23-422409.1_Limited_ACM_Survey_McCHS-Asbestos.pdf
PDF 3 MB Posted
- Solicitation number
- 27-016CH-27IFB
- Issued by
- Maricopa County, Tucson City, Arizona
About this file
This is a Limited Asbestos Survey Report prepared by Partner Engineering and Science, Inc. for the Tempe Union High School District #213, assessing McClintock High School located at 1830 East Del Rio Drive in Tempe, Arizona. The survey was conducted on January 29, 2024, in anticipation of a planned roofing repair project at the educational facility, which comprises 20 buildings with up to 3 floors. The assessment involved 129 bulk material samples collected from accessible roofing areas identified for repair, with laboratory analysis performed using Polarized Light Microscopy (PLM) in accordance with EPA Method 600/R-93-116. The survey identified one homogenous area containing asbestos-containing material (ACM): Built-Up Roofing with Gray Mineral Cap located on the Gym Annex roof, measuring approximately 8,000 square feet and containing 25% Chrysotile asbestos in good condition, classified as NESHAP Category I non-friable ACM. The survey was limited to damaged roofing materials previously identified for repair and did not include destructive testing or disassembly of equipment.
The report recommends that all friable ACM and non-friable ACM that will be disturbed by the forthcoming renovation activities be removed prior to disturbance in compliance with federal, state, and local regulations, including EPA NESHAP (40 CFR 61, Subpart M) and OSHA asbestos standards (29 CFR 1910.1001 and 1926.1101). Regulatory notifications, specialized removal techniques, cleanup procedures, and waste disposal must be implemented to prevent worker, public, and environmental exposures. The survey explicitly notes that additional uncharacterized suspect ACM may be encountered during renovation activities and must be assumed to be ACM pending further sampling and analysis. The report serves as a reference for managing the identified ACM during the scheduled roofing replacement project anticipated by the related invitation for bids (IFB #27-016CH-27IFB) with a submission deadline of December 9, 2026.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| McClintock_Roofing_Replacement-IFB_#27-016CH-27IFB.pdf | ||
| Amendment_Acknowledgment.docx | DOCX document | |
| Forced_Labor_of_Ethnic_Uyghurs_Ban.docx | DOCX document | |
| Vendor_Reference_Listing.xlsx | XLSX spreadsheet | |
| W-9_(2024)_FILLABLE.pdf | ||
| Vendor_Registration_Form_FILLABLE.pdf | ||
| Non-Collusion_Affidavit.pdf | ||
| Offer_and_Acceptance_Form.pdf | ||
| McClintock_2026-10-13.pdf | ||
| 2024-04-12_McClintock_HS_Roofing_Renovation.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LIMITED ASBESTOS
SURVEY REPORT
McClintock High School Roofing Repairs 1830 East Del Rio Drive Tempe, Arizona 85282
Report Date February 14, 2024
Partner Project No.
23-422409.1
Prepared for:
ADM Group Inc.
Tempe, Arizona 85281 www.PARTNEResi.com
February 14, 2024
Mr. Jason Olive ADM Group, Inc.
2100 West 15th Street Tempe, Arizona 85281
Subject: Limited Asbestos Survey Report McClintock High School 1830 East Del Rio Drive Tempe, Arizona 85282 Partner Project No. 23-422409.1
Dear Mr. Olive:
Partner Engineering and Science, Inc. (Partner) is pleased to provide the Limited Asbestos Survey Report of the abovementioned address (the “Subject Property”). This survey included a site reconnaissance to locate, identify, assess, and quantify suspect asbestos containing materials (ACM).
The purpose of this survey was to sample and determine the condition of accessible suspect ACM on the roofs of the buildings that will be impacted by scheduled renovation activities. Partner has been provided with specific renovation plans. This survey included a site reconnaissance, material sampling, and laboratory analysis. This assessment was performed utilizing methods and procedures consistent with good commercial or customary practices designed to conform to acceptable industry standards. The independent conclusions presented herein are based upon existing conditions and the information and data available to us during the course of this assignment.
We appreciate the opportunity to provide industrial hygiene services to ADM Group, Inc. If you have any questions concerning this report, or if we can assist you in any other matter, please contact me at 602.380- 4258 or panger@partneresi.com.
Sincerely, Partner Engineering and Science, Inc.
Paul Anger Sr. Project Manager
Limited Asbestos Survey Report Project No. 23-422409.1 February 14, 2024 Page i
EXECUTIVE SUMMARY
Partner is pleased to present this report for this Limited Asbestos Survey of various roofs at McClintock High School located at 1830 East Del Rio Drive in Tempe, Arizona 85282. The survey was conducted in general conformance with the National Emission Standards for Hazardous Air Pollutants (NESHAP) regulation.
Based on the conditions set forth in this report, the following confirmed, suspect, or assumed ACM were identified:
Built-Up Roofing with Gray Mineral Cap; Good Condition; NESHAP Category – I; 25% Chrysotile; – Estimated 8,000 sf
If any suspect ACM not characterized in this report are encountered during renovation activities, all work that could potentially disturb the material must stop. The uncharacterized suspect ACM must be assumed to be ACM and handled accordingly pending the completion of additional sampling and laboratory analysis.
This was a non-destructive survey limited to damaged roofing materials that were previously identified to be repaired. Suspect ACM could be in areas not accessed during this assessment. A comprehensive ACM survey should be completed to verify the presence, location, and quantity of additional suspect ACM, in accordance with United States (US) Environmental Protection Agency (EPA) regulation 40 CFR Part 61, Subpart M (NESHAP), the Occupational Safety and Health Administration (OSHA) 29 CFR 1926.1101 (Asbestos in Construction Standard), and any state or local requirements.
