25-26-56 North Rec Complex Improvements Bid Document.pdf
PDF 40 MB Posted
- Attached to
- 25-26-56
- Solicitation number
- 311-25-26-56
- Issued by
- Randolph County, Hallsboro CDP, North Carolina
About this file
This is a bid document package for the ECU North Recreation Complex Improvements project prepared by the City of Greenville, North Carolina. The project, identified as SCO ID #26-31196-01A, involves comprehensive site improvements including demolition, grading, storm drainage installation, erosion control, and athletic field construction at 3764 US 264 East in Greenville. The work encompasses site clearing and demolition of existing structures, installation of new storm drainage systems (including HDPE and RCP piping ranging from 12" to 36" diameter), grading and site preparation, temporary and permanent erosion and sediment control measures, concrete washout facilities, tree protection, and seeding and mulching of disturbed areas. A non-mandatory pre-bid meeting is scheduled for Tuesday, July 14, 2026, at 2:00 pm at the Jayce Park Administration Building, 2000 Cedar Lane, Greenville, North Carolina. The bid was issued for bidding on June 19, 2026, with inquiry questions to be directed to Mark Nottingham, City Projects & Development Manager, at 252.329.4242 or mnottingham@greenvillenc.gov.
The construction documents include detailed civil engineering plans with specifications for grading, drainage, erosion control per the NCG01 Construction General Permit, and site details prepared by Kimley-Horn and Associates, Inc. The project requires contractor compliance with North Carolina Department of Environmental Quality standards, City of Greenville design and construction standards, NCDOT specifications, and geotechnical requirements as outlined in the preliminary geotechnical engineering report prepared by Terracon dated November 20, 2025. The contractor is responsible for verifying all existing utility locations by contacting NC811 at least 48 hours prior to excavation, obtaining all necessary permits, conducting a pre-construction conference with City of Greenville Engineering Division, maintaining erosion control measures during construction, and providing as-built plans upon completion. Site improvements include parking facilities with 407 total spaces (including 10 ADA spaces), temporary sediment basins with porous baffles, silt fencing, construction entrances, and stabilized outlets for proper stormwater management throughout the phased construction process.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 25.26-56 Project Manual - North Recreation Complex Improvements.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X
FO FO
FO
FO
FO
FO
FO
FO
FO
FO
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
T h is d o c u m e n t, t o g e th e r w it h t h e c o n c e p ts a n d d e s ig n s p re s e n te d h e re in a s a n i n s tr u m e n t o f s e rv ic e is i n te n d e d o n ly f o r th e s p e c if ic p u rp o s e a n d c lie n t fo r w h ic h i t w a s p re p a re d
R e u s e o f a n d i m p ro p e r re lia n c e o n t h is d o c u m e n t w it h o u t w ri tt e n a u th o ri z a ti o n a n d a d a p ta ti o n b y K im le y -H o rn a n d A s s o c ia te s
In c s h a ll b e w it h o u t lia b ili ty t o K im le y -H o rn a n d A s s o c ia te s
In c
SHEET NUMBER
KI
M
LE
Y-
H O
R N
A N
D A
SS
O
C
IA
TE
S, IN
C
Know what's below.
before you dig.Call
R
SURVEY NOTE:
EXISTING TOPOGRAPHICAL INFORMATION IS BASED ON A
BOUNDARY AND TOPOGRAPHIC SURVEY OBTAINED ON 11/14/2025.
CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL
EXISTING INFORMATION, DEPICTED OR NOT, PRIOR TO
CONSTRUCTION AND REPORT POTENTIAL CONFLICTS TO OWNER
AND ENGINEER.
GEOTECH NOTE:
GEOTECHNICAL BORING INFORMATION WAS PROVIDED WITHIN A
PRELIMINARY GEOTECHNICAL ENGINEERING REPORT PREPARED
BY TERRACON, 252-353-1600, DATED 11/20/2025.
#F -0
W W
W .K
IM
LE
Y- H
O R
N .C
O M
P H
O N
E:
-6
-2
FA
X:
-6
-2
FA
YE
TT
EV
IL
LE
S
TR
EE
T, S
U
IT
E
0, R
AL
EI
G H
, N C
EC
U
N O
R
TH
R
EC
R
EA
TI
O
N C
O M
PL
EX
PR
EP
AR
ED
F O
R
C
IT
Y O
F G
R
EE
N
VI
LL
E
G R
EE
N
VI
LL
E, N
C
U S
EA
ST
D
AT
E
AS
S
H O
W N
C H
EC
KE
D B
Y
SC
AL
E
D
ES
IG
N
ED
B
Y
D R
AW
N
B Y
TE
G
P R
O J
CITY OF GREENVILLE SITE PLAN APPROVAL
DATE: ____________
APPROVED
ZONING
SURVEYOR / FLOODPLAIN
FIRE / RESCUE
GUC WATER / SEWER
NCDOT
TRAFFIC SERVICES
*SITE PLAN APPROVAL ONLY. ENGINEER / ARCHITECT / SURVEYOR SHALL BE RESPONSIBLE FOR ADEQUACY OF DESIGN, ERRORS OR OMISSIONS IN THE PLANS. ALL PLANS SHALL MEET ALL SPECIFICATIONS, STANDARDS AND
APPLICABLE REGULATIONS.
APPROVED AS NOTED __________________
ENGINEERING
INSPECTIONS
GUC ELECTRIC
GUC GAS
VEGETATION
NOTES
BY
R
EV
IS
IO
N
S N o.
D
AT
E
CO
RP
O
RA
TE
O
FF
IC
E
Ev an s S tr ee t Gr ee nv ill e, N C
Te l 2
.7
.3
N C
Ar ch ite ct ur al
L ic en se
N o.
N
C In te rio r D es ig n
Li ce ns e
N o.
N
C En gi ne er in g Li ce ns e N o.
C
-0
N
C La nd sc ap e
Ar ch ite ct ur al
L ic en se
N o.
C -4 ea st gr ou p.
co m
SC
O
ID
-3
-0 1A
SC
O
C O
M M
EN
T
R
ES
U
BM
IT
TA
L
/2 2/
AH
IS
SU
E
FO
R B
ID
/1 9/
AH
C
O
VE
R
C000
/0
6/
AH BR
N
SCALE 1"=80'
80'0'40'80'ECU NORTH RECREATION
COMPLEX
ISSUE FOR SCO REVIEW
GREENVILLE, NC
SCO ID NO. 26-31196-01A
TEG PROJECT NO. 20250259
DRAWING INDEX
SHEET
NUMBER
SHEET TITLE
C000 COVER
CIVIL
C002 DEMOLITION & EROSION CONTROL PLAN
C100 PHASE 1 EROSION CONTROL PLAN
C101 PHASE 2 EROSION CONTROL PLAN
C102 GROUND STABILIZATION AND MATERIALS HANDLING
C103 SELF-INSPECTION, RECORDKEEPING AND REPORTING NOTES
C104 EROSION CONTROL DETAILS
C200 SITE PLAN
C300 GRADING PLAN
C800 SITE DETAILS
X X X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
LIMIT OF DISTURBANCE
LIMIT OF
DISTURBANCE
LIMIT OF DISTURBANCE
LIMIT OF DISTURBANCE
DEMOLISH
TREE, TYP
DEMOLISH EXISTING CONCRETE
SAW CUT TO NEAREST
EXISTING CONCRETE JOINT
SAW CUT TO NEAREST
EXISTING CONCRETE JOINT
DEMOLISH EXISTING CONCRETE
DEMOLISH
TREE, TYP
50' CONSTRUCTION
ENTRANCE
ALL STORM STRUCTURES
AND PIPING IN THIS AREA TO
BE REMOVED
ALL STORM STRUCTURES
AND PIPING IN THIS AREA TO
BE REMOVED
ALL STORM STRUCTURES
AND PIPING IN THIS AREA TO
BE REMOVED
ALL STORM STRUCTURES
AND PIPING IN THIS AREA TO
BE REMOVED
ALL STORM PIPING IN THIS
AREA TO BE ABANDONED IN
PLACE AND FILLED w/
FLOWABLE FILL
ALL STORM PIPING IN THIS
AREA TO BE ABANDONED IN
PLACE AND FILLED w/
FLOWABLE FILL
ABANDONED PIPES
TO BE CAPPED
INSIDE EXISTING DI
10' DEMO CORRIDOR FOR
PROPOSED STORM PIPE
T h is d o c u m e n t, t o g e th e r w it h t h e c o n c e p ts a n d d e s ig n s p re s e n te d h e re in a s a n i n s tr u m e n t o f s e rv ic e is i n te n d e d o n ly f o r th e s p e c if ic p u rp o s e a n d c lie n t fo r w h ic h i t w a s p re p a re d
R e u s e o f a n d i m p ro p e r re lia n c e o n t h is d o c u m e n t w it h o u t w ri tt e n a u th o ri z a ti o n a n d a d a p ta ti o n b y K im le y -H o rn a n d A s s o c ia te s
In c s h a ll b e w it h o u t lia b ili ty t o K im le y -H o rn a n d A s s o c ia te s
In c
SHEET NUMBER
KI
M
LE
Y-
H O
R N
A N
D A
SS
O
C
IA
TE
S, IN
C
Know what's below.
before you dig.Call
R
SURVEY NOTE:
EXISTING TOPOGRAPHICAL INFORMATION IS BASED ON A
BOUNDARY AND TOPOGRAPHIC SURVEY OBTAINED ON 11/14/2025.
CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL
EXISTING INFORMATION, DEPICTED OR NOT, PRIOR TO
CONSTRUCTION AND REPORT POTENTIAL CONFLICTS TO OWNER
AND ENGINEER.
GEOTECH NOTE:
GEOTECHNICAL BORING INFORMATION WAS PROVIDED WITHIN A
PRELIMINARY GEOTECHNICAL ENGINEERING REPORT PREPARED
BY TERRACON, 252-353-1600, DATED 11/20/2025.
#F -0
W W
W .K
IM
LE
Y- H
O R
N .C
O M
P H
O N
E:
-6
-2
FA
X:
-6
-2
FA
YE
TT
EV
IL
LE
S
TR
EE
T, S
U
IT
E
0, R
AL
EI
G H
, N C
EC
U
N O
R
TH
R
EC
R
EA
TI
O
N C
O M
PL
EX
PR
EP
AR
ED
F O
R
C
IT
Y O
F G
R
EE
N
VI
LL
E
G R
EE
N
VI
LL
E, N
C
U S
EA
ST
D
AT
E
AS
S
H O
W N
C H
EC
KE
D B
Y
SC
AL
E
D
ES
IG
N
ED
B
Y
D R
AW
N
B Y
TE
G
P R
O J
CITY OF GREENVILLE SITE PLAN APPROVAL
DATE: ____________
APPROVED
ZONING
SURVEYOR / FLOODPLAIN
FIRE / RESCUE
GUC WATER / SEWER
NCDOT
TRAFFIC SERVICES
*SITE PLAN APPROVAL ONLY. ENGINEER / ARCHITECT / SURVEYOR SHALL BE RESPONSIBLE FOR ADEQUACY OF DESIGN, ERRORS OR OMISSIONS IN THE PLANS. ALL PLANS SHALL MEET ALL SPECIFICATIONS, STANDARDS AND
APPLICABLE REGULATIONS.
APPROVED AS NOTED __________________
ENGINEERING
INSPECTIONS
GUC ELECTRIC
GUC GAS
VEGETATION
NOTES
BY
R
EV
IS
IO
N
S N o.
D
AT
E
CO
RP
O
RA
TE
O
FF
IC
E
Ev an s S tr ee t Gr ee nv ill e, N C
Te l 2
.7
.3
N C
Ar ch ite ct ur al
L ic en se
N o.
N
C In te rio r D es ig n
Li ce ns e
N o.
N
C En gi ne er in g Li ce ns e N o.
C
-0
N
C La nd sc ap e
Ar ch ite ct ur al
L ic en se
N o.
C -4 ea st gr ou p.
co m
SC
O
ID
-3
-0 1A
SC
O
C O
M M
EN
T
R
ES
U
BM
IT
TA
L
/2 2/
AH
IS
SU
E
FO
R B
ID
/1 9/
AH
D
EM
O
LI
TI
O
N
ER
O
SI
O
N C
O N
TR
O
L
PL
AN
C002
/0
6/
AF BR
N
SCALE 1"=40'
40'0'40' 20'
C002
DEMOLITION PLAN
SCALE: 1" = 40'
EXISTING ASHPALT DEMOLITION
EXISTING CURB & GUTTER DEMOLITION
EXISTING CONCRETE DEMOLITION
RECLAIM EXISTING BRICKS
EXISTING BUILDING DEMOLITION, SEE ARCH PLANS
EXISTING TREE DEMOLITION
EXISTING SITE FEATURE DEMOLITION
SILT FENCE
SITE DEMOLITION LEGEND GENERAL NOTES
1. GENERAL CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL UTILITY
SERVICES, DRAINAGE, ETC., TO THIS AREA OR ADJACENT AREAS DURING
DEMOLITION AND CONSTRUCTION.
2. ALL DEBRIS FROM DEMOLITION ACTIVITIES SHALL BE REMOVED FROM THE
SITE AND DISPOSED OF PROPERLY IN ACCORDANCE WITH ALL AGENCIES
HAVING JURISDICTION.
1. BACKFILL ALL REMOVED UTILITY TRENCHES, TREE REMOVAL, ETC.
WITH SELECT FILL, COMPACTED TO 95% STANDARD PROCTOR.
2. CONTRACTOR IS RESPONSIBLE FOR CLEAN OUT OF EXISTING STORM
DRAINAGE LOCATED WITHIN THE CONSTRUCTION LIMITS.
3. ALL CONCRETE AND ASPHALT REMOVED SHALL BE SAW CUT OR
REMOVED TO NEXT EXPANSION JOINT.
4. PROVIDE TREE PROTECTION FENCING TO ALL EXISTING TREES
WITHIN 10' OF CONSTRUCTION LIMITS.
5. ROOF DRAINAGE ON ALL ADJACENT BUILDINGS MUST BE MAINTAINED
DURING CONSTRUCTION.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL STORM
WATER DRAINAGE OUTFALLS DURING CONSTRUCTION. G.C. SHALL
COORDINATE CONSTRUCTION OF PROPOSED MAIN DRAINAGE
OUTFALL LINES PRIOR TO DEMOLITION OF EXISTING LINES.
7. NEW STORM DRAINAGE SHALL BE INSTALLED PRIOR TO DEMOLITION
OF EXISTING STORM DRAINAGE, TO THE EXTENT POSSIBLE, TO
PREVENT FLOODING OF EX. FACILITIES.
8. LOCATION OF WATER AND SEWER SERVICES ARE APPROXIMATE AND
SHALL BE VERIFIED PRIOR TO ANY EXCAVATION OCCURRING ON SITE.
9. CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS FROM
DAMAGE DURING CONSTRUCTION AND SHALL RESTORE ANY
DAMAGED IMPROVEMENTS AT THE END OF CONSTRUCTION.
DEMOLITION NOTES
X X X
SF
SFSFSFSF
SF
SFSF
>TD
>TD>TD>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD>TD>TD>TD
>TD>TD>TD>TD>TD>TD>TD>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD >TD >TD >TD >TD >TD >TD >TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
X X X
SILT FENCE
SILT FENCE
SILT FENCE
SILT FENCE
SILT FENCE
ROCK SILT
CHECK DAM
PIPE INLET
PROTECTION
SOIL STOCKPILE,
LOCATION MAY BE
FIELD ADJUSTED
SILT FENCE OUTLET
SILT FENCE
SILT FENCE
10'X10' CONCRETE
WASHOUT WITH SILT FENCE
SILT FENCE
3' CHANNEL BOTTOM
3' CHANNEL WIDTH
±29.1 ±25.1
±20.5 ±15.9
GRAVEL INLET PROTECTION
TEMPORARY
SEDIMENT BASIN
BASIN BAFFLE
3:1 MA
X
3:1 MA
X
3:1 MA
X
3:1 MA
X
SKIMMER
X
X X
X
X
X
X
X
X
X X
X
X X
X X
X X
X
X
X X
X X
X X
X X
X X
X
X
X
XXXX
X
X
X
XX
X
X
X
X X
XXX
X
X
X
X
X
X
X
X X
TEMPORARY
DIVERSION DITCH
TEMPORARY
DIVERSION DITCH
TEMPORARY
DIVERSION DITCH
T h is d o c u m e n t, t o g e th e r w it h t h e c o n c e p ts a n d d e s ig n s p re s e n te d h e re in a s a n i n s tr u m e n t o f s e rv ic e is i n te n d e d o n ly f o r th e s p e c if ic p u rp o s e a n d c lie n t fo r w h ic h i t w a s p re p a re d
R e u s e o f a n d i m p ro p e r re lia n c e o n t h is d o c u m e n t w it h o u t w ri tt e n a u th o ri z a ti o n a n d a d a p ta ti o n b y K im le y -H o rn a n d A s s o c ia te s
In c s h a ll b e w it h o u t lia b ili ty t o K im le y -H o rn a n d A s s o c ia te s
In c
SHEET NUMBER
KI
M
LE
Y-
H O
R N
A N
D A
SS
O
C
IA
TE
S, IN
C
Know what's below.
before you dig.Call
R
SURVEY NOTE:
EXISTING TOPOGRAPHICAL INFORMATION IS BASED ON A
BOUNDARY AND TOPOGRAPHIC SURVEY OBTAINED ON 11/14/2025.
CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL
EXISTING INFORMATION, DEPICTED OR NOT, PRIOR TO
CONSTRUCTION AND REPORT POTENTIAL CONFLICTS TO OWNER
AND ENGINEER.
GEOTECH NOTE:
GEOTECHNICAL BORING INFORMATION WAS PROVIDED WITHIN A
PRELIMINARY GEOTECHNICAL ENGINEERING REPORT PREPARED
BY TERRACON, 252-353-1600, DATED 11/20/2025.
#F -0
W W
W .K
IM
LE
Y- H
O R
N .C
O M
P H
O N
E:
-6
-2
FA
X:
-6
-2
FA
YE
TT
EV
IL
LE
S
TR
EE
T, S
U
IT
E
0, R
AL
EI
G H
, N C
EC
U
N O
R
TH
R
EC
R
EA
TI
O
N C
O M
PL
EX
PR
EP
AR
ED
F O
R
C
IT
Y O
F G
R
EE
N
VI
LL
E
G R
EE
N
VI
LL
E, N
C
U S
EA
ST
D
AT
E
AS
S
H O
W N
C H
EC
KE
D B
Y
SC
AL
E
D
ES
IG
N
ED
B
Y
D R
AW
N
B Y
TE
G
P R
O J
CITY OF GREENVILLE SITE PLAN APPROVAL
DATE: ____________
APPROVED
ZONING
SURVEYOR / FLOODPLAIN
FIRE / RESCUE
GUC WATER / SEWER
NCDOT
TRAFFIC SERVICES
*SITE PLAN APPROVAL ONLY. ENGINEER / ARCHITECT / SURVEYOR SHALL BE RESPONSIBLE FOR ADEQUACY OF DESIGN, ERRORS OR OMISSIONS IN THE PLANS. ALL PLANS SHALL MEET ALL SPECIFICATIONS, STANDARDS AND
APPLICABLE REGULATIONS.
