240361_McKinney_Campus_Phase_II_-_Reroof_Sealant_EIFS_Scope_-_5-2-25_-_reduced_file_size_-_updated_cover_and_index.pdf

PDF 5 MB Posted

Attached to
McKinney Campus Phase II Re-roof
Solicitation number
FY2025-CSP-026
Issued by
Collin County, Texas

About this file

This document is a comprehensive bid package for the McKinney Campus Phase II Re-roof project for Collin College in McKinney, Texas, dated May 2, 2025. The project encompasses multiple scope options including a base bid for replacing built-up roof with gravel roof areas and modified bitumen roof areas, involving complete tear-off of existing roof assemblies down to the metal deck, removal of existing metal copings, roof edges, and gutters, and installation of a new roof system. The new roofing system will include mechanically attached and fully adhered polyisocyanurate insulation, a high-density cover board, and an 80 mil thermoplastic membrane with a 20-year No Dollar Limit (NDL) warranty. Additional alternates include a deductive option for recovering modified bitumen roof areas, a sealant scope with options for silicone or polyurethane materials, and an EIFS (Exterior Insulation and Finish System) repair and recoating scope.

The project requires comprehensive roof restoration across approximately 24,310 square feet of roofing area, with detailed specifications for handling existing roof components, mechanical equipment, penetrations, and drainage systems. Contractors are expected to provide precise pricing for various scope options, including new metal fabrications, flashing, counterflashing, and expansion joint treatments. The bid package includes extensive technical details, roof area information, keyed notes, and photographic documentation of existing conditions, emphasizing the need for careful site assessment, precise installation techniques, and maintenance of watertight conditions. The project appears to be funded through the college's capital improvement budget, with a focus on long-term performance and warranty protection for the roofing systems.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BEAM PROJECT: 240361

ISSUE FOR BID

MAY 2, 2025

COLLIN COLLEGE

BEAM Professionals 14001 Dallas Parkway Suite 400 Dallas, TX 75240 972-233-1373 P BEAMProf.com

McKINNEY CAMPUS PHASE II

RE-ROOF

KEY PLAN

CHECKED BY

DRAWN BY

DATE

PROJECT NUMBER

CLIENT

N

N

TRUE

NORTH

PLAN

NORTH

REVISIONS

DESCRIPTION DATENo.

M C

KI

N

N

EY

C

AM

PU

S

PH

AS

E

II

R E-

R O

O F

W U

N

IV

ER

SI

TY

D

R M

C

KI

N N

EY

, T

X

C O

LL

IN

C O

LL

EG

E

COLLIN COLLEGE

240361

05/02/2025

JH

CG

ISSUE FOR BID

BEAM Professionals 14001 Dallas Parkway

Suite 400 Dallas, TX 75240 972-233-1373 P BEAMProf.com

5-2-25

GENERAL INFORMATION

SHEET

G-0

GENERAL SHEETS

CVR COVER SHEET

G-0 GENERAL INFORMATION

BUILDING ENVELOPE

A-1 COMPOSITE ROOF PLAN

A-1.1 ENLARGED ROOF PLAN

A-1.2 SEALANT SCOPE

A-2 ROOF DETAILS

A-3 SEALANT SCOPE PHOTOS

A-4 EIFS SCOPE PHOTOS

COLLIN COLLEGE MCKINNEY CAMPUS

2200 W UNIVERSITY DR, MCKINNEY, TX 75071

SCOPE OF WORK

BUILT-UP ROOF WITH GRAVEL ROOF AREAS - BASE BID

TEAR OF EXISTING ROOF ASSEMBLY DOWN TO METAL DECK. REMOVE ALL EXISTING

METAL COPINGS, ROOF EDGE, GUTTER, ETC.

INSTALL NEW ROOF SYSTEM CONSISTING OF 2 LAYERS OF 2.2” POLYISOCYANURATE

INSULATION, FIRST LAYER MECHANICALLY ATTACHED, AND SECOND LAYER FULLY

ADHERED. INSTALL NEW FULLY ADHERED ½” HIGH DENSITY COVER BOARD. INSTALL

NEW 80 MIL THERMOPLASTIC MEMBRANE TO BE FULLY ADHERED. PROVIDE ALL

REQUIRED FLASHING AND PIPE PENETRATION ASSEMBLIES FOR NEW 20 YEAR NDL

WARRANTIED ROOF SYSTEM. PROVIDE NEW PREFINISHED METAL COPINGS, ROOF

EDGE, GUTTER, DOWNSPOUTS, AND OTHER METAL FABRICATIONS REQUIRED FOR

FLASHING, COUNTERFLASHING, THROUGH-WALL RECEIVERS, AND PENETRATIONS. ALL

NEW COUNTERFLASHINGS, RECEIVER, AND EXPANSION JOINTS TO BE STAINLESS STEEL

UNLESS VISIBLE FROM THE GROUND.

MODIFIED BITUMEN ROOF AREAS - BASE BID

TEAR OF EXISTING ROOF ASSEMBLY DOWN TO METAL DECK. REMOVE ALL EXISTING

METAL COPINGS, ROOF EDGE, GUTTER, ETC.

INSTALL NEW ROOF SYSTEM CONSISTING OF 2 LAYERS OF 2.2” POLYISOCYANURATE

INSULATION, FIRST LAYER MECHANICALLY ATTACHED, AND SECOND LAYER FULLY

ADHERED. INSTALL NEW FULLY ADHERED ½” HIGH DENSITY COVER BOARD. INSTALL

NEW 80 MIL THERMOPLASTIC MEMBRANE TO BE FULLY ADHERED. PROVIDE ALL

REQUIRED FLASHING AND PIPE PENETRATION ASSEMBLIES FOR NEW 20 YEAR NDL

WARRANTIED ROOF SYSTEM. PROVIDE NEW PREFINISHED METAL COPINGS, ROOF

EDGE, GUTTER, DOWNSPOUTS, AND OTHER METAL FABRICATIONS REQUIRED FOR

FLASHING, COUNTERFLASHING, THROUGH-WALL RECEIVERS, AND PENETRATIONS. ALL

NEW COUNTERFLASHINGS, RECEIVER, AND EXPANSION JOINTS TO BE STAINLESS STEEL

UNLESS VISIBLE FROM THE GROUND. PROVIDE AND INSTALL NEW ROOF HATCH.

MODIFIED BITUMEN ROOF AREAS - DEDUCTIVE ALTERNATE #1

LEAVE EXISTING MODIFIED ROOF SYSTEM IN PLACE. FULLY ADHERE NEW ½” HIGH

DENSITY COVER BOARD 4'-0” X 4'-0” SIZE. ENSURE THAT COVER BOARDS ARE WEIGHTED

ONCE SET IN ADHESIVE UNTIL ADHESIVE HAS CURED. INSTALL NEW FULLY ADHERED

FLEECE-BACKED THERMOPLASTIC MEMBRANE TO NEW COVER BOARD. PROVIDE NEW

PREFINISHED METAL COPINGS AND ROOF EDGES, AS WELL AS NEW UNDERLAYMENT

BENEATH NEW COPINGS AND ROOF EDGES. INSTALL NEW COUNTERFLASHINGS AND

ADDRESS DRAIN TARGETS / REMOVE AND REINSTALL CLAMPING RINGS TO PROVIDE

WATERTIGHT SYSTEM. PROVIDE NEW BASE FLASHINGS, CURB FLASHINGS, AND PIPE

PENETRATION FLASHINGS AS REQUIRED.

SEALANT SCOPE BASE BID

SEALANT SCOPE - DEDUCTIVE ALTERNATE #2

EIFS SCOPE - ADD ALTERNATE #1

1. CONTRACTOR SHALL VISIT SITE TO ASCERTAIN EXACT EXISTING CONDITIONS AND

COMPONENTS RELATED TO THE WORK DESCRIBED BY THESE DOCUMENTS. AFTER

AWARD OF THE CONTRACT, CHANGE ORDER REQUEST FOR ADDITIONAL MONEY

SHALL NOT BE APPROVED IF THE WORK COULD HAVE BEEN ANTICIPATED DURING

THE SITE VISIT BY THE CONTRACTOR, ALL WORK SHALL BE COMPLETED IN

ACCORDANCE WITH ACCEPTED MANUFACTURER'S PRINTED INSTRUCTIONS AND

WARRANTY REQUIREMENTS.

