2352 - CMU Monument Hall Closets - Review Set.pdf

PDF 2 MB Posted

Attached to
CMU 2837 Monument Hall Upgrade
Solicitation number
1021-25-1 CMU 2837 Monument Hall Upgrade
Issued by
Larimer County, Colorado

About this file

This architectural review set, prepared by Kraai Design Architecture for Colorado Mesa University (CMU), details the design plans for Monument Hall Closets renovations at 1102 Elm Walk in Grand Junction, Colorado. The document provides comprehensive architectural drawings for a closet upgrade project targeting the 46,695 sq ft residence hall with 92 bedrooms and 2 apartments. The plans specify interior modifications including new closet construction, with detailed wall types, materials (such as 3 5/8" metal studs, gypsum board, and sound batt insulation), and specific installation requirements like heavy-duty closet rods and MDF board shelving. The project is scheduled to commence on 19 May 2025 and must be completed by 28 July 2025.

The architectural review set includes technical specifications for wall construction, floor plans, elevations, and general contractor notes that outline comprehensive requirements for material selection, installation standards, and project execution. While specific budget details are not disclosed, the documents indicate the project will be managed through Mesa County's Building Department, with the general contractor yet to be determined. The plans emphasize strict adherence to building codes, precise measurements, and coordination among various trades, with explicit instructions for submitting shop drawings, maintaining site cleanliness, and ensuring structural integrity during the renovation process.

View the file

Other files

File Type Posted
Sheet 015 mod.PDF PDF
Sheet 017 mod.PDF PDF
cmu-solicitation-instructions-rev-2021-05-07 (1).pdf PDF
CMU 2837 Monument Hall Uprade Bid.pdf PDF
Sheet 016 mod.PDF PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SYMBOL LEGEND - ENLARGED PLAN

A1.1

A

101A

A1.1

TYP

AL HM

- GRID LINE

- DOOR TAG

- WINDOW TAG

- CENTERLINE

- WALL ABOVE OR

HIDDEN LINE

- MATCH LINE

- ROOM TAG

- ELEVATION

SYMBOL

- SECTION

SYMBOL

- KEYNOTE SYMBOL

LVT -LUXURY VINYL TILE

CLG -CEILING

WH -WATER HEATER

FURN -FURNACE

CONC -CONCRETE

MSTR -MASTER

GENERAL FLOOR PLAN NOTES

FLOOR PLAN TAG NOTES

A1.1

- CALLOUT

SYMBOL

A. REFER TO MEP FOR HVAC, LIGHTING, POWER SIZE SIZE AND

LOCATIONS

B. REFER TO STRUCTURAL DRAWINGS FOR STRUCTURAL BEAMS,

WALLS, COLUMNS SIZE AND LOCATIONS

C. REFER TO SHEET A0.0 FOR PUBLIC SPACES ADA STANDARDS FOR

ACCESSIBLE DESIGN

D. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION

THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING

CLARIFICATION FROM THE ARCHITECT PRIOR TO CONTINUING

CONSTRUCTION.

E. ITEMS NOT NOTED ON THE DRAWINGS SHALL BE CONSIDERED

THE SAME AS NOTED ITEMS WHICH ARE GRAPHICALLY

REPRESENTED IN THE SAME MANNER.

F. PROVIDE BLOCKING FOR ALL WALL EQUIPMENT, TOILET

ACCESSORIES, MILLWORK AND OTHER WALL MOUNTED ITEMS.

SEE ELEVATIONS AND EQUIPMENT SPECIFICATIONS FOR

ADDITIONAL INFORMATION.

G. CONTRACTOR SHALL CAULK AT THE INTERFACE OF INTERIOR

FACES OF DOOR FRAMES WITH ADJACENT MATERIALS THOUGH

JOINT MAY NOT BE VISIBLE.

H. PROVIDE TRANSITION STRIPS BETWEEN FLOOR MATERIALS OF

DISSIMILAR HEIGHTS. CENTER TRANSITION STRIPS UNDER DOORS

OR OTHER PLACES OUT OF SIGHT.

I. PROVIDE POSITIVE SLOPE ON ALL FLOOR DRAINS, MINIMUM

OF1/8” PER FOOT. SLOPE FLOOR ALL AROUND FROM ADJACENT

WALLS TO FLOOR DRAINS, DO NOT DEPRESS ONLY THE AREA

IMMEDIATELY AROUND THE DRAIN.

J. REFER TO THE MECHANICAL, ELECTRICAL, AND PLUMBING

DRAWINGS FOR THE LOCATIONS OF PIPING, VENTS, DUCTS,

CURBS, FANS AND OTHER ITEMS WHICH PENETRATE THE ROOF

PLANE.

K. DOOR JAMB LOCATION OFF FACE OF WALL IS 4", TYPICAL,

UNLESS NOTED OTHERWISE.