APPROVED AS NOTED __________________
ENGINEERING
INSPECTIONS
GUC ELECTRIC
GUC GAS
VEGETATION
NOTES
BY
R
EV
IS
IO
N
S N o.
D
AT
E
CO
RP
O
RA
TE
O
FF
IC
E
Ev an s S tr ee t Gr ee nv ill e, N C
Te l 2
.7
.3
N C
Ar ch ite ct ur al
L ic en se
N o.
N
C In te rio r D es ig n
Li ce ns e
N o.
N
C En gi ne er in g Li ce ns e N o.
C
-0
N
C La nd sc ap e
Ar ch ite ct ur al
L ic en se
N o.
C -4 ea st gr ou p.
co m
SC
O
ID
-3
-0 1A
SC
O
C O
M M
EN
T
R
ES
U
BM
IT
TA
L
/2 2/
AH
IS
SU
E
FO
R B
ID
/1 9/
AH
PH
AS
E
ER
O
SI
O
N C
O N
TR
O
L
PL
AN
C100
/0
6/
AF BR
N
SCALE 1"=40'
40'0'40' 20'
C100
PHASE 1 EROSION CONTROL PLAN
SCALE: 1" = 40' GENERAL NOTES
1. GENERAL CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL UTILITY
SERVICES, DRAINAGE, ETC., TO THIS AREA OR ADJACENT AREAS DURING
DEMOLITION AND CONSTRUCTION.
2. ALL DEBRIS FROM DEMOLITION ACTIVITIES SHALL BE REMOVED FROM THE
SITE AND DISPOSED OF PROPERLY IN ACCORDANCE WITH ALL AGENCIES
HAVING JURISDICTION.
X X X
SF
SFSFSFSF
SF
SFSF
>TD
>TD>TD>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD>TD>TD>TD
>TD>TD>TD>TD>TD>TD>TD>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD >TD >TD >TD >TD >TD >TD >TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
>TD
X X X
SILT FENCE
SILT FENCE
SILT FENCE
SILT FENCE
SILT FENCE
ROCK SILT
CHECK DAM
PIPE INLET
PROTECTION
SOIL STOCKPILE,
LOCATION MAY BE
FIELD ADJUSTED
SILT FENCE OUTLET
SILT FENCE
SILT FENCE
10'X10' CONCRETE
WASHOUT WITH SILT FENCE
SILT FENCE
3' CHANNEL BOTTOM
3' CHANNEL WIDTH
±29.1 ±25.1
±20.5 ±15.9
GRAVEL INLET PROTECTION
TEMPORARY
SEDIMENT BASIN
BASIN BAFFLE
3:1 MA
X
3:1 MA
X
3:1 MA
X
3:1 MA
X
SKIMMER
X
X X
X
X
X
X
X
X
X X
X
X X
X X
X X
X
X
X X
X X
X X
X X
X X
X
X
X
XXXX
X
X
X
XX
X
X
X
X X
XXX
X
X
X
X
X
X
X
X X
FO FO
FO
FO
FO
FO
FO
FO
FO
FO
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
TEMPORARY
DIVERSION DITCH
TEMPORARY
DIVERSION DITCH
TEMPORARY
DIVERSION DITCH
T h is d o c u m e n t, t o g e th e r w it h t h e c o n c e p ts a n d d e s ig n s p re s e n te d h e re in a s a n i n s tr u m e n t o f s e rv ic e is i n te n d e d o n ly f o r th e s p e c if ic p u rp o s e a n d c lie n t fo r w h ic h i t w a s p re p a re d
R e u s e o f a n d i m p ro p e r re lia n c e o n t h is d o c u m e n t w it h o u t w ri tt e n a u th o ri z a ti o n a n d a d a p ta ti o n b y K im le y -H o rn a n d A s s o c ia te s
In c s h a ll b e w it h o u t lia b ili ty t o K im le y -H o rn a n d A s s o c ia te s
In c
SHEET NUMBER
KI
M
LE
Y-
H O
R N
A N
D A
SS
O
C
IA
TE
S, IN
C
Know what's below.
before you dig.Call
R
SURVEY NOTE:
EXISTING TOPOGRAPHICAL INFORMATION IS BASED ON A
BOUNDARY AND TOPOGRAPHIC SURVEY OBTAINED ON 11/14/2025.
CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL
EXISTING INFORMATION, DEPICTED OR NOT, PRIOR TO
CONSTRUCTION AND REPORT POTENTIAL CONFLICTS TO OWNER
AND ENGINEER.
GEOTECH NOTE:
GEOTECHNICAL BORING INFORMATION WAS PROVIDED WITHIN A
PRELIMINARY GEOTECHNICAL ENGINEERING REPORT PREPARED
BY TERRACON, 252-353-1600, DATED 11/20/2025.
#F -0
W W
W .K
IM
LE
Y- H
O R
N .C
O M
P H
O N
E:
-6
-2
FA
X:
-6
-2
FA
YE
TT
EV
IL
LE
S
TR
EE
T, S
U
IT
E
0, R
AL
EI
G H
, N C
EC
U
N O
R
TH
R
EC
R
EA
TI
O
N C
O M
PL
EX
PR
EP
AR
ED
F O
R
C
IT
Y O
F G
R
EE
N
VI
LL
E
G R
EE
N
VI
LL
E, N
C
U S
EA
ST
D
AT
E
AS
S
H O
W N
C H
EC
KE
D B
Y
SC
AL
E
D
ES
IG
N
ED
B
Y
D R
AW
N
B Y
TE
G
P R
O J
CITY OF GREENVILLE SITE PLAN APPROVAL
DATE: ____________
APPROVED
ZONING
SURVEYOR / FLOODPLAIN
FIRE / RESCUE
GUC WATER / SEWER
NCDOT
TRAFFIC SERVICES
*SITE PLAN APPROVAL ONLY. ENGINEER / ARCHITECT / SURVEYOR SHALL BE RESPONSIBLE FOR ADEQUACY OF DESIGN, ERRORS OR OMISSIONS IN THE PLANS. ALL PLANS SHALL MEET ALL SPECIFICATIONS, STANDARDS AND
APPLICABLE REGULATIONS.
APPROVED AS NOTED __________________
ENGINEERING
INSPECTIONS
GUC ELECTRIC
GUC GAS
VEGETATION
NOTES
BY
R
EV
IS
IO
N
S N o.
D
AT
E
CO
RP
O
RA
TE
O
FF
IC
E
Ev an s S tr ee t Gr ee nv ill e, N C
Te l 2
.7
.3
N C
Ar ch ite ct ur al
L ic en se
N o.
N
C In te rio r D es ig n
Li ce ns e
N o.
N
C En gi ne er in g Li ce ns e N o.
C
-0
N
C La nd sc ap e
Ar ch ite ct ur al
L ic en se
N o.
C -4 ea st gr ou p.
co m
SC
O
ID
-3
-0 1A
SC
O
C O
M M
EN
T
R
ES
U
BM
IT
TA
L
/2 2/
AH
IS
SU
E
FO
R B
ID
/1 9/
AH
PH
AS
E
ER
O
SI
O
N C
O N
TR
O
L
PL
AN
C101
/0
6/
AF BR
N
SCALE 1"=40'
40'0'40' 20'
C101
PHASE 2 EROSION CONTROL PLAN
SCALE: 1" = 40'
EXISTING ASHPALT DEMOLITION
EXISTING CURB & GUTTER DEMOLITION
EXISTING CONCRETE DEMOLITION
RECLAIM EXISTING BRICKS
EXISTING BUILDING DEMOLITION, SEE ARCH PLANS
EXISTING TREE DEMOLITION
EXISTING SITE FEATURE DEMOLITION
SILT FENCE
SITE DEMOLITION LEGEND
GENERAL NOTES
1. GENERAL CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL UTILITY
SERVICES, DRAINAGE, ETC., TO THIS AREA OR ADJACENT AREAS DURING
DEMOLITION AND CONSTRUCTION.
2. ALL DEBRIS FROM DEMOLITION ACTIVITIES SHALL BE REMOVED FROM THE
SITE AND DISPOSED OF PROPERLY IN ACCORDANCE WITH ALL AGENCIES
HAVING JURISDICTION.
T h is d o c u m e n t, t o g e th e r w it h t h e c o n c e p ts a n d d e s ig n s p re s e n te d h e re in a s a n i n s tr u m e n t o f s e rv ic e is i n te n d e d o n ly f o r th e s p e c if ic p u rp o s e a n d c lie n t fo r w h ic h i t w a s p re p a re d
R e u s e o f a n d i m p ro p e r re lia n c e o n t h is d o c u m e n t w it h o u t w ri tt e n a u th o ri z a ti o n a n d a d a p ta ti o n b y K im le y -H o rn a n d A s s o c ia te s
In c s h a ll b e w it h o u t lia b ili ty t o K im le y -H o rn a n d A s s o c ia te s
In c
SHEET NUMBER
KI
M
LE
Y-
H O
R N
A N
D A
SS
O
C
IA
TE
S, IN
C
Know what's below.
before you dig.Call
R
SURVEY NOTE:
EXISTING TOPOGRAPHICAL INFORMATION IS BASED ON A
BOUNDARY AND TOPOGRAPHIC SURVEY OBTAINED ON 11/14/2025.
CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL
EXISTING INFORMATION, DEPICTED OR NOT, PRIOR TO
CONSTRUCTION AND REPORT POTENTIAL CONFLICTS TO OWNER
AND ENGINEER.
GEOTECH NOTE:
GEOTECHNICAL BORING INFORMATION WAS PROVIDED WITHIN A
PRELIMINARY GEOTECHNICAL ENGINEERING REPORT PREPARED
BY TERRACON, 252-353-1600, DATED 11/20/2025.
#F -0
W W
W .K
IM
LE
Y- H
O R
N .C
O M
P H
O N
E:
-6
-2
FA
X:
-6
-2
FA
YE
TT
EV
IL
LE
S
TR
EE
T, S
U
IT
E
0, R
AL
EI
G H
, N C
EC
U
N O
R
TH
R
EC
R
EA
TI
O
N C
O M
PL
EX
PR
EP
AR
ED
F O
R
C
IT
Y O
F G
R
EE
N
VI
LL
E
G R
EE
N
VI
LL
E, N
C
U S
EA
ST
D
AT
E
AS
S
H O
W N
C H
EC
KE
D B
Y
SC
AL
E
D
ES
IG
N
ED
B
Y
D R
AW
N
B Y
TE
G
P R
O J
CITY OF GREENVILLE SITE PLAN APPROVAL
DATE: ____________
APPROVED
ZONING
SURVEYOR / FLOODPLAIN
FIRE / RESCUE
GUC WATER / SEWER
NCDOT
TRAFFIC SERVICES
*SITE PLAN APPROVAL ONLY. ENGINEER / ARCHITECT / SURVEYOR SHALL BE RESPONSIBLE FOR ADEQUACY OF DESIGN, ERRORS OR OMISSIONS IN THE PLANS. ALL PLANS SHALL MEET ALL SPECIFICATIONS, STANDARDS AND
APPLICABLE REGULATIONS.
APPROVED AS NOTED __________________
ENGINEERING
INSPECTIONS
GUC ELECTRIC
GUC GAS
VEGETATION
NOTES
BY
R
EV
IS
IO
N
S N o.
D
AT
E
CO
RP
O
RA
TE
O
FF
IC
E
Ev an s S tr ee t Gr ee nv ill e, N C
Te l 2
.7
.3
N C
Ar ch ite ct ur al
L ic en se
N o.
N
C In te rio r D es ig n
Li ce ns e
N o.
N
C En gi ne er in g Li ce ns e N o.
C
-0
N
C La nd sc ap e
Ar ch ite ct ur al
L ic en se
N o.
C -4 ea st gr ou p.
co m
SC
O
ID
-3
-0 1A
SC
O
C O
M M
EN
T
R
ES
U
BM
IT
TA
L
/2 2/
AH
IS
SU
E
FO
R B
ID
/1 9/
AH
G R
O U
N D
S
TA
BI
LI
ZA
TI
O N
AN
D
M
AT
ER
IA
LS
H
AN
D
LI
N
G
C102
/0
6/
AF BR
NCG01 GROUND STABILIZATION AND MATERIALS HANDLING EFFECTIVE: 04/01/19
GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH
THE NCG01 CONSTRUCTION GENERAL PERMIT
Implementing the details and specifications on this plan sheet will result in the construction activity being considered compliant with the Ground Stabilization and Materials Handling sections of the NCG01 Construction General Permit (Sections E and F, respectively). The permittee shall comply with the Erosion and Sediment Control plan approved by the delegated authority having jurisdiction. All details and specifications shown on this sheet may not apply depending on site conditions and the delegated authority having jurisdiction.
GROUND STABILIZATION SPECIFICATION
Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of the techniques in the table below:
POLYACRYLAMIDES (PAMS) AND FLOCCULANTS
1. Select flocculants that are appropriate for the soils being exposed during construction, selecting from the NC DWR List of Approved PAMS/Flocculants.
2. Apply flocculants at or before the inlets to Erosion and Sediment Control Measures.
3. Apply flocculants at the concentrations specified in the NC DWR List of Approved
PAMS/Flocculants and in accordance with the manufacturer's instructions.
4. Provide ponding area for containment of treated Stormwater before discharging offsite.
5. Store flocculants in leak-proof containers that are kept under storm-resistant cover or surrounded by secondary containment structures.
HAZARDOUS AND TOXIC WASTE
1. Create designated hazardous waste collection areas on-site.
2. Place hazardous waste containers under cover or in secondary containment.
3. Do not store hazardous chemicals, drums or bagged materials directly on the ground.
EQUIPMENT AND VEHICLE MAINTENANCE
1. Maintain vehicles and equipment to prevent discharge of fluids.
2. Provide drip pans under any stored equipment.
3. Identify leaks and repair as soon as feasible, or remove leaking equipment from the project.
4. Collect all spent fluids, store in separate containers and properly dispose as hazardous waste (recycle when possible).
5. Remove leaking vehicles and construction equipment from service until the problem has been corrected.
6. Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products to a recycling or disposal center that handles these materials.
LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE
1. Never bury or burn waste. Place litter and debris in approved waste containers.
2. Provide a sufficient number and size of waste containers (e.g dumpster, trash receptacle) on site to contain construction and domestic wastes.
3. Locate waste containers at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available.
4. Locate waste containers on areas that do not receive substantial amounts of runoff from upland areas and does not drain directly to a storm drain, stream or wetland.
5. Cover waste containers at the end of each workday and before storm events or provide secondary containment. Repair or replace damaged waste containers.
6. Anchor all lightweight items in waste containers during times of high winds.
7. Empty waste containers as needed to prevent overflow. Clean up immediately if containers overflow.
8. Dispose waste off-site at an approved disposal facility.
9. On business days, clean up and dispose of waste in designated waste containers.
PAINT AND OTHER LIQUID WASTE
1. Do not dump paint and other liquid waste into storm drains, streams or wetlands.
2. Locate paint washouts at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available.
3. Contain liquid wastes in a controlled area.
4. Containment must be labeled, sized and placed appropriately for the needs of site.
5. Prevent the discharge of soaps, solvents, detergents and other liquid wastes from construction sites.
PORTABLE TOILETS
1. Install portable toilets on level ground, at least 50 feet away from storm drains, streams or wetlands unless there is no alternative reasonably available. If 50 foot offset is not attainable, provide relocation of portable toilet behind silt fence or place on a gravel pad and surround with sand bags.
2. Provide staking or anchoring of portable toilets during periods of high winds or in high foot traffic areas.
3. Monitor portable toilets for leaking and properly dispose of any leaked material.
Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace with properly operating unit.
HERBICIDES, PESTICIDES AND RODENTICIDES
1. Store and apply herbicides, pesticides and rodenticides in accordance with label restrictions.
2. Store herbicides, pesticides and rodenticides in their original containers with the label, which lists directions for use, ingredients and first aid steps in case of accidental poisoning.
3. Do not store herbicides, pesticides and rodenticides in areas where flooding is possible or where they may spill or leak into wells, stormwater drains, ground water or surface water. If a spill occurs, clean area immediately.
4. Do not stockpile these materials onsite.
CONCRETE WASHOUTS
1. Do not discharge concrete or cement slurry from the site.
2. Dispose of, or recycle settled, hardened concrete residue in accordance with local and state solid waste regulations and at an approved facility.
3. Manage washout from mortar mixers in accordance with the above item and in addition place the mixer and associated materials on impervious barrier and within lot perimeter silt fence.
4. Install temporary concrete washouts per local requirements, where applicable. If an alternate method or product is to be used, contact your approval authority for review and approval. If local standard details are not available, use one of the two types of temporary concrete washouts provided on this detail.
5. Do not use concrete washouts for dewatering or storing defective curb or sidewalk sections. Stormwater accumulated within the washout may not be pumped into or discharged to the storm drain system or receiving surface waters. Liquid waste must be pumped out and removed from project.
6. Locate washouts at least 50 feet from storm drain inlets and surface waters unless it can be shown that no other alternatives are reasonably available. At a minimum, install protection of storm drain inlet(s) closest to the washout which could receive spills or overflow.
7. Locate washouts in an easily accessible area, on level ground and install a stone entrance pad in front of the washout. Additional controls may be required by the approving authority.
8. Install at least one sign directing concrete trucks to the washout within the project limits. Post signage on the washout itself to identify this location.
9. Remove leavings from the washout when at approximately 75% capacity to limit overflow events. Replace the tarp, sand bags or other temporary structural components when no longer functional. When utilizing alternative or proprietary products, follow manufacturer's instructions.
10. At the completion of the concrete work, remove remaining leavings and dispose of in an approved disposal facility. Fill pit, if applicable, and stabilize any disturbance caused by removal of washout.
EARTHEN STOCKPILE MANAGEMENT
1. Show stockpile locations on plans. Locate earthen-material stockpile areas at least
50 feet away from storm drain inlets, sediment basins, perimeter sediment controls and surface waters unless it can be shown no other alternatives are reasonably available.
2. Protect stockpile with silt fence installed along toe of slope with a minimum offset of five feet from the toe of stockpile.
