23-0412 1069 WEIGHT SCALE REPLACMENT - SOW.pdf
PDF 547 KB Posted
- Attached to
- Bldg 1069 Weight Scale Replacement (23-0412)
- Solicitation number
- N4008524R2571
About this file
This scope of work document outlines the replacement of an existing truck scale at Building 1069 on Camp Lejeune, North Carolina. The contractor will demolish the existing 70' x 11' steel deck truck scale and install a new heavy-duty 270,000lb capacity above ground scale to fit the existing foundation, including load cells, wiring, and calibration to meet all state certification requirements. The contractor must submit qualifications, installation drawings, product data, and a schedule for approval and provide on-site testing, calibration, and a five-year structural warranty upon completion. Responding contractors must be on the General Requirements cover page of the MACC contract for the ROICC Camp Lejeune area.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text
WEIGHT SCALE REPLACEMENT
AutoCAD SHX Text
PROJECT# 23M035CN
AutoCAD SHX Text
CONTRACT# 23-04120412
AutoCAD SHX Text
DWG: DANA WHITMORE
AutoCAD SHX Text
USMC CAMP LEJEUNE
AutoCAD SHX Text
BLDG #10691069
AutoCAD SHX Text
SHEET OF OF OF
AutoCAD SHX Text
TITLE PAGE
AutoCAD SHX Text T1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 23-0412 1069 WEIGHT SCALE REPLACEMENT SCOPE OF WORK: THE CONTRACTOR SHALL PROVIDE ALL MATERIAL, LABOR, EQUIPMENT AND THE CONTRACTOR SHALL PROVIDE ALL MATERIAL, LABOR, EQUIPMENT AND SUPERVISION REQUIRED TO ACCOMPLISH THE FOLLOWING. GENERAL DESCRIPTION: THIS SCOPE OF WORK IS TO BE ACCOMPLISHED AT BUILDING 1069. THIS SCOPE OF WORK IS TO BE ACCOMPLISHED AT BUILDING 1069. BUILDING 1069 IS LOCATED ON ABOARD, CAMP LEJEUNE, NORTH CAROLINA. CONTRACTOR TO REPLACE EXISTING BASE SCALE WITH A NEW SCALE MATCHING EXISTING HEIGHT AND FOUNDATION FOOTING, CONNECTION OF ALL WIRING. REPLACEMENT OF SCALE INDICATOR INSIDE OF BUILDING PER MANUFACTURES INSTRUCTIONS. NEW SCALE SHALL BE CALIBRATED AND ALL PERMITS, AND LICENSE REQUIRED FOR NORTH CAROLINA STATE D.O.T. CERTIFICATIONS. DETAILED REQUIREMENTS AND SPECIFICATIONS: THE CONTRACTOR SHALL TAKE HIS OWN FIELD : THE CONTRACTOR SHALL TAKE HIS OWN FIELD MEASUREMENTS IN DETERMINING REQUIRED MATERIALS AND COSTS FOR THE FOLLOWING. SPECIAL SCHEDULING AND ACCESS: ACCESS AND SCHEDULING TO THE WORK AREA SHALL BE ACCESS AND SCHEDULING TO THE WORK AREA SHALL BE ARRANGED THROUGH CONTRACTING OFFICER"S REPRESENTATIVE FOR THE OICC OFFICE AND THE TENANT OF THE BUILDING 1069. POINT OF CONTACT FOR ACCESS TO BUILDING 1069 IS ROBERT WARNER. MR. WARNER CAN BE REACHED AT OFFICE: 1-(910)-451-3551 OR CELL: 1-910-459-0982 NOTES: 1. THE MEASUREMENTS AND QUANTITIES FURNISHED HERE ARE FOR REFERENCE ONLY. THE THE MEASUREMENTS AND QUANTITIES FURNISHED HERE ARE FOR REFERENCE ONLY. THE CONTRACTOR IS RESPONSIBLE FOR ACTUAL FIELD VERIFICATION PRIOR TO BIDDING, ORDERING MATERIAL AND DURING EVERY STEP OF CONSTRUCTION FOR EXISTING SURFACES, DIMENSIONS AND CONDITIONS. 