February 14, 2024 Page ii
TABLE OF CONTENTS
1.0 INTRODUCTION
1.1 Subject Property Description
1.2 Purpose and Scope
2.0 METHODOLOGY
2.1 Visual Evaluation
2.2 Classification
2.3 Evaluation of Condition
2.4 Homogenous Areas
2.5 NESHAP Categorization
3.0 SAMPLING AND LABORATORY ANALYSIS
4.0 LIMITING CONDITIONS
5.0 ANALYTICAL RESULTS
6.0 CONCLUSIONS AND RECOMMENDATIONS
6.1 Conclusions
6.2 Recommendations
7.0 LIMITATIONS
8.0 SIGNATURES OF PROFESSIONALS
The following Appendices are attached at the end of this report.
Appendices Appendix A: Sampled Building Materials Table Appendix B: ACM Location Diagram Appendix C: Sample Location Diagrams, Chain-of-Custody and Laboratory Analysis Appendix D: Certifications/Licenses Appendix E: Photographic Documentation
February 14, 2024
1.0 INTRODUCTION
1.1 Subject Property Description
Address: 1830 East Del Rio Drive, Tempe, Arizona 85282 Nature of Use: Educational Number of Buildings: 20 Number of Floors: 3 Construction Date(s) Unknown Surveyed By / License Number: Paul Anger, Inspector License Number ON-4644-13908-040423, expiration date: April 4, 2024 Assessment Date/Time: January 29, 2024
1.2 Purpose and Scope
The survey was conducted at the Subject Property due to a planned roofing repair project. US EPA regulation 40 CFR 61, Subpart M, NESHAP, prohibits the release of asbestos fibers and other hazardous air pollutants to the atmosphere during renovation or demolition activities. Asbestos NESHAP requires the identification, classification, and quantification of potentially regulated ACM (RACM) prior to any planned disturbances.
The purpose of this survey was to investigate the condition of accessible suspect asbestos on the roofs that will be impacted by scheduled repair activities. Partner has been provided with renovation plans. Sampling conducted was intended as indicative of the materials tested and was not intended to conclusively determine the absence of ACM. Asbestos may be present in materials not sampled, and additional sampling will be warranted in the event of future disturbance of suspect materials not identified within this report.
Additional services such as the interview of property management and maintenance personnel, tenants, review of prior reports, regulatory records, evaluation of compliance, risk assessment, and the development of abatement specifications were excluded from the scope of services, along with all other activities not expressly identified herein. No destructive demolition, destructive testing, product research was performed in attempts to reveal material compositions.
This work is not intended as a specification for asbestos abatement or to otherwise support bidding for or completion of maintenance, abatement, removal or replacement activities. Quantification of the exact quantities of materials is beyond the scope of this survey. Any quantities of ACM listed are estimates only and should be confirmed by the user.
Partner and its subcontractor, Eurofins Aerotech Built Environment Testing, Inc. (Eurofins), and their employees/representatives bear no responsibility for the actual condition of the structure or safety of this site pertaining to asbestos and/or asbestos contamination regardless of the actions taken by the survey team or the client.
February 14, 2024
2.0 METHODOLOGY
Provided below is a summary of the methodologies used during the Limited Asbestos Survey performed at the subject property. The methodology is in general conformance with US EPA Asbestos Hazard Emergency Response Act (AHERA), 40 CFR Part 763.
2.1 Visual Evaluation
Building materials were observed to identify, classify and evaluate the condition of homogenous areas (HA) of suspect ACM. The roofs were observed to consist of asphaltic built-up and spray-applied foam systems.
A summary of the HA’s identified during the survey and the condition of the materials comprising these areas is provided in Appendix A.
2.2 Classification
ACM is typically classified as surfacing, thermal systems insulation, or miscellaneous, as defined below:
Surfacing - Material that is sprayed-on, troweled-on or otherwise applied to surfaces. Examples include acoustical plaster on ceilings, fireproofing on structural members, or similar applications for acoustical, fireproofing, and other purposes.
Thermal Systems Insulation – Materials applied to pipes, fittings, boilers, breeching, tanks, ducts or other structural components to prevent heat loss or gain.
Miscellaneous – All other material including flooring, mastics, caulking, etc.
2.3 Evaluation of Condition
An assessment of the condition of ACM is useful in deciding how to manage those materials. The ACM most likely to release asbestos fibers are those which are in a friable state. The definition of friable is any material, when dry, that is capable of being crumbled, pulverized, or reduced to powder by hand pressure (AHERA). Non-friable asbestos materials containing cement or asphaltic binder may become friable and release fibers if exposed to actions such as abrasion, drilling, cutting, fracturing, or hammering. Non-friable asbestos materials do not typically pose a significant exposure risk if they remain in good condition and are not disturbed. During renovation activities or when subject to abrasive action, non-friable materials may become friable and thus may pose an exposure risk.
US EPA AHERA protocols were used in the evaluation of the condition of observed materials. The condition of materials was based upon observations at the time of the assessment and was independent of the friable or non-friable nature of the materials.
Good condition = 1% or less damage for both distributed and localized damage.
Damaged = >1% to 10% damage if distributed or >1% to 25% damage if localized.
Significantly Damaged= >10% damage if distributed or >25% damage if localized.
