23-0412 1069 WEIGHT SCALE REPLACMENT - SOW.pdf

PDF 547 KB Posted

Attached to
Bldg 1069 Weight Scale Replacement (23-0412)
Solicitation number
N4008524R2571
Issued by

About this file

This scope of work document outlines the replacement of an existing truck scale at Building 1069 on Camp Lejeune, North Carolina. The contractor will demolish the existing 70' x 11' steel deck truck scale and install a new heavy-duty 270,000lb capacity above ground scale to fit the existing foundation, including load cells, wiring, and calibration to meet all state certification requirements. The contractor must submit qualifications, installation drawings, product data, and a schedule for approval and provide on-site testing, calibration, and a five-year structural warranty upon completion. Responding contractors must be on the General Requirements cover page of the MACC contract for the ROICC Camp Lejeune area.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AutoCAD SHX Text

WEIGHT SCALE REPLACEMENT

AutoCAD SHX Text

PROJECT# 23M035CN

AutoCAD SHX Text

CONTRACT# 23-04120412

AutoCAD SHX Text

DWG: DANA WHITMORE

AutoCAD SHX Text

USMC CAMP LEJEUNE

AutoCAD SHX Text

BLDG #10691069

AutoCAD SHX Text

SHEET OF OF OF

AutoCAD SHX Text

TITLE PAGE

AutoCAD SHX Text T1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 23-0412 1069 WEIGHT SCALE REPLACEMENT SCOPE OF WORK: THE CONTRACTOR SHALL PROVIDE ALL MATERIAL, LABOR, EQUIPMENT AND THE CONTRACTOR SHALL PROVIDE ALL MATERIAL, LABOR, EQUIPMENT AND SUPERVISION REQUIRED TO ACCOMPLISH THE FOLLOWING. GENERAL DESCRIPTION: THIS SCOPE OF WORK IS TO BE ACCOMPLISHED AT BUILDING 1069. THIS SCOPE OF WORK IS TO BE ACCOMPLISHED AT BUILDING 1069. BUILDING 1069 IS LOCATED ON ABOARD, CAMP LEJEUNE, NORTH CAROLINA. CONTRACTOR TO REPLACE EXISTING BASE SCALE WITH A NEW SCALE MATCHING EXISTING HEIGHT AND FOUNDATION FOOTING, CONNECTION OF ALL WIRING. REPLACEMENT OF SCALE INDICATOR INSIDE OF BUILDING PER MANUFACTURES INSTRUCTIONS. NEW SCALE SHALL BE CALIBRATED AND ALL PERMITS, AND LICENSE REQUIRED FOR NORTH CAROLINA STATE D.O.T. CERTIFICATIONS. DETAILED REQUIREMENTS AND SPECIFICATIONS: THE CONTRACTOR SHALL TAKE HIS OWN FIELD : THE CONTRACTOR SHALL TAKE HIS OWN FIELD MEASUREMENTS IN DETERMINING REQUIRED MATERIALS AND COSTS FOR THE FOLLOWING. SPECIAL SCHEDULING AND ACCESS: ACCESS AND SCHEDULING TO THE WORK AREA SHALL BE ACCESS AND SCHEDULING TO THE WORK AREA SHALL BE ARRANGED THROUGH CONTRACTING OFFICER"S REPRESENTATIVE FOR THE OICC OFFICE AND THE TENANT OF THE BUILDING 1069. POINT OF CONTACT FOR ACCESS TO BUILDING 1069 IS ROBERT WARNER. MR. WARNER CAN BE REACHED AT OFFICE: 1-(910)-451-3551 OR CELL: 1-910-459-0982 NOTES: 1. THE MEASUREMENTS AND QUANTITIES FURNISHED HERE ARE FOR REFERENCE ONLY. THE THE MEASUREMENTS AND QUANTITIES FURNISHED HERE ARE FOR REFERENCE ONLY. THE CONTRACTOR IS RESPONSIBLE FOR ACTUAL FIELD VERIFICATION PRIOR TO BIDDING, ORDERING MATERIAL AND DURING EVERY STEP OF CONSTRUCTION FOR EXISTING SURFACES, DIMENSIONS AND CONDITIONS. 