24-8237_Exhitit_M_Plans_Rev._1.pdf
PDF 10 MB Posted
- Attached to
- MARGOOD COTTAGES RESTORATION
- Solicitation number
- 24-8237
- Issued by
- Collier County, Gretna City, Florida
About this file
The document is a comprehensive set of architectural and engineering plans for the MarGood Cottages Restoration Project for Collier County Museums, located in Goodland, Florida. The project involves the restoration of three historic cottages (Cottages #1, #2, and #3) and the construction of a new outdoor classroom at MarGood Harbor Park. The scope of work includes demolishing Cottage #4, repairing and stabilizing cottage foundations, restoring exterior siding, replacing metal roofing, repairing windows and doors, installing new beadboard paneling, painting, and creating accessible ramps and concrete walkways. The restoration will follow the United States Secretary of Interior's Guidelines for Historic Restoration and National Park Service Preservation Standards.
The project plans are detailed across multiple sheets, including site plans, floor plans, elevations, sections, roof details, and electrical specifications. The restoration emphasizes preserving the historic character of the cottages while making them accessible and functional. The electrical plans include new panel systems, lighting circuits, and site lighting. Base bid work includes 50 linear feet of wood siding replacement and 20 linear feet of roof beam replacement, with options for additional work in Cottages #2 and #3. The project includes provisions for hazardous material abatement, including potential lead-based paint and asbestos-containing materials, with specific protocols for testing, removal, and disposal.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONSULTANTS
G100
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
RB
JS
TITLE SHEET
G O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
8/19/2024
N
N
G100 A000 A001 A002 A003 A100 A101 A102 A103 A200 A300 A301 A302 A303 A500 A501 A502
TITLE SHEET
ROOFING SCHEDULES & NOTES
EXISTING SITE PLAN
PROPOSED SITE PLAN
RESTROOM LOCATION PLAN
COTTAGE #1 FLOOR PLANS
COTTAGE #2 FLOOR PLANS
COTTAGE #3 AND OUTDOOR CLASSROOM PLANS
COTTAGE #3 FRAMING AND OUTDOOR CLASS. FOUNDATION...
EXTERIOR ELEVATIONS
SECTIONS
SECTIONS
SECTIONS
SECTIONS
TYPICAL ROOF PLAN & DETAILS
DETAILS
DETAILS
A502 E100 E101
DETAILS
ELECTRICAL NOTES
ELECTRICAL325 PEAR TREE AVE.
GOODLAND, FLORIDA 34140
DRAWING INDEX
MARGOOD COTTAGES RESTORATION
COLLIER COUNTY MUSEUMS
GOODLAND, FLORIDA
BUILDING AND FIRE CODESVICINITY MAP
AERIAL PHOTO
SCOPE OF WORK
BRIEFLY AND WITHOUT FORCE AND EFFECT UPON THE CONTRACT DOCUMENTS, THE WORK OF THE CONTRACT CAN BE
SUMMARIZED AS FOLLOWS:
THE RESTORATION OF THE HISTORIC MARGOOD COTTAGES, WORK INCLUDES DEMOLITION OF THE EXISTING COTTAGE NUMBER #4, REPAIRS/STABILIZATION TO ALL REMAINING COTTAGE FOUNDATIONS, REPAIR AND RESTORATION OF THE EXISTING DETERIORATED/MISSING SIDING, AND REPLACEMENT ALL OF THE EXISTING METAL ROOF WITH NEW FIVE 'V' CRIMP METAL ROOF SYSTEM. THE SCOPE ALSO INCLUDES, THE REPAIR AND RESTORATION OF ALL EXISTING WINDOWS AND DOORS, REGLAZING, REPAIRING AND PATCHING DRY ROT AND DETERIORATED WOOD OF FRAMES, SASHES, AND MUTINS.
PRIMING AND PAINTING, 2 COATS ALL EXTERIOR WOOD SIDING AND WINDOWS. THE SCOPE ALSO INCLUDES THE REMOVAL OF THE CONCRETE PORCH/LANDING IN COTTAGE NO. 1 TO BE REBUILT W/ NEW ADA ACCESSIBLE RAMP AND HANDRAILS.
ALSO, TO REMOVE ALL INTERIOR WOOD PANELING IN CEILING/WALLS AND INSTALL NEW BEADBOARD PANELING. PRIMING AND PAINTING, 2 COATS ALL INTERIOR WALLS, CEILINGS, WINDOWS, AND DOORS, INSTALLATION OF NEW DOOR HARDWARE, REPAIRING EXISTING CABINETRY, IN COTTAGE NO. 1. ALSO, REPAIR OF EXISTING HEART PINE FLOORING, BASE BOARD TRIM AND MOLDINGS, AND OTHER FINISHES, AS NEEDED FOR FLOORING REPAIRS. CONTRACTOR TO ALSO INCLUDE THE INSTALLATION OF NEW OUTDOOR PAVILION, CONCRETE SIDEWALKS AND LANDSCAPING, AS DETAILED.
FLORIDA BUILDING CODE (FBC), 8TH EDITION (2023)
FLORIDA ACCESSIBILITY CODE (FAC), 8TH EDITION (2023)
FLORIDA EXISTING BUILDING CODE (FBC-EB), 8TH EDITION (2023)
FLORIDA FIRE PREVENTION CODE (FFPC), 8TH EDITION (2023)
NATIONAL ELECTRICAL CODE (NEC), 2023 EDITION
ASCE STANDARD 7-10 (STRUCTURAL WIND LOAD CRITERIA)
NOTE: BUILDINGS BEING RESTORED SHALL BE CONSIDERED EXHIBITS AND ARE NOT SUBJECT OR STRIC COMPLIANCE
WITH FBC.
FLORIDA PRODUCT APPROVAL:
AS REQUIRED BY FLORIDA STATUTE 553.842 AND FLORIDA ADMINISTRATIVE CODE 9B-72, PROVIDE INFORMATION AND PRODUCT APPROVAL NUMBER(S) ON THE BUILDING COMPONENTS UTILIZED ON THE CONSTRUCTION PROJECT REQUIRING PERMITTING AFTER APRIL 1, 2004. REFER TO WWW.FLORIDABUILDING.ORG FOR MORE INFORMATION.
PER CHAPTER 119, FLORIDA STATE STATUES, ALL DRAWINGS AND SPECIFICATIONS CONTAINED HEREIN ARE CONFIDENTIAL.
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF MLD ARCHITECTS AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR THE USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THE
CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED.
ELECTRONIC DISTRIBUTION OF THESE DOCUMENTS IS NOT AUTHORIZED, UNLESS SPECIFICALLY APPROVED BY PROJECT
ARCHITECT IN WRITING.
DISCLAIMER
NATIONAL PARK SERVICE PRESERVATION BRIEFS
THIS IS A HISTORIC PROPERTY LISTED BY THE NATIONAL TRUST FOR HISTORIC PRESERVATION. ALL WORK TAKING PLACE ON THIS BUILDING SHALL BE IN ACCORDANCE WITH THE UNITED STATES SECRETARY OF INTERIOR’S GUIDELINES FOR HISTORIC RESTORATION AND THE NATIONAL PARK’S SERVICE PRESERVATION STANDARDS AND BRIEFS. ALL WORK IS EXPECTED TO BE HELD TO THE HIGHEST STANDARD OF CRAFTSMANSHIP AND SHALL EXCEED BEST PRACTICES AND INDUSTRY STANDARDS. ANY WORK NOT MEETING THIS HIGH EXPECTATION WILL BE REQUIRED TO BE REMOVED AND
REINSTALLED.
04 ROOFING FOR HISTORIC BUILDINGS
09 THE REPAIR OF HISTORIC WOODEN WINDOWS
10 EXTERIOR PAINT PROBLEMS ON HISTORIC WOODWORK
16 THE USE OF SUBSTITUTE MATERIALS ON HISTORIC BUILDING EXTERIORS
17 ARCHITECTURAL CHARACTER-IDENTIFYING THE VISUAL ASPECTS OF HISTORIC BUILDINGS AS AN AID TO PRESERVING
THEIR CHARACTER
18 REHABILITATING INTERIORS IN HISTORIC BUILDINGS-IDENTIFYING CHARACTER-DEFINING ELEMENTS
28 PAINTING HISTORIC INTERIORS
32 MAKING HISTORIC PROPERTIES ACCESSIBLE
39 HOLDING THE LINE: CONTROLLING UNWANTED MOISTURE IN HISTORIC BUILDINGS
44 THE USE OF AWNINGS ON HISTORIC BUILDINGS: REPAIR, REPLACEMENT AND NEW DESIGN
47 MAINTAINING THE EXTERIOR OF SMALL AND MEDIUM SIZE HISTORIC BUILDINGS
A000
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
ROOFING SCHEDULES
& NOTES
G O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
8/19/2024
A
B
C
EXISTING WOOD SIDING
EXISTING WOOD STUD FRAMING
EXISTING WOOD SIDING
EXISTING WOOD STUD FRAMING
NEW INTERIOR WOOD
BEADBOARD WALL COVERING
NEW NOVELTY COVE WOOD SIDING
NEW INTERIOR WOOD
BEADBOARD WALL COVERING
P.T. 4x4 WOOD POST FRAMING
P.T. 2X6 WOOD LUMBER W/ 1/2" SPACING
EXTEND WALL TO BELOW DECK
GENERAL NOTES WORK NOTES
AWNING:
CAREFULLY REMOVE EXISTING ASPHALT SHINGLES IN ENTRY AWNING DOWN TO THE EXISTING
DECK. INSTALL SYNTHETIC WATERPROOFING UNDERLAYMENT OVER ROOF DECKING. INSTALL
24” WIDE 5V CRIMP METAL ROOF PANELS WITH GROMMET/SELF SEALING PER
MANUFACTURER'S FASTENING RECOMMENDATIONS TO MEET FBC WIND UPLIFT
REQUIREMENTS INTO ROOF DECKING. INSTALL PREFINISHED EDGE METAL TRIM, AS DETAILED.
CONTRACTOR SHALL REPAIR ALL EXISTING WOOD BRACKETS, FASCIA, SOFFIT AND TRIM.
SCRAPING, SANDING, CAULKING JOINTS, PRIMING, AND PAINTING 2 COATS TO MATCH
EXISTING COLOR. CONTRACTOR TO SUPPLEMENT DRY ROTTED SIDING TO MATCH EXISTING
PROFILES, SIZE AND SPECIES.
SIDING REPAIR:
WHERE RESTROOMS WERE PREVIOUSLY REMOVED, INSTALL NEW WALL WHERE INDICATED.
INSTALL NEW SIDING AND TRIM TO MATCH ORIGINAL INSTALLATION AND CONFIGURATION
EVIDENT ELSEWHERE ON THE STRUCTURE. BACK PRIME ALL MATERIALS AND SEAL END CRAW.
SAND, CAULK, AND PREPARE SURFACES FOR PAINT.