3. Provide stable stone access point when feasible.
4. Stabilize stockpile within the timeframes provided on this sheet and in accordance with the approved plan and any additional requirements. Soil stabilization is defined as vegetative, physical or chemical coverage techniques that will restrain accelerated erosion on disturbed soils for temporary or permanent control needs.
A
A
BELOW GRADE WASHOUT STRUCTURE
1:1
SIDE SLOPE
(TYP.)
10 MIL
PLASTIC
LINING
3' -0
M
IN
X'
M
AX
SECTION A-A
NOT TO SCALE
ABOVE GRADE WASHOUT STRUCTURE
NOT TO SCALE
PLAN
SECTION B-B
HIGH
COHESIVE &
LOW FILTRATION
SOIL BERM
8"
6"
2'
HIGH
COHESIVE &
LOW FILTRATION
SOIL BERM1:1 SIDE SLOPE
(TYP.)
10 MIL
PLASTIC LINING
B
B
3' -0
M
IN
X'
M
AX
A
SANDBAGS (TYP.)
OR STAPLES
SANDBAGS (TYP.)
OR STAPLES
SANDBAGS (TYP.)
OR STAPLES
SANDBAGS (TYP.)
OR STAPLES
NOTES:
1. ACTUAL LOCATION DETERMINED IN FIELD
2. THE CONCRETE WASHOUT STRUCTURES SHALL BE
MAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES
75% OF THE STRUCTURES CAPACITY.
3.CONCRETE WASHOUT STRUCTURE NEEDS TO BE
CLEARY MARKED WITH SIGNAGE NOTING DEVICE.
NOTES:
1. ACTUAL LOCATION DETERMINED IN FIELD
2. THE CONCRETE WASHOUT STRUCTURES
SHALL BE MAINTAINED WHEN THE LIQUID
AND/OR SOLID REACHES 75% OF THE
STRUCTURES CAPACITY TO PROVIDE
ADEQUATE HOLDING CAPACITY WITH A
MINIMUM 12 INCHES OF FREEBOARD.
3.CONCRETE WASHOUT STRUCTURE NEEDS
TO BE CLEARY MARKED WITH SIGNAGE
NOTING DEVICE.
ONSITE CONCRETE WASHOUT
STRUCTURE WITH LINER
CONCRETE
WASHOUT
CONCRETE
WASHOUT
PLAN
CLEARLY MARKED SIGNAGE
NOTING DEVICE (18"X24" MIN.)
CLEARLY MARKED SIGNAGE
NOTING DEVICE (18"X24" MIN.)
SILT FENCE
M
IN
10'
MIN
SECTION E: GROUND STABILIZATION
Required Ground Stabilization Timeframes
Note: After the permanent cessation of construction activities, any areas with temporary ground stabilization shall be converted to permanent ground stabilization as soon as practicable but in no case longer than 90 calendar days after the last land disturbing activity. Temporary ground stabilization shall be maintained in a manner to render the surface stable against accelerated erosion until permanent ground stabilization is achieved.
Site Area Description Timeframe variations
-7 days for perimeter dikes, swales, ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed unless there is zero slope
Stabilize within this many calendar days after ceasing land disturbance
None
None
(a) Perimeter dikes, swales, ditches, and perimeter slopes
(b) High Quality Water (HQW) Zones
(c) Slopes steeper than 3:1
If slopes are 10' or less in length and are not steeper than 2:1, 14 days are allowed
(d) Slopes 3:1 to 4:1
(e) Areas with slopes flatter than 4:1 14
-7 days for slopes greater than 50' in length and with slopes steeper than 4:1 -7 days for perimeter dikes, swales, ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed is d o c u m e n t, t o g e th e r w it h t h e c o n c e p ts a n d d e s ig n s p re s e n te d h e re in a s a n i n s tr u m e n t o f s e rv ic e is i n te n d e d o n ly f o r th e s p e c if ic p u rp o s e a n d c lie n t fo r w h ic h i t w a s p re p a re d
R e u s e o f a n d i m p ro p e r re lia n c e o n t h is d o c u m e n t w it h o u t w ri tt e n a u th o ri z a ti o n a n d a d a p ta ti o n b y K im le y -H o rn a n d A s s o c ia te s
In c s h a ll b e w it h o u t lia b ili ty t o K im le y -H o rn a n d A s s o c ia te s
In c
SHEET NUMBER
KI
M
LE
Y-
H O
R N
A N
D A
SS
O
C
IA
TE
S, IN
C
Know what's below.
before you dig.Call
R
SURVEY NOTE:
EXISTING TOPOGRAPHICAL INFORMATION IS BASED ON A
BOUNDARY AND TOPOGRAPHIC SURVEY OBTAINED ON 11/14/2025.
CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL
EXISTING INFORMATION, DEPICTED OR NOT, PRIOR TO
CONSTRUCTION AND REPORT POTENTIAL CONFLICTS TO OWNER
AND ENGINEER.
GEOTECH NOTE:
GEOTECHNICAL BORING INFORMATION WAS PROVIDED WITHIN A
PRELIMINARY GEOTECHNICAL ENGINEERING REPORT PREPARED
BY TERRACON, 252-353-1600, DATED 11/20/2025.
#F -0
W W
W .K
IM
LE
Y- H
O R
N .C
O M
P H
O N
E:
-6
-2
FA
X:
-6
-2
FA
YE
TT
EV
IL
LE
S
TR
EE
T, S
U
IT
E
0, R
AL
EI
G H
, N C
EC
U
N O
R
TH
R
EC
R
EA
TI
O
N C
O M
PL
EX
PR
EP
AR
ED
F O
R
C
IT
Y O
F G
R
EE
N
VI
LL
E
G R
EE
N
VI
LL
E, N
C
U S
EA
ST
D
AT
E
AS
S
H O
W N
C H
EC
KE
D B
Y
SC
AL
E
D
ES
IG
N
ED
B
Y
D R
AW
N
B Y
TE
G
P R
O J
CITY OF GREENVILLE SITE PLAN APPROVAL
DATE: ____________
APPROVED
ZONING
SURVEYOR / FLOODPLAIN
FIRE / RESCUE
GUC WATER / SEWER
NCDOT
TRAFFIC SERVICES
*SITE PLAN APPROVAL ONLY. ENGINEER / ARCHITECT / SURVEYOR SHALL BE RESPONSIBLE FOR ADEQUACY OF DESIGN, ERRORS OR OMISSIONS IN THE PLANS. ALL PLANS SHALL MEET ALL SPECIFICATIONS, STANDARDS AND
APPLICABLE REGULATIONS.
APPROVED AS NOTED __________________
ENGINEERING
INSPECTIONS
GUC ELECTRIC
GUC GAS
VEGETATION
NOTES
BY
R
EV
IS
IO
N
S N o.
D
AT
E
CO
RP
O
RA
TE
O
FF
IC
E
Ev an s S tr ee t Gr ee nv ill e, N C
Te l 2
.7
.3
N C
Ar ch ite ct ur al
L ic en se
N o.
N
C In te rio r D es ig n
Li ce ns e
N o.
N
C En gi ne er in g Li ce ns e N o.
C
-0
N
C La nd sc ap e
Ar ch ite ct ur al
L ic en se
N o.
C -4 ea st gr ou p.
co m
SC
O
ID
-3
-0 1A
SC
O
C O
M M
EN
T
R
ES
U
BM
IT
TA
L
/2 2/
AH
IS
SU
E
FO
R B
ID
/1 9/
AH
SE
LF
-IN
SP
EC
TI
O N
R
EC
O
R D
KE
EP
IN
G
A N
D R
EP
O
R
TI
N G
N O
TE
S
C103
/0
6/
AF BR
NCG01 SELF-INSPECTION, RECORDKEEPING AND REPORTING EFFECTIVE: 04/01/19
PART III
SELF-INSPECTION, RECORDKEEPING AND REPORTING
SECTION A: SELF-INSPECTION
Self-inspections are required during normal business hours in accordance with the table below. When adverse weather or site conditions would cause the safety of the inspection personnel to be in jeopardy, the inspection may be delayed until the next business day on which it is safe to perform the inspection. In addition, when a storm event of equal to or greater than 1.0 inch occurs outside of normal business hours, the self-inspection shall be performed upon the commencement of the next business day. Any time when inspections were delayed shall be noted in the Inspection Record.
NOTE: The rain inspection resets the required 7 calendar day inspection requirement.
PART III
SELF-INSPECTION, RECORDKEEPING AND REPORTING
SECTION B: RECORDKEEPING
1. E&SC Plan Documentation
The approved E&SC plan as well as any approved deviation shall be kept on the site. The approved E&SC plan must be kept up-to-date throughout the coverage under this permit.
The following items pertaining to the E&SC plan shall be kept on site and available for inspection at all times during normal business hours.
2. Additional Documentation to be Kept on Site In addition to the E&SC plan documents above, the following items shall be kept on the site and available for inspectors at all times during normal business hours, unless the Division provides a site-specific exemption based on unique site conditions that make this requirement not practical:
(a) This General Permit as well as the Certificate of Coverage, after it is received.
(b) Records of inspections made during the previous twelve months. The permittee shall record the required observations on the Inspection Record Form provided by the Division or a similar inspection form that includes all the required elements. Use of electronically-available records in lieu of the required paper copies will be allowed if shown to provide equal access and utility as the hard-copy records.
PART III
SELF-INSPECTION, RECORDKEEPING AND REPORTING
SECTION C: REPORTING
1. Occurrences that Must be Reported
Permittees shall report the following occurrences:
(a) Visible sediment deposition in a stream or wetland.
