23352 MuskCF Greenhouse-Drwgs-Plumb.pdf

PDF 4 MB Posted

Attached to
472/23352. HJD; Muskegon CF - New Educational Greenhouse
Solicitation number
RFQ - 171 - 240000000403
Issued by
Muskegon County, Michigan

About this file

This document contains information related to a state and local contract opportunity for a Muskegon Correctional Facility Greenhouse project in Michigan. The project involves the demolition and installation of new domestic cold water, steam, and steam condensate piping, as well as the installation of new sanitary, ventilation, and plumbing systems for a new greenhouse facility. Key details include the requirement for a ground penetrating radar survey prior to construction, the need to slope the new steam condensate and steam piping, and the requirement to install the new direct buried piping at a minimum depth of 42 inches below grade. The bid attachments must be uploaded to SIGMA VSS, and if bidders experience any issues, they are instructed to contact the SIGMA Help Desk or the Office of Design and Construction.

The contract opportunity is for the state of Michigan, Department of Technology, Management and Budget, State Facilities Administration, Design and Construction Division. The project is located in Muskegon County, Michigan. Bids are due by 2:00 pm on the specified deadline date. Interested bidders may be asked to email their proposals, which will be handled on a case-by-case basis. No other pricing or set aside information is provided in the document.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

X-CW

X-CW

X-CW

X-CW, X-SC,

& X-STM UP

1 2 3

X-CWX-STMX-SC

X-STM

X-STM

X-STM

X-SC

X-SC

X-SC

2 3

1 2 3

1 2 3

2 3

X-GREENHOUSE

X-BUILDING

DEMOLITION NOTES

DISCONNECT, REMOVE, & DEMO EXISTING BURIED

DOMESTIC COLD WATER PIPING, VALVES, FITTINGS,

AND ALL ASSOCIATED ACCESSORIES IN THEIR

ENTIRETY. CONTRACTOR TO DEMOLISH DOMESTIC

COLD WATER MAIN BACK TO MAIN IN EXISTING

BUILDING BASEMENT AND CAP.

DISCONNECT, REMOVE, AND DEMO EXISTING

BURIED STEAM CONDENSATE PIPING, VALVES,

FITTINGS, AND ALL ASSOCIATED ACCESSORIES IN

THEIR ENTIRETY. CONTRACTOR TO DEMOLISH

STEAM CONDENSATE PIPING BACK TO MAIN IN

EXISTING BUILDING BASEMENT AND CAP.

DISCONNECT, REMOVE, AND DEMO EXISTING

BURIED STEAM PIPING, VALVES, FITTINGS, AND ALL

ASSOCIATED ACCESSORIES IN THEIR ENTIRETY.

CONTRACTOR TO DEMOLISH STEAM PIPING BACK

TO MAIN IN EXISTING BUILDING BASEMENT AND

CAP.

EXISTING BELOW GRADE EXTERIOR WALL

PENETRATIONS TO BE MODIFIED AS REQUIRED TO

BE REUSED FOR NEW PIPING SHOWN ON NEW

DRAWINGS.

GENERAL DEMOLITION NOTES

1. CONTRACTOR TO PROVIDE GROUND PENETRATING RADAR SURVEY PRIOR

TO CONSTRUCTION TO VERIFY LOCATIONS OF ALL EXISTING UNDERGROUND

UTILITIES IN THE AREA OF EXISTING DIRECT BURIED PIPING. ALL EXCAVATION

IS TO BE HYDROVAC-EXCAVATION.

2. CONTRACTOR TO BACKFILL AND RE-GRADE ALL GREEN AREAS AFFECTED BY

CONSTRUCTION TO MATCH EXISTING AFTER ALL DEMOLITION/NEW WORK IS

COMPLETE.