NOTE: NO PAINT SAMPLING HAVE BEEN TESTED FOR LEAD. CONTRACTOR TO HAVE PAINT
INDEPENDENTLY TESTED. NOTIFY ARCHITECT AND OWNER RESULTS BEFORE PROCEEDING WITH
RESTORATION.
RESTORE ALL COTTAGES EXISTING NOVELTY COVE SIDING, TRIM, AND EXPOSED WOOD
DECKING (TO MATCH). SCRAPING, SANDING, CAULKING JOINTS, PRIMING, AND PAINTING 2
COATS TO MATCH EXISTING COLOR. CONTRACTOR TO SUPPLEMENT AND/OR REPLACE DRY
ROTTED SIDING AND WHERE EXISTING SIDING IS MISSING/DAMAGED, TO MATCH EXISTING
PROFILES, SIZE AND SPECIES. BACK PRIME NEW SIDING WITH PREMIUM OIL BASED PRIMER,
PRIOR TO INSTALLATION, SEAL ALL END GRAIN OF REPLACEMENT WOOD SIDING.
BASE BID TO INCLUDE 50 LF. FT. OF WOOD DETERIORATION REPLACEMENT OF EXISTING
SIDING. ADD/DEDUCT OF $_____/LF FOR ADDITIONAL WOOD DETERIORATION REPLACEMENT.
WINDOW AND DOOR RESTORATION:
NOTE: NO PAINT SAMPLING NOR GLAZING COMPOUND HAVE BEEN TESTED FOR LEAD AND/OR
ASBESTOS. CONTRACTOR TO INDEPENDENTLY PERFORM TEST. NOTIFY ARCHITECT AND
OWNER RESULTS BEFORE PROCEEDING RESTORATION.
A. CUT OUT, SCRAPE AND REMOVE ALL EXISTING PERIMETER GLAZING COMPOUND BETWEEN
GLASS AND WOOD MUTTONS AND SASH OF ALL EXTERIOR WINDOWS AND TRANSOMS
UNLESS NOTED OTHERWISE. IF DETECTED, COMPLY WITH ABATEMENT PROCEDURES FOR
ASBESTOS CONTAINING GLAZING COMPOUND.
B. REPLACE ALL SEVERELY DETERIORATED WINDOW AND DOOR COMPONENTS WITH NEW
COMPONENTS TO MATCH EXISTING. AT SMALL AREAS OF WOOD ROT, CONTRACTOR TO
REMOVE ALL LOOSE AND UNSALVAGEABLE WOOD TO SOUND SUBSTRATE. ALL SOFT BUT
SALVAGEABLE WOOD SHALL BE SATURATED WITH MINWAX WOOD HARDENER AND RESTORED
WITH MINWAX EPOXY WOOD FILLER TO MATCH EXISTING WOOD PROFILES.
C. CLEAN RABBET GROOVE OF WOOD WINDOW MUNTINS AND SASH OF ALL OLD GLAZING
COMPOUND AND PAINT TO BARE WOOD. SAND, SEAL WITH LINSEED OIL AND PRIME WITH OIL
BASED PRIMER. REPLACE ALL BROKEN GLASS WITH NEW HISTORIC GLASS TO MATCH
EXISTING, SECURE NEW AND EXISTING GLASS WITH PUSH POINTS.
D. MILDEW PREVENTIVE (M-1) TO BE ADDED TO LINSEED OIL, GLAZING COMPOUND, PRIMERS
AND PAINT.
E. REGLAZE ALL WOOD EXTERIOR WINDOWS, CONTRACTOR TO CLEAN AND PREPARE, PRIME
AND GLAZE WOOD WINDOW FOR APPROVAL TO BE BASIS FOR QUALITY CONTROL.
F. PRIME (OIL BASED PRIMER) AND PAINT 2 COATS OVER GLAZING COMPOUND AT ALL
EXTERIOR WINDOWS. CLEAN, PRIME, AND PAINT EXTERIOR AND INTERIOR OF WINDOWS AND
CASING WITH PREMIUM PAINT/COATING SYSTEM.
APLLY FROSTED GLASS FILM ON INTERIOR OF WINDOW GLASS IN COTTAGES # 2,3.
RENOVATE ALL EXTERIOR DOORS, WINDOWS AND SHUTTERS, INCLUDING FRAMING, JAMBS,
GLAZING, STOOL, TRIMS, CASING, AND HARDWARE BY HAND CLEANING, REMOVING ALL
LOOSE, CRACKING, PEELING PAINT AND ALL GLAZING, REWORKING AND GLUING WOOD PARTS
AND REGLAZING WITH ORIGINAL GLASS. REPLACE BROKEN GLASS WITH FLOAT GLASS TO
MATCH. PRIME AND PAINT 2 COATS ALL SURFACES.
PAINTING:
SCRAPE LOOSE PAINT FROM ALL EXTERIOR COTTAGES AND PREPARE SUBSTRATE, FOR
PRIMING FOLLOWING PAINT.
MISCELLANEOUS METAL ACCESSORIES SUCH AS EXPOSED CONDUIT, UNLESS NOTED
OTHERWISE, ARE TO BE CLEANED, PRIMED AND PAINTED. ALL RUST TO BE MECHANICALLY OR
HAND ABRADED AND REPAIR RUSTED AREAS WITH FILLER WHERE NECESSARY, THOROUGHLY
CLEANED AS SPECIFIED. TOUCH UP PRIME BARE AND RUSTED METAL SURFACES, THEN
COMPLETELY PRIME AND PAINT (2) COATS OF PREMIUM INDUSTRIAL ACRYLIC PAINT ON ALL
PREVIOUSLY PAINTED EXTERIOR METAL SURFACES UNLESS NOTED OTHERWISE.
APPLY PRIMER/BOND COAT AND 2 COATS ACRYLIC PAINT COATING SYSTEM TO CLEANED AND
PREPARED, PREVIOUSLY PAINTED SIDING, NEW MASONRY SURFACES, HORIZONTAL BANDS,
REVEALS, COLUMNS, GABLE END WALLS OVER EXTERIOR OF BUILDING IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS UNLESS NOTED OTHERWISE.
APPLY PRIMER/BOND COAT AND 2 COATS PREMIUM EXTERIOR ACRYLIC COATING TO MATCH
EXISTING. PRIME SURFACES AS REQUIRED BY COATING MANUFACTURER AND PROVIDE
WRITTEN APPROVAL OF SUBSTRATE (AND PREPARATION) FROM COATING MANUFACTURER.
FINAL COLOR SHALL BE SELECTED/APPROVED BY ARCHITECT AND OWNER FROM PAINTED
SAMPLE PANEL AREA. COLORS TO BE SIMILAR TO, OR MATCH EXISTING.
PREVIOUSLY PAINTED WINDOW FRAMES TO BE CLEANED PERIMETER SEALANT BONDFACE.
CLEAN, PRIME, AND PAINT WINDOW FRAMES FOLLOWING SEALANT WORK AS SPECIFIED.
COTTAGE #1:
REMOVE EXISTING CONCRETE STAIRS AND PORCH/LANDING, AND HANDRAILS AT ENTRYWAYS
OF COTTAGE NO. #1. PATCH HOLES ON SIDING. CONTRACTOR TO BUILT NEW 5’X5’
CONCRETE STAIRS, AND NEW LANDINGS AT TOP AND BOTTOM OF STAIR. INSTALL NEW
STAINLESS-STEEL TUBULAR HANDRAILS MOUNTED AT 36" MAX. HEIGHT.
INSTALL NEW PRESSURE TREATED ADA ACCESSIBLE WOOD RAMP W/ 2" STAINLESS-STEEL
TUBULAR HANDRAILS 36" MAX. HEIGHT, AS DETAILED. INSTALL 6X6 P.T. WOOD POST WITH 3’
MIN. EMBEDMENT IN CONCRETE FOOTING USING (4) #5 BARS THRU POST @ 8” O.C. INSTALL
(2) 2X8 P.T. WOOD STRINGERS @ 16” O.C. RAMP SLOPE TO BE MINIMUM 1:12.
PROVIDE A LEVEL CONCRETE 5' X 5' LANDING AT BOTTOM OF RAMP, AS DETAILED.
INSTALL UV RESISTANT FILM ON INTERIOR OF ALL GLASS WINDOWS. (BASIS OF DESIGN:
LLUMAR FILM)
WORK NOTES CONTINUED
1. THIS IS A HISTORIC PROPERTY LISTED BY THE NATIONAL TRUST FOR HISTORIC
PRESERVATION. ALL WORK TAKING PLACE ON THIS BUILDING SHALL BE IN ACCORDANCE
WITH THE UNITED STATES SECRETARY OF INTERIOR’S GUIDELINES FOR HISTORIC
RESTORATION AND THE NATIONAL PARK’S SERVICE PRESERVATION STANDARDS AND
BRIEFS. ALL WORK IS EXPECTED TO BE HELD TO THE HIGHEST STANDARD OF
CRAFTSMANSHIP AND SHALL EXCEED BEST PRACTICES AND INDUSTRY STANDARDS. ANY
WORK NOT MEETING THIS HIGH EXPECTATION WILL BE REQUIRED TO BE REMOVED AND
REINSTALLED.
2. THE EXISTING PLANS ARE FOR INFORMATIONAL PURPOSES ONLY. CONTRACTOR SHALL
FIELD VERIFY ALL DIMENSIONS AND ALL CONDITIONS. IF THE CONTRACTOR IS UNABLE TO
INTERPRET THE CONTRACT DOCUMENTS, HE IS RESPONSIBLE FOR REQUESTING
CLARIFICATION IN WRITING TO THE ARCHITECT. IF THE CONTRACTOR PROCEEDS WITH ANY
WORK BEFORE OBTAINING CLARIFICATION, HE SHALL BE HELD RESPONSIBLE FOR ALL
DEFICIENCIES ASSOCIATED THERE WITHIN.
3. BEFORE SUBMITTING FOR THE WORK, EACH BIDDER WILL BE HELD TO HAVE EXAMINED THE
PREMISES AND SATISFIED HIMSELF AS TO THE EXISTING CONDITIONS UNDER WHICH HE
WILL BE OBLIGED TO OPERATE AND COMPLETE THE WORK UNDER THIS CONTRACT. NO
ALLOWANCE WILL BE MADE SUBSEQUENTLY IN THIS CONNECTION ON BEHALF OF THE
CONTRACTOR FOR ANY ERROR OR NEGLIGENCE ON HIS PART.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING CLEAR EXIT WAYS. WHERE AN
EXIT MUST BE TEMPORARILY BLOCKED, CONTRACTOR SHALL PROVIDE THE REQUIRED
BARRICADE AND DIRECTIONAL SIGNS FOR TEMPORARY EXITING AND SAFETY.