1. FURNITURE BY OTHERS

2. 16" X 48" X 3/4" MDF BOARD, PNT. WHITE

3. 1X4 BLOCKING, PNT. WHITE

4. HEAVY DUTY CLOSET ROD W/ HEAVY-DUTY

POLE SOCKETS. PRE-FINISHED WHITE.

Room name

- NEW CLOSET LOCATION

8' - 1"

4' - 0" 1" 4' - 0"

A1.1

2A

2B

* MIRRORED UNITS THROUGHOUT *

0' - 0"

LEVEL

6' - 0"

T.O. SHELF

7' - 0 3/4"

T.O. SHELF

32 44

* MIRRORED UNITS THROUGHOUT *

2A

IN

TE

R

IO

R

IN

TE

R

IO

R

5/8" GYP. BD

3 5/8" MTL. STUDS

@ 16" O.C.

SOUND BATT

INSULATION

5/8" GYP. BD

2B

IN

TE

R

IO

R

IN

TE

R

IO

R

3/4" MDF BOARD, PNT.

WHITE OR PER CMU

DIRECTION

NOT FOR CONSTRUCTION

SCALE:

SHEET NO:

DATE:

2394 PATTERSON ROAD, SUITE 201

GRAND JUNCTION, CO 81505

126 ELK AVENUE, UNIT 1

CRESTED BUTTE, CO 81224

T: 970.712.5045

REVISION(S):

PROJECT NO:

SHEET NAME:

KRAAI DESIGN

ARCHITECTURE

As indicated

A1.1

04/08/2025

M O

N U

M E N

T H

A

LL

C

LO

S E

TS

E

LM

W A

LK

G

R A

N D

J U

N C

TI

O

N C

O

REVIEW SET

MAIN LEVEL PLAN,

ELEVATIONS,

SCHEDULES

1/4" = 1'-0"A1.1

1 TYPICAL CLOSET LAYOUT

3/8" = 1'-0"A1.1

2 I.E. CLOSET - FRONT

WALL TYPES

# DATE COMMENTS

ARCHITECT

2394 Patterson RD, Suite 201

Grand Junction, CO 81505

T: 970.712.5045 www.kraaidesign.com

CONSULTANTS

GOVERNMENT

MESA COUNTY

BUILDING DEPARTMENT

200 S. SPRUCE ST.

GRAND JUNCTION, CO 81501

T: 970.244.1631

KRAAI DESIGN ARCHITECTURE

VICINITY MAP

SHEET INDEX

REVISION

ELEVATION

COLUMN GRID LOCATION

CENTER LINE

LINE OF WALL ABOVE

OR HIDDEN LINE

BREAK LINE

MATCH LINE

ROOM NAME

ROOM NUMBER

INTERIOR WALL ELEVATION

REFERENCE DRAWING

REFERENCED SECTION

NUMBER SHEET NUMBER

REFERENCED DETAIL

NUMBER SHEET NUMBER

A101

A

101A

Room

A101

TYP

A101

TYP

ANGLE

DIAMETER

PERPENDICULAR

PLATE

PLUS OR MINUS

FLOOR DRAIN

FIRE EXTINGUISHERFE

FD

100' 0"

TOP OF WALL

AL HM

LEGEND ABBREVIATION SYMBOL

GENERAL NOTES

ABV above

ACC accessories

ADJ adjacent

AFF above finished floor

ALT alternate

AL aluminum

APC acoustical panel ceiling

ARCH architect (ural)

ASPH asphalt

A/C air conditioning

BCS baby changing station

BD board

BLDG building

BLKG blocking

B.O. bottom of

BRG bearing

CBU cemetitious backer unit

CG corner guard

CJ control joint

CLG ceiling

CLR clear (ance)

CMU concrete masonry unit

COL column

CONC concrete

CONT continuous or continue

CORR corridor

CPT carpet (ed)

CSMT casement

CT ceramic tile

CTR center

CWOG center wall on grid

DBL double

DEMO demolish / demolition

DF drinking fountain

DIM dimension (s)

DIR direction

DISP dispenser

DN down

DR door

DS downspout

DTL detail

DWG drawing

DWR drawer

E east

EA each

EC evaporative cooler

EG etched glass/glazing

EIFS exterior insul finish sys

EJ expansion joint

EL elevation

ELEC electric (al)

EM emergency

EWC electric water cooler

EWG end wall corner guard

EQ equal

EXG existing

EXH exhaust

EXP exposed

EXT exterior

FBO furnished by owner

FD floor drain

FDN foundation

FE fire extinguisher

FEC fire extinguisher cabinet

FEP finished end panel

FFE finished floor elevation

FIN finish

FLG flashing

FLR floor (ing)

