24-11037-000_Addendum_1_Approved_Drawings.pdf

PDF 23 MB Posted

Attached to
24-11037-000 Fuel Service Equipment Replacement
Solicitation number
0000035341
Issued by
San Luis Obispo County, Anaheim City, San Luis Obispo City, California

About this file

The documents are construction drawings for a Fuel Service Equipment Replacement project for the Department of State Hospitals (DSH) at the Atascadero campus, located at 10333 El Camino Real, Atascadero, California. The project involves demolishing the existing fuel service equipment refill station and installing a new fuel management system for fleet vehicles, specifically for E-10 fuel. The scope includes mechanical and electrical work such as removing existing fuel service equipment, providing new fuel management system components, installing power and controls, and adding a convenience receptacle.

The project is designed with careful attention to fire safety and code compliance, utilizing 2022 California building, electrical, mechanical, and fire codes. The total project area is 425 square feet, with the work focused on Building S-17, a Type I-A construction building. The electrical and mechanical systems will be updated to support the new fuel service equipment, with specific requirements for conduit, wiring, and equipment installation. The project includes detailed specifications for equipment such as a Fuel Master Live Pedestal, tank gauging system, fuel dispenser, transfer pump, and associated electrical components.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T0.1

TITLE SHEET

Checked

Vault File Number

Project Number

Reference North Sheet Scale

Sheet Number

Designed

Sheet Title

Supervisor

Issue Date

Drawn

Project

Description

No.

Date Issue

JCCA #: 24791-8

00000000000XXXX

DEPARTMENT OF STATE

HOSPITALS - ATASCADERO

DEPARTMENT OF

STATE HOSPITALS

(DSH)

AS SHOWN

DSA STAMP

FUEL SERVICE

EQUIPMENT

REPLACEMENT

DSH

10/25/2024

100% SUBMITTAL

Client Agency

DEPARTMENT OF STATE HOSPITALS

385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501

P: 310.212.7644 F:310.212.5272I

JCCA

D A T E T

IM

E F e b ru a ry

:4

P

M

F

IL

E L \2

-8

F u e l S e rv ic e E q u ip m e n t R e p la c e m e n t, D

S H

-A \C

A D

\2 T

10333 EL CAMINO REAL, ATASCADERO, CALIFORNIA 93422

DEPARTMENT OF STATE HOSPITALS - ATASCADERO

DEPARTMENT OF STATE HOSPITALS

1. CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER 33 -

FIRE SAFETY DURING CONSTRUCTION OF THE 2022 CALIFORNIA FIRE CODE.

FIRE SAFETY DURING CONSTRUCTION

REFERENCE: 2022 CALIFORNIA FIRE CODE

1. SEE OVERALL SITE PLAN FOR SITE ACCESS FOR BOTH PUBLIC RIGHT OF WAY

AND DSH FIRE DEPARTMENT.

FIRE APPARATUS ACCESS

FUEL SERVICE EQUIPMENT REPLACEMENT

OSFM PERMIT NUMBER: 24-N-4811

PROJECT INFORMATION

PREPARED BY:

J.C. CHANG & ASSOCIATES, INC.

ENGINEERS, ARCHITECTS AND PLANNERS

385 VAN NESS AVENUE, SUITE 208

TORRANCE, CALIFORNIA 90501

PHONE : (310) 212-7644

PROJECT ENGINEER

BEN STEFFES

385 VAN NESS AVE. #208

TORRANCE, CALIFORNIA 90501

ARCHITECT OF RECORD/

PRIMARY PROFESSIONAL

RICHARD DE LA FUENTE

LIC. NO. C-33965

385 VAN NESS AVE. #208

TORRANCE, CALIFORNIA 90501

MECHANICAL ENGINEER OF RECORD

ROBERT NOLAN

LIC. NO. 31684

385 VAN NESS AVE. #208

TORRANCE, CALIFORNIA 90501

ELECTRICAL ENGINEER OF RECORD

SEVAG AVANESSIAN

LIC. NO. E22793

385 VAN NESS AVE. #208

TORRANCE, CALIFORNIA 90501

DRAWING INDEX

STATE FIRE MARSHAL SPECIAL INSPECTIONS

A MINIMUM OF 72 HOURS NOTICE WILL BE PROVIDED TO THE STATE FIRE MARSHAL

WHEN SCHEDULING ANY TESTS OR INSPECTIONS.

1. DUCT, CONDUIT OR PIPE PENETRATIONS INSPECTIONS THRU FIRE RATED

ASSEMBLIES.

APPLICABLE CODES AND STANDARDS

1. 2022 BUILDING STANDARDS ADMINISTRATIVE CODE, PART 1, TITLE 24 C.C.R.

2. 2022 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 C.C.R.

(2021 INTERNATIONAL BUILDING CODE & 2021 CALIFORNIA AMENDMENTS)

3. 2022 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R.

(2021 NATIONAL ELECTRICAL CODE AND 2021 CALIFORNIA AMENDMENTS)

4. 2022 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 C.C.R.

(2022 UNIFORM MECHANICAL CODE AND 2022 CALIFORNIA AMENDMENTS)

5. 2022 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R.

(2022 UNIFORM PLUMBING CODE AND 2022 CALIFORNIA AMENDMENTS)

6. 2022 CALIFORNIA ENERGY CODE (CEC), PART 6, TITLE 24 C.C.R.

7. 2022 CALIFORNIA FIRE CODE, PART 9, TITLE 24 C.C.R.

(2022 INTERNATIONAL FIRE CODE AND 2022 CALIFORNIA AMENDMENTS)

8. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN), PART 11,

TITLE 24 C.C.R.

9. 2022 CALIFORNIA REFERENCED STANDARDS, PART 12, TITLE 24 C.C.R.

10. TITLE 19 C.C.R., PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS.

PARTIAL LIST OF APPLICABLE STANDARDS

1. NFPA 1 FIRE CODE, CHAPTER 42 - REFUELING 2022 EDITION

2. NFPA 13 AUTOMATIC SPRINKLER SYSTEMS (CA AMENDED) 2022 EDITION

3. NFPA 14 STANDPIPE SYSTEM (CA AMENDED) 2019 EDITION

4. NFPA 17a WET CHEMICAL SYSTEMS 2021 EDITION

5. NFPA 20 STATIONARY PUMPS 2019 EDITION

6. NFPA 24 PRIVATE FIRE MAINS (CA AMENDED) 2019 EDITION

7. NFPA 30A CODE FOR MOTOR FUEL DISPENSING FACILITIES 2022 EDITION

AND REPAIR GARAGES

8. NFPA 72 NATIONAL FIRE ALARM CODE (CA AMENDED) 2022 EDITION

9. NFPA 2001 CLEAN AGENT FIRE EXTINGUISHING SYSTEMS 2018 EDITION

W/ CA AMENDMENTS

10. NFPA 101 LIFE SAFETY CODE 2021 EDITION

11. REFERENCE CODE SECTION FOR NFPA STANDARDS 2022 CBC (SFM)

CHAPTER 35

REFERENCE CODE SECTION FOR NFPA STANDARDS ARE IN 2022 CBC CHAPTER 35

OR 2022 CFC CHAPTER 80. SEE CHAPTER 35 FOR STATE OF CALIFORNIA

AMENDMENTS TO NFPA STANDARDS

MECHANICAL SCOPE:

1. DEMOLISH EXISTING FUEL SERVICE EQUIPMENT REFILL STATION.

2. PROVIDE NEW FUEL SERVICE EQUIPMENT FUEL MANAGEMENT SYSTEM FOR

FLEET VEHICLES ONLY, E-10 FUEL.

ELECTRICAL SCOPE:

1. DEMOLISH ELECTRICAL PROVISIONS FOR FUEL SERVICE EQUIPMENT.

2. PROVIDE POWER AND CONTROLS TO NEW FUEL SERVICE MANAGEMENT

SYSTEM.

3. PROVIDE CONVENIENCE RECEPTACLE.

1. NO DEFERRED APPROVAL ON THIS PROJECT

DEFERRED APPROVALS

N

N

SCOPE OF WORK (NOT LIMITED TO)VICINITY MAPSITE PLAN

PROJECT

LOCATION

MUSSELM

AN D

R.

SAN RAFAEL R

D

EL B

ORDO

SAN RAFAEL RD

H

AL

C O N R

D

LO

S P

UEBLO

S

HEILMANN

REGIONAL

PARK

LOS LOMAS VILLAGE

SAN RAFAEL RDS

A N R

A F A E L R

D

W F

R O N T R

D

E L C

A M

IN

O R

E A L

PREPARED FOR:

DEPARTMENT OF STATE HOSPITALS -

ATASCADERO

10333 EL CAMINO REAL

ATASCADERO, CALIFORNIA 93422

DEPARTMENT OF STATE HOSPITALS

1215 O ST., 2ND FLOOR

SACRAMENTO, CALIFORNIA 95814

RANDY DYE

CHIEF OF PLANT OPERATIONS III

10333 EL CAMINO REAL

ATASCADERO CA 93422

DESK: (805) 468-2206

CELL: (805) 712-6733

EMAIL: RANDY.DYE@DSH.CA.GOV

SHEET NUMBER SHEET TITLE

GENERAL

T0.1 TITLE SHEET

T0.2 FIRE ACCESS SITE PLAN

T0.3 STATE FIRE MARSHALL TRIAGE LIST

T0.4 BUILDING INFORMATION

MECHANICAL

M0.1 MECHANICAL COVER SHEET

M0.2 MECHANICAL SCHEDULES

M1.1 MECHANICAL DEMOLITION PLAN

M2.1 MECHANICAL NEW WORK PLAN

M3.1 MECHANICAL DETAILS

ELECTRICAL

E0.1 ELECTRICAL COVER SHEET

E0.2 ELECTRICAL PANEL SCHEDULE A

E1.1 ELECTRICAL DEMOLITION SITE PLAN

E2.1 ELECTRICAL NEW WORK SITE PLAN

E2.2

BUILDING 810 AND 850 ELECTRICAL POWER NEW WORK

FLOOR PLANS

E3.1 ELECTRICAL DETAILS

REFERENCE

R1.1 ENLARGED SITE PLAN

R1.2 REFERENCE SHEET

R1.3 REFERENCE SHEET

R2.1 REFERENCE SHEET

R3.1 REFERENCE PHOTOS

TOTAL NUMBER OF SHEETS = 20

BUILDING DATA

OCCUPANCY CLASSIFICATION AND USE U

(OUTDOOR

STORAGE AREA)

BUILDING CONSTRUCTION TYPE I-A

NUMBER OF STORIES 1

ACTUAL BUILDING HEIGHT 13 FT

BUILDING AREA IN SQUARE FEET 425 GSF

(TOTAL BUILDING, ALL FLOORS)

AREA OF PROJECT IN SQUARE FEET 425 SF

(TOTAL AREA)

SEPARATED OR NON-SEPARATED USE NON-SEPARATED

ALLOWABLE AREA PER C.B.C. UL

AREA INCREASE NO

HEIGHT INCREASE NO

FIRE SPRINKLERS NO

(YES,NO)

FIRE SPRINKLERS TYPE N/A

(WET, DRY, PRE-ACTION, OR DELUGE)

FIRE ALARM NO

(YES/NO)

FIRE ALARM TYPE N/A

(MANUAL, AUTOMATIC, EVAC, ETC.)

