About this file
This document is a federal government solicitation for an AV system upgrade to Courtroom 8.400 in the U.S. District Court for the District of Utah. The solicitation seeks a firm fixed price bid for the AV work, with delivery desired within 10 days after receipt of offer. The project involves upgrading the audio, video, and control systems in the courtroom, including new microphones, monitors, speakers, connection panels, and related equipment. Vendors must detail how any non-brand offerings meet the specified brand requirements. The period of performance will be 12 months from the date of award. The solicitation is being issued by the Administrative Office of the U.S. Courts.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SaltLakeCity CR8.4 ScheduleB.xls | XLS spreadsheet | |
| SO1-24-0001 SIGNED.pdf | ||
| 27 41 16.01 General Technology Systems Requirements.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UNITED
STATES
COURT
BPA CALL NUMBER
Audio & Video Systems Final Design Report
24-SP5-116
August 6, 2024 District of Utah
Salt Lake City, Utah
Salt Lake City Courtroom 8.400
DISTRICT
T001 AV SYMBOL SCHEDULE
T002 AV SYMBOL SCHEDULE
T003 AV CABLE SCHEDULE / AV SIGNAL TYPE ABBREVIATIONS SCHEDULE
T004 AV CABLE INSTALLATION REQUIREMENTS SCHEDULE
T005 MICROPHONE, MONITOR & MOUNT, DESK SPEAKER INSTALLTION REQUIREMENTS
SCHEDULES
T006 MATRIX MIXER ROUTING SCHEDULE
T007 GENERAL PROJECT NOTES
T008 GENERAL PROJECT NOTES
T009 GENERAL PROJECT NOTES
T010 SHEET KEYNOTES FOR ALL AV PLAN SHEETS
T101 AV SYSTEMS FLOOR PLAN
T201 AV SYSTEMS CEILING PLAN
T501 JUDGE'S BENCH CONCEPTUAL INSTALLATION DETAIL
T502 MONITOR - LOW PROFILE DESK MOUNT DETAIL
T503 EMITTER PANEL CONCEPTUAL INSTALLATION DETAIL
T504 INTERPRETER'S CONTROL PANEL CONCEPTUAL DETAIL
T505 CABLE CUBBY W/ POWER MODULE INSTALLATION DETAIL
T506 DESK SPEAKER REAR ELEVATION
T507 CAMERA POCKET INSTALLATION DETAIL
T508 LARGE MONITOR - ROLL ABOUT STAND MOUNT DETAIL
T509 CABLE LABEL DETAIL
T601 AUDIO SYSTEM SINGLE LINE DIAGRAM
T602 VIDEO SYSTEM SINGLE LINE DIAGRAM
T603 CONTROL SYSTEM SINGLE LINE DIAGRAM
T604 DATA OUTLET PINNING DETAIL & SPARE TIME DATA CABLE SINGLE LINE DIAGRAM
T605 COUNSEL TABLE UMBILICAL CORD DETAIL & SINGLE LINE DIAGRAM
T606 LECTERN DESK UMBILICAL CORD DETAIL & SINGLE LINE DIAGRAM
T607 GALLERY MONITOR UMBILICAL CORD DETAIL & SINGLE LINE DIAGRAM
T608 INTERPRETER'S CONTROL PANEL SINGLE LINE DIAGRAM
T701 CONNECTION PANEL DETAILS
T702 CONNECTION PANEL DETAILS
T703 CONNECTION PANEL DETAILS
T704 CONNECTION PANEL DETAILS
T705 CONNECTION PANEL DETAILS
T706 CONNECTION PANEL DETAILS
T707 CONNECTION PANEL DETAILS
T708 CONNECTION PANEL DETAILS
T709 CONNECTION PANEL DETAILS
T710 CONNECTION PANEL DETAILS
T711 CONNECTION PANEL DETAILS
T712 CONNECTION PANEL DETAILS
TABLE of CONTENTS
I. AV SYSTEMS DRAWINGS
27 41 16.01 GENERAL TECHNOLOGY SYSTEMS REQUIREMENTS
27 41 16.02 BASIC TECHNOLOGY SYSTEMS REQUIREMENTS
27 41 16.03 BASIC TECHNOLOGY SYSTEMS MATERIALS AND METHODS
27 41 16.51 AUDIO SYSTEMS
27 41 16.52 VIDEO SYSTEMS
27 41 16.53 CONTROL SYSTEMS
II. SPECIFICATIONS
I. AV SYSTEMS DRAWINGS
DIGITAL SIGNAL PROCESSORDSP
TELEPHONE SYSTEM INTERFACETSI
HEADPHONE AMPLIFIERHPA
MODULATORMOD
WM
WIRELESS MICROPHONE SYSTEM
SYMBOL DESCRIPTION
POWER RELAYPR
CONNECTION PANELCP#
TRANSIENT VOLTAGE SURGE SUPPRESSORTVSS
DOCUMENT CAMERA, , NOT USED ON THIS PROJECTDC
TOUCH PANELTP
CONTROL SYSTEM + NETWORK SWITCHCS
AV SYMBOL SCHEDULE
EMITTER PANEL W/ WALL/CEILING MOUNT BRACKETEP
ENCODER, DECODERENC
HDBT RECEIVERHRX
UNINTERRUPTIBLE POWER SUPPLYUPS
NETWORK SWITCHNS
SCALING BRIDGESB
WINDOWING PROCESSORWP
ANNOTATION PROCESSOR, NOT USED ON THIS PROJECTANN
TOUCH PANEL, SMALL, NOT USED ON THIS PROJECTTPS
DEC
CAMERA AND CAMERA RECEIVERCRX
HDMI DISTRIBUTION AMPLIFIERHDA
HDBT DISTRIBUTION AMPLIFIERTDA
UTX URX USB TRANSMITTER, USB RECEIVER
HDMI SWITCHERHS
SYSTEM MANAGER, AV OVER IPSM
SCALE:
SHEET TITLE: SHEET NO.
/6
/2
:2
:2
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
AV SYMBOL SCHEDULE T001SALT LAKE CITY, UT
COURTROOM 7.200 RENOVATION
NO SCALE
SYMBOL DESCRIPTION
AV SYMBOL SCHEDULE
MONITOR W/ MOUNT: PEDESTAL, PIVOT, ARTICULATING ARM, LOW-PROFILE DESK,
MOBILE CART
POWER AMPLIFIER: 4 CHANNEL, 2 CHANNEL
EQUIPMENT RACK: FLOOR STANDING
SPEAKER ASSEMBLY:
SPEAKER
TRANSFORMER
GRILLS
V VOLUME CONTROL
AUDIO STREAMERAS
DATA PATCH PANELDPP
MICROPHONE, BEAMFORMING ARRAY
DANTE INTERFACEDAN
CHARGING BASECB
WIRELESS ACCESS POINTWAP
DESK MICROPHONE
SHOCK MOUNTED MICROPHONE
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:2
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
AV SYMBOL SCHEDULE T002SALT LAKE CITY, UT
ABBREVIATION
AL
AV SIGNAL TYPE ABBREVIATIONS SCHEDULE
SIGNAL TYPE
AUDIO, LEFT, (LINE LEVEL)
AR AUDIO, RIGHT, (LINE LEVEL)
AA ANALOG AUDIO, (LINE LEVEL)
HDMI HIGH DEFINITION MULTIMEDIA INTERFACE-HIGH RESOLUTION DIGITAL VIDEO
TP TWISTED PAIR
IP INTERNET PROTOCOL
CABLE TYPE
M
L
S
C
P
X
AV CABLE SCHEDULE
DESCRIPTION
MICROPHONE CABLE, 22 AWG,
SHIELDED, TWISTED PAIR
W/DRAIN-PLENUM RATED
MICROPHONE CABLE, 22 AWG,
SHIELDED, TWISTED PAIR
W/DRAIN-PLENUM RATED
SPEAKER CABLE, 70 V,
16 AWG, TWISTED PAIR
PLENUM RATED
CONTROL CABLE, 24 AWG,
4 PAIR, OVERALL SHIELD
PLENUM RATED
RF CABLE, 50 OHM,
COAXIAL, RG58
ACCEPTABLE TYPES
LIBERTY 22-1P-CMP-EZ-WH7
BELDEN 82761
LIBERTY 22-1P-CMP-EZ-WH7
BELDEN 82761
LIBERTY 16-2C-TTP
WEST PENN 25225
BELDEN 88104
WEST PENN D252404
BELDEN 89907
WEST PENN 25812
SPECIAL INSTRUCTIONS
D DATA CABLE, CAT 6 LIBERTY 24-4P-L6-EN
COMM SCOPE 75N4
SIEMON 9A6P4-45-C6-R1A
WEST PENN 4246AF
DIGITAL VIDEO CABLE, 4 PAIR, 23
AWG, CAT 6A/UTP, 10G
WEST PENN 25452
WEST PENN 25452
AVIP AV OVER IP
SN SERIAL NETWORK
DAN DANTE
DP DISPLAY PORT-HIGH RESOLUTION DIGITAL VIDEO
HDBT HD BASE T
ENET ETHERNET
SCALE:
SHEET TITLE: SHEET NO.
/6
/2
:2
:2
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
AV CABLE SCHEDULE / AV SIGNAL
TYPE ABBREVIATIONS SCHEDULE T003SALT LAKE CITY, UT
CABLE TYPE
AV CABLE INSTALLATION
REQUIREMENTS SCHEDULE
ORIGIN DESTINATION SPECIAL INSTRUCTIONSQUANTITY
ER
ER
ERCP#
ER
NOTE: THE ABOVE REQUIREMENTS APPLY TO EVERY DEVICE LOCATION SHOWN ON THE FLOOR PLAN
DRAWINGS IN EACH ROOM.
ER = EQUIPMENT RACK WHICH SERVES THE COURTROOM
ER
ER
EP X OR D 1
S 1
PROVIDE CABLE RECOMMENDED BY
MANUFACTURER
S
(ALL CP'S)
RE-USE EXISTING CABLE
RE-USE EXISTING CABLE
RE-USE EXISTING CABLE
VS
RE-USE EXISTING CABLE
RE-USE EXISTING CABLE
RE-USE EXISTING CABLEER
LIGHTING
CONTROL
SYSTEM
MOTORIZED
WINDOW
COVERINGS
RE-USE EXISTING CABLEERCHAMBERS
AUDIO
SYSTEM
RE-USE EXISTING CABLEERMOTORIZED
PROJECTION
SCREEN
ER D 2 JURY BOX BEAMFORMING MIC
SCALE:
SHEET TITLE: SHEET NO.