(b) Oil spills if:
· They are 25 gallons or more,
· They are less than 25 gallons but cannot be cleaned up within 24 hours,
· They cause sheen on surface waters (regardless of volume), or
· They are within 100 feet of surface waters (regardless of volume).
(c) Releases of hazardous substances in excess of reportable quantities under Section 311 of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA (Ref: 40 CFR 302.4) or G.S. 143-215.85.
(d) Anticipated bypasses and unanticipated bypasses.
(e) Noncompliance with the conditions of this permit that may endanger health or the environment.
2. Reporting Timeframes and Other Requirements After a permittee becomes aware of an occurrence that must be reported, he shall contact the appropriate Division regional office within the timeframes and in accordance with the other requirements listed below. Occurrences outside normal business hours may also be reported to the Department's Environmental Emergency Center personnel at (800) 858-0368.
3. Documentation to be Retained for Three Years All data used to complete the e-NOI and all inspection records shall be maintained for a period of three years after project completion and made available upon request. [40 CFR 122.41]
PART II, SECTION G, ITEM (4)
DRAW DOWN OF SEDIMENT BASINS FOR MAINTENANCE OR CLOSE OUT
Sediment basins and traps that receive runoff from drainage areas of one acre or more shall use outlet structures that withdraw water from the surface when these devices need to be drawn down for maintenance or close out unless this is infeasible. The circumstances in which it is not feasible to withdraw water from the surface shall be rare (for example, times with extended cold weather).
Non-surface withdrawals from sediment basins shall be allowed only when all of the following criteria have been met:
(a) The E&SC plan authority has been provided with documentation of the non-surface withdrawal and the specific time periods or conditions in which it will occur. The non-surface withdrawal shall not commence until the E&SC plan authority has approved these items,
(b) The non-surface withdrawal has been reported as an anticipated bypass in accordance with Part III, Section C, Item (2)(c) and (d) of this permit,
(c) Dewatering discharges are treated with controls to minimize discharges of pollutants from stormwater that is removed from the sediment basin. Examples of appropriate controls include properly sited, designed and maintained dewatering tanks, weir tanks, and filtration systems,
(d) Vegetated, upland areas of the sites or a properly designed stone pad is used to the extent feasible at the outlet of the dewatering treatment devices described in Item (c) above,
(e) Velocity dissipation devices such as check dams, sediment traps, and riprap are provided at the discharge points of all dewatering devices, and
(f) Sediment removed from the dewatering treatment devices described in Item (c) above is disposed of in a manner that does not cause deposition of sediment into waters of the United States.
10' MINIMUM
B B
PLAN
CONCRETE WASHOUT
SIGN DETAIL
(OR EQUIVALENT)
REQUIRED FOR ANY OPTION
36"
36"
ABOVE GRADE WITH STRAW BALES
CONCRETE
WASHOUT
' M
IN
IM
UM
10' MINIMUM
AA 3' TYP.
PLAN
SECTION A-A
BELOW GRADE WASHOUT STRUCTURE
NOTES:
1. ACTUAL LAYOUT TO BE DETERMINED IN THE FIELD BUT NOT WITHIN 50FT
OF A PROPOSED/ EXISTING CATCH BASIN AND/ OR INLETS, TOP OF
BANK OF PERENNIAL STREAM, SURFACE WATER BODY, OR WETLAND.
2. A CONCRETE WASHOUT SIGN SHALL BE INSTALLED IN CLOSE PROXIMITY
OF THE AREA AND SHALL BE CLEARLY VISIBLE.
3. GEOMEMBRANE BASIN LINER SHALL CONSIST OF A POLYPROPLENE OR
POLYETHYLENE 10 MIL THICK GEOMEMBRANE.
4. HOLES, DEPRESSIONS OR OTHER GROUND DISTURBANCE CAUSED BY THE
REMOVAL OF THE TEMPORARY CONCRETE WASHOUT FACILITIES SHALL BE
BACKFILLED, REPAIRED, AND STABILIZED TO PREVENT EROSION.
MAINTENANCE :
1. MAINTAIN WASHOUT STRUCTURE TO PROVIDE ADEQUATE CAPACITY PLUS
A MINIMUM OF 12 INCHES. REMOVE AND DISPOSE HARDENED CONCRETE
AND RETURN THE STRUCTURE TO A FUNCTIONAL CONDITION AFTER
REACHING 75% CAPACITY.
2. INSPECT WASHOUT STRUCTURE FOR DAMAGE AND MAINTAIN FOR
EFFECTIVENESS WEEKELY.
3. REMOVE CONCRETE STRUCTURE AND SIGN ON PROJECT COMPLETION,
DISPOSE CONCRETE IN APPROVED LANDFILL SITE OR RECYCLE.
4. GRADE THE EARTH MATERIAL TO MATCH EXISTING CONTOURS AND SEED
ACCORDINGLY TO PLANT SCHEDULE. MULCH AREA ACCORDINGLY.
SANDBAG
BERM
LATH AND
FLAGGING
ON 3 SIDES
10 mil PLASTIC
LINING
10 mil PLASTIC
LINING
SANDBAG
BERM
10 mil PLASTIC
LINING STRAW BALE
TYP.
PLYWOOD
48" X 24"
PAINTED WHITE
WOOD POST
3.5" X 3.5" X 8'
LAG SCREWS
BLACK LETTERS
6" HEIGHT
' M
IN
IM
UM
SECTION B-B
±24"
10 mil PLASTIC
LINING
STRAW BALE
NATIVE MATERIAL
(OPTIONAL)
WOOD OR
METAL
STAKES (2
PER BALE)
BINDER WIRE ±16"
5. PROVIDE 2" SAND LAYER TO CONCRETE WASHOUT PIT.
T h is d o c u m e n t, t o g e th e r w it h t h e c o n c e p ts a n d d e s ig n s p re s e n te d h e re in a s a n i n s tr u m e n t o f s e rv ic e is i n te n d e d o n ly f o r th e s p e c if ic p u rp o s e a n d c lie n t fo r w h ic h i t w a s p re p a re d
R e u s e o f a n d i m p ro p e r re lia n c e o n t h is d o c u m e n t w it h o u t w ri tt e n a u th o ri z a ti o n a n d a d a p ta ti o n b y K im le y -H o rn a n d A s s o c ia te s
In c s h a ll b e w it h o u t lia b ili ty t o K im le y -H o rn a n d A s s o c ia te s
In c
SHEET NUMBER
KI
M
LE
Y-
H O
R N
A N
D A
SS
O
C
IA
TE
S, IN
C
Know what's below.
before you dig.Call
R
SURVEY NOTE:
EXISTING TOPOGRAPHICAL INFORMATION IS BASED ON A
BOUNDARY AND TOPOGRAPHIC SURVEY OBTAINED ON 11/14/2025.
CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL
EXISTING INFORMATION, DEPICTED OR NOT, PRIOR TO
CONSTRUCTION AND REPORT POTENTIAL CONFLICTS TO OWNER
AND ENGINEER.
GEOTECH NOTE:
GEOTECHNICAL BORING INFORMATION WAS PROVIDED WITHIN A
PRELIMINARY GEOTECHNICAL ENGINEERING REPORT PREPARED
BY TERRACON, 252-353-1600, DATED 11/20/2025.
#F -0
W W
W .K
IM
LE
Y- H
O R
N .C
O M
P H
O N
E:
-6
-2
FA
X:
-6
-2
FA
YE
TT
EV
IL
LE
S
TR
EE
T, S
U
IT
E
0, R
AL
EI
G H
, N C
EC
U
N O
R
TH
R
EC
R
EA
TI
O
N C
O M
PL
EX
PR
EP
AR
ED
F O
R
C
IT
Y O
F G
R
EE
N
VI
LL
E
G R
EE
N
VI
LL
E, N
C
U S
EA
ST
D
AT
E
AS
S
H O
W N
C H
EC
KE
D B
Y
SC
AL
E
D
ES
IG
N
ED
B
Y
D R
AW
N
B Y
TE
G
P R
O J
CITY OF GREENVILLE SITE PLAN APPROVAL
DATE: ____________
APPROVED
ZONING
SURVEYOR / FLOODPLAIN
FIRE / RESCUE
GUC WATER / SEWER
NCDOT
TRAFFIC SERVICES
*SITE PLAN APPROVAL ONLY. ENGINEER / ARCHITECT / SURVEYOR SHALL BE RESPONSIBLE FOR ADEQUACY OF DESIGN, ERRORS OR OMISSIONS IN THE PLANS. ALL PLANS SHALL MEET ALL SPECIFICATIONS, STANDARDS AND
APPLICABLE REGULATIONS.
APPROVED AS NOTED __________________
ENGINEERING
INSPECTIONS
GUC ELECTRIC
GUC GAS
VEGETATION
NOTES
BY
R
EV
IS
IO
N
S N o.
D
AT
E
CO
RP
O
RA
TE
O
FF
IC
E
Ev an s S tr ee t Gr ee nv ill e, N C
Te l 2
.7
.3
N C
Ar ch ite ct ur al
L ic en se
N o.
N
C In te rio r D es ig n
Li ce ns e
N o.
N
C En gi ne er in g Li ce ns e N o.
C
-0
N
C La nd sc ap e
Ar ch ite ct ur al
L ic en se
N o.