2. DIMENSIONS, DETAILS, EQUIPMENT SIZE AND LOCATION SHOWN IN THESE

CONSTRUCTION DOCUMENTS ARE FOR CONVEYANCE OF DESIGN INTENT ONLY.

EXACT SIZE, LOCATION, TYPE OF MATERIAL AND TYPE OF CONSTRUCTION OF

EXISTING CONDITIONS ARE THE RESPONSIBILITY OF THE CONTRACTOR TO

ASCERTAIN AND CONFIRM.

3. REFER TO NOMENCLATURE FOR TYPE OF ROOF SYSTEM. ROOF AREAS ARE MARKED

WITH DESIGNATED LETTER ON ROOF PLAN.

4. NOTE THAT SOME OF THE DETAILS DRAWN ARE GENERIC IN NATURE AND ARE NOT

NECESSARILY LOCATED AND KEYED TO THE ROOF PLANS.

5. INDICATED ROOF HEIGHTS ARE GENERAL IN NATURE.

6. ALL NEW CRICKETS AND TAPERED INSULATION SHALL BE INSTALLED WITH A FINISHED

1/4" PER FOOT MIN. SLOPE. CRICKET THE UP SLOPE SIDE OF ALL SQUARE CURBS

AND PROJECTIONS OVER 20" IN WIDTH.

7. REMOVE ALL ABANDONED EQUIPMENT IDENTIFIED ON SITE AND AS SHOWN ON

OTHERWISE ON THESE DOCUMENTS.

8. REPLACE ROTTED AND / OR OTHERWISE DETERIORATED ROOF DECK MATERIAL WITH

LIKE MATERIAL AND THICKNESS.

9. REPLACE ROTTED AND / OR OTHERWISE DETERIORATED WOOD NAILER MATERIAL

WITH LIKE MATERIAL AND THICKNESS.

10. PATCH EXISTING ROOF DECK FOR HOLES LESS THAN 10" WIDE BY ANCHORING 22 GA.

STAINLESS STEEL SHEET METAL TO BOTTOM OF EXISTING STEEL ROOF DECK TO

MATCH EXISTING THICKNESS. PATCH EXISTING ROOF DECK FOR HOLES GREATER

THAN 10" WIDE BY ANCHORING 22 GA. STAINLESS STEEL SHEET METAL TO BOTTOM

OF EXISTING GYPSUM ROOF DECK SPANNING FROM JOIST TO JOIST.

11. AS APPLICABLE, ALL HVAC AND / OR DX UNITS, ELECTRICAL TRANSFORMERS, ROOF

TOP EQUIPMENT, ETC. THAT ARE ON SLEEPERS SHALL BE DISCONNECTED /

REMOVED, RAISED, AND PLACED ON NEW CURBED PLATFORMS AS DETAILED AND

REINSTALLED / RECONNECTED. ALL CURB MOUNTED HVAC UNITS, EQUIPMENT, ETC.

SHALL HAVE A MINIMUM 8" CURB HEIGHT AND ARE TO BE RAISED AS REQUIRED.

12. ALL DISCONNECTS AND RECONNECTS SHALL BE PERFORMED BY A LICENSED

ELECTRICIAN.

13. WORK TO ANY EXISTING UTILITY CONDUIT OR PIPE SHALL BE PERFORMED BY

SPECIFIC LICENSED SUBCONTRACTORS SPECIALIZING IN HVAC, PLUMBING AND

ELECTRICAL WORK. PERMITS AND INSPECTIONS ARE REQUIRED. REROUTE AND / OR

MODIFY UTILITY CONDUIT OR PIPE AS REQUIRED TO BE INSTALLED AS DETAILED.

14. UNLESS INDICATED OTHERWISE ON THE CONSTRUCTION DOCUMENTS, REPLACE AND

RAISE (AS REQUIRED) ALL EXISTING EXPANSION JOINTS / AREA DIVIDERS / CURB

MOUNTED EQUIPMENT / EXISTING ROOF HATCH/ SKYLIGHTS A MIN. 10" ABOVE ROOF

DECK.

15. ALL SOIL STACK FLASHING SHALL BE A MIN. 8" ABOVE FINISHED ROOF SURFACE.

COUPLE PVC PIPE ABOVE DECK AND COUPLE CAST IRON PIPE BELOW DECK.

16. ALL PIPING/ CONDUIT/ ETC. SHALL BE A MIN. 8" ABOVE ROOF SURFACE. PROVIDE

PORTABLE PIPE HANGERS WITH PROTECTION PADS.

17. PROVIDE SHEET METAL HOODED (WITH METAL FACE CLOSURE) CAPS, WOOD WOOD

CURB, BOX COVER AT ALL GAS AND WATER PIPE ROOF PENETRATIONS AS DETAILED.

PROVIDE POSITIVE SLOPE AWAY FROM FACE COVER.

18. PROVIDE WALKWAY PROTECTION PADS AS SPECIFIED AROUND ALL ROOF HATCHES,

HVAC ROOFTOP UNITS, DOORS THAT OPEN ONTO ROOF AND AT TOP AND BOTTOM OF

ALL ROOF TOP ACCESS LOCATIONS.

19. INSTALL NEW SPLASH PAN AT ALL LOCATIONS WHERE ROOF DRAINAGE DISCHARGES

ONTO ROOF AREA. INSTALL NEW SPLASH BLOCKS WHERE ROOF DRAINAGE

DISCHARGES ON GROUND.

20. ISOLATE ALL HEAT PIPES / FLUES AS DETAILED AND RECOMMENDED AND OUTLINED

IN THE NRCA MANUAL FOR HOT STACK FLASHING.

21. ALL OUTSIDE AIR INTAKES SHALL BE COVERED TO ELIMINATE ODORS AND FUMES

FROM ENTERING INTO THE BUILDING DURING CONSTRUCTION WORK.

22. EXAMINE AND CLEAN EXISTING DRAIN LINES OF DEBRIS AND BLOCKAGE, FLUSH WITH

WATER TO ENSURE THAT DRAINS FLOW FREELY. REPAIR EXISTING DRAINS AS

REQUIRED.

23. OWNER WILL VERIFY PROPER OPERATION OF ALL ROOF TOP EQUIPMENT BEFORE

AND AFTER THE PROJECT. CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFYING

ALL INOPERABLE EQUIPMENT PRIOR TO RELEASE OF PROJECT.

24. REPLACE ALL RUSTED AND / OR DETERIORATED EXISTING METAL VENT FLASHING

AND FLUES.

25. PRIOR TO COMMENCEMENT OF WORK, COORDINATE WALK OF ENTIRE ROOF WITH

ROOFING MANUFACTURER'S TECHNICAL REPRESENTATIVE TO IDENTIFY AND LOCATE

ALL AREAS OF HIGH SLOPE OR OTHER CONDITIONS WHICH MIGHT REQUIRE SPECIAL

PROCEDURES FOR SYSTEM ATTACHMENT.

26. PAINT ALL EXPOSED GAS PIPE TO REMAIN.

27. EXISTING OVERFLOW DRAIN LINE PIPES ARE TO BE REPLACED WITH OVERFLOW

ROOF DRAIN ASSEMBLIES PER PLUMBING SPECIFICATIONS.