February 14, 2024
2.4 Homogenous Areas
The US EPA defines an HA as “an area of surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color and texture” (40 CFR 763). If asbestos is identified in any samples from an HA, the entire HA is considered to contain asbestos. The number of samples required per HA to determine if that HA is a non-ACM is outlined in 40 CFR §763.86 Sampling.
2.5 NESHAP Categorization
If a sampled material is confirmed to be asbestos-containing or is assumed to be ACM by the accredited inspector, that material will be categorized according to whether its disturbance is regulated. The Asbestos NESHAP (40 CFR 61, Subpart M) defines confirmed or suspect ACMs in three (3) categories: RACM, Category I and Category II non-friable ACM.
RACM - Friable ACM; Category I non-friable ACM that has become friable; Category I ACM that will be or has been subjected to sanding, grinding, cutting or abrading; or Category II non-friable that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition operations regulated by the Asbestos NESHAP regulation .
Category I Non-Friable - ACM packings, gaskets, resilient floor covering and asphalt roofing.
Category II Non-Friable - Any other non-friable ACM material that is not Category I Non-Friable that when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure (example transite).
February 14, 2024
3.0 SAMPLING AND LABORATORY ANALYSIS
During this survey, 129 samples of suspect ACM were collected for laboratory analysis. Selected materials were analyzed using the Polarized Light Microscopy (PLM) method in accordance with the EPA Method 600/R-93/116 for Determination of Asbestos in Bulk Building Materials.
Federal and Arizona regulations define ACM as any material containing more than one percent (1%) asbestos.
The table in Section 5 provides a summary of the condition of the identified ACM. A summary of the HA identified during the survey and the condition of the materials comprising these areas is provided in Appendix A.
February 14, 2024
4.0 LIMITING CONDITIONS
The performance of this survey was limited by the following conditions:
Sampling activities were limited to damaged roofing materials that are identified to be repaired.
Materials that would negatively impact the appearance or operation of the subject property were not sampled unless expressly directed by the client.
The survey was limited to areas which were considered readily accessible. No disassembly of equipment or accessing pipe chases, wall cavities or other inaccessible areas was conducted.
The sampling of architectural finishes was limited where negative impacts to the appearance of such finishes would be likely to result, and no sampling of water-protective assemblies has been conducted.
Laboratory analysis was limited to evaluation of asbestos content by PLM, with a detection limit of 1%. Additional analysis, by point count or Transmission Electron Microscopy (TEM), may be required to meet state or local requirements.
Additional ACM may be located within areas that were not accessed.
February 14, 2024
5.0 ANALYTICAL RESULTS
The following table lists the ACM identified by PLM, Point Count and TEM-Chatfield analysis (if applicable), including the condition and quantity of each material. The analytical results for all suspect materials sampled are listed in Appendix A. The ACM location diagram is included in Appendix B. The sample location diagrams, chain-of-custody and laboratory results are included in Appendix C.
Documentation of the laboratory results should be retained as a reference for any future disturbance to the suspect ACMs identified within this report.
Identified ACM Material
No.
Description Location Est. Quant. ACM %
M-BUR-19 Built-Up Roofing with Gray Mineral Cap Gym Annex - 1014 Roof 8,000 sf 25% Chrysotile
February 14, 2024
6.0 CONCLUSIONS AND RECOMMENDATIONS
6.1 Conclusions
Based on the conditions set forth in this report, the following confirmed, suspect, or assumed ACM were identified:
Built-Up Roofing with Gray Mineral Cap; Good Condition; NESHAP Category – I; 25% Chrysotile; – Estimated 8,000 sf
6.2 Recommendations
Partner recommends that all friable ACM or non-friable ACM that will be disturbed by the forthcoming renovation activities be removed prior to disturbance according to local, State and Federal regulations.
RACM are friable or potential friable ACM and all notification and emission control requirements apply based on amount of material. This effort may include:
o Regulator notification o Specialized removal techniques to prevent worker, public and environmental exposures o Specialized clean-up procedures o Specialized waste storage and disposal
Actions taken in regard to the ACM should be in compliance with any applicable Federal, State, and local regulations or codes that may apply to handling, disposal, and contracting. Presently, general renovation and disposal operations at both publicly and privately owned and operated facilities are regulated by the federal US EPA NESHAP Asbestos Standard (40 CFR 61, Subpart M). Contractors who may be retained by a building owner and the building owner itself, are under jurisdiction of OSHA asbestos regulations (29 CFR
1910.1001 and 29 CFR 1926.110 for the general and construction industries, respectively), which regulates workplace disturbance of building materials with any concentration of asbestiform components including those that contain<1% asbestos as determined by a validated sampling and analytical method.
Alternatives to removal: The US EPA recommends that ACM be managed in-place whenever asbestos is identified in a building and will not be disturbed. Damaged friable and non-friable ACMs can be repaired, encapsulated, or enclosed according to Federal, State, and local requirements. Intact ACMs in good condition, if the planned renovations are not imminent, can be managed with an Operations and Maintenance (O&M) Plan. Of note, an O&M Plan outlines protocols that have been established to mandate how ACM are managed on an as needed basis and during routine maintenance activities. Routine maintenance activities include cleaning activities; protective or preventative measures to keep a building, its systems and its grounds in working order; periodic replacement of a limited number of component parts of a building feature or system that are subject to normal wear and tear; and replacement of a damaged or malfunctioning component part of a building feature or system. The US EPA recommends “the least burdensome method with protects human health and the environment.”
