234042 Proposal Page Attachment 1.xlsx
XLSX spreadsheet 28 KB Posted
- Attached to
- Bid No. 234042 Underwater Services
- Solicitation number
- S-KS0043-00006715
- Issued by
- Marion County, Oregon
About this file
This document is a bid solicitation for Bid No. 234042 Underwater Services issued by the City of Salem, Oregon. The bid covers water finished water reservoirs and intake structures, as well as general underwater services and wastewater treatment plant services for the City of Salem and Marion County. The bid includes detailed information on 19 finished water reservoirs, 2 water intake structures, and various underwater services such as diver, ROV, cleaning, and disinfection. The bid requires pricing on all items, with the total bid for all sections. The bid does not provide a specific response or due date.
The pricing terms require unit prices and lump sum figures for the various services. There is no mention of any set asides, incumbents, or funding sources. The bid appears to be an open solicitation for underwater services to maintain and inspect the water infrastructure for the City of Salem and Marion County.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 234042 Technical Specifications~1.pdf | ||
| ATT B Plans~6.pdf | ||
| 234042 Technical Specifications.pdf | ||
| 234042 Tabulation Sheet.pdf | ||
| 234042 Bid Manual.pdf | ||
| 234042 Notice Intent to Award.pdf | ||
| Zoom Bid Opening Instruction s5.16.23.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BID DOCUMENT
Section A City of Salem Water Finished Water Reservoirs
| Reservoir | Date Built | Location | Capacity (mg) | Reservoir Type | Dimensions | Floor Surface Area (ft2) | Special Considerations | Inspection Cost - Divers ( 1 ) | Inspection Cost - ROV ( 2 ) | Cleaning Cost ( 3 ) 1 | Disinfection Cost ( 4 ) |
| Fairmount | 1936 | Salem, OR | 10 | Concrete | 180' x 360' x 22' Height | 64,800 | $ | $ | $ | $ | |
| Candalaria | 1940 | Salem, OR | 0.5 | Concrete | 122' x 48' x 15' Height | 5,856 | Online Dive Only | $ | $ | $ | $ |
| Kurth | 1954 | Salem, OR | 1 | Steel | 76' Diameter x 47' Height | 4,536 | Above Ground | $ | $ | $ | $ |
| College | 1957 | Salem, OR | 0.5 | Steel | 44' Diameter x 44' Height | 1,520 | Above Ground- Online Dive Only | $ | $ | $ | $ |
| Seeger | 1960 | Salem, OR | 1.5 | Steel | 76' Diameter x 47' Height | 4,536 | Above Ground | $ | $ | $ | $ |
| Eola #2 | 1962 | Salem, OR | 0.175 | Concrete | 52' x 32' x 15' Height | 1,664 | Online Dive Only | $ | $ | $ | $ |
| Glen Creek | 1972 | Salem, OR | 2 | Concrete | 167' x 93' x 22' Height | 15,531 | No local sewer | $ | $ | $ | $ |
| Mountain View | 1972 | Salem, OR | 10 | Concrete | 290' Diameter x 20' Height | 66,051 | Online Dive Only | $ | $ | $ | $ |
| Mader | 1974 | Salem, OR | 1.5 | Steel | 65' Diameter x 48' Height | 3,318 | Above Ground | $ | $ | $ | $ |
| Skyline | 1978 | Salem, OR | 1.25 | Concrete | 92' x 92' x 20' Height | 8,464 | No local sewer | $ | $ | $ | $ |
| Chacarun | 1980 | Salem, OR | 2 | Concrete | 130' Diameter x 22' Height | 13,273 | No local sewer | $ | $ | $ | $ |
| Croisan Mountain | 1991 | Salem, OR | 0.85 | Concrete | 85' Diameter x 20' Height | 5,674 | Online Dive Only | $ | $ | $ | $ |
| Eola #1B | 2001 | Salem, OR | 0.8 | Concrete | 97' Diameter x 16' Height | 7,389 | Online Dive Only | $ | $ | $ | $ |
| Grice Hill | 2002 | Salem, OR | 2.2 | Concrete | 70' Diameter x 21.5 ' Height | 3,848 | $ | $ | $ | $ | |
| Lone Oak | 2003 | Salem, OR | 5.6 | Concrete | 196' Diameter x 21' Height | 30,171 | $ | $ | $ | $ | |
