223121 Drawings 22074 5132 Sunnyside RD SE Architectural Set-11.29.2022.pdf
PDF 1 MB Posted
- Solicitation number
- S-KS0043-00005339
- Issued by
- Marion County, Oregon
About this file
This document contains the drawings and specifications for the Bid No. 223121 Scattered Sites - Siding, Window, & Doors Replacement Project located in Marion County and the City of Salem, Oregon. The project scope includes replacing the exterior siding, windows, and doors at a single-family residential property. The drawings provide details on the new cementitious siding, vinyl windows, and wood/fiberglass entry doors to be installed. The project is being managed by the Salem Housing Authority. No bid due date, response timeline, or contract term is provided in the document.
The document does not contain pricing information, set-asides, incumbent contractor details, or funding sources. It focuses solely on the technical specifications and drawings for the construction work required. The document indicates the existing conditions will be surveyed and a percentage of the building materials will be replaced, with the remainder being repaired and left in place.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AERIAL VIEWVICINITY MAPDESIGN TEAM SHEET INDEX
TOC
A0.0
SHA SCATTERED SITE PROJECTS
5132 SUNNYSIDE ROAD SE
SIDING REPLACEMENT
SALEM, OREGON
SHA SCATTERED
SITES PROJECTS
SHEET
DRAWN:
REVISIONS:
JOB NO.:
DATE:
2022.0074
DEC 5, 2022
In the event conflicts are discovered between the original signed and sealed documents prepared by the Architects and/or their Consultants, and any copy of the documents transmitted by mail, fax, electronically or otherwise, the original signed and sealed documents shall govern.
ARCHITECTURE
C O M M U N I T Y 1100 Liberty Street SE Suite 200 Salem, OR 97302 P: 503.581.4114 www.accoac.com
5132 SUNNYSIDE ROAD SE
SALEM, OREGON 97301
COVER SHEET
rrothweiler@accoac.com
ATTN: RICHARD ROTHWEILER, AIA
FAX 503-581-3655
PH. 503-581-4114
SALEM, OREGON 97302
1100 LIBERTY ST NE
AC + CO ARCHITECTURE | COMMUNITY
ARCHITECT
OWNER
SALEM HOUSING AUTHORITY
360 CHURCH ST, SE
SALEM, OREGON 97301
PH: 503.588.6459
FAX: 503.587.4800
CONTACT: NICOLE UTZ
nutz@cityofsalem.net
ABBREVIATIONS
(REFER TO CONSULTANT DRAWINGS FOR ADDITIONAL ABBREVIATIONS)
AB ANCHOR BOLT
ABV ABOVE
A/C AIR CONDITIONING
AC ASPHALTIC CONCRETE
ACOUST ACOUSTIC
AD AREA DRAIN
ADA AMERICANS W/ DISABILITIES ACT
ADD ADDITIONAL
ADJ ADJUST (ABLE)
A/E ARCHITECT / ENGINEER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISH GRADE
AGG AGGREGATE
ALT ALTERNATE
ALUM ALUMINUM
ANCH ANCHOR
ANOD ANODIZED
APPROX APPROXIMATELY
ARCH ARCHITECT(URAL)
ASB ASBESTOS
ASPH ASPHALT
ASST ASSISTANT
ASSY ASSEMBLY
ASTM AMERICAN SOCIETY FOR
TESTING & MATERIALS
AUTO AUTOMATIC
AVG AVERAGE
BD BOARD
BFF BELOW FINISH FLOOR
BFG BELOW FINISH GRADE
BIT BITUMINOUS
BLW BELOW
BLDG BUILDING
BLKG BLOCKING
BM BENCH MARK, BEAM
B/O BOTTOM OF
BOS BOTTOM OF STEEL
BOT BOTTOM
BRKT BRACKET
BSMT BASEMENT
B/U BUILT-UP
BUR BUILT-UP ROOFING
MACH MACHINE
MAN MANUAL
MAINT MAINTANENCE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MACHINE BOLT
MBR MEMBER
MC MEDICINE CABINET
MED MEDIUM
MEMB MEMBRANE
MECH MECHANICAL
MFGD MANUFACTURED
MFR MANUFACTURER
MH MANHOLE
MIRR MIRROR
MIN MINIMUM
MISC MISCELLANEOUS
MLP METAL LATH & PLASTER
MO MASONRY OPENING
MOD MODULE
MOIST MOISTURE
MS METAL SCREEN
MTD MOUNTED
MTL METAL
MUL MULLION
N NORTH
NA NOT APPLICABLE
NAT NATURAL
NE NORTHEAST
NIC, (NIC) NOT IN CONTRACT
NO. NUMBER
NOM NOMINAL
NRC NOISE REDUCTION
COEFFICIENT
NTS NOT TO SCALE
NW NORTHWEST
O&M OPERATION & MAINTENANCE
OBS OBSCURE
OC ON CENTER
OCC OCCUPANT, OCCUPANCY
OD OUTSIDE DIAMETER,
OVERFLOW DRAIN
OF OUTSIDE FACE
OFCI OWNER FURNISHED -
CONTRACTOR INSTALLED
OFF OFFICE
OH OVERHEAD
OHG OVERHANG
OPG OPENING
OPP OPPOSITE
OPT OPTIONAL
ORIG ORIGINAL
OSB ORIENTED-STRAND BOARD
E EAST
(E) EXISTING
EA EACH
EC EDGE OF CURB
EG EDGE GUARD
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR
EMERG EMERGENCY
ENGR ENGINEER
ENCL ENCLOSURE
ENTR ENTRANCE
EP ELECTRICAL PANEL
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP B EXPANSION BOLT
EXP JT EXPANSION JOINT
EXT EXTERIOR
FA FIRE ALARM
FB FLAT BAR
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH, FINISHED
FIN FL FINISHED FLOOR
FL FLOOR
FLAM FLAMMABLE
FLUOR FLUORESCENT
FDN FOUNDATION
FOB FACE OF BRICK
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOS FACE OF STUD
FOW FACE OF WALL
FP FIREPROOF
FRMG FRAMING
FRP FIBERGLAS-REINFORCED PANEL
FS FLOOR SINK
FT FOOT, FEET
FTG FOOTING
FURR FURRING
FUT FUTURE
GA GAGE, GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERAL
GFCI GROUND-FAULT
CIRCUIT INTERRUPTER
GI GALVANIZED IRON
GL GLASS, GLAZING
GLB GLU-LAM BEAM
GRD GRADE
GRND GROUND
GWB GYPSUM WALL BOARD