FLUR fluorescent

FO face of

FOF face of finish

FRMG framing

FRP fiber reinforced plastic

FT foot (feet)

FTG footing

GA gage, gauge

GAL gallon

GALV galvanized

GB grab bar

PTN partition

PVC polyvinyl cholride

PVMT pavement

PWD plywood

QT quarry tile

R riser, radius

RB rubber base

REC recycling

RCMD recommend (ed) (ations)

RE reference

REF refrigerator

REIN reinforce (d) (ing)

REQ'D required

RQMT(S) requirement(s)

REV revision (s), revised

RD roof drain

RFG roofing

RH robe hook

RM room

RO rough opening

ROW right of way

RR restroom

RTU roof top unit

RUB rubber

S south

SAG susp acoustic grid

SC shower curtain rod & hooks

SCH schedule

SD soap dispenser

SHT sheet

SHTG sheathing

SIM similar

SND sanitary napkin dispenser

SNV sanitary napkin vendor

SPEC specification

SPKR speaker

SQ square

SS solid surface

SST stainless steel

STD standard

STL steel

STOR storage

STR structural

SUSP suspended

T tread

TB towel bar

TBD to be determined

TEL telephone

T.O. top of

TOC top of concrete

TOS top of steel

TOW top of wall

TPD toilet paper dispenser

TS tube steel

TYP typical

T&G tongue and groove

UNO unless noted otherwise

VB vapor barrier

VCT vinyl composition tile

VERT vertical

VIF verify in field

VM vending machine

VNL vinyl sheet

VTR vent through roof

W west, wide, width

W/ with

WB wood base

WC watercloset

WD wood

WDW window

WF wide flange

WG wire glass

W/O without

WP waterproof (ing)

WR waste receptacle

WRB weather resistive barrier

WWM welded wire mesh

ABBREVIATIONS

PROJECT LOCATION

GC general contractor

GL glass, glazing

GWB gypsum wallboard

GYP gypsum

HAS headed anchor stud

HB hose bibb

HCP handicap (ed)

HDR header

HDW hardware

HM hollow metal

HOR horizontal

HSS hollow structural sections

HT height

HVAC heating /ventilation / air conditioning

HWD hardwood

INCL include (d) (ing)

INSUL insulate (d) (ing)

INT interior

INV invert

JST joist

JT joint

L length, angle

LAM laminate (d)

LAV lavatory

LB pound

LF lineal foot

LG laminated glass, glazing

LIN linoleum

LT light

MA match

MAS masonry

MATL material

MAX maximum

MB marker board

MDF medium density fiberboard

MECH mechanic (al)

MFR manufacture (r) (d)

MH manhole

MIN minimum

MISC miscellaneous

MLD molding, moulding

MO masonry opening

MT mount (ed) (ing)

MTL metal

N north

N/A not applicable

NIC not in contract

NOM nominal

NTS not to scale

NECY necessary

OC on center (s)

OD outside diameter

OFCI owner furnished, contractor installed

OFD overflow drain

OFOI owner furnished, owner installed

OH overhead

OPG opening

OPH opposite hand

OPP opposite

OSB oriented strand board

OTS open to structure

PB particle board

PERF perforate (d)

PERIM perimeter

PLAM plastic laminate

PLT plate

PNL panel

PNT paint (ed)

PR pair

PROJ projector, projection

PSF pounds per square foot

PSI pounds per square inch

PT pressure treated

PTD paper towel dispenser

DOOR NUMBER

WINDOW TYPE

BASIC WALL TYPE

TAG NOTE

1. CONTRACTOR SHALL BE GOVERNED BY THE CURRENT EDITION OF

ALL CODES AND REGULATIONS HAVING JURISDICTION OVER

ASPECTS OF THIS CONSTRUCTION PROJECT.

2. WRITTEN DIMENSIONS AND EXISTING CONDITIONS SHALL BE

VERIFIED IN THE FIELD BY THE CONTRACTOR AND/OR THE SUB-

CONTRACTORS. DO NOT SCALE DRAWINGS. IF FURTHER

CLARIFICATION IS REQUIRED, CONTACT KDA AND PROVIDE FIELD

DIMENSIONS AS REQUIRED TO ASSIST WITH CLARFICATION.

3. ANY DISCREPANCY IN DIMENSIONS AND/OR DRAWINGS AND/OR

GRAPHIC REPRESENTATION AND/OR FIELD MEASUREMENTS SHALL

BE BROUGHT TO THE ATTENTION OF KDA PRIOR TO THE

COMMENCEMENT OF WORK.

4. THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND

COPYRIGHT © OF KDA AND SHALL NOT BE USED ON OTHER WORK

EXCEPT BY WRITTEN AGREEMENT WITH KDA.

