23.00144_Heatlok_HFO_EZ_TDS_Web_v5.pdf

PDF 126 KB Posted

Attached to
DAS Building 5 Insulation
Solicitation number
2024-0912FM
Issued by
Collier County, Florida

About this file

This document is a Technical Data Sheet (TDS) for Heatlok® HFO EZ, a spray-applied polyurethane foam insulation product manufactured by Huntsman Building Solutions, with application limited to specific states including Alabama, Arizona, California, Florida, Georgia, Louisiana, Mississippi, New Mexico, North Carolina, Nevada, Oklahoma, South Carolina, Tennessee, and Texas. The product is a two-component, closed-cell rigid polyurethane foam system that uses recycled plastic materials and rapidly renewable soy oils, designed for thermal insulation, air barrier, vapor retarder, and water-resistive barrier applications in above-grade, below-grade, interior, and exterior settings.

The technical data sheet provides comprehensive specifications including physical properties, fire test results, and recommended processing parameters. Key technical attributes include a core density of 2.0-2.3 lb/ft³, an R-value of 7.0 at 1" and 24 at 3.5", and compliance with International Code Council residential and commercial building codes. The product has passed various fire and thermal barrier tests, including ASTM E84 surface burning characteristics and NFPA 286 thermal barrier compliance. Processing requirements include specific substrate conditions, maximum pass thickness of 2" per layer, and careful temperature and pressure management during application, with detailed guidelines for proper installation and safety considerations.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HEATLOK® HFO EZ

TECHNICAL DATA SHEET

ASTM D 1622 Core Density 2.0 – 2.3 lb/ft³

ASTM C 518 Aged Thermal Resistance R-Value 7.0 @ 1" R-Value 24 @ 3.5"

ASTM E 2178 Air Permeance @ 75 Pa @ 1 < 0.02 L/sm²

ASTM E 96 Class II vapor retarder @ ≤ 1 perm 1” 25.4mm

ASTM D 1621 Compressive Strength 31 psi 214 kPa

ASTM D 1623 Tensile Strength 44 psi 303 kPa

The application of Heatlok® HFO EZ is limited to AL, AR, AZ, CA, FL, GA, LA, MS, NM, NC, NV, OK, SC, TN, and TX.

Heatlok® HFO EZ is a two component, closed cell, spray applied, rigid polyurethane foam system. This product uses recycled plastic materials, rapidly renewable soy oils, and the blowing agent has zero ozone depleting potential. Heatlok HFO EZ complies with the intent of the International Code Council’s residential and commercial building codes and is commonly used as a thermal insulation, air barrier, vapor retarder and water resistive barrier in above grade, below grade, interior and exterior applications.

PHYSICAL PROPERTIES

REACTIVITY PROFILE

Cream Time Gel Time Tack Free Time End of Rise 0 – 1 seconds 2 seconds 3 – 4 seconds 3 – 4 seconds

PROPERTY A-PMDI ISOCYANATE HEATLOK HFO EZ RESIN

Color Brown Amber

Viscosity @ 77°F (25°C) 180 – 220 cps 500 – 800 cps

Specific Gravity 1.24 1.17 – 1.21

Shelf Life of unopened drum properly stored 12 months 6 months

Storage Temperature 50 – 100°F (10 – 38°C) 59 – 77°F (15 – 25°C)

Mixing Ratio (volume) 1:1 1:1

LIQUID COMPONENT PROPERTIES

*See SDS for more information.

FIRE TEST RESULTS

ASTM E 84

Surface Burning Characteristics, 4” thick Class I

Flame Spread Index <25 Smoke Developed <450

AC 377 Appendix X Ignition Barrier – Compliant with 2012, 2015, 2018 & 2021 IBC and IRC, and ICC-ES

AC-377 Appendix X, for use in attics and crawl spaces without a prescriptive ignition barrier or Pass intumescent coating.

NFPA 286

Thermal Barrier – Compliant with the 2012, 2015, 2018 & 2021 IBC and IRC, as an interior finish without a

15 minute thermal barrier when coated with:

DC-315 wet film thickness 18 mils dry film thickness 12 mils

No-Burn Plus ThB wet film thickness 16 mils dry film thickness 11 mils

Pass

3315 E Division St Arlington, TX 76011

Phone: (817) 640-4900 www.huntsmanbuildingsolutions.com

AN: 23.00144 | REV: 02.09.24

*Foam application temperatures and pressures can vary widely depending on temperature, humidity, elevation, substrate, equipment and other factors. While processing, the applicator must continuously observe the characteristics of the sprayed foam and adjust processing temperatures and pressures to maintain proper cell structure, adhesion, cohesion and general foam quality. It is the sole responsibility of the applicator to process and apply Heatlok HFO EZ within specification.

General Requirements: The application of Heatlok HFO EZ is limited to AL, AR, AZ, CA, FL, GA, LA, MS, NM, NC, NV, OK, SC, TN, and TX.

Equipment must be capable of delivering the proper ratio (1:1 by volume) of polymeric isocyanate (PMDI) and polyol blend at adequate temperatures and spray pressures. Substrate must be at least 5 degrees above dew point, with best processing results when ambient humidity is below 80%. Substrate must also be free of moisture (dew or frost), grease, oil, solvents and other materials that would adversely affect adhesion of the polyurethane foam. Applicators should limit the application of this product to no more than a thickness of 2” (50mm) per pass (after expansion) to avoid fire hazards (including spontaneous combustion) resulting from excessive heat generation. A second 2” (50mm) layer may be applied immediately after the first one has fully risen. if subsequent passes are needed, applicators should wait until the core temperature of the foam has dropped below 100°F to allow any reaction heat to dissipate from the prior applications before attempting to reapply the product.

RECOMMENDED MAXIMUM PASS THICKNESSES

Maximum Pass 2” 50mm

Dual Pass (x” + x”) 2” + 2” 50mm + 50mm

Heatlok HFO EZ must be separated from the interior of the building by an approved thermal barrier or an approved finish material equivalent to a thermal barrier in accordance with applicable codes. Heatlok HFO EZ must be sprayed at a minimum thickness of 1” per pass. This product must not be used when the continuous service temperature of the substrate or foam is below -60°F (-51°C) or above 180°F (82°C). Heatlok HFO EZ should not be used to cover flexible ductwork.

Disclaimer: The information herein is to assist customers in determining whether our products are suitable for their applications. We request that customers inspect and test our products before use and satisfy themselves as to contents and suitability. Nothing herein shall constitute a warranty, expressed or implied, including any warranty of merchantability or fitness, nor is protection from any law or patent inferred. All patent rights are reserved. The foam product is combustible and must be protected in accordance with applicable codes. Protect from direct flame and spark contact, around hot work for example. The exclusive remedy for all proven claims is replacement of our materials.

RECOMMENDED PROCESSING PARAMETERS

Initial Primary Heater Setpoint Temperature 105 - 115º F

105 - 115º F

1200 - 1400 PSI

> 50° F ≤19%

Initial Hose Heat Setpoint Temperature*

Initial Processing Setpoint Temperature

Substrate & Ambient Temperature

Moisture Content of Substrate

Moisture Content of Concrete Concrete must be cured, dry, and free of dust and form release agents.

EXTERIOR WALL SYSTEM COMPONENT

IN ACCORDANCE WITH NFPA 285

SEE BUILDING MATERIALS DIRECTORY

ALSO CLASSIFIED IN ACCORDANCE WITH ASTM D1929

FILE R39899

MADE IN USA

File details come from the government source that posted it. Updated .