GYP GYPSUM
HB HOSE BIBB
HC HOLLOW CORE
HD HEAD
HDW HARDWARE
HDR HEADER
HGT HEIGHT
HLDN HOLD DOWN
HM HOLLOW METAL
HO HOLD-OPEN
HORIZ HORIZONTAL
HR HOUR
HTG HEATING
HVAC HEATING-VENTILATING-
AIR CONDITIONING
HW HOT WATER
HWH HOT WATER HEATER
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IN INCH
INCL INCLUDE (D), INCLUDING
INFO INFORMATION
INSTR INSTRUCTION (S)
INSUL INSULATE (D), INSULATION
INT INTERIOR
INV INVERT
JAN JANITOR
J-BOX JUNCTION BOX
JST JOIST
JT JOINT
KD KILN-DRIED
KIT KITCHEN
KP KICK PLATE
KO KNOCK OUT
L LENGTH
LAB LABORATORY
LAM LAMINATE(D)
LAV LAVATORY
LB POUND
LBR LUMBER
LF LINEAL FEET
LH LEFT HAND
LIQ LIQUID
LKR LOCKER
LNDSCP LANDSCAPE
LT LIGHT, LEFT
LVL LAMINATED-VENEER LUMBER
LVR LOUVER
LVT LUXURY-VINYL TILE
CAB CABINET
CANTIL CANTILEVER
CB CATCH BASIN
CEM CEMENT
CER CERAMIC
CF/CI CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
CG CORNER GAURD
CHKBD CHALKBOARD
CI CAST IRON
CJ CONTROL JOINT
℄ CENTER LINE
CLG CEILING
CLR CLEAR, CLEARANCE
CMU CONCRETE MASONRY UNIT
CNTR COUNTER
CO CLEANOUT
COL COLUMN
CONC CONCRETE
COND CONDITION
CONN CONNECT, CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS, CONTINUE
CONTR CONTRACTOR
COR CORNER
CORR CORRIDOR
CPT CARPET
CSI CONSTRUCTION
SPECIFICATIONS INSTITUTE
CTR CENTER
CTSK COUNTERSINK, COUNTERSUNK
CW COLD WATER
CY CUBIC YARD
DBL DOUBLE
DEG DEGREES
DEMO DEMOLITION
DET DETAIL
DF DRINKING FOUNTAIN
D FIR DOUGLAS FIR
DH DOUBLE HUNG
DIAG DIAGONAL
DIA DIAMETER
DIM DIMENSION
DISP DISPENSER
DIV DIVIDE, DIVIDED, DIVISION
DN DOWN
DOD DOOR OPENING DIMENSION
DR DOOR
DS DOWNSPOUT
DSP DRY STANDPIPE
DTL DETAIL
DW DISHWASHER
DWG DRAWING
DWR DRAWER
PA PUBLIC ADDRESS
PARTN PARTITION
PASS PASSENGER
PAV PAVING
PC PIECE, PRECAST
PCF POUNDS PER CUBIC FOOT
PERF PERFORATED
PH PHASE
PJ PANEL JOINT
P/L PROPERTY LINE
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTIC
PLAT PLATFORM
PLBG PLUMBING
PLF POUNDS PER LINEAL FOOT
PLSTR PLASTER
PLYWD PLYWOOD
POLYISO POLYISOCYANURATE
PORT PORTABLE
PNL PANEL
PNTD PAINTED
PR PAIR
PREFAB PREFABRICATED
PRKG PARKING
PROJ PROJECT, PROJECTOR,
PROJECTION
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESERVATIVE-TREATED
PTD PAPER TOWEL DISPENSER
PTD/R PAPER TOWEL DISP & RECEPT
PTN PARTITION
PTR PAPER TOWEL RECEPTACLE
PUB PUBLIC
PVMT PAVEMENT
PVC POLYVINYL CHLORIDE
PWD PLYWOOD
PWR POWER
QT QUARRY TILE
R RADIUS, RISER
RA RETURN AIR
RD ROOF DRAIN
RECEP RECEPTION, RECEPTACLE
REF REFERENCE
REFL REFLECTED
REFR REFRIGERATOR
REINF REINFORCE, REINFORCEMENT
REM REMOVE, REMOVABLE
REPL REPLACE (D) (MENT)
REQD REQUIRED
RES RESERVE (D)
RESIL RESILIENT
REV REVERSE, REVISE (D), REVISION
RD ROOF DRAIN
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RT RIGHT
RV ROOF VENT
RWD REDWOOD
RWL RAIN WATER LEADER
S SOUTH
S4S SURFACED 4 SIDES
SA SUPPLY AIR
SAF SELF-ADHERING FLASHING
SALV SALVAGE
SAM SELF-ADHERING MEMBRANE
SAN SANITARY
SC SOLID CORE
SCD SEAT COVER DISPENSER
SCH SCHEDULE
SCR SCREW
SD SOAP DISPENSER
SE SOUTHEAST
SEC SECRETARY
SECT SECTION
SEP SEPARATE, SEPARATION
SERV SERVICE
SF SQUARE FOOT
SH SINGLE-HUNG, SHELF, SHELVES
SHR SHOWER
SHT SHEET
SHTG SHEATHING
SIM SIMILAR
SM SHEET METAL
SK SINK
SND SANITARY NAPKIN DISPENSER
SNR SANITARY NAPKIN RECEPTACLE
SOH SAME AT OPPOSITE HAND
SPEC SPECIFICATION, SPECIFIED
SPKR SPEAKER
SPL SPECIAL
SQ SQUARE
SS STAINLESS STEEL
STA STATION
ST STREET
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURE, STRUCTURAL
SUPV SUPERVISION
SUSP SUSPENDED
SV SHEET-VINYL
SW SOUTHWEST
SYM SYMMETRICAL
SYS SYSTEM
T TREAD
TB TACKBOARD
T&G TONGUE & GROOVE
TBD TO BE DETERMINED
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPERED, TEMPERATURE
TERM TERMINAL
TERR TERRAZZO
THK THICK (NESS) (ENED)
THRM THERMAL
THRU THROUGH
TJ TOOLED JOINT
TLT TOILET
TPD TOILET PAPER DISPENSER
T/O TOP OF
TOB TOP OF BEAM
TOC TOP OF CONCRETE,
TOP OF CURB
TOJ TOP OF JOIST
TOL TOLERANCE
TOM TOP OF MASONRY
TOP TOP OF PAVING
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPAER DISPENSER
TRANS TRANSFORMER
TREAT TREATMENT
TS TUBE STEEL
TV TELEVISION
TYP TYPICAL
UG UNDERGROUND
UL UNDERWRITERS LABORATORY
UNFIN UNFINISHED
UON UNLESS OTHERWISE NOTED
UR URINAL
UTIL UTILITY
VAR VARNISH
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VIF VERIFY IN FIELD
VERT VERTICAL
VEST VESTIBULE
VG VERTICAL GRAIN
VIN VINYL SHEET
VNR VENEER
VOL VOLUME
VT VINYL TILE
VTR VENT THROUGH ROOF
W WEST, WIDE, WIDTH
WC WATER CLOSET
WD WOOD
WDW WINDOW
WH WATER HEATER
(WO) WHERE OCCURS
W/O WITHOUT
WP WATERPROOF(ING)
WR WEATHER RESISTANT
WRB WEATHER RESISTANT BARRIER
WS WEATHERSTRIPPING
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE FABRIC
NOTES 1. WITH THE EXCEPTION OF "NO." (NUMBER), ABBREVIATIONS ARE TYPICALLY USED WITHOUT THE PERIOD (.). ABBREVIATIONS MAY ALSO APPEAR WITH THE PERIOD.
