225 Pitkin Street Electrical Drawing 03.10.26.pdf
PDF 583 KB Posted
- Attached to
- Day Program Renovation
- Solicitation number
- 37726
- Issued by
- Hartford County, Connecticut
About this file
Summary of 225 Pitkin Street Electrical Drawing
This electrical drawing document, prepared by Capital Studio Architects LLC for Options Unlimited, Inc., provides the detailed electrical plan for the general renovations of a day program facility located at 225 Pitkin Street, East Hartford, Connecticut (Project No. 26035, Sheet E-A1.1). The project involves converting former college classrooms and a kitchen area into an adult day program space, with electrical work including lighting fixture installation, fire alarm system expansion and modification, emergency lighting, exit signage, and associated wiring and outlets throughout multiple rooms designated as daycare rooms, offices, conference areas, storage spaces, and restrooms. The drawing specifies that all wiring shall be concealed where physically possible, with exposed circuiting installed in pipe and neatly routed parallel to or at right angles to building structure lines. Fire alarm modifications require new devices matching building standards, including initiation and annunciation device wiring, input/output zone cards, power supplies, batteries, and complete system programming. The project scope includes LED emergency lighting units (Lithonia ELM2 LED HO SD) and LED exit signs (Isolite RL-EM-G-U-WH-SD rated at 3 watts), with fire alarm pull stations mounted at 42 inches above finished floor. The electrical drawing was dated March 10, 2026, coordinating with architectural drawings dated April 22, 2026.
No pricing terms, contract duration, set-asides, or award information is contained within this electrical drawing document, as it serves as a technical specification and design reference for the solicitation rather than a procurement terms document. Contractors responding to the bid solicitation (ITB 37726, with bids due July 31, 2026 at 1:00 p.m. EDT) should use this drawing in conjunction with other project documentation, including the scope of work and specifications, to develop accurate cost proposals and construction schedules.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
project no.
scale checked drawn
1379 MAIN STREET EAST HARTFORD CT. 06108
CAPITAL
STUDIO
a r c h i t e c t s L L C office: 860.289.3262 capitalstudio.net no.
General Renovations for the
OPTIONS
UNLIMITED
225 Pitkin Street, East Hartford, Connecticut date description revisions
Ge ne ral Re no va tio ns fo r P
RO
JEC
T N
AM
E, Cit y, CT
C
SA
Pr oje ct
XX
-XX
: s he et
5 E
-A ll date
Fax: 860.895.8386 290 Burnside Avenue, East Hartford, CT 06108 Tel: 860.895.8385
#24024
PN: 26035
GENERAL DRAWING NOTES:
E-1.1
ELECTRICAL
PLAN
F F F
F
FIRE ALARM SYMBOL LIST
F
LIGHTING FIXTURE SCHEDULE
AutoCAD SHX Text FLOOR PLAN Scale: 1/4" = 1'-0"
AutoCAD SHX Text 25-48
AutoCAD SHX Text 3/10/26
AutoCAD SHX Text
KEY PLAN
AutoCAD SHX Text
PROJECT AREA
AutoCAD SHX Text
BBO
AutoCAD SHX Text ALL WIRING SHALL BE RUN CONCEALED WHERE PHYSICALLY POSSIBLE. IN AREAS WITHOUT CEILINGS, EXPOSED CIRCUITING SHALL BE INSTALLED IN PIPE AND WIRE AND NEATLY ROUTED PARALLEL TO OR AT RIGHT ANGLES TO BUILDING STRUCTURE/LINES. FIRE ALARM SCOPE IS AN EXPANSION/MODIFICATION OF AN EXISTING SYSTEM. NEW DEVICES ARE TO MATCH BUILDING STANDARD. PROVIDE NEW INITIATION AND ANNUNCIATION DEVICE WIRING, INPUT/OUTPUT ZONE CARDS, POWER SUPPLIES, BATTERIES, PROGRAMMING AND ALL APPURTENANCES AS NEEDED FOR A COMPLETE WORKING SYSTEM.
AutoCAD SHX Text H.
AutoCAD SHX Text REFER TO ARCHITECTURAL DRAWINGS FOR THE EXACT LOCATION AND MOUNTING HEIGHTS OF ALL LIGHTING FIXTURES, SWITCHES, DEVICES AND OUTLETS. JUNCTION OR OUTLET BOXES SHALL BE INSTALLED SO AS TO ALLOW ACCESS TO COVER. PROVIDE ARCHITECT APPROVED ACCESS DOORS OR PLATES AS REQUIRED IN AREAS WHERE UNOBSTRUCTED ACCESS TO BOX OR OUTLET IS NOT POSSIBLE. PRIOR TO ORDERING FIXTURES, COORDINATE WITH ARCHITECTURAL DRAWINGS AND SPECIFICATIONS. IF DISCREPANCIES EXIST BETWEEN ARCHITECTURAL AND ENGINEERING INFORMATION OBTAIN CLARIFICATION PRIOR TO PROCEEDING. MULTIPLE SWITCHES SHOWN IN SAME LOCATION SHALL BE GANGED TOGETHER WITH A COMMON FACEPLATE. LIGHTING FIXTURES UTILIZING ELECTRONIC BALLASTS SHALL BE PROVIDED WITH A DEDICATED NEUTRAL. PROVIDE DEDICATED NEUTRAL CONDUCTORS FOR EACH BRANCH CIRCUIT.
AutoCAD SHX Text E.
AutoCAD SHX Text F.
AutoCAD SHX Text D.
AutoCAD SHX Text C.
AutoCAD SHX Text A.
AutoCAD SHX Text B.
AutoCAD SHX Text G.
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
BBO
AutoCAD SHX Text
KITCHENETTE
AutoCAD SHX Text
DAYCARE ROOM 1
AutoCAD SHX Text
DAYCARE ROOM 2
AutoCAD SHX Text
DAYCARE ROOM 3
AutoCAD SHX Text
DAYCARE ROOM 4
AutoCAD SHX Text
OFFICE 1
AutoCAD SHX Text
CONF.
AutoCAD SHX Text M
AutoCAD SHX Text W
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
WOMENS
AutoCAD SHX Text
MENS
AutoCAD SHX Text
RECEPTION
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text V.M.
AutoCAD SHX Text
REF.
AutoCAD SHX Text
OFFICE 2
AutoCAD SHX Text
OFFICE 3
AutoCAD SHX Text
OFFICE 4
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
DEMO EXST. DOOR AND
AutoCAD SHX Text
WALL BACK TO CEILING
AutoCAD SHX Text
PATCH FLOOR
AutoCAD SHX Text ADDRESSABLE FIRE ALARM PULL STATION, SINGLE ACTION WITH CLEAR PRE-ALARM COVER, MOUNT AT 42" AFF.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MODEL NUMBER
AutoCAD SHX Text
WATTAGE
AutoCAD SHX Text
LED EMERGENCY LIGHTING UNIT
AutoCAD SHX Text
WITH REMOTE WET LOCATION HEADS WHERE INDICATED
AutoCAD SHX Text
AutoCAD SHX Text
LITHONIA # ELM2 LED HO SD
AutoCAD SHX Text
LED EXIT SIGN
AutoCAD SHX Text
3 WATTS
AutoCAD SHX Text
ISOLITE # RL-EM-G-U-WH-SD
AutoCAD SHX Text
NEW TO MATCH EXISTING BUILDING STANDARD