/6
/2
:2
:2
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
AV CABLE INSTALLATION
REQUIREMENTS SCHEDULE T004SALT LAKE CITY, UT
MICROPHONECOURTROOM POSITION QTY
DESK 1
DESK 1
BOUNDARY 1
JUDGE
COURTROOM DEPUTY
REPORTER
WITNESS DESK 1
LECTERN / CART SHOCK 2
COUNSEL TABLE DESK 2
NOTE: THE ABOVE REQUIREMENTS APPLY TO EACH POSITION SHOWN ON THE FLOOR PLANS.
WIRED LAV 1
LAW CLERK 0
WIRED LAV 1
WIRELESS MIC
(ONE RECEIVER)
HAND HELD 1
BODY PACK/ LAV 1
8.400
MICROPHONE INSTALLATION REQUIREMENTS SCHEDULE
WIRED EAR WORN 0
MOUNTCOURTROOM POSITION QTY
JUDGE
COURTROOM DEPUTY
LAW CLERK
WITNESS
LECTERN / CART 1
COUNSEL TABLE
GALLERY
EXISTING LOW PROFILE DESK STAND
MONITOR
21.5"
21.5"
REPORTER 1
21.5"
EXISTING LOW PROFILE DESK STAND
21.5"
21.5"
21.5"
65"
MONITOR & MOUNT INSTALLATION REQUIREMENTS SCHEDULE
EXISTING PORTABLE STAND
121.5"
NA
MISC. WIRED HAND HELD 0
JURY BOX 7EXISTING 21.5" EXISTING ARTICULATRING ARM
COURTROOM POSITION QTY
JUDGE
COURTROOM DEPUTY
REPORTER
WITNESS 0
DESK SPEAKER INSTALLATION REQUIREMENTS SCHEDULE
NOTE: THE ABOVE REQUIREMENTS APPLY TO EACH POSITION SHOWN ON THE FLOOR PLANS.
NOTE: THE ABOVE REQUIREMENTS APPLY TO EACH POSITION SHOWN ON THE FLOOR PLANS.
WIRED EAR WORN 0
MOUNT
NO
NA
NA
RE-USE
YES
YES
YES
YES
YES
YES
YES
YES
EXISTING LOW PROFILE DESK STAND
EXISTING LOW PROFILE DESK STAND
EXISTING LOW PROFILE DESK STAND
EXISTING LOW PROFILE DESK STAND
EXISTING LOW PROFILE DESK STAND
NA
NA
NO
NO
RE-USE
NA
NA
NO
NA
8.400
8.400
WIRELESS MIC, TIP
(FOUR RECEIVERS)
BODY PACK / LAV / HEADPHONE 4NO
JURY BOX BEAMFORMING ARRAY 1NO
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:2
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT MICROPHONE, MONITOR & MOUNT,
DESK SPEAKER INSTALLTION
REQUIREMENTS SCHEDULES T005SALT LAKE CITY, UT
COURTROOM DEPUTY
VIDEO EVIDENCE
PLAINTIFF COUNSEL
DEFENDANT COUNSEL
JUDGE
WIRELESS
INTERPRETER MIC ***
X
X
XXX XX
X X X X
XX
X X
B
X X
X X
X
X
B
X
X
X X
X
B
X
B
X
X
X
X
LECTERN X X X X X
X
R E
C O
R D
C H
A N
N E
L
R E
C O
R D
C H
A N
N E
L
R E
C O
R D
C H
A N
N E
L
A S
S
IS
T E
D L
IS
T
E N
IN
G
IR
C H
N L
R E
C O
R D
C H
A N
N E
L
IN
T
E R
P R
E T
E R
H E
A D
P H
O N
E S
B E
N C
H A
R E
A S
P E
A K
E R
S
W E
L L
A R
E A
S P
E A
K E
R S
G A
L L
E R
Y A
R E
A S
P E
A K
E R
S
X
PLAYBACK X X X XX
WITNESS X
X
X
X
X
B
X
X
X
JU
R
Y R
A
IL
S P
E A
K E
R S
X
X X X X X X
X
X
X
X
B
X
X
X
F
IX
E D
V T
C X
X
X
X
X
X
B
X
X
X
H E
A D
P H
O N
E
R E
P O
R T
E R
X
X
BENCH CONF. MIC ** X
D E
S K
S P
K R
JU
D G
E
A L
L M
IC
S
R E
C O
R D
D E
S K
S P
K R
R
E P
O R
T E
R
X
X
X
X
X
X
X
X
X
X
X S
X
X
X
B
X
X
X
X
X
X
X
B
X
X
X
X
X
X
IN
P
U T
L O
C A
T
IO
N
X
NOISE GENERATOR * X
VTC
X X X XX X XX X X
X
X
X
X
X
X
X
D E
S K
S P
K R
C
R D
X
X
B
X
X
X
X
X
X
A L
T
L A
N G
U A
G E
IR
C H
N L
D E
S K
S P
E A
K E
R
W
IT
N E
S S
B X
X
X
X
X
X
X
X
X
H E
A D
P H
O N
E
JU
D
G E
X
X
X
X
X
X
X
X
B
JU
R Y
C E
IL
IN
G S
P E
A K
E R
S
X X X
S T
R E
A M
IN
G
X
X
X
X
X
X
X
X
B
X
X
M A
R S
H A
L
X
X
X
X
X
X
X
X
B
X
X
T E
L E
P H
O N
E L
IN
E
C O
N F
E R
E N
C
IN
G A
N D
T
IP
E N
G L
IS
H
X
X
X
X
X
X
X
X
X
X
B
X
X
X
X
X
X
X
X
X
X
A U
D
IO
O U
T
C R
D
X
X
X
X
X
X
X
X
X
X
X
COURTROOM MATRIX MIXER ROUTING SCHEDULE
NOTE:
VERIFY FINAL MATRIX MIX DOWN FOR RECORD OUTPUTS AND FOR SPECIFIC TIP ROUTING WITH THE COURT PRIOR
TO PROGRAMMING.
WHEN THE BENCH CONFERENCING BUTTON ON THE TOUCH PANEL ENGAGED, ROUTE THE NOISE GENERATOR OUTPUT TO THE INDICATED MATRIX OUTPUT. IN ADDITION, MUTE ALL PUBLIC ADDRESS MICROPHONES & UNMUTE THE BENCH CONFERENCE MIC INPUT. RESTORE THE ORIGINAL ROUTING & MUTING CONFIGURATION WHEN THE
BENCH CONFERENCING BUTTON ON THE TOUCH PANEL IS DIS-ENGAGED.
WHEN THE BENCH CONFERENCING BUTTON ON THE TOUCH PANEL IS NOT ENGAGED, ROUTE THE MIXER INPUTS INDICATED BY "X" AND "B" TO THE HEADPHONE OUTPUT. WHEN THE BENCH CONFERENCING BUTTON ON THE TOUCH PANEL IS ENGAGED, ROUTE THE MIXER INPUT INDICATED BY "S" TO THE HEADPHONE OUTPUT.
WHEN THE BROADCAST BUTTON ON THE INTERPRETER'S CONTROL PANEL IS NOT ENGAGED, ROUTE THE INTERPRETER HEADSET MIC INPUT TO ALL OUTPUTS INDICATED BY "X". WHEN THE BROADCAST BUTTON ON THE INTERPRETER'S CONTROL PANEL IS ENGAGED, ROUTE THE INTERPRETER HEADSET MIC TO ALL OUTPUTS
INDICATED BY "X" AND "B".
B
WELL X X X XX XX X X XX X X X X XX XX
TELEPHONE LINE 1 (CONFERENCING AND TIP ENGLISH) X X X XX XX X X XX X X X X X XX XX
TELEPHONE LINE 2 (TIP ALT. LANGUAGE)
WIRELESS MIC 1-4 (TIP)
X
T E
L E
P H
O N
E L
IN
E
T
IP
A L
T
L A
N G
U A
G E
W
IR
E L E
S S
M
IC
-4
T
IP
X
XX
SCALE:
SHEET TITLE: SHEET NO.
/6
/2
:2
:2
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
MATRIX MIXER ROUTING SCHEDULE T006SALT LAKE CITY, UT
SCALE:
SHEET TITLE: SHEET NO.
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
GENERAL PROJECT NOTES T007SALT LAKE CITY, UT
COURTROOM 7.200 RENOVATION
NO SCALE
GENERAL PROJECT NOTES
1. INSTALL ALL ELECTRONIC SYSTEMS EQUIPMENT IN COMPLIANCE WITH THE MANUFACTURERS WRITTEN INSTRUCTIONS, SEISMIC
CODES, AND INDUSTRY WIDE ACCEPTED PRACTICES. SUPPORT EQUIPMENT WEIGHT FROM BUILDING STRUCTURE. DURING THE SUBMITTAL PROCESS, PROVIDE SHOP DRAWINGS WHICH DETAIL PROPOSED MOUNTING AND FASTENERS FOR ALL SUCH
EQUIPMENT.
2. PROVIDE MANUFACTURER RECOMMENDED POWER SUPPLIES, TRANSFORMERS, AND POE INJECTORS FOR ALL SPECIFIED
EQUIPMENT.
3. PROVIDE ALL NECESSARY CABLE AND CONNECTORS TO COMPLETE MANUFACTURER RECOMMENDED CABLE TO EQUIPMENT TERMINATION TO FORM A COMPLETE AND FULLY FUNCTIONAL SYSTEM AS SHOWN. PROVIDE CONNECTORS WHICH PASS FULL
BANDWIDTH CAPABILITY OF THE SPECIFIED CABLE.
4. PROVIDE PATCH CABLES TO FULLY INTERCONNECT ALL PORTABLE EQUIPMENT WITH THE SPECIFIED CONNECTION PANELS, SYSTEM INTERFACES, AND MISCELLANEOUS EQUIPMENT. LABEL ALL PATCH CABLES FOR IDENTIFICATION OF SPECIFIC USE.
PROVIDE HDMI PATCH CORDS WITH COMPRESSION CONNECTORS.
