24-127 Addendum (PankowCtr).pdf
PDF 506 KB Posted
- Solicitation number
- RFP-LCP-240000003013-2
- Issued by
- Macomb County, Michigan
About this file
This document is an Addendum for the L'Anse Creuse Public Schools Pankow Kitchen Electrical Upgrades project, Project Number 24-127. The Addendum provides revisions to the Architectural drawings, specifically Sheet A3-01. Key changes include anchoring the existing fixed metal table to the quarry tile floor, adding new under-counter mounted power receptacles, and installing a new electrical power raceway and power pole. The project is located at the F.V. Pankow Center in Clinton Township, Michigan.
The Addendum also includes details for a stainless steel mounting bracket for the new electrical components, with contact information provided for the fabricator. No other salient information, such as pricing, set-asides, or funding sources, is provided in this document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Electrical Panel.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
L’Anse Creuse Public Schools Pankow Kitchen Electrical Upgrades Addendum No. 1 September 9, 2024
ADDENDUM
Project Name: L’Anse Creuse Public Schools Addendum No: One (1) F. V. Pankow Center - Kitchen Electrical Upgrades
Project Number: 24-127 Issue Date: Sept 9, 2024 Project Location: 24600 Frederick Pankow Blvd, Clinton Twp, MI 48036
This Addendum forms a part of the above-described Contract Documents and supersedes, supplements or clarifies parts thereof to the extent defined by the terms set forth in this Addendum.
This Addendum consists of ( 1 ) typed page(s) and ( 1 ) drawing
DRAWINGS: A3-01
DRAWING REVISIONS:
ARCHITECTURAL:
ITEM A1 Sheet A3-01– Kitchen Floor Plan / Reflected Clg Plan (Revised and Re-Issued in this Addendum)
A. Revise Keynote 2 to read:
a. EXISTING FIXED METAL TABLE (APPROX 9'-0" x 3'-6") TO BE ANCHORED IN PLACE TO
QUARRY TILE FLOOR. PRE-DRILL HOLES FOR ANCHORS. USE ROUND STAINLESS
STEEL FLANGE (TA-19) BY ADVANCE TABCO OR SIMILAR. FIELD VERIFY DIAMETER OF
TABLE LEGS. MINIMUM (2) LEGS TO BE ANCHORED TO FLOOR.
B. Revise Keynote 4 to read:
a. NEW UNDER COUNTER MOUNTED POWER RECEPTACLE (REFER TO ELECTRICAL).
REFER TO DETAIL 4/A3-01 FOR UNDER COUNTER MOUNTING BRACKET DETAIL BY
STAINLESS STEEL FABRICATOR.
C. Add Detail 4 – DUPLEX BRACKET DETAIL (See drawing issued in this addendum)
a. FOR STAINLESS STEEL BRAKET AND WELDING CONTACT:
R & D Fabricating rickdanhausen@gmail.com 248-207-3361
**END OF ADDENDUM**
8'-
±19'-4"
4'
-1
1/ 2"
MOVE EXISTG SS METAL
FREE-STANDING TABLES (2) 6'x30"
TO 4" FROM END HALF WALL.
REMOVE AND RELOCATE EXISTG
MTD KNIFE HOLDER. VERIFY
NEW LOCATION WITH OWNER.
REMOVE AND RELOCATE EXISTG
MTD KNIFE HOLDER. VERIFY NEW
LOCATION WITH OWNER.
EXISTG SINK
NEW ELECTRICAL POWER RACEWAY
FROM POWER POLE. MOUNT 2" ABOVE
BACKSPLASH (REFER TO ELECTRICAL)
EXISTG MASONRY
HALF WALL
4"
NEW POWER POLE MOUNTED TO TOP OF
MASONRY HALF WALL THRU CEILING AND
SUPPORTED TO STRUCTURE ABOVE.
DASHED LINE FOR EXISTG
LOCATION OF SS METAL TABLES
F504
KITCHEN
±4'-6" ±17'-7"±4'-6"±7'-1"
A3-01
1' -6
TY
P)
4' -6
TY
P)
J-BOX BY ELECTRICAL
CONTRACTOR
ELECTRICAL CONDUIT BY
ELECTRICAL CONTRACTOR
STAINLESS STEEL (SS) FABRICATOR TO
PROVIDE AND INSTALL SS MOUNTING
BRACKET FOR J-BOX AND ELECTRICAL
DUPLEX OUTLET WITH FACEPLATE BELOW
EXISTING SS WORK TABLE. COORDINATE
W/ ELECTRICAL CONTRACTOR FOR EXACT
DIMENSIONS.
EXISTING SS WORK TABLE.