2. REPAIR, REFINISH OF AREAS DAMAGED OR DISTURBED BY NEW WORK TO BE PROVIDED REPAIR, REFINISH OF AREAS DAMAGED OR DISTURBED BY NEW WORK TO BE PROVIDED UNDER THIS CONTRACT. 3. CONTRACTOR MAY ONLY USE THE CAMP LEJEUNE SANITARY LANDFILL FOR THE DISPOSAL OF CONTRACTOR MAY ONLY USE THE CAMP LEJEUNE SANITARY LANDFILL FOR THE DISPOSAL OF ASBESTOS CONTAINING MATERIALS, BUILDING PRODUCTS WITH TIGHTLY ADHERED LEAD CONTAINING PAINT, NON-CONTAMINATED CLEAN DIRT AND CLEAN GRAVEL. THE HOURS OF OPERATIONS ARE 0730-1530 MONDAY- THURSDAY AND 0730-1430 ON FRIDAY. DELIVERY OF ACCEPTABLE MATERIALS (IDENTIFIED ABOVE) SHALL BE BY APPOINTMENT ONLY. APPOINTMENT MADE BY PHONE AT 1-910-457-5011 OR 1-910-451-2946. 4. ALL CONTAMINATED GENERATED MATERIAL SHALL BE WEIGHED THROUGH THE BASE LANDFILL ALL CONTAMINATED GENERATED MATERIAL SHALL BE WEIGHED THROUGH THE BASE LANDFILL SCALES BEFORE BEING REMOVED FROM THE BASE. CONTRACTOR UTILIZING THE BASE SCALE WILL REQUIRE CONTRACTING OFFICERS ASSISTED PER-REGISTRATION WITH THE LANDFILL MANAGER. 5. THE CONTRACTING OFFICER WILL REGISTER THE CONTRACT VIA E-MAIL, WITH THE BASE THE CONTRACTING OFFICER WILL REGISTER THE CONTRACT VIA E-MAIL, WITH THE BASE LANDFILL. ALL HAUL VEHICLES WILL MAINTAIN A SECURE VEHICLE PLACED AS A CONDITION TO UTILIZE THE SCALE. E-MAIL THE CONTRACTORS INFORMATION TO THE LANDFILL CLERK, INCLUDE THE NAME ON THE PRIME CONTRACTOR, CONTRACT NUMBER, JOB NAME / DESCRIPTION, COMPLETION DATE AND WHETHER OR NOT ANY ABOVE MATERIAL WILL BE DELIVERED TO THE LANDFILL. 6. PRIOR TO PERFORMING "HOT WORK" (WELDING, CUTTING, ECT.) OR OPERATING OTHER FLAME PRIOR TO PERFORMING "HOT WORK" (WELDING, CUTTING, ECT.) OR OPERATING OTHER FLAME -PRODUCING SPARK PRODUCING DEVICES, A WRITTEN PERMIT SHALL BE REQUESTED FROM THE FIRE DIVISION. CONTRACTORS ARE REQUIRED TO MEET ALL CRITERIA BEFORE A PERMIT IS ISSUED. THE CONTRACTOR WILL PROVIDE AT LEAST TWO (2) TWENTY (20) POUND 4A:20 BC RATED EXTINGUISHERS FOR NORMAL "HOT WORK". ALL EXTINGUISHERS SHALL BE CURRENT INSPECTION TAGGED, APPROVED SAFETY PIN AND TAMPER RESISTANT SEAL. IT IS ALSO MANDATORY TO HAVE A DESIGNATED FIRE WATCH FOR ANY "HOT WORK" DONE AT THIS ACTIVITY. THE FIRE WATCH SHALL BE TRAINED IN ACCORDANCE WITH NFPA 51B AND REMAIN ON SITE FOR A MINIMUM OF THIRTY (30) MINUTES AFTER WORK IS COMPLETED. 7. CONTRACTOR IS TO BE AWARE OF ALL RULES, REGULATION AND CODES REQUIRED FOR CONTRACTOR IS TO BE AWARE OF ALL RULES, REGULATION AND CODES REQUIRED FOR SUCCESSFUL COMPLETION OF PROJECT.