February 14, 2024
7.0 LIMITATIONS
Sampling was performed utilizing methods and procedures consistent with good commercial or customary practices. The results of this sampling event cannot conclusively determine the absence of ACM at the property per the local, State or Federal sampling protocol(s); however, the results of the sampling conducted at this property can be used to supplement a further survey of the property for regulatory compliance reasons.
This work is not intended as a specification for asbestos abatement or to otherwise support bidding for or completion of maintenance, abatement, removal or replacement activities. Quantification of the exact quantities of materials is beyond the scope of this survey. Any quantities of ACM listed are estimates only and should be confirmed by the Client.
Partner subcontracted with Eurofins to perform the asbestos analysis. No warranties expressed or implied, are made by Partner or its subcontractor Eurofins or their employees as to the use of any information, apparatus, product or process disclosed in this report. Every reasonable effort has been made to assure correctness. If an Asbestos Abatement Contractor or other Demolition/Construction Contractor is employed, such contractor should bring any discrepancies found in this report as it relates to current site conditions or newly discovered site conditions to the immediate attention of Partner.
State-of-the-art practices have been employed to perform this asbestos survey. No demolition or product research was performed in attempts to reveal material compositions. Additional sampling may be required if demolition/renovation activities reveal any materials not previously tested. The services consist of professional opinions and recommendations made in accordance with generally accepted engineering principles/practices. These services are designed to provide an analytical tool to assist the client. Partner and its subcontractor Eurofins and their employees/representatives bear no responsibility for the actual condition of the structure or safety of this site pertaining to asbestos and/or asbestos contamination regardless of the actions taken by the survey team or the client.
February 14, 2024
8.0 SIGNATURES OF PROFESSIONALS
Partner has performed an asbestos survey on the property at McClintock High School located at 1830 East Del Rio Drive in Tempe, Arizona 85282 in general conformance with the scope and limitations of the protocol and the limitations stated earlier in this report. Exceptions to or deletions from this protocol are discussed earlier in this report.
Prepared By:
Paul Anger
Sr. Project Manager
Reviewed By:
Rod L. Pawloski
Sr. Project Manager
APPENDIX A: SAMPLED BUILDING MATERIALS TABLE
Sampled Building Materials
Sample No. Material Category
Type of Material Condition Location ACM %
M-BUR-01A
M Built-Up Roofing with
White Coating G Administration – 1010 Roof
ND
M-BUR-01B ND
M-BUR-01C ND
M-BUR-02A
M Built-Up Roofing with Gray Mineral Cap G Building 100 – 1002
Roof
ND
M-BUR-02B ND
M-BUR-02C ND
M-BUR-03A
M Built-Up Roofing with Gray Mineral Cap G Building 200 – 1003
Roof
ND
M-BUR-03B ND
M-BUR-03C ND
M-BUR-04A
M Built-Up Roofing with Gray Mineral Cap G Building 300 – 1004
Roof
ND
M-BUR-04B ND
M-BUR-04C ND
M-BUR-05A
M Built-Up Roofing with White Coating G Library - 1020 Roof
ND
M-BUR-05B ND
M-BUR-05C ND
M-BUR-06A
M Built-Up Roofing with White Coating G Building 500 – 1006
Roof
ND
M-BUR-06B ND
M-BUR-06C ND
M-BUR-07A
M Built-Up Roofing with White Coating G Building 600 – 1007
Roof
ND
M-BUR-07B ND
M-BUR-07C ND
M-BUR-08A
M Built-Up Roofing with Gray Mineral Cap G Cafeteria – 1021, 1022, 1023 Roof
ND
M-BUR-08B ND
M-BUR-08C ND
M-MAS-09A
M Mastic (Flashing, Penetration), Black G Cafeteria – 1021, 1022, 1023 Roof
ND
M-MAS-09B ND
M-MAS-09C ND
M-FLA-10A
M Flashing (Aluminum Cap), Silver G Cafeteria – 1021, 1022, 1023 Roof
ND
M-FLA-10B ND
M-FLA-10C ND
M-CTG-11A
M Coating (Flashing), White G Cafeteria – 1021, 1022, 1023 Roof
ND
M-CTG-11B ND
M-CTG-11C ND
M-PPS-12A
M Pitch Pan Sealant, Gray G Cafeteria – 1021, 1022, 1023 Roof
ND
M-PPS-12B ND
M-PPS-12C ND
M-SLT-13A
M Sealant (Flashing), Light Gray G Cafeteria – 1021, 1022, 1023 Roof
ND
M-SLT-13B ND
M-SLT-13C ND
M-MAS-14A