MCKINNEY CAMPUS

INDEX OF DRAWINGS

SCOPE OF WORK

GENERAL NOTES

SITE MAP

VICINITY MAP

AutoCAD SHX Text AT ALL DOOR AND WINDOW OPENINGS, CONTROL JOINTS, EXPANSION JOINTS, PENETRATIONS, ETC. THROUGHOUT THE ENTIRE FACADE TO THE EXTENTS SHOWN ON SHEET A-3 (TO START AND STOP WHERE THE BUILDING MEETS THE GARAGE), REMOVE EXISTING SOFT JOINTS AND REPLACE WITH NEW BACKER ROD AND SILICONE SEALANT JOINTS TO MATCH EXISTING COLOR. THIS SHALL ALSO INCLUDE ALL SOFT JOINTS BETWEEN CAST STONE / MASONRY ELEMENTS AND AT SOFT JOINTS WHERE FACADE MATERIALS TRANSITION TO DIFFERENT FACADE MATERIALS. SAME SCOPE AS ABOVE, BUT PROVIDE PRICING FOR USING POLYURETHANE SEALANT IN LIEU OF SILICONE SEALANT. INFILL ALL HOLES / CRACKS / DAMAGE OF EXISTING EIFS SYSTEM WITH NEW FOAM AS SHOWN BY EXTENTS INDICATED ON DRAWING. THE EXTENTS ARE INTENDED TO INDICATE ALL INSTANCES / LOCATIONS OF EIFS THROUGHOUT THE FACILITY. REMOVE ANY EXISTING CEMENTITIOUS BASE COAT AND TOP COATS AS NEEDED TO REPAIR INSULATION / FOAM. SAND / CONTOUR / SHAPE NEW FOAM AS REQUIRED TO ACHIEVE ACCEPTABLE SUBSTRATE. PROVIDE NEW CEMENTITIOUS BASE AND TOP COATS WITH REINFORCING MESH AT ALL LOCATIONS OF DAMAGE / DETERIORATED EIFS SYSTEM. PROVIDE ACRYLIC ELASTOMERIC COATING THROUGHOUT THE ENTIRETY OF THE EIFS SYSTEM TO MATCH EXISTING COLOR AND TEXTURE, OR COLOR AS SELECTED BY OWNER. SEAL EIFS SYSTEM AT ALL TRANSITIONS TO ALL DIFFERING ADJACENT CLADDING MATERIALS WITH A COMPATIBLE SEALANT PRODUCT. SEAL ALL LOCATIONS OF CONTROL JOINTS OR EXPANSION JOINTS WITHIN EIFS SYSTEM. REMOVE AND REPLACE PREFINISHED METAL COPING CAP AS NEEDED TO REPAIR AND COAT EIFS SYSTEM. REINSTALL COPING. ENSURE THAT SEAM INTEGRITY IS MAINTAINED DURING REMOVAL AND REINSTALLATION. USE NEW OVERSIZED GROMMETED FASTENERS WHEN INSTALLING EXISTING COPING.

OFSC

OFSC

OFSC

OFSC OFSC OFSC OFSC

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJEJEJEJEJEJEJEJ

EJ

EJ

EJ

EJ

O

FS

C O

FS

C

O

FS

C

NIC

NIC

NIC

NIC

NICNIC

A1

A2

B1

B2 C1

C2 A/C

A/C

EJ EJ EJ EJ EJ EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ EJ EJ

EJ

EJ

EJ EJ EJ EJ EJ EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

A/C

A/C

A/C

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

G

G

G

G

G

G v v

DS

DS

DS

DS

A/C

A/C

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

W W

W W

W W

W

W W

W W

W W

W

C D

C D

SLO

PE

SLO

PE

SLO

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SLOPE SLOPE

SLOPE SLOPE

SL

O

PE

SL

O

PE

1 PROVIDE NEW STAINLESS STEEL METAL AROUND COLUMNS, TYPICAL.

2 RAISE UNIT AS REQUIRED TO INSTALL CURB FLASH AND RESET UNIT ON EXISTING

NEWLY FLASHED CURB.

3 EXISTING PITCH PAN. REMOVE. INSTALL NEW LIQUID FLASHING AT EXISTING

PENETRATION.

4 EXISTING GAS LINE. DISCONNECT AND RECONNECT AS REQUIRED TO INSTALL NEW

CURB FLASHING AND NEW ROOF. TEXT / RECERTIFY GAS LINE AS REQUIRED BY STATE

OF TEXAS.

5 LIFT UNIT TO INSTALL NEW BASE FLASHINGS AT EXISTING CURB. SET UNIT BACK ONTO

NEWLY FLASHED EXISTING CURB. MAINTAIN EXISTING CURB CAP AND CURB ADAPTOR.

PROVIDE NEW OVERSIZED GROMMETED FASTENERS TO REATTACH METAL CURB CAP.

6 SUMP INSULATION LAYERS DOWN TO EXISTING DRAIN BOWL HEIGHT.

7 PROVIDE TEMPORARY SUPPORT FOR INSULATED LINES ON TRAPEZE HANGERS. ENSURE

THAT INSULATED LINES REMAIN OPERATIONAL AND UNDAMAGED DURING

CONSTRUCTION. PROVIDE PROTECTION PADS BENEATH ALL PIPE SUPPORTS, TYPICAL.

8 PROVIDE BLOCKING WITHIN SCUPPER ROUGH OPENING POST TEAR-OFF TO RAISE BASE

OF SCUPPER TO ACCOMMODATE NEW ROOF ELEVATION. REFLASH SCUPPER AND

PROVIDE NEW SCUPPER METAL TO MATCH EXISTING COLOR, TYPICAL.

9 REMOVE EXISTING COUNTERFLASHING TO INSTALL NEW ROOF MEMBRANE. INSTALL

NEW STAINLESS STEEL COUNTERFLASHING, TYPICAL.

10 PROVIDE NEW STAINLESS STEEL THYCURB CAPS, TYPICAL. DO NOT FASTEN INTO TOP

OF CURB CAP. ANCHOR UNIT TO SIDE OF THYCURB CAPS VIA BRACKETS, TYPICAL.

11 PROVIDE NEW SPLASH ON PROTECTION PADS AT ROOF TO ROOF DISCHARGE, TYPICAL.

KEYED NOTES

CHECKED BY

DRAWN BY

DATE

PROJECT NUMBER

CLIENT

N

N

TRUE

NORTH

PLAN

NORTH

REVISIONS

DESCRIPTION DATENo.

M C

KI

N

N

EY

C

AM

PU

S

PH

AS

E

II

R E-

R O

O F

W U

N

IV

ER

SI

TY

D

R M

C

KI

N N

EY

, T

X

C O

LL

IN

C O

LL

EG

E

COLLIN COLLEGE

240361

05/02/2025

JH

CG

ISSUE FOR BID

BEAM Professionals 14001 Dallas Parkway

Suite 400 Dallas, TX 75240 972-233-1373 P BEAMProf.com

5-2-25

COMPOSITE ROOF PLAN

A-11 COMPOSITE ROOF PLAN

1/32" = 1'-0"

A

AREA

APROX. SQ.

FT. EXISTING NOMENCLATURE

NEW

NOMENCLATURE REMARKS

A1 1000 MTLD/ 1/8" S/ 4" EPS/ 2" LWIC/ MB A 1

A2 1000 MTLD/ 1/8" S/ 4" EPS/ 2" LWIC/ MB A 1

B1 6050 MTLD/ 1/8" S/ 4" EPS/ 2" LWIC/ MB A 1

B2 13860 MTLD/ 1/8" S/ 4" EPS/ 2" LWIC/ MB A 1

C1 1200 BUR-G A 1

C2 1200 BUR-G A 1

TOTAL 24310

NOTE: SQUARE FOOTAGES SHOWN ARE FOR REFERENCE ONLY - (FIELD VERIFY)

CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING CONDITIONS AND FOR

ENSURING NEW CONDITIONS ADHERE TO ALL LOCAL AND FEDERAL CODES ALONG WITH

INDUSTRY STANDARD GUIDELINES AND REMAIN IN A WATERTIGHT CONDITION.

ABBREVIATIONS:

ISO: ISO BOARD INSULATION

EPS: EXTRUDED POLYSTYRENE INSULATION BOARD

LWIC: LIGHT WEIGHT INSULATING CONCRETE

MTLD: METAL DECK

BUR-G: MULTI-PLY COAL TAR BUILT-UP ROOF SYSTEM W/GRAVEL

MB: 2 PLY MODIFIED BITUMEN ROOF SYSTEM

TPO: THERMOPLASTIC MEMBRANE ROOF SYSTEM

PVC: PVC MEMBRANE ROOF SYSTEM

S: SLURRY

REMARKS:

1. ALTERNATE 1 RE: NOMENCLATURE B

ROOF LEGEND

ROOF AREA INFORMATION

NEW NOMENCLATURE

(N) FULLY ADHERED 80 MIL PVC MEMBRANE

(N) FULLY ADHERED 1/2" HIGH DENSITY

COVER BOARD

(E) METAL DECK W/ LWIC SLURRY

(N) MECHANICALLY ATTACHED 2.2" ISO

(N) FULLY ADHERED 2.2" ISO

B BASE PROPOSALALTERNATE PROPOSAL

(N) FULLY ADHERED 80 MIL PVC MEMBRANE

(N) MECHANICALLY ATTACHED 1/2" HIGH

DENSITY COVER BOARD

(E) METAL DECK W/ LWIC SLURRY

(E) 4" EPS

(E) 2" LWIC

(E) TWO-PLY MOD.BIT. ROOF SYSTEM

A

EJ EJ EJ EJ EJ

E E E E E

PB

CD CD CD CD CD

W W W W

PLUMBING VENT

FLANGE VENT

PITCH PAN

EXISTING ROOF DRAIN

CURB MOUNTED VENT

CURB MOUNTED VENT

ABANDONED CURB TO

BE REMOVED/PATCHED

ABANDON EQUIP.