5. DUTY OF COOPERATION: RELEASE OF THESE PLANS ANTICIPATES

FURTHER COOPERATION AMONG THE OWNER, CONTRACTOR, AND

KDA. ALTHOUGH KDA AND ITS CONSULTANTS HAVE PERFORMED

THEIR SERVICES WITH DUE CARE AND DILIGENCE, THEY CANNOT

GUARANTEE PERFECTION. ANY AMBIGUITY OR DISCREPANCY

DISCOVERED SHALL BE REPORTED IN WRITING TO KDA WITHIN TEN

(10) WORKING DAYS FROM THE ISSUANCE OF PLANS. FAILURE TO

COOPERATE BY SIMPLE NOTICE TO KDA SHALL NOT RELIEVE THE

CONTRACTOR FROM RESPONSIBILITY FOR ALL CONSEQUENCES.

CHANGES MADE FROM THE PLANS WITHOUT THE CONSENT OF KDA

ARE UNAUTHORIZED, AND SHALL RELIEVE KDA OF RESPONSIBILITY

FOR ALL CONSEQUENCES ARISING OUT OF SUCH CHANGES.

6. IF KDA, AS A CLAIMANT OR A DEFENDING PARTY, IS AT ANYTIME A

PARTY TO LITIGATION INVOLVING ANY CLAIM RELATED TO WORK

CONTAINED IN THESE DRAWINGS, AND SHOULD CLAIMANT NOT

PREVAIL SUBSTANTIALLY AGAINST DEFENDING PARTY IN SUCH

LITIGATION, ALL LITIGATION EXPENSES, WITNESS FEES, COURT COSTS

AND ATTORNEYS FEES INCURRED BY THE DEFENDING PARTY IN

DEFENDING AGAINST SUCH A CLAIM, SHALL BE PAID BY THE

CLAIMANT.

7. ALL PRODUCTS SHALL BE INSTALLED PER MANUFACTURER'S

RECOMMENDATIONS.

8. THE CONTRACTOR SHALL INCLUDE ANY WORK REQUIRED TO MAKE

THE END RESULT BUILDING OPERATIVE AND OCCUPIABLE. IF

EQUIPMENT, MATERIAL, AND/OR INTENT ARE NOT DETAILED IN

DRAWINGS OR SPECIFICATIONS BUT ARE OBVIOUSLY REQUIRED AS

INDUSTRY STANDARD FOR OPERATIVE CONDITIONS, THIS WORK

SHALL BE INCLUDED IN BASE BID. IF THE OWNER DOES NOT ACCEPT

THE CONTRACTOR'S SELECTION, THE ADDITIONAL COST (TO THE

CONTRACTOR) OF THAT EQUIPMENT OR MATERIALS CHOSEN BY THE

OWNER OR KDA WILL BE OFFSET BY A CHANGE ORDER.

9. TYPOGRAPHICAL ERRORS OR ERRORS OF SPELLING SHALL BE

BROUGHT TO THE ATTENTION OF KDA FOR CLARIFICATION.

INTERPRETATION OF THE MEANING OF MIS-TYPED OR MISSPELLED

WORDS WITHOUT CLARIfiCATION FROM KDA WILL BE DONE BY THE

CONTRACTOR WITH ACCEPTANCE OF RESPONSIBILITY FOR THAT

INTERPRETATION AND ALL CONSEQUENCES ARISING THEREFROM.

10. NOTES: ALL DIMENSIONS ARE TO FACE OF STUD OR CONCRETE

WALL OR CENTER LINE OF CONSTRUCTION AS INDICATED (TYPICAL

UNLESS OTHERWISE INDICATED).

11. THE TERM "PROVIDE" AS USED HEREIN SHALL MEAN THAT

CONTRACTOR SHALL FURNISH AND INSTALL SAID ITEM,

CONSTRUCTION, EQUIPMENT, MATERIALS, ETC. FOR A COMPLETE

FINISHED INSTALLATION.

12. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR

COORDINATION OF ALL TRADES DOING WORK FOR THE PURPOSE

OF COORDINATION WITH OWNER AND OWNER'S SUB-

CONTRACTORS REGARDING INSTALLATION AND PROVISIONS FOR

ALL EQUIPMENT, MATERIALS, AND CONSTRUCTION INDICATED BY

"OWNER" OR BY "OTHERS" ON THESE DOCUMENTS.