| Franzen - East Cell | 2004 (rebuilt) | Turner, OR | 42 | Earthen | 900' x 300' x 30' Height | 270,000 | $ | $ | $ | $ | |
| Franzen - West Cell | 2004 (rebuilt) | Turner, OR | 47 | Earthen | 1100' x 300' x 30' Height | 330,000 | $ | $ | $ | $ | |
| Mill Creek | 2014 | Salem, OR | 2.2 | Concrete | 140' Diameter x 20' Height | 15,393 | Above Ground- Online Dive Only | $ | $ | $ | $ |
| Champion Hill | 2006 | Salem, OR | 2.2 | Concrete | 140' Diameter x 20' Height | 15,393 | Above Ground | $ | $ | $ | $ |
| SUB - TOTALS | $ | $ | $ | $ |
| TOTAL COST FOR COLUMN 1+2+3+4 (ALL ITEMS MUST BE BID) | $ | ||||||||
| Section B | City of Salem Water Intake Structures | ||||||||
| Structure | Date Built | Location | Material | Dimensions | Special Considerations | Inspection Cost | |||
| Geren Island Middle Intake | 1998 | Stayton, OR | Steel/Concrete | 120' x 6' | Fish Screens | $ | |||
| Geren Island Upper Intake | 2009 | Stayton, OR | Steel/Concrete | 6' x 6' | Fish Screens | $ | |||
| TOTAL COST FOR WATER INSTAKE STRUCTURES (ALL ITEMS MUST BE BID) | $ |
1 Cleaning cost includes up to 1" sediment removal. Depth of sediment to be determined by average of four measurements in different locations on the floor.
| Section C | City of Salem Water General Underwater Services | ||||
| Item | Quantity | Unit Of Measure | Unit Price or Lump Sum Figures | Total Amount- Quantity x Unit Price | |
| Mobilization | All Req’d | Lump Sum | $ | $ | |
| Underwater diver | 80 | Hours | $ | $ | |
| Topside crew | 80 | Hours | $ | $ | |
| ROV Vehicle | 40 | Hours | $ | $ | |
| TOTAL COST FOR WATER GENERAL SERVICES (ALL ITEMS MUST BE BID) | $ |
| Section D | City of Salem Wastewater Treatment Plant Services | ||||
| Item | Quantity | Unit Of Measure | Unit Price or Lump Sum Figures | Total Amount- Quantity x Unit Price | |
| Mobilization for wastewater treatment plant work | All Req’d | Lump Sum | $ | $ | |
| Internal inspection of 54-inch wastewater treatment plant outfall pipe with ROV or diver | 1 | Each | $ | $ | |
| Cleaning and inspection of wastewater treatment plant outfall – in water work | All Req’d | Lump Sum | $ | $ | |
| Repair of broken diffuser check valves on wastewater treatment plant outfall | 3 | Day | $ | $ | |
| Cleaning and removal of sediment and debris from the inside of the 54-inch wastewater treatment plant outfall pipe | 200 | ft3 | $ | $ | |
| TOTAL COST FOR WASTEWATER TREATMENT (ALL ITEMS MUST BE BID) | $ |
TOTAL BID FOR SECTIONS A + B + C + D (ALL ITEMS MUST BE BID) $
Sheet1 City of Salem Water Finished Water Reservoirs
| Reservoir | Date Built | Location | Capacity (mg) | Reservoir Type | Dimensions | Floor Surface Area (ft2) | Special Considerations | Inspection Cost - Divers | Inspection Cost - ROV | Cleaning Cost1 | Disinfection Cost |
| Fairmount | 1936 | Salem, OR | 10 | Concrete | 180' x 360' x 22' Height | 64,800 | |||||
| Candalaria | 1940 | Salem, OR | 0.5 | Concrete | 122' x 48' x 15' Height | 5,856 | Online Dive Only | ||||
| Kurth | 1954 | Salem, OR | 1 | Steel | 76' Diameter x 47' Height | 4,536 | Above Ground | ||||
| College | 1957 | Salem, OR | 0.5 | Steel | 44' Diameter x 44' Height | 1,520 | Above Ground- Online Dive Only | ||||
| Seeger | 1960 | Salem, OR | 1.5 | Steel | 76' Diameter x 47' Height | 4,536 | Above Ground | ||||
| Eola #2 | 1962 | Salem, OR | 0.175 | Concrete | 52' x 32' x 15' Height | 1,664 | Online Dive Only | ||||
| Glen Creek | 1972 | Salem, OR | 2 | Concrete | 167' x 93' x 22' Height | 15,531 | No local sewer | ||||