GOOSE NECK VENT

CURB MOUNTED A/C

SPLASH BLOCK

SPLASH PAN

A/C ON POSTS

ROOF HATCH

SCUPPER

GUTTER

DOWNSPOUT

WALL LADDER

PIPE BOX

WALK PAD

TAPERED INSULATION

RIDGE LINE

EXPANSION JOINT

GAS LINE

ELEC. LINE

COND. LINE

WATER LINE

PATH OF TRAVEL

PROPERTY LINE

EXTENTS OF WORK

EXISTING / N.I.C.

ROOF AREA

SLOPE INDICATOR

G G G G

SLOPE

PATH PATH PATH PATH PATH

PL PL PL PL PL

AutoCAD SHX Text A1

AutoCAD SHX Text

DS

AutoCAD SHX Text

SC

AutoCAD SHX Text G

AutoCAD SHX Text v

A/C

OFSC

OFSC

OFSC OFSC OFSC OFSC

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJEJEJEJEJEJEJEJEJ

EJ

EJ

EJ

O

FS

C O

FS

C

O

FS

C

NIC

NIC

NICNIC

A1

A2

B1

B2 C1

C2 A/C

A/C

EJ EJ EJ EJ EJ EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ EJ EJ

EJ

EJ

EJ EJ EJ EJ EJ EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

A/C

A/C

A/C

G

G

G

G

G G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

W W

W

W

W

W

W

W

W

W

W

W

W

W

W

G

G

G G

G

G v v

DS

DS

DS

DS

A/C

A/C

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

EJ

W W

W W

W W

W

W W

W W

W W

W

C D

C D

SLO

PE

SLO

PE

SLO

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SLOPE SLOPE

SLOPE SLOPE

SL

O

PE

SL

O

PE

A-1.1

KEY PLAN

CHECKED BY

DRAWN BY

DATE

PROJECT NUMBER

CLIENT

N

N

TRUE

NORTH

PLAN

NORTH

REVISIONS

DESCRIPTION DATENo.

M C

KI

N

N

EY

C

AM

PU

S

PH

AS

E

II

R E-

R O

O F

W U

N

IV

ER

SI

TY

D

R M

C

KI

N N

EY

, T

X

C O

LL

IN

C O

LL

EG

E

COLLIN COLLEGE

240361

05/02/2025

JH

CG

ISSUE FOR BID

BEAM Professionals 14001 Dallas Parkway

Suite 400 Dallas, TX 75240 972-233-1373 P BEAMProf.com

5-2-25

ENLARGED ROOF PLAN

1 ENLARGED ROOF PLAN

1/16" = 1'-0"

A

EJ EJ

E E

PB

CD CD

W W

PLUMBING VENT

FLANGE VENT

PITCH PAN

ROOF DRAIN

CURB MOUNTED VENT

CURB MOUNTED VENT

ABANDONED CURB TO

BE REMOVED/PATCHED

ABANDON EQUIP.

GOOSE NECK VENT

CURB MOUNTED A/C

SPLASH BLOCK

SPLASH PAN

A/C ON POSTS

ROOF HATCH

SCUPPER

GUTTER

DOWNSPOUT

WALL LADDER

PIPE BOX

WALK PAD

TAPERED INSULATION

RIDGE LINE

EXPANSION JOINT

GAS LINE

ELEC. LINE

COND. LINE

WATER LINE

PATH OF TRAVEL

PROPERTY LINE

EXTENTS OF WORK

EXISTING / N.I.C.

ROOF AREA

SLOPE INDICATOR

G G

SLOPE

PATH PATH

PL PL

ROOF LEGEND

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

1 PROVIDE NEW STAINLESS STEEL METAL AROUND COLUMNS, TYPICAL.

2 RAISE UNIT AS REQUIRED TO INSTALL CURB FLASH AND RESET UNIT ON EXISTING

NEWLY FLASHED CURB.

3 EXISTING PITCH PAN. REMOVE. INSTALL NEW LIQUID FLASHING AT EXISTING

PENETRATION.

4 EXISTING GAS LINE. DISCONNECT AND RECONNECT AS REQUIRED TO INSTALL NEW

CURB FLASHING AND NEW ROOF. TEXT / RECERTIFY GAS LINE AS REQUIRED BY STATE

OF TEXAS.

5 LIFT UNIT TO INSTALL NEW BASE FLASHINGS AT EXISTING CURB. SET UNIT BACK ONTO

NEWLY FLASHED EXISTING CURB. MAINTAIN EXISTING CURB CAP AND CURB ADAPTOR.

PROVIDE NEW OVERSIZED GROMMETED FASTENERS TO REATTACH METAL CURB CAP.

6 SUMP INSULATION LAYERS DOWN TO EXISTING DRAIN BOWL HEIGHT.

7 PROVIDE TEMPORARY SUPPORT FOR INSULATED LINES ON TRAPEZE HANGERS. ENSURE

THAT INSULATED LINES REMAIN OPERATIONAL AND UNDAMAGED DURING

CONSTRUCTION. PROVIDE PROTECTION PADS BENEATH ALL PIPE SUPPORTS, TYPICAL.

8 PROVIDE BLOCKING WITHIN SCUPPER ROUGH OPENING POST TEAR-OFF TO RAISE BASE

OF SCUPPER TO ACCOMMODATE NEW ROOF ELEVATION. REFLASH SCUPPER AND

PROVIDE NEW SCUPPER METAL TO MATCH EXISTING COLOR, TYPICAL.

9 REMOVE EXISTING COUNTERFLASHING TO INSTALL NEW ROOF MEMBRANE. INSTALL

NEW STAINLESS STEEL COUNTERFLASHING, TYPICAL.

10 PROVIDE NEW STAINLESS STEEL THYCURB CAPS, TYPICAL. DO NOT FASTEN INTO TOP

TYP. ALL

TYP. ALL

TYP. ALL

TYP. ALL

TYP. ALL

TYP. ALL

TYP. ALL

TYP. ALL

TYP. ALL

TYP. ALL

TYP. ALL

TYP. ALL

TYP. ALL

TYP. ALL

TYP. ALL

TYP. ALL

TYP. ALL

TYP. ALL

TYP. ALL

AutoCAD SHX Text A1

AutoCAD SHX Text

DS

AutoCAD SHX Text

SC

AutoCAD SHX Text

OF

AutoCAD SHX Text v

1 PROVIDE NEW STAINLESS STEEL METAL AROUND COLUMNS, TYPICAL.

2 RAISE UNIT AS REQUIRED TO INSTALL CURB FLASH AND RESET UNIT ON EXISTING

NEWLY FLASHED CURB.

3 EXISTING PITCH PAN. REMOVE. INSTALL NEW LIQUID FLASHING AT EXISTING

PENETRATION.

4 EXISTING GAS LINE. DISCONNECT AND RECONNECT AS REQUIRED TO INSTALL NEW

CURB FLASHING AND NEW ROOF. TEXT / RECERTIFY GAS LINE AS REQUIRED BY STATE

OF TEXAS.

5 LIFT UNIT TO INSTALL NEW BASE FLASHINGS AT EXISTING CURB. SET UNIT BACK ONTO

NEWLY FLASHED EXISTING CURB. MAINTAIN EXISTING CURB CAP AND CURB ADAPTOR.

PROVIDE NEW OVERSIZED GROMMETED FASTENERS TO REATTACH METAL CURB CAP.

