AND COVER PLATE
IN EXISTING BACK BOX AND TERMINATE TO EXISTING WIRING.
FURNISH AND INSTALL GFCI, TAMPER-PROOF RECEPTACLE, OF TYPE AS
INDICATED, IN THIS LOCATION. EXTEND/ALTER EXISTING KITCHEN
RECEPTACLE BRANCH CIRCUIT WIRING AND TERMINATE TO RECEPTACLE.
FURNISH AND INSTALL RECESSED J-BOX IN WALL IN LOCATION AS
REQUIRED PER APPROVED RANGE HOOD MANUFACTURER'S
REQUIREMENTS. WIRE RANGE HOOD FROM LOAD SIDE OF EXISTING
KITCHEN GFI RECEPTACLE CIRCUIT.
A
B
C
D
E
F
G
H
A
A
A
D
HB
C
C
F
B
G
G E
6 6
E G
G
G
C
B
C
B
F
D HA
A
ONLY THE FOLLOWING UNITS:
TYPE 5 = 25A, 29A, 35A, & 39A
TYPE 5 (M) = 25D & 29D
ONLY THE FOLLOWING UNITS:
TYPE 5 = 25A, 29A, 35A, & 39A
TYPE 5 (M) = 25D & 29D
ONLY THE FOLLOWING UNITS:
TYPE 4 (M) = 48
ONLY THE FOLLOWING UNITS:
TYPE 4 (M) = 48
Drawing Title:Revised By:Date:Description:Revision:Project Title: Date:
Scale:
Drawn By:
Project Number:
Drawing Number:
03/06/2026
25-256
- -WALLINGFORD HOUSING AUTHORITY:
ULBRICH HEIGHTS COMPLEX KITCHEN RENOVATIONS
WHARTON BROOK DR., LOUIS CIRCLE, & TREMPER DR.
WALLINGFORD, CT 06492
AS INDICATED
SILVER
203 230 9007
3190 WHITNEY AVENUE HAMDEN
silverpetrucelli.com
CT 06320
ASSOCIATESPETRUCELLI +
CT 06518
311 STATE STREET NEW LONDON
Project Phase:
State Project Number:
ISSUED FOR BID DJT
TYPICAL UNIT LAYOUT
TYPES 4 & 5
ELECTRICAL E103
AutoCAD SHX Text
AutoCAD SHX Text
UNIT TYPE 4 - FIRST FLOOR
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
UNIT TYPE 5 - FIRST FLOOR
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
UNIT TYPE 4 - DEMOLITION PLAN
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
UNIT TYPE 5 - DEMOLITION PLAN
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text C1
AutoCAD SHX Text C2
AutoCAD SHX Text J
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text C1
AutoCAD SHX Text C2
AutoCAD SHX Text J
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
(NOT ALL NOTE APPLY TO THIS SHEET)
REMOVE RECEPTACLE AND COVER PLATE. REPLACE WITH NEW TYPE AS
INDICATED ON NEW WORK PLAN. REUSE BACK BOX AND WIRING SHALL
BE MADE SAFE UNTIL NEW WORK RECEPTACLE INSTALLATION IS
COMPLETE.
REMOVE RECEPTACLE, BACK BOX, AND ALL ASSOCIATED WIRING.
REWORK WIRING AS REQUIRED TO KEEP CONTINUITY WITH ANY ACTIVE
DOWNSTREAM DEVICES.
REMOVE RANGE RECEPTACLE AND COVER PLATE. MAKE SAFE AND
REUSE BRANCH CIRCUIT WIRING AND 50A, 2-POLE CIRCUIT BREAKER.
REMOVE RANGE RECEPTACLE, BACK BOX, AND ASSOCIATED WIRING IN
ITS ENTIRETY BACK TO 50A, 2-POLE CIRCUIT BREAKER IN BASEMENT
PANEL. REFER TO ELEC NEW WORK PLAN FOR NEW RANGE RECEPTACLE
LOCATION AND REQUIREMENTS.
REMOVE REFRIGERATOR RECEPTACLE, COVER PLATE AND BACK BOX.
REPLACE WITH NEW TYPE IN LOCATION AS INDICATED ON NEW WORK
PLAN. WIRING SHALL BE MADE SAFE AND REUSED. EXTENDED/ALTER
WIRING TO NEW LOCATION AS REQUIRED.
REMOVE CEILING MOUNTED LIGHT FIXTURE. REPLACE WITH NEW TYPE
AS INDICATED ON NEW WORK PLAN. REUSE BACK BOX AND WIRING
SHALL BE MADE SAFE UNTIL NEW WORK LIGHT FIXTURE INSTALLATION IS
COMPLETE.
REMOVE 3-WAY TOGGLE SWITCH AND COVER PLATE. REPLACE WITH
NEW TYPE AS INDICATED ON NEW WORK PLAN. REUSE BACK BOX AND
WIRING SHALL BE MADE SAFE UNTIL NEW WORK SWITCH INSTALLATION IS
COMPLETE.