C -4 ea st gr ou p.
co m
SC
O
ID
-3
-0 1A
SC
O
C O
M M
EN
T
R
ES
U
BM
IT
TA
L
/2 2/
AH
IS
SU
E
FO
R B
ID
/1 9/
AH
ER
O
SI
O
N C
O N
TR
O
L D
ET
AI
LS
C104
/0
6/
AF BR
TREE PROTECTION SIGN:
· SHALL BE ALL-WEATHER MATERIAL
· SHALL BE MINIMUM OF 11"X17"
· MULTIPLE SIGNS MAY BE REQUIRED TO
ENSURE VISIBILITY FROM ALL DIRECTIONS
OF TREE PROTECTION ZONE
DRIP LINE
TREE PROTECTION SIGN
(SEE ENLARGEMENT - THIS DETAIL)
TEMPORARY CONSTRUCTION FENCING
FIRMLY DRIVEN 5' MIN. HEIGHT METAL
AT 6'-0" O.C. EXTEND STAKES TO DRIP
LINE OR LIMIT OF PLANTING ISLAND
EXISTING GRADE
3 BURIAL OF
OVERALL POST
INSTALL 2" MULCH UPON
REMOVAL OF TREE
PROTECTION FENCING
TEMPORARY
CONSTRUCTION FENCING
TREE
STAKES
SECTION
PLAN
#57 WASHED STONE
MIN. 5' LF STEEL
T-POST (1.25 LBS/LF)
NOTE
TOP OF INLET STRUCTURE MUST BE 12" LOWER
THAN DOWN SLOPE, GROUND ELEVATION OR
INSTALL TEMPORARY DIKE BELOW STRUCTURE
TO PREVENT BYPASS FLOW.
TYP. STORM
DRAINAGE
INLET STRUCTURE
4' - 0" MAX.
19 GAUGE HARDWARE CLOTH
(14" MESH OPENING)
2:11' - 4"
INSTALL WITH FLAP OF HARDWARE
CLOTH UNDER STONE
MIN. 5 LF STEEL 'T' POST
(1.25 LBS/LF)
2' - 0" 3' - 0"
2' - 0"
NCDOT #57 WASHED STONE
(ALL FOUR SIDES)
A1 C104
SILT FENCE
SCALE: NOT TO SCALE
B4 C104
TREE PROTECTION FENCING
SCALE: NOT TO SCALE
B1 C104
CONSTRUCTION ENTRANCE
SCALE: NOT TO SCALE
C1 C104
SKIMMER DETAIL
SCALE: NOT TO SCALE
D4 C104
INLET PROTECTION (HARDWARE CLOTH & GRAVEL)
SCALE: NOT TO SCALE
TEMPORARY SEEDING
DATE
APR 15-AUG 14 GERMAN MILLET 50 LBS/ACRE
AUG 15-APR 14 RYE (GRAIN) 50 LBS/ACRE
YEAR ROUND FERTILIZER 10-20-20 400 LBS/ACRE
SEEDING AND MULCHING
MARCH 1 - AUGUST 31
75# TALL FESCUE
25# BERMUDAGRASS (HULLED)
500# FERTILIZER
4000# LIMESTONE
35# BERMUDAGRASS (HULLED)
500# FERTILIZER
75# TALL FESCUE
4000# LIMESTONE
SEPTEMBER 1 - FEBRUARY 28
WATER AND BORROW LOCATIONS
MARCH 1 - AUGUST 31
50# TALL FESCUE
10# CENTIPEDE
25# BERMUDAGRASS (HULLED)
500# FERTILIZER
4000# LIMESTONE
10# CENTIPEDE
35# BERMUDAGRASS (HULLED)
50# TALL FESCUE
500# FERTILIZER
4000# LIMESTONE
SEPTEMBER 1 - FEBRUARY 28
ALL ROADWAY AREAS
VEGETATIVE PLAN:
VEGETATIVE COVER SHALL BE IN ACCORDANCE
WITH THE SEEDING SCHEDULE AND THE
FOLLOWING SPECIFICATION SECTIONS:
SECTION 02110 SITE CLEARING
SECTION 02120 EROSION & POLLUTION CONTROL
SECTION 02228 CLEAN-UP & SEEDING
NPDES INSPECTION REQUIREMENTS:
ANALYSIS
1. SCARIFY SOIL TO A DEPTH OF THREE (3) INCHES AND WORK INTO A SATISFACTORY
SEED BED BY DISKING, USE OF CULTIPACKERS, HARROWS, DRAGS AND OTHER
APPROVED MEANS.
2. PREPARATION OUTLINED ABOVE SHALL NOT BE DONE WHEN THE SOIL IS FROZEN, WET
OR OTHERWISE IN AN UNFAVORABLE CONDITION.
3. BEGIN AND COMPLETE SEEDING OPERATIONS AS OUTLINED AS SOON AS POSSIBLE
AFTER FINAL GRADING IS COMPLETED, BUT IN NO EVENT LATER THAN 14 CALENDAR
DAYS AFTER COMPLETION OF FINAL GRADING.
4. SEEDING AND MULCHING OPERATIONS SHALL NOT BEGIN UNTIL ELECTRICAL SERVICE
HAS BEEN INSTALLED WITHIN THE PROJECT, UNLESS DIRECTED BY THE
ARCHITECT/ENGINEER.
5. DISTRIBUTE LIME AND FERTILIZER, UNIFORMLY OVER SEED BED AND HARROW, RAKE,
OR OTHERWISE WORK SAME INTO SEED BEDS.
6. DISTRIBUTE SEED UNIFORMLY OVER SEED BED. COVER SEED LIGHTLY AFTER
SEEDING.
7. NO LIME, FERTILIZER, OR SEED SHALL BE APPLIED DURING A STRONG WIND, WHEN
SOIL IS WET OR OTHERWISE UNWORKABLE. SHOULD RAIN FOLLOW SEEDING BEFORE
ROLLING IS BEGUN, THE BED SHALL NOT BE ROLLED.
SEED BED PREPERATION NOTES
MAINTENANCE PLAN
1. ALL EROSION AND SEDIMENT CONTROL PRACTICES WILL BE CHECKED FOR STABILITY
AND INTEGRITY FOLLOWING EVERY 0.5” OVER 24-HOUR PERIOD RAINFALL EVENT, BUT IN
NO CASE LESS THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS WILL BE MADE
IMMEDIATELY TO MAINTAIN ALL PRACTICES AS DESIGNED.
2. SEDIMENT WILL BE REMOVED FROM BEHIND THE SEDIMENT FENCE WHEN IT BECOMES
0.5 FT DEEP AT THE FENCE. THE SEDIMENT FENCE WILL BE REPAIRED AS NECESSARY
TO MAINTAIN A BARRIER.
3. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE/ EXIT WILL BE INSPECTED
PERIODICALLY. WHEN MUD BEGINS TO BUILD-UP, THE ENTRANCE WILL BE BLADED OFF
REMOVING THE MUD. ADD NEW STONE TO ENTRANCE AS NEEDED.
4. SEDIMENT WILL BE REMOVED FROM INLET PROTECTION DEVICES WHEN STORAGE
CAPACITY HAS BEEN APPROXIMATELY 50% FILLED. GRAVEL WILL BE CLEANED OR
REPLACED WHEN THE SEDIMENT POOL NO LONGER DRAINS PROPERLY.
5. ALL SEEDED AREAS WILL BE FERTILIZED, RE-SEEDED AS NECESSARY AND MULCHED
ACCORDING TO SPECIFICATION IN THE VEGETATIVE PLAN TO MAINTAIN A VIGOROUS,
DENSE VEGETATIVE COVER.
EROSION NOTES:
GROUND STABILIZATION
SITE AREA
DESCRIPTION
* PERIMETER DIKES,
SWALES, DITCHES
AND SLOPES
* HIGH QUALITY
WATER (HQW)
ZONES
* SLOPES STEEPER
THAN 3:1
* SLOPES 3:1 OR
FLATTER
* ALL OTHER AREAS
WITH SLOPES
FLATTER THAN 4:1
STABILIZATION
TIME FRAME
7 DAYS
7 DAYS
7 DAYS
14 DAYS
14 DAYS
STABILIZATION TIME
FRAME EXCEPTIONS
NONE
NONE
IF SLOPES ARE 10' OR
LESS IN LENGTH AND ARE
NOT STEEPER THAN 2:1,
14 DAYS ARE ALLOWED.
7 DAYS FOR SLOPES
GREATER THAN 50 FEET
IN LENGTH
NONE (EXCEPT FOR
PERIMETERS AND
HQW ZONES)
CONSTRUCTION SEQUENCE
1. OBTAIN AND POST A COPY OF THE CERTIFICATE OF EROSION AND SEDIMENT CONTROL PLAN APPROVAL. NOTIFY THE NC DEQ, WILMINGTON REGIONAL OFFICE AT (910) 796-7326 PRIOR TO COMMENCING CONSTRUCTION. A PRECONSTRUCTION MEETING MAY BE REQUIRED AT THE DISCRETION OF NCDEQ.
2. DISTURB LAND ONLY AS NECESSARY TO INSTALL TEMPORARY EROSION AND SEDIMENT CONTROL DEVICES. INSTALL ADDITIONAL EROSION AND SEDIMENT CONTROL DEVICES AS NEEDED OR AS
DIRECTED BY THE ENGINEER AND AS SHOWN ON THE PLANS.