OTHER FIRE PROTECTION NO

(YES OR NO)

SMOKE CONTROL SYSTEM NO

(YES OR NO)

OCCUPANT LOAD FOR ENTIRE BUILDING N/A

(AND EACH FLOOR)

YEAR BUILDING WAS CONSTRUCTED 1969

IS BUILDING IN HIGH SEVERITY FIRE ZONE NO

(YES OR NO)

SEISMIC JOINTS NO

(YES OR NO)

SEISMIC JOINT LOCATION N/A

EMERGENCY RESPONDER RADIO COVERAGE YES

RISK CATEGORY PER 2022 CBC CHAPTER 16 II

BUILDING DATA - BLDG# S-17

V2

OFFICE OF THE STATE FIRE MARSHAL

shall be available on the project site at all times.

03/04/25

APPROVED FIRE AND PANIC ONLY

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans

24-4811

Jeremy Willett. JCCA Thu Feb 20 12:02:49 2025: V2

503A

532 531

CS-40

546 542

510A

504A

505A

5B

5A

506A

508A

MB-104

MB-107

MB-103

MB-101

607 606

509B

508B

506B

B

305304

503B

502B

501B 510B

S-16

512A

(110A)

S-8

SB-2

SB-3

MB-102

CS-35 - CS-37

SB-1

CS-25

CS-38

SB-5

CS-39

S-18 S-19

S-7

CS

-23

CS

-24

SB-4

CS-17 CS-31

&CS-32

CS-1 - CS-16

CS-18 - CS-22

S-17

CS-33 & CS-34

S-1

S-3 S-2

S-4

S-5

S-15

509A

S-10

S-12

S-13

S-11

S-9 511A

CS-26

-CS-30

B

S-6

510C

502A

T0.2

FIRE ACCESS SITE PLAN

Checked

Vault File Number

Project Number

Reference North Sheet Scale

Sheet Number

Designed

Sheet Title

Supervisor

Issue Date

Drawn

Project

Description

No.

Date Issue

JCCA #: 24791-8

00000000000XXXX

DEPARTMENT OF STATE

HOSPITALS - ATASCADERO

DEPARTMENT OF

STATE HOSPITALS

(DSH)

AS SHOWN

DSA STAMP

FUEL SERVICE

EQUIPMENT

REPLACEMENT

DSH

10/25/2024

100% SUBMITTAL

Client Agency

DEPARTMENT OF STATE HOSPITALS

385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501

P: 310.212.7644 F:310.212.5272I

JCCA

D A T E T

IM

E M a rc h

:0

P

M

F

IL

E L \2

-8

F u e l S e rv ic e E q u ip m e n t R e p la c e m e n t, D

S H

-A \C

A D

\2 T

FIRE ACCESS SITE PLAN

NO TO SCALE

N

SITE ACCESS FROM PUBLIC

RIGHT OF WAY AND USING

EXISTING PAVED ROADS

BLDG 908

FIRE DEPARTMENT

BUILDING NAME

S-17 FUEL STATION

908 FIRE DEPARTMENT

810 MAINTENANCE SHOP

820 GARAGE

850 PAINT SHOP

EXISTING PAVED ROAD

IS MIN. 25' WIDE

EXISTING PAVED

ROAD IS MIN. 20' WIDE

TURNING RADIUS = 53'

SALLY PORT

LEGEND:

FIRE TRUCK ROUTE

FIRE HYDRANT

IDENTIFIED EXISTING

RED CURB MARKING

RED CURB/SIGNAGE WITHIN THE

AREA OF WORK , AS NOTED.

V2

OFFICE OF THE STATE FIRE MARSHAL

shall be available on the project site at all times.

03/04/25

APPROVED FIRE AND PANIC ONLY

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans

T0.3

STATE FIRE MARSHALL

TRIAGE LIST

Checked

Vault File Number

Project Number

Reference North Sheet Scale

Sheet Number

Designed

Sheet Title

Supervisor

Issue Date

Drawn

Project

Description

No.

Date Issue

JCCA #: 24791-8

00000000000XXXX

DEPARTMENT OF STATE

HOSPITALS - ATASCADERO

DEPARTMENT OF

STATE HOSPITALS

(DSH)

AS SHOWN

DSA STAMP

FUEL SERVICE

EQUIPMENT

REPLACEMENT

DSH

10/25/2024

100% SUBMITTAL

Client Agency

DEPARTMENT OF STATE HOSPITALS

385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501

P: 310.212.7644 F:310.212.5272I

JCCA

D A T E T

IM

E J a n u a ry

:3

P

M

F

IL

E L \2

-8

F u e l S e rv ic e E q u ip m e n t R e p la c e m e n t, D

S H

-A \C

A D

\2 T

ITEM SUBMITTAL REQUIREMENTS SUBMITTAL RESPONSE REFERENCE

GENERAL

SEE FOR SPECIFIC SECTION COMMENTS NOT APPLICABLE

PROVIDE A COMPLETE PLAN REVIEW APPLICATION

SUBMIT PLANS SUFFICIENT SIZE

PROVIDE SITE ADDRESS

PROVIDE NAME OF OWNER AND OCCUPANT

IDENTIFY IF NEW CONSTRUCTION OR T.I

IDENTIFY IF NEW OR EXISTING TENANT SPACE

IDENTIFY IF DEFERRED SUBMITTAL

ADD OSFM FILE NUMBER TO TITLE SHEET

PROJECT IS A PHASED SUBMITTAL

SLIP SHEETS SHALL BE BOUND TO SET

SHEET INDEX

WET STAMP AND SIGN SHEETS

SCOPE OF WORK

PROVIDED WITH SUBMITTAL

FLOOR PLANS ARE 1/8"=1' MINIMUM

10333 EL CAMINO REAL, ATASCADERO, CALIFORNIA 93422

OWNER: DEPARTMENT OF STATE HOSPITAL

T.I.

EXISTING

ALL RELEVANT

SHEETS

NOT APPLICABLE

T0.1

T0.1

OSFM NO IS NOTED ON THE TITLE SHEET T0.1

PROJECT IS NOT PHASED

NOT APPLICABLE

SHEET INDEX IS ON T0.1 T0.1

ELECTRONIC SIGNATURE PROVIDED ON DOCUMENT ALL SHEETS

SCOPE OF WORK IS INCLUDED ON TITLE SHEET T0.1

OCCUPANT: DEPARTMENT OF STATE HOSPITAL

PROVIDE A KEY PLAN COORDINATED TO EACH SHEET

PROVIDE A NORTH ORIENTED SITE MAP

ORIENTATE ALL SHEETS TO NORTH

PROVIDE ADOPTED CODE CYCLE LISTINGS AND STANDARDS

PROVIDE A LEGIBLE SCALE. TYPICALLY 1/8"

PROVIDE APPROVED REFERENCE PLANS/DOCUMENTATION

SITE KEY PLAN IS PROVIDED

NORTH ORIENTED SITE PLAN IS PROVIDED T0.3

SITE PLAN IS ORIENTED TO NORTH, INDIVIDUAL DRAWINGS HAVE KEYPLAN

ALL RELEVANT

SHEETS

ADOPTED CODE CYCLE LISTINGS ARE INCLUDED ON TITLE SHEET

ALL FLOOR PLANS ARE 1/8" SCALE MINIMUM. ALL SITE PLANS ARE 1"=30'

NOT APPLICABLE

T0.1

ALL RELEVANT

SHEETS

ALL RELEVANT

SHEETS

V2

OFFICE OF THE STATE FIRE MARSHAL

shall be available on the project site at all times.

03/04/25

APPROVED FIRE AND PANIC ONLY

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans

Jeremy Willett. JCCA Thu Feb 20 12:02:51 2025: V2

14'-6 5/8" 17'-5 9/16"

T0.4

BUILDING INFORMATION

Checked

Vault File Number

Project Number

Reference North Sheet Scale

Sheet Number

Designed

Sheet Title

Supervisor

Issue Date

Drawn

Project

Description

No.

Date Issue

JCCA #: 24791-8

00000000000XXXX

DEPARTMENT OF STATE

HOSPITALS - ATASCADERO

DEPARTMENT OF

STATE HOSPITALS

(DSH)

AS SHOWN

DSA STAMP

FUEL SERVICE

EQUIPMENT

REPLACEMENT

DSH

10/25/2024

100% SUBMITTAL

Client Agency

DEPARTMENT OF STATE HOSPITALS

385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501

P: 310.212.7644 F:310.212.5272I

JCCA

D A T E T

IM

E F e b ru a ry

:5

A

M

F

IL

E L \2

-8

F u e l S e rv ic e E q u ip m e n t R e p la c e m e n t, D

S H

-A \C

A D

\2 T

BUILDING INFORMATION

BUILDING

NAME

CONSTRUCTION

TYPE

ACTUAL NUMBER OF

STORIES / (STORIES

ALLOWED CBC 504.4)

ACTUAL

BUILDING AREA

(AREA ALLOWED

CBC 506.2 )

SEPARATED /

NON - SEPARATED

SPRINKLER

COVERAGE

FIRE

ALARM

OTHER

PROTECTION

SYSTEM

SMOKE

CONTROL

SYSTEM

OCCUPANT

LOAD

YEAR BUILDING

CONSTRUCTED

SEISMIC

JOINT

OCCUPANCY

CLASS

S-17 N/A N/A NONE NO

BUILDING

HEIGHT

NONE N/A NONE NO NO NOTYPE 1

U

OUTDOOR

STORAGE AREA

+/-13'-0"

(N/A)

EMERGENCY

RESPONDER

RADIO

COVERAGE

HIGH FIRE

HAZARD

SEVERITY

ZONE

(1)

SITE PLAN

SCALE: N

810 39 1954 NO NO YESII-B NON-SEPARATED YES

STANDPIPES AND

FIRE EXTINGUISHERS

NO

(3)

19,110 (70,000)

+/-20'-0"

S-1

(MANITENANCE

SHOPS)

AREA OF

PROJECT

AREA

INCREASE

NO

HEIGHT

INCREASE

NO

NO

HIGH-RISE

NO

NONO NO

(E) S-17 CANOPY

BLDG 810 (UPPER) &

BLDG 850 (LOWER)

0 81 FEET4

1/4" = 1'-0"

850 100 1989 NO NO YESII-B NON-SEPARATED YES

STANDPIPES AND

FIRE EXTINGUISHERS

NO

(3)

3,000 (N/A)

+/-20'-0"

S-1

(MAINTENANCE

SHOPS)

- NO NONO NO

(E) FUEL DISPENSING SYSTEM

(E) ABOVE GROUND FUEL STORAGE

TANK.