AutoCAD SHX Text SUBMITTALS: 1. CONTRACTOR SHALL MAKE ELECTRONIC COPIES OF ALL SUBMITTALS, INCLUDE CONTRACTOR SHALL MAKE ELECTRONIC COPIES OF ALL SUBMITTALS, INCLUDE THE APPROVED TRANSMITTAL SHEETS AND PROVIDE TWO (2) CD/DVD'S CONTAINING ALL SUBMITTALS FOR PROJECT. THE CD/DVD'S SHALL BE MARKED "COMPLETE SUBMITTAL PACKAGE - "23-0412 1069 WEIGHT SCALE REPLACEMENT" WITH CONTRACT # "N40085-23-B-0412" 2. AFTER AWARD: THE CONTRACTOR SHALL FURNISH THE CONTRACTING OFFICER, AFTER AWARD: THE CONTRACTOR SHALL FURNISH THE CONTRACTING OFFICER, MATERIAL, SPECIFICATIONS FOR SELECTION AND APPROVAL PRIOR TO THE ORDERING AND INSTALLATION OF SAID MATERIALS. 3. THE CONTRACTOR IS REQUIRED TO SUBMIT A SCHEDULE DETAILING WHEN THEY THE CONTRACTOR IS REQUIRED TO SUBMIT A SCHEDULE DETAILING WHEN THEY AND OR ANY SUBCONTRACTOR WILL BE WORKING. THE SCHEDULE MUST BE APPROVED BY GOVERNMENT BEFORE BEGINNING WORK. 4. THE CONTRACTOR SHALL SUBMIT TO THE CONTRACTING OFFICER, THE THE CONTRACTOR SHALL SUBMIT TO THE CONTRACTING OFFICER, THE MANUFACTURE'S PRODUCT SPECIFICATIONS, COMPLETE WITH TECHNICAL PRODUCTS DATA FOR ALL OF THE MATERIAL BEING USED IN THIS PROCESS. THE PRODUCT SPECIFICATION SHALL AS A MINIMUM, PROVIDE THE TECHNICAL DETAILS ON THE FOLLOWING ITEMS. 5. SUBMIT: SUBMIT: A. INSTALLATION DRAWINGS /SHOP DRAWINGS / AS BUILT DRAWINGS INSTALLATION DRAWINGS /SHOP DRAWINGS / AS BUILT DRAWINGS B. PRODUCT DATA PRODUCT DATA B.A. MANUFACTURES TECHNICAL DATA SHEET MANUFACTURES TECHNICAL DATA SHEET B.B. MATERIAL SAFETY DATA SHEETS (MADA) MATERIAL SAFETY DATA SHEETS (MADA) B.C. MAINTENANCE DATA MAINTENANCE DATA C. "COMPLETE SUBMITTAL PACKAGE CONTRACT #23M035CN" "COMPLETE SUBMITTAL PACKAGE CONTRACT #23M035CN" 6. QUALIFICATIONS: QUALIFICATIONS: 6.1. FABRICATOR QUALIFICATIONS: MINIMUM OF TEN YEARS DOCUMENTED FABRICATOR QUALIFICATIONS: MINIMUM OF TEN YEARS DOCUMENTED EXPERIENCE IN FABRICATING ABOVE GROUND SCALES SIMILAR IN SCOPE AND COMPLEXITY TO THIS PROJECT. 6.2. INSTALLER QUALIFICATION: MINIMUM OF FIVE YEARS DOCUMENTED INSTALLER QUALIFICATION: MINIMUM OF FIVE YEARS DOCUMENTED INSTALLATION EXPERIENCE FOR PROJECT SIMILAR IN SCOPE AND COMPLEXITY TO THIS PROJECT AND CURRENTLY
AutoCAD SHX Text
23-0412 1069 WEIGHT SCALE REPLACEMENT
AutoCAD SHX Text T1
AutoCAD SHX Text
TITLE PAGE
AutoCAD SHX Text A1
AutoCAD SHX Text
SPECIFICATION / LOCATION MAP
AutoCAD SHX Text A2
AutoCAD SHX Text
SITE PLAN
AutoCAD SHX Text A3
AutoCAD SHX Text
FOUNDATION PLAN
AutoCAD SHX Text A4
AutoCAD SHX Text
RAMP SECTION
AutoCAD SHX Text E1
ELECTRICAL
WALLACE CREEK
W
AL
LA
C
E C
R
EE
K R
D
ENDURANCE DR
ETA3 R
ANGE RD
PARACHUTE
TO
W
ER R
D
SANGIN RD
U
TILITIES W
AY
ISMT RD
WILSON BLVD RAMP
CONE W
AY
BST LOOP RD
IN
C
ID
EN
TA
L
LO
O
P R
D
W
IL
SO
N
BL
VD
R
AM
P
RT34
G R
EEN
W
AY TR
AIL
PT3
WC144
S635
SWC1J
S634
S983
SWC113
SWC143
S625
TP460
WC161
WC165
WC145
WC508
WC300
WC200
WC500
WC506WC504
WC178
WC177
WC100
WC160