VERIFY EDGE DEPTH FOR
BRACKET FABRICATION
GFCI OUTLET AND SS FACE
PLATE BY ELECTRICAL
CONTRACTOR
FOR STAINLESS STEEL BRAKET AND
WELDING CONTACT:
R & D Fabricating rickdanhausen@gmail.com 248-207-3361
Kitchen Floor Plan 1/8" = 1'-0"
A3-01
KITCHEN FLOOR
PLAN / REFLECTED
CEILING PLAN /
INTERIOR ELEVATION
A3-01
Statement of Intellectual Property
The ideas, concepts, drawings and thoughts conveyed herein are the intellectual property of PARTNERS in Architecture, PLC, 65 Market Street, Mount Clemens, MI, 48043 (P 586.469.3600). This set of drawings, in whole or in part, may not be reproduced, without the written consent of PARTNERS in Architecture, PLC. This information is protected under U.S. Copyright Law, all rights reserved.
© Copyright 2024
65 MARKET STREET
MOUNT CLEMENS, MI 48043
P 586.469.3600
PARTNERS in Architecture, PLC
CONSULTANT
OWNER
PROJECT NAME
ISSUES / REVISIONS
DRAWN BY
CHECKED BY
APPROVED BY
SHEET NO.
SHEET NAME
KEY PLAN
PROJECT NO.
L'Anse Creuse Public Schools
F. V. Pankow Center - Kitchen Electrical Upgrades
24600 F. V. Pankow Boulevard Clinton Township, MI 48036
24-127
Bidding - Construction 8/27/2024
CDG
MAM
P:\2024\24-127-LCPS Pankow Ctr Kitchen Elec Upgrades\01_Drawings\A3-01_FLOOR PLAN.dwg - 9/9/2024 2:47:41 PM - Chris Glaspie
THIS DRAWING IS NOT TO BE USED FOR
CONSTRUCTION UNLESS ISSUED BELOW
SPECIFICALLY FOR "BIDDING / CONSTRUCTION"
NORTH
AH
N
A. DO NOT SCALE DRAWINGS. USE DIMENSIONS PROVIDED. IF A
CONFLICT IS ENCOUNTERED OR REQUIRED DIMENSION IS NOT
PROVIDED, REQUEST A CLARIFICATION FROM THE ARCHITECT.
FLOOR PLAN KEY NOTES:
FLOOR PLAN GENERAL NOTES:
NEW POWER POLE TO BE MOUNTED TO FLOOR AND SUPPORTED TO
STRUCTURE ABOVE. CENTER ON SIDE OF TABLE.
(REFER TO ELECTRICAL)
EXISTING FIXED METAL TABLE (APPROX 9'-0" x 3'-6") TO BE
ANCHORED IN PLACE TO QUARRY TILE FLOOR. PRE-DRILL HOLES
FOR ANCHORS. USE ROUND STAINLESS STEEL FLANGE (TA-19) BY
ADVANCE TABCO OR SIMILAR. FIELD VERIFY DIAMETER OF TABLE
LEGS. MINIMUM (2) LEGS TO BE ANCHORED TO FLOOR.
NEW ELECTRIC PANEL (REFER TO ELECTRICAL)
NEW UNDER COUNTER MOUNTED POWER RECEPTACLE. REFER TO
DETAIL 4/A3-01 FOR UNDER COUNTER MOUNTING BRACKET DETAIL
BY STAINLESS STEEL FABRICATOR.
NEW ELECTRICAL RACEWAY MOUNTED TO MASONRY WALL ABOVE
BACKSPLASH. (REFER TO HALF WALL ELEVATION)
NEW LOCATION OF EXISTING FIXED METAL TABLES (2 - 6'-0" x 2'-6")
TO BE ANCHORED IN PLACE WITH ROUND STAINLESS STEEL
FLANGE AND ANCHORS. FIELD VERIFY DIAMETER OF TABLE LEGS.
DASHED LINE FOR EXISTG LOCATION OF SS METAL TABLES
Kitchen Reflected Ceiling Plan 1/8" = 1'-0"
A3-01
Half Wall Elevation 1/4" = 1'-0"
A3-01
Ceiling Symbols Legend
EXISTING 2' X 4' LAY-IN LIGHT FIXTURE IN GRID
EXISTING VENT (MECHANICAL)
EXISTING RECESSED ROUND SPEAKER
EXISTING SPRINKLER
A. DO NOT SCALE DRAWINGS. USE DIMENSIONS PROVIDED. IF A
CONFLICT IS ENCOUNTERED OR REQUIRED DIMENSION IS NOT
PROVIDED, REQUEST A CLARIFICATION FROM THE ARCHITECT.
B. MODIFY EXISTING CEILING GRID AS NECESSARY FOR INSTALATION OF
NEW POWER POLES SUPPORTED UP TO STUCTURE. PATCH AND
REPAIR GRID AND TILES TO LIKE NEW CONDITION.
CEILING PLAN KEY NOTES:
CEILING PLAN GENERAL NOTES:
NEW POWER POLE UP THROUGH SUSPENDED CEILING GRID.
SUPPORT TO STRUCTURE ABOVE. (REFER TO ELECTRICAL)
Duplex Bracket Detail
NOT TO SCALE
A3-01
9/09/2024Addendum-01
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text
LAVATORY
AutoCAD SHX Text
GREENWICH
AutoCAD SHX Text K-2031
AutoCAD SHX Text S
File details come from the government source that posted it. Updated .