5. PROVIDE MANUFACTURER RECOMMENDED, AND INDUSTRY STANDARD, SIGNAL LEVELS THROUGHOUT ENTIRE SYSTEM. PROVIDE ALL REQUIRED DISTRIBUTION AND PROCESSING EQUIPMENT, INCLUDING BUT NOT LIMITED TO SIGNAL DISTRIBUTION AMPLIFIERS.
6. PROVIDE RACK MOUNT KITS FOR ALL RACK MOUNTED EQUIPMENT. WHERE MANUFACTURERS DO NOT PROVIDE RACK MOUNT KITS, PROVIDE CUSTOM RACK MOUNT KITS.
7. FILL ALL UNUSED RACK SPACE WITH BLANK/VENT PANELS.
8. PROVIDE UNSWITCHED POWER TO THE CONTROL SYSTEM CENTRAL PROCESSOR AND ALL NETWORK SWITCHES.
9. IF CABLE MUST BE INSTALLED INSIDE OF AN AIR PLENUM, PROVIDE THE PLENUM RATED EQUIVALENT TO THE CABLE SPECIFIED.
10. INSTALL RF ANTENNAS OUTSIDE OF EQUIPMENT RACK. SELECT FINAL LOCATION BASED ON SYSTEM PERFORMANCE W/ON SITE CONDITIONS. LOCATE ANTENNAS IN COMPLIANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS TO PROVIDE INTERFERENCE FREE & DROP OUT FREE OPERATION, WHERE BEST PERFORMANCE IS ACHIEVED. COORDINATE LOCATION WITH
THE GOVERNMENT PRIOR TO INSTALLATION.
11. INSTALL MONITORS ON LOW PROFILE DESK STANDS IN COMPLIANCE WITH THE INSTALLATION DETAIL. DO NOT DISCARD STOCK
BASES. TURN OVER TO THE COURT.
12. VERY CAREFULLY SUPPORT THE WEIGHT OF ALL HDMI CABLES CONNECTED TO RACK MOUNTED EQUIPMENT USING LOCKIT CABLE LACING BRACKETS AND RACK MOUNTED LACING BARS. PROFESSIONALY DRESS, LACE, AND STRAIN RELIEF CABLES SO THAT NO
WEIGHT FROM INDIVIDUAL HDMI CABLES IS TRANSFERRED TO INDIVIDUAL HDMI CONNECTORS.
13 AFFIX THE SPECIFIED HDMI RECEIVER TO THE REAR OF THE GALLERY MONITORS. PROVIDE VIDEO AND CONTROL SIGNALS TO THE
MONITORS FROM THE RECEIVERS.
14 REMOVE ALL OBSOLETE AV CABLE, EQUIPMENT, AND CONNECTION PANELS. RELOCATE ALL OBSOLETE AV EQUIPMENT TO A COURT DESIGNATED ROOM INSIDE THE COURTHOUSE. LEGALLY DISCARD OF ALL OBSOLETE AV CABLE. COVER ANY AND ALL EMPTY JUNCTION BOXES PREVIOUSLY USED FOR AV CONNECTION PANELS WITH HIGH IMPACT NYLON BLANK COVER PLATES. COURT TO
SELECT COVER PLATE COLOR.
SPECIAL PROJECT NOTES
1. THE WORK OF THIS PROJECT INCLUDES THE REUSE OF THE MAJORITY OF EXISTING CABLE. REFER TO THE CABLE INSTALLATION
REQUIREMENTS SCHEDULE FOR SPECIFIC REQUIREMENTS.
2. THE WORK OF THIS PROJECT EXCLUDES THE REUSE OF ANY EXISTING CONNECTOR OR CONNECTION PANEL. WITH THE EXCEPTION OF SPEAKER CABLE, RE-TERMINATE EVERY EXISTING CABLE ON BOTH ENDS IN COMPLIANCE WITH THE
CONSTRUCTION DOCUMENTS.
3. THE WORK OF THIS PROJECT EXCLUDES THE REUSE OF ANY EXISTING CABLE LABEL. RE-LABEL BOTH ENDS OF EVERY CABLE IN
COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS.
4. THE WORK OF THIS PROJECT INCLUDES THE INSTALLATION OF A FULLY TESTED AND CERTIFIED CATEGORY 6A CABLE PLANT INCLUDING, BUT NOT LIMITED TO, PROVIDING NEW DATA PATCH PANELS, AND TERMINATING THE EXISTING DATA CABLES TO THE
SPECIFIED DATA PATCH PANELS IN FULL COMPLIANCE WITH EIA/TIA 568B STANDARDS.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
GENERAL PROJECT NOTES T008SALT LAKE CITY, UT
COURTROOM 7.200 RENOVATION
GENERAL PROJECT NOTES CONT.
15 A SUBCONTRACTOR IS DEFINED AS ANY PERSON WHO IS NOT A DIRECT EMPLOYEE OF THE BPA CONTRACTOR, WORKING A
MINIMUM OF 40 HOURS PER WEEK, 52 WEEKS A YEAR FOR THE BPA CONTRACTOR.
16 INSTALL ALL PATCH CORDS AND CONNECTING CABLES THAT ARE EXPOSED TO VIEW INSIDE NYLON LOOM EXPANDABLE SLEEVING.
THIS INCLUDES, BUT IS NOT LIMITED TO PATCH CORDS AND CONNECTING CABLES INSTALLED BETWEEN CONNECTION PANELS AND CONNECTING DEVICES SUCH AS MICROPHONES, MONITORS, DESK SPEAKERS, TOUCH PANELS, ETC.
17 PROGRAM ALL NEW AV DEVICES WITH PASSWORDS WITH A NEW (NON-FACTORY DEFAULT) PASSWORD. PROVIDE A SPREADSHEET TO THE COURT IDENTIFYING ALL PROGRAMMED PASSWORDS. WORK WITH THE COURT'S IT STAFF TO PROGRAM THE SPECIFIED
NETWORK SWITCH WITH SECURITY HARDENING.
18 WHILE ON SITE DURING THE INSTALLATION, MEET WITH THE COURT'S DESIGNATED REPRESENTATIVE(S) TO FINALIZE INSTALLATION LOCATIONS FOR INDIVIDUAL EQUIPMENT ITEMS INCLUDING, BUT NOT LIMITED TO, MICROPHONES, MONITORS AND DESK SPEAKERS.
WHERE ANY AV DEVICE IS SPECIFIED TO BE MOUNTED, DEMONSTRATE MOUNTING OPTIONS AND LOCATIONS FOR THE COURT'S
DESIGNATED REPRESENTATIVE PRIOR TO INSTALLATION.
19 IN ADDITION TO THE CABLE LABELING CONVENTION USED BY THE INSTALLER, PROVIDE A SECOND, NON-TECHNICAL LABEL ON ALL
CABLE INSIDE THE EQUIPMENT RACK. FOR EXAMPLE, JUDGE DESK MIC, JUDGE LAV MIC, ETC
20 POWER ALL TRANSMITTERS, RECEIVERS, ENCODERS AND DECODERS FROM THE AV EQUIPMENT RACK.
21 AFFIX TEMPERATURE PROBE TO INTERIOR RACK STRUCTURE IN CLEAR AND OPEN SPACE WITHIN 6" OF THE TOP OF THE RACK. DO NOT ALLOW THE TEMPERATURE PROBE TO COME INTO CONTACT WITH RACK MOUNTED EQUIPMENT.
22 AFFIX ALL ENCODERS, DECODERS, TRANSMITTERS, RECEIVERS AND OTHER SIMILAR SIGNAL TRANSMISSION DEVICES OR SIGNAL CONVERSION DEVICES INSTALLED OUTSIDE OF JUNCTION BOXES TO SURFACES USING THE MANUFACTURER RECOMMENDED MOUNTING BRACKETS, AND IN COMPLIANCE WITH THE MANUFACTURER’S INSTALLATION INSTRUCTIONS USING SCREWS, NUTS AND BOLTS. THE USE OF HOOK AND LOOP (VELCRO) STRAPS, PLASTIC OR NYLON WIRE TIES, HARDWARE STORE “L” BRACKETS, OR ANY
OTHER SIMILAR MOUNTING METHOD WILL NOT BE ACCEPTED.
23 PROVIDE A MINIMUM 10’ SERVICE LOOP FOR ALL CABLE ENTERING AV EQUIPMENT RACKS. NEATLY CRESS, COIL AND STRAIN-RELIEVE ALL SERVICE LOOPS ABOVE EQUIPMENT RACKS IN COMPLIANCE WITH THE EIA/TIA CABLE BEND
SPECIFICATIONS.
24 PROVIDE COMPLETE NETWORK SWITCH CONFIGURATION AND PROGRAMMING SERVICES, INCLUDING, BUT NOT LIMITED TO, UPDATING NETWORK SWITCHES TO THE LATEST FIRMWARE, ASSIGNING ALL IP ADDRESS SCHEMES FOR SUBNET MASK GATEWAYS, MAC ADDRESSES AND IP ADDRESSES, AND CONFIGURING ALL REQUIRED VLANS FOR AV NETWORKS INCLUDING, BUT NOT LIMITED TO: AUDIO SYSTEM DSPS, VIDEO SYSTEMS, DANTE NETWORKS AND CONTROL SYSTEMS. COORDINATE WITH THE OWNER’S IT
STAFF AND FULLY COMPLY WITH ALL OWNER STANDARDS AND REQUIREMENTS.
25 PROGRAM THE SPECIFIED CAMERAS TO SIMULTANEOUSLY OUTPUT HDMI VIDEO TO THE COURTROOM AV SYSTEM, AND IP STREAMING TO THE COURT’S NETWORK. COORDINATE CAMERA AND ACCESSORY EQUIPMENT NETWORK SETTINGS WITH THE
COURT IT DEPARTMENT.
26 REMOVE ALL TRASH FROM THE PROJECT SITE AND LEGALLY DISCARD. TRASH IS DEFINED TO INCLUDE, BUT NOT BE LIMITED TO, ANY MATERIAL TRANSPORTED TO THE PROJECT SITE UNDER THIS CONTRACT THAT WILL NOT BE A PERMANENT PART OF THE INSTALLED AV SYSTEM EQUIPMENT OR SPECIFIED PORTABLE DEVICES. THE GSA OR COURT WILL NOT PROVIDE A DUMPSTER OR
PHYSICAL SPACE ON SITE TO ACCOMMODATE A LEASED DUMPSTER.
