25-015 Pellston Public Schools Roof Plan Sealed 250409.pdf
PDF 2 MB Posted
- Solicitation number
- RFP-PELL-250000002090-3
- Issued by
- Emmet County, Michigan
About this file
This document is a roof renovation plan for Pellston Public Schools located at 172 Park St, Pellston, MI 49769, prepared by Sedgewick Architects. The project involves comprehensive roof replacements for the Elementary and Middle/High School buildings, with approximately 56,815 total square feet of roofing areas to be renovated. The roof renovation includes installing new PVC roof systems with varying slope ratios (3/12 and 4/12), new shingle roof systems, and strategic placement of ice and water membranes at eaves, valleys, and rake edges. The plan also specifies additional improvements such as new siding, approximately 1,400 square feet of pre-finished 24 GA metal siding, and metal corner trim over brick surfaces.
The project is specifically detailed on architectural sheet A2.3, dated 04/01/2025, with a project number of 25-015. The roof plan encompasses multiple areas with different square footages: Area 1 (9,555 SF), Area 2 (16,350 SF), Area 3 (14,885 SF), Area 4 (6,270 SF), and Area 5 (16,020 SF). The drawings include both satellite imagery and detailed roof plans for the Elementary and Middle/High School buildings, with precise measurements and annotations. The plan indicates that all dimensions and square footages are approximate and should be verified on-site during implementation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPROX. 56,815 TOTAL SF * ALL DIMENSIONS, SQUARE FOOTAGES, AND
ROOF SLOPES APPROXIMATE; VERIFY IN FIELD
NEW PVC ROOF SYSTEM
'-7
'-3
99'-2"
101'-3"
10560 SF
3/12
4165 SF
4/12
24370 SF
4/12
17720 SF
4/12
NEW SHINGLE ROOF SYSTEM
NEW SHINGLE ROOF SYSTEM
NEW SHINGLE
ROOF SYSTEM
GENERAL NOTES FOR ELEMENTARY
9' ROW OF ICE AND WATER
MEMBRANE AT ALL EAVES
9' ROW OF ICE AND WATER
MEMBRANE AT ALL VALLEYS
3' ROW OF ICE AND WATER
MEMBRANE AT ALL RAKE EDGES
84'-2"
547'-6"
173'-8" 126'-2"
'-4
'-4
NIC
AREA 1
9555 SF
AREA 2
16350 SF
AREA 3
14885 SF
AREA 4
6270 SF
AREA 5
16020 SF
2090 SF 250 SF
130 SF
N E
W S
ID
IN
G
APPROX. 65,550 TOTAL SF * ALL DIMENSIONS AND SQUARE
FOOTAGES APPROXIMATE; VERIFY
IN FIELD
ADD METAL CORNER TRIM OVER BRICK - SEE DETAIL
NEW PRE FINISHED 24 GA METAL SIDING 1,400 SQ FT ONE
WALL AT 116' X 12' ON METAL FURRING FLASH TO ROOF OVER
BRICK STANDARD COLOR TO BE PICKED BY OWNER
SCALE
DATE
PROJECT NUMBER
S E
D G
E W
IC
K
A
R C
H
IT
E C
T S
SHEET NUMBER
A R
C H
IT
E
C T
SEAL OF ARCHITECT
E a s t C o u rt
S tr e e t F lin t, M I
-2
-9 w w w
.s fa rc h .u s
G o o d c lie n ts
G re a t a rc h it e c tu re
R E V I S I O N S
DRAWN BY:
CHECKED BY:
G o o d d e s ig n
F
E R
W E
D A
P ro je c t
D ra w in g
1/32" = 1'-0"
/9
/2
:4 :5
A
M
A2.3
04/01/2025
25-015
TAG
JSF
R o o f
P la n
P el ls to n S ch o o ls
R o o f
R en o va ti o n s
P ar k S t, P el ls to n
, M I 4
Date Description
1/32" = 1'-0"A2.3
Elementary School Roof Plan1
1/32" = 1'-0"A2.3
Middle/High School Roof Plan21 1/2"
3"
130 LN FT
SILL FINISHING CORNER TRIM
12"
12"
100 LN FT
CUSTOM J PANEL
6"
2'
3"
100 LN FT
SIG 200 FINISH
4/9/2025
| Sheets |
| A2.3 - Roof Plan |
File details come from the government source that posted it. Updated .