13. KDA ACCEPTS NO RESPONSIBILITY FOR ANY STRUCTURAL

INFORMATION CONTAINED IN THESE PLANS. CONTRACTOR SHALL,

PRIOR TO CONSTRUCTION, VERIFY ALL STRUCTURAL ENGINEERING

INFORMATION AND REQUIREMENTS WITH A LICENSED STRUCTURAL

ENGINEER. FAILURE TO DO SO INDICATES THE CONTRACTORS

ACCEPTANCE OF RESPONSIBILITY FOR ALL CONSEQUENCES

ARISING THEREFROM. CONTRACTOR SHALL BE RESPONSIBLE FOR

PROVIDING THE STRUCTURAL ENGINEER OF RECORD WITH ALL

STRUCTURAL DESIGNS DONE BY TRUSS MANUFACTURERS,

ENGINEERED FLOOR JOIST DESIGNERS AND OTHER SPECIALIZED

ENGINEERING SERVICES. THE STRUCTURAL ENGINEER OF RECORD

SHALL BE RESPONSIBLE FOR REVIEWING AND APPROVING SUCH

INFORMATION AND FOR NOTIFYING DESIGNER OF ANY REQUIRED

MODFICATIONS.

14. THE CONTRACTOR WARRANTS TO KDA THAT THEY POSSES THE

PARTICULAR COMPETENCE AND SKILL IN CONSTRUCTION

NECESSARY TO BUILD THIS PROJECT WITH THE PLANS AND

SPECIFICATIONS CONTAINED HEREIN. IN THE EVENT ADDITIONAL

DETAIL OR GUIDANCE IS NEEDED BY THE CONTRACTOR, HE SHALL

IMMEDIATELY NOTIFY KDA. FAILURE TO GIVE A SIMPLE NOTICE

SHALL RELIEVE THE DESIGNER OF RESPONSIBILITY FOR THE

CONSEQUENCES.

15. ANY CORRESPONDENCE BETWEEN OWNER/ CONTRACTOR/ AGENT

AND ANY PERMITTING AGENCY (CITY, COUNTY, ETC.) MUST BE

BROUGHT TO THE ATTENTION OF KDA IMMEDIATELY. CHANGES TO

THE CONSTRUCTION SETS MAY BE REQUIRED. FAILURE TO DO SO

RELEASES KDA FROM ANY RESPONSIBILITY OR LIABILITY.

16. CONTRACTOR OR OWNER SHALL CONFIRM, WITH A LICENSED

SURVEYOR, PRIOR TO CONSTRUCTION THAT PLANS AND

ELEVATIONS COMPLY WITH ALL APPLICABLE SETBACKS, ALLOWABLE

MAXIMUM HEIGHT AND DRAINAGE STANDARDS AS OUTLINED IN

THE SOILS REPORT AND/OR SUBDIVISION GUIDELINES, ETC.

CONTRACTOR/ OWNER SHALL COFIRM THAT PERMITTING AGENCY

IS INFORMED OF ALL SUCH INFORMATION OR ADDITIONAL

INFORMATION CONTAINED IN CONSTRUCTION PLANS OR ANY

SUBSEQUENT REVISIONS. FAILURE TO DO SO RELEASES KDA FROM

ANY RESPONSIBILITY OR LIABILITY. ANY LOCATION (SETBACK) OR

HEIGHT SURVEY REQUIRED BY THE PERMITTING AGENCY SHALL BE

PERFORMED IMMEDIATELY AFTER CONSTRUCTION OF THE ELEMENT

IN QUESTION (FOUNDATION OR FRAMING HEIGHT AND

LOCATION). SAID SURVEY SHALL BE DELIVERED TO THE PERMITTING

AGENCY PRIOR TO PROCEEDING WITH CONSTRUCTION.

17. DELIVERY AND STORAGE OF MATERIALS AND EQUIPMENT STAGING

AREAS ARE TO BE COORDINATED WITH OWNER.

18. THE CONSTRUCTION SITE IS TO BE KEPT FREE OF DEBRIS.

19. CONTRACTOR SHALL PROVIDE ELECTROLYTIC PROTECTION

BETWEEN DISSIMILAR METALS WHERE THEY OCCUR TO PREVENT

ELECTROLYSIS/ CORROSION.

20. CONTRACTOR SHALL TAKE CARE TO PROVIDE PROTECTION FOR

NEWLY INSTALLED AND EXISTINGWORK AND FINISHES.

21. THE GENERAL BUILDING PERMITS SHALL BE PAID FOR BY THE OWNER

AND SECURED BY THE GENERAL CONTRACTOR. ALL OTHER

REQUIRED PERMITS SHALL BE SECURED AND PAID FOR BY THE

CONTRACTOR OR SUBCONTRACTOR DIRECTLY RESPONSIBLE. ALL

REQUIRED CITY AND COUNTY LICENSES SHALL BE ACQUIRED AND

PAID FOR BY THE INDIVIDUAL TRADES.

22. ALL CONTRACTORS SHALL HAVE VALID CERTIFICATES OF

WORKMAN'S COMPENSATION ON FILE WITH THE APPROPRIATE

AGENCIES. INSURANCE REQUIREMENT MUST BE MET PER LEASE

AGREEMENT.

23. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE

ALL EXISTING UTILITIES, WHETHER SHOWN HEREIN OR NOT, AND TO

PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR

ALL EXPENSE FOR THE REPAIR OR REPLACEMENT OF UTILITIES AND

ALL OTHER PROPERTY DAMAGED BY OPERATIONS IN

CONJUNCTION WITH EXECUTION OF WORK.

24. CONTRACTOR SHALL PROVIDE TEMPORARY FIELD OFFICE,

TELEPHONES, FAX MACHINE, TEMPORARY SECURITY FENCE, WATER,

POWER, AND TOILET FACILITIES. COORDINATE LOCATIONS WITH ALL

APPROPRIATE AGENCIES. FIELD OFFICE SHALL ALSO CONTAIN

CURRENT COPIES OF ALL GOVERNING BUILDING CODES AND

AMENDMENTS.

25. CITY APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL

NOT BE USED BY WORKMEN. ALL CONSTRUCTION SETS SHALL

REFLECT THE SAME INFORMATION. THE CONTRACTOR SHALL ALSO

MAINTAIN, IN GOOD CONDITION, ONE (1) COMPLETE SET OF

PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON

THE PREMISES AT ALL TIMES. THESE ARE TO BE UNDER THE CARE OF

THE JOB SUPERINTENDENT.

26. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY

OF THE SITE WHILE JOB IS IN PROGRESS UNTIL WORK IS COMPLETE.

27. CONTRACTOR SHALL MAINTAIN THE JOB SITE IN A CLEAN AND

ORDERLY MANNER. ALL DEBRIS SHALL BE REMOVED FROM

PREMISES AND ALL AREAS SHALL BE LEFT IN BROOM-CLEAN

CONDITION AT ALL TIMES. CONTRACTOR SHALL LOCATE AND

MAINTAIN A TRASH BIN AT THE SITE. SUCH BIN SHALL BE OF

ADEQUATE DIMENSION TO KEEP SITE CLEAN AT ALL TIMES. DUST

RESULTING FROM SALVAGE, DEMOLITION AND REMOVAL WORK

SHALL BE CONTROLLED TO PREVENT THE IMPOSITION OF A

NUISANCE OR HAZARDOUS CONDITION TO THE ADJOINING

PORTION OF THE PROJECT. THE USE OF WATER WILL NOT BE

PERMITTED WHEN SUCH USE WOULD RESULT IN HAZARDOUS, OR

OTHERWISE OBJECTIONABLE CONDITIONS.

28. CONTRACTOR SHALL PROVIDE PEDESTRIAN PROTECTION IN

ACCORDANCE WITH ALL APPLICABLE BUILDING CODES.

29. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO

ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL

TIMES.

30. CONTRACTOR SHALL PROVIDE REQUIRED PROTECTION INCLUDING,

BUT NOT LIMITED TO, SHORING, BRACING, AND ALL OTHER

SUPPORTS (INCLUDING ENGINEERING OF SYSTEMS) NECESSARY TO

MAINTAIN OVERALL STRUCTURAL INTEGRITY OF THE BUILDING. ALL

DEMOLITION AND CUTTING SHALL BE PERFORMED IN A MANNER

AND BY METHODS WHICH ENSURE AGAINST DAMAGE TO EXISTING

WORK.

31. INTERIOR WALL AND CEILING FINISHES FOR DINING, AND WAITING

AREAS SHALL NOT EXCEED FLAME SPREAD CLASSIFICATIONS

DICTATED BY ALL APPLICABLE BUILDING CODES.

32. NO STRUCTURAL MEMBERS SHALL BE CUT TO ACCEPT PIPES, VENTS,

DUCTS, OR OTHER PENETRATIONS, EXCEPT AS DETAILED OR

SPECIFIED HEREIN.

33. GYPSUM BOARD AND SUSPENDED CEILING SYSTEMS SHALL

CONFORM TO ALL LOCAL GOVERNING BUILDING CODES AND

ORDINANCES.

34. ALL GLASS AND GLAZING SHALL COMPLY WITH ALL APPLICABLE

BUILDING CODES AS WELL AS THE U.S. CONSUMER PRODUCT

SAFETY COMMISSION, SAFETY STANDARDS FOR ARCHITECTURAL

GLAZING MATERIALS (47 FR, 13516 TITLE NO. 16, CHAPTER 11, PART

1201).

35. CONTRACTOR SHALL ASSIST OWNER IN OBTAINING FINAL

APPROVAL OF LOCAL HEALTH DEPARTMENT AND THE TEMPORARY

AND FINAL CERTIFICATES OF OCCUPANCY.