EXAMPLE: "PT" (PRESERVATIVE-TREATED) MAY ALSO APPEAR AS "P.T.".
2. AN "S" MAY BE ADDED TO AN ABBREVIATION TO INDICATE PLURAL, OR MULTIPLE OCCURRENCES.
GENERAL NOTES
GENERAL NOTES APPLY TO ALL DRAWINGS
DIMENSIONS ARE TO EXISTING FACE OF WALL, FACE OF NEW FRAMING,
AND FACE OF EXISTING CONCRETE UNLESS NOTED OTHERWISE.
DRAWINGS ARE DIAGRAMMATIC ONLY AND SHOULD NOT BE SCALED.
LARGE-SCALE DETAILS TAKE PRECEDENCE OVER SMALLER-SCALED
DETAILS.
DIMENSIONS OF EXISTING CONDITIONS ARE APPROXIMATE AND
INTENDED FOR ESTIMATING PURPOSES ONLY. CONTRACTOR SHALL BE
RESPONSIBLE TO FIELD VERIFY ALL DIMENSIONS PRIOR TO ACTUAL
CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF ANY
QUESTIONABLE DIMENSIONS PRIOR TO PROCEEDING WITH AREA OF
WORK IN QUESTION.
ALL INFORMATION ON EXISTING CONDITIONS SHOWN IN THE
DOCUMENTS IS GIVEN AS THE BEST PRESENT KNOWLEDGE, BUT
WITHOUT GUARANTEE OF ACCURACY.
1.
2.
3.
4.
5.
6.
ALL DETAILS SHOWN ARE TYPICAL UNLESS NOTED OTHERWISE. ANY
DETAIL SHOWN OF ONE AREA OR CONDITION IS APPLICABLE TO ALL
AREAS AND SIMILAR CONDITIONS.
NOT ALL BUILDING ELEMENTS MAY BE SHOWN IN THE DRAWINGS. IT IS
CONTRACTOR'S RESPONSIBILITY TO IDENTIFY ALL PROJECT-RELATED
BUILDING ELEMENTS, NOTIFY THE ARCHITECT OF ANY THAT HAVE NOT
BEEN IDENTIFIED IN THE DRAWINGS, AND PROCEED WITH THE WORK
ON THESE ELEMENTS ONLY UPON WRITTEN INSTRUCTIONS FROM THE
ARCHITECT.
EXISTING AND NEWLY CONSTRUCTED BUILDING SURFACES,
MATERIALS AND COMPONENTS TO BE PROTECTED AT ALL TIMES
DURING CONSTRUCTION.
7.
8.
9.
"AS REQUIRED" MEANS AS REQUIRED BY THESE DOCUMENTS,
APPLICABLE BUILDING CODES AND ORDINANCES, AND/OR THE
ARCHITECT.
CONTRACTOR SHALL PROVIDE A COMPLETE, WEATHER-TIGHT
PROJECT WITH ALL MATERIALS, PRODUCTS, EQUIPMENT AND SYSTEMS
FULLY AND ACCURATELY INSTALLED AS REQUIRED BY THESE
DOCUMENTS AND IN ACCORDANCE WITH BEST INDUSTRY PRACTICES
AND MANUFACTURER'S STATED RECOMMENDATIONS AND
INSTRUCTIONS.
THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN,
IF AT ALL, IN AN APPROXIMATE WAY ONLY AND HAVE NOT BEEN
INDEPENDENTLY VERIFIED BY OWNER OR ITS REPRESENTATIVES. THE
CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL
EXISTING UTILITIES BEFORE COMMENCING WORK, AND AGREES TO BE
FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE
OCCASIONED BY FAILURE TO EXACTLY LOCATE AND PRESERVE ANY
AND ALL UTILITIES.
SCOPE OF WORK INCLUDES:
10.
11.
12.
13.
i. NEW EXTERIOR SIDING, WINDOWS AND DOORS.
PROJECT
ARCHITECTURAL
A0.0 TITLE SHEET
A3.0 EXTERIOR ELEVATIONS AND DETAILS
A3.1 NEW WALL SECTIONS
A8.0 DOORS, WINDOWS, AND DETAILS
PROJECT
SUITE 200
AutoCAD SHX Text O
AutoCAD SHX Text
SALEM, OREGON
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text T
AutoCAD SHX Text D
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text
RICHARD S. ROTHWEILER
AutoCAD SHX Text
SHA SCATTERED
SITES PROJECTS
SHEET
DRAWN:
REVISIONS:
JOB NO.:
DATE:
2022.0074
SEPT 20, 2022
In the event conflicts are discovered between the original signed and sealed documents prepared by the Architects and/or their Consultants, and any copy of the documents transmitted by mail, fax, electronically or otherwise, the original signed and sealed documents shall govern.
ARCHITECTURE
C O M M U N I T Y 1100 Liberty Street SE Suite 200 Salem, OR 97302 P: 503.581.4114 www.accoac.com
5132 SUNNYSIDE ROAD SE
SALEM, OREGON 97301
TOC
A3.0
REFERENCE NOTES - EXTERIOR ELEVATIONS:
9 TYPICAL SIDING RENOVATION COMPONENTS:
· EXISTING SIDING AND TRIM TO BE REMOVED
· EXISTING WEATHER BARRIER TO BE REMOVED
· EXISTING WOOD SHEATHING TO REMAIN UNLESS NOTED TO BE REMOVED
·· SURVEY EXPOSED SHEATHING FOR WATER OR OTHER DAMAGE
·· BASE BID-REMOVE 20% OF SHEATHING
· INSTALL NEW PLYWOOD SHEATHING AS REQUIRED TO REPLACE PLYWOOD SHEATHING REMOVED
· INSTALL NEW PLYWOOD SHEATHING IF NONE EXISTS, TO MATCH THICKNESS
· INSTALL NEW INFILTRATION BARRIER OVER PLYWOOD SIDING.
· INSTALL NEW FLEXIBLE FLASHING AT ALL OPENING PENETRATIONS
· INSTALL NEW FLASHING AS REQUIRED
· INSTALL NEW 1x FURRING STRIPS VERTICALLY AT 16" OC AND/OR AS REQUIRED TO ANCHOR ALL
FURRING TO EXISTING STUDS FOR RAINSCREEN CONSTRUCTION.