S-17 REFUELING - GENERAL REQUIREMENTS

FUEL

AREA

TYPE AND

DESIGN

FUEL DISPENSER:

LOCATION AND

DESIGN

DISTANCE:

DISPENSER TO

PROPERTY LINE

VEHICLE ACCESS

METHODS:

STORAGE AND

DISPENSING

OVERFILL

PREVENTION

VENTS

VAPOR

RECOVERY

PIPING, VALVES, AND

FITTINGS

SPECIFICATIONS

ELECTRICAL

EQUIPMENT

UNDERGROUND/

ABOVEGROUND

S-17 SEE M0.2 SEE E2.1 & E2.2

DISTANCE:

TANK TO

DISPENSER

SEE R1.1 SEE M0.2 & M2.1

SEE DISPENSER

SPECIFICATIONS

SEE VENTS ON M2.1

SEE LOCATION

ON M2.1

SEE M0.2 ABOVEGROUND +/- 1'-0" +/- 764'-9"

TANK MOUNTED

DISPENSER BEHIND

FENCE OF S-17

DISTANCE:

DISPENSER TO

ADJACENT

BUILDING

+/- 14'-6 5/8"

FIRE

APPLIANCES

SEE R1.1

VEHICLE

IMPACT

PROTECTION

SEE R1.1

(E) PEDESTRIAN GATE

(E) PEDESTRIAN GATE

(E) CHAIN-LINK FENCE

(E) S-17 CANOPY COLUMN, TYP.

(E) WALL

(E) STAIRS

CS-33 - NO NO NO YESNON-SEPARATED NO NO NO

(3) (N/A)

+/-9'-0" U

METAL STORAGE

SHED

- NO NONO NO

CS-34

II-B

II-B

U

METAL STORAGE

SHED

(3) +/-9'-0"

CS-34CS-33

(N/A)

- NON-SEPARATED NONO NO NO - NO NO NO YESNO NONO

V2

OFFICE OF THE STATE FIRE MARSHAL

shall be available on the project site at all times.

03/04/25

APPROVED FIRE AND PANIC ONLY

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans

M0.1

MECHANICAL COVER SHEET

Checked

Vault File Number

Project Number

Reference North Sheet Scale

Sheet Number

Designed

Sheet Title

Supervisor

Issue Date

Drawn

Project

Description

No.

Date Issue

JCCA #: 24791-8

00000000000XXXX

DEPARTMENT OF STATE

HOSPITALS - ATASCADERO

DEPARTMENT OF

STATE HOSPITALS

(DSH)

AS SHOWN

DSA STAMP

FUEL SERVICE

EQUIPMENT

REPLACEMENT

DSH

10/25/2024

100% SUBMITTAL

Client Agency

DEPARTMENT OF STATE HOSPITALS

385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501

P: 310.212.7644 F:310.212.5272I

JCCA

D A T E T

IM

E F e b ru a ry

:2

P

M

F

IL

E L \2

-8

F u e l S e rv ic e E q u ip m e n t R e p la c e m e n t, D

S H

-A \C

A D

\2 M

POINT OF DISCONNECTION

SHEET WHERE DETAIL IS DRAWN

ROOM THERMOSTATT

DETAIL NO.

NEW WORK KEY NOTE

DEMOLITION KEY NOTE

POINT OF CONNECTION

EXHAUST

CUBIC FEET PER

ABOVE FLOOR

ACCESS DOOR

GALLONS PER MINUTE

GAUGEGA.

GPM

EXH.

A.D.

A.F.

CFM

FIRE SPRINKLER LINE

FUEL OIL SUPPLY

FUEL OIL RETURN

VENT

F

FOS

FOR

V

SYMBOL DESCRIPTION

CONTROL VALVE

M MOTOR ACUATED MODULATING

SYMBOL

S

A

PUMP

P

PRESSURE RELIEF

AUTOMATIC AIR VENT

PETE'S PLUG

PRESSURE GAUGE

THERMOMETER

PNEUMATIC ACTUATED

SOLENOID ACTUATED

PRESSURE REGULATOR

ANGLE VALVE

CHECK VALVE

VENTURI FLOW METER

PLUG VALVE

GAS VALVE

STRAINER

GLOBE VALVE

BUTTERFLY VALVE

DESCRIPTION

GATE VALVE

BALL VALVE

MECHANICAL PIPING SYMBOLS

MINUTE

EXISTING TO REMAIN, PROTECT IN PLACE(E)

OPENING

PLATFORM

OPNG.

PLAT.

POINT OF DISCONNECTPOD

NEW, PROVIDE AND INSTALL(N)

MECHANICAL ABBREVIATIONS

POINT OF CONNECTIONPOC

CONDENSER WATER SUPPLYCWS

CONDENSER WATER RETURNCWR

CONDENSER WATERCW

BUILDING MANAGEMENT SYSTEMB.M.S.

DEMOLITION/ DEMOLISH(D)

GENERAL NOTES MECHANICAL SYMBOLS

1. THE CONTRACTOR SHALL FURNISH ALL LABOR, SUPERVISION, MATERIALS,

EQUIPMENT, TOOLS, TRANSPORTATION, WAREHOUSING, AND ANY OTHER

SERVICES REQUIRED TO COMPLETE THE WORK IN A TIMELY AND EFFICIENT

MANNER.

2. INDIVIDUAL ITEMS OF WORK ARE DETAILED IN THE VARIOUS SECTIONS OF THIS

SCOPE OF WORK, THE ATTACHED DRAWINGS, AND THE NOTES AND LEGENDS

ON THE DRAWINGS. THE CONTRACTOR IS RESPONSIBLE TO COMPLETE THE

REQUIREMENTS FOUND IN ANY OF THE ABOVE.

3. CONTRACTOR BIDS ARE TO BE BASED UPON COMPLETING THE WORK WITHIN

THE AMOUNT BID. ANY QUESTIONS PERTAINING TO UNKNOWN CONDITIONS,

CHANGES IN DESIGN, OMISSIONS IN THE DESIGN OR SCOPE OF WORK,

MATERIALS, AND INSTALLATION TECHNIQUE ARE TO BE DISCUSSED WITH THE

PROJECT MANAGER. THE PROJECT MANAGER WILL GET THE ANSWERS TO

QUESTIONS, AS SOON AS POSSIBLE, IF "ON-THE-SPOT" ANSWERS CAN NOT BE

PROVIDED. UNKNOWN CONDITIONS ENCOUNTERED DURING THE COURSE OF

WORK, WHICH MAY DELAY WORK OR ADD COST, WILL BE REPORTED TO THE

PROJECT MANAGER IMMEDIATELY-SO THAT PROPER ARRANGEMENTS CAN BE

MADE WITHOUT WORK STOPPAGE.

4. ALL WORK SHALL BE IN COMPLIANCE WITH THE EDITION OF THE OWNERS

STANDARDS AND REQUIREMENTS CURRENTLY IN FORCE AND ALL LOCAL

ORDINANCES AND REQUIREMENTS.

5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL ALL

TEMPORARY BRACING AND SHORING OF EQUIPMENTS TO INSURE THE SAFETY

OF THE WORK UNTIL IT IS IN ITS COMPLETED FORM.

6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT ALL

APPLICABLE SAFETY LAWS ARE STRICTLY ENFORCED AND TO MAINTAIN A

SAFE CONSTRUCTION PROJECT.

7. THE CONTRACTOR SHALL REPAIR AND/OR REPAINT ALL AREAS DAMAGED BY

DEMOLITION OR CONSTRUCTION, AND FINISH TO MATCH EXISTING ADJACENT

SURFACES.

8. DAILY, AND UPON COMPLETION OF WORK, CONTRACTOR SHALL REMOVE

DEBRIS, RUBBISH, WASTE, AND SURPLUS MATERIAL FROM THE PREMISES.

9. THE CONTRACTOR SHALL PROTECT AND COVER ALL FIXTURES AND

EQUIPMENT IN AREAS AFFECTED BY WORK, AND UPON COMPLETION OF WORK,

SHALL THOROUGHLY CLEAN ALL FIXTURES, EQUIPMENT, WALLS, CEILING,

FLOOR, AND HARDWARE.

10. ALL PERMITS SHALL BE OBTAINED AS REQUIRED BY LOCAL CODES AND AHJ.

11. CONTRACTOR SHALL VERIFY ALL INDOOR/OUTDOOR DIMENSIONS AND

OUTDOOR JOB CONDITIONS AT THE JOB SITE PRIOR TO BID, DO NOT SCALE

DRAWINGS.

12. CONTRACTOR SHALL PROVIDE ALL PLAN CHECK SERVICES, WHERE

APPLICABLE.

13. CONTRACTOR SHALL OBTAIN A BURN PERMIT FOR ALL HOT WORK FROM FIRE

PREVENTION COORDINATOR.

14. FOR PURPOSES OF CLEARNESS AND LEGIBILITY, THE CONTRACT DRAWINGS

ARE ESSENTIALLY DIAGRAMMATIC AND, ALTHOUGH LOCATION OF THE

EQUIPMENT IS DRAWN TO SCALE, THE CONTRACTOR SHALL MAKE USE OF ALL

DATA IN ALL THE CONTRACT DOCUMENTS, TO ACCOMPLISH A COMPLETE,

OPERABLE AND MAINTAINABLE INSTALLATION.