27 PROVIDE RIGHT ANGLE AND ROTATABLE XLR CONNECTORS FOR CONNECTION OF SHOCK MOUNTED MICROPHONES INSIDE
LECTERNS.
28 DO NOT USE PLASTIC ZIP TIES FOR CABLE MANAGEMENT INSIDE EQUIPMENT RACKS OR AT ANY OTHER LOCATION. PROVIDE HOOK
AND LOOP (VELCRO) WIRE TIES ONLY.
29 THE COURT WILL FURNISH A PC LOADED WITH THEIR PREFERRED VIDEO CONFERENCING SOFTWARE (ZOOM OR TEAMS). INCLUDE COSTS IN BID PROPOSALS FOR ALL EQUIPMENT AND SERVICES REQUIRED TO INSTALL THE COURT-FURNISHED PC, AND INTEGRATE THE COURT-FURNISHED PC WITH THE SPECIFIED USB SCALING BRIDGE, USB EXTENSION SYSTEMS, AUDIO SYSTEMS AND VIDEO
SYSTEMS TO FACILITATE FULL-SERVICE VIDEO CONFERENCING.
30 UPDATE FIRMWARE ON ALL SPECIFIED DEVICES PRIOR TO INSTALLATION.
31 DISABLE “ECO MODE” ON ALL MONITORS. SET THE BRIGHTNESS FOR ALL MONITORS TO 70%.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
GENERAL PROJECT NOTES T009SALT LAKE CITY, UT
COURTROOM 7.200 RENOVATION
GENERAL PROJECT NOTES CONT.
32. CAREFULLY MANAGE, STRESS-RELIEVE AND SEGREGATE ALL AV CABLE INSTALLED INSIDE COURTROOM
FURNITURE. LEAVE AMPLE CLEAR, UNOBSTRUCTED SPACE BELOW CONNECTION PANELS WITH PULL OUT
PATCH CORDS INSTALLED FLUSH IN FURNITURE WORK SURFACES.
33. PROGRAM THE DISPLAYS OF ALL INFRARED RECEIVERS WITH THE FOLLOWING CHANNEL NAMES: “ALS” FOR THE ASSISTED LISTENING CHANNEL AND “INT” FOR THE INTERPRETER CHANNEL. REMOVE (HIDE) THE
UNUSED CHANNELS FROM THE DISPLAYS.
34. PRIOR TO EXISTING SYSTEM DEMOLITION, IDENTIFY THE CABLE THAT CONNECTS THE AUDIO SYSTEM DSP TO THE CHAMBERS AUDIO SYSTEM. PROTECT AND REUSE THIS CABLE TO CONNECT THE NEWLY SPECIFIED DSP TO THE EXISTING CHAMBERS AUDIO SYSTEM. INCLUDE ALL REQUIRED CONTROL SYSTEM PROGRAMING.
PLEASE NOTE THAT THE CHAMBERS AUDIO ROUTING SYSTEM IS REMOTELY CONTROLLED BY A SEPARATE, LOCAL CONTROL SYSTEM.
35. PRIOR TO EXISTING SYSTEM DEMOLITION, IDENTIFY THE CABLES THAT CONNECT TO THE LIGHTING CONTROL SYSTEM, MOTORIZED PROJECTION SCREEN, AND MOTORIZED WINDOW COVERINGS. PROTECT AND REUSE THESE CABLES TO CONNECT THE NEWLY SPECIFIED CONTROL SYSTEM PROCESSOR TO THESE EXISTING
SYSTEMS. INCLUDE ALL REQUIRED CONTROL SYSTEM PROGRAMMING.
36. PRIOR TO CONNECTION PANEL FABRICATION, MEASURE THE EXACT EXISTING FLOOR BOX SCREW HOLE LOCATIONS, AND FABRICATE CONNECTION PANELS WITH SCREW HOLES THAT WILL ALLOW ALL SCREW
HOLES IN EXISTING FLOOR BOXES TO BE UTILIZED.
37. PROVIDE TWO NEW "D" TYPE CABLES TO THE BEAMFORMING MICROPHONE LOCATION IN THE JURY RAIL.
INCLUDE ALL COSTS TO INSTALL THE SPECIFIED CABLE WITHOUT A DEDICATED CABLE PATHWAY.
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
SHEET KEYNOTES FOR ALL AV PLAN
SHEETS T010SALT LAKE CITY, UT
COURTROOM 7.200 RENOVATION
NO SCALE
SHEET KEYNOTES
1 REMOVE THE EXISTING CAMERA AND INSTALL THE SPECIFIED CAMERA IN ITS PLACE.
2 INSTALL THE SPECIFIED CONNECTION PANEL INSIDE THE PREVIOUSLY INSTALLED FLOOR BOX.
3 INSTALL EXTENDER FOR WITNESS TOUCH MONITOR ANNOTATION CONTROL AT WITNESS BOX. CONFIRM EXACT LOCATION WITH
THE COURT PRIOR TO INSTALLATION.
4 INSTALL THE SPECIFIED HDBT RECEIVER INSIDE THE JURY RAIL STUD SPACE AT AN EASILY ACCESSIBLE LOCATION. INSTALL THE SPECIFIED MONITOR AND ARTICULATING ARM IN THE RECESS AREA OF THE VERTICAL MILLWORK RAIL OF THE JURY BOX.
CONFIRM EXACT ARTICULATING ARM LOCATION WITH THE COURT PRIOR TO INSTALLATION, SEE DETAIL. INSTALL MOUNT TO ENSURE FULL RANGE OF MOTION WHEN MOUNT IS FULLY EXTENDED. INSTALL MONITOR ON MOUNT AND DRESS CABLES INSIDE
MONITOR ARM.
5 INSTALL THE SPECIFIED CONNECTION PANELS INSIDE THE SURFACE RACEWAY. LOCATE CONNECTION PANELS AS CLOSE TO CONNECTING DEVICE AS POSSIBLE. DRESS CABLES IN ORDER TO AVOID ANY CONFLICT WITH SEATED OPERATOR. COVER ALL
REMAINING JUNCTION BOX OPENINGS WITH BLANK PLATES.
6 INSTALL THE SPECIFIED CONNECTION PANEL FLUSH IN THE HORIZONTAL WORK SURFACE.
7 REMOVE THE EXISTING EMITTER PANEL AND INSTALL THE SPECIFIED EMITTER PANEL IN ITS PLACE. SEE DETAILS.
8 AFFIX THE SPECIFIED DIGITAL ENCODERS, DECODERS, VIDEO TRANSMITTERS, RECEIVERS, AND MISC. EQUIPMENT TO THE UNDERSIDE OF THE HORIZONTAL WORK SURFACE. CONFIRM EXACT LOCATION WITH THE COURT PRIOR TO INSTALLATION.
9 REMOVE THE PIVOTING SECTION AND BASE FROM THE EXISTING EQUIPMENT RACK AND DELIVER TO A COURT DESIGNATED LOCATION INSIDE THE COURTHOUSE. LEAVE THE WALL-MOUNTED BACK BOX IN PLACE. BOLT THE SPECIFIED FLOOR STANDING RACK FRAMES WITH CASTER BASES, TOGETHER AND LOCATE WHERE SHOWN. CAREFULLY MANAGE THE CABLE BUNDLE TO THE EQUIPMENT RACKS WITH AN ADEQUATE SERVICE LOOP TO ALLOW THE RACKS TO BE RE-POSITIONED FOR FRONT AND REAR ACCESS. OBTAIN THE COURT'S APPROVAL FOR THE CABLE BUNDLE POSITION AND LOCATION PRIOR TO FABRICATION.
10 AFFIX THE SPECIFIED MICROPHONE TO THE INTERIOR FACE OF THE JURY RAIL USING THE MANUFACTURER'S INCLUDED WALL MOUNT BRACKET. CENTER THE MICROPHONE BETWEEN MONITORS AND ABOVE THE RECESSED SPEAKER. CONFIRM THE
EXACT MOUNTING LOCATION WITH THE COURT PRIOR TO INSTALLATION.
11 REUSE THE EXISTING JURY RAIL SPEAKER. CONNECT TO THE NEWLY SPECIFIED AMPLIFIER AND MAKE FULLY FUNCTIONAL.
14 VOLUME CONTROL - ALSO SHOWN ON RCP FOR SPEAKER WIRING COORDINATION.
C P
C P
A
EP
C
P
C P
C P
C P
C P
A
C P
B
C P
A
C P
B
C P
C
P
C P
C P
C P
B
C P
E P
C P
C P
C P
A
C P
C P
B
C P
VV
J u ry
B o x
J u d g e
W it n e s s S ta ti o n
C o u rt
R e c o rd e r
S ta ti o n
L a w
C le rk S ta ti o n
C o u rt
D e p u ty
S ta ti o n
F u tu re R a m p
C o u rt
R e p o rte r M
.4
W itn e s s
A tto rn e y
.4
V e s tib u le
.4
M a g is tra te
C o u rtro o m
.4
W itn e s s
A tto rn e y
.4
C o u rt
R e p o rte r D
.4
C o rrid o r
.4
C u s to d ia n
.4
J u ry
D e lib e ra tio n
.4
S o u n d lo c k
.4
V e s tib u le
.6
E x h ib it
.4
A V
E q u ip R o o m
.4
.S
T
S ta ir 2
C P
C P
C P
B
C P
A V
E Q
U
IP
M E
N T
R
A C
K S
C O
U N
S E
L6
L E
C T
E R
N
L A
W C
L E
R K
R E
P O
R T
E R
J U
D G
E
W
IT
N E
S S
T Y
P
T Y
P
T Y
P
C O
U R
T R
O O
M
D E
P U
T Y
7 T Y
P
T Y
P
T Y
P
C O
U N
S E
L
C O
U N
S E
L
C A
R T
T
Y P
T Y
P
T Y
P
T Y
P
T Y
P
T Y
P
T Y
P
T Y
P
2 2
T
Y P
SCALE:
SHEET TITLE: SHEET NO.