· INSTALL NEW CEMENTITIOUS SIDING AND TRIM, PAINT, PROVIDE CEMENTITIOUS PANELS AND
BATTENS IN ALL GABLES
EXISTING WINDOW TO BE REMOVED, PREP ROUGH OPENING AS REQUIRED, PROVIDE NEW VINYL
NAIL-FIN WINDOW WITH NEW TRIM AND FLASHING, PAINT. REFER TO DETAILS SHEET A8.010
EXISTING GAS METER TO REMAIN11
EXISTING HOSE BIB TO REMAIN, PROVIDE NEW WOOD TRIM BLOCK, PAINT12
EXISTING ELECTRICAL METER BASE TO REMAIN, PROVIDE NEW CEMENTITIOUS TRIM13
EXISTING CHIMNEY TO REMAIN, SEAL15
EXISTING CT CAN TO REMAIN, REMOVE TRIM, PROVIDE NEW TRIM BLOCK, PAINT16
EXISTING LIGHT TO BE REMOVED, PROVIDE NEW LED LIGHT FIXTURE AND TRIM TO MATCH
EXISITING, PAINT IF REQUIRED
17 EXISTING DRYER EXHAUST TO BE REMOVED AND REPLACED WITH NEW VENT
EXISTING ROOF RIDGE TO REMAIN2
EXISTING SHEET METAL ROOF VENT TO REMAIN3
EXISTING SHEET METAL LOWER ROOF VENT TO REMAIN4
EXISTING KITCHEN AND/OR BATH VENT THRU ROOF TO REMAIN5
EXISTING PLUMBING VENT THRU ROOF JACK/BOOT FLASHING TO REMAIN6
EXISTING CONTINUOUS GUTTER TO REMAIN, PROVIDE NEW SECTIONS IF FASCIA IS REPLACED
DUE TO DRY-ROT, PAINT7
EXISTING DOWNSPOUT TO BE REMOVED, PROVIDE NEW DOWNSPOUT8
(NOT ALL NOTES ARE
REFERENCED ON EVERY SHEET)
NEW VINYL SLIDING PATIO DOOR, REFER TO DOOR SCHEDULE, PROVIDE NEW TRIM, PAINT18
EXISTING CAST METAL NUMBERS TO BE REMOVED, PROVIDE AND INSTALL NEW NUMBERS TO
MATCH EXISTING
EXISTING DOOR TO BE REMOVED, PROVIDE NEW DOOR, REFER TO SHEET A8.0, PAINT20
EXISTING FASCIA TO REMAIN, PAINT, REVIEW FASCIA FOR DRY-ROT, PROVIDE IN BASE BID
20% REPLACEMENT FASCIA, PAINT21
EXISTING COLUMN TO REMAIN PROVIDE NEW TRIM AND HEAD FLASHING, PAINT22
EXISTING GARAGE DOOR TO REMAIN, PAINT23
EXISTING GATE AND POST TO REMAIN24
EXISTING ROOF COMPONENTS TO REMAIN
EXISTING LINE-SET TO REMAIN, PROVIDE NEW TRIM BLOCKS AT WALL PENETRATION25
EXISTING FOUNDATION VENTS TO REMAIN26
NEW 5/4x10 TRIM BOARD AND FLASHING, PAINT27
GENERAL NOTES APPLY TO ALL DRAWINGS.
DIMENSIONS ARE TO EXISTING FACE OF WALL, FACE OF NEW FRAMING, AND FACE OF
EXISTING CONCRETE UNLESS NOTED OTHERWISE.
DRAWINGS ARE DIAGRAMMATIC ONLY AND SHOULD NOT BE SCALED. NOTIFY
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR QUESTIONABLE DIMENSIONS
PRIOR TO PROCEEDING WITH AREA OF QUESTIONABLE WORK.
FOR EXTERIOR ENVELOPE NEW MATERIALS AND REPAIR/RENOVATION, REFER TO
REFERENCE NOTES.
FOR ALL UNITS IN THE SCOPE OF WORK, PROVIDE REPAIR OF EXISTING GYPSUM
WALLBOARD PRIOR TO NEW PAINT.
1.
2.
3.
4.
5.
GENERAL NOTES:
SCALE:3
EXTERIOR ELEVATION - EAST
1/8"=1'-0"
SCALE:1
EXTERIOR ELEVATION - WEST
1/8"=1'-0"
SCALE:4
EXTERIOR ELEVATION - NORTH
1/8"=1'-0"
SCALE:2
EXTERIOR ELEVATION - SOUTH
1/8"=1'-0"
A3.1
A3.1
A3.1
A3.1
EXISTING 5 8" PLYWOOD SHEATHING
EXISTING ASPHALT SHINGLES
NEW SELF-ADHERING FLASHING; LAP
OVER SHEATHING AND FASCIA
EXISTING FASCIA AND SUB-FASCIA,
REFER TO ELEVATION NOTES FOR
REPLACEMENT IF REQUIRED
2"
6"
EXISTING 30 LB FELT UNDERLAYMENT
NEW DOWNSPOUT
NEW ALUM FLASHING
4"
NEW GUTTER
EXISTING PRE-MANUFACTURED TRUSSED
TO REMAIN
1"
FIN. FLR.
0'-0"
T.O. PLATE
9'-0"
FIELD VERIFY
8 2320
FIN. FLR.
0'-0"
T.O. PLATE
9'-0"
FIELD VERIFY
21 9
OPEN
THRU
1316 1110
FIN. FLR.
0'-0"
T.O. PLATE
9'-0"
FIN. FLR.
0'-0"
T.O. PLATE
9'-0"
10 1010
OPEN
THRU
DOOR FRAME DETAILS (A8.0)
NOMINAL
SIZENO. TYPE MAT'L GLASS TYPE MAT'L GLASS H J S
HDWR.
GROUP LABEL REMARKS
DOOR SCHEDULE - 2022.0074
ALL DOORS 13
4" THICK UNLESS OTHERWISE NOTED
5132B 6'-0"x7'-0" C VNYL TEMP EXST VNYL - - - - - - -
5132A 3'-0"x7'-0" A FBGL TEMP EXST WD - 5 5 SIM 13 1 - -
A
C
4 4 6
9 99
22 22
SCALE:5
ROOF EAVE AND GUTTER
3"=1'-0" 2274-A30-05
AutoCAD SHX Text O
AutoCAD SHX Text
SALEM, OREGON
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text T
AutoCAD SHX Text D
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text
RICHARD S. ROTHWEILER
A3.1
SHA SCATTERED
SITES PROJECTS
SHEET
DRAWN:
REVISIONS:
JOB NO.:
DATE:
2022.0074
SEPT 20, 2022
In the event conflicts are discovered between the original signed and sealed documents prepared by the Architects and/or their Consultants, and any copy of the documents transmitted by mail, fax, electronically or otherwise, the original signed and sealed documents shall govern.