15. ALL INSULATION AND COVERINGS INSTALLED ON PIPING AND TUBING SHALL

HAVE A FLAME-SPREAD RATING NOT TO EXCEED 25 AND A SMOKE DENSITY

NOT TO EXCEED 50 WHEN TESTED IN ACCORDANCE WITH NFPA 255. (PER

PARAGRAPH 1201.2.1.8 CMC 2022.

16. CONTRACTOR SHALL MEET OWNER'S CONSTRUCTION STANDARDS.

17. THE SYSTEM SHALL REMAIN OPERATIONAL EXCEPT FOR SCHEDULED

SHUT-DOWNS.

18. CONTRACTOR SHALL VERIFY LOCATION OF UTILITIES AND SCHEDULE WITH

FACILITY ENGINEER "OFF-HOURS" GENERAL SYSTEM SHUT-DOWN OF THE

UTILITIES.

19. ALL NEW PIPE AND EQUIPMENT SUPPORTS AND SEISMIC SHALL COMPLY WITH

OSHPD REQUIREMENTS AND ASCE/SEI 7.

20. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE A FULLY FUNCTIONAL

INSTALLATION AND TO INTEGRATE THE NEW WORK TO EXISTING SITE

CONDITIONS.

21. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS OF PIPING, CONTROLS AND

PIPING SYSTEMS TO OWNER REPESENTATIVE FOR APPROVAL PRIOR TO

FABRICATION. CONTRACTOR SHALL PROVIDE EQUIPMENT SUBMITTALS OF ALL

HARDWARE TO BE INSTALLED ON THIS JOB PRIOR TO PURCHASE.

22. CONTRACTOR SHALL LABEL FINAL PIPING INSTALLATION SHOWING DIRECTION

OF FLOW ARROWS AND TYPE OF WATER (E.G. CONDENSER WATER SUPPLY,

AND RETURN, VENT, DRAIN, ETC).

23. CONTRACTOR SHALL PROVIDE ONE (1) HARD COPY AND ONE (1) SOFT COPY OF

EQUIPMENT SUBMITTALS OR SHOP DRAWINGS OF ALL EQUIPMENT SPECIFIED

IN THE MATERIAL LIST AND SCHEDULES ON DRAWINGS M0.2, TO OWNER

REPRESENTATIVE FOR APPROVAL PRIOR TO PURCHASE.

24. CONTRACTOR SHALL PROVIDE ONE (1) HARD COPY AND ONE (1) SOFT COPY OF

OPERATION & MAINTENANCE MANUALS OF ALL EQUIPMENT SPECIFIED.

25. CONTRACTOR SHALL INSTALL NEW PIPING WITH SPOOL SECTIONS TO ALLOW

MAINTENANCE ACCESS TO NEW EQUIPMENT PER EQUIPMENT

MANUFACTURER'S REQUIREMENT AND ALL CODE CLEARANCES.

MECHANICAL PIPING LEGEND

SYMBOL DESCRIPTION

FUEL SYSTEM NOTES

1. REFER TO SPECIFICATIONS AND SHEETS M0.1, M2.1, and M3.1 FOR FUEL

SYSTEM REQUIREMENTS.

2. CONTRACTOR SHALL USE A SINGLE SUPPLIER AND SHALL PROVIDE ALL

COMPONENTS OF FUEL SYSTEM FOR A COMPLETE WORKING SYSTEM.

3. COORDINATE WITH ELECTRICAL SHEETS FOR ELECTRICAL REQUIREMENTS.

4. CONTRACTOR SHALL PAINT ALL NEW FUEL PIPING PER SPECIFICATIONS.

MECHANICAL GENERAL NOTES

1. ALL WELDING ON PROJECT SHALL BE PER ASME B31.1 STANDARDS.

2. CONTRACTOR SHALL PROVIDE PIPING LABELS WHICH SHOW DIRECTION OF

FLOW AND TYPE OF SERVICE. ALL NEW LINES SHALL BE LABELED PER

SPECIFICATIONS.

3. ALL UTILITIES SHUTDOWNS SHALL BE REQUESTED 72 HOURS IN ADVANCE FOR

APPROVAL.

4. ALL JOB SITE WORK HOURS SHALL BE COORDINATED WITH THE INSTITUTION.

5. ALL EQUIPMENT CONNECTIONS SHALL NOT HAVE A DIAMETER LESS THAN

THAT OF THE INLET CONNECTIONS TO THE EQUIPMENT AS PROVIDED BY THE

MANUFACTURER AND EACH EQUIPMENT SHALL BE CONNECTED TO THE PIPING

WITH MATERIALS AS APPROVED IN 2022 CPC.

ADDITIVEADD

ENHANCED VAPOR RECOVERYEVR

DEMOLITION WORK

EXISTING

NEW WORK

DEMOLITION/ DEMOLISHDEMO

HOSE

V2

OFFICE OF THE STATE FIRE MARSHAL

shall be available on the project site at all times.

03/04/25

APPROVED FIRE AND PANIC ONLY

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans

M1.1

MECHANICAL DEMOLITION

PLAN

Checked

Vault File Number

Project Number

Reference North Sheet Scale

Sheet Number

Designed

Sheet Title

Supervisor

Issue Date

Drawn

Project

Description

No.

Date Issue

JCCA #: 24791-8

00000000000XXXX

DEPARTMENT OF STATE

HOSPITALS - ATASCADERO

DEPARTMENT OF

STATE HOSPITALS

(DSH)

AS SHOWN

DSA STAMP

FUEL SERVICE

EQUIPMENT

REPLACEMENT

DSH

10/25/2024

100% SUBMITTAL

Client Agency

DEPARTMENT OF STATE HOSPITALS

385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501

P: 310.212.7644 F:310.212.5272I

BUILDING KEYPLAN

N

JCCA

D A T E T

IM

E F e b ru a ry

:2

P

M

F

IL

E L \2

-8

F u e l S e rv ic e E q u ip m e n t R e p la c e m e n t, D

S H

-A \C

A D

\2 M

DEMOLITION KEYNOTES:

(D) - DEMO AND REPLACE

(E) - EXISTING TO REMAIN, PROTECT IN PLACE

(D) FUEL DISPENSING UNIT. INCLUDING DISPENSING NOZZLE.

(E) FUEL TANK MOUNTING BRACKET.

(E) FUEL FILL PIPING.

(E) FILL POUR SYSTEM AND ASSOCIATED PIPING.

(D) FUEL OIL PIPING TO FUEL OIL TANK. (E) FUEL OIL TANK AND

FUEL OIL TANK WELDED PLUMBING COUPLING.

(D) FUEL SENSING LINE.

(D) FUEL OIL LEVEL SENSOR.

1"

1" 2"

(E) FIRE

EXTINGUISHER

AREA OF

WORK

1"

(E) FUEL FILL VAPOR

RECOVERY STATION

(E) EMERGENCY

VENT

(E) VENT

(E) 4000 GAL.

FUEL TANK

MECHANICAL DEMOLITION PLAN

SCALE: N0 41 FEET3

1/2" = 1'-0"

(E) CHAIN LINK

FENCE

(E) PEDESTRIAN

GATE

(E) PEDESTRIAN

GATE

V2

OFFICE OF THE STATE FIRE MARSHAL

shall be available on the project site at all times.

03/04/25

APPROVED FIRE AND PANIC ONLY

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans

M0.2

MECHANICAL SCHEDULES

Checked

Vault File Number

Project Number

Reference North Sheet Scale

Sheet Number

Designed

Sheet Title

Supervisor

Issue Date

Drawn

Project

Description

No.

Date Issue

JCCA #: 24791-8

00000000000XXXX

DEPARTMENT OF STATE

HOSPITALS - ATASCADERO

DEPARTMENT OF

STATE HOSPITALS

(DSH)

AS SHOWN

DSA STAMP

FUEL SERVICE

EQUIPMENT

REPLACEMENT

DSH

10/25/2024

100% SUBMITTAL

Client Agency

DEPARTMENT OF STATE HOSPITALS

385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501

P: 310.212.7644 F:310.212.5272I

JCCA

D A T E T

IM

E F e b ru a ry

:2

P

M

F

IL

E L \2

-8

F u e l S e rv ic e E q u ip m e n t R e p la c e m e n t, D

S H

-A \C

A D

\2 M

ITEM DESCRIPTION SPECIFICATION

EQUIPMENT SCHEDULE

FUEL MASTER LIVE PEDESTAL. AIRCRAFT QUALITY ALUMINUM. PROVIDE TMU EXPANSION CARD WITHIN UNIT. INCLUDE PROKEE READER

TO AUTHORIZE FUELING TRANSACTIONS BY USERS.

OMNTEC TANK GAUGING AND LEAK DETECTION SYSTEM, MODEL OEL8000IIIK OR APPROVED EQUAL. ACCEPTS UP TO 8

MAGNEOSTRICTIVE PROBES, UP TO 16 BRIGHT EYE SENSORS, COLOR 7-INCH GRAPHIC DISPLAY WITH CAPACITIVE TOUCH SCREEN.

BUILT IN WEB SERVER AND VPN CAPABILITY. ETHERNET / TCP / IP STANDARD WITH UP TO 5 BUILT IN PROGRAMMABLE RELAYS. 120VAC, 14LBS, 10" x 15.2" x 5.1" (H x W x D).

DRESSER WAYNE DIGITAL COMPACT DISPENSER, MODEL S1 COMPACT DISPENSER OR APPROVED EQUAL. POWDER-COATED METALLIC SILVER SIDES, TOP AND BASE. DOORS POWDER-COATED BLUE WITH CHARCOAL GRAY BEZEL WITH MATCHING DECAL WITH WHITE

LETTERING. EXTERIOR PANELS FABRICATED FROM HEAVY GAUGE GALVANNEALED STEEL WITH REMOVABLE DOORS. LIFT-TO-START ACTIVATION NOZZLE BOOT. SHELF-MOUNTED. WORKING PRESSURE UP TO 50 PSI, 30-1/4" x 22-5/8" x 18-1/8" (H x W x D). MOUNTING

PROVISIONS

FUEL OIL

DISPENSER

FUEL

MONITORING

SYSTEM

FUEL MASTER

LIVE PEDESTAL

FILL-RITE FUEL TRANSFER PUMP, MODEL FR700VN OR APPROVED EQUAL. HEAVY DUTY CAST IRON BODY, 20 GAL/MIN. 115V AC, 2" BUNG

INLET. THERMALLY PROTECTED, MESH STRAINER FILTER. 1/3 HP. 3/4" OUTLET

FUEL OIL

TRANSFER PUMP

OMNTECH BRIGHT EYE SENSOR, MODEL BX-LS OR APPROVED EQUAL. SHIELDED 22 AWG WITH DRAIN WIRE, MAXIMUM LENGTH 2,000

FEET. MOUNTING INTERFACE.