6 SUMP INSULATION LAYERS DOWN TO EXISTING DRAIN BOWL HEIGHT.

7 PROVIDE TEMPORARY SUPPORT FOR INSULATED LINES ON TRAPEZE HANGERS. ENSURE

THAT INSULATED LINES REMAIN OPERATIONAL AND UNDAMAGED DURING

CONSTRUCTION. PROVIDE PROTECTION PADS BENEATH ALL PIPE SUPPORTS, TYPICAL.

8 PROVIDE BLOCKING WITHIN SCUPPER ROUGH OPENING POST TEAR-OFF TO RAISE BASE

OF SCUPPER TO ACCOMMODATE NEW ROOF ELEVATION. REFLASH SCUPPER AND

PROVIDE NEW SCUPPER METAL TO MATCH EXISTING COLOR, TYPICAL.

9 REMOVE EXISTING COUNTERFLASHING TO INSTALL NEW ROOF MEMBRANE. INSTALL

NEW STAINLESS STEEL COUNTERFLASHING, TYPICAL.

10 PROVIDE NEW STAINLESS STEEL THYCURB CAPS, TYPICAL. DO NOT FASTEN INTO TOP

CHECKED BY

DRAWN BY

DATE

PROJECT NUMBER

CLIENT

N

N

TRUE

NORTH

PLAN

NORTH

REVISIONS

DESCRIPTION DATENo.

M C

KI

N

N

EY

C

AM

PU

S

PH

AS

E

II

R E-

R O

O F

W U

N

IV

ER

SI

TY

D

R M

C

KI

N N

EY

, T

X

C O

LL

IN

C O

LL

EG

E

COLLIN COLLEGE

240361

05/02/2025

JH

CG

ISSUE FOR BID

BEAM Professionals 14001 Dallas Parkway

Suite 400 Dallas, TX 75240 972-233-1373 P BEAMProf.com

5-2-25

NEW SEALANT AND EIFS

REPAIR SCOPE EXTENTS

A-1.21 OVERALL BUILDING - SEALANT SCOPE

1/32" = 1'-0"

AREA

APROX. SQ.

FT. EXISTING NOMENCLATURE

NEW

NOMENCLATURE REMARKS

A1 1000 MTLD/ 1/8" S/ 4" EPS/ 2" LWIC/ MB A 1

A2 1000 MTLD/ 1/8" S/ 4" EPS/ 2" LWIC/ MB A 1

B1 6050 MTLD/ 1/8" S/ 4" EPS/ 2" LWIC/ MB A 1

B2 13860 MTLD/ 1/8" S/ 4" EPS/ 2" LWIC/ MB A 1

C1 1200 BUR-G A 1

C2 1200 BUR-G A 1

TOTAL 24310

NOTE: SQUARE FOOTAGES SHOWN ARE FOR REFERENCE ONLY - (FIELD VERIFY)

CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING CONDITIONS AND FOR

ENSURING NEW CONDITIONS ADHERE TO ALL LOCAL AND FEDERAL CODES ALONG WITH

INDUSTRY STANDARD GUIDELINES AND REMAIN IN A WATERTIGHT CONDITION.

ABBREVIATIONS:

ISO: ISO BOARD INSULATION

EPS: EXTRUDED POLYSTYRENE INSULATION BOARD

LWIC: LIGHT WEIGHT INSULATING CONCRETE

MTLD: METAL DECK

BUR-G: MULTI-PLY COAL TAR BUILT-UP ROOF SYSTEM W/GRAVEL

MB: 2 PLY MODIFIED BITUMEN ROOF SYSTEM

TPO: THERMOPLASTIC MEMBRANE ROOF SYSTEM

PVC: PVC MEMBRANE ROOF SYSTEM

S: SLURRY

REMARKS:

1. ALTERNATE 1 RE: NOMENCLATURE B

ROOF LEGEND

ROOF AREA INFORMATION

A

PB

PLUMBING VENT

FLANGE VENT

PITCH PAN

EXISTING ROOF DRAIN

CURB MOUNTED VENT

CURB MOUNTED VENT

ABANDONED CURB TO

BE REMOVED/PATCHED

ABANDON EQUIP.

GOOSE NECK VENT

CURB MOUNTED A/C

SPLASH BLOCK

SPLASH PAN

A/C ON POSTS

ROOF HATCH

SCUPPER

GUTTER

DOWNSPOUT

WALL LADDER

PIPE BOX

WALK PAD

TAPERED INSULATION

RIDGE LINE

EXPANSION JOINT

GAS LINE

ELEC. LINE

COND. LINE

WATER LINE

PATH OF TRAVEL

PROPERTY LINE

EXTENTS OF WORK

EXISTING / N.I.C.

ROOF AREA

SLOPE INDICATORSLOPE

DASHED LINE DENOTES EXTENTS OF SEALANT JOINT

REPLACEMENT. CUT OUT SEALANT AND CLEAN ALL SOFT

JOINTS THROUGHOUT EXTENTS OF ENTIRE FACADE ON

THIS BUILDING. WORK STOPS AND STARTS AT THE

CONNECTION TO THE PARKING GARAGE. JOINTS TO BE

REMOVED AND REPLACED INCLUDE ALL CONTROL JOINTS,

EXPANSION JOINTS, AND SOFT JOINTS AROUND ALL

WINDOWS AND DOORS (HEAD, JAMB, SILL). SCOPE ALSO

INCLUDES MANY LOCATIONS WITHIN CAST STONE AND

MASONRY ELEMENTS LOCATED WITHIN THE NORTH

FACING FACADE OF THE 2010 ADDITION. SOFT JOINTS

ONLY. SCOPE TO ALSO INCLUDE ANY PENETRATIONS

THROUGH FACADE SUCH AS CONDUIT, UTILITY BOXES,

LIGHTS, ETC. SEAL TOP AND SIDES OF ALL SUCH

PENETRATIONS / FIXTURES ON BUILDING.

CONTRACTOR TO PROVIDE PRICING FOR REMOVAL AND

NEW SEALANT JOINTS WITH SILICONE AS WELL AS AN

ALTERNATE PRICE FOR POLYURETHANE SEALANT.

COLOR TO MATCH EXISTING IN EACH APPLICATION.

INFILL ALL HOLES / CRACKS / DAMAGE OF EXISTING EIFS

SYSTEM WITH NEW FOAM AS SHOWN BY 'X' TYPE DASHED

LINE INDICATING EXTENTS. EXTENTS ARE INTENDED TO

REPRESENT THE ENTIRE EIFS PROFILE THROUGHOUT THE

FACILITY. REMOVE ANY EXISTING CEMENTITIOUS BASE

COAT AND TOP COAT AS NEEDED TO REPAIR INSULATION

/ FOAM. SAND / CONTOUR APPROPRIATELY AS NEEDED

TO ACHIEVE ACCEPTABLE SUBSTRATE. PROVIDE NEW

CEMENTITIOUS BASE COATS AND TOP COATS WITH

REINFORCING MESH AT ALL LOCATIONS OF DAMAGE /

DETERIORATION OF EIFS SYSTEM. PROVIDE ACRYLIC

ELASTOMERIC COATING THROUGHOUT THE ENTIRETY OF

THE EIFS SYSTEM TO MATCH EXISTING COLOR AND

TEXTURE, OR COLOR AS SELECTED BY OWNER. SEAL

EIFS AT ALL TRANSITIONS TO DIFFERING SUBSTRATES /

CLADDING MATERIALS WITH COMPATIBLE SEALANT

PRODUCT. SEAL ALL LOCATIONS OF CONTROL JOINTS OR

EXPANSION JOINTS WITHIN EIFS. REMOVE EXISTING

PREFINISHED METAL COPING CAP AS NEEDED TO REPAIR

AND RECOAT EIFS SYSTEM. REINSTALL EXISTING COPING,

ENSURE SEAMS ARE MAINTAINED SEALED. USE NEW

OVERSIZED GROMMETED FASTENERS WHEN RESECURING

EXISTING PREFINISHED METAL COPING.