3. PERFORM SITE CLEARING AND DEMOLITION, IN ACCORDANCE WITH PLANS, INCLUDING REMOVAL OF ASPHALT, EXISTING CURB AND GUTTER, AGGREGATE BASE COURSE, SIDEWALK, TREES, SHRUBS, ETC. FROM THE SITE AND DISPOSE OF DEBRIS AT AN APPROVED SITE. PRIOR TO AND DURING DEMOLITION PHASE INSTALL APPROPRIATE EROSION AND SEDIMENTATION CONTROL
MEASURES.
4. CONSTRUCT TEMPORARY GRAVEL CONSTRUCTION ENTRANCE AND BRING IN FILL MATERIAL TO SURCHARGE BUILDING SITE AND PROVIDE APPROPRIATE EROSION CONTROL MEASURES.
5. TRANSITION EROSION CONTROL MEASURES FROM DEMOLITION PHASE TO CONSTRUCTION PHASE AND INSTALL MEASURES IN APPROPRIATE AREAS.
6. BEGIN CONSTRUCTION OF THE BUILDING PAD, GRADING OF THE SITE, UTILITY SERVICE INSTALLATION AND STORM DRAINAGE STRUCTURES AND PIPING.
7. MAINTAIN EROSION AND SEDIMENTATION MEASURES DURING CONSTRUCTION. CHECK THE MEASURES FOR FAILURE AND AVAILABLE SEDIMENT STORAGE AFTER EACH SIGNIFICANT RAINFALL
EVENT.
8. COMPLETE CONSTRUCTION OF BUILDING AND SITE IMPROVEMENTS, INCLUDING THE PLACEMENT OF THE AGGREGATE BASE COURSE, NEW PAVEMENT, CURB AND GUTTER, SIDEWALKS AND
UTILITY PADS.
9. MULCH AND SEED ALL DISTURBED AREAS. ANY SLOPES LEFT EXPOSED WILL WITHIN 14 CALENDAR DAYS OF COMPLETION OF ANY PHASE OF GRADING, BE PLANTED OR OTHERWISE PROVIDED WITH TEMPORARY OR PERMANENT GROUND COVER, DEVICES, OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION..
10. REMOVE ALL TEMPORARY EROSION CONTROL MEASURES ONCE PERMANENT VEGETATION IS ESTABLISHED.
11. TIME OF EXPOSURE IS APPROXIMATELY 24 MONTHS OR UNTIL COMPLETION AND STABILIZATION OF THE SITE. CONTRACTOR SHALL PREPARE FOR MAINTENANCE OF THE SITE EROSION AND
SEDIMENTATION MEASURES APPROPRIATE FOR THE EXPECTED DURATION.
1. MUST KEEP A RAIN GAUGE ON THE PROJECT SITE.
2. DEDICATED DEMOLITION AND OTHER WASTE AREAS AND EARTHEN MATERIAL STOCKPILES
MUST BE LOCATED AT LEAST 50' FORM STORM DRAINS OR STREAMS UNLESS NO ALTERNATIVE
IS FEASIBLE.
3. MUST INSPECT ALL EROSION AND SEDIMENT CONTROL MEASURES AT LEAST ONCE A WEEK
AND WITHIN 24 HOURS AFTER ANY STORM EVENT GREATER THAN A HALF-INCH (DURING A 24
HOUR PERIOD).
4. MUST TAKE IMMEDIATE CORRECTIVE ACTION FOR ANY DEVICE FAILURE.
5. MUST INSPECT ALL OUTLETS WHERE STORMWATER RUNOFF LEAVES THE SITE AND EVALUATE
THE EFFECT ON NEARBY STREAMS OR WETLANDS.
6. CORRECTIVE ACTION MUST BE TAKEN IF SEDIMENT IS DEPOSITED OFF-SITE OR INTO A
STREAM OR WETLAND, OR CAUSES A VISIBLE INCREASE IN TURBIDITY OF ANY WATERBODY.
7. MUST KEEP RECORDS OF THESE INSPECTIONS AND ANY CORRECTIVE ACTIONS TAKEN.
1. NO LAND DISTURBING ACTIVITY BEYOND THAT REQUIRED TO INSTALL APPROPRIATE
EROSION CONTROL MEASURES MAY PROCEED UNTIL EROSION CONTROL MEASURES ARE
INSPECTED.
2. SEED AND MULCHING OR OTHERWISE PROVIDE GROUND COVER DEVICES OR STRUCTURES
SUFFICIENT TO RESTRAIN EROSION FOR ALL EXPOSED SLOPES WITHIN 14 WORKING DAYS
OF COMPLETING ANY PHASE OF GRADING. CONTRACTOR SHALL INSPECT AND MAINTAIN AS
NEEDED ALL EROSION CONTROL DEVICES ON A WEEKLY BASIS AND AFTER EACH 0.5" OVER
24-HOUR PERIOD RAINFALL EVENT.
3. FAILURE TO KEEP EROSION CONTROL DEVICES IN GOOD WORKING ORDER MAY RESULT IN
ISSUANCE OF A STOP WORK ORDER OR CIVIL PENALTIES UP TO $5,000 PER DAY OF
VIOLATION. STIES UTILIZING SEDIMENT TRAPS MUST ALSO SPECIFY A MAXIMUM DEPTH OF
SEDIMENT PRIOR TO CLEAN OUT.
4. ALL DEWATERING OPERATIONS SHALL BE FILTERED PRIOR TO LEAVING THE SITE.
NOTE: 50# OF BAHIAGRASS MAY BE SUBSTITUTED FOR EITHER CENTIPEDE OR BERMUDAGRASS
ONLY UPON ENGINEER'S REQUEST.
A3 C104
EROSION CONTROL NOTES
SCALE: NOT TO SCALE
C4 C104
CONCRETE WASHOUT DETAIL
SCALE: NOT TO SCALE
4' MAX.
VARIABLE
DEPTH
SECURE BOTTOM OF BAFFLE TO
GROUND WITH 12" STAPLES AT
12" MAXIMUM SPACING
BAFFLE
MATERIAL
9 GAUGE MIN. HIGH
TENSION WIRE STRAND
SHALL BE SECURED TO
POST TO SUPPORT
BAFFLE MATERIAL
DRAPE BAFFLE MATERIAL
OVER WIRE STRAND AND
SECURE WITH PLASTIC TIES
AT POSTS AND ON WIRE
EVERY 12"
3'
MIN.
BAFFLE MATERIAL SHOULD BE SECURED TO THE BOTTOM
AND SIDES OF BASIN USING 12" LANDSCAPE STAPLES
11 GAUGE
LANDSCAPING
STAPLE
BAFFLE
MATERIAL
STEEL POST 2'-0" DEPTH
NOTES:
1. Use matting made of 100% coconut fiber(coir) twine woven into high strength matrix.
2. Staples should be made of 0.125 inch diameter, new steel wire formed into a ‘U’ shape not less than 12 inches in length with a throat of 1 inch in width. The staples anchor the porous baffles into the sides and bottom of the basin.
3. Grade the basin so that the bottom is level front to back and side to side.
4. Install the coir fiber baffles immediately upon excavation of the basins.
5. Install posts across the width of the sediment trap.
6. Steel posts should be driven to a depth of 24 inches and spaced in a maximum of 4 feet apart. The top of the fabric should be a minimum of 6 inches higher than the invert of the spillway. Tops of the baffles should be a minimum of 2 inches lower than the top of the earthen embankment.
7. Install 3 coir fiber baffles in basins at drainage outlets with a spacing of 1/4 the basin length. 2 coir fiber baffles can be installed in the basins less than 20 feet in length with a spacing of 1/3 the basin length.
8. Attach a 9-gauge high tension wire strand to the steel posts at a height of 6 inches above the spillway elevation with plastic ties or wire fasteners to prevent sagging. If the temporary sediment basin will be converted to a permanent stormwater basin of a greater depth, the baffle height should be based on the pool depth during use as a temporary sediment basin.
MAINTENANCE:
1. Inspect all measures at least weekly and after each rainfall of 1.0 inch or greater and repair immediately.
2. Maintain access to baffles. If the fabric collapses, tears, decomposes, or becomes ineffective, replace immediately.
3. Remove sediment deposits when it reaches half full. Replace if baffle fabric is damaged during clean-out operations. Sediment depth should never exceed half the designed storage depth.
STEEL POST
EXTEND 9 GAUGE WIRE TO BASIN SIDE OR INSTALL
T-POST TO ANCHOR BAFFLE TO SIDE OF BASIN AND
SECURE TO VERTICAL POST.
DATE: PAGE:
NORTH CAROLINA
Department of Environmental Quality
Effective Date: 9/1/2023 In accordance with the 2013 Design Manual Updates
POROUS BAFFLES
T
T
T e e d b d d
PARABOLIC CHANNEL CROSS SECTION
TRIANGULAR "V" CHANNEL CROSS SECTION
TRAPEZOIDAL CHANNEL CROSS SECTION
X-Section Area (A) = Zd2
Top Width (T) = 2dz Z= ed
X-Section Area (A) = 23 Td Top Width (T) = 1.5 A d
Z= ed
X-Section Area (A) = bd + Zd2
Top Width (T) = b + 2dz
NOTES:
1. At a minimum, grass-lined channels should carry peak runoff from the 10-year storm without eroding. Increase the capacity according to the potential damage if flood hazard exists.
2. If design velocity of the channel to be vegetated by seeding exceeds 2 feet per second, a temporary channel liner is required.
3. Channel side slopes should be 3:1 or flatter to aid in the establishment of vegetation and for maintenance. V-shaped channels along roadways should have side slopes of 6:1 or flatter for safety.
4. Remove all trees, brush, stumps,…