WC159
WC124
WC125
WC510
WC148
WC501
WC140
WC146
S806
S870
S872
TP448
S1981
TP457
TP440
WC99
PT4
WC301
STP467
TP468
S894
PT3C
S871
PT5
PT6
TP454
TP456
CONT78
TP453
S893
WC503
SPT16
WC320
S869
WC135
WC130
WC115
WC110
WC120
WC105
TP464
WC320
WC512
TP466
WC204
WC200A
SWC165A
SWC145B
SWC165B
SWC145C
U
TILITIES W
AY 978
S983
AutoCAD SHX Text
WEIGHT SCALE REPLACEMENT
AutoCAD SHX Text
PROJECT# 23M035CN
AutoCAD SHX Text
CONTRACT# 23-04120412
AutoCAD SHX Text
DWG: DANA WHITMORE
AutoCAD SHX Text
USMC CAMP LEJEUNE
AutoCAD SHX Text
BLDG #10691069
AutoCAD SHX Text
SHEET OF OF OF
AutoCAD SHX Text
FLOOR PLAN
AutoCAD SHX Text A1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text 23-0412 1069 WEIGHT SCALE REPLACEMENT DETAILED REQUIREMENTS AND SPECIFICATIONS 1.) GENERAL REQUIREMENTS: GENERAL REQUIREMENTS: A. DEMO: DEMO: a.a. EXISTING TRUCK SCALE 70' x 11' ONLY EXISTING TRUCK SCALE 70' x 11' ONLY a.b. ALL METALS SHALL BE RECYCLABLE ALL METALS SHALL BE RECYCLABLE a.b.a. CONTRACTOR SHALL TRANSPORT ALL METAL TO THE RECYCLING FACILITY AT BLDG. CONTRACTOR SHALL TRANSPORT ALL METAL TO THE RECYCLING FACILITY AT BLDG. 978 POC MR. DENSON, MR. DENSON CAN BE REACHED AT 451-2037 a.b.b. METAL SHALL BE WEIGHTED AT THE LANDFILL PRIOR TO BEING TRANSPORTED TO METAL SHALL BE WEIGHTED AT THE LANDFILL PRIOR TO BEING TRANSPORTED TO T&P LOT S1002. B. INSTALL INSTALL a.a. PROVIDE NEW HEAVY-DUTY VERSION OF THE EXISTING SCALE PROVIDE NEW HEAVY-DUTY VERSION OF THE EXISTING SCALE a.a. 70' X 11' STEEL DECK TRUCK SCALE 270,00LBS CAPACITY 70' X 11' STEEL DECK TRUCK SCALE 270,00LBS CAPACITY a.b. ABOVE GROUND HEAVY DUTY TRUCK SCALE ABOVE GROUND HEAVY DUTY TRUCK SCALE a.c. TRUCK SCALE TO FIT EXISTING FOUNDATION TRUCK SCALE TO FIT EXISTING FOUNDATION a.d. SHALL MOUNT NEW SCALE WIRING AND ANALOG INTERFACE AS REQUIRED PER SHALL MOUNT NEW SCALE WIRING AND ANALOG INTERFACE AS REQUIRED PER MANUFACTURES INSTRUCTION a.e. INSTALL RISER PLATES TO MATCH EXISTING FOUNDATION INSTALL RISER PLATES TO MATCH EXISTING FOUNDATION a.f. PROVIDE NEW LOAD CELLS AND LOAD CELL STANDS PROVIDE NEW LOAD CELLS AND LOAD CELL STANDS a.g. PROVIDE ALL EQUIPMENT AND MANPOWER FOR A COMPLETE OPERATION INSTALLATION PROVIDE ALL EQUIPMENT AND MANPOWER FOR A COMPLETE OPERATION INSTALLATION OF A NEW HEAVY DUTY TRUCK SCALE a. CONTRACTOR SHALL PROVIDE: CONTRACTOR SHALL PROVIDE: a.a. ALL TESTING FOR PROPER OPERATION ALL TESTING FOR PROPER OPERATION a.b. CALIBRATION PER MANUFACTURES WRITTEN INSTRUCTIONS CALIBRATION PER MANUFACTURES WRITTEN INSTRUCTIONS a.c. MEET ALL N.C.D.O.T. DOCUMENTATION, PERMITS, CERTIFICATIONS MEET ALL N.C.D.O.T. DOCUMENTATION, PERMITS, CERTIFICATIONS a.d. PROVIDE WRITTEN STRUCTURAL FIVE(5) YEAR WARRANTYPROVIDE WRITTEN STRUCTURAL FIVE(5) YEAR WARRANTY
AutoCAD SHX Text
AutoCAD SHX Text A1
AutoCAD SHX Text
VICINITY MAP
AutoCAD SHX Text 1/128" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A1
AutoCAD SHX Text