36. CONTRACTOR SHALL BE RESPONSIBLE FOR, AND SHALL REMEDY,

REPAIR, OR REPLACE ANY FAULTY, IMPROPER OR INFERIOR

WORKMANSHIP OR MATERIALS AND ANY RELATED DAMAGE

CAUSED BY THESE WHICH SHALL APPEAR WITHIN ONE (1) YEAR

AFTER THE COMPLETION AND ACCEPTANCE OF THE WORK UNDER

THIS CONTRACT. REFER TO SPECIFICATIONS FOR WARRANTY

REQUIREMENTS IN EXCESS OF ONE (1) YEAR. IN ADDITION TO

EQUIPMENT WARRANTIES, FURNISH OWNER A WRITTEN GUARANTEE

AGAINST LATENT AND PATENT DEFECTS IN MATERIALS AND

WORKMANSHIP FOR ONE (1) YEAR. GUARANTEE SHALL INCLUDE

REPAIR, DAMAGE TO, OR REPLACEMENT OF, ANY PART OF

EQUIPMENT PROVIDED.

37. PIPES, CONDUITS, OR DUCTS EXCEEDING ONE THIRD OF THE SLAB

OR MEMBER THICKNESS SHALL NOT BE PLACED IN STRUCTURAL

CONCRETE UNLESS SPECIFICALLY DETAILED. REFER TO

MECHANICAL, ELECTRICAL, PLUMBING, AND STRUCTURAL

DRAWINGS FOR LOCATION OF SLEEVES AND OTHER ACCESSORIES.

38. ALL ELECTRICAL, MECHANICAL, AND PLUMBING WORK SHALL

CONFORM TO THE REQUIREMENTS OF ALL THE LEGALLY

CONSTITUTED AUTHORITIES HAVING JURISDICTION.

39. ALL EQUIPMENT ON THE FOOD SERVICE DRAWINGS IS TO BE

EXCLUDED FROM THE GENERAL CONTRACT UNLESS OTHERWISE

STATED. BACKING, ROUGH-INS, AND FINAL HOOK-UPS ARE A PART

OF THE GENERAL CONTRACT. ALL PLUMBING FIXTURE VACUUM

BREAKERS NECESSARY, PER LOCAL CODE REQUIREMENTS, ARE TO

BE SUPPLIED WITH KITCHEN EQUIPMENT. ELECTRICAL

CONNECTIONS AND DISCONNECTS NECESSARY TO MEET LOCAL

CODE REQUIREMENTS WILL BE SUPPLIED WITH KITCHEN EQUIPMENT

WITH FINAL HOOK-UPS ONLY BY CONTRACTOR.

40. CONTRACTOR SHALL PROVIDE BACKING FOR SUPPORT OF ALL

WALL, CEILING, AND PARTITION MOUNTED ITEMS SUCH AS TABLE

BRACKETS, LIGHT FIXTURES, ARTIFACTS, SHELVING, EQUIPMENT, AND

TELEVISIONS. COORDINATE LOCATIONS AND REQUIREMENTS WITH

THE PLUMBING, MECHANICAL, ELECTRICAL, AND FOOD SERVICE

DRAWINGS AS WELL AS INTERIOR DESIGN CONSULTANT AND

OWNER.

41. CONTRACTOR SHALL VERIFY LOCATIONS OF FOOD SERVICE

EQUIPMENT AND COORDINATE LOCATIONS OF FLOOR SINKS,

FLOOR DRAINS, TROUGH DRAINS, SLAB DEPRESSIONS, RAISED

CURBS, ELECTRICAL STUB-OUTS, PLUMBING STUB-OUTS, AND ALL

OTHER WORK UNDER THE SCOPE OF RESPONSIBILITIES RELATED TO

THIS EQUIPMENT. REFER TO THE FOOD SERVICE DRAWINGS FOR

ADDITIONAL INFORMATION.

42. PROVIDE ATTIC DRAFT STOPS AND VENTILATION IN

CONFORMANCE WITH ALL APPLICABLE BUILDING CODES.

43. ALL PAINT COLOR AND/OR MATERIAL TRANSITIONS ARE TO OCCUR

AT INSIDE CORNERS (UNLESS NOTED OTHERWISE).

44. COMPLETE SHOP DRAWINGS AND EQUIPMENT SUBMITTALS SHALL

BE PROVIDED TO THE ARCHITECT FOR REVIEW AND COMMENT

PRIOR TO FABRICATION OR ORDERING OF ANY EQUIPMENT,

FIXTURES, MATERIALS, OR ASSEMBLIES.

45. OWNER'S REPRESENTATIVE OR ARCHITECT WILL REVIEW AND

COMMENT ON ALL SHOP DRAWINGS AND SAMPLES FOR

CONFORMANCE WITH THE DESIGN INTENT OF THE PROJECT ONLY.

THE APPROVAL OF A SINGLE COMPONENT SHALL NOT INDICATE

THE APPROVAL OF AN ASSEMBLY IN WHICH THE ITEM FUNCTIONS.