AutoCAD SHX Text A1

AutoCAD SHX Text

DS

AutoCAD SHX Text

SC

AutoCAD SHX Text G

AutoCAD SHX Text v

PLUMBING VENT STACK

SEALANT

DRAWBAND

INSTALL SEALANT BETWEEN

PIPE AND PREFABRICATED

MEMBRANE FLASHING

PREFABRICATED

MEMBRANE FLASHING

SEALANT (IF REQUIRED BY

THE SPECIFIC SYSTEM)

THERMOPLASTIC ROOF

MEMBRANE

ROOF SYSTEM (RE: SPECS)

PIPE PENETRATION

NOT TO SCALE

SCUPPER FLASHING

NOT TO SCALE

NOTES: UNIVERSAL SINGLE-PLY SEALANT IS REQUIRED AT FLASHING EDGES ON

SCUPPER EDGE. WHEN USING TPO MEMBRANE, TPO PRIME MUST BE USED TO

PREPARE SURFACES PRIOR TO THE APPLICATION OF SEALANT.

WATER CUT-OFF MASTIC, MUST BE

UNDER CONSTANT COMPRESSION

WOOD NAILER, INSTALL TO SECURE

METAL SLEEVE

HOT AIR WELD 1-1/2" MIN.

SEALANT

WATER CUT-OFF MASTIC

APPLICABLE BONDING ADHESIVE

THERMOPLASTIC NON-REINFORCED

FLASHING, 2" MIN. COVERAGE PAST

NAIL HEAD

SEALANT

THERMOPLASTIC

COATED SHEET

METAL SCUPPER

THERMOPLASTIC ROOF MEMBRANE

PLAN VIEW

1/2:12

1/2:12

1/2:12

ROOF DRAIN SUMP DETAIL

NOT TO SCALE

INSULATION TO MATCH ELEVATION

OF FIELD INSULATION

TAPER INSULATION

ROOF DRAIN (SUMP MIN. 1")

OVERFLOW DRAIN, W/ 2" COLLAR TO

BE INSTALLED 4'-0" UP SLOPE FROM

PRIMARY ROOF DRAIN

2'-0"2'-0"

THERMOPLASTIC

ROOF MEMBRANE

ROOF DECK

RECOVERY BOARD

1/2":12 TAPER INSULATION

ROOF DECK

CLAMPING RING

DECK CLAMP

DRAIN BOWL ROUND CUT IN

THERMOPLASTIC MEMBRANE; EXTEND

APPROX. 1" PAST CLAMPING RING

HOLE IN MEMBRANE SHOULD BE LARGER

THAN DRAIN PIPE DIAMETER

INSTALL WATER BLOCK BETWEEN DRAIN BOWL FLANGE

AND ROOF MEMBRANE

ROOF DRAIN

NOT TO SCALE

DRAIN STRAINER

SEAL NEW MEMBRANE FLASHING TO WALL &

EXISTING DAMP PROOFING

WATERPROOF FLASHING MEMBRANE

REMOVE/DEMO (E) SUBSTRATE (3 COURSES

HIGH) & THRU WALL FLASHING - COMPLETE.

PATCH TO MATCH EXISTING.

WEEP @ 24" O.C. W/ MORTAR NET PACKING

REMOVABLE S.S THRU WALL RECEIVER

SECURE TO BACK UP WALL & SEAL W/ THREE

COURSING.

REMOVABLE COUNTER FLASHING

ANCHORED 8" O.C. W/ WIND CLIPS @ 3' O.C.

HOT AIR WELD SINGLE PLY

FLASHING MEMBRANE

SHEET METAL EXPANSION JOINT COVER

THERMOPLASTIC ROOF MEMBRANE

(E) BACKUP WALL

8" M

IN

E THRU- WALL FLASHING @ EJ

NOT TO SCALE

(E) FACE BRICK

ROOF DECK

EQUIPMENT CURB

NOT TO SCALE

BASE OF UNIT EXTENDS 1/2" MIN.

BEYOND TOP OF CURB

CONT. SEALING MATERIAL @ TOP

OF CURB (RE: SPEC'S)

1" MIN. BELOW TOP OF CURB

TERM. BAR W/ NEOPRENE

WASHER FASTENED 12" O.C.

SET IN SEALANT

SEALING MATERIAL

CURB

HIGH - DOMED S.S., CAPPED,

GASKETED FASTENERS

18" O.C. - MIN. TWO EA. SIDE

REMOVABLE SHEET METAL

COUNTERFLASHING

S.S FASTENERS APPROX.

8" O.C.

FLASING MEMBRANE

ADHERE TO CURB

HEAT WELD (REFER TO

MANUFACTURER

SPECIFICATIONS)

THERMOPLASTIC ROOF

MEMBRANE

ROOF DECK

REMOVABLE COUNTERFLASHING

CONTINUOUS SEALANT

NOMINAL

CURB

HEIGHT

10" MIN.

MECH. UNIT,

HOOD, ETC.

S.S. COVER W/ RECEIVER

FOR COUNTER FLASH

HIGH-DOMED, CAPPED,

GASKETED FASTENERS

18" O.C. - MIN. TWO EA. SIDE

FASTENERS AT 8" O.C.

REMOVABLE COUNTER

FLASHING FASTENED 8" O.C.

BASE FLASHING

TAPERED EDGE WHERE APP.

SPECIFIED ROOF SYSTEM

CURBROOF DECK

NEOPRENE

ISOLATION PAD

EXISTING UNISTRUT

18 GA. S.S. STRAPS 12" O.C.

EQUIPMENT SUPPORT CURB

NOT TO SCALE

10"

NOMINAL

FLASHING

HEIGHT

12" MINOR 45°

HOODED CURB

NOT TO SCALE

FACE CLOSURE

FASTENERS APROX. 8" O.C.

SLOPE PIPES DOWN AND

AWAY FROM HOOD

REMOVEABLE SHEET

METAL COUNTERFLASHING

HIGH-DOMED SS, CAPPED, GASKETED

FASTENERS APPROX. 18" O.C. DEPENDING

UPON WIND ZONE AND CONDITIONS; MIN.

TWO FASTENERS PER SIDE)

INSULATE VOID

TO PREVENT

CONDENSATION

S.S. HOOD / COVER

CROSS BREAK OF

SLOPE FOR DRAINAGE

WOOD CANT TO

BRACE CURB

WOOD NAILERS

AND CURB

MIN. 4" CLEARANCE FROM PIPE TO TOP OF CURB;

MIN 2" BETWEEN PIPES

ROOF DECK

RE: SPECS

4"

MIN.

4"

MIN.

6"

MIN.

SINGLE PENETRATION

COMPLETED ASSEMBLY

MULTIPLE PENETRATIONS

PIPE PENTRATION

MEMBRANE COATED

METAL PITCH PAN

ROOF CEMENT

HOT AIR WELDED

FLASHING MEMBRANE

APPROX. 4" BEYOND

FLANGE

QUICK SETTING GROUT

POURABLE SEALER

ELASTOMERIC SEALANT &

STAINLESS STEEL DRAW BAND

SHEET METAL HOOD & FACE COVER

SCREWS & SEALING WASHERS

PIPES (FORM DOWNWARD

LOOP AWAY FROM HOOD)

S.S. METAL UMBRELLA

FLASHING

ROOF SYSTEM

PITCH PAN

NOT TO SCALE

ROOF DETAILS

A-2

KEY PLAN

CHECKED BY

DRAWN BY

DATE

PROJECT NUMBER

CLIENT

N

N

TRUE

NORTH

PLAN

NORTH

REVISIONS

DESCRIPTION DATENo.

M C

KI

N

N

EY

C

AM

PU

S

PH

AS

E

II

R E-

R O

O F

W U

N

IV

ER

SI

TY

D

R M

C

KI

N N

EY

, T

X

C O

LL

IN

C O

LL

EG

E

COLLIN COLLEGE

240361

05/02/2025

JH

CG

ISSUE FOR BID

BEAM Professionals 14001 Dallas Parkway

Suite 400 Dallas, TX 75240 972-233-1373 P BEAMProf.com

5-2-25

20 19 18 17

15 14 13 12 11

10 9 8 7 6

5 4 3 2 1

CONTINUOUS THROUGH-WALL

FLASHING TURN BAR AND 3-COURSE

TOOLED POLYURETHANE SEALANT

SHEET METAL REGLET FASTEN

VERTICAL LEG AND 3-COURSE

FASTENERS 24" O.C.

3" LAP WITH BEAD OF SEALANT

3" LAP AT JOINTS

2" WIDE CLIP APPROX. 30" O.C.