M Mastic (Penetration), Black G Cafeteria – 1021, 1022, 1023 Roof
ND
M-MAS-14B ND
M-MAS-14C ND
M-MAS-15A
M Mastic (Roof Seams), Black G Cafeteria – 1021, 1022, 1023 Roof
ND
M-MAS-15B ND
M-MAS-15C ND
Category
Type of Material Condition Location ACM %
M-CTG-16A
M Coating (Spray-Applied
Foam Roofing), White G Cafeteria – 1021, 1022, 1023 Roof
ND
M-CTG-16B ND
M-CTG-16C ND
M-BUR-17A
M Built-Up Roofing with White Coating G Building 700 – 1008
Roof
ND
M-BUR-17B ND
M-BUR-17C ND
M-BUR-18A
M Built-Up Roofing with White Coating G Building 700 – 1009
Roof
ND
M-BUR-18B ND
M-BUR-18C ND
M-BUR-19A
M Built-Up Roofing with Gray Mineral Cap G Gym Annex - 1014
Roof
ND
M-BUR-19B ND
M-BUR-19C 25% Chrysotile
M-BUR-19D ND
M-BUR-19E ND
M-MAS-20A
M Mastic (Flashing, Penetration), Black G Gym Annex - 1014 Roof
ND
M-MAS-20B ND
M-MAS-20C ND
M-SLT-21A
M Sealant (Pitch Pan), Gray G Gym Annex - 1014 Roof
ND
M-SLT-21B ND
M-SLT-21C ND
M-SLT-22A
M Sealant (Penetration), White G Gym Annex - 1014 Roof
ND
M-SLT-22B ND
M-SLT-22C ND
M-SLT-23A
M Sealant (Pitch Pan), Black G Gym Annex - 1014 Roof
ND
M-SLT-23B ND
M-SLT-23C ND
M-SLT-24A
M Sealant (Reglet), Off- White G Gym Annex - 1014 Roof
ND
M-SLT-24B ND
M-SLT-24C ND
M-CTG-25A
M Coating (Spray-Applied Foam Roofing), White G Chiller Plant Roof
ND
M-CTG-25B ND
M-CTG-25C ND
M-BUR-26A
M Built-Up Roofing with White Coating G Gym – 1012, 1013 Roof
ND
M-BUR-26B ND
M-BUR-26C ND
M-BUR-26D ND
M-FLA-27A
M Flashing (Aluminum Cap) with White Coating G Gym – 1012, 1013 Roof
ND
M-FLA-27B ND
M-FLA-27C ND
M-BUR-28A
M Built-Up Roofing with Gray Mineral Cap G Building 1500 - 1024
Roof
ND
M-BUR-28B ND
M-BUR-28C ND
M-BUR-29A
M Built-Up Roofing with White Coating G Weight Room Roof
ND
M-BUR-29B ND
M-BUR-29C ND
Category
Type of Material Condition Location ACM %
M-FLA-30A
M Flashing (Aluminum
Cap) with White Coating G Weight Room Roof
ND
M-FLA-30B ND
M-FLA-30C ND
M-SLT-31A
M Sealant (Roof Seams), White G Weight Room Roof
ND
M-SLT-31B ND
M-SLT-31C ND
M-BUR-32A
M Built-Up Roofing with White Gravel Cap G
Building 800 – 1010, 1018, 1019, 1024, 1027, 1028, 1030 Roof
ND
M-BUR-32B ND
M-BUR-32C ND
M-BUR-33A
M Built-Up Roofing with Gray Mineral Cap G
Building 800 – 1010, 1018, 1019, 1024, 1027, 1028, 1030 Roof
ND
M-BUR-33B ND
M-BUR-33C ND
M-MAS-34A
M Mastic (Penetration), Black G
Building 800 – 1010, 1018, 1019, 1024, 1027, 1028, 1030 Roof
ND
M-MAS-34B ND
M-MAS-34C ND
M-SLT-35A
M Sealant (Reglet), Off- White G
Building 800 – 1010, 1018, 1019, 1024, 1027, 1028, 1030 Roof
ND
M-SLT-35B ND
M-SLT-35C ND
M-FLA-36A
M Flashing (Aluminum Cap), Silver G
Building 800 – 1010, 1018, 1019, 1024, 1027, 1028, 1030 Roof
ND
M-FLA-36B ND
M-FLA-36C ND
M-SLT-37A
M Sealant (Reglet), Gray G Building 800 – 1010, 1018, 1019, 1024, 1027, 1028, 1030 Roof
ND
M-SLT-37B ND
M-SLT-37C ND
M-CTG-38A
M Coating (Roof), White G Building 800 – 1010, 1018, 1019, 1024, 1027, 1028, 1030 Roof
ND
M-CTG-38B ND
M-CTG-38C ND
M-BUR-39A
M Built-Up Roofing with White Coating G
Building 800 – 1010, 1018, 1019, 1024, 1027, 1028, 1030 Roof
ND
M-BUR-39B ND
M-BUR-39C ND
M-SLT-40A
M Sealant (Pitch Pan), Light Gray G
Building 800 – 1010, 1018, 1019, 1024, 1027, 1028, 1030 Roof
ND
M-SLT-40B ND
M-SLT-40C ND
M-BUR-41A
M Built-Up Roofing with Gray Mineral Cap G
Building 800 – 1010, 1018, 1019, 1024, 1027, 1028, 1030 Roof
ND
M-BUR-41B ND
M-BUR-41C ND
M-CTG-42A
M Coating (Spray-Applied Foam Roofing), White G Maintenance
ND
M-CTG-42B ND
M-CTG-42C ND
APPENDIX B: ACM LOCATION DIAGRAM
APPENDIX B: ACM LOCATIONS
KEY
Built-Up Roofing with Gray Mineral Cap
APPENDIX C: SAMPLE LOCATION DIAGRAMS, CHAIN OF
CUSTODY AND LABORATORY RESULTS
APPENDIX C: SAMPLE LOCATIONS
27B
28B
28C
39A
39C
39B
26D
41C
41A
36-37A-C
19A
20-24A
19B
20-24B
27A
26A
18A
17A
18B
17C
17B
27C
26C
18C
26B
38A-C
33A
33B
32B
33C
29A
29B
29C
28A
19D
30-31A-C
19C
19E
20-24C
15C
08A
14A-C
05C
07A
07C
07B
06C
06A
06B
16A-C
09A-C
11A-C
10A-C
12C
04A
08B
04C
04B
03B
03C
03A
05A
01C
02A
05B
02C
02B
01A
15A
13A-C
12A
15B
12B
08C
25B
25C
25A
01B
32A
42C
42A
42B
34-35C
41B
32C
34-35A
34-35B
Approved by:
Approved Signatory Renee Luna-Trepczynski
Report for:
Paul Anger Partner Engineering & Science, Inc. - Southwest 4518 North 12th Street Suite 201 Phoenix, AZ 85014
Regarding:
Eurofins Aerotech Built Environment Testing, Inc.
