25-00912 CDIS Morgridge Foodservice Equipment Amendment 1.pdf

PDF 48 KB Posted

Attached to
Foodservice Equipment (2025-UWMSN-00912-RFB)
Solicitation number
2025-UWMSN-00912-RFB
Issued by
Dane County, Madison City, Wisconsin

About this file

This is Amendment 1 to RFB 2025-UWMSN-00912-RFB for Foodservice Equipment for the University of Wisconsin-Madison. The amendment provides clarification on equipment specifications, including details for a Nemco Warmer (2 compartment with 4 insets, 4 hinged lids, and 4 5oz ladles), confirmation that the MerryChef e4 can be replaced with model e4s, specifications for items #12 and #13 to be installed in owner-provided counters with cutouts, and details for a dishmachine requiring a drain water tempering kit and 208-240v/60Hz/3ph power. The amendment also confirms specifications for a Manitowoc Ice Machine requiring 120V, 5.5A, 60Hertz Air cooled 6 AMPS power supply.

The amendment is presented in a question-and-answer format addressing eight specific technical queries from potential bidders. The document references an attached drawing that was not included in the provided file. The amendment serves to clarify technical specifications that will impact pricing and installation requirements for the specified equipment.

View the file

Other files

File Type Posted
0215-2121-02-CD-A448_cafe layout.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2025-UWMSN-00912-RFB Amendment 1

Q.1. Item #1, Nemco Warmer, how many insets, tops and ladles total?

A.1. Warmer should be 2 compartment and provide 4 insets and 4 tops 4 ladles.

Q.2. Item #1, Nemco Warmer, For the tops – do you want a lift-off or hinged lid?

A.2. hinged lid

Q.3. Item #1, Nemco Warmer, What size ladle?

A.3. 5oz

Q.4. Item #3 – MerryChef #e4 has been replaced by #e4s – please confirm this is ok.

A.4. ok

Q.5. Item #12 & 13 – are these going into an Owner provided counter?

A.5. Yes, owner provided counter with cut outs

Q.6. Item #14 – dishmachine: please confirm if tabling is needed? What is the drain material – is a drain water tempering kit needed? Please confirm voltage needed.

A.6. No tabling, Yes, drain watering tempering kit needed, 208-240v/ 60Hz/3ph

Q.7. Is there a drawing available for this project?

A.7. See attached

Q.8. Item #6, Manitowoc Ice, Machine; please verify if you want 115/60/1 Air Cooled 6 amps or 208-230/60/1 Air Cooled 3 amps

A.8. 120V, 5.5A, 60Hertz Air cooled 6 AMPS

File details come from the government source that posted it. Updated .