REMOVABLE SHEET METAL

COUNTER FLASHING

TERMINATION BAR FASTENED

APPROX. 12" O.C.

INSTALL SEALANT BEHIND MEMBRANE

CONTINUOUS SEALANT

CONTINUOUS THROUGH WALL

FLASHING OVER ROOF MEMBRANE

UNDER TERMINATION BAR

FLASHING MEMBRANE

HOT AIR WELD SINGLE PLY

THERMOPLASTIC ROOF MEMBRANE

WOOD NAILERS

ROOF DECK RE: SPECS

BASE FLASHING

NOT TO SCALE

ROOF SYSTEM

BASE W/ WALL PANEL

NOT TO SCALE

METAL WALL PANEL

SECURE AND SEAL METAL RECEIVER TO

SHEATHING BOARD

S.S. RECEIVER / REMOVABLE COUNTER

FLASHING W/ WIND CLIPS @ 3' O.C.

TERMINATION BAR FASTENED APPROX. 12" O.C.

INSTALL SEALANT BEHIND MEMBRANE

THERMOPLASTIC ROOF MEMBRANE

CONTINUOUS SEALANT

3/4" PLYWOOD SECURE TO SHEATHING BOARD

DAMPROOFING

(E) BACK UP

HOT AIR WELD SINGLE PLY

8" M

IN

E THRU-WALL FLASHING @ EJ W/ ROD

NOT TO SCALE

SEAL NEW MEMBRANE FLASHING TO WALL &

EXISTING DAMP PROOFING

WATERPROOF FLASHING MEMBRANE

REMOVE/DEMO (E) SUBSTRATE (3 COURSES

HIGH) & THRU WALL FLASHING - COMPLETE.

PATCH TO MATCH EXISTING.

WEEPS @ 24" O.C. W/ MORTAR NET PACKING

REMOVABLE STAINLESS STEEL THRU WALL

RECEIVER SECURE TO BACK UP WALL & SEAL W/

THREE COURSING.

REMOVABLE COUNTER FLASHING

ANCHORED 8" O.C. W/ WIND CLIPS @ 3' O.C.

HOT AIR WELD SINGLE PLY

(E) BACKUP

WALL

INSTALL SEALANT BEHIND MEMBRANE

TERMINATION BAR FASTENED APPROX. 12" O.C.

FLEXIBLE FOAM ROD; MIN. DIAMETER

1 1/2 TIMES WIDTH OF OPENING

FLEXIBLE VAPOR RETARDER

W/ COMPRESSIBLE INSULATION.

2Xs TO MATCH NEW ROOF ELEVATION

SEAL NEW MEMBRANE FLASHING TO WALL &

EXISTING DAMP PROOFING

WATERPROOF FLASHING MEMBRANE

REMOVE/DEMO EXIST. BRICK (3 COURSES HIGH) &

THRU WALL FLASHING - COMPLETE. PATCH BRICK

TO MATCH EXISTING.

WEEPS @ 24" O.C. W/ MORTAR NET PACKING

REMOVABLE S.S. THRU WALL RECEIVER SECURE

TO BACK UP WALL & SEAL W/ THREE COURSING.

REMOVABLE COUNTER FLASHING

ANCHORED 8" O.C. W/ WIND CLIPS @ 3' O.C.

TERMINATION BAR FASTENED APPROX. 12" O.C.

INSTALL SEALANT BEHINDMEMBRANE

CONTINUOUS SEALANT

THERMOPLASTIC

ROOF MEMBRANE

8" M

IN

E THRU- WALL FLASHING

NOT TO SCALE

ROOF DECK

HOT AIR WELD SINGLE PLY

1/2"

4-1/2"

1/2"

FASTENER DISC PLATE

THERMOPLASTIC

MEMBRANE

APPROVED FASTENER

EXISTING DECK TO REMAIN

REPLACE AS REQUIRED

1-1/2" MIN. HOT

AIR WELD LAP

SILICONE ROLLING

TOOL

1-1/2" FIELD WELD

(MINIMUM)

MEMBRANE LAP

NOT TO SCALE

HOT AIR

WELDER

NOTE: WHEN FASTENING INSULATION OR SLIP SHEETS, INSTALL FASTENERS FLUSH

WITH TOP SURFACE OF THE INSULATION BEING CAREFUL NOT TO BREAK THE FACER

OR CRUSH THE INSULATION.

VARIES

APPROX.

1/2" GAP

12' MAX LENGTH

EACH PIECE

OF PARAPET CAP

1" M

IN

. B

EL

O

W B

LO

C

KI

N

G

PARAPET & CAP

NOT TO SCALE

SHEET METAL JOINT COVER

PLATE 6" WIDE MIN. SET IN

TWO BEADS OF SEALANT

SHEET METAL PARAPET CAP

HIGH-DOMED, CAPPED,GASKETED

FASTENERS (APPROX. 18" O.C.

DEPENDING UPON WIND ZONE

AND LOCAL CONDITIONS)

FASTENERS APPROX. 6" O.C.

EXTEND MEMBRANE TO BELOW

NAILER AND SECURE

CONTINUOUS TAPERED WOOD

SHIM (E.G. BEVELED CEDAR SIDING)

WOOD NAILER

FLASHING MEMBRANE (ADHERED

TO WALL)

SEALANT (IF REQUIRED BY THE

SPECIFIED SYSTEM)

THERMOPLASTIC ROOF MEMBRANE

ROOF SYSTEM

ROOF DECK

HOT AIR WELD SINGLE PLY

GAS PIPE SUPPORTS

LINES LESS THAN 3" O.D.

ELECTRICAL CONDUIT/ CONDENSATE LINES

LINES LESS THAN 3" O.D.

LARGER LINE SUPPORTS

LINES 3" O.D. OR LARGER

GAS LINES USE

ROLLER CLEVIS

TACK SUPPORTS TO PAD

WITH APPROVED MASTIC OR ADHESIVE

SUPPORT BASE MIN 10" X 16" X 3"

ROLLER HANGER W/ HOLD DOWN CLIPS

ROOF MANUFACTURE APPROVED

PROTECTIVE TRAFFIC PAD

TACK SUPPORTS TO PAD

WITH APPROVED MASTIC

OR ADHESIVE

SUPPORT BASE MIN 10"X16"X3"

STRUT W/ HOLD DOWN CLIPS

ROOF MANUFACTURE APPROVED

PROTECTIVE TRAFFIC PAD

12 GA SLOTTED

STRUT HEADER BAR

12 GA. SLOTTED

STRUT SUPPORT

LEGS

NOTE: NON - PENETRATING PIPE SUPPORTS MAX 8'-0" O.C. INCLUDING (BETWEEN

SEISMIC SUPPORTS) AND 2'-0" FROM CHANGE OF DIRETION OR ELEVATION.

NOT TO SCALE

NON - PENETRATING PIPE SUPPORTS

AutoCAD SHX Text

XXXXXX

XXXXXX

DRAWN BY

DATE

PROJECT NUMBER

CLIENT

N

N

TRUE

NORTH

PLAN

NORTH

REVISIONS

DESCRIPTION DATENo.

M C

KI

N

N

EY

C

AM

PU

S

PH

AS

E

II

R E-

R O

O F

W U

N

IV

ER

SI

TY

D

R M

C

KI

N N

EY

, T

X

C O

LL

IN

C O

LL

EG

E

COLLIN COLLEGE

240361

05/02/2025

JH

CG

ISSUE FOR BID

BEAM Professionals 14001 Dallas Parkway

Suite 400 Dallas, TX 75240 972-233-1373 P BEAMProf.com

5-2-25

SEALANT SCOPE

PHOTOGRAPHS

A-3

20 19 18 17 16

15 14 13 12 11

10 9 8 7 6

5 4 3 2 1 PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

REMOVE EXISTING SEALANT AT WINDOW SYSTEM

HEAD, JAMB, AND SILL AND PROVIDE NEW BACKER

ROD AND SEALANT

REMOVE EXISTING SEALANT AT ALL CONTROL JOINTS

AND MATERIAL TRANSITIONS AND PROVIDE NEW

BACKER ROD AND SEALANT, TYPICAL.