ARCHITECTURE
C O M M U N I T Y 1100 Liberty Street SE Suite 200 Salem, OR 97302 P: 503.581.4114 www.accoac.com
5132 SUNNYSIDE ROAD SE
SALEM, OREGON 97301
NEW WALL SECTIONS
SCALE:1
WALL SECTION
3/4" = 1'-0" SCALE:2
WALL SECTION AT WINDOWS
3/4" = 1'-0" SCALE:3
WALL SECTION AT RAKE END
3/4" = 1'-0" SCALE:4
WALL SECTION AT WINDOWS AT RAKE END
3/4" = 1'-0"
T.O. PLATE
9'-0"
FIN. FLR.
0'-0"
EXISTING CONCRETE FLOOR SLAB AND
2'-0" RIGID INSULATION TO REMAIN
NEW DOWNSPOUT
EXISTING CONCRETE FOOTING TO REMAIN
NEW CONTINUOUS METAL DRIP FLASHING,
PAINT
EXISTING CONCRETE FLOOR SLAB AND
2'-0" RIGID INSULATION TO REMAIN
NEW DOWNSPOUT
EXISTING CONCRETE FOOTING TO REMAIN
NEW CONTINUOUS METAL DRIP FLASHING,
PAINT
NEW WALL SYSTEM
EXISTING ROOF SYSTEM
NEW VINYL NAIL-FIN WINDOW
EXISTING CONCRETE FLOOR SLAB AND
2'-0" RIGID INSULATION TO REMAIN
EXISTING CONCRETE FOOTING TO REMAIN
NEW CONTINUOUS METAL DRIP FLASHING,
PAINT
NEW WALL SYSTEM
EXISTING CONCRETE FLOOR SLAB AND
2'-0" RIGID INSULATION TO REMAIN
EXISTING CONCRETE FOOTING TO REMAIN
NEW CONTINUOUS METAL DRIP FLASHING,
PAINT
NEW WALL SYSTEM
NEW VINYL NAIL-FIN WINDOW
NEW WALL SYSTEM:
· NEW CEMENTITIOUS SIDING PANELS AND TRIM,
REFER TO ELEVATIONS, PAINT
· NEW 3 8" FURRING MOUNTED VERTICALLY AT
24" OC
· NEW INFILTRATION BARRIER
· EXISTING PLYWOOD SIDING TO REMAIN;
REFER TO ELEVATION NOTES FOR SIDING
REPLACEMENT WHERE REQUIRED
· EXISTING 2x4 OR 2x6 WOOD STUDS AT 16" OC
WITH LET-IN BRACING TO REMAIN
· EXISTING 2" FIBERGLASS BATT INSULATION
WITH FOIL FACE TO REMAIN
· EXISTING 5 8" TYPE 'X' INTERIOR GYPSUM
WALLBOARD TO REMAIN
A3.1
A3.1
A3.1
A3.1
A8.0TYP
A8.0TYP
A8.0TYP
A8.0TYP
A8.0TYP
A8.0TYP
A8.0TYP
A8.0TYP
A3.1
EXISTING ROOF SYSTEM:
· ASPHALT SHINGLE ROOFING TO REMAIN
· 30 LB FELT UNDERLAYMENT TO REMAIN
· 5/8" PLYWOOD SHEATHING TO REMAIN
· PRE-MANUFACTURED TRUSSES TO REMAIN
· FIBERGLASS BATT INSULATION TO REMAIN
· BLOWN-IN INSULATION TO REMAIN
· 5
8" TYPE 'X' GYPSUM WALLBOARD CEILING TO REMAIN
EXISTING ROOF SYSTEM
EXISTING FASCIA AND SUB-FASCIA TO
REMAIN, REFER TO ELEVATION NOTES
FOR REPLACEMENT WHERE OCCURS,
PAINT
NEW GUTTER AND DOWNSPOUT
EXISTING FASCIA AND SUB-FASCIA TO
REMAIN, REFER TO ELEVATION NOTES
FOR REPLACEMENT WHERE OCCURS,
PAINT
NEW GUTTER AND DOWNSPOUT
A3.0
A8.0TYP
EXISTING STRUCTURAL HEADER TO REMAIN
NEW WINDOW TRIM AND FLASHING, PAINT
NEW SILL PAN FLASHING WITH
END DAMS
A8.0
A8.0TYP
EXISTING STRUCTURAL HEADER TO REMAIN
NEW WINDOW TRIM AND FLASHING, PAINT
EXISTING STRUCTURAL HEADER TO REMAIN
NEW CONTINUOUS METAL DRIP FLASHING,
PAINT
NEW 5/4x10 TRIM BOARD, PAINT
A8.0
A3.0
FIELD VERIFY
T.O. PLATE
9'-0"
FIELD VERIFY
FIN. FLR.
0'-0"
T.O. PLATE
9'-0"
FIELD VERIFY
FIN. FLR.
0'-0"
T.O. PLATE
9'-0"
FIELD VERIFY
FIN. FLR.
