This document provides the salient characteristics for a Trane Tower Tech cooling tower required to replace the existing system at Facility 431 on Patrick Space Force Base. The cooling tower is needed to maintain air conditioning operations for the 45th SW Theater and 45th SW Chapel, as the current system has reached the end of its service life due to a corrosive environment. The replacement cooling tower must be capable of providing 465 GPM of cooling capacity, operate on 208/3 VAC, and be CTI certified with non-corrosive FRP construction and stainless steel hardware. Optional features include a NEMA-3R motor protection panel, manufacturer startup and owner training, and a 6-foot substructure kit. The document is in support of Solicitation FA252124QB051 for the Patrick Space Force Base Cooling Tower replacement, which requires submitting quotes in PDF or Word format with no installation needed.

View the file

Other files

File Type Posted
24QB051 - Clause Set.pdf PDF
24QB051 - Combined Synopsis Solicitation.pdf PDF
24QB051 J and A Final.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TRANE TOWER TECH COOLING TOWER REPLACEMENT FOR

FACILITY 431

Abstract Salient Characteristics for Trane Tower Tech Cooling Tower

NEED/ REQUEST FOR COOLING TOWER AT FACILITY 431.

The request for a Tower Tech cooling tower is required to maintain air conditioning operations for the 45th SW Theater and 45th SW Chapel. The cooling tower are both essential part of the chiller system that provides necessary equipment and comfort cooling to the facility. The current system has reached its manufacture end of life usage due to corrosive environment. All equipment and space in the facility must have and maintain a 65°F-70°F +/- 2°F degree condition space as well as a 20-30% relative humidity.

COMMODITY REPLACEMENT

• Cooling Tower: A specialized heat exchanger in which air and water are brought into direct contact with each other in order to reduce the water's temperature. As this occurs, a small volume of water is evaporated, reducing the temperature of the water being circulated through the tower.

SALIENT CHARACTRERISTIC

Tower tech Cooling Tower

• 465 GPM

• 208/3 VAC/PH

• CTI Certified Factory Assembled Cooling Module

60 Hz, -inverter ready motors

• 100% non-corrosive FRP- all stainless steel hardware

• Basin corner inspection ports (4) per module

• PE stamped for 200mph hurricane wind-loads

Optional Features:

• Unit mounted NEMA-3R motor protection panel for single point connection

• Manufacture assisted start-up

• Factory Startup and Owner Training

Field Installed Accessories:

• 6’ sub structure kit

• NEMA 3R VFD with bypass (Ships loose for field installation) Warranty (starts at unit start-up or 6 months from shipment, whatever occurs first)

• 60 months parts (fill media, drift eliminators, and fan motors)

• 15 year structural warranty

• 12 months labor