LEVEL SENSOR

OMNTECH REMOTE ANNUNCIATOR, MODEL RAS-1-NYS OR APPROVED EQUAL. LED INDICATORS RATED MTBF 11 YEARS. HIGH DECIBEL, HIGH INTENSITY AUDIBLE ALARM WITH VISUAL INDICATOR OF FLASHING STROBE BEACON. NEMA-4X RATING.OVERFILL ALARM

OMNTECH MAGNETOSTRICTIVE TANK GAUGING PROBE IN TANK LEAK DETECTION, MODEL MTG-RS-R5F1 OR APPROVED EQUAL.TANK PROBE

REMARKS

NOTES:

PROVIDE PROKEE ENCODER, CONNECTS TO COMPUTER TO ALLOW CODING OF KEYCARDS. PROKEE READER ACCEPTS PROKEE CARDS.

PROVIDE TMU INTERFACE WITHIN UNIT.

PROVIDE OMNTEC FIBERGLASS HINGE COVER, MODEL ENC-4X / ENC-4X-NW OR APPROVED EQUAL.

CONNECT TO FUEL MONITOR SYSTEM.

EQUIPMENT WETTED COMPONENTS TO BE COMPATIBLE WITH E-10 FUEL.

PIPE MATERIAL SCHEDULE

SERVICE/

PIPING

LOCATION

MATERIAL

OUTSIDE

BLACK STEEL,

TYPE E OR S

SCH 40, GRADE B

STAINLESS STEEL

TYPE 304

STAINLESS STEEL

TYPE 316

DRAWN TEMPER

COPPER

ANNEALED TEMPER

COPPER

FLEXIBLE,

NONMETALLIC,

REMARKS

OUTSIDE

OUTSIDEHOSE

FOR

FOS

FMU

FMS

FOD

FTP

LS

OA

TP

V2

OFFICE OF THE STATE FIRE MARSHAL

shall be available on the project site at all times.

03/04/25

APPROVED FIRE AND PANIC ONLY

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans

M2.1

MECHANICAL NEW WORK

PLAN

Checked

Vault File Number

Project Number

Reference North Sheet Scale

Sheet Number

Designed

Sheet Title

Supervisor

Issue Date

Drawn

Project

Description

No.

Date Issue

JCCA #: 24791-8

00000000000XXXX

DEPARTMENT OF STATE

HOSPITALS - ATASCADERO

DEPARTMENT OF

STATE HOSPITALS

(DSH)

AS SHOWN

DSA STAMP

FUEL SERVICE

EQUIPMENT

REPLACEMENT

DSH

10/25/2024

100% SUBMITTAL

Client Agency

DEPARTMENT OF STATE HOSPITALS

385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501

P: 310.212.7644 F:310.212.5272I

BUILDING KEYPLAN

N

JCCA

D A T E T

IM

E F e b ru a ry

:2

P

M

F

IL

E L \2

-8

F u e l S e rv ic e E q u ip m e n t R e p la c e m e n t, D

S H

-A \C

A D

\2 M

NEW WORK KEYNOTES:

(N) - PROVIDE AND INSTALL,

(N) FUEL OIL DISPENSER. INSTALL ON (E) FUEL OIL TANK SIDE

BRACKET. ABIDE BY MANUFACTURER'S MOUNTING

REQUIREMENTS.

(N) VST EVR NOZZLE. PROVIDE WITH NEW HANGING HARDWARE.

(N) TANK MOUNTED FUELOIL TRANSFER PUMP.

(N) LEVEL SENSOR.

(N) TANK GAUGING PROBE FOR LEAK DETECTION. (N) EVR CAP.

(N) OMNTECH TANK GAUGING AND LEAK DETECTION MONITOR.

(N) TAMPERPROOF COVER.

(N) FUEL MASTER LIVE PEDESTAL WITH PROKEE READER AND

TMU INTERFACE. INSTALL PER MANUFACTURER REQUIREMENTS.

ABIDE BY EQUIPMENT CLEARANCE REQUIREMENTS. MAINTAIN

AT LEAST 18" OF CLEARANCE TO ANY SURROUNDING

EQUIPMENT.

(N) REMOTE ANNUNCIATOR.

(N) SPLITTER VALVE TO CONNECT VAPOR RETURN TO TANK AND

FUEL DISPENSING HOSE. MODEL: EMCO WHEATON A4041

SPLITTER OR APPROVED EQUAL.

FUEL SYSTEM NOTES:

1. CONTRACTOR SHALL INSTALL ALL PIPING, FUEL SERVICE

EQUIPMENT, ALL ELECTRICAL WIRING AND CONTROLS WIRING,

FOR A COMPLETE WORKING SYSTEM AND SHALL CONNECT TO

EXISTING WIRING FOR MAIN TANK.

2. EXISTING ABOVE GROUND STORAGE TANKS SHALL BE PER

NFPA 30 (NATIONAL FIRE PROTECTION ASSOCIATION). TANK

SHALL HAVE DOUBLE WALL CONTAINMENT AND SHALL BE

BUILT PER UL142 WITH UL508 COMPLIANT DAY TANK

CONTROLS AND REQUIREMENTS PER 2022 IFC

(INTERNATIONAL FIRE CODE).

3. SIGNAGE AND MARKINGS SHALL BE INSTALLED PER NFPA 704.

4. FUEL SYSTEM AND TANKS SHALL BE CONNECTED TO MASTER

CONTROLLER.

5. CONTRACTOR SHALL ROUTE PIPING TO AND FROM FUEL

SERVICE EQUIPMENT PER MANUFACTURER'S REQUIREMENTS.

6. PIPING SHALL BE PRESSURE TESTED PRIOR TO START UP.

7. FINAL INSTALLATION OF FUEL PIPING AND FUEL SERVICE

PIPING SHALL BE IN ACCORDANCE WITH AN APPROVED PIPING

FLOW DIAGRAM AND CONNECTION DETAILS PROVIDED BY

CONTRACTOR'S FUEL DESIGNER AND APPROVED BY

MECHANICAL ENGINEER OF RECORD (MEOR).

1-1/4" FOS

1" FOR

1"

F R

O N

T

(E) EMERGENCY

VENT

(E) VENT

(E) 4,000 GAL.

FUEL TANK

FMU

FMS

FOD

FTP

LS

OA 1

TP

MECHANICAL NEW WORK PLAN

SCALE: N0 41 FEET3

1/2" = 1'-0"

AREA OF

WORK

(E) FUEL FILL

VAPOR RECOVERY

STATION

(E) CHAIN LINK

FENCE

(E) PEDESTRIAN

GATE

(E) PEDESTRIAN

GATE

V2

OFFICE OF THE STATE FIRE MARSHAL

shall be available on the project site at all times.

03/04/25

APPROVED FIRE AND PANIC ONLY

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans

M3.1

MECHANICAL DETAILS

Checked

Vault File Number

Project Number

Reference North Sheet Scale

Sheet Number

Designed

Sheet Title

Supervisor

Issue Date

Drawn

Project

Description

No.

Date Issue

JCCA #: 24791-8

00000000000XXXX

DEPARTMENT OF STATE

HOSPITALS - ATASCADERO

DEPARTMENT OF

STATE HOSPITALS

(DSH)

AS SHOWN

DSA STAMP

FUEL SERVICE

EQUIPMENT

REPLACEMENT

DSH

10/25/2024

100% SUBMITTAL

Client Agency

DEPARTMENT OF STATE HOSPITALS

385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501

P: 310.212.7644 F:310.212.5272I

JCCA

D A T E T

IM

E F e b ru a ry

:2

P

M

F

IL

E L \2

-8

F u e l S e rv ic e E q u ip m e n t R e p la c e m e n t, D

S H

-A \C

A D

\2 M

VEHICLE FUELING TANK DETAIL

NO SCALEM3.1

COMPONENT DESCRIPTION:

FUEL MASTER LIVE PEDESTAL.

FUEL TRANSFER PUMP.

FUEL OIL DRESSER WAYNE DISPENSER.

OMNTECH LEAK SENSOR.

OMNTECH MAGNETOSTRICTIVE TANK GAUGING PROBE.

FUEL OIL RETURN. 1" DIA PIPE.

FUEL OIL SUPPLY. 1-1/4" DIA PIPE.

FUEL OIL RETURN. 1" DIA PIPE.

FUEL OIL HOSE.

(E) - EMERGENCY VENT.

(E) - FILL & VAPOR PIPING.

(E) - VENT.

(E) - ABOVEGROUND FUEL STORAGE TANK.

(E) - CONCRETE PAD.

LANE-ORIENTED NOZZLE BOOT.

TO FILL SYSTEM

V2

OFFICE OF THE STATE FIRE MARSHAL

shall be available on the project site at all times.

03/04/25

APPROVED FIRE AND PANIC ONLY

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans

-DRDR

E0.1

ELECTRICAL COVER SHEET

Checked

Vault File Number

Project Number

Reference North Sheet Scale

Sheet Number

Designed

Sheet Title

Supervisor

Issue Date

Drawn

Project

Description

No.

Date Issue

JCCA #: 24791-8

00000000000XXXX

DEPARTMENT OF STATE

HOSPITALS - ATASCADERO

DEPARTMENT OF

STATE HOSPITALS

(DSH)

AS SHOWN

DSA STAMP

FUEL SERVICE

EQUIPMENT

REPLACEMENT

DSH

10/25/2024

100% SUBMITTAL

Client Agency

DEPARTMENT OF STATE HOSPITALS

385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501

P: 310.212.7644 F:310.212.5272I

JCCA

D A T E T

IM

E N o v e m b e r :0

P

M

F

IL

E L \2

-8

F u e l S e rv ic e E q u ip m e n t R e p la c e m e n t, D

S H

-A \C

A D

\2 E

LIGHT, THIN LINES INDICATE EXISTING.

HEAVY, THICK LINES INDICATE NEW

HEAVY, SHORT DASHED LINES INDICATE

DEMOLITION OR REMOVAL

TYPICAL PLAN LEGEND

THIS SYMBOLOGY TO BE USED BY ELECTRICAL AND LAYOUT FOR ALL

FLOOR PLANS, EQUIPMENT, DEVICES, UTILITIES, ETC., SHOWN ON

DRAWINGS.

