24-127 Addendum (PankowCtr).pdf

PDF 506 KB Posted

Attached to
F. V. Pankow Center - Kitchen Electrical Upgrades
Solicitation number
RFP-LCP-240000003013-2
Issued by
Macomb County, Michigan

About this file

This document is an Addendum for the L'Anse Creuse Public Schools Pankow Kitchen Electrical Upgrades project, Project Number 24-127. The Addendum provides revisions to the Architectural drawings, specifically Sheet A3-01. Key changes include anchoring the existing fixed metal table to the quarry tile floor, adding new under-counter mounted power receptacles, and installing a new electrical power raceway and power pole. The project is located at the F.V. Pankow Center in Clinton Township, Michigan.

The Addendum also includes details for a stainless steel mounting bracket for the new electrical components, with contact information provided for the fabricator. No other salient information, such as pricing, set-asides, or funding sources, is provided in this document.

View the file

Other files

File Type Posted
Electrical Panel.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

L’Anse Creuse Public Schools Pankow Kitchen Electrical Upgrades Addendum No. 1 September 9, 2024

ADDENDUM

Project Name: L’Anse Creuse Public Schools Addendum No: One (1) F. V. Pankow Center - Kitchen Electrical Upgrades

Project Number: 24-127 Issue Date: Sept 9, 2024 Project Location: 24600 Frederick Pankow Blvd, Clinton Twp, MI 48036

This Addendum forms a part of the above-described Contract Documents and supersedes, supplements or clarifies parts thereof to the extent defined by the terms set forth in this Addendum.

This Addendum consists of ( 1 ) typed page(s) and ( 1 ) drawing

DRAWINGS: A3-01

DRAWING REVISIONS:

ARCHITECTURAL:

ITEM A1 Sheet A3-01– Kitchen Floor Plan / Reflected Clg Plan (Revised and Re-Issued in this Addendum)

A. Revise Keynote 2 to read:

a. EXISTING FIXED METAL TABLE (APPROX 9'-0" x 3'-6") TO BE ANCHORED IN PLACE TO

QUARRY TILE FLOOR. PRE-DRILL HOLES FOR ANCHORS. USE ROUND STAINLESS

STEEL FLANGE (TA-19) BY ADVANCE TABCO OR SIMILAR. FIELD VERIFY DIAMETER OF

TABLE LEGS. MINIMUM (2) LEGS TO BE ANCHORED TO FLOOR.

B. Revise Keynote 4 to read:

a. NEW UNDER COUNTER MOUNTED POWER RECEPTACLE (REFER TO ELECTRICAL).

REFER TO DETAIL 4/A3-01 FOR UNDER COUNTER MOUNTING BRACKET DETAIL BY

STAINLESS STEEL FABRICATOR.

C. Add Detail 4 – DUPLEX BRACKET DETAIL (See drawing issued in this addendum)

a. FOR STAINLESS STEEL BRAKET AND WELDING CONTACT:

R & D Fabricating rickdanhausen@gmail.com 248-207-3361

**END OF ADDENDUM**

8'-

±19'-4"

4'

-1

1/ 2"

MOVE EXISTG SS METAL

FREE-STANDING TABLES (2) 6'x30"

TO 4" FROM END HALF WALL.

REMOVE AND RELOCATE EXISTG

MTD KNIFE HOLDER. VERIFY

NEW LOCATION WITH OWNER.

REMOVE AND RELOCATE EXISTG

MTD KNIFE HOLDER. VERIFY NEW

LOCATION WITH OWNER.

EXISTG SINK

NEW ELECTRICAL POWER RACEWAY

FROM POWER POLE. MOUNT 2" ABOVE

BACKSPLASH (REFER TO ELECTRICAL)

EXISTG MASONRY

HALF WALL

4"

NEW POWER POLE MOUNTED TO TOP OF

MASONRY HALF WALL THRU CEILING AND

SUPPORTED TO STRUCTURE ABOVE.

DASHED LINE FOR EXISTG

LOCATION OF SS METAL TABLES

F504

KITCHEN

±4'-6" ±17'-7"±4'-6"±7'-1"

A3-01

1' -6

TY

P)

4' -6

TY

P)

J-BOX BY ELECTRICAL

CONTRACTOR

ELECTRICAL CONDUIT BY

ELECTRICAL CONTRACTOR

STAINLESS STEEL (SS) FABRICATOR TO

PROVIDE AND INSTALL SS MOUNTING

BRACKET FOR J-BOX AND ELECTRICAL

DUPLEX OUTLET WITH FACEPLATE BELOW

EXISTING SS WORK TABLE. COORDINATE

W/ ELECTRICAL CONTRACTOR FOR EXACT

DIMENSIONS.

EXISTING SS WORK TABLE.