LOCATION MAP
1/32" = 1'-0"
TRUCK SCALE
AutoCAD SHX Text
RAMP
AutoCAD SHX Text
RAMP
AutoCAD SHX Text
WEIGHT SCALE REPLACEMENT
AutoCAD SHX Text
PROJECT# 23M035CN
AutoCAD SHX Text
CONTRACT# 23-04120412
AutoCAD SHX Text
DWG: DANA WHITMORE
AutoCAD SHX Text
USMC CAMP LEJEUNE
AutoCAD SHX Text
BLDG #10691069
AutoCAD SHX Text
SHEET OF OF OF
AutoCAD SHX Text
SITE
AutoCAD SHX Text A2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
AutoCAD SHX Text A2
AutoCAD SHX Text
SITE PLAN
1/16" - 1'-0"
AutoCAD SHX Text
PROJECT# 23M035CN
AutoCAD SHX Text
CONTRACT# 23-04120412
AutoCAD SHX Text
DWG: DANA WHITMORE
AutoCAD SHX Text
USMC CAMP LEJEUNE
AutoCAD SHX Text
BLDG #10691069
AutoCAD SHX Text
SHEET OF OF OF
AutoCAD SHX Text
FLOOR PLAN
AutoCAD SHX Text A3
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text
FOUNDATION PLAN
AutoCAD SHX Text 3/32" - 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text
CONCRETE RAMP AND SLAB PLAN
AutoCAD SHX Text 3/32" - 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text
TRUCK SCALE BASE PLATE LOCATION PLAN
AutoCAD SHX Text 3/32" - 1'-0"
AutoCAD SHX Text
RAMP UP
AutoCAD SHX Text
RAMP DOWN
AutoCAD SHX Text
FLAT
AutoCAD SHX Text
8" THICK CONCRETE BASE SLAB
AutoCAD SHX Text
FLAT
AutoCAD SHX Text
RAMP DOWN
RAMP UP
AutoCAD SHX Text
PROJECT# 23M035CN
AutoCAD SHX Text
CONTRACT# 23-04120412
AutoCAD SHX Text
DWG: DANA WHITMORE
AutoCAD SHX Text
USMC CAMP LEJEUNE
AutoCAD SHX Text
BLDG #10691069
AutoCAD SHX Text
SHEET OF OF OF
AutoCAD SHX Text
SECTION PLAN
AutoCAD SHX Text A4
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BASE PLATE
AutoCAD SHX Text
AutoCAD SHX Text A4
AutoCAD SHX Text
RAMP SECTION
AutoCAD SHX Text 1/4" - 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A4
AutoCAD SHX Text
FOUNDATION SECTION
AutoCAD SHX Text 3/4" - 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A4
AutoCAD SHX Text
BASE PLAT DETAIL
3" - 1'-0"
TRUCK SCALE
AutoCAD SHX Text
RAMP
AutoCAD SHX Text
RAMP
AutoCAD SHX Text
WEIGHT SCALE REPLACEMENT
AutoCAD SHX Text
PROJECT# 23M035CN
AutoCAD SHX Text
CONTRACT# 23-04120412
AutoCAD SHX Text
DWG: DANA WHITMORE
AutoCAD SHX Text
USMC CAMP LEJEUNE
AutoCAD SHX Text
BLDG #10691069
AutoCAD SHX Text
SHEET OF OF OF
AutoCAD SHX Text
ELECTRICAL PLAN
AutoCAD SHX Text E1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E1
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text 1/16" - 1'-0"
NOTE: EXISTING UTILITY: PANEL: A FIRST DECK CIRCUIT: 18 20AMP SINGLE POLE 120V PANEL: SIEMENS 120/208V SINGLE PHASE
| Sheets and Views |
| 1069 WEIGHT SCALE REPLACMENT DWG-TITLES |
| 1069 WEIGHT SCALE REPLACMENT DWG-SPECIFICATIONS |
| 1069 WEIGHT SCALE REPLACMENT DWG-SITE PLAN |
| 1069 WEIGHT SCALE REPLACMENT DWG-FOUNDATION PLAN |
| 1069 WEIGHT SCALE REPLACMENT DWG-RAMP SECTION (2) |
| 1069 WEIGHT SCALE REPLACMENT DWG-ELECTRICAL |
File details come from the government source that posted it. Updated .