23RM147 SWICC Kettle Specs~2.pdf
PDF 200 KB Posted
- Attached to
- SWICC R/M Dietary Kettle
- Solicitation number
- 24-426DOC-SWICC-B-37798
- Issued by
- St. Clair County, Illinois
About this file
This document contains specifications for gas-fired stationary kettles manufactured by Cleveland Range. The kettles are available in 40, 60, 80, and 100 gallon capacities and feature a high-efficiency power burner heating system, automatic ignition, insulated heat exchanger, solid state controls, and a stainless steel interior. Standard features include a pressure/vacuum gauge, level-adjustable legs, and a spring-assisted hinged cover. Optional accessories include a water faucet, cooking baskets, and a kettle accessory kit. The kettles are compliant with applicable AGA, CSA, CE, NSF, and ASME standards. Detailed dimensional drawings and specifications are provided for each model. Shipping weights and dimensions are also included. The document does not contain information about a state or local contract opportunity.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 23RM147 SWICC Kettle Contract.docx | DOCX document | |
| FY 24 Standard Terms and Conditions v.23.2_27.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project
Item
Quantity
FCSI Section 11400
Approved
Date
760 Beta Drive, Unit D May1eld Village, Ohio 44143
Tel 1.216.481.4900 Fax 1.216.481.3782 Email steam@clevelandrange.com www.clevelandrange.com
G as K e ttle s
LEG TYPE, GAS-FIRED KETTLES
STATIONARY, 2⁄3 STEAM JACKETED “SPLASH PROOF SERIES”
40, 60, 80 or 100 GALLONS (150, 225, 300 or 337 LITERS)
Section 6, Page 11
5640A 02 / 2021
Standard Features
• High efficiency Power Burner Heating System (62% to 65% efficiency)
• Fast Heat-up and Recovery Time, 140M BTU’s on 40 gallon models, 190M BTU’s on 60 gallon and larger
• Insulated Heat Exchanger
• Automatic Ignition System
• Steam jacket permanently filled with treated, distilled water.
Venting and/or refilling not required
• Solid State Controls, for Temperature and Low Water Safety, in a plug-in Control Module
• Control Panel includes:
• Precise, consistent temperature control: less than ± 1°C variance (ideal for simmering).
• L.E.D. Indicators for Heat Cycle and Low Water
• Warning.
• Power “on/off” Switch
• Front mounted combination Pressure/Vacuum Gauge
• Type 316 Stainless Steel with #4 finish on kettle
• 2˝ diameter Tangent Draw-Off Valve with Drain Strainer
• Support Legs with level adjustable feet, flanged for floor bolting
• Spring-assisted, hinged, rotatable, domed Stainless Steel Cover
• 50 PSI Steam Jacket Rating and Safety valve
• Standard voltage is 115 volts, 60 Hz, single-phase, supplied with cord and plug
• Standard for natural gas operation
• Faucet Mounting Bracket (FBK)
• Typical approvals include AGA, CSA, CE, NSF and ASME
Options & Accessories
• Hot and Cold Water Faucet with Swing Spout (DPK)
• Cooking Baskets and Tri-Basket Supports (BS and TBS)
• Drain Strainers (DS-)
• 3" diameter Tangent Draw-off Valve with Drain Strainer (TD3)
• Kettle Accessory Kit (KAK) includes:
• Clean-up Brush (CB) • 36˝ Kettle Paddle (KP)
• 36˝ Kettle Whip (KW) • 36˝ Kettle Brush
• Draw-Off Brush (DB) • 24 oz. Ladle (KL)
• Automatic Water Meter (GMF or LMF)
• Measuring Strip (MS)
• Option for Propane Gas operation
• Correctional Package
• Heat Deflector Shield (HS001)
Models
• KGL-40 • KGL-80
• KGL-60 • KGL-100
Short Form Specifications Shall be CLEVELAND, Gas-fired Stationary Kettle, Model KGL-_____ ; _____ gallons. 2⁄3 Steam
Jacketed, Power Burner Heating System, Insulated
Heat Exchanger, 50 psi Steam Jacket Rating. Infinite
Variable Temperature Control, L.E.D. indicators for
Heat Cycle and Low Water Warning, spring-assisted
Cover, 2˝ Tangent Draw-off Valve with Drain
Strainer, Automatic Ignition System. 316 Stainless
Steel Interior.
