Summary of 225 Pitkin Street Electrical Drawing

This electrical drawing document, prepared by Capital Studio Architects LLC for Options Unlimited, Inc., provides the detailed electrical plan for the general renovations of a day program facility located at 225 Pitkin Street, East Hartford, Connecticut (Project No. 26035, Sheet E-A1.1). The project involves converting former college classrooms and a kitchen area into an adult day program space, with electrical work including lighting fixture installation, fire alarm system expansion and modification, emergency lighting, exit signage, and associated wiring and outlets throughout multiple rooms designated as daycare rooms, offices, conference areas, storage spaces, and restrooms. The drawing specifies that all wiring shall be concealed where physically possible, with exposed circuiting installed in pipe and neatly routed parallel to or at right angles to building structure lines. Fire alarm modifications require new devices matching building standards, including initiation and annunciation device wiring, input/output zone cards, power supplies, batteries, and complete system programming. The project scope includes LED emergency lighting units (Lithonia ELM2 LED HO SD) and LED exit signs (Isolite RL-EM-G-U-WH-SD rated at 3 watts), with fire alarm pull stations mounted at 42 inches above finished floor. The electrical drawing was dated March 10, 2026, coordinating with architectural drawings dated April 22, 2026.

No pricing terms, contract duration, set-asides, or award information is contained within this electrical drawing document, as it serves as a technical specification and design reference for the solicitation rather than a procurement terms document. Contractors responding to the bid solicitation (ITB 37726, with bids due July 31, 2026 at 1:00 p.m. EDT) should use this drawing in conjunction with other project documentation, including the scope of work and specifications, to develop accurate cost proposals and construction schedules.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

project no.

scale checked drawn

1379 MAIN STREET EAST HARTFORD CT. 06108

CAPITAL

STUDIO

a r c h i t e c t s L L C office: 860.289.3262 capitalstudio.net no.

General Renovations for the

OPTIONS

UNLIMITED

225 Pitkin Street, East Hartford, Connecticut date description revisions

Ge ne ral Re no va tio ns fo r P

RO

JEC

T N

AM

E, Cit y, CT

C

SA

Pr oje ct

XX

-XX

: s he et

5 E

-A ll date

Fax: 860.895.8386 290 Burnside Avenue, East Hartford, CT 06108 Tel: 860.895.8385

#24024

PN: 26035

GENERAL DRAWING NOTES:

E-1.1

ELECTRICAL

PLAN

F F F

F

FIRE ALARM SYMBOL LIST

F

LIGHTING FIXTURE SCHEDULE

AutoCAD SHX Text FLOOR PLAN Scale: 1/4" = 1'-0"

AutoCAD SHX Text 25-48

AutoCAD SHX Text 3/10/26

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text

PROJECT AREA

AutoCAD SHX Text

BBO

AutoCAD SHX Text ALL WIRING SHALL BE RUN CONCEALED WHERE PHYSICALLY POSSIBLE. IN AREAS WITHOUT CEILINGS, EXPOSED CIRCUITING SHALL BE INSTALLED IN PIPE AND WIRE AND NEATLY ROUTED PARALLEL TO OR AT RIGHT ANGLES TO BUILDING STRUCTURE/LINES. FIRE ALARM SCOPE IS AN EXPANSION/MODIFICATION OF AN EXISTING SYSTEM. NEW DEVICES ARE TO MATCH BUILDING STANDARD. PROVIDE NEW INITIATION AND ANNUNCIATION DEVICE WIRING, INPUT/OUTPUT ZONE CARDS, POWER SUPPLIES, BATTERIES, PROGRAMMING AND ALL APPURTENANCES AS NEEDED FOR A COMPLETE WORKING SYSTEM.

AutoCAD SHX Text H.

AutoCAD SHX Text REFER TO ARCHITECTURAL DRAWINGS FOR THE EXACT LOCATION AND MOUNTING HEIGHTS OF ALL LIGHTING FIXTURES, SWITCHES, DEVICES AND OUTLETS. JUNCTION OR OUTLET BOXES SHALL BE INSTALLED SO AS TO ALLOW ACCESS TO COVER. PROVIDE ARCHITECT APPROVED ACCESS DOORS OR PLATES AS REQUIRED IN AREAS WHERE UNOBSTRUCTED ACCESS TO BOX OR OUTLET IS NOT POSSIBLE. PRIOR TO ORDERING FIXTURES, COORDINATE WITH ARCHITECTURAL DRAWINGS AND SPECIFICATIONS. IF DISCREPANCIES EXIST BETWEEN ARCHITECTURAL AND ENGINEERING INFORMATION OBTAIN CLARIFICATION PRIOR TO PROCEEDING. MULTIPLE SWITCHES SHOWN IN SAME LOCATION SHALL BE GANGED TOGETHER WITH A COMMON FACEPLATE. LIGHTING FIXTURES UTILIZING ELECTRONIC BALLASTS SHALL BE PROVIDED WITH A DEDICATED NEUTRAL. PROVIDE DEDICATED NEUTRAL CONDUCTORS FOR EACH BRANCH CIRCUIT.

AutoCAD SHX Text E.

AutoCAD SHX Text F.

AutoCAD SHX Text D.

AutoCAD SHX Text C.

AutoCAD SHX Text A.

AutoCAD SHX Text B.

AutoCAD SHX Text G.

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

BBO

AutoCAD SHX Text

KITCHENETTE

AutoCAD SHX Text

DAYCARE ROOM 1

AutoCAD SHX Text

DAYCARE ROOM 2

AutoCAD SHX Text

DAYCARE ROOM 3

AutoCAD SHX Text

DAYCARE ROOM 4

AutoCAD SHX Text

OFFICE 1

AutoCAD SHX Text

CONF.

AutoCAD SHX Text M

AutoCAD SHX Text W

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

WOMENS

AutoCAD SHX Text

MENS

AutoCAD SHX Text

RECEPTION

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text V.M.

AutoCAD SHX Text

REF.

AutoCAD SHX Text

OFFICE 2

AutoCAD SHX Text

OFFICE 3

AutoCAD SHX Text

OFFICE 4

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

DEMO EXST. DOOR AND

AutoCAD SHX Text

WALL BACK TO CEILING

AutoCAD SHX Text

PATCH FLOOR

AutoCAD SHX Text ADDRESSABLE FIRE ALARM PULL STATION, SINGLE ACTION WITH CLEAR PRE-ALARM COVER, MOUNT AT 42" AFF.

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

TYPE

AutoCAD SHX Text

MODEL NUMBER

AutoCAD SHX Text

WATTAGE

AutoCAD SHX Text

LED EMERGENCY LIGHTING UNIT

AutoCAD SHX Text

WITH REMOTE WET LOCATION HEADS WHERE INDICATED

AutoCAD SHX Text

AutoCAD SHX Text

LITHONIA # ELM2 LED HO SD

AutoCAD SHX Text

LED EXIT SIGN

AutoCAD SHX Text

3 WATTS

AutoCAD SHX Text

ISOLITE # RL-EM-G-U-WH-SD

AutoCAD SHX Text

NEW TO MATCH EXISTING BUILDING STANDARD