5. CONTRACTOR SHALL ERECT AND MAINTAIN ALL REASONABLE SAFEGUARDS FOR SAFETY
AND HEALTH INCLUDING POSTING DANGER SIGNS AND OTHER WARNINGS AGAINST
HAZARDS, AS WELL AS POSTING APPLICABLE SAFETY REGULATIONS. CONTRACTOR SHALL
PROVIDE SAFETY PRECAUTIONS AND BARRICADES FOR PEDESTRIANS AT CONSTRUCTION,
VEHICLE ACCESS AND EGRESS LOCATIONS.
6. NORMAL OPERATIONS OF THE REMAINING FACILITY SHALL CONTINUE DURING DEMOLITION
AND CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE
AND SEQUENCE DEMOLITION AND CONSTRUCTION TO MINIMIZE INTERRUPTIONS TO
NORMAL OPERATIONS OF THE FACILITY.
7. ALL PROPOSED INTERRUPTIONS TO OPERATIONS AND EQUIPMENT SHALL BE REVIEWED
WITH AND APPROVED BY THE OWNER PRIOR TO STARTING SUCH WORK UNLESS
OTHERWISE APPROVED IN WRITING.
8. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE AND SEQUENCE
DEMOLITION AND CONSTRUCTION. THE CONTRACTOR SHALL SUBMIT A COMPLETELY
DETAILED CONSTRUCTION SCHEDULE AND PLAN PRIOR TO PRE-CONSTRUCTION
CONFERENCE.
9. CONTRACTOR SHALL BE RESTRICTED TO AREAS SPECIFIED BY OWNER FOR ON SITE
STORAGE OF CONSTRUCTION MATERIALS. COMPARTMENT TRAILERS OR SIMILAR
PROTECTIVE STORAGE FACILITIES MAY BE UTILIZED ON SITE TO SECURE ALL EQUIPMENT
AND ITEMS REMOVED DURING PROJECT WORK. THE CONTRACTOR IS RESPONSIBLE FOR
THE PROTECTION AND SECURITY OF ALL EQUIPMENT AND ITEMS REMOVED.
10. CONTRACTOR MAY UTILIZE AVAILABLE ELECTRICAL POWER AND WATER UTILITIES AT
PROJECT JOB SITE.
11. ALL WORK SHALL COMPLY WITH APPLICABLE OSHA AND E.P.A. REGULATIONS AND
GUIDELINES.
12. INSTALL WORK IN ACCORDANCE WITH THE CODES LISTED ON THE COVER SHEET. WHERE
CONFLICTS OCCUR BETWEEN CODES AND BETWEEN THE CONSTRUCTION DOCUMENTS
AND CODES, THE MOST RESTRICTIVE REQUIREMENTS SHALL GOVERN.
13. CONTRACTOR SHALL FURNISH "AS-BUILT" DRAWINGS TO THE ARCHITECT AT COMPLETION
OF THE CONSTRUCTION. CHANGES SHALL BE INDICATED CLEARLY BY MECHANICAL
DRAFTING METHODS.
14. CONTRACTOR SHALL MAINTAIN A CLEAN WORK PREMISES AT ALL TIMES AND SHALL CLEAN
CONSTRUCTION SITE OF ALL DEBRIS DAILY.
15. CONTRACTOR SHALL TAKE CARE NOT TO DAMAGE EXISTING SURFACES AND SHALL BE
RESPONSIBLE FOR RETURNING DAMAGED AREAS (MATERIALS, FINISHES, LANDSCAPE,
ETC.) TO THEIR ORIGINAL CONDITION. ALL DISTURBED AREAS OF SOIL TO BE SODDED.
ALL PLANTING REPLACEMENT TO BE GUARANTEED FOR ONE YEAR.
16. CONTRACTOR SHALL ERECT ALL SAFEGUARDS TO PROTECT AREAS ADJACENT TO BUILDING
SITES. INSTALL SILT FENCING AS REQUIRED TO CONTAIN CONSTRUCTION RUNOFF.
REMOVE DEBRIS FROM JOB SITE DAILY AND ADHERE TO ENVIRONMENTAL REGULATIONS.
17. ANY PROPOSED CHANGES TO WORK MUST BE APPROVED AND PROPERLY DIRECTED BY
THE ARCHITECT. ANY WORK DIRECTED, REQUESTED OR RECOMMENDED BY THE OWNER,
OWNER'S REPRESENTATIVE, INSPECTOR, ETC. SHALL BE SUBMITTED TO THE ARCHITECT
VIA R.F.I. AND APPROVED BY ARCHITECT. ONLY THE ARCHITECT & OWNER CAN STOP
WORK.
CAREFULLY REMOVE EXISTING DETERIORATED INTERIOR WALL COVERINGS (BEAD BOARD OR
PLYWOOD) NEAR THE FLOOR TO IDENTIFY THE CONDITION OF THE WALL FRAMING. REMOVE WALL COVERINGS AS NECESSARY TO EXPOSE THE EXTENT OF DETERIORATION. SHORE WALL IF NECESSARY.
REMOVE DETERIORATED PORTIONS OF BOTH VERTICAL AND HORIZONTAL WALL FRAMING MEMBERS THAT ARE NOT SALVAGEABLE AND SISTER BOTH SIDES PROPERLY WITH NEW PRESSURE TREATED MEMBER TO MATCH EXISTING DIMENSION. EXTEND SISTER 3’ BEYOND DETERIORATED PORTION OF FRAMING AND FASTEN TO SOUND PORTIONS OF EXISTING MEMBER IN A STAGGARD PATTERN EVERY 6” O.C. WITH 3” DECKING SCREWS. IF FRAMING MEMBER IS DETERIORATED OVER HALF ITS LENGTH, REMOVE ENTIRE MEMBER AND REPLACE WITH NEW PRESSURE TREATED MEMBER, TO MATCH EXISTING DIMENSION. TREAT ALL WALL CAVITIES, FRAMING, AND UNEXPOSED SURFACES WITH BORA-CARE PER
MANUFACTURER’S RECOMMENDATIONS. REINSTALL ALL SALVAGEABLE WALL COVERINGS (BEAD
BOARD) AND SUPPLEMENT WITH NEW (WHERE PLYWOOD WAS INSTALLED) TO MATCH EXISTING
HISTORIC INSTALLATION. SINK ALL EXPOSED NAIL HEADS. SAND, CLEAN, PREPARE, PRIME, AND PAINT INTERIOR WALLS, 2 COATS, COLOR TO BE CHOSEN BY OWNER AND ARCHITECT. THE CONTRACTOR SHALL INCLUDE A BASE BID OF 300 BDFT OF WALL FRAMING REPAIR/ SISTER/ REPLACEMENT.
INTERIOR:
ON INTERIOR, REMOVE EXISTING WOOD PANELING ON WALL, CEILINGS, INSTALL NEW
BEADBOARD WALLS, CEILINGS, AND VARIOUS. WHERE FACE NAILING IS NECESSARY, SINK
NAILHEADS BELOW SURFACE OF WOOD. INSTALL NEW TRIM IN MATCHING PROFILES WHERE
EXISTING TRIM IS MISSING/DAMAGED. CLEAN, CAULK, PRIME AND PAINT WOOD CEILINGS,
WALLS, TRIM, FRAMES, MOLDINGS, ETC. COLOR TO MATCH EXISTING COLOR AND SHEEN.
REMOVE AND INSTALL NEW PERIOD APPROPRIATE BATHROOM FIXTURES AND EQUIPMENT.
CONTRACTOR TO DOCUMENT AND RECEIVE APPROVAL FROM ARCHITECT AND OWNER
BEFORE REMOVAL AND INSTALLATION OF NEW FIXTURES AND EQUIPMENT. NEW FIXTURES ARE
TO BE PERIOD APPROPRIATE TO BE USED AS A EXHIBIT AND NOT TO BE FUNCTIONAL. SHALL
APPEAR FUNCTIONAL
INSTALL NEW PERIOD APPROPRIATE NON FUNCTIONING PLUMBING FIXTURES AND
ACCESSORIES WHERE INDICATED.
WOOD CASEWORK:
RESTORE ORIGINAL WOOD CASEWORK IN COTTAGE NO. #1. CLEAN AND RESTORE EXISTING
KITCHEN SINK. WHERE MATERIAL CAN NOT BE SALVAGE, CONTRACTOR SHALL DOCUMENT
EXISTING DIMENSION, STYLE AND PATTERNS BEFORE REMOVAL. INSTALL NEW CASEWORK TO
MATCH HISTORIC ELEMENTS. REPLACE EXISTING DOOR HARDWARE, CLEAN, CAULK, PRIME
AND PAINT WOOD TO MATCH EXISTING COLOR AND SHEEN.
WOOD FLOORING:
CAREFULLY REMOVE EXISTING DETERIORATED WOOD FLOORING TO IDENTIFY THE CONDITION OF THE
FLOOR JOIST FRAMING. REMOVE WOOD FLOORING AS NECESSARY TO EXPOSE THE EXTENT OF
DETERIORATION. SHORE IF NECESSARY. REMOVE DETERIORATED PORTIONS OF FLOOR FRAMING
MEMBERS THAT ARE NOT SALVAGEABLE AND SISTER BOTH SIDES PROPERLY WITH NEW PRESSURE TREATED MEMBER TO MATCH EXISTING DIMENSION. EXTEND SISTER 4’FEET BEYOND DETERIORATED
PORTION OF FRAMING AND FASTEN TO SOUND PORTIONS OF EXISTING MEMBER IN A STAGGARD
PATTERN EVERY 6” O.C. WITH 3” DECKING SCREWS. IF FRAMING MEMBER IS DETERIORATED OVER HALF ITS LENGTH, REMOVE ENTIRE MEMBER AND REPLACE WITH NEW PRESSURE TREATED MEMBER, TO MATCH EXISTING DIMENSION. TREAT ALL WALL CAVITIES, FRAMING, AND UNEXPOSED SURFACES WITH BORA-CARE PER MANUFACTURER’S RECOMMENDATIONS. REINSTALL ALL SALVAGEABLE WOOD FLOORING AND SUPPLEMENT WITH SALVAGED FLOORING AND NEW TO MATCH EXISTING. LIGHT SAND ENTIRE FLOOR AND SEAL WITH SATIN URETHANE FINISH. INSTALL NEW TRIM IN MATCHING PROFILES WHERE THE EXISTING TRIM IS MISSING OR DETERIORATED. SINK ALL NAIL HEADS. PREVIOUSLY PAINTED TRIM SHALL BE SANDED, CLEANED, PRIMED AND PAINTED, 2 COATS. COLOR TO BE CHOSEN BY OWNER AND ARCHITECT. THE CONTRACTOR SHALL INCLUDE A BASE BID OF 150 BDFT OF FLOOR
FRAMING REPAIR/SISTER/REPLACEMENT.