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
1/8" = 1'-0"
U.S. DISTRICT COURT
AV SYSTEMS FLOOR PLAN T101SALT LAKE CITY, UT
S S S S
SS S
S
SS
S S
S S
VV
R R
R
J u ry
B o x
J u d g e
W it n e s s S ta ti o n
C o u rt
R e c o rd e r
S ta ti o n
L a w
C le rk S ta ti o n
C o u rt
D e p u ty
S ta ti o n
F u tu re R a m p
C o u rt
R e p o rte r M
.4
W itn e s s
A tto rn e y
.4
V e s tib u le
.4
M a g is tra te
C o u rtro o m
.4
W itn e s s
A tto rn e y
.4
C o u rt
R e p o rte r D
.4
C o rrid o r
.4
C u s to d ia n
.4
J u ry
D e lib e ra tio n
.4
S o u n d lo c k
.4
V e s tib u le
.6
E x h ib it
.4
A V
E q u ip R o o m
.4
.S
T
S ta ir 2
S S
S
S
S
S S
S S
S S
S S
S S
S
S S
S S
S S
S S
S
SS
S
S
S S
S
S (2
S
S
S (2
S (2
NOTE: SPEAKERS, CABLE AND
VOLUME CONTROLS ARE
SHOWN FOR REFERENCE
ONLY. REUSE ALL SPEAKERS,
CABLE AND VOLUME
CONTROLS.
S (2
S
SCALE:
SHEET TITLE: SHEET NO.
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
1/8" = 1'-0"
U.S. DISTRICT COURT
AV SYSTEMS CEILING PLAN T201SALT LAKE CITY, UT
RAISED
PLATFORM
CONDUIT
FINISHED
FLOOR
SURFACE RACEWAY
MICROPHONE INPUT
CONNECTION PANEL
SLACK
MICROPHONE
CORD
GROMMET
SCALE:
SHEET TITLE: SHEET NO.
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
JUDGE'S BENCH CONCEPTUAL
INSTALLATION DETAIL T501SALT LAKE CITY, UT
INSTALL MONITOR ON LOW PROFILE DESK STAND SO
THAT BOTTOM EDGE OF THE MONITOR IS POSITIONED
ON THE DESK TOP. CONFIRM EXACT MOUNTING POINT
WITH THE COURT PRIOR TO INSTALLATION.
HORIZONTAL
WORK
SURFACE
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
MONITOR - LOW PROFILE DESK
MOUNT DETAIL T502SALT LAKE CITY, UT
JUNCTION BOX
COVER PLATE W/ GROMMETED
PENETRATION FOR CABLE EXIT
EMITTER PANEL CABLES
EMITTER PANEL
EMITTER PANEL
MOUNTING BRACKET
WALL
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
EMITTER PANEL CONCEPTUAL
INSTALLATION DETAIL T503SALT LAKE CITY, UT
10K LINEAR
TAPER PLOT
.2
BELT CLIP
HEADSET VOLUME
MIN MAX
TOP VIEW
ENGRAVED TEXT
FILLED W/
CONTRASTING
COLOR, TYP. STEEL
ENCLOSURE
.4
MIC ON/OFF
BROADCAST
TWO POSITION
PUSH BUTTON
TYPE SWITCH,
TYP.
FRONT VIEW
BOTTOM VIEW
MULTI PIN XLR TYPE
CONNECTOR FOR
CONNECTION PANEL
2.4"
SIDE VIEW
MULTI PIN XLR TYPE
CONNECTOR FOR
HEADSET / BOOM MIC
BELT CLIP
SCALE:
SHEET TITLE: SHEET NO.
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
INTERPRETER'S CONTROL PANEL
CONCEPTUAL DETAIL T504SALT LAKE CITY, UT
M
IN
CABLE CUBBY LID,
SHOWN FOLDED
AWAY
TABLE TOP
MOUNT PASS-THRU GROMMETS,
HORIZONTAL SHIFT CONTROL MODULE,
AND POWER MODULE INSIDE CABLE
CUBBY AT A MINIMUM OF 4" BELOW TOP
OF CABLE CUBBY TO ALLOW SPACE FOR
CONNECTORS TO BE HIDDEN AWAY
WHEN LID OF CABLE CUBBY IS IN
CLOSED POSITION
CABLE CUBBY LID MUST BE ABLE TO CLOSE
COMPLETELY FLUSH WITH TABLE TOP, WITHOUT
INTERFERENCE WITH CONNECTORS.
NOTE:
MOUNT POWER MODULE
AT TOP OF CABLE CUBBY
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
CABLE CUBBY W/ POWER MODULE
INSTALLATION DETAIL T505SALT LAKE CITY, UT
POWER CORD W/ 90° CABLE
EXIT IN DIRECTION SHOWN
ROTATABLE, 3-PIN,
90° XLR CONNECTOR
(NEUTRIK NC3MRX OR EQUAL)
SPECIFIED DESK SPEAKER IN
HORIZONTAL ORIENTATION
EXPANDABLE NYLON
LOOM SLEEVING
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
DESK SPEAKER REAR ELEVATION T506SALT LAKE CITY, UT
VIDEO CAMERA
(FURNISHED AND
INSTALLED BY AV
INSTALLER)
SIGNAL CABLE
JUNCTION BOX, TYP.
CONDUIT, TYP.
SIGNAL CABLE
(FURNISHED AND
INSTALLED BY AV
INSTALLER)
SIGNAL CABLE
JUNCTION BOX
VIDEO CAMERA
(FURNISHED AND INSTALLED
BY AV INSTALLER)
COUTROOM SIDE
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
CAMERA POCKET INSTALLATION
DETAIL T507SALT LAKE CITY, UT
LARGE SCREEN
MONITOR
ROLL ABOUT STAND
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
LARGE MONITOR - ROLL ABOUT
STAND MOUNT DETAIL T508SALT LAKE CITY, UT
L
B E
L
L A
B E
L
E Q
U
IP
M E
N T
R A
C K
E N
D O
F C
A B
(I
S
ID
E
E Q
U
IP
M E
N T
R A
C K
C
O N
N E
C T
IO
N
P A
N E
L E
N D
O F
C A
B
(F
IE
L D
D E
V
IC
E
M A
C H
IN
E
P R
IN
T
E D
L A
B E
L A
S D
E S
IR
E
D B
Y T
H E
A V
I N
S T
A L L E
R T
H A
T M
A T
C H
E S
O P
P O
S
IT
E E
N D
C L E
A R
H E
A T
S H
R
IN
K T
Y P
C A
B L E
T
Y P
M A
C H
IN
E
P R
IN
T
E D
L A
B E
L
S
IR
E D
B Y
T H
E A
V I N
S T
A L L
H
A T
M A
T C
H E
S O
P P
O S
IT
E
E N
D
M A
C H
IN
E
P R
IN
T
E D
L A
B E
L T
H A
T I D
E N
T
IF
IE
S
T
N N
E C
T
IO
N P
A N
E L L
O C
A T
IO
N
A
N D
M A
T C
H
E E
N G
R A
V E
D L
A B
E L O
N T
H E
C O
N N
E C
T
IO
P
N E
L F
O R
T H
E C
O N
N E
C T
O R
T O
W H
IC
H
T
B L E
I S
T E
R M
IN
A
T E
D L O
G
IC
B
B R
E V
IA
T
IO
N
S A
R E
A C
C E
P T
A B
L E
(T
H E
L A
B
O W
N I S
A N
E X
A M
P L E
O N
L Y
A
N D
I S
N
P R
E S
E N
T A
T
IV
E O
F E
V E
R Y
C A
B L E
L A
B E
L
J D
G D
E S
K M
IC
X
X X
X X
X X
X X
X X
X X
X X
X X
X
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
CABLE LABEL DETAIL T509SALT LAKE CITY, UT
HPA
120 VAC
TVSS
(TYP)
TO
EQUIPMENT
TVSS
(TYP)
PR
(TYP)
UPS
NC
EP
EP
CP2
INTERP. HP
ALT. LANGUAGE
CP14
REC 4
REC 3
REC 2
REC 1
EQUIPMENT RACK
REPORTER
CP11JUDGE
TO EXISTING BENCH AREA
TO EXISTING WELL AREA
TO EXISTING GALLERY AREA
BENCH SPEAKERS
WELL SPEAKERS
GALLERY SPEAKERS
JDG DESK SPKR
ASSISTED LIST.
WITNESS DESK SPKR
WITNESSCP12
NOTE: FOR DRAWING CLARITY, SOME CONNECTION PANELS ARE SHOWN ON BOTH THE INPUT SIDE AND OUTPUT SIDE.
COUNSEL TABLE
JDG HP
JUDGECP16
MARSHAL
CP17 *
INSTALL ON REAR RACK RAILS*
AV STREAM
NC = NO CONNECTION
HPA
MOD
STEREO AUDIO FROM
VIDEO EVIDENCE
PRESENTATION SYSTEM
WM
REFER TO UMBILICAL CORD DETAILS FOR MORE INFORMATION**
DSP
A = AEC M = MIC L = LINE
70V
70V
70V
CP15
L
SPEAKERS, TYP
SPEAKERS, TYP
SPEAKERS, TYP
L
HPA
COUNSEL TABLE
SPARE
NC
A A
A
A
A
L
TELEPHONE LINE 1
TO
EQUIPMENT
AUDIO STREAM
CP13
REPORTER DESK SPKR
REPORTER HP
HPA
CP13REPORTER
VOIP
ALL MICS REC
A A A
LECTERN CP4A A
A
CP5WITNESS
A A A A
NC L
NC A
NC A
SPARE
SPARE
SPARE
SPARE
L
SPARE
NC
CP2
WITNESSCP5
INTERP. HP
CP8
AVB
NS
CRD DESK SPKR
COURTROOM DEPUTYCP15
TO EXISTING JURY CEILING
JURY CEILING SPEAKERS 70V
SPEAKERS, TYP
CP7
TSI
AS
REPORTER
REPORTER
TO EXISTING ATT. WIT. ROOM
SPEAKERS AND VOLUME
CONTROLS
ATT. WIT. ROOM 70V
INTERP. HP
HPA COUNSEL TABLECP2
INTERP. HP
HPA COUNSEL TABLECP2
INTERP. HP
HPA COUNSEL TABLECP2
CP2COUNSEL TABLE
A A A
CP2COUNSEL TABLE
A A A
CP2COUNSEL TABLE
A A A
A
COURTROOM
DEPUTY
COURTROOM
DEPUTY
VTC
SB
L
L
TO EXISTING JURY RAIL
SPEAKERS, TYP
JURY RAIL SPEAKERS 70V
TO CHAMBERS AUDIO
SYSTEM
CHAMBERS
NS
DAN
DAN
TELEPHONE LINE 2
VOIP
INTERP. HP
HPA COUNSEL TABLECP2
CP2COUNSEL TABLE
A A A
JURY BOX
(BEAMFORMING MIC)
CP6B
DAN
CP6A
DAN (4 IN & 1 OUT)
CB
DAN
COURTROOM DEPUTY
WAP
DAN
JUDGE
L
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
AUDIO SYSTEM SINGLE LINE DIAGRAM T601SALT LAKE CITY, UT
HDMI
HDMI
DEC
HDMI
120 VAC
TO
EQUIPMENT
TVSS
(TYP)
UPS
HDBT
EQUIPMENT RACK
3CP12 AVIP
CP6B
AVIP AVIP
CP2 AVIP
COURTROOM DEPUTY
CP10
AVIP AVIP
CP8
AVIP AVIP
NOTE: FOR DRAWING CLARITY, SOME CONNECTION PANELS ARE SHOWN ON BOTH THE INPUT SIDE AND OUTPUT SIDE.