Project: McClintock HS Roofing
EML ID: 3523372
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.
Eurofins Aerotech Built Environment Testing, Inc. ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.
Dates of Analysis:
Asbestos PLM: 02-03-2024 and 02-05-2024
Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267) NVLAP Lab Code 500031-0
EMLab ID: 3523372, Page 1 of 43Eurofins Aerotech Built Environment Testing, Inc.
Eurofins Aerotech Built Environment Testing, Inc.
1501 West Knudsen Drive, Phoenix, AZ 85027
(800) 651-4802 www.eurofinsus.com/BuiltClient: Partner Engineering & Science, Inc. - Southwest C/O: Paul Anger Re: McClintock HS Roofing
Date of Sampling: 01-29-2024 Date of Receipt: 01-31-2024 Date of Report: 02-07-2024
ASBESTOS PLM REPORT
Total Samples Submitted: 129 Total Samples Analyzed: 129
Total Samples with Layer Asbestos Content > 1%: 1
Location: M-BUR-01A, Roofing Lab ID-Version‡: 17209639-1
Sample Layers Asbestos Content Brown/Black Fibrous Material ND
Black Roofing Tar and Felt ND Gray/Black Roofing Material ND
White Roofing Material (Membrane) ND Composite Non-Asbestos Content: 15% Cellulose
10% Synthetic Fibers 3% Glass Fibers
Sample Composite Homogeneity: Poor
Location: M-BUR-01B, Roofing Lab ID-Version‡: 17209640-1
Sample Layers Asbestos Content Brown Roofing Felt ND
Yellow Foam ND Brown Fibrous Material ND
Brown/Black Fibrous Material ND Black Roofing Tar and Felt ND
Gray/Black Roofing Material ND White Roofing Material (Membrane) ND
Composite Non-Asbestos Content: 25% Cellulose 5% Synthetic Fibers 2% Glass Fibers
Sample Composite Homogeneity: Poor
EMLab ID: 3523372, Page 2 of 43Eurofins Aerotech Built Environment Testing, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".
(800) 651-4802 www.eurofinsus.com/BuiltClient: Partner Engineering & Science, Inc. - Southwest C/O: Paul Anger Re: McClintock HS Roofing
Date of Sampling: 01-29-2024 Date of Receipt: 01-31-2024 Date of Report: 02-07-2024
ASBESTOS PLM REPORT
Location: M-BUR-01C, Roofing Lab ID-Version‡: 17209641-1
Sample Layers Asbestos Content Brown Fibrous Material ND
Brown/Black Fibrous Material ND Black Roofing Tar and Felt ND
Gray/Black Roofing Material ND White Roofing Material (Membrane) ND
Composite Non-Asbestos Content: 20% Cellulose 10% Synthetic Fibers < 1% Glass Fibers
Sample Composite Homogeneity: Poor
Location: M-BUR-02A, Roofing Lab ID-Version‡: 17209642-1
Sample Layers Asbestos Content Yellow Foam ND
Black Roofing Tar and Felt ND Gray Roofing Shingle ND
Composite Non-Asbestos Content: 15% Glass Fibers Sample Composite Homogeneity: Moderate
Location: M-BUR-02B, Roofing Lab ID-Version‡: 17209643-1
Sample Layers Asbestos Content Yellow Foam ND
Black Roofing Tar and Felt ND Gray Roofing Shingle ND
Composite Non-Asbestos Content: 15% Glass Fibers Sample Composite Homogeneity: Moderate
EMLab ID: 3523372, Page 3 of 43Eurofins Aerotech Built Environment Testing, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Partner Engineering & Science, Inc. - Southwest C/O: Paul Anger Re: McClintock HS Roofing
Date of Sampling: 01-29-2024 Date of Receipt: 01-31-2024 Date of Report: 02-07-2024
ASBESTOS PLM REPORT
Location: M-BUR-02C, Roofing Lab ID-Version‡: 17209644-1
Sample Layers Asbestos Content Yellow Foam ND
Black Roofing Tar and Felt ND Gray Roofing Shingle ND
Composite Non-Asbestos Content: 15% Glass Fibers Sample Composite Homogeneity: Moderate
Location: M-BUR-03A, Roofing Lab ID-Version‡: 17209645-1
Sample Layers Asbestos Content Brown Roofing Felt ND
Yellow Foam ND Black Roofing Tar and Felt ND
Gray Roofing Shingle ND Composite Non-Asbestos Content: 10% Cellulose
10% Glass Fibers Sample Composite Homogeneity: Poor
Location: M-BUR-03B, Roofing Lab ID-Version‡: 17209646-1
Sample Layers Asbestos Content Brown Roofing Felt ND
Yellow Foam ND Black Roofing Tar and Felt ND
Gray Roofing Shingle ND Composite Non-Asbestos Content: 10% Cellulose
10% Glass Fibers Sample Composite Homogeneity: Poor
EMLab ID: 3523372, Page 4 of 43Eurofins Aerotech Built Environment Testing, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Partner Engineering & Science, Inc. - Southwest C/O: Paul Anger Re: McClintock HS Roofing
Date of Sampling: 01-29-2024 Date of Receipt: 01-31-2024 Date of Report: 02-07-2024
ASBESTOS PLM REPORT
Location: M-BUR-03C, Roofing Lab ID-Version‡: 17209647-1
Sample Layers Asbestos Content Brown Roofing Felt ND
Yellow Foam ND Black Roofing Tar and Felt ND
Gray Roofing Shingle ND Composite Non-Asbestos Content: 10% Cellulose