P e t t i t t Y a s t e

S t r a u b

200S

LAWSON,C MICHIGAN

UITE

48017-1311

F A X248-658-7781

248-658-7777 P H O N E

C850 NORTH ROOKS ROAD

MUSKEGON CORRECTIONAL

FACILITY

GREENHOUSE

M A

T R

I X

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T A

N D

B U

D G

E T

S T

A T

E O

F M

IC

H

IG

A

N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

MP2

BELOW GRADE -

PARTIAL SITE PLAN -

MECHANICAL/PLUMBING

DEMOLITION

N

BELOW GRADE - PARTIAL SITE PLAN -

MECHANICAL/PLUMBING DEMOLITION

SCALE: 1/8" = 1'-0"

0 1 5 10 20

CW

CW

CW

CW

1" CW, 1-1/2" STM,

& 1" SC UP

SC

SC

SC

STM

1" CW , 1-1/2" STM,

& 1" SC (BURIED)

2 3

1" CW , 1-1/2" STM,

& 1" SC (BURIED)

1 2 3

SC

STM

STM

STM

2 3

1" CW , 1-1/2" STM,

& 1" SC (BURIED)

1 2 3

1" CW , 1-1/2" STM,

& 1" SC (BURIED)

1 2 3

1" CW , 1-1/2" STM,

& 1" SC (BURIED)

1 2 3

STM

SC

CW

X-BUILDING

SLOPE

SLOPE

SLOPE

SLOPE

SLOPE

SLOPE

PIPE

ANCHOR

(TYP.)

PIPE ANCHOR

(TYP.)

2' x 2' x 4' WIDE CONCRETE

BLOCK ENCOMPASSING

PIPING ANCHORS

2' x 2' x 4' WIDE CONCRETE

BLOCK ENCOMPASSING

PIPING ANCHORS

5'-0"

10'-0"

MECHANICAL/PLUMBING KEY NOTES

INSTALL NEW DIRECT BURIED DOMESTIC COLD WATER PIPING, VALVES, FITTINGS, AND ALL

ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS IN

THE LOCATION SHOWN. CONNECT NEW DOMESTIC COLD WATER PIPING TO EXISTING COLD

WATER PIPING IN EXISTING BUILDING BASEMENT. MODIFY EXISTING PIPING AS REQUIRED

FOR NEW CONNECTION.

INSTALL NEW DIRECT BURIED STEAM CONDENSATE PIPING, VALVES, FITTINGS, AND ALL

ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS IN

THE LOCATION SHOWN. CONNECT NEW STEAM CONDENSATE PIPING TO EXISTING STEAM

CONDENSATE PIPING IN EXISTING BUILDING BASEMENT. MODIFY EXISTING PIPING AS

REQUIRED FOR NEW CONNECTION.

INSTALL NEW DIRECT BURIED STEAM PIPING, VALVES, FITTINGS, AND ALL ASSOCIATED

ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS IN THE LOCATION

SHOWN. CONNECT NEW STEAM PIPING TO EXISTING STEAM PIPING IN EXISTING BUILDING

BASEMENT. MODIFY EXISTING PIPING AS REQUIRED FOR NEW CONNECTION.

ROUTE NEW DOMESTIC COLD WATER PIPING, STEAM PIPING, AND STEAM CONDENSATE

PIPING THOUGHT EXISTING BELOW GRADE EXTERIOR WALL PENETRATIONS. MODIFY

PENETRATIONS AS REQUIRED FOR NEW PIPING. PATCH EXISTING BELOW GRADE WALL

PENETRATIONS TO MATCH EXISTING AND SEAL WATER TIGHT ONCE NEW PIPING HAS BEEN

INSTALLED.

WELD NEW PIPE ANCHORS TO NEW STEAM AND STEAM CONDENSATE PIPING IN THE

LOCATION SHOWN. POUR NEW 2' TALL x 2' DEEP x 4' WIDE CONCRETE SLAB ENCOMPASSING

THE NEW DIRECT BURIED PIPING HAVING THE NEW PIPE ANCHORS CENTERED IN THE NEW

CONCRETE SLAB. CONCRETE SLAB IS TO BE COMPLETELY BURIED.