2. REPAIR, REFINISH OF AREAS DAMAGED OR DISTURBED BY NEW WORK TO BE PROVIDED REPAIR, REFINISH OF AREAS DAMAGED OR DISTURBED BY NEW WORK TO BE PROVIDED UNDER THIS CONTRACT. 3. CONTRACTOR MAY ONLY USE THE CAMP LEJEUNE SANITARY LANDFILL FOR THE DISPOSAL OF CONTRACTOR MAY ONLY USE THE CAMP LEJEUNE SANITARY LANDFILL FOR THE DISPOSAL OF ASBESTOS CONTAINING MATERIALS, BUILDING PRODUCTS WITH TIGHTLY ADHERED LEAD CONTAINING PAINT, NON-CONTAMINATED CLEAN DIRT AND CLEAN GRAVEL. THE HOURS OF OPERATIONS ARE 0730-1530 MONDAY- THURSDAY AND 0730-1430 ON FRIDAY. DELIVERY OF ACCEPTABLE MATERIALS (IDENTIFIED ABOVE) SHALL BE BY APPOINTMENT ONLY. APPOINTMENT MADE BY PHONE AT 1-910-457-5011 OR 1-910-451-2946. 4. ALL CONTAMINATED GENERATED MATERIAL SHALL BE WEIGHED THROUGH THE BASE LANDFILL ALL CONTAMINATED GENERATED MATERIAL SHALL BE WEIGHED THROUGH THE BASE LANDFILL SCALES BEFORE BEING REMOVED FROM THE BASE. CONTRACTOR UTILIZING THE BASE SCALE WILL REQUIRE CONTRACTING OFFICERS ASSISTED PER-REGISTRATION WITH THE LANDFILL MANAGER. 5. THE CONTRACTING OFFICER WILL REGISTER THE CONTRACT VIA E-MAIL, WITH THE BASE THE CONTRACTING OFFICER WILL REGISTER THE CONTRACT VIA E-MAIL, WITH THE BASE LANDFILL. ALL HAUL VEHICLES WILL MAINTAIN A SECURE VEHICLE PLACED AS A CONDITION TO UTILIZE THE SCALE. E-MAIL THE CONTRACTORS INFORMATION TO THE LANDFILL CLERK, INCLUDE THE NAME ON THE PRIME CONTRACTOR, CONTRACT NUMBER, JOB NAME / DESCRIPTION, COMPLETION DATE AND WHETHER OR NOT ANY ABOVE MATERIAL WILL BE DELIVERED TO THE LANDFILL. 6. PRIOR TO PERFORMING "HOT WORK" (WELDING, CUTTING, ECT.) OR OPERATING OTHER FLAME PRIOR TO PERFORMING "HOT WORK" (WELDING, CUTTING, ECT.) OR OPERATING OTHER FLAME -PRODUCING SPARK PRODUCING DEVICES, A WRITTEN PERMIT SHALL BE REQUESTED FROM THE FIRE DIVISION. CONTRACTORS ARE REQUIRED TO MEET ALL CRITERIA BEFORE A PERMIT IS ISSUED. THE CONTRACTOR WILL PROVIDE AT LEAST TWO (2) TWENTY (20) POUND 4A:20 BC RATED EXTINGUISHERS FOR NORMAL "HOT WORK". ALL EXTINGUISHERS SHALL BE CURRENT INSPECTION TAGGED, APPROVED SAFETY PIN AND TAMPER RESISTANT SEAL. IT IS ALSO MANDATORY TO HAVE A DESIGNATED FIRE WATCH FOR ANY "HOT WORK" DONE AT THIS ACTIVITY. THE FIRE WATCH SHALL BE TRAINED IN ACCORDANCE WITH NFPA 51B AND REMAIN ON SITE FOR A MINIMUM OF THIRTY (30) MINUTES AFTER WORK IS COMPLETED. 7. CONTRACTOR IS TO BE AWARE OF ALL RULES, REGULATION AND CODES REQUIRED FOR CONTRACTOR IS TO BE AWARE OF ALL RULES, REGULATION AND CODES REQUIRED FOR SUCCESSFUL COMPLETION OF PROJECT.