0'-0"
EXISTING FASCIA AND SUB-FASCIA TO
REMAIN, REFER TO ELEVATION NOTES
FOR REPLACEMENT WHERE OCCURS, PAINT
NEW CEMENTITIOUS BOARD AND BATTEN
SIDING, PAINT
A3.1 EXISTING ROOF SYSTEM
A8.0
NEW CONTINUOUS METAL DRIP FLASHING,
PAINT
NEW 5/4x10 TRIM BOARD, PAINT
A8.0
EXISTING FASCIA AND SUB-FASCIA TO
REMAIN, REFER TO ELEVATION NOTES
FOR REPLACEMENT WHERE OCCURS, PAINT
NEW CEMENTITIOUS BOARD AND BATTEN
SIDING, PAINT
AutoCAD SHX Text O
AutoCAD SHX Text
SALEM, OREGON
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text T
AutoCAD SHX Text D
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text
RICHARD S. ROTHWEILER
A8.0
SCALE:1 DOOR TYPES
1/4" = 1'-0" 2274-A80-01
A
6' -8
FIBERGLASS
(FG)
3'-0"
B
6' -8
WOOD
PER DOOR
SCHEDULE
GL
C VINYL
6' -8
6'-0"
GL GL
6'-0"
3' -6
" 8 A8.0
A8.0
A8.0
1 VINYL 2 VINYL 3
5'-0"
5' -0
SCALE:3 WINDOW TYPES
1/4" = 1'-0" 2274-A80-03
1'-0"
6' -0
3' -6
A8.0
VINYL
A8.0
A8.0
2' -0
1' -0
NOTE: ALL EXTERIOR GLAZING TO BE INSULATED, TEMPERED
A8.0
A8.0
FINISH
FLOOR
A8.0
A8.0
A8.0
4 VINYL 5 VINYL 6 VINYL 7 VINYL 8 VINYL 9 VINYL
8'-0"
5' -0
2'
-0
A8.0
4'-0"
4' -0
3'
-0
3'-0"
3' -0
4'
-0
4'-0"
3' -0
4'
-0
5'-0"
3' -0
4'
-0
5'-0"
4' -0
3'
-0
A8.0
A8.0
A8.0
A8.0
A8.0
A8.0
A8.0
A8.0
A8.0
A8.0
A8.0
A8.0
A8.0
A8.0
A8.0
SCALE:2 DOOR FRAMES
1/4" = 1'-0" 2274-A80-02
WOOD1
6' -8
2"
6' -1
0"
2"
PER DOOR
SCHEDULE
2"
PER DOOR
SCHEDULE
HOLLOW
METAL2
6' -8
2"
6' -1
0"
2" 3'-0"
2" 3'-4"
6' -8
2"
6' -1
0"
VINYL3
2" 6'-0"
6'-4" 2"
A8.0
A8.0
A8.0
A8.0
NEW 3 4"x 5" MDF STOOL, PAINT
SCALE:
VINYL WINDOW SILL
11 3" = 1'-0" 2274-A80-11
NEW VINYL WINDOW SILL / TRACK
NEW WOOD BLOCKING AS REQUIRED
NEW SEALANT AND BACKER ROD
NEW 3 4"x21
2" CEMENTITIOUS TRIM, PAINT
NEW INFILTRATION BARRIER; REFER TO
NEW FOIL-FACED SELF-ADHERING FLASHING,
EXTEND 6" OVER INFILTRATION BARRIER; AND
6" UP JAMB; REFER TO DETAIL
EXISTING WALL SYSTEM PER DETAIL
NEW SEALANT, CONT
NEW 3 8" FURRING AT 24" OC
NEW CEMENTITIOUS LAP SIDING (BOARD AND
BATTEN SIDING INSTALLATION SIMILAR), PAINT
NEW 3 4" x 3 32" CAPILLARY BREAK / DRAIN
PATH, CONTINUOUS
NEW SEALANT, CONT
NEW 5 8" AIR SEAL, CONT
NEW 0.051" ALUM SILL PAN, CONT WITH END
DAMS; REFER TO DETAIL
NEW 3 4" x 2 12"
WOOD TRIM,
PAINT
NEW 3 4"x 2 12" WOOD
BLKG
4"
4"11
2"
(FV)
A8.0
SCALE:
VINYL WINDOW HEAD
4 3" = 1'-0" 2274-A80-04
NEW INFILTRATION BARRIER, LAP
OVER FLASHING
EXISTING WALL SYSTEM:
· 5
8" GYPSUM WALLBOARD
· 2x4 OR 2x6 WOOD STUDS AT 16" OC
· 5
8" GYPSUM SHEATHING
· 1
2" PLYWOOD (ORIG) SIDING (WHERE
OCCURS)
NEW ALUM FLASHING, CONT, LAP
OVER TRIM, PAINT
1 4"
NEW WOOD WINDOW
CASING AND TRIM
NEW VINYL WINDOW HEAD
NEW SEALANT
AND BACKER ROD
NEW 3 4" x 21
2" CEMENTITIOUS TRIM;
ANCHOR TO FURRING PER MFG
REQUIREMENTS
NEW FOIL-FACED SELF-ADHERING
FLASHING; REFER TO DETAIL
NEW 3 8" FURRING AT 24" OC AND EDGES;
ANCHOR TO EXISTING STUDS
NEW CEMENTITIOUS SIDING (LAP SIDING SHOWN,
BOARD AND BATTEN SIDING CONST SIMILAR), PAINT
EXISTING WOOD HEADER
4"
NEW ALUM INSECT SCREEN,
CONT AT BASE OF FURRING
4"
6"
4"HEM
4"
NEW ALUM FLASHING, CONT
4"
4"HEM
1"
1 2"
A8.0
SCALE:
VINYL WINDOW JAMB
8 3" = 1'-0" 2274-A80-08
NEW INFILTRATION BARRIER, LAP
OVER WINDOW FLASHING AND WINDOW FIN
EXISTING WALL SYSTEM:
· 5
8" GYPSUM WALLBOARD
· 2x4 OR 2x6 WOOD STUDS AT 16" OC
· 5
8" GYPSUM SHEATHING
· 1
2" PLYWOOD (ORIG) SIDING (WHERE
OCCURS)
NEW WOOD WINDOW CASING AND TRIM
NEW VINYL WINDOW JAMB
NEW SEALANT AND BACKER ROD,
CONTINUOUS, EACH SIDE
NEW 3 4" x 21
2" CEMENTITIOUS TRIM, PAINT
NEW FOIL-FACED SELF-ADHERING
FLASHING PER DETAIL
NEW 3 8" WOOD FURRING AT 24" OC AND
EDGES; ANCHOR TO EXISTING STUDS
NEW CEMENTITIOUS SIDING, PAINT
NEW SEALANT, CONTINUOUS
AIR SPACE BETWEEN FURRING STRIPS
1 2"
A8.0
SCALE:
BOTTOM OF WALL
10 3" = 1'-0" 2274-A80-10
EXISTING WALL SYSTEM PER
EXISTING CONCRETE
FOOTING TO REMAIN
FINISH FLOOR
NEW INFILTRATION BARRIER CONT OVER
EXIST SIDING; LAP OVER BOT FLASHING
NEW ALUM INSECT SCREEN, CONT AT
BASE OF FURRING
1" VI
F
1 4"
NEW CEMENTITIOUS BLOCKING,
CONTINUOUS
NEW 3 8 " FURRING AT 24" OC; ANCHOR
TO EXISTING STUDS
FINISH GRADE
11 4" M
IN
2"
EXISTING CONC
SLAB TO REMAIN
6"
8"
1 2"
2"
1"
2"
NEW ALUM BOTTOM
FLASHING,
CONTINUOUS AT
BASE OF SIDING
NEW 3" WIDE POLY-FACED
SELF-ADHERING FLASHING, CONT
NEW 516" CEMENTITIOUS SIDING CONT,
PAINT
A3.1
NEW PRE-PRIMED FINGER JOINTER COMBO
FRAME, PRE-HUNG WITH DOOR PER
SCHEDULE, PAINT
NEW DOOR, SEE SCHEDULE, PAINT
SCALE:
DOOR HEAD (JAMB SIM)
5 3" = 1'-0" 2274-A80-05
4"
1 2"
4"
1 2"
16" 113
16"
1 4"
NEW 9" SELF-ADHERING FLASHING
NEW INFILTRATION BARRIER; LAP OVER
FLASHING
NEW CEMENTITIOUS LAP SIDING (BOARD AND
BATTEN SIDING INSTALLATION SIMILAR), PAIN
EXISTING WALL SYSTEM PER DETAIL
NEW 1" x 21
2" CEMENTITIOUS TRIM, PAINT
NEW SEALANT, CONTINUOUS
NEW ALUM FLASHING,
CONT; LAP OVER TRIM, PAINT
NEW 3 8 " FURRING AT 24" OC;
ANCHOR TO EXISTING STUDS
NEW 12" x 21
2" PT WOOD BLOCKING
NEW ALUM INSECT SCREEN, CONT AT BASE
OF FURRING
6"
2"
HEM
NEW 9" SELF-ADHERING FLASHING
NEW INFILTRATION BARRIER; LAP OVER
FLASHING
SCALE:
EXTERIOR DOOR HEAD
9 3" = 1'-0" 2274-A80-09
NEW CEMENTITIOUS LAP SIDING (BOARD
AND BATTEN SIDING INSTALLATION
SIMILAR), PAINT
EXISTING WALL SYSTEM PER DETAIL
1 4"
EXISTING HM DOOR HEAD OR NEW HM
DOOR HEAD AS REQUIRED, PAINT
NEW 1" x 21
2" CEMENTITIOUS TRIM, PAINT
NEW SEALANT, CONTINUOUS
NEW DOOR PER SCHEDULE, PAINT
NEW ALUM FLASHING,
CONT; LAP OVER TRIM, PAINT
NEW 3 8 " PT FURRING AT 24" OC;
ANCHOR TO EXISTING STUDS
NEW 12" x 21
2" PT WOOD BLOCKING
NEW ALUM INSECT SCREEN, CONT AT BASE
OF FURRING
6"
2"
4"HEM
1"
SCALE:
EXTERIOR DOOR JAMB12 3" = 1'-0" 2274-A80-12
NEW WEATHER-RESISTANT BARRIER
NEW 3 4" x 21
2" CEMENTITIOUS TRIM, PAINT
NEW CEMENTITIOUS SIDING, PAINT
EXISTING WALL SYSTEM PER
NEW 3 4" x 31
2" CEMENTITIOUS TRIM;
LAP AT CORNER, PAINT
NEW SEALANT, CONTINUOUS, TYP
D O
O R
O
PE
N
IN
G
EX
IS
TI
N G
W
AL
L
SY
ST
EM
PE
R
/A
9.