NC = NO CONNECTION
* INSTALL ON REAR RACK RAILS ** REFER TO UMBILICAL CORD DETAILS FOR MORE INFORMATION
NS
LAW CLERK
REPORTER
WITNESS
WITNESS CRX
CRX
HDMI
CRX
HDMI
LECTERN
JUDGE
CP4A LECTERN
TO DSP
AUDIO
TO DSPAUDIO
CP2
5CP2 AVIP
COUNSEL TABLE 8
HDMI
AVIP
AVIP
COUNSEL TABLE 6CP2 AVIP
COUNSEL TABLE 7CP2 AVIP
AVIP HDMI
CP12
AVIP
WITNESS
AVIP
COUNSEL TABLE **
AVIP
AVIP
AVIP
AVIP
TDA
HRX
HDMIHDBT
JURY RAIL
HDMI
HDMI
HDMI
HDMI
HDMI
HDMI
JURY BOX
2CP7 AVIPCOURTROOM DEPUTY
1CP16 AVIPJUDGE
COUNSEL TABLE **
COUNSEL TABLE
NC
CP17 *
CP9
CP9A
GALLERY
GALLERY
CP2
CP2
CP2
DPPDPP
DEC
HDMI
AVIP
AVIP
AVIP
AVIP
AVIP
AVIP
AVIP
AVIP
AVIP
AVIP
AVIP AVIP
AVIP AVIP
AVIP AVIP
ENC AVIP
ENC AVIP
AVIP
AVIP
AVIP
AVIP
AVIP
AVIP
AVIP
AVIP
AVIP
AVIP AVIP
AVIP
COUNSEL TABLE **
COUNSEL TABLE **
DEC HDMI
DEC
DEC
HDMI
HDMI
HRX
HDBT
HRXHDBT
HRX
HDBT
HRX
HDBT
HRXHDBT
HRX
HDBT
DEC
DEC
DEC
CATEGORY 6A PATCH CORD, TYP.
CP4BCART
AVIP
9LECTERN
CP4A AVIP
AVIP
AVIP
DEC
HDMI
CP6A
AVIP
JUDGE'S BENCH
AVIP AVIP
CP9
AVIP
WELL **
AVIP
CP2
AVIP
COUNSEL TABLE **
AVIP
CP10 AVIPLAW CLERK AVIP
CP2 COUNSEL TABLE **
AVIP
AVIP
NC
AVIP AVIP DEC HDMI
SB
NC
HDBT
AVIP AVIP
WP
HDMI
HDMI
HDBT
HDBT
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
VIDEO SYSTEM SINGLE LINE DIAGRAM T602SALT LAKE CITY, UT
EQUIPMENT RACK
ENET
NOTE: FOR DRAWING CLARITY, SOME CONNECTION PANELS ARE SHOWN ON BOTH THE INPUT SIDE AND OUTPUT SIDE.
NC = NO CONNECTION
* INSTALL ON REAR RACK RAILS ** REFER TO UMBILICAL CORD DETAILS FOR MORE INFORMATION
NS
(CONTROL)
DPP
ENET
ENET
DPP
ENET
ENET
ENET
ENET
ENET
ENET
ENET
ENET
CP12
ENET
ENET
ENET
JUDGE'S BENCH
CP16TP
ENET
ENET
COURTROOM DEPUTY
CP15TP
ENET
FROM CS RS-232
ENET
WM
AS
WP
CP9A
FROM CS
RS-232
CRX
JUDGE IMAGE
HDBT
ENET ENET
FROM CS
RS-232
CRX
WITNESS IMAGE
HDBT
ENET ENET
FROM CS RS-232
CRX
LECTERN IMAGE
HDBT
ENET ENET
FROM CS RS-232
UPS
ENET ENET
FROM CS
RS-232
DSP
ENET ENET
RS-232
TSI
VOIP (2-LINES)
ENET ENET
CS
RS-232 TO WP
RS-232 TO CRX
RS-232 TO CRX
RS-232 TO CRX
RS-232 TO UPS
TO DSPRS-232
TO LIGHTING CONTROL
INTERFACE
RS-232
NC
RS-232
RELAY
TO MOTORIZED WINDOW
COVERING, TYP
RS-232
PR TYP
CP2
SENSING
FROM TEMP PROBE
SENSING
COUNSEL
CP5
SENSING
WITNESS
120 VAC
(TYP)
TVSS
TO ALL EQUIPMENT
UPS
ENET
ENET
CP4A ENET
ENET
CP2
SENSING
COUNSEL **
RS-232
TDA
CP9
CATEGORY 6A PATCH CORD, TYP.
GALLERY
GALLERY
ENET ENET
**CP4B CART
CP2
SENSING
COUNSEL **
CP2
SENSING
COUNSEL **
AVIP AVIP
CP9 WELL **
ENET
ENET
SM
CP7 COURTROOM DEPUTYUTX
TP
SB
FROM CS
RS-232
USBENETENET
TO MOTORIZED
PROJECTION SCREEN
RELAY
FROM COURT
NETWORK
CATEGORY 6A PATCH CORD, TYP.
NS
(VIDEO)
ENET
AVIP AVIP
AVIP AVIP
AVIP AVIP
FROM TEMP PROBE
SENSING
LECTERN
WITNESS
CP2
SENSING
COUNSEL **
RS-232 TO SB
RELAY
RELAY
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
CONTROL SYSTEM SINGLE LINE
DIAGRAM T603SALT LAKE CITY, UT
DATA OUTLET PINNING DETAIL
1 3 5 6 87
8 R4-BR/W
7 T4-W/BR
1 T2-W/O
4 R1-BL/W
PINNING (T568B)
RP4
2 4
2 R2-O/W
6 R3-GR/W
3 T3-W/GR
5 T1-W/BL
# COLOR
PIN RP/RP1
RP3
RP2
SPARE DATA CABLE SINGLE LINE DIAGRAM
EQUIPMENT RACK
DPP
CP12
CP4B
CP9
WITNESS
CART
CP8REPORTER
CP2COUNSEL TABLE
CP2COUNSEL TABLE
CP2COUNSEL TABLE
CP2COUNSEL TABLE
CP2COUNSEL TABLE
CP4ALECTERN
WELL
CP9GALLERY
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT DATA OUTLET PINNING DETAIL &
SPARE TIME DATA CABLE SINGLE LINE
DIAGRAM T604SALT LAKE CITY, UT
UMBILICAL CORD REQUIREMENTS
CABLE LABEL
FACTORY FABRICATED/INSTALLED
CABLE CONNECTORS
POWER
MODULE
NEMA 5
TVSSTO OTHER
EQUIPMENT, TYP
APPROX. 36" SPARE
CABLE, TYP
LEAD WEIGHT,
TYP, NOTE 4
HDMI
USB-C
COUNSEL TABLE
CABLE CUBBY - CP3B
CUSTOM NYLON LOOM
EXPANDABLE SLEEVING
JACKET
MIC-# 3 PIN XLR
IN LINE CONNECTOR,
TYP
NETWORK #
ENC
HDMI
APPROX LENGTH 10'
(CONFIRM W/OWNER PRIOR TO FABRICATION)
CAT 6, RJ-45
DEC MONITOR
AVIPHDMI
AFFIX UMBILICAL CORD INSIDE OF
COUNSEL TABLE FOR STRESS RELIEF
1. PROVIDE UMBILICAL CORDS WITH FACTORY INSTALLED CONNECTORS. DO NOT FABRICATE CONNECTORS ON SITE OR AT SHOP.
2. CONFIRM THE COURT'S DESIRED UMBILICAL CORD LENGTH PRIOR TO FABRICATION.
3. MOUNT ENCODERS, DECODERS, TRANSMITTERS, RECEIVERS, AND INTERFACES INSIDE MILLWORK.
4. AFFIX LEAD WEIGHT TO CABLE WITH NYLON WIRE TIE. PURPOSE IS TO ASSIST IN PULLING CABLE BACK INTO CUBBY.
NOTES:
MIC-# 3 PIN XLR
CAT 6, RJ-45
5. PROVIDE ONLY EXTRON CABLE CUBBY APPROVED CABLES FOR PULL-OUT PATCH CORDS INSIDE CABLE CUBBY.
SHIELDED CAT 6A, RJ-45
HS
HDMI
DP
POWER
MODULE
AV IN
AVIP
SHIELDED CAT 6A, RJ-45
ENET
HDA
HDMI
HDMI
7-PIN XLR INTERPERTER 7-PIN, XLR
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
COUNSEL TABLE UMBILICAL CORD
DETAIL & SINGLE LINE DIAGRAM T605SALT LAKE CITY, UT
LECTERN
CABLE CUBBY - CP3A
UMBILICAL CORD REQUIREMENTS
CABLE LABEL
FACTORY FABRICATED/INSTALLED
CABLE CONNECTORS
POWER
MODULE
NEMA 5
TVSSTO OTHER
EQUIPMENT, TYP
APPROX. 36" SPARE
CABLE, TYP
LEAD WEIGHT,
TYP, NOTE 4
HDMI
USB-C
CUSTOM NYLON LOOM
EXPANDABLE SLEEVING
JACKET
MIC-A 3 PIN XLR
IN LINE CONNECTOR,
TYP
AV IN
HDMI
APPROX LENGTH 10'
(CONFIRM W/OWNER PRIOR TO FABRICATION)
