This document includes a federal construction project specification and solicitation. The specification outlines requirements for air outlets and inlets, including roof curbs, diffusers, registers, grilles, and intake/exhaust ventilators. Material, performance, and finish standards are specified for return/exhaust registers and grilles. The related solicitation is for construction of a new parking garage at the Wilkes-Barre VA Medical Center in Pennsylvania, with a project magnitude between $10 million to $20 million. As a set-aside for verified service-disabled veteran-owned small businesses, the solicitation will use a tiered evaluation process including large businesses. Offerors must price in whole dollars and the contractor will be responsible for correct worker classification and wage/hour law compliance. The closing date is not provided.
View the file
Other files for this federal contract opportunity
Show all 50
Y1LZ--693-222 | Parking Structure Solicitation Amendment 2 has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Parking Garage Project Number 693-222 Department of Veterans Affairs Wilkes-Barre, Pennsylvania
233700 - 1
SECTION 23 37 00 - AIR OUTLETS AND INLETS
PART 1 - GENERAL
1.1 DESCRIPTION
A. Roof Curbs
B. Air Outlets and Inlets: Diffusers, Registers, and Grilles.
1.2 RELATED WORK
A. Testing and Balancing of Air Flows: Section 23 05 93, TESTING, ADJUSTING, AND
BALANCING FOR HVAC.
1.3 QUALITY ASSURANCE
A. Refer to article, QUALITY ASSURANCE, in Section 23 05 11, COMMON WORK
RESULTS FOR HVAC.
B. Fire Safety Code: Comply with NFPA 90A.
1.4 SUBMITTALS
A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, and SAMPLES.
B. Manufacturer's Literature and Data:
1. Air intake/exhaust hoods.
2. Diffusers, registers, grilles and accessories.
C. Coordination Drawings: Refer to article, SUBMITTALS, in Section 23 05 11, COMMON
WORK RESULTS FOR HVAC.
1.5 APPLICABLE PUBLICATIONS
A. The publications listed below form a part of this specification to the extent referenced.
The publications are referenced in the text by the basic designation only.
B. Air Diffusion Council Test Code:
1062 GRD-84........................Certification, Rating, and Test Manual 4th Edition
C. American Society of Civil Engineers (ASCE):
Wilkes-Barre, Pennsylvania
233700 - 2
ASCE7-05 .............................Minimum Design Loads for Buildings and Other Structures
D. American Society for Testing and Materials (ASTM):
A167-99 (2004) .....................Standard Specification for Stainless and Heat-Resisting
Chromium-Nickel Steel Plate, Sheet and Strip
B209-07 ................................Standard Specification for Aluminum and Aluminum-Alloy
Sheet and Plate
E. National Fire Protection Association (NFPA):
90A-09 ..................................Standard for the Installation of Air Conditioning and
Ventilating Systems
F. Underwriters Laboratories, Inc. (UL):
181-08...................................UL Standard for Safety Factory-Made Air Ducts and
Connectors
PART 2 - PRODUCTS
2.1 GRAVITY INTAKE/EXHAUST VENTILATORS (ROOF MOUNTED)
A. Aluminum, ASTM B209, louvered, spun, or fabricated using panel sections with roll-formed edges, 13 mm (1/2 inch) mesh aluminum welded wire bird screen, with gravity or motorized dampers where shown, accessible interior, designed for wind velocity specified in Paragraph 3.3.
1. Spun Intake/Exhaust Ventilators: Spun aluminum structural components shall be constructed of minimum 1.3 mm (16 Gauge) marine alloy aluminum, bolted to a rigid aluminum support structure. The aluminum base shall have continuously welded curb cap corners for maximum leak protection. The spun aluminum baffle shall have a rolled bead for added strength.
2. Louvered Intake/Exhaust Hoods: Louvered hood constructed from 0.081 Gauge extruded aluminum tiers welded to a minimum 3.3 mm (8 Gauge) aluminum support structure. The aluminum hood shall be constructed of a minimum 0.064 marine alloy aluminum and provided with a layer of anti-condensate coating. The aluminum base shall have continuously welded curb cap corners for maximum leak protection.
3. Low Silhouette Intake/Exhaust Ventilator: The unit shall be of bolted and welded construction utilizing corrosion resistant fasteners. The aluminum hood shall be constructed of minimum 1.60 mm (14 Gauge) marine alloy aluminum, bolted to a
Wilkes-Barre, Pennsylvania
233700 - 3 minimum 3.25 mm (8 Gauge) aluminum support structure. The aluminum base shall have continuously welded curb cap corners for maximum leak protection. Birdscreen constructed of 13 mm (1/2 inch) mesh shall be mounted across the relief opening.