AutoCAD SHX Text SUBMITTALS: 1. CONTRACTOR SHALL MAKE ELECTRONIC COPIES OF ALL SUBMITTALS, INCLUDE CONTRACTOR SHALL MAKE ELECTRONIC COPIES OF ALL SUBMITTALS, INCLUDE THE APPROVED TRANSMITTAL SHEETS AND PROVIDE TWO (2) CD/DVD'S CONTAINING ALL SUBMITTALS FOR PROJECT. THE CD/DVD'S SHALL BE MARKED "COMPLETE SUBMITTAL PACKAGE - "23-0412 1069 WEIGHT SCALE REPLACEMENT" WITH CONTRACT # "N40085-23-B-0412" 2. AFTER AWARD: THE CONTRACTOR SHALL FURNISH THE CONTRACTING OFFICER, AFTER AWARD: THE CONTRACTOR SHALL FURNISH THE CONTRACTING OFFICER, MATERIAL, SPECIFICATIONS FOR SELECTION AND APPROVAL PRIOR TO THE ORDERING AND INSTALLATION OF SAID MATERIALS. 3. THE CONTRACTOR IS REQUIRED TO SUBMIT A SCHEDULE DETAILING WHEN THEY THE CONTRACTOR IS REQUIRED TO SUBMIT A SCHEDULE DETAILING WHEN THEY AND OR ANY SUBCONTRACTOR WILL BE WORKING. THE SCHEDULE MUST BE APPROVED BY GOVERNMENT BEFORE BEGINNING WORK. 4. THE CONTRACTOR SHALL SUBMIT TO THE CONTRACTING OFFICER, THE THE CONTRACTOR SHALL SUBMIT TO THE CONTRACTING OFFICER, THE MANUFACTURE'S PRODUCT SPECIFICATIONS, COMPLETE WITH TECHNICAL PRODUCTS DATA FOR ALL OF THE MATERIAL BEING USED IN THIS PROCESS. THE PRODUCT SPECIFICATION SHALL AS A MINIMUM, PROVIDE THE TECHNICAL DETAILS ON THE FOLLOWING ITEMS. 5. SUBMIT: SUBMIT: A. INSTALLATION DRAWINGS /SHOP DRAWINGS / AS BUILT DRAWINGS INSTALLATION DRAWINGS /SHOP DRAWINGS / AS BUILT DRAWINGS B. PRODUCT DATA PRODUCT DATA B.A. MANUFACTURES TECHNICAL DATA SHEET MANUFACTURES TECHNICAL DATA SHEET B.B. MATERIAL SAFETY DATA SHEETS (MADA) MATERIAL SAFETY DATA SHEETS (MADA) B.C. MAINTENANCE DATA MAINTENANCE DATA C. "COMPLETE SUBMITTAL PACKAGE CONTRACT #23M035CN" "COMPLETE SUBMITTAL PACKAGE CONTRACT #23M035CN" 6. QUALIFICATIONS: QUALIFICATIONS: 6.1. FABRICATOR QUALIFICATIONS: MINIMUM OF TEN YEARS DOCUMENTED FABRICATOR QUALIFICATIONS: MINIMUM OF TEN YEARS DOCUMENTED EXPERIENCE IN FABRICATING ABOVE GROUND SCALES SIMILAR IN SCOPE AND COMPLEXITY TO THIS PROJECT. 6.2. INSTALLER QUALIFICATION: MINIMUM OF FIVE YEARS DOCUMENTED INSTALLER QUALIFICATION: MINIMUM OF FIVE YEARS DOCUMENTED INSTALLATION EXPERIENCE FOR PROJECT SIMILAR IN SCOPE AND COMPLEXITY TO THIS PROJECT AND CURRENTLY