EXHIBIT PARTITION:
CONTRACTOR TO INSTALL NEW WOOD/PLEXIGLASS PARTITION IN EXHIBIT SPACE. PRECUT
P.T. WOOD MULLION AND P.T. WOOD RAILS TO SIZE. ADHERE PREMIUM SILICONE
SEALANT AROUND PERIMETER OF ½” PLEXIGLASS AND ADHERE PLEXIGLASS TO RAILS.
ATTACH STAINLESS STEEL HINGE AND LATCH SYSTEM WHERE INDICATED ON PLANS.
FIELD VERIFY ALL DIMENSIONS.
ELECTRICAL:
INSTALL NEW ELECTRICAL PANEL SYSTEM ON EXTERIOR OF BUILDING WHERE INDICATED.
ELECTICAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS. CONTRACTOR SHALL
COORDINATE WITH CITY UTILITIES FOR POLE FEEDER LINE INSTALLATION. INSTALL NEW
LIGHTING CIRCUITS FOR CEILING FIXTURS, AND SITE LIGHTING. SALVAGE/REPLACE, AS NEEDED
TO MATCH EXISTING FIXTURES. EXISTING POWER CONDUITS SHALL SUBMIT SHOP DRAWINGS
OF PROPOSED LIGHTING FIXTURES FOR OWNER AND ARCHITECTS APPROVAL.
CISTERN REPAIR:
REFURBISH EXISTING CONCRETE CISTERN. REMOVE EXISTING VEGETATION FROM TOP AND
SIDES OF CISTERN. INSTALL NEW PIPPING AND ELECTRICAL REQUIREMENTS FOR CISTERN
PUMP. PLUMBING CONTRACTOR SHALL PROVIDE ADEQUATE SIZING FOR SUMP PUMP.
ELECTRICAL CONTRACTOR SHALL PROVIDE POWER IRRIGATION CONTROLLER AND
DISCONNECT TOGGLE SWITCH FOR CISTERN PUMP. LOCATE SWITCH AND GFCI RECEPTACLE IN
NON-PLASTIC WEATHERPROOF COVER. INSTALL EXTERNAL LEAF DEBRIS BASKET FROM
INFLOW DOWNSPOUTS, AS DETAILED.
REPAIR SPALLED/CRACKED CONCRETE CISTERN WALLS. CONTRACTOR SHALL SUBMIT ALL
REPAIR PRODUCT DATA FOR REVIEW AND APPROVAL PRIOR TO BEING PERFORMED. SAW
CUT RECTANGULAR CUTOUT AT THE PERIMETER OF CONCRETE REPAIR AREA. LOCATE SAW
CUT A MINIMUM OF 1/2" BEYOND SPALL EDGE OR CRACK LINE. EXTEND THE DISTANCE O
SAW CUT LOCATION AS REQUIRED TO EXPOSED UNDAMAGED CONCRETE. CHIP AND
REMOVE ALL UNSOUND CONCRETE. ALSO REMOVE CONCRETE TO A MINIMUM OF 3/4"
CLEAR ABOVE OR BEYOND THE REINFORCING BARS. CLEAN EXPOSED STEEL AND REMOVE
LOOSE RUST AND CORROSION BY MECHANICALLY WIRE BRUSH, HAND TOOL CLEAN AND
SOLVENT CLEAN. WORKMEN MUST BE CAREFUL NOT TO DAMAGE OR WEAKEN STRUCTURAL
SUPPORT IN THE PROCESS OF CHIPPING AND ABRADING. CONTRACTOR SHALL NOTIFY
ARCHITECT TO ALLOW AN OPPORTUNITY TO REVIE CONDITIONS OF THE CONCRETE AND
REINFORCING BEFORE CONTINUING WITH REPAIR. PREPARE THE REINFORCING STEEL AND
EXISTING CONCRETE SUBSTRATE IN ACCORDANCE WITH THE REPAIR PRODUCT
MANUFACTURERS’ RECOMMENDATIONS. COAT STEEL WITH AN ANTI-CORROSION EPOXY
RESIN AND MORTAR BONDING AGENT. REPLACE REMOVED CONCRETE USING NON-SAG
POLYMER MODIFIED CEMENTITIOUS MORTAR SUITABLE FOR VERTICAL OR OVERHEAD
APPLICATIONS. CURE PER MANUFACTURERS RECOMMENDATIONS. MATCH TEXTURE OF
SURROUNDING CONCRETE. ARCHITECTS AND OWNER TO INSPECT MOCKUP SAMPLE FOR
APPROVAL PRIOR TO WORK. BASE BID TO INCLUDE 12 CUBIT FEET OF CONCRETE REPAIR.
CONTRACTOR TO PROVIDE ADDITIVE/DEDUCTIVE UNIT COST FOR CONSTRUCTION REPAIR
($____/CU. FT.)
HAZARDOUS MATERIAL ABATEMENT:
CONTRACTOR SHALL IDENTIFY ANY HAZARDOUS MATERIALS WITHIN THE SCOPE OF WORK.
CONTRACTOR TO COMPLY WITH ABATEMENT/ REMEDIATION PROCEDURES TO PERFORM
LIMITED ABATEMENT ON LEAD CONTAINING PAINT. ABATEMENT/REMEDIATION INCLUDES
REMOVAL OF ALL LOOSE LEAD PAINT FROM ALL SURFACES. CONTRACTOR TO SPOT PRIME
ALL RAW WOOD, AND SCRAPED PAINT AND EDGES. SALVAGE EXISTING WOOD TRIM AND
MOLDING TO BE SCRAPED, SANDED AND CLEANED BY ABATEMENT CONTRACTOR IF TO BE
REUSED. CONTRACTOR SHALL PROPERLY COLLECT AND DISPOSE OF ALL HAZARDOUS
MATERIALS IN A CERTIFIED FACILITY. ALL ABATEMENT/ REMEDIATION PROCEDURES MUST BE
COMPLIANT WITH O.S.H.A. AND E.P.A. REGULATIONS. CONTRACTOR RESPONSIBLE FOR
PROVIDING AIR MONITORING AS NECESSARY AND FINAL CLEARANCES PERFORMED BY AN
ENVIRONMENTAL CONSULTANT. ENVIRONMENTAL CONSULTANT SHALL BE APPROVED BY
ARCHITECT AND OWNER.
WALL TYPES
WORK NOTES CONTINUED
CONTRACTOR SHALL IDENTIFY ANY HAZARDOUS MATERIALS WITHIN THE SCOPE OF WORK.
CONTRACTOR SHALL COMPLY WITH ABATEMENT PROCEDURES FOR ASBESTOS CONTAINING
MATERIALS, SPECIFICALLY GLAZING COMPOUND ON HISTORIC WOOD WINDOWS AND ANY
MISC. INSULATION OR MASTICS. CONTRACTOR SHALL PROPERLY COLLECT AND DISPOSE OF
ALL HAZARDOUS MATERIALS IN A CERTIFIED FACILITY. ALL ABATEMENT PROCEDURES MUST BE
COMPLIANT WITH O.S.H.A. AND E.P.A. REGULATIONS. CONTRACTOR RESPONSIBLE FOR
PROVIDING AIR MONITORING AS NECESSARY AND FINAL CLEARANCES PERFORMED BY AN
ENVIRONMENTAL CONSULTANT. ENVIRONMENTAL CONSULTANT SHALL BE APPROVED BY
ARCHITECT AND OWNER.
SITE WORK:
CONTRACTOR TO INSTALL NEW 4” 3,000 PSI CONCRETE SIDEWALK W/ FIBER MESH
REINFORCED AND A 0.02% SLOPE. SAW CUT CONTROL JOINTS @ 5’ O.C.
CONTRACTOR SHALL INSTALL MUSEUM SIGNAGE PER OWNERS SPECIFICATIONS WHERE
INDICATED ON PLANS.
INSTALL NEW PREASSURED TREATED WOOD RAMP AS DETAILED AND INDICATED IN THE
DRAWINGS. PROVIDE HANDRAILS WITH CURB RAIL AROUND LANDING, AT RAMP AS DETAILED
AND INDICATED IN THE DRAWINGS. PROVIDE 5'X5' LEVEL CONCRETE LANDING AT THE BOTTOM
OF RAMP AS DETAILED AND INSTALL NEW ADA PARKING SPOT.
OUTDOOR CLASSROOM:
CONTRACTOR TO INSTALL PRE-ENGINEERED FREE-STANDING OPEN-AIR PAVILION.
STRUCTURE SHALL BE A GLUE LAMINATED PAVILION OVER A 4” 3,000 PSI CONCRETE DECK/
PAD W/ FIBER MESH REINFORCED AND A 0.02% SLOPE. SAW CUT CONTROL JOINTS @ 5’
O.C. CONTRACTOR SHALL FURNISH TAPERED GLUED LAMINATED SOUTHERN PINE BEAMS.
ROOF DECKING SHALL BE TONGUE AND GROOVE 2X8 KILN DRIED AND FURNISHED IN
SPECIFIED LENGTHS SUCH THAT ALL JOINTS OCCUR OVER THE BEAMS. INSTALL SYNTHETIC
WATERPROOFING UNDERLAYMENT OVER ROOF DECKING AND SELF ADHERED RUBBERIZED
ASPHALT UNDERLAYMENT ALONG THE RIDGE AND PERIMETER OF ROOF EDGE. INSTALL 2" HIGH
STANDING SEAM PREFINISHED ALUMINIZED STEEL METAL ROOF PANEL SYSTEM WITH
CONCEALED ANCHOR CLIPS OVER INSULATION. PANELS SHALL BE ROLLFORMED IN
CONTINUOUS PANEL LENGTH WITH NO LAP JOINT FROM EAVE TO PEAK. ROOF PANELS TO
HAVE BREAD PANNED ENDS WITH "Z" CLOSURES, AND EAVE EDGE TO BE HEMMED AND
CLEATED. ALL MECHANICAL FASTENERS (MIN. 2 FASTENERS PER EACH CLIP) SHALL ANCHOR
INTO P.T. WOOD BATTENS. INSTALL TO MEET FBC WIND UPLIFT OF REQUIREMENTS. INSTALL
PREFINISHED METAL RIDGE CAP, RAKE FLASHING, AND EDGE METAL TRIM, AS DETAILED.
INSTALL 6" PREFINISHED ALUMINUM GUTTER AND DOWNSPOUT SYSTEM. ROUTE GUTTER
OUTFALL BEHIND NEW PARTITION WALL, STRAP EVERY 24" O.C. ONTO EXISTING CISTERN FOR
REUSE.
CONTRACTOR SHALL VERIFY FOUNDATION DESIGN WITH CANOPY MANUFACTURER. PROVIDE
SIGN & SEAL SHOP DRAWINGS FROM A FLORIDA LICENSED ENGINEER FOR APPROVAL.
WIND SPEED: 170 MPH
RISK CATEGORY: II
EXPOSURE CLASSIFICATION: C
CONTRACTOR SHALL INSTALL P.T. WOOD 6X6 COLUMNS MEMBER SIZED TO MEET WIND
UPLIFT REQUIREMENTS. COLUMNS SHALL BE EMBEDDED TO A MINIMUM OF 3' BELOW
FINISHED GRADE.
