Text version
Pawnee OEH&E Office Water Service Line
Bid Sheet
MODIFIED 8/29/2022
SR#4281
Item Amount Unit Price/Unit Price
Furnish & Install 1" DR 11 HDPE Water Service Line 1300 LF #12 Tracer wire 1300 LF Creek Bore with 4" HDPE Casing 30 LF
OPTIONS: Electric Cable from New House to Pump House UF 8 gauge 3 Conductors (Direct Burial) OR 1300 LF 6 gauge AWG Aluminum Cable 3 Conductors (Direct Burial) 1300 LF
UF 14 gauge cable 2 Conductors – Pressure Switch to Pump House (Direct Burial) 1300 LF 40 Amp Breaker at house 1 EA 40 Amp Breaker Box with Main Disconnect 8-12 circuits at Pump House 1 EA
a. Two pole (230V) 20 Amp Breaker for Pump
b. Breaker for convenience Outlet 15A 115V at Pump House
c. Overhead Light with switch by door
d. Two Pole (230V) 30 Amp Breaker for Heater (w/thermostat) 12 gauge cable (230V) from Pump House Breaker Box to Pump Control Box and from Pump Control Box to Pump Motor 12 LF Pump Control Box 1 EA
a. Contactor rated 230V/20 Amp or greater
b. Provision for termination of incoming conductors including control from pressure switch Furnish & Install Booster Pump 1 EA
a. 1/2 hp, 115/230V @ 60 Hz, 8 stages, single phase
b. Pressure 120 psi max
c. Max case pressure 300 psi
d. Connection inlet & outlets 3/4" NPT(F)
e. Flow 5.7 GPM at 60 psi
f. Check valve, pressure gauge, pressure relief valve Furnish & Install Insulated Steel 4' X 4' X 4' Pump House for Booster Pump and Appurtenances 1 EA Furnish & Install 62 gallon pressure tank to be located at new house 1 EA
a. Furnish & Install Pressure switch at pressure tank at house
b. Furnish & install pressure relief valve
Furnish & Install Shut off valve and box 2 EA Imported Bedding 20 CY Rock Excavation 100 CY
TOTAL=
File details come from the government source that posted it. Updated .