KE004046-71
80 80
Christopher.J.Smith Highlight
Christopher.J.Smith Highlight
Christopher.J.Smith Highlight
760 Beta Drive, Unit D May1eld Village, Ohio 44143
Tel 1.216.481.4900 Fax 1.216.481.3782 Email steam@clevelandrange.com www.clevelandrange.com
G as
K e tt le s
Section 6, Page 12 02 / 2021
(NOT TO SCALE)
CAPACITIES: (in 8 oz. servings, other sizes may be calculated)
40 Gallon / 150 liters . . . 640 servings 60 Gallon / 225 liters . . . 960 servings 80 Gallon / 300 liters . . . 1280 servings 100 Gallon / 375 liters . . . 1600 servings
1Ú2ý dia. Soft Copper Tubing (each)
When ordered with optional faucet.
WATERELECTRIC
120V-1 Phase, 60 Hz, 10 amps
GAS CLEARANCEH
RIGHT = 3ý LEFT = 3ý REAR = 3ý
Allow 6ý space minimum from rear and sides when located near combustible walls. 12" recommended on right side for service
NATURAL PROPANE
Piping: 3Ú4ý N.P.T. Piping: 3Ú4ý N.P.T.
Supply pressure: Supply pressure:
4.00ý W.C. minimum 4.00ý W.C. minimum 14.00ý W.C. maximum 14.00ý W.C. maximum
Manufacturer must be notified if unit will be operated above 2,000 ft. altitude.
C
H CB.T.U. RATING
40 gal. 140,000
60 gal.
80 gal. 190,000
100 gal.
G
(COVER
OPEN)
3" (77 mm)
MINIMUM
CLEARANCE
F
3 (77 mm)
L
M
N O
P
H
J
K
FLOOR DRAIN
12" (305 mm) WIDE x 12" (305 mm) LONG
UNIT SHOWN WITH OPTIONAL 2" TANGENT DRAW-OFF VALVE,
SPRING ASSIST COVER AND HOT & COLD WATER FAUCET.
75º
H C
E
D
A
S
C
4" (102 mm)
B
T (I.D.)
RECOMMENDED
FLOOR SLOPE
1" (26 mm) per 4' (1220 mm)
PIPE DRAIN RECOMMENDED
min. valve size plus 1" (26 mm)
4" (102 mm)
RECOMMENDED
9/16" 14 mm
120º
TYP
1" (25 mm)
MAX. ADJUSTMENT
1 5/8" (42 mm) Ø
FLANGED FOOT DETAIL
7/16" (11 mm) Ø
3 HOLES ON
3 1/8" (80 mm) Ø B.C.D.
4 7/8" 124 Ø mm
VALVE
OPENING
DIMENSIONS
GALS./
LITERS A B C D E F G H J K L M N O P S T I.D.
40 IN 35 1/8 37 32 1/4 40 1/2 9 1/4 16 71 1/2 9 9/16 17 3/4 25 15/16 10 3/8 18 5/8 26 7/8 28 1/2 4 5/8 24 1/2 26 150 mm 893 940 820 1029 235 407 1817 243 451 659 264 474 683 724 118 648 661
60 IN 38 1/4 39 34 1/4 43 1/2 8 3/4 14 1/4 75 8 15/16 19 1/8 29 5/16 10 3/8 18 5/8 27 7/8 30 1/4 5 1/4 27 29 1/2 225 mm 972 991 870 1105 223 362 1905 228 486 745 264 474 709 769 134 686 750
80 IN 41 5/8 42 3/8 35 1/2 45 1/2 8 3/4 15 1/2 79 9 1/4 20 3/4 32 1/4 10 3/8 18 5/8 29 5/8 31 1/2 6 5/8 29 33 300 mm 1058 1077 902 1156 223 394 2007 235 528 820 264 474 753 801 169 737 839
100 IN 44 43 1/2 36 1/2 47 1/2 8 3/4 15 1/2 83 1/2 9 1/8 21 7/8 34 5/8 10 3/8 18 5/8 31 1/4 32 1/2 7 1/2 30 1/2 35 1/2 375 mm 1118 1105 928 1207 22.3 394 2121 232 556 880 264 474 794 826 191 775 902
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L/NSF#4 and CSA (AGA, CGA).
Shipping Weights & Dimensions
Model - KGL-40 Weight - 454 lbs
Width - 44” Depth - 44” Height - 54”
KGL-40 Weight - 510 lbs Width - 44” Depth - 44” Height - 54”
KGL-40 Weight - 597 lbs Width - 56” Depth - 55” Height - 59”
Christopher.J.Smith Highlight
Christopher.J.Smith Highlight
Christopher.J.Smith Highlight
Christopher.J.Smith Highlight
File details come from the government source that posted it. Updated .