INSTALL NEW PARTITION WALL WITH P.T. 4X4 WOOD POST TO EXTEND BELOW PAVILION
DECK. CONTRACTOR SHALL INSTALL 2X6 P.T. WOOD OVER COLUMNS, AS DETAILED.
ADDITIVE ALTERNATE ONE:
ALL WORK NOTED TO BE COMPLETED IN COTTAGE #1 SHALL BE COMPLETED IN COTT. #2.
ADDITIVE ALTERNATE TWO:
ALL WORK NOTED TO BE COMPLETED IN COTTAGE #1 SHALL BE COMPLETED IN COTT. #3.
ALT#1
ALT#2
WORK NOTES
DEMOLITION:
DEMOLISH EXISTING COTTAGE NUMBER #4, SALVAGE EXISTING ADJACENT CONCRETE
CISTERN.
REMOVE ALL NON-HISTORIC ADDITIONS (SHOWER) IN COTTAGES NUMBER #1, #2 AND #3.
TEMPORARILY DRY-IN AND PREPARE FOR WALL REBUILD.
CONTRACTOR SHALL REMOVE LOOSE/DAMAGED INTERIOR DEBRIS FROM ALL COTTAGES NO.
#2 AND #3. THE CONTRACTOR SHALL GIVE THE OWNER THE OPTION TO SALVAGE AS MUCH
MATERIAL AS POSSIBLE TO BE USED IN A FUTURE RESTORATION PHASE. ALL OWNER CHOSEN
SALVAGEABLE ITEMS SHOULD BE REMOVED, CLEANED, STACKED, PALLETIZED, AND
TRANSPORTED TO AN OFF-SITE STORAGE AREA. CONTRACTOR TO NOTIFY ARCHITECT AND
OWNER BEFORE REMOVAL OF ANY INTERIOR ARCHITECTURAL HISTORICAL ELEMENTS, AND TO
NOTIFY ARCHITECT AND OWNER IMMEDIATELY OF ANY CONCERNS DURING DEBRIS REMOVAL
OR IF ANY CONCEALED CONDITIONS ARE DISCOVERED.
FOUNDATION:
ON COTTAGES NUMBER #1, #2 AND #3 CONTRACTOR SHALL INSTALL MODULAR BUILDING
ANCHORAGE, INCLUDING WOOD ATTACHMENT RATED FOR 3,000 LBS.
ROOF:
CAREFULLY REMOVE EXISTING ROOFING SYSTEM DOWN TO THE EXISTING ROOF DECK ON ALL
COTTAGES. BASE BID TO INCLUDE 20 LF OF ROOF BEAM REPLACEMENT. CONTRACTOR TO
PROVIDE ADDITIVE/DEDUCTIVE LINEAR FEET UNIT COST ($__/ BF) FOR ADDITIONAL ROOF
BEAM REPLACEMENT. INSTALL 5/8" P.T. PLYWOOD PANEL OVER EXISTING WOOD ROOF
BEAMS, INSTALL SYNTHETIC WATERPROOFING UNDERLAYMENT OVER ROOF DECKING AND
SELF ADHERED RUBBERIZED ASPHALT UNDERLAYMENT. INSTALL 24” WIDE 5V CRIMP METAL
ROOF PANELS WITH GROMMET/SELF SEALING SCREW FASTENERS PER MANUFACTURER'S
FASTENING RECOMMENDATIONS TO MEET FBC WIND UPLIFT REQUIREMENTS INTO ROOF
DECKING. INSTALL PREFINISHED METAL RIDGE CAP, RAKE FLASHING, AND EDGE METAL TRIM, AS DETAILED.
EX
EX A
A500
EXISTING WALL
NEW WALL. SEE WALL TYPES
ELEVATION/SECTION NUMBER
SHEET NUMBER
WORK LEGEND NOTE
PHOTO MARKER
PHOTO # / SHEET #
AWNING ABOVE
METAL ROOF PANELS
NOT IN CONTRACT
HEART PINE WOOD FLOOR
CONCRETE LANDING
N.I.C.
A.F.F.
B.F.F.
TYP.
MIR.
EXISTING DOOR TO
REMAIN
EXISTING WINDOW TO
REMAIN
ROOM NAME
NOT IN CONTRACT
ABOVE FINISH FLOOR
BELOW FINISH FLOOR
TYPICAL
MIRROR
ROOF SLOPE
ROOF RIDGE
ELEVATION MARKER
1/A100
RIDGE
N.I.C.
ROOM
CONSULTANTS
A001
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
EXISTING SITE PLAN
O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
LEGEND
8/19/2024
A100
A101
A102
N
SCALE: 1/8" = 1'-0"
1 EXISTING SITTE PLAN
A001 0 4' 8' 16'
COTTAGE #1
COTTAGE #2
COTTAGE #3
COTTAGE #4
EXISTING
CISTERN
A500
EXISTING WALL
NEW WALL. SEE WALL TYPES
ELEVATION/SECTION NUMBER
SHEET NUMBER
WORK LEGEND NOTE
PHOTO MARKER
PHOTO # / SHEET #
AWNING ABOVE
METAL ROOF PANELS
NOT IN CONTRACT
HEART PINE WOOD FLOOR
CONCRETE LANDING
N.I.C.
A.F.F.
B.F.F.
EXISTING WINDOW TO
REMAIN
ROOM NAME
NOT IN CONTRACT
ABOVE FINISH FLOOR
BELOW FINISH FLOOR
TYPICAL
MIRROR
ROOF SLOPE
ROOF RIDGE
ELEVATION MARKER
1/A100
RIDGE
N.I.C.
ROOM
CONSULTANTS
A002
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
PROPOSED SITE PLAN
O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
LEGEND
8/19/2024
A100
A102
2A101
N
SCALE: 1/8" = 1'-0"
1 PROPOSED SITE PLAN
A002 0 4' 8' 16'
NEW 6'-0" WROUT IRON FENCING
COTTAGE #1
COTTAGE #2
COTTAGE #3
OUTDOOR
CLASSROOM
EXISTING
CISTERN
SITE WORK:
CONTRACTOR TO INSTALL NEW 4” 3,000 PSI CONCRETE SIDEWALK W/ FIBER MESH
REINFORCED AND A 0.02% SLOPE. SAW CUT CONTROL JOINTS @ 5’ O.C.
CONTRACTOR SHALL INSTALL MUSEUM SIGNAGE PER OWNERS SPECIFICATIONS WHERE
INDICATED ON PLANS.
INSTALL NEW PREASSURED TREATED WOOD RAMP AS DETAILED AND INDICATED IN THE
DRAWINGS. PROVIDE HANDRAILS WITH CURB RAIL AROUND LANDING, AT RAMP AS
DETAILED AND INDICATED IN THE DRAWINGS. PROVIDE 5'X5' LEVEL CONCRETE LANDING
AT THE BOTTOM OF RAMP AS DETAILED AND INSTALL NEW ADA PARKING SPOT.
WORK NOTES
A500
EXISTING WALL
NEW WALL. SEE WALL TYPES
ELEVATION/SECTION NUMBER
SHEET NUMBER
WORK LEGEND NOTE
PHOTO MARKER
PHOTO # / SHEET #
AWNING ABOVE
METAL ROOF PANELS
NOT IN CONTRACT
HEART PINE WOOD FLOOR
CONCRETE LANDING
N.I.C.
A.F.F.
B.F.F.
EXISTING WINDOW TO
REMAIN
ROOM NAME
NOT IN CONTRACT
ABOVE FINISH FLOOR
BELOW FINISH FLOOR
TYPICAL
MIRROR
ROOF SLOPE
ROOF RIDGE
ELEVATION MARKER
1/A100
RIDGE
N.I.C.
ROOM
CONSULTANTS
A003
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
RESTROOM LOCATION
PLAN
G O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
LEGEND
8/19/2024
TRAVEL DISTANCE TO
NEAREST RESTROOM
407'-6"
MARGOOD
HARBOR PARK
MARGOOD
INTERPRETIVE
CENTER
PETTIT D
RIVE
N
SCALE: 1/16" = 1'-0"
1 RESTROOM LOCATION PLAN
A003 0 8' 16' 32'
2023 FLORIDA BUILDING CODE - BUILDING, EIGHTH EDITION, CHAPTER 29 PLUMBING SYSTEMS, SECTION
[P]2902.3.3 LOCATION OF TOILET FACILITIES IN OCCUPANCIES OTHER THAN MALLS.
IN OCCUPANCIES OTHER THAN COVERED AND OPEN MALL BUILDINGS, THE REQUIRED PUBLIC
AND EMPLOYEE TOILET FACILITIES SHALL BE LOCATED NOT MORE THAN ONE STORY ABOVE OR
BELOW THE SPACE REQUIRED TO BE PROVIDED WITH TOILET FACILITIES, AND THE PATH OF
TRAVEL TO SUCH FACILITIES SHALL NOT EXCEED A DISTANCE OF 500 FEET (152 M).
2023 FBC BUILDING CODE - NOTE
A500
EXISTING WALL
NEW WALL. SEE WALL TYPES
ELEVATION/SECTION NUMBER
SHEET NUMBER
WORK LEGEND NOTE
PHOTO MARKER
PHOTO # / SHEET #
AWNING ABOVE
METAL ROOF PANELS
NOT IN CONTRACT
HEART PINE WOOD FLOOR
CONCRETE LANDING
N.I.C.
A.F.F.
B.F.F.
EXISTING WINDOW TO
REMAIN
ROOM NAME
NOT IN CONTRACT
ABOVE FINISH FLOOR
BELOW FINISH FLOOR
TYPICAL
MIRROR
ROOF SLOPE
ROOF RIDGE
ELEVATION MARKER
1/A100
RIDGE
N.I.C.
ROOM
CONSULTANTS
A100
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
COTTAGE #1 FLOOR
PLANS
G O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
LEGEND
8/19/2024
COTTAGE
NO. 1
B
A
A
A
A
A200
A200
A200
±3'-9"±17'-7"11'-9"
4'-4"5'12'
'-6
'-9
5'
'-7
A200
UP
A301
A302
A300
A502
5'
A301
COTTAGE
NO. 1
EXISTING FLOOR GIRDER LOCATION.
2x8 P.T. JOIST @16" O.C. TYP.
6x6 P.T. COLUMN WITH 1'-6"
EMBEDMENT MIN. (TYP.)
NEW CAST IN PLACE CONCRETE
STAIR FOUNDATION
EXISTING CMU COLUMN WITH SOOTH
PLASTER FINISH TO REMAIN (TYP.)
(2) 2x8 BEAM
MODULAR BUILDING ANCHORAGE
INCLUDING WOOD ATTACHMENT
RATED FOR 3,000 LBS. EACH (TYP.)