10% Glass Fibers Sample Composite Homogeneity: Poor
EMLab ID: 3523372, Page 5 of 43Eurofins Aerotech Built Environment Testing, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Partner Engineering & Science, Inc. - Southwest C/O: Paul Anger Re: McClintock HS Roofing
Date of Sampling: 01-29-2024 Date of Receipt: 01-31-2024 Date of Report: 02-07-2024
ASBESTOS PLM REPORT
Location: M-BUR-04A, Roofing Lab ID-Version‡: 17209648-1
Sample Layers Asbestos Content Yellow Foam ND
Black Roofing Tar and Felt ND Gray Roofing Shingle ND
Composite Non-Asbestos Content: 10% Glass Fibers Sample Composite Homogeneity: Moderate
Location: M-BUR-04B, Roofing Lab ID-Version‡: 17209649-1
Sample Layers Asbestos Content Yellow Foam ND
Black Roofing Tar and Felt ND Gray Roofing Shingle ND
Composite Non-Asbestos Content: 10% Glass Fibers Sample Composite Homogeneity: Moderate
Location: M-BUR-04C, Roofing Lab ID-Version‡: 17209650-1
Sample Layers Asbestos Content Yellow Foam ND
Black Roofing Tar and Felt ND Gray Roofing Shingle ND
Composite Non-Asbestos Content: 10% Glass Fibers Sample Composite Homogeneity: Moderate
Location: M-BUR-05A, Roofing Lab ID-Version‡: 17209651-1
Sample Layers Asbestos Content Brown/Black Fibrous Material ND
Black Roofing Tar and Felt ND Gray/Black Roofing Material ND
White Roofing Material (Membrane) ND Composite Non-Asbestos Content: 20% Cellulose
5% Synthetic Fibers 3% Glass Fibers
Sample Composite Homogeneity: Poor
EMLab ID: 3523372, Page 6 of 43Eurofins Aerotech Built Environment Testing, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Partner Engineering & Science, Inc. - Southwest C/O: Paul Anger Re: McClintock HS Roofing
Date of Sampling: 01-29-2024 Date of Receipt: 01-31-2024 Date of Report: 02-07-2024
ASBESTOS PLM REPORT
Location: M-BUR-05B, Roofing Lab ID-Version‡: 17209652-1
Sample Layers Asbestos Content Brown/Black Fibrous Material ND
Black Roofing Tar and Felt ND Gray/Black Roofing Material ND
White Roofing Material (Membrane) ND Composite Non-Asbestos Content: 20% Cellulose
5% Synthetic Fibers 3% Glass Fibers
Sample Composite Homogeneity: Poor
Location: M-BUR-05C, Roofing Lab ID-Version‡: 17209653-1
Sample Layers Asbestos Content Brown Roofing Felt ND
Yellow Foam ND Brown/Black Fibrous Material ND
Black Roofing Tar and Felt ND Gray/Black Roofing Material ND
White Roofing Material (Membrane) ND Composite Non-Asbestos Content: 25% Cellulose
5% Synthetic Fibers 4% Glass Fibers
Sample Composite Homogeneity: Poor
Location: M-BUR-06A, Roofing Lab ID-Version‡: 17209654-1
Sample Layers Asbestos Content Brown/Black Fibrous Material ND
Black Roofing Tar and Felt ND Gray/Black Roofing Material ND
White Roofing Material (Membrane) ND Composite Non-Asbestos Content: 25% Cellulose
5% Synthetic Fibers 3% Glass Fibers
Sample Composite Homogeneity: Poor
EMLab ID: 3523372, Page 7 of 43Eurofins Aerotech Built Environment Testing, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Partner Engineering & Science, Inc. - Southwest C/O: Paul Anger Re: McClintock HS Roofing
Date of Sampling: 01-29-2024 Date of Receipt: 01-31-2024 Date of Report: 02-07-2024
ASBESTOS PLM REPORT
Location: M-BUR-06B, Roofing Lab ID-Version‡: 17209655-1
Sample Layers Asbestos Content Yellow Foam ND
Brown/Black Fibrous Material ND Black Roofing Tar and Felt ND
Gray/Black Roofing Material ND White Roofing Material (Membrane) ND
Composite Non-Asbestos Content: 25% Cellulose 5% Synthetic Fibers 3% Glass Fibers
Sample Composite Homogeneity: Poor
EMLab ID: 3523372, Page 8 of 43Eurofins Aerotech Built Environment Testing, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Partner Engineering & Science, Inc. - Southwest C/O: Paul Anger Re: McClintock HS Roofing
Date of Sampling: 01-29-2024 Date of Receipt: 01-31-2024 Date of Report: 02-07-2024
ASBESTOS PLM REPORT
Location: M-BUR-06C, Roofing Lab ID-Version‡: 17209656-1
Sample Layers Asbestos Content Brown/Black Fibrous Material ND
Black Roofing Tar and Felt ND Gray/Black Roofing Material ND
White Roofing Material (Membrane) ND Composite Non-Asbestos Content: 25% Cellulose
5% Synthetic Fibers 3% Glass Fibers
Sample Composite Homogeneity: Poor
Location: M-BUR-07A, Roofing Lab ID-Version‡: 17209657-1
Sample Layers Asbestos Content Brown/Black Fibrous Material ND
Black Roofing Tar and Felt ND Gray/Black Roofing Material ND
White Roofing Material (Membrane) ND Composite Non-Asbestos Content: 25% Cellulose
5% Glass Fibers 2% Synthetic Fibers
Sample Composite Homogeneity: Poor