NEW 1" x 21
2" CEMENTITIOUS TRIM AT JAMB,
PAINT
NEW SEALANT, CONTINUOUS, TYPICALNEW WOOD DOOR
PER SCHEDULE
NEW WEATHER-RESISTANT BARRIER
NEW SEALANT, CONTINUOUS, TYPICAL
NEW CEMENTITIOUS SIDING, PAINT
NEW 1x2 CEMENTITIOUS CORNER TRIM, PAINT
NEW HM DOOR JAMB AS
REQUIRED, PAINT
NEW 12" x 21
2" PT WOOD BLOCKING AS
REQUIRED, CONTINUOUS
NEW 3 8" FURRING AT 24" OC;
ANCHOR TO EXISTING STUDS
NEW 3 8" FURRING AT 24" OC; ANCHOR TO
EXISTING STUDS
SCALE:
CEMENTITIOUS TRIM AT 2nd FLOOR 6 3" = 1'-0" 2274-A80-06
NEW INFILTRATION BARRIER, LAP
OVER FLASHING
EXISTING WALL SYSTEM PER
NEW ALUM FLASHING, CONT, LAP
OVER TRIM
1 4"
NEW 5 4 x 10 CEMENTITIOUS TRIM
NEW CEMENTITIOUS SIDING
4"
6"
2"
NEW ALUM INSECT SCREEN, CONT AT
BASE OF FURRING
NEW 3 8" FURRING AT 24" OC; ANCHOR TO
EXISTING STUDS
1 4" 1 2"
2nd FLOOR ELEV
9'-0"
NEW 516" CEMENTITIOUS PANEL
WHERE OCCURS
NEW 1x3 CEMENTITIOUS BATTENS
WHERE OCCURS
NEW SEALANT, CONT
NEW INFILTRATION BARRIER; EXTEND TO 6"
ABOVE 2nd FLOOR ELEV
A3.2 SIM
SHA SCATTERED
SITES PROJECTS
SHEET
DRAWN:
REVISIONS:
JOB NO.:
DATE:
2022.0074
SEPT 20, 2022
In the event conflicts are discovered between the original signed and sealed documents prepared by the Architects and/or their Consultants, and any copy of the documents transmitted by mail, fax, electronically or otherwise, the original signed and sealed documents shall govern.
ARCHITECTURE
C O M M U N I T Y 1100 Liberty Street SE Suite 200 Salem, OR 97302 P: 503.581.4114 www.accoac.com
5132 SUNNYSIDE ROAD SE
SALEM, OREGON 97301
SCALE:7
TYPICAL EXT. WINDOW/DOOR FLASHING SYSTEM
N.T.S. 2274-A80-07
TYPICAL WINDOW/DOOR FLASHING
NOTES:
A: WINDOW OPENING SHOWN. DOORS
ARE SIMILAR WITH NO SILL
APPLICATION. REFER TO ASSOCIATED
DETAILS. REFER TO SPECIFICATIONS.
B. REFER TO FLEXIBLE MEMBRANE
MANUFACTURER'S PRODUCT
LITERATURE AND SPECIFICATIONS
FOR ANY PRE-PRIMING
REQUIREMENTS PRIOR TO
MEMBRANE INSTALLATION. PROTECT
WINDOW FRAME AND GLASS FROM
OVER-SPRAY IF USING ADHESIVE
SPRAY PRIMER.
C. THE FOLLOWING NOTES OCCUR IN
CORRESPONDING NUMBER
INSTALLATION SEQUENCE.
SEQUENCE OF INSTALLATION:
1. 12" HIGH STRIP OF INFILTRATION
BARRIER. EXTEND 10" BEYOND JAMB
(FASTEN TOP EDGE ONLY UNTIL ITEM
12 HAS BEEN INSTALLED).
2. FLEXIBLE MEMBRANE FLASHING
STRIP COVERING SILL AND EXTENDING
UP JAMB 6". LAP 6" MIN. OVER
INFILTRATION BARRIER.
3. INSTALL METAL SILL PAN WITH END
DAMS AT SILL, SET IN MASTIC.
4. FLEXIBLE MEMBRANE JAMB STRIP
FLASHING TO 6" ABOVE HEAD. LAP
COMPLETELY OVER SILL (2 AND 3).
WRAP INTO JAMB THE DEPTH OF THE
WINDOW UNIT ONLY. EXTERIOR FACE
TO BE MIN. 6" WIDE.
5. NOT USED
6. INSTALL SPACER WASHERS OVER
SILL PAN (3).
7. APPLY CONTINUOUS SEALANT BEAD
TO BACKSIDE OF WINDOW HEAD AND
SIDE NAILING FLANGES. INSTALL
WINDOW UNIT (7). BOTTOM FLANGE
RESTS AGAINST WASHERS (6) AND IS
NOT SEALED TO WALL.