NN
N
SCALE: 1/4" = 1'-0"
1 COTTAGE NO. 1 DEMOLITION PLAN
A100 0 2' 4' 8' SCALE: 1/4" = 1'-0"
2 COTTAGE NO. 1 RENOVATION PLAN
A100 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
3 COTTAGE NO. 1 FRAMING PLAN
A100 0 2' 4' 8'
2626 2424
A500
EXISTING WALL
NEW WALL. SEE WALL TYPES
ELEVATION/SECTION NUMBER
SHEET NUMBER
WORK LEGEND NOTE
PHOTO MARKER
PHOTO # / SHEET #
AWNING ABOVE
METAL ROOF PANELS
NOT IN CONTRACT
HEART PINE WOOD FLOOR
CONCRETE LANDING
N.I.C.
A.F.F.
B.F.F.
EXISTING WINDOW TO
REMAIN
ROOM NAME
NOT IN CONTRACT
ABOVE FINISH FLOOR
BELOW FINISH FLOOR
TYPICAL
MIRROR
ROOF SLOPE
ROOF RIDGE
ELEVATION MARKER
1/A100
RIDGE
N.I.C.
ROOM
CONSULTANTS
A101
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
COTTAGE #2 FLOOR
PLANS
G O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
LEGEND
8/19/2024
BA
A
'-1
'-2
±3'-9"±17'-7"
2'-3"
5'
1'
3' -6
" M
IN
UP
A300
±21'-4"
1'-6"
4'2'-3"4'
COTTAGE
NO. 2
COTTAGE
NO. 2
EXISTING FLOOR GIRDER LOCATION.
NEW CAST IN PLACE CONCRETE
STAIR FOUNDATION
2x8 P.T. JOIST @16" O.C. TYP.
6x6 P.T. COLUMN WITH 1'-6"
EMBEDMENT MIN. (TYP.)
(2) 2x8 BEAM(2) 2x8 BEAM
EXISTING CMU COLUMN WITH SOOTH
PLASTER FINISH TO REMAIN (TYP.)
MODULAR BUILDING ANCHORAGE
INCLUDING WOOD ATTACHMENT
RATED FOR 3,000 LBS. EACH (TYP.)
NN
SCALE: 1/4" = 1'-0"
2 COTTAGE NO. 2 RENOVATION PLAN (ADD ALT. #1)
A101 0 2' 4' 8'SCALE: 1/4" = 1'-0"
1 COTTAGE NO. 2 DEMOLITION PLAN (ADD ALT. #1)
A101 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
3 COTTAGE NO. 2 FRAMING PLAN (ADD ALT. #1)
A101 0 2' 4' 8'
ALT #1
A500
EXISTING WALL
NEW WALL. SEE WALL TYPES
ELEVATION/SECTION NUMBER
SHEET NUMBER
WORK LEGEND NOTE
PHOTO MARKER
PHOTO # / SHEET #
AWNING ABOVE
METAL ROOF PANELS
NOT IN CONTRACT
HEART PINE WOOD FLOOR
CONCRETE LANDING
N.I.C.
A.F.F.
B.F.F.
EXISTING WINDOW TO
REMAIN
ROOM NAME
NOT IN CONTRACT
ABOVE FINISH FLOOR
BELOW FINISH FLOOR
TYPICAL
MIRROR
ROOF SLOPE
ROOF RIDGE
ELEVATION MARKER
1/A100
RIDGE
N.I.C.
ROOM
CONSULTANTS
A102
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
COTTAGE #3 AND
OUTDOOR
CLASSROOM PLANS
G O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
LEGEND
8/19/2024
EX
B
A
A
2'-3"15'-6"2'-3"
20'
1'5'
7'-6" 5' 7'-6"
36' 5'
±4"
±6'-6 1/2" ±5'-8 1/2"
5'
2' 5'-6" 5' 5'-6" 2'
'-7
'-9
5'
A303
A303
A103
A3033
A303
A303
A
CC
'-4
'-8
'-4
'-9
5'
6'-7"5'6'5'
COTTAGE
NO. 3
OUTDOOR CLASSROOM
OLD CISTERN
COTTAGE
NO. 3
OLD CISTERN
COTTAGE NO. 4
GARAGE / STORAGE
N
N
SCALE: 1/4" = 1'-0"
2 OUTDOOR CLASSROOM (BASE BID) AND COTTAGE NO. 3 (ADD ALT. #2) FLOOR PLAN
A102 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
1 COTTAGE NO. 4 (BASE BID) AND COTTAGE NO. 3 (ADD ALT. #2) DEMOLITION PLAN
A102 0 2' 4' 8'
3838 38
ALT #2
A500
EXISTING WALL
NEW WALL. SEE WALL TYPES
ELEVATION/SECTION NUMBER
SHEET NUMBER
WORK LEGEND NOTE
PHOTO MARKER
PHOTO # / SHEET #
AWNING ABOVE
METAL ROOF PANELS
NOT IN CONTRACT
HEART PINE WOOD FLOOR
CONCRETE LANDING
N.I.C.
A.F.F.
B.F.F.
EXISTING WINDOW TO
REMAIN
ROOM NAME
NOT IN CONTRACT
ABOVE FINISH FLOOR
BELOW FINISH FLOOR
TYPICAL
MIRROR
ROOF SLOPE
ROOF RIDGE
ELEVATION MARKER
1/A100
RIDGE
N.I.C.
ROOM
CONSULTANTS
A103
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
COTTAGE #3 FRAMING
AND OUTDOOR CLASS.
FOUNDATION PLANS
G O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
LEGEND
8/19/2024
15'-6"
EXISTING FLOOR GIRDER
LOCATION
NEW CAST IN PLACE CONCRETE
STAIR FOUNDATION
2x8 P.T. JOIST @16" O.C. TYP.
CMU COLUMN WITH SOOTH
PLASTER FINISH TO REMAIN (TYP.)
2x8 P.T. JOIST @16" O.C. TYP.2x8 P.T. JOIST @16" O.C. TYP.
2x8 P.T. JOIST @16" O.C. TYP.2x8 P.T. JOIST @16" O.C. TYP.
6x6 P.T. COLUMN WITH 1'-6"
EMBEDMENT MIN. (TYP.)
(2) 2x8 BEAM(2) 2x8 BEAM
MODULAR BUILDING ANCHORAGE
INCLUDING WOOD ATTACHMENT
RATED FOR 3,000 LBS. EACH (TYP.)
6x6 P.T. COLUMN WITH 1'-6"
EMBEDMENT MIN. (TYP.)
EXISTING CMU COLUMN WITH SOOTH
PLASTER FINISH TO REMAIN (TYP.)
6x6 P.T. COLUMN WITH 3'-0"
EMBEDMENT MIN. (TYP.)
EXISTING CISTERN TO REMAIN
CONTRACTOR SHALL VERIFY
FOUNDATION DESIGN WITH
CANOPY MANUFACTURER.
PROVIDE SIGN & SEAL SHOP
DRAWINGS FROM A FLORIDA
LICENSED ENGINEER FOR
APPROVAL.
CONTRACTOR SHALL VERIFY
FOUNDATION DESIGN WITH
CANOPY MANUFACTURER.
PROVIDE SIGN & SEAL SHOP
DRAWINGS FROM A FLORIDA
LICENSED ENGINEER FOR
APPROVAL.
PREFINISHED 6" Ø
DOWNSPOUT
INFLOW
PREFINISHED 4" Ø
DOWNLEADER
INFLOW (1/4" PER
FOOT SLOPE MIN.)
±0'-0"
SLAB
±10'-9"
RIDGE
±8'-0"
CLEARANCE
20'
A103
A3033
A303
A303
R
ID
G
E DS
DS
N
N
SCALE: 1/4" = 1'-0"
3 OUTDOOR CLASSROOM FOUNDATION PLAN AND COTTAGE NO. 3 FRAMING PLAN (ADD ALT. #2)
A103 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
2 SOUTH ELEVATION
A103 0 2' 4' 8'SCALE: 1/4" = 1'-0"
1 OUTDOOR CLASSROOM ROOF PLAN
A103 0 2' 4' 8'
A500
EXISTING WALL
NEW WALL. SEE WALL TYPES
ELEVATION/SECTION NUMBER
SHEET NUMBER
WORK LEGEND NOTE
PHOTO MARKER
PHOTO # / SHEET #
AWNING ABOVE
METAL ROOF PANELS
NOT IN CONTRACT
HEART PINE WOOD FLOOR
CONCRETE LANDING
N.I.C.
A.F.F.
B.F.F.
EXISTING WINDOW TO
REMAIN
ROOM NAME
NOT IN CONTRACT
ABOVE FINISH FLOOR
BELOW FINISH FLOOR
TYPICAL
MIRROR
ROOF SLOPE
ROOF RIDGE
ELEVATION MARKER
1/A100
RIDGE
N.I.C.
ROOM
CONSULTANTS
A200
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
EXTERIOR ELEVATIONS
O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
LEGEND
8/19/2024
±13'-9"
ROOF RIDGE
±1'-2"
COTTAGE FLOOR
±12'-0"
RIDGE
0'-0"
SITE
±13'-9"
ROOF RIDGE
±1'-2"
COTTAGE FLOOR
0'-0"
SITE
±13'-9"
ROOF RIDGE
±1'-2"
COTTAGE FLOOR
±12'-0"
RIDGE
0'-0"
SITE
±13'-9"
ROOF RIDGE
±1'-2"
COTTAGE FLOOR
0'-0"
SITE
±12'-0"
RIDGE
SCALE: 1/4" = 1'-0"
4 SOUTH ELEVATION - COTTAGE NO.1 (TYP. FOR COTTAGES #2 & #3)
A200 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
2 WEST ELEVATION - COTTAGE NO.1 (TYP. FOR COTTAGES #2 & #3)
A200 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
1 NORTH ELEVATION -COTTAGE NO.1 (TYP. FOR COTTAGES #2 & #3)
A200 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
3 EAST ELEVATION - COTTAGE NO.1 (TYP. FOR COTTAGES #2 & #3)
A200 0 2' 4' 8'
10 17
9 9
10 12
10 12
10 12
5 5
6 7
6 7
9 9
A300
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
SECTIONS
O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
8/19/2024
EXISTING NOVELTY COVE SIDING. REPLACE ANY DAMAGED
OR DETERIORATED SIDING WITH NEW MATERIAL AS
REQUIRED. REMOVE LOOSE CRACKED PAINT, CLEAN, PRIME
AND PAINT
NEW STAINLESS STEEL HANDRAILS
CONTRACTOR TO INSTALL NEW 4”
3,000 PSI CONCRETE SIDEWALK
W/ FIBER MESH REINFORCED AND
A 0.02% SLOPE. SAW CUT
CONTROL JOINTS @ 5’ O.C.