CONTRACTOR TO INSTALL EXPANSION LOOP AND ALL ASSOCIATED ACCESSORIES AS SHOWN

IN THE MIDDLE OFF THE NEW PIPING RUN. CONTRACTOR TO DIMENSION THE EXACT

LOCATION OF EXPANSION LOOP AND DOCUMENT THE LOCATON ON THE AS-BUILT DRAWINGS.

GENERAL MECHANICAL/PLUMBING NOTES

1. CONTRACTOR TO PROVIDE GROUND PENETRATING RADAR SURVEY PRIOR TO CONSTRUCTION TO VERIFY

LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES IN THE AREA OF EXISTING DIRECT BURIED PIPING.

ALL EXCAVATION IS TO BE HYDROVAC-EXCAVATION.

2. AFTER NEW DIRECT BURIED PIPING IS INSTALLED, CONTRACTOR TO PATCH ALL CONCRETE/ASPHALT AS

REQUIRED REQUIRED TO BE FLUSH AND MATCH EXISTING.

3. AFTER NEW DIRECT BURIED PIPING IS INSTALLED, CONTRACTOR TO RE-GRADE AND SEED ALL GREEN

AREAS AFFECTED BY CONSTRUCTION TO MATCH EXISTING.

4. SLOPE NEW STEAM CONDENSATE PIPING AWAY FROM THE NEW GREENHOUSE AND TOWARDS THE

EXISTING BUILDING.

5. SLOPE NEW STEAM PIPING AWAY FROM NEW GREENHOUSE AND TOWARDS THE EXISTING BUILDING.

6. ALL NEW DIRECT BURIED PIPING TO BE INSTALLED WITH TRACER WIRE.

7. ALL NEW DIRECT BURIED PIPING TO BE INSTALLED AT A MINIMUM DEPTH OF 42" FROM GRADE TO THE TOP

OF THE NEW PIPING.

SEEDING SCHEDULE

CONTRACTOR TO SUPPLY 6" OF TOPSOIL OVER ALL

DISTURBED AREAS. SEED ALL DISTURBED AREAS

WITH THE FOLLOWING SEED MIX:

40% KENTUCKY BLUEGRASS

25% CREEPING FESCUE

20% PERENNIAL RYEGRASS

15% CHEWING FESCUE

APPLY AT A RATE OF 8 LBS PER 1,000 SQUARE FEET

OR 350 LBS PER ACRE.

1 DIRECT BURIED PIPING DETAIL

SCALE: NTS

GENERAL NOTES:

1. ALL DIRECT BURIED PIPING TO BE INSTALLED

AT LEAST 42" BELOW GRADE FROM THE TOP OF

PIPE.

2. CONTRACTOR TO HYDROVAC-EXCAVATE ALL

LOCATIONS FOR NEW DIRECT BURIED PIPING.

CONTRACTOR TO PROVIDE SAND BASE LAYER

WHERE NEW DIRECT BURIED PIPING IS TO BE

INSTALLED. SAND BASE LAYER SHALL BE MDOT

CLASS II SAND COMPACTED TO 98% MAXIMUM.

SC

X-GRADEX-GRADE 42

" M

IN

STM

NEW SAND

BASE LAYER

X-SOIL

X-SOIL

X-SOIL

CW

NEW INFILL

P e t t i t t Y a s t e

S t r a u b

200S

LAWSON,C MICHIGAN

UITE

48017-1311

F A X248-658-7781

248-658-7777 P H O N E

C850 NORTH ROOKS ROAD

MUSKEGON CORRECTIONAL

FACILITY

GREENHOUSE

M A

T R

I X

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T A

N D

B U

D G

E T

S T

A T

E O

F M

IC

H

IG

A

N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

MP3

BELOW GRADE -

PARTIAL SITE PLAN -

MECHANICAL/PLUMBING

NEW

N

BELOW GRADE - PARTIAL SITE PLAN -

MECHANICAL/PLUMBING NEW

SCALE: 1/8" = 1'-0"

0 1 5 10 20

TD-1

CATCH

BASIN

TD-1

1" CW, 1" SC, & 1-1/2" STM

(BURIED, REFER TO PARTIAL

SITE PLAN FOR CONTINUATION)

1" CW, 1" SC, &

1-1/2" STM UP

SA

N

4"

4"

FCO

2" SAN UP

TO SK-1

4"

2" V UP

V

4" SAN TO DRYWELL

(REFER TO CIVIL FOR

CONTINUATION)

SAN

SAN SAN

4"

4"

CO (INSTALL WITHIN 5'

OF BUILDING)

FINISH FLOOR =100'-0"

I.E.=98'-6"

GENERAL MECHANICAL/ PLUMBING NOTES

1. INSTALL NEW BELOW GRADE SANITARY PIPING, VENT PIPING, AND ALL ASSOCIATED ACCESSORIES IN THE

LOCATION SHOWN.

MECHANICAL/ PLUMBING KEY NOTES

INSTALL NEW TRENCH DRAIN, CATCH BASIN, SANITARY PIPING, AND ALL ASSOCIATED

ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS IN THE LOCATION

SHOWN.

ROUTE NEW DOMESTIC COLD WATER PIPING, STEAM PIPING, AND STEAM CONDENSATE

PIPING UP THROUGH GREENHOUSE FLOOR IN THE LOCATION SHOWN.

50'-0 5/8" 24 5/8" 24'-0

1'-0"

ZURN MODEL #Z887-12-HD, 12"x24" CATCH BASIN w/P12-PS PERFORATED STAINLESS

STEEL GRATE

ZURN MODEL

P12-PS

PERFORATED

STAINLESS STEEL

GRATE.

24 5/8" 24'-0"

3" SAN

OUTLET

ZURN MODEL #FT

FOUL AIR TRAP

ZURN MODEL #Z887-12-HD,

12"x24" CATCH BASIN w/P12-PS PERFORATED

STAINLESS STEEL GRATE

NOTE: THIS CONNECTION MUST BE MADE

AT THE FACTORY

ZURN MODEL #Z-Z882 HIGH DENSITY

POLYETHYLENE WITH STEEL FRAME

TRENCH DRAIN SYSTEM

END CAP

PLAN VIEW

ELEVATION

1 TRENCH DRAIN WITH CATCH BASIN DETAIL

SCALE: NTS

FINISH FLOOR = 100'-0"

I.E. = 99'-11 1/2"

FINISH

FLOOR

1'-0" 12"

P e t t i t t Y a s t e

S t r a u b

200S

LAWSON,C MICHIGAN

UITE

48017-1311

F A X248-658-7781

248-658-7777 P H O N E

C850 NORTH ROOKS ROAD

MUSKEGON CORRECTIONAL

FACILITY

GREENHOUSE

M A

T R

I X

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T A

N D

B U

D G

E T

S T

A T

E O

F M

IC

H

IG

A

N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

MP4

BELOW 1ST FLOOR PLAN -

MECHANICAL/PLUMBING NEW

N BELOW 1ST FLOOR PLAN - MECHANICAL/PLUMBING NEW

SCALE: 1/4" = 1'-0"

0 1 5 10

UH-1

EF-2

L-1

UH-2

HAF-1 HAF-2

HAF-3 HAF-4

SC SC

STM

SC

STM

T

UH-1

T

UH-2

1" CW, 1" SC, &

1-1/2" STM DN

HB-1 DWH-1SK-12" V DN

SC

STM

SC

SC

ST

M

ST

M

1/2" HW, 2"

V, & 3/4" CW

EF-1M

PRV-1

1"

1"

3/4"

3/4"

2"

2"

1-1/4" 1-1/4" 1-1/4"

3 3

8GREENHOUSE

CONTROL PANEL

3/4"

1"

3/4"

1-1/4"

ST

M

2" V, 3" V

THRU WALL

AND DN

L-2

M

L-44

L-3 M

M

1/2" HW, 2"

V, & 1/2" CW

RV-1

(ON ROOF)

M M

9 9

10M

WH-1

1 STEAM COIL PIPING DETAIL

SCALE: NTS

FT

STEAM

COILVACUUM

BREAKER

STM

SC 6"

MI

N.

1/4"/FT TO

CONDENSATE

OUTLET.

PITCH COIL

SCALE POCKET

FLOAT & THERMOSTATIC STEAM TRAP

SHUTOFF VALVE (TYP.)

THERMOSTATIC AIR VENT

UNION (TYP.)

2-WAY, 2- POSITION CONTROL VALVE

STRAINER (TYP.)

DWH-1

2 DOMESTIC WATER HEATER DETAIL

SCALE: NTS

SHUT-OFF VALVE (TYP.)

1/2" CW

1/2" CW

DIELECTRIC UNION

(TYP.)

1/2" HW UP TO SK-1

1/2" HW

1-1/4" STM

3/4" SC

3 STEAM PRESSURE REDUCING VALVE DETAIL - NEW

SCALE: NTS

PRV-1

P

P

2" V THRU

SIDEWALL

STRAINER

PRESSURE

GAUGE (TYP.)

REDUCER (TYP.)

PRESSURE

RELIEF VALVE

1-1/2" STM

2" STM (10 PSI)

STEAM PRV NOTES:

1. ALLOW AT LEAST 10 PIPE DIAMETERS OF

STRAIGHT PIPE.

2. ALL PIPING VALVING ETC. ON HIGH PRESSURE

SIDE OF PRV'S SHALL BE WELDED OR FLANGED.

3. ALL ACCESSORY PIPING ON HIGH PRESSURE

SIDE OF PRV'S SHALL BE SCREWED AND BACK

WELDED.

4. PRV-1: 322# FOR INLET PRESSURE OF 40 PSI

AND OUTLET PRESSURE OF 10 PSI, SELF

OPERATED.

1-1/2" STM

N.C. SHUTOFF

VALVE (TYP.)

GENERAL MECHANICAL/PLUMBING NOTES

1. INSTALL NEW STEAM PIPING, VALVES, FITTINGS, AND ALL ASSOCIATED ACCESSORIES IN THE LOCATION

SHOWN.

2. INSTALL NEW STEAM CONDENSATE PIPING, VALVES, FITTINGS, AND ALL ASSOCIATED ACCESSORIES IN

THE LOCATION SHOWN.

3. INSTALL NEW DOMESTIC COLD WATER PIPING, DOMESTIC HOT WATER PIPING, VALVES, FITTINGS, AND

ALL ASSOCIATED ACCESSORIES IN THE LOCATION SHOWN.

4. INSTALL NEW VENT PIPING AND ALL ASSOCIATED ACCESSORIES IN THE LOCATION SHOWN.

MECHANICAL/PLUMBING KEY NOTES

INSTALL NEW WALL MOUNTED EXHAUST FANS, CONTROLS, CONTROL WIRING, AND ALL

ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.

CONNECT NEW EXHAUST FAN TO NEW GREENHOUSE CONTROL PANEL.

INSTALL NEW STEAM UNIT HEATER, THERMOSTAT, CONTROLS, CONTROL WIRING, STEAM

PIPING, CONDENSATE PIPING, VALVES, FITTINGS, AND ALL ASSOCIATED ACCESSORIES

PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. CONNECT NEW UNIT HEATER

TO NEW GREENHOUSE CONTROL PANEL.

INSTALL NEW RE-CIRCULATION FANS, CONTROLS, CONTROL WIRING, AND ALL

ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.

CONNECT NEW RE-CIRCULATION FANS TO NEW GREENHOUSE CONTROL PANEL.

INSTALL NEW LOUVER, DAMPER, DAMPER ACTUATOR, CONTROLS, CONTROL WIRING, AND

ALL ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION

INSTRUCTIONS. CONNECT NEW DAMPER ACTUATORS TO NEW GREENHOUSE CONTROL

PANEL.

INSTALL NEW INSTANTANEOUS DOMESTIC WATER HEATER, CONTROLS, PIPING, VALVES,

FITTINGS, AND ALL ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION

INSTRUCTIONS.

INSTALL NEW HOSE BIB, PIPING, VALVES, FITTINGS, AND ALL ASSOCIATED ACCESSORIES

PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.

INSTALL FLOOR MOUNTED SINK, FAUCET, PIPING, VALVES, FITTINGS, AND ALL

ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.

INSTALL NEW GREENHOUSE CONTROL PANEL, CONTROLS, CONTROL WIRING, AND ALL

ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.

COORDINATE FINAL INSTALLATION LOCATION WITH OWNER. CONNECT ALL GREENHOUSE

CONTROL PANEL TEMPERATURE ALARMS TO THE FACILITY'S STARNET 2.0 SYSTEM.

CONNECT TO SECURITY IT RACK WITH PURPLE CAT-6 CABLES(S) AS REQUIRED TO

CONNECT TO STARNET 2.0 SYSTEM. CONTRACTOR TO HIRE AND COORDINATE

CONNECTION TO SECURITY IT RACK WITH BRETT EMERSON FROM COMMTECH DESIGN

(PHONE 616-446-4545).

INSTALL NEW ROOF MOUNTED RIDGE VENT, NEW ACTUATOR(S), CONTROLS, CONTROL

WIRING, AND ALL ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION

INSTRUCTIONS. CONNECT NEW DAMPER ACTUATORS TO NEW GREENHOUSE CONTROL

PANEL.

EQUIPMENT PROVIDED BY GREENHOUSE MANUFACTURER.

INSTALL NEW WALL HYDRANT, PIPING, VALVES, FITTINGS, AND ALL ASSOCIATED

ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.

INSTALL NEW DOMESTIC WATER METER AND ALL ASSOCIATED ACCESSORIES IN THE

LOCATION SHOWN. CONTRACTOR TO COORDINATE WITH WITH DOMESTIC WATER

SERVICE PROVIDER FOR THE INSTALLATION OF NEW DOMESTIC WATER METER.

P e t t i t t Y a s t e

S t r a u b

200S

LAWSON,C MICHIGAN

UITE

48017-1311

F A X248-658-7781

248-658-7777 P H O N E

C850 NORTH ROOKS ROAD

MUSKEGON CORRECTIONAL

FACILITY

GREENHOUSE

M A

T R

I X

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T A

N D

B U

D G

E T

S T

A T

E O

F M

IC

H

IG

A

N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

MP5

1ST FLOOR PLAN -

MECHANICAL/PLUMBING NEW

N 1ST FLOOR PLAN - MECHANICAL/PLUMBING NEW

SCALE: 1/4" = 1'-0"

0 1 5 10

GREENHOUSE MANUFACTURER PROVIDEDMECHANICAL CONTRACTOR PROVIDED

P e t t i t t Y a s t e

S t r a u b

200S

LAWSON,C MICHIGAN

UITE

48017-1311

F A X248-658-7781

248-658-7777 P H O N E

C850 NORTH ROOKS ROAD

MUSKEGON CORRECTIONAL

FACILITY

GREENHOUSE

M A

T R

I X

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T A

N D

B U

D G

E T

S T

A T

E O

F M

IC

H

IG

A

N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

MP6

MECHANICAL/PLUMBING

SCHEDULES

Sheets and Views
MP1-2339900-MP1
MP2-2339900-MP2
MP3-2339900-MP3
MP4-2339900-MP4
MP5-2339900-MP5
MP6-2339900-MP6

File details come from the government source that posted it. Updated .