| Mountain View | 1972 | Salem, OR | 10 | Concrete | 290' Diameter x 20' Height | 66,051 | |||||
| Mader | 1974 | Salem, OR | 1.5 | Steel | 65' Diameter x 48' Height | 3,318 | Above Ground | ||||
| Skyline | 1978 | Salem, OR | 1.25 | Concrete | 92' x 92' x 20' Height | 8,464 | No local sewer | ||||
| Chacarun | 1980 | Salem, OR | 2 | Concrete | 130' Diameter x 22' Height | 13,273 | No local sewer | ||||
| Croisan Mountain | 1991 | Salem, OR | 0.85 | Concrete | 85' Diameter x 20' Height | 5,674 | Online Dive Only | ||||
| Eola #1B | 2001 | Salem, OR | 0.8 | Concrete | 97' Diameter x 16' Height | 7,389 | Online Dive Only | ||||
| Grice Hill | 2002 | Salem, OR | 2.2 | Concrete | 70' Diameter x 21.5 ' Height | 3,848 | |||||
| Lone Oak | 2003 | Salem, OR | 5.6 | Concrete | 196' Diameter x 21' Height | 30,171 | |||||
| Franzen - East Cell | 2004 (rebuilt) | Turner, OR | 42 | Earthen | 900' x 300' x 30' Height | 270,000 | |||||
| Franzen - West Cell | 2004 (rebuilt) | Turner, OR | 47 | Earthen | 1100' x 300' x 30' Height | 330,000 | |||||
| Mill Creek | 2014 | Salem, OR | 2.2 | Concrete | 140' Diameter x 20' Height | 15,393 | Above Ground- Online Dive Only | ||||
| Champion Hill | 2006 | Salem, OR | 2.2 | Concrete | 140' Diameter x 20' Height | 15,393 | Above Ground |
City of Salem Water Intake Structures
| Structure | Date Built | Location | Material | Dimensions | Special Considerations | Inspection Cost |
| Geren Island Middle Intake | 1998 | Stayton, OR | Steel/Concrete | 120' x 6' | Fish Screens | |
| Geren Island Upper Intake | 2009 | Stayton, OR | Steel/Concrete | 6' x 6' | Fish Screens |
1 Cleaning cost includes up to 1" sediment removal. Depth of sediment to be determined by average of four measurements in different locations on the floor.
Sheet2 City of Salem Water Finished Water Reservoirs
| Reservoir | Capacity (MG) | Dimensions | Floor Surface Area (ft2) | Inspection Cost - Divers | Inspection Cost - ROV | Cleaning Cost1 | Disinfection Cost |
| Fairmount | 10 | 180' x 360' x 22' H | 64,800 | ||||
| Candalaria | 0.5 | 122' x 48' x 15' H | 5,856 | ||||
| Kurth | 1 | 76' Dia x 47' H | 4,536 | ||||
| College | 0.5 | 44' Dia x 44' H | 1,520 | ||||
| Seeger | 1.5 | 76' Dia x 47' H | 4,536 | ||||
| Eola #2 | 0.175 | 52' x 32' x 15' H | 1,664 | ||||
| Glen Creek | 2 | 167' x 93' x 22' H | 15,531 | ||||
| Mountain View | 10 | 290' Dia x 20' H | 66,051 | ||||
| Mader | 1.5 | 65' Dia x 48' H | 3,318 | ||||
| Skyline | 1.25 | 92' x 92' x 20' H | 8,464 | ||||
| Chacarun | 2 | 130' Dia x 22' H | 13,273 | ||||
| Croisan Mountain | 0.85 | 85' Dia x 20' H | 5,674 | ||||
| Eola #1B | 0.8 | 97' Dia x 16' H | 7,389 | ||||
| Grice Hill | 2.2 | 70' Dia x 21.5 ' H | 3,848 | ||||
| Lone Oak | 5.6 | 196' Dia x 21' H | 30,171 | ||||
| Franzen - East Cell | 42 | 900' x 300' x 30' H | 270,000 | ||||
| Franzen - West Cell | 47 | 1100' x 300' x 30' H | 330,000 | ||||
| Mill Creek | 2.2 | 140' Dia x 20' H | 15,393 | ||||
| Champion Hill | 2.2 | 140' Dia x 20' H | 15,393 |
City of Salem Water Intake Structures
| Structure | Material | Special Considerations | Inspection Cost |
| Geren Island Middle Intake | Steel/Concrete | Fish Screens | |
| Geren Island Upper Intake | Steel/Concrete | Fish Screens |
1 Cleaning cost includes up to 1" sediment removal. Depth of sediment to be determined by average of four measurements in different locations on the floor.
File details come from the government source that posted it. Updated .