SHIELDED CAT 6A, RJ-45
AFFIX UMBILICAL CORD INSIDE OF
COUNSEL TABLE FOR STRESS RELIEF
1. PROVIDE UMBILICAL CORDS WITH FACTORY INSTALLED CONNECTORS. DO NOT FABRICATE CONNECTORS ON SITE OR AT SHOP.
2. CONFIRM THE COURT'S DESIRED UMBILICAL CORD LENGTH PRIOR TO FABRICATION.
3. MOUNT ENCODERS, DECODERS, TRANSMITTERS, RECEIVERS, AND INTERFACES INSIDE MILLWORK.
4. AFFIX LEAD WEIGHT TO CABLE WITH NYLON WIRE TIE. PURPOSE IS TO ASSIST IN PULLING CABLE BACK INTO CUBBY.
5. PROVIDE ONLY EXTRON CABLE CUBBY APPROVED CABLES FOR PULL-OUT PATCH CORDS INSIDE CABLE CUBBY.
NOTES:
MIC-B 3 PIN XLR
CAT 6, RJ-45
DEC MONITOR
AVIPHDMI
HDMI AVIP
DP
HS
SHIELDED CAT 6A, RJ-45
ENC
NETWORK # CAT 6, RJ-45
CART
DOCUMENT CAMERA INTENTIONALLY
DELETED FROM THIS PROJECT
ANNOTATION INTENTIONALLY
DELETED FROM THIS PROJECT
7" TOUCH PANEL INTENTIONALLY
DELETED FROM THIS PROJECT
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
LECTERN DESK UMBILICAL CORD
DETAIL & SINGLE LINE DIAGRAM T606SALT LAKE CITY, UT
MONITOR CAT 6A, RJ-45
UMBILICAL CORD REQUIREMENTS
CABLE LABEL CABLE CONNECTORS
FACTORY FABRICATED/INSTALLED
POWER NEMA 5
CUSTOM NYLON LOOM
EXPANDABLE SLEEVING JACKET
1. PROVIDE UMBILICAL CORDS WITH FACTORY INSTALLED CONNECTORS. DO NOT FABRICATE CONNECTORS ON SITE OR AT SHOP.
2. AFFIX TRANSMITTER TO UNDERSIDE OF TABLE.
3. APPLICABLE FOR ONE UMBILICAL CORD ONLY.
NOTES:
RS-232
PORTABLE STAND
APPROX LENGTH 20'
(CONFIRM W/OWNER PRIOR TO FABRICATION)
4. PROVIDE CONNECTORS AS RECOMMENDED BY THE MANUFACTURER OF THE HDBT SWITCHING SYSTEM.
GALLERY MONITOR UMBILICAL CORD DETAIL AND SINGLE LINE DIAGRAM
DEC AVIP
HDMI
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
GALLERY MONITOR UMBILICAL CORD
DETAIL & SINGLE LINE DIAGRAM T607SALT LAKE CITY, UT
HEADPHONE/MIC COMBO
MIC
APPROX 35' UMBILICAL
CORD W/ MULTI-PIN
CONNECTOR WHICH
MATES TO INDICATED
CONNECTION PANELS
MULTI-PIN CONNECTOR ON
CHASIS OF INTERPRETER'S
CONTROL PANEL, TYP
MIC ON/OFF SWITCH
INTERPRETER'S CONTROL PANEL
SPKRS
VOLUME CONTROL
HEADPHONE
BROADCAST SWITCH
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
INTERPRETER'S CONTROL PANEL
SINGLE LINE DIAGRAM T608SALT LAKE CITY, UT
CONNECTION PANEL #2 DETAIL, CP2 (COUNSEL TABLE)
CONNECTION PANEL #1 DETAIL, CP1
MIC # MIC #
3 PIN, XLR FEMALE TYPE
CONNECTOR, TYP.
MONITOR
SPARE # AV IN
7 PIN, XLR FEMALE
TYPE CONNECTOR
INTERPRETER
SPARE #
ENGRAVED TEXT FILLED WITH
CONTRASTING COLOR, TYP4 GANG, ALUMINUM OR
STEEL PLATE, COURT
TO SELECT COLOR
SHIELDED, CAT 6A,
RJ-45 FEMALE TYPE
CONNECTOR, TYP. CAT 6, RJ-45 TYPE
CONNECTOR, TYP
INSTALLER TO LOCATE EXISTING
FLOOR BOX PLATE SCREW HOLES
DURING THE PRE-INSTALLATION
SITE VISIT
NOT USED
SCALE:
SHEET TITLE: SHEET NO.
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
CONNECTION PANEL DETAILS T701SALT LAKE CITY, UT
CONNECTION PANEL #3B DETAIL CP3B (COUNSEL TABLE)
7 PIN XLR TYPE CONNECTOR
INSTALLED ON APPROX 36" OF "L"
TYPE CABLE, TYP
INTERPRETER
POWER
POWER
EXTRON 70-261-01 POWER MODULE, TYP
CAT 6, RJ-45 TYPE CONNECTOR INSTALLED ON
APPROXIMATELY 36" OF SPARE "D" TYPE CABLE,
TYP
NETWORK #
POWER
POWER
USB-C
HDMI
EXTRON CABLE CUBBY 800,
ARCHITECT TO SELECT
COLOR
BLANK PANEL
BLANK
FILLER
USB-C PULL-OUT PATCH CORD, 8K/30, MULTI-
STREAM TRANSPORT SUPPORT, USB HIGH
SPEED DATA RATES, USB POWER DELIVERY UP
TO 60 WATTS, ULTRA FLEXIBLE JACKET
HDMI PULL-OUT PATCH
CORD, 4K-60, HDMI 2.0,
18.0 Gbps, PREMIUM
HIGH SPEED ULTRA
FLEXIBLE JACKET
SCALE:
SHEET TITLE: SHEET NO.
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
CONNECTION PANEL DETAILS T702SALT LAKE CITY, UT
CONNECTION PANEL #3A DETAIL CP3A (LECTERN)
EXTRON 70-261-01
POWER MODULE, TYP
CAT 6, RJ-45 TYPE CONNECTOR INSTALLED
ON APPROXIMATELY 36" OF SPARE "D" TYPE
CABLE, TYP
NETWORK #
POWER
POWER
USB-C
USB-C PULL-OUT PATCH CORD, 8K/30, MULTI-
STREAM TRANSPORT SUPPORT, USB HIGH
SPEED DATA RATES, USB POWER DELIVERY UP
TO 60 WATTS, ULTRA FLEXIBLE JACKET
HDMI PULL-OUT PATCH
CORD, 4K-60, HDMI 2.0,
18.0 Gbps, PREMIUM
HIGH SPEED ULTRA
FLEXIBLE JACKET
HDMI
EXTRON CABLE CUBBY 800,
ARCHITECT TO SELECT
COLOR
BLANK PANEL
BLANK
FILLER,
TYP
BLANK PANEL
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
CONNECTION PANEL DETAILS T703SALT LAKE CITY, UT
CONNECTION PANEL #4A DETAIL, CP4A (LECTERN)
ENGRAVED TEXT FILLED WITH
CONTRASTING COLOR, TYP
MIC-A MIC-B
3 PIN, XLR FEMALE TYPE
CONNECTOR, TYP.
4 OR 6 GANG, ANODIZED ALUMINUM
OR POWDER COATED STEEL PLATE,
OWNER TO SELECT COLOR
ANNOTATION
SHIELDED CAT 6A, RJ-45
FEMALE TYPE
CONNECTOR, TYP
MONITORAV IN
CAT 6, RJ-45 TYPE
CONNECTOR, TYP
SPARE #
TOUCH PANEL
CONNECTION PANEL #4B DETAIL, CP4B (CART)
ENGRAVED TEXT FILLED WITH
CONTRASTING COLOR, TYP
4 OR 6 GANG, ANODIZED ALUMINUM
OR POWDER COATED STEEL PLATE,
OWNER TO SELECT COLOR
DOCUMENT
CAMERA
SHIELDED CAT 6A,
RJ-45 FEMALE TYPE
CONNECTOR, TYP
CAT 6, RJ-45 TYPE
CONNECTOR, TYP
SPARE #
SPARE # SPARE # SPARE #
INSTALLER TO
LOCATE EXISTING
FLOOR BOX PLATE
SCREW HOLES
DURING THE PRE-
INSTALLATION SITE
VISIT
INSTALLER TO
LOCATE EXISTING
FLOOR BOX
PLATE SCREW
HOLES DURING
THE PRE-
INSTALLATION
SITE VISIT
SCALE:
SHEET TITLE: SHEET NO.
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
CONNECTION PANEL DETAILS T704SALT LAKE CITY, UT
CONNECTION PANEL #6A DETAIL, CP6A (JUDGE)
2 GANG, ALUMINUM OR
POWDER COATED STEEL PLATE,
COURT TO SELECT COLOR
SHIELDED CAT 6A,
RJ-45 FEMALE TYPE
CONNECTOR, TYP
CAT 6, RJ-45 TYPE
CONNECTOR, TYP
MONITOR
ENGRAVED TEXT
FILLED WITH
CONTRASTING
COLOR, TYP
WAP
CONNECTION PANEL #5 DETAIL, CP5 (WITNESS)
DESK MIC #
LAV MIC
7 PIN, XLR FEMALE
TYPE CONNECTOR
ENGRAVED TEXT FILLED
WITH CONTRASTING
COLOR, TYP
INTERPRETER
DESK MIC #
3 PIN, XLR FEMALE
TYPE CONNECTOR,
TYP
2 GANG, ANODIZED ALUMINUM OR
POWDER COATED STEEL PLATE,
OWNER TO SELECT COLOR
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
CONNECTION PANEL DETAILS T705SALT LAKE CITY, UT
CONNECTION PANEL #7 DETAIL, CP7 (COURTROOM DEPUTY)
2 GANG, ALUMINUM OR STEEL PLATE,
COURT TO SELECT COLOR
SHIELDED CAT 6A, RJ-45
FEMALE TYPE
CONNECTOR, TYP
AV IN
ENGRAVED TEXT
FILLED WITH
CONTRASTING
COLOR, TYP
ANTENNA BNC TYPE CONNECTOR, TYP.