8. APPLY SEALANT TO ALL FOUR
CORNERS OF WINDOW UNIT. BEAD TO
EXTEND 1" ALONG BOTH LEGS OF
EACH CORNER.
9. 6" HIGH METAL DRIP CAP FLASHING
OVER WINDOW HEAD. SET IN
CONTINUOUS BEAD OF SEALANT.
10. 9" WIDE FLEXIBLE MEMBRANE JAMB
FLASHING OVER WINDOW NAILING
FLANGES. EXTEND TO 6" ABOVE
FRAME HEAD AND 7" BELOW FRAME
SILL.
11. 9" HIGH FLEXIBLE MEMBRANE
FLASHING OVER WINDOW HEAD
NAILING FLANGE AND DRIP CAP
FLASHING. EXTEND 12" BEYOND
WINDOW JAMBS.
12. INFILTRATION BARRIER INSTALLED
UNDER BUILDING PAPER SILL STRIP
COURSE (1) AND JAMB FLASHING (4
AND 10).
13. INFILTRATION BARRIER, INSTALL
EACH COURSE OVERLAPPING PRIOR
COURSE SHINGLE FASHION. HOLD 1"
AWAY FROM SIDES OF WINDOW
FRAME.
14. SEAL SIDE EDGES OF INFILTRATION
BARRIER WITH SEALANT OR FLEXIBLE
MEMBRANE FLASHING.
BEFORE WINDOW
INSTALLATION
AFTER WINDOW INSTALLATION AFTER
INFILTRATION BARRIER
INSTALLATION
6"
SCALE:16
ROOF TO WALL FLASHING
1 1/2" = 1'-0" 2274-A80-16
EXISTING ASPHALT SHINGLES OVER 30 LB
FELT UNDERLAYMENT
NEW PRE-FINISHED METAL STEP FLASHING
EXISTING OR EXISTING PLYWOOD
SHEATHING
6"
2"
8"
4" 2"
EXTEND BUILDING PAPER UP WALL 8" MIN
NEW 12" SELF-ADHERING FLASHING (SAF). LAP
OVER STEP FLASHING TO 2" ABOVE ROOF DECK
NEW INFILTRATION BARRIER. LAP OVER
SAF 6" MIN
6"
SCALE:14
RAKE END FLASHING
1 1/2" = 1'-0" 2274-A80-14
EXISTING 2x FASCIA, REMOVE AND
RE-INSTALL AS SHOWN; REFER TO
ELEVATION NOTES FOR FASCIA
REPLACEMENT, IF REQUIRED; CAP LOWER
ENDS WITH CEMENTITIOUS FILLER AND/OR
TRIM AS REQUIRED FOR CLEAN-LINE FIT AT
INTERSECTION WITH OVERHANG FASCIA,
PAINT
6" 4"
1"
EXISTING ASPHALT
SHINGLES
EXISTING ROOF SHEATHING
EXISTING ALUM DRIP
FLASHING, CONT, PAINT
NEW 2x4 PT WOOD
BLOCKING, CONT
NEW 116" MESH ALUM BUG
SCREEN, CONT; STAPLE THRU
WRB TO EXISTING PLYWOOD
SHEATHING; WRAP OVER
FURRING AND STAPLE TO
2" BLOCKING
NEW WEATHER-RESISTANT
BARRIER. EXTEND TO EXIST
ROOF SHEATHING
1 2"
EXISITNG 30 LB FELT
UNDERLAYMENT
EXISTING SELF-ADHERING
FLASHING 12" WIDE
EXISTING SELF-ADHERING FLASHING
30" WIDE AT ROOF SURFACE.
NEW 12" x 11
2" PT WOOD
BLOCKING, CONT ALONG
SLOPE OF RAKE END
HEM
EXISTING WOOD
FRAMING
2"
1"HEM
9"
NEW ALUM DRIP FLASHING, CONT
ALONG FASCIA, PAINT
TRIM TOP EDGE OF SIDING TIGHT TO
BLOCKING; APPLY SEALANT BEAD TO
JOINT, CONT
SCALE:
LINE OF DOOR FRAME BEYOND
NEW DOOR AS SCHEDULED
NEW ALUMINUM PEMKO
THRESHOLD (SET IN MASTIC)
EXISTING 12" EXPANSION JOINT MATERIAL
WITH CONTINUOUS SELF LEVELING
SEALANT AT TOP
SCALE:SCALE:13
THRESHOLD
3"=1'-0" 2234-A80-13
NEW WRB-LAP OVER FLASHING
EXISTING PLYWOOD SHEATHING
WHERE REQ. TYP.
EXTERIOR CLADDING PER
ELEVATION TYP., PAINT
NEW COUNTER FLASHING OVER
BLOCKING-LAP 4" UP WALL AND
3" DOWN FLASHING
NEW FLASHING-LAP 5" UP WALL
AND 12" DOWN ROOF
EXISTING 5/8" TYPE 'X' GYP. TYP.
EXISTING PLYWOOD ROOF
SHEATHING PER PLAN
EXISTING UNDERLAYMENT PER
PLAN -LAP UP SIDEWALL 12" MIN.
EXISTING ROOFING
NEW 1x BLKG AT 24" O.C.
MAINTAIN 3/4" AIRSPACE
BETWEEN FLASHING AND
SHEATHING AND FLASHING AND
FLASHING
3 1/4" O.D. HOLE WITH
BUG SCREEN AT EA.
STRUCT. BAY TYP.
(8 SQ. IN. NFVA)
1" MIN. TYP. VENT
SPACE BTWN. TOP OF
INSUL. AND BTM. OF ROOF
SHEATHING. 1 1/2" WHERE
NOTED.
SCALE:15
ROOF TO WALL
3/4"=1'-0" 2274-A80-15
EXISTING SHEATHING PER PLAN
NEW WEATHER RESISTANT
BARRIER CONTINUOUS AT
CORNERS WITH NO BREAK FOR
A MIN. OF 12"
NEW SEALANT TYP.
NEW SIDING PER ELEVATION TYP.,
PAINT
NEW FLASHING PAPER OVER
WATER RESISTANT BARRIER
EXTENDING 8" MIN. EA SIDE OF
CORNER
NEW 1" x 1" WOOD TRIM, PAINT
SCALE:17
CORNER TRIM
3/4"=1'-0" 2274-A80-17
NEW WOOD CORNER TRIM TYP.,
PAINT
NEW WEATHER RESISTANT
BARRIER CONTINUOUS AT
CORNERS WITH NO BREAK FOR
A MIN. OF 12"
8"
2"
1" 51 2"
NEW EXTERIOR SIDING PANEL
PER ELEVATION TYP., PAINT
EXISTING SHEATHING PER WALL
TYPE
AutoCAD SHX Text O
AutoCAD SHX Text
SALEM, OREGON
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text T
AutoCAD SHX Text D
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text
RICHARD S. ROTHWEILER
File details come from the government source that posted it. Updated .