Location: M-BUR-07B, Roofing Lab ID-Version‡: 17209658-1
Sample Layers Asbestos Content Brown/Black Fibrous Material ND
Black Roofing Tar and Felt ND Gray/Black Roofing Material ND
White Roofing Material (Membrane) ND Composite Non-Asbestos Content: 25% Cellulose
5% Glass Fibers 2% Synthetic Fibers
Sample Composite Homogeneity: Poor
EMLab ID: 3523372, Page 9 of 43Eurofins Aerotech Built Environment Testing, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Partner Engineering & Science, Inc. - Southwest C/O: Paul Anger Re: McClintock HS Roofing
Date of Sampling: 01-29-2024 Date of Receipt: 01-31-2024 Date of Report: 02-07-2024
ASBESTOS PLM REPORT
Location: M-BUR-07C, Roofing Lab ID-Version‡: 17209659-1
Sample Layers Asbestos Content Brown/Black Fibrous Material ND
Black Roofing Tar and Felt ND Gray/Black Roofing Material ND
White Roofing Material (Membrane) ND Composite Non-Asbestos Content: 25% Cellulose
5% Glass Fibers 2% Synthetic Fibers
Sample Composite Homogeneity: Poor
EMLab ID: 3523372, Page 10 of 43Eurofins Aerotech Built Environment Testing, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Partner Engineering & Science, Inc. - Southwest C/O: Paul Anger Re: McClintock HS Roofing
Date of Sampling: 01-29-2024 Date of Receipt: 01-31-2024 Date of Report: 02-07-2024
ASBESTOS PLM REPORT
Location: M-BUR-08A, Roofing Lab ID-Version‡: 17209660-1
Sample Layers Asbestos Content Brown Fibrous Material ND
Black Roofing Tar and Felt ND Gray Roofing Shingle ND
Composite Non-Asbestos Content: 10% Glass Fibers 5% Cellulose
Sample Composite Homogeneity: Moderate
Location: M-BUR-08B, Roofing Lab ID-Version‡: 17209661-1
Sample Layers Asbestos Content Brown Fibrous Material ND
Black Roofing Tar and Felt ND Gray Roofing Shingle ND
Composite Non-Asbestos Content: 10% Glass Fibers 5% Cellulose
Sample Composite Homogeneity: Moderate
Location: M-BUR-08C, Roofing Lab ID-Version‡: 17209662-1
Sample Layers Asbestos Content Brown Fibrous Material ND
Black Roofing Tar and Felt ND Gray Roofing Shingle ND
Composite Non-Asbestos Content: 10% Glass Fibers 5% Cellulose
Sample Composite Homogeneity: Moderate
Location: M-MAS-09A, Mastic Lab ID-Version‡: 17209663-1
Sample Layers Asbestos Content Black Mastic ND
Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Good
EMLab ID: 3523372, Page 11 of 43Eurofins Aerotech Built Environment Testing, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Partner Engineering & Science, Inc. - Southwest C/O: Paul Anger Re: McClintock HS Roofing
Date of Sampling: 01-29-2024 Date of Receipt: 01-31-2024 Date of Report: 02-07-2024
ASBESTOS PLM REPORT
Location: M-MAS-09B, Mastic Lab ID-Version‡: 17209664-1
Sample Layers Asbestos Content Black Mastic ND
Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Good
Location: M-MAS-09C, Mastic Lab ID-Version‡: 17209665-1
Sample Layers Asbestos Content Black Mastic ND
Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Good
Location: M-FLA-10A, Flashing Lab ID-Version‡: 17209666-1
Sample Layers Asbestos Content Black Roof Flashing ND
Silver Non-Fibrous Material ND Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Moderate
Location: M-FLA-10B, Flashing Lab ID-Version‡: 17209667-1
Sample Layers Asbestos Content Black Roof Flashing ND
Silver Non-Fibrous Material ND Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Moderate
EMLab ID: 3523372, Page 12 of 43Eurofins Aerotech Built Environment Testing, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Partner Engineering & Science, Inc. - Southwest C/O: Paul Anger Re: McClintock HS Roofing
Date of Sampling: 01-29-2024 Date of Receipt: 01-31-2024 Date of Report: 02-07-2024
ASBESTOS PLM REPORT
Location: M-FLA-10C, Flashing Lab ID-Version‡: 17209668-1
Sample Layers Asbestos Content Black Roof Flashing ND
Silver Non-Fibrous Material ND Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Moderate
Location: M-CTG-11A, Coating Lab ID-Version‡: 17209669-1
Sample Layers Asbestos Content White Coating ND
Sample Composite Homogeneity: Good
Location: M-CTG-11B, Coating Lab ID-Version‡: 17209670-1
Sample Layers Asbestos Content White Coating ND
Sample Composite Homogeneity: Good
Location: M-CTG-11C, Coating Lab ID-Version‡: 17209671-1
Sample Layers Asbestos Content White Coating ND
Sample Composite Homogeneity: Good
EMLab ID: 3523372, Page 13 of 43Eurofins Aerotech Built Environment Testing, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.
This is the start of the file's text. The full file is on GovTribe.