VERIFY EDGE DEPTH FOR

BRACKET FABRICATION

GFCI OUTLET AND SS FACE

PLATE BY ELECTRICAL

CONTRACTOR

FOR STAINLESS STEEL BRAKET AND

WELDING CONTACT:

R & D Fabricating rickdanhausen@gmail.com 248-207-3361

Kitchen Floor Plan 1/8" = 1'-0"

A3-01

KITCHEN FLOOR

PLAN / REFLECTED

CEILING PLAN /

INTERIOR ELEVATION

A3-01

Statement of Intellectual Property

The ideas, concepts, drawings and thoughts conveyed herein are the intellectual property of PARTNERS in Architecture, PLC, 65 Market Street, Mount Clemens, MI, 48043 (P 586.469.3600). This set of drawings, in whole or in part, may not be reproduced, without the written consent of PARTNERS in Architecture, PLC. This information is protected under U.S. Copyright Law, all rights reserved.

© Copyright 2024

65 MARKET STREET

MOUNT CLEMENS, MI 48043

P 586.469.3600

PARTNERS in Architecture, PLC

CONSULTANT

OWNER

PROJECT NAME

ISSUES / REVISIONS

DRAWN BY

CHECKED BY

APPROVED BY

SHEET NO.

SHEET NAME

KEY PLAN

PROJECT NO.

L'Anse Creuse Public Schools

F. V. Pankow Center - Kitchen Electrical Upgrades

24600 F. V. Pankow Boulevard Clinton Township, MI 48036

24-127

Bidding - Construction 8/27/2024

CDG

MAM

P:\2024\24-127-LCPS Pankow Ctr Kitchen Elec Upgrades\01_Drawings\A3-01_FLOOR PLAN.dwg - 9/9/2024 2:47:41 PM - Chris Glaspie

THIS DRAWING IS NOT TO BE USED FOR

CONSTRUCTION UNLESS ISSUED BELOW

SPECIFICALLY FOR "BIDDING / CONSTRUCTION"

NORTH

AH

N

A. DO NOT SCALE DRAWINGS. USE DIMENSIONS PROVIDED. IF A

CONFLICT IS ENCOUNTERED OR REQUIRED DIMENSION IS NOT

PROVIDED, REQUEST A CLARIFICATION FROM THE ARCHITECT.

FLOOR PLAN KEY NOTES:

FLOOR PLAN GENERAL NOTES:

NEW POWER POLE TO BE MOUNTED TO FLOOR AND SUPPORTED TO

STRUCTURE ABOVE. CENTER ON SIDE OF TABLE.

(REFER TO ELECTRICAL)

EXISTING FIXED METAL TABLE (APPROX 9'-0" x 3'-6") TO BE

ANCHORED IN PLACE TO QUARRY TILE FLOOR. PRE-DRILL HOLES

FOR ANCHORS. USE ROUND STAINLESS STEEL FLANGE (TA-19) BY

ADVANCE TABCO OR SIMILAR. FIELD VERIFY DIAMETER OF TABLE

LEGS. MINIMUM (2) LEGS TO BE ANCHORED TO FLOOR.

NEW ELECTRIC PANEL (REFER TO ELECTRICAL)

NEW UNDER COUNTER MOUNTED POWER RECEPTACLE. REFER TO

DETAIL 4/A3-01 FOR UNDER COUNTER MOUNTING BRACKET DETAIL

BY STAINLESS STEEL FABRICATOR.

NEW ELECTRICAL RACEWAY MOUNTED TO MASONRY WALL ABOVE

BACKSPLASH. (REFER TO HALF WALL ELEVATION)

NEW LOCATION OF EXISTING FIXED METAL TABLES (2 - 6'-0" x 2'-6")

TO BE ANCHORED IN PLACE WITH ROUND STAINLESS STEEL

FLANGE AND ANCHORS. FIELD VERIFY DIAMETER OF TABLE LEGS.

DASHED LINE FOR EXISTG LOCATION OF SS METAL TABLES

Kitchen Reflected Ceiling Plan 1/8" = 1'-0"

A3-01

Half Wall Elevation 1/4" = 1'-0"

A3-01

Ceiling Symbols Legend

EXISTING 2' X 4' LAY-IN LIGHT FIXTURE IN GRID

EXISTING VENT (MECHANICAL)

EXISTING RECESSED ROUND SPEAKER

EXISTING SPRINKLER

A. DO NOT SCALE DRAWINGS. USE DIMENSIONS PROVIDED. IF A

CONFLICT IS ENCOUNTERED OR REQUIRED DIMENSION IS NOT

PROVIDED, REQUEST A CLARIFICATION FROM THE ARCHITECT.

B. MODIFY EXISTING CEILING GRID AS NECESSARY FOR INSTALATION OF

NEW POWER POLES SUPPORTED UP TO STUCTURE. PATCH AND

REPAIR GRID AND TILES TO LIKE NEW CONDITION.

CEILING PLAN KEY NOTES:

CEILING PLAN GENERAL NOTES:

NEW POWER POLE UP THROUGH SUSPENDED CEILING GRID.

SUPPORT TO STRUCTURE ABOVE. (REFER TO ELECTRICAL)

Duplex Bracket Detail

NOT TO SCALE

A3-01

9/09/2024Addendum-01

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text

VITREOUS CHINA

AutoCAD SHX Text

LAVATORY

AutoCAD SHX Text

GREENWICH

AutoCAD SHX Text K-2031

AutoCAD SHX Text S

File details come from the government source that posted it. Updated .