ABBREVIATIONS ELECTRICAL SYMBOL LIST

SWITCHBOARD 240D/120V, 3Ø, 4W

PANELBOARD 240D/120V, 3Ø, 4W

P4-10 BRANCH CIRCUIT DESTINATION (PANEL NAME-CIRCUIT

NUMBER)

HOMERUN INDICATES PROVIDING CONDUIT AND

CONDUCTORS

MINIMUM CONDUIT SIZE: 3/4"

MINIMUM CONDUCTOR SIZE: #12AWG

PROVIDE 3/4"C-2#12+1#12G WHERE NO CONDUIT/WIRE SIZE IS

STATED.

PROVIDE DEDICATED NEUTRAL FOR ALL BRANCH CIRCUIT

WIRING.

CONTRACTOR RESPONSIBLE FOR DE-RATING CONDUIT WITH

MORE THAN SIX CURRENT CARRYING CONDUCTORS PER CEC

310.

#12 AWG FOR CIRCUITS UP TO 100'

#10 AWG FOR CIRCUITS FROM 100' TO 200'

#8 AWG FOR CIRCUIT GREATER THAN 200'

UNFUSED DISCONNECT SIZED AS INDICATED ON DWGS.

CONTRACTOR TO CONFIRM FUSE SIZING BASED ON

EQUIPMENT MANUFACTURER RECOMMENDAITON

JUNCTION BOX

1. ALL WORK MUST BE PERFORMED IN COMPLIANCE WITH APPLICABLE CODES

AND STANDARDS. SEE T0.1 FOR A LIST OF APPLICABLE CODES AND

STANDARDS.

2. CEC 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED,

OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY

ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH

ADMINISTRATION.

3. CEC 130.5(C): VOLTAGE DROP: THE MAXIMUM COMBINED VOLTAGE DROP ON

BOTH INSTALLED FEEDER CONDUCTORS AND BRANCH CIRCUIT CONDUCTORS

TO THE FARTHER CONNECTED LOAD OR OUTLET SHALL NOT EXCEED 5

PERCENT.

4. ALL CABLE/WIRE, CONDUIT RUNS ARE SHOWN DIAGRAMMATICALLY & THEY

SHALL BE ROUTED TO SUIT ACTUAL FIELD CONDITIONS, EXCEPT WHERE

LOCATIONS ARE EXPLICITLY DIMENSIONED ON THE DRAWINGS.

5. THE ELECTRICAL CONSTRUCTION DRAWINGS PROVIDED HEREIN ARE

DIAGRAMMATIC AND SYMBOLIC IN REPRESENTATION. LOCATIONS DEPICTED

ON THE DRAWINGS FOR ELECTRICAL EQUIPMENT/DEVICES (MOTORS,

STARTERS, DISCONNECT SWITCHES, RECEPTACLES, JUNCTION/OUTLET BOXES,

CONTROL SWITCHES, EQUIPMENT RACKS, SMALL TRANSFORMERS, ETC.) ARE

ONLY APPROXIMATE. FURTHERMORE, THE EQUIPMENT/DEVICE DEPICTIONS

ARE GENERALLY SYMBOLIC AND NOT DRAWN TO SCALE.

6. IN EVENT OF CONFLICT OR DISCREPANCY BETWEEN DRAWINGS,

SPECIFICATIONS, CONTRACT DOCUMENTS, SPECIFICATIONS, DRAWINGS AND

SITE CONDITIONS, THE CONTRACTOR SHALL PROVIDE THE MORE STRINGENT

OF THE DRAWINGS, SPECIFICATIONS, AND CONTRACT DOCUMENTS FOR THE

CONSTRUCTIONS AND BIDDING PURPOSES.

7. ELECTRICAL DRAWINGS INDICATE NEW WORK, UNLESS OTHERWISE NOTED.

EXISTING ELECTRICAL SYSTEMS ARE NOT SHOWN EXCEPT WHERE

INTERFACING IS REQUIRED.

8. ALL NEW BOXES, PANELS, OUTLET COVERS, ENCLOSURES, ETC. MOUNTED ON

THE EXTERIOR OF ANY STRUCTURE SHALL BE WEATHERPROOF (NEMA 3R

MINIMUM) & ALSO PAINTED TO MATCH THE EXISTING BUILDING/STRUCTURE.

9. ALL EXISTING SURFACES DAMAGED BY NEW CONSTRUCTION, SHALL BE

PATCHED, OR REPAINTED TO MATCH EXISTING CONDITIONS, PAINTED

SURFACE SHALL BE PAINTED FROM BREAK TO BREAK. IT SHALL BE THE

CONTRACTORS RESPONSIBILITY TO PATCH & REPAIR ALL DAMAGE TO EXISTING

SURFACES AND FINISHES. FURTHERMORE, THE AFFECTED AREA(S) OF WORK

SHALL BE REPAIRED TO MATCH THE FINISH THAT WAS PREVIOUSLY EXISTING,

PRIOR TO THE COMMENCEMENT OF WORK.

10. RUN CONDUITS CONCEALED IN WALLS AND CEILINGS UNLESS NOTED. CUT

EXISTING WALLS AS REQUIRED. PATCH AND PAINT TO MATCH EXISTING

SURFACE.

11. UPDATE ALL POWER PANEL DIRECTORIES AND ELECTRICAL OUTLET

IDENTIFICATION LABELS (KROYTAPE) TO REFLECT NEW CONSTRUCTION.

12. ALL FLEX AND SEALTIGHT CONDUIT SHALL HAVE A GROUND CONDUCTOR.

13. CONDUITS PENETRATING FIRE RATED AREAS SHALL BE SEALED, INSTALLED ON

OUTSIDE OF CONDUIT, WITH APPROVED FIRE STOP MATERIAL TO MAINTAIN THE

SAME FIRE RATING AS ORIGINAL.

14. ALL MATERIALS AND WORKS ARE NEW, UNLESS OTHERWISE NOTED. EXISTING

ELECTRICAL SYSTEMS ARE NOT SHOWN EXCEPT WHERE INTERFACING IS

REQUIRED.

15. MAINTAIN CONTINUITY OF ALL EXISTING CIRCUITS OR PORTIONS THEREOF

AFFECTED BY NEW WORK.

16. CONTRACTOR SHALL VISIT AND FAMILIARIZE AT THE SITE PRIOR TO START OF

PROJECT. COORDINATE WITH OWNER REPRESENTATIVE FOR EXACT LOCATION

OF ALL EQUIPMENT.

17. SEISMIC ANCHORAGE OF ALL NEW AND EXISTING PIPING, CONDUIT,

DUCTWORK, EQUIPMENT, PANELS, ETC. SHALL BE BY FOLLOWING THE

MANUFACTURERS SPECIFICATIONS IN ACCORDANCE WITH THE 2019 CBC AND

THE LATEST ISSUE OF "ENGINEERED SEISMIC BRACING OF SUSPENDED

UTILITIES" AS PUBLISHED BY THE INTERNATIONAL SEISMIC APPLICATION

TECHNOLOGY (ISAT) OPA-0485, MASON INDUSTRIES OPA-0349, TOLCO

OPA-0300, COOPER B-LINE OPA-0114, OR M.W. SAUSSE OPA-0029 OR EQUAL.

18. CONDUIT FITTINGS FOR USE IN EMT RUNS SHALL BE GALVANIZED STEEL

CONNECTORS AND COUPLINGS SHALL BE WATERTIGHT TYPE.

19. ALL SINGLE PHASE CIRCUITS SHALL HAVE A DEDICATED NEUTRAL.

20. ALL CONDUITS SHALL BE PROVIDED AN EQUIPMENT GROUNDING CONDUCTOR

SIZED PER CEC 250.

21. ALL NEW (ADDITIONAL) METALLIC STRUCTURES AND EQUIPMENT FABRICATED

WITH METALLIC MATERIALS SUCH AS GENERATORS, MOTOR FRAME,

ENCLOSURES, ETC, PANELS, RACEWAY SHALL BE PERMANENTLY &

EFFECTIVELY GROUNDED, WHETHER SHOWN ON DRAWING OR NOT. GROUND

CABLE SHALL BE CONNECTED TO COLD WATER PIPE PER CEC 250.52(A)(1), TO

BUILDING GROUNDING PER CEC 250.52(A)(2) OR CONNECTED TO GROUND ROD

PER CEC 250.52(A)(5).

22. OWNER RESERVES THE RIGHT TO REQUIRE MINOR CHANGES IN LOCATION OF

OUTLETS OR EQUIPMENT PRIOR TO ROUGHING-IN WITHOUT INCURRING ANY

ADDITIONAL COST OR CHARGES.

23. DURING CONSTRUCTION, DO NOT INTERRUPT OR IMPEDE OPERATION AND

WORK IN ADJACENT AREAS.

24. UPON COMPLETION OF ALL WORK, THOROUGHLY CLEAN ALL EQUIPMENT AND

DUCTS FROM INSIDE AND OUTSIDE OF EQUIPMENT. REMOVE ALL TRACES OF

SOIL, DUST, LABELS, GREASE, OIL, AND FOREIGN MATERIALS. CLEANUP AND

REMOVE FROM THE PREMISES ALL DEBRIS AND SURPLUS MATERIAL CAUSED

BY THIS WORK.

25. WHERE THERE IS A CONFLICT BETWEEN THE DRAWINGS & ANY RELEVANT

CODES, THE CODES SHALL GOVERN, EXCEPT WHERE THE DRAWINGS INDICATE

A QUALITY LEVEL SUPERIOR TO THAT SPECIFIED BY THE CODES.

26. THE WORD "PROVIDE" MEANS THAT THE CONTRACTOR SHALL FURNISH,

INSTALL, ADJUST, TEST, AND INTEGRATE INTO A COMPLETE SYSTEM THE ITEM

INDICATED INCLUDING ALL HARDWARE, WIRING AND MISCELLANEOUS ITEMS

AS NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM.

