2277516_QAIRQMT_REPORT.pdf

PDF 81 KB Posted

Attached to
NSN 4710002926302NZ F100 Tube Assembly, Metal - Spares Buy
Solicitation number
FA812125Q0010
Issued by

About this file

This is an AFMC Form 807 detailing Quality Assurance Provisions and Special Inspection Requirements for a contract related to NSN 4710002926302NZ. The form specifies that inspection and acceptance will occur at the source location per DFARS 246.402, and requires Higher Level Contract Quality Requirements under AS 9100 standard.

The document indicates this is for a previous source (not a new vendor), with no quality pre-award survey required. It includes an Ozone Depleting Substances statement confirming the contract does not require use of Class I ODS. The technical authority is William A Brady from AFLCMC/LPSEA2, with oversight from Item Manager Barbara A Bland and Equipment Specialist James Warnecke. The form was generated on October 28, 2024, though the technical authority signature date is July 24, 2017.

View the file

Other files

File Type Posted
Surplus Material Evaluation Form.pdf PDF
FA812125Q0010.pdf PDF
4710002926302NZ_QUALRQMT.pdf PDF
2277511_SMW_REPORT.pdf PDF
4022727_TRNSPDATA_REPORT.pdf PDF
4022725_PKGRQMT_REPORT.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RECOMMENDED QUALITY ASSURANCE PROVISIONS

AND SPECIAL INSPECTION REQUIREMENTS

1. PR / MIPR NUMBER

2. NATIONAL STOCK NUMBER

4710002926302NZ

3. POINT OF INSPECTION

SOURCE DESTINATION

X

SEE DFARS 246.402

4. POINT OF ACCEPTANCE

SOURCE DESTINATION

X

5. ITEM MANAGER / PHONE

Bland, Barbara A / 405-734-9816

6. EQUIPMENT SPEC / PHONE

Warnecke, James / 405-734-0415

7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS

CERTIFICATE OF CONFORMANCE

FAR 52.246-15

CONTRACT RESPONSIBILITY

FOR INSPECTION

FAR 52.246-1

STANDARD INSPECTION

FAR 52.246-2,-3,-4,-5 OR -6

AS APPLICABLE TO CONTRACT

X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS

AS 9100

COMMERCIAL ITEM INSPECTION

FAR 52.212-4

OTHER (Describe in Block 8)

8. REMARKS

8a. OZONE DEPLETING SUBSTANCES (ODS)

X STATEMENT

"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN

ONLY BE MET BY THE USE OF A CLASS I ODS."

WAIVER (SEE AF FARS 5323)

NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.

9. QUALITY PRE-AWARD SURVEY

YES NEW SOURCE

X PREVIOUS SOURCEX NO

AFMC PARTICIPATION

RECOMMENDED

10. CODES

A. I&A

B. CQR

G

11. SIGNATURE OF TECHNICAL AUTHORITY

Brady, William A

ORGANIZATION / SYMBOL

AFLCMC / LPSEA2

PHONE

405-734-8715 / 334-8715

DATE

24 JUL 2017

Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 28 Oct 2024

File details come from the government source that posted it. Updated .