B. See ventilator schedule on the drawings. Sizes shown on the drawings designate throat size. Area of ventilator perimeter opening shall be not less than the throat area.
C. Dampers for Gravity Ventilators without Duct Connection: Construct damper of the same material as the ventilator and of the design to completely close opening or remain wide open. Hold damper in closed position by a brass chain and catch. Extend chains 300 mm (12 inches) below and engage catch when damper is closed.
D. Provide Roof Curb by unit manufacturer. Refer to Section 23 05 11, COMMON WORK
RESULTS FOR HVAC for additional requirements.
2.2 EQUIPMENT SUPPORTS
Refer to Section 21 05 11, COMMON WORK RESULTS FOR FIRE SUPPRESSION, Section 22 05 11, COMMON WORK RESULTS FOR PLUMBING, and Section 23 05 11, COMMON WORK RESULTS FOR HVAC.
2.3 AIR OUTLETS AND INLETS
A. Materials:
1. Steel or aluminum. Use aluminum air outlets and inlets for facilities located in high-humidity areas. Exhaust air registers located in combination toilets and shower stalls shall be constructed from aluminum. Provide manufacturer's standard gasket.
2. Exposed Fastenings: The same material as the respective inlet or outlet. Fasteners for aluminum may be stainless steel.
3. Contractor shall review all ceiling drawings and details and provide all ceiling mounted devices with appropriate dimensions and trim for the specific locations.
B. Performance Test Data: In accordance with Air Diffusion Council Code 1062GRD. Refer to Section 23 05 41, NOISE AND VIBRATION CONTROL FOR HVAC PIPING AND
EQUIPMENT for NC criteria.
C. Return and Exhaust Registers and Grilles: Provide opposed blade damper without removable key operator for registers.
Wilkes-Barre, Pennsylvania
233700 - 4
1. Finish: Off-white baked enamel for ceiling mounted units. Wall units shall have a prime coat for field painting, or shall be extruded aluminum with manufacturer's standard aluminum finish.
2. Standard Type: Fixed horizontal face bars set at 30 to 45 degrees, approximately 30 mm (1-1/4 inch) margin.
3. Perforated Face Type: To match supply units.
4. Grid Core Type: 13 mm by 13 mm (1/2 inch by 1/2 inch) core with 30 mm (1-1/4 inch) margin.
5. Linear Type: To match supply units.
6. Door Grilles: Are furnished with the doors.
7. Egg Crate Grilles: Aluminum or Painted Steel 1/2 by 1/2 by 1/2 inch grid providing
90% free area.
a. Heavy extruded aluminum frame shall have countersunk screw mounting.
Unless otherwise indicated, register blades and frame shall have factory applied white finish.
b. Grille shall be suitable for duct or surface mounting as indicated on drawings. All necessary appurtenances shall be provided to allow for mounting.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Comply with provisions of Section 23 05 11, COMMON WORK RESULTS FOR HVAC, particularly regarding coordination with other trades and work in existing buildings.
B. Protection and Cleaning: Protect equipment and materials against physical damage.
Place equipment in first class operating condition, or return to source of supply for repair or replacement, as determined by Resident Engineer. Protect equipment during construction against entry of foreign matter to the inside and clean both inside and outside before operation and painting.
3.3 TESTING, ADJUSTING AND BALANCING (TAB)
Refer to Section 23 05 93, TESTING, ADJUSTING, AND BALANCING FOR HVAC.
Wilkes-Barre, Pennsylvania
233700 - 5
3.4 OPERATING AND PERFORMANCE TESTS
Refer to Section 23 05 11, COMMON WORK RESULTS FOR HVAC AND STEAM
GENERATION
- - - END OF SECTION - - -
| PART 1 � GENERAL |
| 1.1 DESCRIPTION |
| 1.2 RELATED WORK |
| 1.3 QUALITY ASSURANCE |
| 1.4 SUBMITTALS |
| 1.5 APPLICABLE PUBLICATIONS |
| PART 2 � PRODUCTS |
| 2.1 Gravity INTAKE/EXHAUST Ventilators (ROOF MOUNTED) |
| 2.2 EQUIPMENT SUPPORTS |
| 2.3 AIR OUTLETS AND INLETS |
| part 3 - execution |
| 3.3 testing, adjusting and balancing (tab) |
| 3.4 operating and performance tests |
File details come from the government source that posted it. Updated .