GENERAL NOTES

15A, 125V DUPLEX RECEPTACLE (NEMA 5-15R)

SUBSCRIPTS DENOTE THE FOLLOWING:

"WP" - WEATHERPROOFED

DISTANCE

DENOTES EXISTING

CIRCUIT BREAKER

EACH

COPPER

GROUND

MINIMUM

AMPERE

CIRCUIT

LOW VOLTAGE

AMPERE

INTERRUPTING

CAPACITY

ABOVE FINISHED

FLOOR

NOT TO SCALE

WEATHER PROOFWP

SWITCHBOARDSWBD

TYP. TYPICAL

UG UNDERGROUND

SWITCHSW

PULL BOXPB

SLD SINGLE LINE DIAGRAM

POLEP

PANELBOARDPNL

(R) RELOCATED

SUB SUBSTATION

NEW(N)

TIME DELAY

UNLESS

OTHERWISE

NOTED

UON

TRANSFORMERXFMR,

TRANSF.

VD VOLTAGE DROP

TD

DEMOLITION

D

(E)

CB

EA

CU

GND, G

MIN

A

CKT

LV

AIC

AFF

NTS

(D)

V2

OFFICE OF THE STATE FIRE MARSHAL

shall be available on the project site at all times.

03/04/25

APPROVED FIRE AND PANIC ONLY

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans

-DRDR

E0.2

ELECTRICAL PANEL

SCHEDULE A

Checked

Vault File Number

Project Number

Reference North Sheet Scale

Sheet Number

Designed

Sheet Title

Supervisor

Issue Date

Drawn

Project

Description

No.

Date Issue

JCCA #: 24791-8

00000000000XXXX

DEPARTMENT OF STATE

HOSPITALS - ATASCADERO

DEPARTMENT OF

STATE HOSPITALS

(DSH)

AS SHOWN

DSA STAMP

FUEL SERVICE

EQUIPMENT

REPLACEMENT

DSH

10/25/2024

100% SUBMITTAL

Client Agency

DEPARTMENT OF STATE HOSPITALS

385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501

P: 310.212.7644 F:310.212.5272I

JCCA

D A T E T

IM

E F e b ru a ry

:1

P

M

F

IL

E L \2

-8

F u e l S e rv ic e E q u ip m e n t R e p la c e m e n t, D

S H

-A \C

A D

\2 E

PANEL SCHEDULE A

NO SCALE

NEW WORK KEYNOTES:

PROVIDE 20A/1P CIRCUIT BREAKER, WITH KAIC TO MATCH

EXISTING (E.G. 10 KAIC).

DEMOLITION KEYNOTES:

DEMOLISH 40/3P CIRCUIT BREAKER PREVIOUSLY SERVING (D)

FUEL DISPENSER.

1 1

LOAD SUMMARY:

PANELBOARD A (208/120V, 3Ø, 4W):

LOAD REMOVED = 11.5 KVA

LOAD ADDED = 1.1 KVA

LOAD DELTA = -10.4 KVA

PER LOAD SUMMARY ABOVE, THE LOAD ON PANELBOARD A HAS

BEEN REDUCED. EXISTING PANELBOARD, INCLUDING

OVERCURRENT PROTECTION AND FEEDERS, IS ADEQUATE TO

SERVE THE CONNECTED LOAD.

V2

OFFICE OF THE STATE FIRE MARSHAL

shall be available on the project site at all times.

03/04/25

APPROVED FIRE AND PANIC ONLY

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans

E1.1

ELECTRICAL DEMOLITION

SITE PLAN

Checked

Vault File Number

Project Number

Reference North Sheet Scale

Sheet Number

Designed

Sheet Title

Supervisor

Issue Date

Drawn

Project

Description

No.

Date Issue

JCCA #: 24791-8

00000000000XXXX

DEPARTMENT OF STATE

HOSPITALS - ATASCADERO

DEPARTMENT OF

STATE HOSPITALS

(DSH)

AS SHOWN

DSA STAMP

FUEL SERVICE

EQUIPMENT

REPLACEMENT

DSH

10/25/2024

100% SUBMITTAL

Client Agency

DEPARTMENT OF STATE HOSPITALS

385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501

P: 310.212.7644 F:310.212.5272I

BUILDING KEYPLAN

N

JCCA

D A T E T

IM

E F e b ru a ry

:1

P

M

F

IL

E L \2

-8

F u e l S e rv ic e E q u ip m e n t R e p la c e m e n t, D

S H

-A \C

A D

\2 E

DEMOLITION KEYNOTES:

DEMOLISH POWER AND CONTROLS SERVING (D) MECHANICAL.

PREPARE TO REPLACE IN NEW WORK.

DEMOLISH LEVEL SENSOR AND ASSOCIATED WIRING. PREPARE

TO REPLACE IN NEW WORK.

DEMOLISH DISCONNECT SWITCH AND ASSOCIATED CONDUIT AND

CONDUCTORS. DEMOLISH ASSOCIATED 40A/3P CIRCUIT BREAKER

IN SPACES 19,21,23 OF PANEL A AS SHOWN ON PANEL SCHEDULE

ON E0.3 AND PREPARE TO REPLACE IN NEW WORK.

(E) UNDERGROUND CONDUIT TO

REMAIN

(E) CONDUIT ABOVE GROUND(E) PULLBOX

ELECTRICAL NEW WORK PLAN

SCALE: N0 41 FEET3

1/2" = 1'-0"

BUILDING 810 ABOVE / BUILDING 850 BELOW

(SEE E2.2 FOR FLOOR PLANS)

V2

OFFICE OF THE STATE FIRE MARSHAL

shall be available on the project site at all times.

03/04/25

APPROVED FIRE AND PANIC ONLY

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans

19' (WITHIN 30')

F R

O N

T

A-19,21

A-23

-DRDR

E2.1

ELECTRICAL NEW WORK

SITE PLAN

Checked

Vault File Number

Project Number

Reference North Sheet Scale

Sheet Number

Designed

Sheet Title

Supervisor

Issue Date

Drawn

Project

Description

No.

Date Issue

JCCA #: 24791-8

00000000000XXXX

DEPARTMENT OF STATE

HOSPITALS - ATASCADERO

DEPARTMENT OF

STATE HOSPITALS

(DSH)

AS SHOWN

DSA STAMP

FUEL SERVICE

EQUIPMENT

REPLACEMENT

DSH

10/25/2024

100% SUBMITTAL

Client Agency

DEPARTMENT OF STATE HOSPITALS

385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501

P: 310.212.7644 F:310.212.5272I

BUILDING KEYPLAN

N

JCCA

D A T E T

IM

E F e b ru a ry

:1

P

M

F

IL

E L \2

-8

F u e l S e rv ic e E q u ip m e n t R e p la c e m e n t, D

S H -A

\C A D

\2 E

NEW WORK KEYNOTES:

PROVIDE 3/4"C-2#12+1#12G TO (N) FUEL OIL DISPENSER "FOD".

PROVIDE VST EVR NOZZLE. POWER THROUGH "FOD".

PROVIDE TANK-MOUNTED FUEL OIL TRANSFER PUMP "FTP".

PROVIDE 3/4"C-2#12+1#12G BETWEEN "FTP" AND "FOD" IN

EXPLOSION-PROOF, SEALED RMC.

PROVIDE LEVEL SENSOR "LS".

PROVIDE TANK GAUGING PROBE "TP".

PROVIDE OMNTEC TANK GAUGING AND LEAK DETECTION

MONITOR "FMS" WITH WITH TAMPERPROOF COVER. PROVIDE

1"C-2#12 +1#12C IN WALL-MOUNTED EXPLOSION-PROOF, SEALED

RMC.

PROVIDE FUELMASTER LIVE PEDESTAL "FMU". PROVIDE 1"C-2#12

+ 1#12G IN UNDERGROUND EXPLOSION-PROOF, SEALED RMC.

PROVIDE REMOTE ANNUNCIATOR "OA". PROVIDE 1" CONTROL

CONDUIT BETWEEN "OA" AND "FMS" PER MANUFACTURER'S

INSTRUCTIONS.

PROVIDE 1"C CONTROL CONDUIT AND WIRING CONNECTING "FMS"

AND BOTH "LS" AND "TP" PER MANUFACTURER'S

RECOMMENDATIONS.

PROVIDE 1"C CONTROL CONDUIT AND WIRING CONNECTING "FMS"

AND "FMU" PER MANUFACTURER'S RECOMMENDATIONS.

PROVIDE 1"C CONTROL CONDUIT AND CAT6 CONNECTING "FMU"

AND "FOD" PER MANUFACTURER'S RECOMMENDATIONS.

PROVIDE 30A, 120V DISCONNECT SWITCH WITHIN 30' OF ALL FUEL

EQUIPMENT. LABEL DISCONNECT WITH BRANCH CIRCUITS

SERVING (N) "FOD" AND (N) "FMU" AND "FMS" (E.G. CIRCUITS A-19

AND A-21, RESPECTIVELY). SEE E2.2 FOR BUILDING 810 FLOOR

PLAN.

PROVIDE 125V, NEMA 5-15R CONVENIENCE RECEPTACLE WITH

WEATHERPROOF COVER.

(E) PULLBOX

(E) EXPLOSION PROOF

UNDERGROUND CONDUIT

TO REMAIN

(E) UNDERGROUND

CONDUIT FEEDING

CONEX TO REMAIN

ELECTRICAL NEW WORK SITE PLAN

SCALE: N0 41 FEET3

1/2" = 1'-0"

GENERAL NOTES:

1. WORK SHALL COMPLY WITH CLASS 1, DIVISION 2

REQUIREMENTS PER CEC, ESPECIALLY CHAPTERS 501 AND 514.

2. CONDUIT SHALL BE EXPLOSION-PROOF RMC AND SEALED

WITHIN 10' OF DIVISION 2 BOUNDARY AND ANY STUB-UP

LOCATION. FILL PERCENTAGE SHALL NOT EXCEED 25% WITHIN

SEALED PORTION OF CONDUIT. TERMINATIONS SHALL BE

SEALED AT THE POINT OF ENTRANCE PER DETAIL 1/E3.1.

3. WHERE LIQUID OR OTHER CONDENSED VAPOR MAY BE

TRAPPED WITHIN ENCLOSURES, AN APPROVED MEANS SHALL

BE PROVIDED TO PREVENT ACCUMULATION OR PERMIT

PERIODIC DRAINING.

4. COORDINATE WORK WITH MECHANICAL.

5. PROVIDE CONTROL WIRING PER MANUFACTURER'S

RECOMMENDATIONS.

6. PROVIDE TRENCHES PER DETAILS 2/E3.1 AND 3/E3.1 FOR SOIL

AND CONCRETE, RESPECTIVELY.

LS

TP

FMU

FOD

FMS

8OA

10 11

3FTP

(E) EMERGENCY

VENT

(E) VENT

(E) 4000 GAL.

FUEL TANK

BUILDING 810 ABOVE / BUILDING 850 BELOW

(E) ROLL-UP DOOR

(SEE E2.2 FOR FLOOR PLANS)

WP

V2

OFFICE OF THE STATE FIRE MARSHAL

shall be available on the project site at all times.

03/04/25

APPROVED FIRE AND PANIC ONLY

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans

P A

IN

T S

TO

R A G

E

(E) PNL B

STORAGE

(ABOVE BLDG 850,

SAND BLAST AREA)

STORAGE

PAINT SPRAY

BOOTH

PAINT PARLOR

STORAGE

CURING OVEN

PAINT SHOP

(E) PNL A

SAND BLAST AREA

(LOWER LEVEL,

BELOW BLDG 810,

STORAGE 21)

NEW WORK KEYNOTES:

PROVIDE 3/4"C-6#12 + 3#12G.

PROVIDE TWO (2) 20A, 1P CIRCUIT BREAKERS IN PANEL A PER PANEL

SCHEDULE ON E0.2.

PROVIDE ONE (1) 15A, 1P CIRCUIT BREAKER IN PANEL A PER PANEL

SCHEDULE ON E0.2.

PROVIDE CONCRETE FIRESTOP FOR CONDUIT PENETRATION AT

CONCRETE DECK ABOVE PER DETAIL 4/E3.1. LABEL FIRE RATED

PENETRATION PER SPECIFICATIONS.

PROVIDE CONCRETE FIRESTOP AND SLEEVE CP 653, OR APPROVED

EQUAL, FOR CONDUIT PENETRATION AT CMU WALL PER DETAIL 5/E3.1.

LABEL FIRE RATED PENETRATION PER SPECIFICATIONS.

PROVIDE 30A, 120V DISCONNECT SWITCH.

BUILDING 810 ELECTRICAL NEW WORK FLOOR PLAN

SCALE: 0 81 FEET4

1/4" = 1'-0"

GENERAL NOTES:

1. FIRESTOP PENETRATIONS PER DETAILS 4/E3.1 AND

5/E3.1 FOR MINIMUM 2-1/2" AND 4-1/2" CONCRETE

CONDUIT PENETRATIONS RESPECTIVELY.

Checked

Vault File Number

Project Number

Reference North Sheet Scale

Sheet Number

Designed

Sheet Title

Supervisor

Issue Date

Drawn

Project

Description

No.

Date Issue

JCCA #: 24791-8

00000000000XXXX

DEPARTMENT OF STATE

HOSPITALS - ATASCADERO

DEPARTMENT OF

STATE HOSPITALS

(DSH)

AS SHOWN

DSA STAMP

FUEL SERVICE

EQUIPMENT

REPLACEMENT

DSH

10/25/2024

100% SUBMITTAL

Client Agency

DEPARTMENT OF STATE HOSPITALS

385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501

P: 310.212.7644 F:310.212.5272I

BUILDING KEYPLAN

N

JCCA

D A T E T

IM

E F e b ru a ry

:1

P

M

F

IL

E L \2

-8

F u e l S e rv ic e E q u ip m e n t R e p la c e m e n t, D

S H

-A \C

A D

\2 E

N

BUILDING 850 ELECTRICAL NEW WORK FLOOR PLAN

SCALE: 0 81 FEET4

1/4" = 1'-0"

N

(E) PULLBOX

OA

FMS

ROUTE CONDUIT TO

BUILDING 810 ABOVE

(E) ROLL-UP DOOR(E) DISCONNECT

PENETRATION FROM

BUILDING 850 BELOW

-DRDR

E2.2

BUILDING 810 AND 850

ELECTRICAL POWER NEW

WORK FLOOR PLANS

BLDG 810

BLDG

BLDG 810

FDN

KEY ELEVATION

NOT TO SCALE

6 (N) DISCONNECT

V2

OFFICE OF THE STATE FIRE MARSHAL

shall be available on the project site at all times.

03/04/25

APPROVED FIRE AND PANIC ONLY

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans

E3.1

ELECTRICAL DETAILS

Checked

Vault File Number

Project Number

Reference North Sheet Scale

Sheet Number

Designed

Sheet Title

Supervisor

Issue Date

Drawn

Project

Description

No.

Date Issue

JCCA #: 24791-8

00000000000XXXX

DEPARTMENT OF STATE

HOSPITALS - ATASCADERO

DEPARTMENT OF

STATE HOSPITALS

(DSH)

AS SHOWN

DSA STAMP

FUEL SERVICE

EQUIPMENT

REPLACEMENT

DSH

10/25/2024

100% SUBMITTAL

Client Agency

DEPARTMENT OF STATE HOSPITALS

385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501

P: 310.212.7644 F:310.212.5272I

JCCA

D A T E T

IM

E F e b ru a ry

:2

P

M

F

IL

E L \2

-8

F u e l S e rv ic e E q u ip m e n t R e p la c e m e n t, D

S H

-A \C

A D

\2 E

CONDUIT SEAL FITTINGS DETAIL

NO SCALEE3.1

FILL THICKNESS EQUAL TO CONDUIT

DIAMETER NOT LESS THAN 5/8"

FIBER FILLER

EYS VERTICAL

SEALING COMPOUND

CONDUIT

WYE

SEAL

VERTICAL CONDUIT SEAL

SEALING COMPOUND

FIBER FILLER

SEALING COMPOUND

FIBER FILLER

HORIZONTAL CONDUIT SEAL

WARNING TAPE

M

IN

ADDITIONAL OR LESS CONDUIT REQUIRE SAME SPACING

NOTE:

BACKFILL MATERIAL

SHALL BE 90%

COMPACTION

M

IN

RMC (TYP.)

CONCRETE ASPHALT

OR LANDSCAPE

CONDUITS IN SOIL DETAIL

NO SCALE E3.1

NOTES:

12" MIN SEPARATION BETWEEN DUCT BANK AND ALL OTHER UNDERGROUND

UTILITIES.

PROVIDE TEMPORARY CONDUIT SUPPORTS EVERY 4' FOR CONCRETE

POUR.

"M

IN

"M

IN

"M

IN

3"MIN. 2"MIN. 3"MIN.

REFILL WITH

NATIVE SOIL

COMPACTED

TO 90%

RMC (TYP.)

CAUTION TAPE

12" ABOVE CONCRETE

CAST IN PLACE

CONCRETE

ENCASEMENT (3000

PSI)

PAVE TO MATCH EXISTING CONDITIONS,

INCLUDING BUT NOT LIMITED TO, AC PAVING,

CONCRETE PAVING, CURBS, GUTTERS,

DRIVEWAYS, ETC. PER CIVIL DETAILS.

2 TYP.

System No. C-AJ-1575

SECTION A-A

1. FLOOR OR WALL ASSEMBLY — MIN 2-1/2 IN. (64 MM) THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR 1600-2400 KG/M3) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL

CLASSIFIED CONCRETE BLOCKS*. FLOOR MAY ALSO BE CONSTRUCTED OF ANY MIN 6 IN. (152 MM) THICK UL CLASSIFIED HOLLOW CORE PRECAST CONCRETE UNITS*. MAX DIAM OF OPENING IS 30-7/8 IN. (784 MM) WHEN CONCRETE FLOOR OR WALL IS USED AND MAX 7 IN. (178 MM) WHEN PRECAST CONCRETE UNITS ARE USED.

SEE CONCRETE BLOCKS (CAZT) AND PRECAST CONCRETE UNITS (CFTV) CATEGORIES IN THE FIRE

RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS.

1A. FLOOR ASSEMBLY - (OPTIONAL - NOT SHOWN) — THE FIRE RATED UNPROTECTED CONCRETE AND

STEEL FLOOR ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL D900 SERIES DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND AS SUMMARIZED

BELOW:

A. CONCRETE — MIN 2-1/2 IN. (114 MM) THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT

(100-150 PCF OR 1600-2400 KG/M3) CONCRETE.

B. STEEL FLOOR AND FORM UNITS* — COMPOSITE OR NON-COMPOSITE MAX 3 IN. (76 MM) DEEP

GALV STEEL FLUTED UNITS AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN.

2. STEEL SLEEVE — SEE TABLE IN ITEM 4B FOR WHEN SLEEVE IS REQUIRED. ALSO NOT REQUIRED FOR HOLLOW CORE PRECAST CONCRETE FLOORS. SCHEDULE 10 (OR HEAVIER) STEEL SLEEVE CAST OR GROUTED INTO FLOOR OR WALL ASSEMBLY. SLEEVE MAY EXTEND A MAX OF 8 IN. (203 MM) ABOVE TOP OF FLOOR OR BEYOND EITHER SURFACE OF WALL. AS AN ALTERNATE, IN FLOORS ONLY, MIN 26 GAUGE

GALVANIZED SHEET STEEL SLEEVE PROVIDED WITH A MIN. 26 GAUGE GALVANIZED STEEL SQUARE FLANGE SPOT WELDED TO THE BOTTOM OF THE SLEEVE AND SIZED TO BE A MIN OF 2 IN. (51 MM) LARGER THAN THE

SLEEVE DIAM. THE SHEET METAL SLEEVE IS TO BE CAST IN PLACE AND MAY EXTEND A MAX OF 2 IN. (51 MM) ABOVE THE TOP SURFACE OF THE CONCRETE FLOOR, EXCEPT THAT WHEN SLEEVE IS GREATER THAN NOM 13 IN. (330 MM) DIAM, SLEEVE SHALL BE INSTALLED FLUSH WITH BOTH SURFACES OF FLOOR.

3. THROUGH-PENETRANTS — ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND PERIPHERY OF OPENING OR SLEEVE SHALL BE MIN 0 IN. (POINT CONTACT).

SEE TABLE IN ITEM 4B FOR MAX ANNULAR SPACE. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED:

A. STEEL PIPE — NOM 30 IN. (762 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.

B. IRON PIPE — NOM 30 IN. (762 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.

C. CONDUIT — NOM 6 IN. (152 MM) DIAM (OR SMALLER) RIGID STEEL CONDUIT.

D. CONDUIT — NOM 4 IN. (102 MM) DIAM (OR SMALLER) ELECTRICAL METALLIC TUBING (EMT).

E. COPPER TUBING — NOM 6 IN. (152 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER

TUBING.

F. COPPER PIPE — NOM 6 IN. (152 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.

4. FIRESTOP SYSTEM — THE FIRESTOP SYSTEM SHALL…