46. ALL SHOP DRAWINGS AND SUBMITTALS SHALL BE ROUTED THROUGH

THE CONTRACTOR. NO DOCUMENTS SHALL BE SUBMITTED

DIRECTLY TO THE ARCHITECT, OR TO THE ARCHITECT'S

CONSULTANTS. SUBMIT ALL SHOP DRAWINGS IN THE FORM OF ONE

(1) 30" X 42" TRANSPARENCY (SEPIA) OF EACH SHEET. BLUELINES OR

BLACKLINES ARE NOT ACCEPTABLE. WHEN SHOP DRAWINGS

INVOLVE MANUFACTURER'S DATA OR MATERIAL LIST, SUBMIT A

MINIMUM OF FIVE (5) COPIES FOR REVIEW AND COMMENT.

47. EXTERIOR OPENINGS SHALL COMPLY WITH ALL SECURITY

REQUIREMENTS AS OUTLINED IN ALL LOCAL BUILDING CODES AND

ORDINANCES.

48. ACCURATE AS-BUILT DRAWINGS SHALL BE GENERATED BY

CONTRACTOR DURING CONSTRUCTION AND SUBMITTED TO

OWNER UPON COMPLETION OF FINAL PUNCH LIST, BUT PRIOR TO

REQUEST FOR FINAL PAYMENT. WITHIN TWO WEEKS AFTER C.O. IS

ACQUIRED.

49. FOUR (4) SETS OF EQUIPMENT OPERATING AND MAINTENANCE

MANUALS SHALL BE SUBMITTED TO THE OWNER UPON COMPLETION

OF PROJECT, BUT PRIOR TO REQUEST FOR FINAL PAYMENT. WITHIN

TWO WEEKS AFTER C.O. IS ACQUIRED.

50. CONTRACTOR SHALL NOT ALLOW ANY PERSON TO DESCEND INTO

ANY TRENCH OR HOLE, OR CREATE ANY SUCH EXCAVATIONS,

WITHOUT THE PRIOR APPROVAL OF BUILDING DEPARTMENT AS

WELL AS ALL OTHER AGENCIES HAVING JURISDICTION.

51. VERIFY FIRE EXTINGUISHER REQUIREMENTS AND LOCATIONS WITH

FIRE MARSHAL AND OWNER'S REPRESENTATIVE.

52. CONTRACTOR SHALL SEAL ALL GAPS, HOLES, AND CRACKS IN

BUILDING CONSTRUCTION AS REQUIRED TO CONTROL

INFILTRATION OF INSECTS.

53. CONTRACTOR SHALL INSTRUCT SUBCONTRACTORS TO CAREFULLY

REVIEW THE CONSTRUCTION DOCUMENTS IN THEIR ENTIRETY.

INFORMATION REGARDING COMPLETE WORK OF SPECIFIC TRADES

AND SUB-TRADES IS DISPERSED THROUGHOUT THE DRAWINGS AND

SPECIFICATIONS AND CANNOT BE DETERMINED BY REFERENCE TO

ANYTHING OTHER THAN COMPLETE SETS OF DOCUMENTS.

54. NOTHING IN THESE DOCUMENTS IS TO BE INTERPRETED AS

RELIEVING THE CONTRACTOR OF SOLE RESPONSIBILITY FOR THE

METHODS AND MEANS OF CONSTRUCTION, AS WELL AS SAFETY AT

THE JOB SITE.

55. THE LIFE SAFETY INSPECTOR WILL MAKE FINAL

DETERMINATION OF FIRE LANES BEFORE FINAL INSPECTION

IS MADE. SEE SITE PLAN FOR REQUIREMENTS.

CONTRACTOR

TBD

MONUMENT HALL CLOSETS

1102 ELM WALK

GRAND JUNCTION, CO

NOT FOR CONSTRUCTION

SCALE:

SHEET NO:

DATE:

2394 PATTERSON ROAD, SUITE 201

GRAND JUNCTION, CO 81505

126 ELK AVENUE, UNIT 1

CRESTED BUTTE, CO 81224

T: 970.712.5045

REVISION(S):

PROJECT NO:

SHEET NAME:

KRAAI DESIGN

ARCHITECTURE

T1.0

04/08/2025

M O

N U

M E N

T H

A

LL

C

LO

S E

TS

E

LM

W A

LK

G

R A

N D

J U

N C

TI

O

N C

O

REVIEW SET

TITLE SHEET

SHEET INDEX

SHEET NUMBER SHEET NAME

COVER

T1.0 TITLE SHEET

ARCHITECTURAL

A1.1 MAIN LEVEL PLAN, ELEVATIONS, SCHEDULES

# DATE COMMENTS

Sheets
A1.1 - MAIN LEVEL PLAN, ELEVATIONS, SCHEDULES
T1.0 - TITLE SHEET

File details come from the government source that posted it. Updated .