AutoCAD SHX Text

23-0412 1069 WEIGHT SCALE REPLACEMENT

AutoCAD SHX Text T1

AutoCAD SHX Text

TITLE PAGE

AutoCAD SHX Text A1

AutoCAD SHX Text

SPECIFICATION / LOCATION MAP

AutoCAD SHX Text A2

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text A3

AutoCAD SHX Text

FOUNDATION PLAN

AutoCAD SHX Text A4

AutoCAD SHX Text

RAMP SECTION

AutoCAD SHX Text E1

ELECTRICAL

WALLACE CREEK

W

AL

LA

C

E C

R

EE

K R

D

ENDURANCE DR

ETA3 R

ANGE RD

PARACHUTE

TO

W

ER R

D

SANGIN RD

U

TILITIES W

AY

ISMT RD

WILSON BLVD RAMP

CONE W

AY

BST LOOP RD

IN

C

ID

EN

TA

L

LO

O

P R

D

W

IL

SO

N

BL

VD

R

AM

P

RT34

G R

EEN

W

AY TR

AIL

PT3

WC144

S635

SWC1J

S634

S983

SWC113

SWC143

S625

TP460

WC161

WC165

WC145

WC508

WC300

WC200

WC500

WC506WC504

WC178

WC177

WC100

WC160

WC159

WC124

WC125

WC510

WC148

WC501

WC140

WC146

S806

S870

S872

TP448

S1981

TP457

TP440

WC99

PT4

WC301

STP467

TP468

S894

PT3C

S871

PT5

PT6

TP454

TP456

CONT78

TP453

S893

WC503

SPT16

WC320

S869

WC135

WC130

WC115

WC110

WC120

WC105

TP464

WC320

WC512

TP466

WC204

WC200A

SWC165A

SWC145B

SWC165B

SWC145C

U

TILITIES W

AY 978

S983

AutoCAD SHX Text

WEIGHT SCALE REPLACEMENT

AutoCAD SHX Text

PROJECT# 23M035CN

AutoCAD SHX Text

CONTRACT# 23-04120412

AutoCAD SHX Text

DWG: DANA WHITMORE

AutoCAD SHX Text

USMC CAMP LEJEUNE

AutoCAD SHX Text

BLDG #10691069

AutoCAD SHX Text

SHEET OF OF OF

AutoCAD SHX Text

FLOOR PLAN

AutoCAD SHX Text A1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text 23-0412 1069 WEIGHT SCALE REPLACEMENT DETAILED REQUIREMENTS AND SPECIFICATIONS 1.) GENERAL REQUIREMENTS: GENERAL REQUIREMENTS: A. DEMO: DEMO: a.a. EXISTING TRUCK SCALE 70' x 11' ONLY EXISTING TRUCK SCALE 70' x 11' ONLY a.b. ALL METALS SHALL BE RECYCLABLE ALL METALS SHALL BE RECYCLABLE a.b.a. CONTRACTOR SHALL TRANSPORT ALL METAL TO THE RECYCLING FACILITY AT BLDG. CONTRACTOR SHALL TRANSPORT ALL METAL TO THE RECYCLING FACILITY AT BLDG. 978 POC MR. DENSON, MR. DENSON CAN BE REACHED AT 451-2037 a.b.b. METAL SHALL BE WEIGHTED AT THE LANDFILL PRIOR TO BEING TRANSPORTED TO METAL SHALL BE WEIGHTED AT THE LANDFILL PRIOR TO BEING TRANSPORTED TO T&P LOT S1002. B. INSTALL INSTALL a.a. PROVIDE NEW HEAVY-DUTY VERSION OF THE EXISTING SCALE PROVIDE NEW HEAVY-DUTY VERSION OF THE EXISTING SCALE a.a. 70' X 11' STEEL DECK TRUCK SCALE 270,00LBS CAPACITY 70' X 11' STEEL DECK TRUCK SCALE 270,00LBS CAPACITY a.b. ABOVE GROUND HEAVY DUTY TRUCK SCALE ABOVE GROUND HEAVY DUTY TRUCK SCALE a.c. TRUCK SCALE TO FIT EXISTING FOUNDATION TRUCK SCALE TO FIT EXISTING FOUNDATION a.d. SHALL MOUNT NEW SCALE WIRING AND ANALOG INTERFACE AS REQUIRED PER SHALL MOUNT NEW SCALE WIRING AND ANALOG INTERFACE AS REQUIRED PER MANUFACTURES INSTRUCTION a.e. INSTALL RISER PLATES TO MATCH EXISTING FOUNDATION INSTALL RISER PLATES TO MATCH EXISTING FOUNDATION a.f. PROVIDE NEW LOAD CELLS AND LOAD CELL STANDS PROVIDE NEW LOAD CELLS AND LOAD CELL STANDS a.g. PROVIDE ALL EQUIPMENT AND MANPOWER FOR A COMPLETE OPERATION INSTALLATION PROVIDE ALL EQUIPMENT AND MANPOWER FOR A COMPLETE OPERATION INSTALLATION OF A NEW HEAVY DUTY TRUCK SCALE a. CONTRACTOR SHALL PROVIDE: CONTRACTOR SHALL PROVIDE: a.a. ALL TESTING FOR PROPER OPERATION ALL TESTING FOR PROPER OPERATION a.b. CALIBRATION PER MANUFACTURES WRITTEN INSTRUCTIONS CALIBRATION PER MANUFACTURES WRITTEN INSTRUCTIONS a.c. MEET ALL N.C.D.O.T. DOCUMENTATION, PERMITS, CERTIFICATIONS MEET ALL N.C.D.O.T. DOCUMENTATION, PERMITS, CERTIFICATIONS a.d. PROVIDE WRITTEN STRUCTURAL FIVE(5) YEAR WARRANTYPROVIDE WRITTEN STRUCTURAL FIVE(5) YEAR WARRANTY

AutoCAD SHX Text

AutoCAD SHX Text A1

AutoCAD SHX Text

VICINITY MAP

AutoCAD SHX Text 1/128" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text A1