INSTALL 5/8" P.T. PLYWOOD PANEL OVER EXISTING WOOD
ROOF BEAMS, INSTALL SYNTHETIC WATERPROOFING
UNDERLAYMENT OVER ROOF DECKING AND SELF ADHERED
RUBBERIZED ASPHALT UNDERLAYMENT ALONG THE RIDGE
AND PERIMETER OF ROOF EDGE. INSTALL 24” WIDE 5V
CRIMP METAL ROOF PANELS WITH GROMMET/SELF SEALING
SCREW FASTENERS
EXISTING NOVELTY COVE
SIDING. REPLACE ANY
DAMAGED OR
DETERIORATED SIDING
WITH NEW MATERIAL AS
REQUIRED. REMOVE
LOOSE CRACKED PAINT,
CLEAN, PRIME AND PAINT
A500
A500
A500
1' 1' 1'
FI
EL
D V
ER
IF
Y
' C
EI
LI
N G
H
EI
G H T
' C
EI
LI
N G
H
EI
G H T
'-4
±8'-3"
AWNING EAVE EDGE
±13'-4"
RIDGE
0'-0"
SITE
±1-2"
TOP OF RAMP LANDING
A502
A502
5'-1" 10"
1'-8"
NEW MONOLITIC CONCRETE SLAB. MIN. 3000
PSI W/ #4 REBAR @ 24" O.C. EACH WAY
INSTALL MODULAR BUILDING
ANCHORAGE, INCLUDING WOOD
ATTACHMENT RATED FOR 3,000
LBS.
INSTALL NEW WOOD/PLEXIGLASS PARTITION IN EXHIBIT SPACE. PRECUT P.T. WOOD
MULLION AND P.T. WOOD RAILS TO SIZE. ADHERE PREMIUM SILICONE SEALANT AROUND
PERIMETER OF ½” PLEXIGLASS AND ADHERE PLEXIGLASS TO RAILS. ATTACH STAINLESS
STEEL HINGE AND LATCH SYSTEM WHERE INDICATED ON PLANS. FIELD VERIFY ALL
DIMENSIONS.
INSTALL MODULAR BUILDING
ANCHORAGE, INCLUDING WOOD
ATTACHMENT RATED FOR 3,000
LBS.
INSTALL NEW PERIOD
APPROPRIATE NON
FUNCTIONING PLUMBING
FIXTURES AND
ACCESSORIES WHERE
INDICATED.
INSTALL NEW PERIOD
APPROPRIATE NON
FUNCTIONING PLUMBING
FIXTURES AND
ACCESSORIES WHERE
INDICATED.
REMOVE EXISTING WOOD PANELING ON WALL, CEILINGS, INSTALL NEW BEADBOARD
WALLS, CEILINGS, AND VARIOUS. WHERE FACE NAILING IS NECESSARY, SINK NAILHEADS
BELOW SURFACE OF WOOD. INSTALL NEW TRIM IN MATCHING PROFILES WHERE EXISTING
TRIM IS MISSING/DAMAGED. CLEAN, CAULK, PRIME AND PAINT WOOD CEILINGS, WALLS,
TRIM, FRAMES, MOLDINGS, ETC. COLOR TO MATCH EXISTING COLOR AND SHEEN.
SCALE: 3/4" = 1'-0"
1 COTTAGE NO.1 LONGITUDINAL SECTION
A300 0 1' 2' 3'
A301
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
8/19/2024
EXISTING NOVELTY COVE SIDING. REPLACE ANY DAMAGED OR
DETERIORATED SIDING WITH NEW MATERIAL AS REQUIRED.
REMOVE LOOSE CRACKED PAINT, CLEAN, PRIME AND PAINT
NEW MONOLITIC CONCRETE SLAB. MIN. 3000 PSI W/ #4
REBAR @ 24" O.C. EACH WAY
NEW PRIFINISHED ALUMINUM FLASHING
5V CRIMP ROOF
SCRAPE LOOSE PAINT OFF FROM AWNING, SOFFIT AND
SUPPORTING ELEMENTS. SAND, PRIME AND PAINT 2 COATS
5V CRIMP ROOF
NEW MONOLITIC CONCRETE SLAB. MIN. 3000 PSI W/ #4
REBAR @ 24" O.C. EACH WAY
INSTALL 5/8" P.T. PLYWOOD PANEL OVER EXISTING WOOD
ROOF BEAMS, INSTALL SYNTHETIC WATERPROOFING
UNDERLAYMENT OVER ROOF DECKING AND SELF ADHERED
RUBBERIZED ASPHALT UNDERLAYMENT ALONG THE RIDGE
AND PERIMETER OF ROOF EDGE. INSTALL 24” WIDE 5V
CRIMP METAL ROOF PANELS WITH GROMMET/SELF SEALING
SCREW FASTENERS
EXISTING NOVELTY COVE SIDING. REPLACE ANY DAMAGED OR
DETERIORATED SIDING WITH NEW MATERIAL AS REQUIRED. REMOVE
LOOSE CRACKED PAINT, CLEAN, PRIME AND PAINT
RESTORE WINDOWS PER WORK NOTES
±13'-9"
ROOF RIDGE
±1'-2"
COTTAGE FLOOR
0'-0"
SITE
±8'-3"
AWNING EAVE EDGE
NEW ADA ACCESSIBLE STAINLESS STEEL 2" ALUMINUM PIPE
HANDRAIL
A500
A500
A502
A502 4
'-1 /2
'-6
'-6
NEW MONOLITIC CONCRETE
SLAB. MIN. 3000 PSI W/ #4
REBAR @ 24" O.C. EACH WAY
2X6 P.T. WOOD PLANKS OVER 2X8
P.T. JOIST @ 16" O.C.
2'-1" 3'-1" 3'-1" 3'-1" 1'-10 1/2" 2'-6" 1'-9"
17'-6"
0'-0"
SITE
±1-2"
TOP OF RAMP LANDING
NEW ADA ACCESSIBLE
STAINLESS STEEL 1 1/4"
ALUMINUM PIPE HANDRAIL
A502
A502
'-8
A502
SLOPE 1:12
SCALE: 3/4" = 1'-0"
1 RAMP LONGITUDINAL SECTION
A301 0 1' 2' 3'
SCALE: 3/4" = 1'-0"
2 COTTAGE NO.1 RAMP LONGITUDINAL SECTION
A301 0 1' 2' 3'
A302
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
8/19/2024
REPLACE EXISTING WOOD PANELING IN
WALL AND CEILING WITH NEW BEADBOARD
INTERIOR PANEL. PRIME AND PAINT 2
COATS
EXISTING NOVELTY COVE SIDING. REPLACE ANY DAMAGED
OR DETERIORATED SIDING WITH NEW MATERIAL AS
REQUIRED. REMOVE LOOSE CRACKED PAINT, CLEAN, PRIME
AND PAINT
NEW STAINLESS STEEL HANDRAILS
NEW MONOLITIC CONCRETE SLAB. MIN. 3000
PSI W/ #4 REBAR @ 24" O.C. EACH WAY
NEW STAINLESS STEEL HANDRAILS (BEYOND).
COORDINATE WITH PLAN
CONTRACTOR TO INSTALL NEW 4”
3,000 PSI CONCRETE SIDEWALK
W/ FIBER MESH REINFORCED AND
A 0.02% SLOPE. SAW CUT
CONTROL JOINTS @ 5’ O.C.
INSTALL 5/8" P.T. PLYWOOD PANEL OVER EXISTING WOOD
ROOF BEAMS, INSTALL SYNTHETIC WATERPROOFING
UNDERLAYMENT OVER ROOF DECKING AND SELF ADHERED
RUBBERIZED ASPHALT UNDERLAYMENT ALONG THE RIDGE
AND PERIMETER OF ROOF EDGE. INSTALL 24” WIDE 5V
CRIMP METAL ROOF PANELS WITH GROMMET/SELF SEALING
SCREW FASTENERS
A500
A500
A500
1'11"6"E.Q.E.Q.E.Q.
±8'-3"
AWNING EAVE EDGE
±13'-4"
RIDGE
0'-0"
SITE
±1-2"
TOP OF RAMP LANDING
RESTORE EXISTING HARD PINE FLOORING.
SUPPLEMENT DAMAGED FLOORING WITH
FLOORING FROM COTTAGE #2 AND #3, AS
NEEDED. REPLACE ANY DAMAGED TRIM, AS
NEEDED. PROFILE TO MATCH EXISTING.
LEVEL EXISTING DOOR THRESHOLD WITH
NEW CONCRETE LANDING
A502
A502
FI
EL
D V
ER
IF
Y
5'-1"10"4'-10"1'-8"
SCALE: 3/4" = 1'-0"
1 COTTAGE NO.1 STAIR SECTION
A302 0 1' 2' 3'
A303
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
8/19/2024
EXISTING CISTERN
NEW MONOLITIC CONCRETE SLAB. MIN. 3000
PSI W/ #4 REBAR @ 24" O.C. EACH WAY
PROPOSED 4"
CISTERN OVERFLOW
PREFINISHED 6"
GUTTER
GUTTER OUTFALL
±10'-9"
RIDGE
±8'-0"
CLEARANCE
±0'-0"
6X6 P.T. COLUM WITH
3' EMBEDMENT MIN.
COMPACT FILL (TYP.)
(5) #5 BARS THRU
POST @ 8" O.C.
CONTRACTOR SHALL VERIFY
FOUNDATION DESIGN WITH
CANOPY MANUFACTURER.
PROVIDE SIGN & SEAL SHOP
DRAWINGS FROM A FLORIDA
LICENSED ENGINEER FOR
APPROVAL.
CONTRACTOR SHALL VERIFY
FOUNDATION DESIGN WITH
CANOPY MANUFACTURER.
PROVIDE SIGN & SEAL SHOP
DRAWINGS FROM A FLORIDA
LICENSED ENGINEER FOR
APPROVAL.
TO IRRIGATION.
PLUMBING
DESIGN BY
IRRIGATION
CONTRACTOR
IRRIGATION PUMP
DESIGN BY SYSTEM
CONTRACTOR
FILTRATION
±0'-0"
SLAB
±10'-9"
RIDGE
±8'-0"
CLEARANCE
±0'-0"
SLAB
±10'-9"
RIDGE
±8'-0"
CLEARANCE
±0'-0"
SLAB
±10'-9"
RIDGE
±8'-0"
CLEARANCE
SCALE: 3/4" = 1'-0"
4 OUTDOOR CLASSROOM SECTION
A303 0 1' 2' 3'
SCALE: 1/4" = 1'-0"
2 EAST ELEVATION - OUTDOOR CLASSROOM
A303 0 2' 4' 8' SCALE: 1/4" = 1'-0"
3 WEST ELEVATION - OUTDOOR CLASSROOM
A303 0 2' 4' 8'SCALE: 1/4" = 1'-0"
1 NORTH ELEVATION - OUTDOOR CLASSROOM
A303 0 2' 4' 8'
A500
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
TYPICAL ROOF PLAN &
DETAILS
G O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
8/19/2024
POP RIVET AT 8" O.C.