REMOVE EXISTING SEALANT AT WINDOW SYSTEM

HEAD, JAMB, AND SILL AND PROVIDE NEW BACKER

ROD AND SEALANT

REMOVE EXISTING SEALANT AT WINDOW SYSTEM

HEAD, JAMB, AND SILL AND PROVIDE NEW BACKER

ROD AND SEALANT

REMOVE EXISTING SEALANT AT WINDOW SYSTEM

HEAD, JAMB, AND SILL AND PROVIDE NEW BACKER ROD AND SEALANT.

REMOVE SOFT JOINTS AT CONTROL JOINTS AND MATERIAL

TRANSITIONS AND PROVIDE NEW BACKER ROD AND SEALANT, TYP.

REMOVE EXISTING SEALANT AT WINDOW SYSTEM

HEAD, JAMB, AND SILL AND PROVIDE NEW BACKER

ROD AND SEALANT ALL THE WAY AROUND BUILDING, TYP.

REMOVE EXISTING

SEALANT AT

WINDOW SYSTEM

HEAD, JAMB, AND

SILL AND PROVIDE

NEW BACKER

ROD AND SEALANT.

REMOVE SEALANT

AT CONTROL JOINTS

AND SOFT JOINTS

WITHIN MASONRY

AND PROVIDE NEW

BACKER ROD AND

SEALANT, TYPICAL

REMOVE

EXISTING

SEALANT AT

CAST STONE

JOINT AND

PROVIDE NEW

BACKER

ROD AND

SEALANT

REMOVE EXISTING SEALANT AT WINDOW SYSTEM

HEAD, JAMB, AND SILL AND PROVIDE NEW BACKER

ROD AND SEALANT. REMOVE SEALANT AT SOFT JOINTS

WITHIN MASONRY AND STONE AND PROVIDE NEW BACKER ROD AND SEALANT

REMOVE EXISTING

SEALANT AT

WINDOW SYSTEM

HEAD, JAMB, AND

SILL AND PROVIDE

NEW BACKER

ROD AND SEALANT.

REMOVE SEALANT

AT CONTROL JOINTS

AND SOFT JOINTS

WITHIN MASONRY

AND PROVIDE NEW

BACKER ROD AND

SEALANT, TYPICAL

REMOVE EXISTING

SEALANT AT

WINDOW SYSTEM

HEAD, JAMB, AND

SILL AND PROVIDE

NEW BACKER

ROD AND SEALANT.

REMOVE SEALANT

AT CONTROL JOINTS

AND SOFT JOINTS

WITHIN MASONRY

AND PROVIDE NEW

BACKER ROD AND

SEALANT, TYPICAL

REMOVE EXISTING SEALANT AT WINDOW SYSTEM

HEAD, JAMB, AND SILL AND PROVIDE NEW BACKER

ROD AND SEALANT ALL THE WAY AROUND BUILDING, AS

WELL AS AT WALL FIXTURES AND DOORS, TYPICAL

REMOVE EXISTING

SEALANT AT

CONTROL JOINTS

AND PROVIDE NEW

BACKER

ROD AND SEALANT.

REMOVE SEALANT

AT SOFT JOINTS

WITHIN MASONRY

AND PROVIDE NEW

BACKER ROD AND

SEALANT, TYPICAL

REMOVE EXISTING SEALANT AT WINDOW SYSTEM HEAD, JAMB, AND SILL

AND PROVIDE NEW BACKER ROD AND SEALANT. REMOVE SEALANT AT

CONTROL JOINTS AND SOFT JOINTS WITHIN MASONRY AND PROVIDE NEW

BACKER ROD AND SEALANT, TYPICAL

REMOVE EXISTING

SEALANT AT WINDOW

SYSTEM HEAD, JAMB,

AND SILL AND

PROVIDE NEW

BACKER ROD AND

SEALANT. REMOVE

SEALANT AT CONTROL

JOINTS AND SOFT

JOINTS WITHIN

MASONRY AND

PROVIDE NEW

BACKER ROD AND

SEALANT, TYPICAL

REMOVE EXISTING SEALANT AT WINDOW SYSTEM HEAD, JAMB, AND SILL

AND PROVIDE NEW BACKER ROD AND SEALANT. REMOVE SEALANT AT

CONTROL JOINTS AND SOFT JOINTS WITHIN MASONRY AND PROVIDE NEW

BACKER ROD AND SEALANT, TYPICAL, AS WELL AS AT FIXTURES.

REMOVE EXISTING SEALANT AT WINDOW SYSTEM HEAD, JAMB, AND SILL

AND PROVIDE NEW BACKER ROD AND SEALANT. REMOVE SEALANT AT

CONTROL JOINTS AND SOFT JOINTS WITHIN MASONRY AND PROVIDE NEW

BACKER ROD AND SEALANT, TYPICAL, AS WELL AS AT FIXTURES.

REMOVE EXISTING SEALANT AT WINDOW SYSTEM

HEAD, JAMB, AND SILL AND PROVIDE NEW BACKER

ROD AND SEALANT. REMOVE SEALANT AT SOFT JOINTS

WITHIN MASONRY AND STONE AND PROVIDE NEW BACKER ROD AND SEALANT

REMOVE EXISTING

SEALANT AT

CONTROL JOINTS

AND PROVIDE NEW

BACKER

ROD AND SEALANT.

REMOVE SEALANT

AT SOFT JOINTS

WITHIN MASONRY

AND PROVIDE NEW

BACKER ROD AND

SEALANT, TYPICAL

REMOVE EXISTING SEALANT AT CONTROL JOINTS AND PROVIDE NEW BACKER

ROD AND SEALANT. REMOVE SEALANT AT SOFT JOINTS WITHIN MASONRY

AND PROVIDE NEW BACKER ROD AND SEALANT, TYPICAL

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

DRAWN BY

DATE

PROJECT NUMBER

CLIENT

N

N

TRUE

NORTH

PLAN

NORTH

REVISIONS

DESCRIPTION DATENo.

M C

KI

N

N

EY

C

AM

PU

S

PH

AS

E

II

R E-

R O

O F

W U

N

IV

ER

SI

TY

D

R M

C

KI

N N

EY

, T

X

C O

LL

IN

C O

LL

EG

E

COLLIN COLLEGE

240361

05/02/2025

JH

CG

ISSUE FOR BID

BEAM Professionals 14001 Dallas Parkway

Suite 400 Dallas, TX 75240 972-233-1373 P BEAMProf.com

5-2-25

EIFS SCOPE

PHOTOGRAPHS

A-3.1

20 19 18 17 16

15 14 13 12 11

10 9 8 7 6

5 4 3 2 1 PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

PHOTOGRAPH

N.T.S.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

EIFS TO BE REPAIRED AND

RECOATED. REMOVE AND

REINSTALL EXISTING

PREFINISHED METAL

COPING AS REQUIRED TO

PERFORM EIFS REPAIR AND

RECOAT. ENSURE SEAL IS

MAINTAINED AT COPING

JOINTS. USE NEW

OVERSIZED GROMMETED

FASTENERS.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

EIFS TO BE REPAIRED AND

RECOATED. REMOVE AND

REINSTALL EXISTING

PREFINISHED METAL

COPING AS REQUIRED TO

PERFORM EIFS REPAIR AND

RECOAT. ENSURE SEAL IS

MAINTAINED AT COPING

JOINTS. USE NEW

OVERSIZED GROMMETED

FASTENERS.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

EIFS TO BE REPAIRED AND RECOATED. REMOVE AND REINSTALL

EXISTING PREFINISHED METAL COPING AS REQUIRED TO PERFORM

EIFS REPAIR AND RECOAT. ENSURE SEAL IS MAINTAINED AT COPING

JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

EIFS TO BE REPAIRED AND RECOATED WHERE BIRDS HAVE DUG INTO THE EIFS AND

NESTED. REMOVE BIRDS. REMOVE AND REINSTALL EXISTING PREFINISHED METAL

COPING AS REQUIRED TO PERFORM EIFS REPAIR AND RECOAT. ENSURE SEAL IS

MAINTAINED AT COPING JOINTS. USE NEW OVERSIZED GROMMETED FASTENERS.

NEWER BUILDING ADDITION IS STONE

COPING, NOT EIFS. NO EIFS SCOPE AT

NEWER BUILDING ADDTION.

Sheets and Views
COVERSHEET

File details come from the government source that posted it. Updated .