24_04_15 Addendum 2 _ Revised Proposal.pdf
PDF 349 KB Posted
- Attached to
- RFP 2314 DARIEN DDA DOCK IMPROVEMENTS
- Solicitation number
- PE-66136-NONST-2024-000000001
- Issued by
- Long County, Georgia
About this file
This document is an Addendum No. 2 to RFP No. 2314 for a Dock Improvements Project issued by the Darien Downtown Development Authority, located in Darien, Georgia. The RFP requests proposals to furnish all labor, equipment, materials, and other appurtenances for dock improvements on the Darien River, west of US Highway 17. The Addendum revises the Proposal Sheet, including changes to line items such as the walkway, ramp, floating docks, and piles. Contractors are required to submit the revised Proposal Sheet by April 15, 2024. The project must comply with the applicable federal, state, and local statutes, ordinances, and regulations, as well as the CMPA Permit #830.
The Proposal Sheet includes pricing for various components of the project, including general items, existing items to be removed, and proposed new items such as wharf walkway sections, fixed walkways, ramps, and floating docks. Contractors are also provided the option to propose alternative pile specifications and quantities. The Base Bid Total and Totals with alternative pile options must be submitted. Testing requirements, if any, are the responsibility of the contractor and not required unless the information is not known.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
301 Sea Island Road Suite 10, St. Simons Island, GA 31522 912-638-9681 Office
Addendum No. 2
April 15, 2024
Darien Downtown Development Authority
PO Box 452
Darien, GA 31305
Re: Dock Improvements Project
RFP No. 2314
Dated February 29, 2024
This Addendum amends the Proposal Sheet from RFP #2314 revised on March 29, 2024.
A. CHANGES TO THE PROPOSAL SHEET– Please fill out and submit the attached Proposal Sheet with Revision Date: April 15, 2024. Pages 19-20 of the Revised RFP dated March 29, 2024, will be replaced with the Proposal Sheet on the following page.
Darien Downtown Development Authority- Dock Improvements RFP No. 2314 – Addendum #2 Revised Proposal Sheet 4-15-2024
PROPOSAL SHEET
FROM:________________________________________________________________________
Line Item
No.
Item Description Qty Unit Unit Price Amount
GENERAL
1. Mobilization 1 LS
2. Equipment Cost 1 LS
EXISTING
3.
Walkway to be removed and disposed of along with timber piles
1 LS
4. Ramp to be removed and disposed of 1 LS
5.
Floating Dock to be removed and disposed of along with concrete piles
1 LS
*PROPOSED
6.
Wharf Walkway Section Frame: match existing
Decking: match existing
111 SF
7.
Wharf Walkway Section Handrails Match existing
34 LF
8.
Wharf Walkway Section Piles:
14” diameter Timber Piles, 50’ long
6 EA
9.
Fixed Walkway: 6’ x 86’ Frame: Aluminum
Decking: Trex, WearDeck or similar man-made composite material
516 SF
10.
Fixed Walkway Piles:
14” diameter Timber Piles, 65’ long
14 EA
11.
Fixed Walkway Handrails Aluminum or man-made composite horizontal railings. One middle railing and one top railing
172 LF
12.
Ramp 1 and 2: 4’ x 30’ Aluminum ramp with aluminum railings
240 SF
13.
Floating Dock 1: 10’ x 126’ Frame: Aluminum
Decking: Trex, WearDeck or similar man-made composite material
1,260 SF
14.
Floating Dock 2: 12’ x 126’ Frame: Aluminum
Decking: Trex, WearDeck or similar man-made composite material
1,512 SF
15.
Floating Dock Piles:
16’’ Diameter Concrete Piles, 80’ long
16 EA
15A.
Floating Dock Piles (alternative A):
Fill in alternative pile specs and quantity:
EA
Diameter: ______________IN
Material: Timber
Length of Piles: __________FT
QTY:________
(# of piles)
15B.
Floating Dock Piles (alternative B) Fill in alternative pile specs and quantity:
EA
Diameter: ______________IN
Material: _____________________________
Length of Piles: __________FT
QTY:________
(# of piles)
**TESTING (if not needed enter N/A)
16. Boring Test 1 LS
17. Wind Test 1 LS
BASE BID TOTAL ( 15. - Concrete Piles) $ _______________________
TOTAL (w/alt. 15A - Timber Piles) $ _______________________
TOTAL (w/alt. 15B - Contractor’s choice of Piles) $ _______________________
* Structural Design and Submittals including, but not limited to, dock specifications, standards, and/or plans for each item listed in the Proposed Section must be submitted in the sealed proposal.
** Testing for the design of this project is the responsibility of the contractor and is not required unless the information needed is not known. Please note that boring test results (and possibly wind test results) for the proposed bridge project on SR25/US17 over Darien River are public records and may be acquired directly from GDOT.
Note:
Please write in “No bid” if the contractor does not wish to bid on an alternative item
Note:
The project must comply, as applicable, for areas permitted by the CMPA Permit #830, with all other federal, state, and local statutes, ordinances, and regulations. All plans, documents and materials contained in the CMPA Permit #830, are a part of this project.
File details come from the government source that posted it. Updated .