RIDGE TRIM
OUTSIDE CLOSURE
5V CRIMP ROOF PANEL
EXISTING RAFTERS TO REMAIN
BUTYL TAPE SEALANT
HEAVY GUAGE 'Z' CLOSURE WITH PERFORATIONS
EXISTING PURLINS TO REMAIN
SELF ADHESIVE RUBBERIZED ASPHALT UNDERLAYMENT
NEW 5/8" P.T. PLYWOOD ROOF DECK
SYNTHETIC WATERPROOFING UNDERLAYMENT
EXISTING NOVELTY COVE SHIPLAP SIDING. REPLACE ANY DAMAGED
OR DETERIORATED SIDING WITH NEW MATERIAL AS REQUIRED.
REMOVE LOOSE CRACKED PAINT, CLEAN, PRIME AND PAINT
URETHANE SEALANT CONTINUOUS BEAD ALONG TOP OF CLOSURE
INSIDE CLOSURE
TRI-BEAD SEALANT
WOOD FASTENER WITH WASHER
5V CRIMP ROOF PANEL
SELF ADHESIVE RUBBERIZED ASPHALT UNDERLAYMENT
PANCAKE HEAD SELF-TAPPER FASTERNER AT 5'-0" O.C.
NEW PREFINISHED ALUMINUM EDGE
EXISTING RAFTERS TO REMAIN
NEW 5/8" P.T. PLYWOOD ROOF DECK
EXISTING PURLING TO REMAIN
SIMPSON STRONG TIE H2.5A AT EACH EXISTING RAFTER
SYNTHETIC WATERPROOFING UNDERLAYMENT
EXISTING NOVELTY COVE SHIPLAP SIDING. REPLACE ANY DAMAGED
OR DETERIORATED SIDING WITH NEW MATERIAL AS REQUIRED.
REMOVE LOOSE CRACKED PAINT, CLEAN, PRIME AND PAINT
PREFINISHED ALUMINUM RAKE TRIM
EXISTING WOOD FASCIA. REMOVE LOOSE CRACKED PAINT,
CLEAN, PRIME AND PAINT 2 COATS
5V CRIMP ROOF PANEL
SELF ADHESIVE RUBBERIZED ASPHALT UNDERLAYMENT
PANCAKE HEAD SELF-TAPPER FASTERNER AT 5'-0" O.C.
NEW 5/8" P.T. PLYWOOD ROOF DECK
EXISTING GABLE WALL RAFTER FRAMING BEYOND
EXISTING RAFTER TO REMAIN
EXISTING PURLINS TO REMAIN
SYNTHETIC WATERPROOFING UNDERLAYMENT
EXISTING NOVELTY COVE SHIPLAP SIDING. REPLACE ANY DAMAGED
OR DETERIORATED SIDING WITH NEW MATERIAL AS REQUIRED.
REMOVE LOOSE CRACKED PAINT, CLEAN, PRIME AND PAINT
5V CRIMP ROOF PANEL
EXISTING RAFTERS TO REMAIN
PANCAKE HEAD FASTERNER 8" O.C.
PREFINISHED ALUMINUM FLASHING
HIGH-TEMP BUTYL TAPE SEALANT
OUTSIDE CLOSURE
BUTYL TAPE SEALANT
EXISTING WOOD STUD FRAMING BEYOND
EXISTING WOOD PLANK ROOF DECKING. REPLACE ANY DAMAGED OR
DETERIORATED WOOD PLANK DECKING WITH NEW MATERIAL AS REQUIRED
SYNTHETIC WATERPROOFING UNDERLAYMENT
EXISTING WOOD FASCIA. REMOVE LOOSE CRACKED PAINT,
CLEAN, PRIME AND PAINT 2 COATS. REPLACE ANY DAMAGED OR
DETERIORATED WITH NEW MATERIAL AS REQUIRED
URETHANE SEALANT CONTINUOUS BEAD ALONG TOP OF CLOSURE
INSIDE CLOSURE
TRI-BEAD SEALANT
WOOD FASTENER WITH WASHER
5V CRIMP ROOF PANEL
SELF ADHESIVE RUBBERIZED ASPHALT UNDERLAYMENT
PANCAKE HEAD SELF-TAPPER FASTERNER AT 5'-0" O.C.
NEW PREFINISHED ALUMINUM EDGE
EXISTING RAFTERS, REMOVE LOOSE CRACKED PAINT, CLEAN,
PRIME AND PAINT 2 COATS.
EXISTING WOOD PLANK ROOF DECKING. REPLACE ANY DAMAGED
OR DETERIORATED WOOD PLANK DECKING WITH NEW MATERIAL AS
REQUIRED
SYNTHETIC WATERPROOFING UNDERLAYMENT
EXISTING NOVELTY COVE SHIPLAP SIDING.
REPLACE ANY DAMAGED OR DETERIORATED
SIDING WITH NEW MATERIAL AS REQUIRED.
REMOVE LOOSE CRACKED PAINT, CLEAN,
PRIME AND PAINT
5V CRIMP ROOF PANEL
PANCAKE HEAD FASTERNER 8" O.C.
PREFINISHED ALUMINUM RAKE WALL FLASHING
HIGH-TEMP BUTYL TAPE SEALANT
EXISTING WOOD STUD FRAMING BEYOND
NEW 5/8" P.T. PLYWOOD ROOF DECK
SYNTHETIC WATERPROOFING UNDERLAYMENT
EX
EX A
A500
EXISTING WALL
NEW WALL. SEE WALL TYPES
ELEVATION/SECTION NUMBER
SHEET NUMBER
WORK LEGEND NOTE
PHOTO MARKER
PHOTO # / SHEET #
AWNING ABOVE
WIDE 5V CRIMP METAL ROOF PANELS
NOT IN CONTRACT
HEART PINE WOOD FLOOR
CONCRETE LANDING
N.I.C.
A.F.F.
B.F.F.
EXISTING WINDOW TO
REMAIN
ROOM NAME
NOT IN CONTRACT
ABOVE FINISH FLOOR
BELOW FINISH FLOOR
TYPICAL
MIRROR
ROOF SLOPE
ROOF RIDGE
ELEVATION MARKER
1/A100
RIDGE
N.I.C.
ROOM
±19'-7" ±3'-9"
'-3
A500
A500
A500
A500
A500
A500
A500
A500
5 12
LOW LOW
RIDGE
RIDGE
RIDGE
SCALE: 3" = 1'-0"
2 RIDGE DETAIL
A500 0 3'' 6'' 9''
SCALE: 3" = 1'-0"
3 EAVE EDGE DETAIL
A500 0 3'' 6'' 9'' SCALE: 3" = 1'-0"
4 RAKE DETAIL
A500 0 3'' 6'' 9''
SCALE: 3" = 1'-0"
5 AWNING WALL BASE DETAIL
A500 0 3'' 6'' 9'' SCALE: 3" = 1'-0"
6 AWNING EAVE DETAIL
A500 0 3'' 6'' 9'' SCALE: 3" = 1'-0"
7 RAKE WALL DETAIL
A500 0 3'' 6'' 9''
SCALE: 1/4" = 1'-0"
1 TYPICAL ROOF PLAN
A500 0 2' 4' 8'
A501
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
8/19/2024
EXISTING NOVELTY COVE
SIDING. REPLACE ANY
DAMAGED OR
DETERIORATED SIDING
WITH NEW MATERIAL AS
REQUIRED. REMOVE
LOOSE CRACKED PAINT,
CLEAN, PRIME AND
PAINT
REPLACE EXISTING WOOD
PANELING IN WALL AND
CEILING WITH NEW
BEADBOARD INTERIOR
PANEL. PRIME AND PAINT 2
COATS
EXISTING
EXISTING WINDOW
HEAD, SCRAPE
LOOSE PAINT,
SAND, CLEAN,
PRIME, AND
PAINT, 2 COATS.
(JAMB SIMILAR)
TOP RAIL OF TOP
SASH,SCRAPE
LOOSE PAINT,
SAND CLEAN
PRIME AND PAINT
2, COATS.
TYPICAL MUNTIN,
SCRAPE LOOSE
PAINT, SAND,
CLEAN, PRIME
AND PAINT, 2
COATS
MEETING RAIL,
SCRAPE LOOSE
PAINT, SAND
CLEAN PRIME AND
PAINT 2, COATS.
BOTTOM RAIL OF
BOTTOM SASH,
SCRAPE LOOSE
PAINT, SAND
CLEAN PRIME AND
PAINT 2, COATS.
WINDOW SILL,
SCRAPE LOOSE
PAINT, SAND
CLEAN PRIME AND
PAINT 2, COATS.
CAREFULLY REMOVE AND
INSTALL NEW GLAZING
CAREFULLY REMOVE AND
INSTALL NEW GLAZING
' M
IN
P.T. 2x4 WOOD RAIL
1/2" PLEXIGLASS
P.T. 2x4 WOOD MULLION
REFINISH FLOORING
P.T. 2x4 WOOD RAIL
1/2" PLEXIGLASS
P.T. 2x4 WOOD MULLION P.T. 2x4 WOOD MULLION
STAINLES STEEL DOOR LATCH
(3 ) STAINLES STEEL DOOR HINGE
P.T. 2x4 WOOD RAIL (BEYOND)
PUBLIC SIDE
EXHIBIT SIDE
2'-10" DOOR 3' 3' 3' 3'
SCALE: 3" = 1'-0"
3 WINDOW DETAIL
A501 0 3'' 6'' 9''
SCALE: 3" = 1'-0"
1 WOOD/ PLEXIGLAS PARTITION HEAD/SILL
A501 0 3'' 6'' 9''
SCALE: 3" = 1'-0"
2 WOOD/ PLEXIGLASS PARTITION JAMB DETAIL
A501 0 3'' 6'' 9''
A502
100% SUBMITTAL
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
169323
10/12/2023
AW
O
O D
LA
N
D , F
LO
RI
D A
M A
RG
O
O D
C O
TT
A
G
ES
R
ES
TO
RA
TIO
N
C O
LL
IE
R C
O
UN
TY
M
US
EU
M S
8/19/2024
1/2"X4" MASONRY
EXPANDING FASTENERS.
S.S
3" S.S. BOLTS WITH
WASHERS AND LOCK
WASHERS
4" S.S. BOLTS WITH
WASHERS AND LOCK
WASHERS
3" S.S. BOLTS WITH
WASHERS AND LOCK
WASHERS
EPOXY GROUT
2" ALUMINIUM RAIL POST
CONCRETE LANDING
3'-6" MINIMUM
'-6
V A R
IE
S
'-1
1'-4"
NEW 2" ALUMINUM PIPE
HANDRAIL RETURN
6X6 POST SET IN
CONCRETE AT LEAST 30"
DEEP X 18" DIA. (TYP)
2X8 P.T. WOOD JOIST
CONCRETE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .