2330 Old Chesterfield Rd Lead Report.pdf
PDF 2 MB Posted
- Solicitation number
- 2025-02-028
- Issued by
- Horry County, Lugoff CDP, South Carolina
About this file
This document is a Lead-Based Paint Inspection Report prepared by Asbestos Inspections, LLC for Horry County Government, specifically for a single-family home located at 2330 Old Chesterfield Road in Longs, South Carolina. The inspection was conducted on January 10, 2025, with the report finalized on January 23, 2025, in preparation for the property's scheduled demolition. The assessment was performed in accordance with Department of Housing and Urban Development (HUD), Environmental Protection Agency (EPA), and Occupational Safety and Health Administration (OSHA) guidelines, with the primary purpose of identifying lead-based paint on building components prior to demolition.
The inspection revealed lead concentrations exceeding regulatory thresholds on two specific building components: black exterior wood window frames and black wood columns on the front porch. The approximately 786 square foot single-family home features a metal roof, vinyl siding, wood-framed windows, and mostly unpainted wood walls and ceilings, with select painted wood walls and vinyl floor coverings. The laboratory analysis used EPA Method SW846 3050B/7000B to test paint chip samples, with lead concentrations ranging from 3.6% to 8.8% by weight on certain components. The report emphasizes the importance of providing this documentation to contractors, current and future property owners to ensure compliance with federal regulations and to maintain awareness of potential lead-based paint hazards.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid Document.pdf | ||
| Required Bid Forms Packet-for IFB.pdf | ||
| 2330 Old Chesterfield Rd_pre bid sign in sheet.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LEAD-BASED PAINT INSPECTION REPORT
2330 Old Chesterfield Road
Longs, South Carolina Asbestos Inspections, LLC Project # 2025-03-017
Performed in general accordance with HUD, EPA, SCDES, along with OSHA regulation 29 CFR 1926.62
Assessment Completed by:
Asbestos Inspections, LLC 4686 Pee Dee Highway
Conway, South Carolina 29527
(843) 995-5197
Dawn Schoolcraft
Lead Paint Inspector #LBP-R-I162035-3
Assessment Completed For:
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue
Conway, South Carolina 29526
Inspection Completed On – January 10, 2025 Report Prepared On – January 23, 2025
Lead-Based Paint Inspection Report 2330 Old Chesterfield Rd
Project Number – 2025-03-017 January 23, 2025
TABLE OF CONTENTS
1.0 SIGNATURE PAGE
2.0 COVER LETTER
3.0 PROJECT INFORMATION
1.1 Scope and Purpose
2.1 Facility Conditions
3.1 Lead-Based Paint Assessment Data
4.1 Conclusions
Appendix 1-Site Location Plan and Sample Location Plan Appendix 2-Photographs Appendix 3-Lead-Based Paint Laboratory Results Appendix 4-License
1.0 SIGNATURE PAGE
This report has been performed at the request of Mr. Sam LoFaso with Horry County Government. The inspection was conducted by Dawn Schoolcraft with Asbestos Inspections, LLC on January 10, 2025. The report was prepared and reviewed by the undersigned inspector.
Inspection Performed by: License# Signature Date
Dawn Schoolcraft LBP-R-I162035-3 Dawn Schoolcraft January 10, 2025
Report Prepared by:
Dawn Schoolcraft LBP-R-I162035-3 Dawn Schoolcraft January 23, 2025
Report Reviewed by:
Dawn Schoolcraft LBP-R-I162035-3 Dawn Schoolcraft January 23, 2025
2.0 COVER LETTER
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue Conway, South Carolina 29526
Subject: Lead-Based Paint Inspection Report 2330 Old Chesterfield Road Longs, South Carolina 29568 Asbestos Inspections, LLC Project # 2025-03-017
Asbestos Inspections, LLC has completed a Lead-Based Paint Inspection for the structure located at 2330 Old Chesterfield Road, in Longs, South Carolina. The inspection was completed on January 10, 2025 by a licensed lead paint inspector.
The following report summarizes the project background, assessment procedures, results, and conclusions. The results presented in this report are indicative of conditions during the time of the inspection and of the specific areas outlined. The information provided in this report should not be used as a bidding document and field conditions should be verified. Should suspect paint coated surfaces, not included within this report, be identified or impacted during the destructive activities, samples must be collected and analyzed for lead content.
Disclosure Responsibility: A copy of this summary must be provided to new lessees (tenants), owners and purchasers of this property under Federal Law (24 CFR part 35 and 40 CFR part 745) before they become obligated under a lease or sales contract. The complete report must also be provided to new purchasers and it must be made available to new tenants. Landlords (lessors) and sellers are also required to distribute an educational pamphlet and include standard warning language in their leases or sales contracts to ensure that parents have the information they need to protect their children from lead-based paint hazards.
I appreciate this opportunity to provide my services. Should you have any questions concerning this report, please contact me at (843) 995-5197.
Sincerely, Lead Paint Inspector (License #LBP-R-I162035-3)
3.0 PROJECT INFORMATION
1.1 Scope and Purpose
Mr. Sam LoFaso with Horry County Government requested this inspection for the structure located at 2330 Old Chesterfield Road in Longs, South Carolina. Based on information obtained from you, the structure is scheduled for demolition. The purpose of this assessment was to identify lead-based paint on building components prior to the scheduled demolition.
The inspection was completed in accordance with procedures specified in the Department of Housing and Urban Development (HUD) 1997 Revision that replaces Chapter 7 Lead-Based Paint Inspection, Environmental Protection Agency (EPA), along with Occupational Safety and Health Administration (OSHA) Lead in Construction Standard regulation 29 Code of the Federal Regulations (CFR) 1926.62. The representative bulk samples collected were analyzed by a laboratory recognized under the Environmental Protection Agencies (EPA) National Lead Laboratory Accreditation Program (NLLAP).
2.1 Facility Conditions
The subject structure is an approximately 786 square feet, single family home with a metal roof, vinyl siding, and wood framed windows. The interior consists of mostly unpainted wood walls and ceilings, with select painted wood walls, and vinyl floor coverings.
The possibility exists that paint coated surfaces were undetected in inaccessible areas such as, locked rooms, behind exterior veneer, pipe chases, or wall voids. If additional suspect paint coated surfaces not included in this report are discovered during renovation, samples should be collected and analyzed for lead content.
3.1 Lead-Based Paint Assessment Data
The assessment was performed by identifying paint coated surfaces associated with the structure in accordance with HUD and EPA guidelines. One paint chip sample was collected for each painted surface of the structure’s building components, which includes but is not limited to shutters, siding, exterior trim, window trim, windowsills, interior and exterior doors, door frames, walls, baseboards, chair rails and floors. The samples collected were approximately 1-4 square inches in size and included all layers of paint, placed inside an appropriate sample container, and labeled accordingly using a unique identification number. A chain of custody was completed for the samples with project specific information and then submitted to Eurofins/CEI for analysis. The samples collected were analyzed via EPA Method SW846 3050B/7000B. The following outlines the paint chip samples collected and analyzed:
Sample
Substrate Component Color Paint Location Condition Lead Concentration
(% by weight) P1 Wood Window Frame Black Exterior of Living Room Intact 6.4
Sample
Substrate Component Color Paint Location Condition Lead Concentration
(% by weight) P2 Wood Window Frame Black Exterior of Kitchen/Dining Intact 8.8 P3 Wood Floor Gray Rear Porch Intact <0.0050 P4 Wood Framing White Front Porch Intact <0.0040 P5 Wood Floor Gray Front Porch Intact <0.0050 P6 Wood Column Black Front Porch Intact 3.6 P7 Wood Interior Wall Blue Dining Intact <0.0076 P8 Wood Interior Door Dark Red Dining Intact <0.0088
Condition Assessment Key
Type of Bldg. Component Total Area of Deteriorated Paint on Each Component
Intact Fair1 Poor2
Exterior components with large surface area
Entire surface area is intact
Less than or equal to 10 square feet
More than 10 square feet
Interior components with large surface area
Entire surface area is intact
Less than or equal to 2 square feet
More than 2 square feet
Interior and exterior components with small surface areas
Entire surface area is intact
Less than or equal to 10% of the total surface area of component
More than 10% of the total surface area or the component
Superscript 1 = surfaces in “fair” condition should be repaired and/or monitored but are not considered to be lead based paint hazards.
Superscript 2 = surfaces in “poor” condition are considered to be lead based paint hazards as defined by Title X and should be addressed through abatement or interim controls.
Site location plan and sample locations are identified as Figures 1 and 2 in Appendix 1 of this report, photographs are in Appendix 2, lead-based paint lab results are in Appendix 3, and licenses are in Appendix 4.
4.1 Conclusions
HUD and EPA defines paint as lead-based if an amount greater than 1.0 mg/cm2 or 0.5 percent by weight is identified in a paint chip sample and SCDES defines lead paint as greater than 0.7 mg/cm2. The results of this inspection indicate that lead was found in concentrations greater than or equal to 1.0 mg/cm2 or 0.5 percent by weight was identified on the building components sampled and analyzed for the structure located at 2330 Old Chesterfield Road, in Longs, South Carolina:
Black exterior wood window frames Black wood columns on Front Porch
A copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations. Additionally, this report should be kept by the owner and future owners for the life of the dwelling.
Site Location Plan and Sample Location Plan
Photographs
Site Photos
Exterior, Front
Exterior
Exterior, Porch
Living Room
Living Room
Door
Bedroom
Kitchen/Dining
Bathroom
Kitchen
Laboratory Results
Certifications
F
12884, 06/30/2025, North Carolina, Dawn
Schoolcraft 1909008, 09/30/2025, South Carolina, Dawn
LBP-R-I162035-3, 03/16/2027, South Carolina, BI-00738, 06/03/2025, South Carolina, Dawn