(AT CRD LOCATION ONLY)
CAT 6, RJ-45 TYPE
CONNECTOR, TYP
VTC USB
VTC AUDIO
.125" TRS TYPE
CONNECTOR W/
INTEGRATED BALANCING
TRANSFORMER SUCH AS
QUANTUM 002520-V2
(BEHIND PLATE), TYP
WRLS SIDE BAR REC
CONNECTION PANEL #6B DETAIL, CP6B (COURTROOM DEPUTY)
2 GANG, ALUMINUM OR
POWDER COATED STEEL PLATE,
COURT TO SELECT COLOR
SHIELDED CAT 6A,
RJ-45 FEMALE TYPE
CONNECTOR, TYP
CAT 6, RJ-45 TYPE
CONNECTOR, TYP
MONITOR
ENGRAVED TEXT
FILLED WITH
CONTRASTING
COLOR, TYP
CHARGING BASE
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:3
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
CONNECTION PANEL DETAILS T706SALT LAKE CITY, UT
CONNECTION PANEL #9 DETAIL, CP9 (GALLERY/WELL)
ENGRAVED TEXT
FILLED WITH
CONTRASTING
COLOR, TYP
SHIELDED CAT 6A, RJ-45
FEMALE TYPE
CONNECTOR, TYP
4 GANG, ALUMINUM OR POWDER COATED
STEEL PLATE, COURT TO SELECT COLOR
MONITOR
SPARE #
CAT 6, RJ-45 TYPE
CONNECTOR, TYP
INSTALLER TO LOCATE EXISTING
FLOOR BOX PLATE SCREW HOLES
DURING THE PRE-INSTALLATION
SITE VISIT
CONNECTION PANEL #8 DETAIL, CP8 (REPORTER)
ENGRAVED TEXT
FILLED WITH
CONTRASTING
COLOR, TYP
SHIELDED CAT 6A, RJ-45
FEMALE TYPE
CONNECTOR, TYP
2 GANG, ALUMINUM OR
POWDER COATED STEEL PLATE,
COURT TO SELECT COLOR
MONITOR
CAT 6, RJ-45 TYPE
CONNECTOR, TYP
DIG. REC. OUT
SPARE #
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:4
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
CONNECTION PANEL DETAILS T707SALT LAKE CITY, UT
CONNECTION PANEL #10 DETAIL, CP10 (LAW CLERK)
ENGRAVED TEXT FILLED
WITH CONTRASTING
COLOR, TYP
2 GANG, ALUMINUM OR
POWDER COATED STEEL PLATE,
COURT TO SELECT COLOR
CAT 6, RJ-45 TYPE
CONNECTOR, TYP
AV IN
MONITOR
SHEILDED CAT 6A, RJ-45
FEMALE TYPE
CONNECTOR, TYP
CONNECTION PANEL #9A DETAIL, CP9A (GALLERY)
ENGRAVED TEXT FILLED
WITH CONTRASTING
COLOR, TYP
SHIELDED CAT 6A, RJ-45
FEMALE TYPE
CONNECTOR, TYP
4 GANG, ALUMINUM OR POWDER COATED
STEEL PLATE, COURT TO SELECT COLOR
MONITOR
MONITOR
CAT 6, RJ-45 TYPE
CONNECTOR, TYP
INSTALLER TO LOCATE EXISTING
FLOOR BOX PLATE SCREW HOLES
DURING THE PRE-INSTALLATION
SITE VISIT
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:4
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
CONNECTION PANEL DETAILS T708SALT LAKE CITY, UT
CONNECTION PANEL #11 DETAIL, CP11 (JUDGE)
ENGRAVED TEXT FILLED
WITH CONTRASTING
COLOR, TYP
3 PIN, XLR
FEMALE TYPE
CONNECTOR, TYP
BENCH CONF.
DESK MIC #
LAV MIC
2 GANG, ALUMINUM OR
POWDER COATED STEEL PLATE,
COURT TO SELECT COLOR
DESK MIC #
CONNECTION PANEL #12 DETAIL, CP12 (WITNESS)
ENGRAVED TEXT FILLED
WITH CONTRASTING
COLOR, TYP
SHIELDED CAT 6A, RJ-45
FEMALE TYPE
CONNECTOR, TYP
2 GANG, ALUMINUM OR
POWDER COATED STEEL PLATE,
COURT TO SELECT COLOR
AV IN
ANNOTATION CAT 6, RJ-45 TYPE
CONNECTOR, TYP
SPARE #
DESK SPKR
.25" TRS TYPE
CONNECTOR
MONITOR
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:4
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
CONNECTION PANEL DETAILS T709SALT LAKE CITY, UT
CONNECTION PANEL #13 DETAIL, CP13 (REPORTER)
ALL MICS
RECORD OUT
PLAYBACK
2 GANG, ALUMINUM OR
POWDER COATED STEEL PLATE,
COURT TO SELECT COLOR
ENGRAVED TEXT FILLED
WITH CONTRASTING
COLOR, TYP
.125" TRS TYPE
CONNECTOR W/
INTEGRATED BALANCING
TRANSFORMER SUCH AS
QUANTUM 002520-V2
(BEHIND PLATE), TYP
DESK SPKR
.25" TRS TYPE
CONNECTOR
HEADPHONES.125" TRS TYPE
CONNECTOR
CONNECTION PANEL #14 DETAIL, CP14 (REPORTER)
ENGRAVED TEXT FILLED
WITH CONTRASTING
COLOR, TYP
3 PIN, XLR MALE
TYPE CONNECTOR
2 GANG, ALUMINUM OR
POWDER COATED STEEL PLATE,
COURT TO SELECT COLOR
RECORD OUT
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:4
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
CONNECTION PANEL DETAILS T710SALT LAKE CITY, UT
RJ-45 TYPE
CONNECTOR, TYP
2 GANG, ALUMINUM OR
POWDER COATED STEEL PLATE,
COURT TO SELECT COLOR
TOUCH PANEL
CONNECTION PANEL #15 DETAIL, CP15 (COURTROOM DEPUTY)
DESK SPKR
ENGRAVED TEXT FILLED
WITH CONTRASTING
COLOR, TYP
MIC
3 PIN, XLR FEMALE
TYPE CONNECTOR
.25" TRS TYPE
CONNECTOR
ANTENNA
BNC TYP CONNECTOR
(AT CRD LOCATION
ONLY)
RJ-45 TYPE
CONNECTOR, TYP
2 GANG, ALUMINUM OR
POWDER COATED STEEL PLATE,
COURT TO SELECT COLOR
TOUCH PANEL
CONNECTION PANEL #16 DETAIL, CP16 (JUDGE)
DESK SPKR
ENGRAVED TEXT FILLED
WITH CONTRASTING
COLOR, TYP
.25" TRS TYPE
CONNECTOR
HEADPHONES
.125" TRS TYPE
CONNECTOR
SHIELDED CAT 6A, RJ-45
FEMALE TYPE
CONNECTOR, TYP
AV IN
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:4
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
CONNECTION PANEL DETAILS T711SALT LAKE CITY, UT
T A
P A
T C
H P
A N
E L D
E T
A
IL
C O
N N
E C
T
IO
N P
A N
E L
D
E T
A
IL
C
P
A V
R A
C K
H D
M I T
Y P
E C
O N
N E
C T
O R
T
Y P
R
U R
A C
K P
A N
E L
-P
IN
X
L R
M A
L E
T Y
P E
C O
N N
E C
T O
R T
Y P
E N
G R
A V
E D
T E
X T
F
IL
L E
D W
IT
H
C O
N T
R A
S T
IN
G
C O
L O
R
V
R
E A
M
IN
G
U
T P
U T
V
ID
E O
A U
D
IO
A U
D
IO
M A
R S
H A
L O
U T
P U
T
R
U P
A N
E L
P R
O V
ID
E
M A
C H
IN
E
P R
IN
T
E D
L A
B E
A
T M
A T
C H
F
IE
L D
E
N D
O F
C A
B L E
S
H
IE
L D
T
E G
O
Y
R
J -4
T
Y P
E C
O N
N E
C T
O R
T
Y P
X X
X X
X X
X X
X X
X X
X X
X X
SCALE:
SHEET TITLE: SHEET NO.
NO SCALE8
/6
/2
:2
:4
A
M C
U s e rs
\m lt \D o c u m e n ts \R e v it
L o c a l\
S a lt L a k e C it y C
R
.4 m in d y .t a n g n e y .r v t
U.S. DISTRICT COURT
CONNECTION PANEL DETAILS T712SALT LAKE CITY, UT
II. SPECIFICATIONS
UNITED STATES FEDERAL COURTHOUSE - SALT LAKE CITY, UTAH
SECTION 27 41 16.01- GENERAL TECHNOLOGY SYSTEMS REQUIREMENTS
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of Contract, including General and Supplementary Conditions apply to this section of Division 27.
1.2 SUMMARY
A. This Section includes general requirements for audio/video installations:
1. Summary of work.
2. Project Coordination.
3. References and Standards.
4. Industry Standards.
5. Unit Prices.
6. Submittals.
7. Materials and Equipment.
8. Summary Test Report.
9. Warranties.
1.3 SUMMARY OF WORK
A. General: Comply with requirements of Owner for completion of work. The work will be conducted to provide the least possible interference to the activities of the Owner's personnel and operations.
B. The work consists of, but is not limited to, the construction of integrated audio, video, and control systems.
C. Owner furnished items: The Owner may furnish material and equipment as indicated in the contract documents, including Schedule B, to be incorporated into the Work.
These items are assigned to the installer and costs for receiving, handling, storage, if required, and installation are included in the Contract Sum.
1. The Installer's responsibilities are the same as if the Installer furnished the materials or equipment.
2. The Owner will arrange and pay for delivery of Owner-furnished items FOB job site and the installer will inspect deliveries for damage. If Owner-furnished items are damaged, defective or missing, document damaged items with the transport company and the Owner will arrange for replacement. The Owner will also arrange for manufacturer's field services, and the delivery of manufacturer's warranties and bonds to the Installer.
3. The Installer is responsible for designating the delivery dates of Owner-furnished items and for receiving, unloading and handling Owner-furnished items at the site.
This is the start of the file's text. The full file is on GovTribe.