AutoCAD SHX Text

LOCATION MAP

1/32" = 1'-0"

TRUCK SCALE

AutoCAD SHX Text

RAMP

AutoCAD SHX Text

RAMP

AutoCAD SHX Text

WEIGHT SCALE REPLACEMENT

AutoCAD SHX Text

PROJECT# 23M035CN

AutoCAD SHX Text

CONTRACT# 23-04120412

AutoCAD SHX Text

DWG: DANA WHITMORE

AutoCAD SHX Text

USMC CAMP LEJEUNE

AutoCAD SHX Text

BLDG #10691069

AutoCAD SHX Text

SHEET OF OF OF

AutoCAD SHX Text

SITE

AutoCAD SHX Text A2

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PLAN

AutoCAD SHX Text

AutoCAD SHX Text A2

AutoCAD SHX Text

SITE PLAN

1/16" - 1'-0"

AutoCAD SHX Text

PROJECT# 23M035CN

AutoCAD SHX Text

CONTRACT# 23-04120412

AutoCAD SHX Text

DWG: DANA WHITMORE

AutoCAD SHX Text

USMC CAMP LEJEUNE

AutoCAD SHX Text

BLDG #10691069

AutoCAD SHX Text

SHEET OF OF OF

AutoCAD SHX Text

FLOOR PLAN

AutoCAD SHX Text A3

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text

AutoCAD SHX Text A3

AutoCAD SHX Text

FOUNDATION PLAN

AutoCAD SHX Text 3/32" - 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text A3

AutoCAD SHX Text

CONCRETE RAMP AND SLAB PLAN

AutoCAD SHX Text 3/32" - 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text A3

AutoCAD SHX Text

TRUCK SCALE BASE PLATE LOCATION PLAN

AutoCAD SHX Text 3/32" - 1'-0"

AutoCAD SHX Text

RAMP UP

AutoCAD SHX Text

RAMP DOWN

AutoCAD SHX Text

FLAT

AutoCAD SHX Text

8" THICK CONCRETE BASE SLAB

AutoCAD SHX Text

FLAT

AutoCAD SHX Text

RAMP DOWN

RAMP UP

AutoCAD SHX Text

PROJECT# 23M035CN

AutoCAD SHX Text

CONTRACT# 23-04120412

AutoCAD SHX Text

DWG: DANA WHITMORE

AutoCAD SHX Text

USMC CAMP LEJEUNE

AutoCAD SHX Text

BLDG #10691069

AutoCAD SHX Text

SHEET OF OF OF

AutoCAD SHX Text

SECTION PLAN

AutoCAD SHX Text A4

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

BASE PLATE

AutoCAD SHX Text

AutoCAD SHX Text A4

AutoCAD SHX Text

RAMP SECTION

AutoCAD SHX Text 1/4" - 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text A4

AutoCAD SHX Text

FOUNDATION SECTION

AutoCAD SHX Text 3/4" - 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text A4

AutoCAD SHX Text

BASE PLAT DETAIL

3" - 1'-0"

TRUCK SCALE

AutoCAD SHX Text

RAMP

AutoCAD SHX Text

RAMP

AutoCAD SHX Text

WEIGHT SCALE REPLACEMENT

AutoCAD SHX Text

PROJECT# 23M035CN

AutoCAD SHX Text

CONTRACT# 23-04120412

AutoCAD SHX Text

DWG: DANA WHITMORE

AutoCAD SHX Text

USMC CAMP LEJEUNE

AutoCAD SHX Text

BLDG #10691069

AutoCAD SHX Text

SHEET OF OF OF

AutoCAD SHX Text

ELECTRICAL PLAN

AutoCAD SHX Text E1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text E1

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text 1/16" - 1'-0"

NOTE: EXISTING UTILITY: PANEL: A FIRST DECK CIRCUIT: 18 20AMP SINGLE POLE 120V PANEL: SIEMENS 120/208V SINGLE PHASE

Sheets and Views
1069 WEIGHT SCALE REPLACMENT DWG-TITLES
1069 WEIGHT SCALE REPLACMENT DWG-SPECIFICATIONS
1069 WEIGHT SCALE REPLACMENT DWG-SITE PLAN
1069 WEIGHT SCALE REPLACMENT DWG-FOUNDATION PLAN
1069 WEIGHT SCALE REPLACMENT DWG-RAMP SECTION (2)
1069 WEIGHT SCALE REPLACMENT DWG-ELECTRICAL