REMOVE SINGLE POLE TOGGLE SWITCH AND COVER PLATE. REPLACE
WITH NEW TYPE AS INDICATED ON NEW WORK PLAN. REUSE BACK BOX
AND WIRING SHALL BE MADE SAFE UNTIL NEW WORK SWITCH
INSTALLATION IS COMPLETE.
DEMOLITION NOTES
CONSTRUCTION NOTES
(NOT ALL NOTE APPLY TO THIS SHEET)
FURNISH AND INSTALL GFCI, TAMPER-RESISTANT RECEPTACLE AND
COVER PLATE IN EXISTING BACK BOX AND TERMINATE TO EXISTING
WIRING.
FURNISH AND INSTALL CEILING MOUNTED LIGHT FIXTURE, OF TYPE AS
INDICATED, AND TERMINATE TO EXISTING WIRING. REFER TO LIGHT
FIXTURE SCHEDULE ON SHEET E001 FOR ADDITIONAL INFORMATION AND
REQUIREMENTS.
FURNISH AND INSTALL 3-WAY TOGGLE SWITCH AND COVER PLATE IN
EXISTING BACK BOX AND TERMINATE TO EXISTING WIRING. TEST
SWITCHES TO ENSURE THAT 3-WAY CONTROLS ARE WORKING PROPERLY
WITH LIGHT FIXTURE.
FURNISH AND INSTALL 50A, 240V, 4-WIRE RANGE RECEPTACLE IN
LOCATION PER APPROVED RANGE MANUFACTURER'S REQUIREMENTS.
EXTENDED/ALTER EXISTING WIRING AND TERMINATE TO RECEPTACLE.
FURNISH AND INSTALL GFCI, TAMPER-PROOF REFRIGERATOR
RECEPTACLE IN LOCATION PER APPROVED REFRIGERATOR
MANUFACTURER'S REQUIREMENTS. EXTENDED/ALTER EXISTING WIRING
AND TERMINATE TO RECEPTACLE.
FURNISH AND INSTALL SINGLE POLE TOGGLE SWITCH AND COVER PLATE
IN EXISTING BACK BOX AND TERMINATE TO EXISTING WIRING.
FURNISH AND INSTALL GFCI, TAMPER-PROOF RECEPTACLE, OF TYPE AS
INDICATED, IN THIS LOCATION. EXTEND/ALTER EXISTING KITCHEN
RECEPTACLE BRANCH CIRCUIT WRING AND TERMINATE TO RECEPTACLE.
FURNISH AND INSTALL RECESSED J-BOX IN WALL IN LOCATION AS
REQUIRED PER APPROVED RANGE HOOD MANUFACTURER'S
REQUIREMENTS. WIRE RANGE HOOD FROM LOAD SIDE OF EXISTING
KITCHEN GFI RECEPTACLE CIRCUIT.
A
B
C
D
E
F
G
H
6 6
E G
G
G
C
B
C
B
F
D HA
A
A
C
B
C
B
G
AG
G
E
D
H
F
ONLY THE FOLLOWING UNITS:
TYPE 7 = 49
TYPE 7 (M) = 43
ONLY THE FOLLOWING UNITS:
TYPE 7 = 49
TYPE 7 (M) = 43
ONLY THE FOLLOWING UNITS:
TYPE 6 = 7
TYPE 6 (M) = 5 & 45
ONLY THE FOLLOWING UNITS:
TYPE 6 = 7
TYPE 6 (M) = 5 & 45
Drawing Title:Revised By:Date:Description:Revision:Project Title: Date:
Scale:
Drawn By:
Project Number:
Drawing Number:
03/06/2026
25-256
- -WALLINGFORD HOUSING AUTHORITY:
ULBRICH HEIGHTS COMPLEX KITCHEN RENOVATIONS
WHARTON BROOK DR., LOUIS CIRCLE, & TREMPER DR.
WALLINGFORD, CT 06492
AS INDICATED
SILVER
203 230 9007
3190 WHITNEY AVENUE HAMDEN
silverpetrucelli.com
CT 06320
ASSOCIATESPETRUCELLI +
CT 06518
311 STATE STREET NEW LONDON
Project Phase:
State Project Number:
ISSUED FOR BID DJT
TYPICAL UNIT LAYOUT
TYPES 6 & 7
ELECTRICAL E104
AutoCAD SHX Text
AutoCAD SHX Text
UNIT TYPE 6 - FIRST FLOOR
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
UNIT TYPE 7 - FIRST FLOOR
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
UNIT TYPE 6 - DEMOLITION PLAN
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
UNIT TYPE 7 - DEMOLITION PLAN
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text C1
AutoCAD SHX Text C2
AutoCAD SHX Text J
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text C1
AutoCAD SHX Text C2
AutoCAD SHX Text J
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
File details come from the government source that posted it. Updated .