This is a construction plans document prepared for Collier County, Florida, detailing entrance improvements to the South County Regional Water Treatment Plant located at 3851 City Gate Drive, Naples, Florida 34117. The project involves reconfiguration of the facility entrance along City Gate Drive and White Lake Boulevard, including installation of two 18-foot swing gates, a proposed 6-foot precast privacy wall (240 linear feet), a new 8-foot by 10-foot guard house, relocation of security gate turnstiles, and modifications to the roadway and parking areas. The scope of work encompasses 1,530 square yards of total work area with specific quantities including 372 square yards of asphalt pavement removal, 40 square yards of concrete curbing removal, 12 square yards of concrete sidewalk removal, 320 linear feet of chain link fence removal, and 12 metal bollards. The construction plans were revised multiple times, with the final revision dated September 14, 2022, and prepared by Capital Consulting Solutions under the direction of engineer Adam Ahmad, P.E. The project is classified as an insubstantial change to Site Development Permit Application 20200001743.
The construction plans specify compliance with Florida Department of Transportation FY 2021-22 Standard Specifications and Collier County standards for all roadway work, utility construction, and stormwater management. The project includes milling and resurfacing of asphalt pavement with 1.5 inches of Superpave asphalt type SP-9.5, installation of Type F and Type D concrete curbing and gutter, 6-inch concrete sidewalk construction at various locations totaling 76 square yards, installation of Type B chain link fencing totaling 238 linear feet with barbed wire attachment, construction of concrete flumes for drainage, and placement of riprap for erosion control. All construction work requires coordination with existing utilities including water, wastewater, irrigation, stormwater, and electrical systems. The contractor is responsible for environmental compliance, erosion and sediment control measures, protection of existing above-ground features, maintenance of traffic flow, and coordination with Collier County Public Works Department for sign relocation and utility adjustments.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SCRWTP_PROJECT_3851_CITY_GATE_DR.pdf | ||
| Insurance_Requirements_Template.docx | DOCX document | |
| South_County_Regional_Water_Treatment_Plant_-_Guard_House.pdf | ||
| Quick_Quotes_Instructions_Version_1_.pdf | ||
| PO_Terms_and_Conditions.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N.T.S.
N
SHEET NO. SHEET DESCRIPTION
PROJECT LOCATION
VICINITY MAP
NOT TO SCALE
ENGINEER OF RECORD:
DATE:
www.callsunshine.com
KNOW WHAT'S BELOW
ALWAYS CALL 811
BEFORE YOU DIG
.START OF WORK OPERATIONS
CONTRACTOR PRIOR TO THE
SHALL BE VERIFIED BY THE
CONSIDERED APPROXIMATE AND
ON CONST. PLANS ARE TO BE
ALL EXISTING UTILITIES SHOWN
It's the law.
It's fast. It's free.
ADAM AHMAD, P.E. P.E. NO. 72472
INDEX OF PLANS
COLLIER COUNTY
PLANS OF PROPOSED:
PROJECT LOCATION MAP
COUNTY
COLLIER
NO.
SHEET
SECTION 35, TOWNSHIP 49S, RANGE 26E
LOCATION
PROJECT
KEY SHEET1
HTTP://WWW.FDOT.GOV/PROGRAMMANAGEMENT/IMPLEMENTED/SPECBOOKS
SPECIFICATIONS CAN BE FOUND AT THE FOLLOWING WEBSITE:
THE PUBLIC RIGHTS-OF-WAY, COLLIER COUNTY, FLORIDA.
LATEST EDITION OF THE CONSTRUCTION STANDARDS HANDBOOK FOR WORK WITHIN
FOR ROAD AND BRIDGE CONSTRUCTION.
FLORIDA DEPARTMENT OF TRANSPORTATION, JANUARY 2021 STANDARD SPECIFICATIONS
FISCAL YEAR 2021-22.
FLORIDA DEPARTMENT OF TRANSPORTATION ROADWAY STANDARD PLANS
GOVERNING STANDARDS AND SPECIFICATIONS:
ADVANCE MOT CERT. NO. 28347
CERT. OF AUTH. NO. 32121
PHONE: (239) 273-8894
NAPLES, FL 34109
9010 STRADA STELL CT, SUITE 108
CAPITAL CONSULTING SOLUTIONS
TYPICAL SECTION
TOPOGRAPHIC SURVEY
4 CLEARING & GRUBBING PLAN
CROSS SECTIONS
UTILITY ADJUSTMENTS
2 EROSION CONTROL & GENERAL NOTES
PHONE: (239) 252-6245
NAPLES, FL 34117
3851 CITY GATE DRIVE
COLLIER COUNTY
OWNER:
A/PU
ZONING DESIGNATION:
LESS REFERENCED PAR A DESC IN OR 3965 PG 2871.
S89DEG W690.82FT, N653.80FT, S89DEG W454.28FT, N100FT POB
N31DEG E 70.02FT, S58DEG 761.56FT, S1066.70FT, S332.74FT,
N89DEG E100FT, N50FT POB N89DEG E456.51FT, N994.98FT,
PG 1257 FURTHER DESC AS: COMM 1/4 CNR SEC 35, N1382.43FT,
35 49 26 PARCEL 3.1 WATER TREATMENT PLANT DESC IN OR 1022
LEGAL DESCRIPTION:
AGENT:
OF REQUIRED IMPROVEMENTS WHICH ARE INCONSISTENT WITH EASEMENT OF RECORD.
NOTE: THE APPROVAL OF THESE CONSTRUCTION PLANS DOES NOT AUTHORIZE CONSTRUCTION
-- FY 2021-22 FDOT STANDARD PLANS INDICES
8 INTERSECTION DETAIL SHEET
ENTRANCE PLAN
ENTRANCE LAYOUT & PROFILE
INSUBSTANTIAL CHANGE TO SDPA 20200001743
PROPERTY ID NO: 00298280001
3851 CITY GATE DR., NAPLES, FL 34117
ENTRANCE IMPROVEMENTS
REGIONAL WATER TREATMENT PLANT PU-81-14C
SITE DEVELOPMENT SOUTH COUNTY
REVISED SEPT. 14, 2022
CONSTRUCTION PLANS
3 4
9-14-22 4 SOUTH & NORTH SIDE REVISIONS.
C.L. FENCE & MINOR REVISIONS.
8-16-22 3 PRIVACY WALL, ENTRANCE SIGN,
4-1-22 2 C.L.F. & GATE/ARM REVISIONS.
12-22-21 1 SHEET REVISIONS FOR SWING GATES.
REVISIONS:
DATE DESCRIPTION
REVISIONS
NO.
SHEET
PROJECT NAME
BOARD OF COUNTY COMMISSIONERS
COLLIER COUNTY
DATE
ADVANCE MOT CERT. NO. 28347
CERT. OF AUTH. NO. 32121
ADAM AHMAD, P.E. NO. 72472
PHONE: (239) 273-8894
9010 STRADA STELL CT, STE 108, NAPLES, FL 34109
CAPITAL CONSULTING SOLUTIONS CONSTRUCTION PLANS
3851 CITY GATE DRIVE, NAPLES, FL 34117
SOUTH COUNTY REGIONAL WTP
ENTRANCE IMPROVEMENTS
12-22-21 1 SHEET REVISIONS FOR SWIING GATES.
4-1-22 2 C.L.F. & GATE/ARM REVISIONS.
REV. AUG. 16, 2022
JAN. 24, 2022
8-16-22 3 PRIVACY WALL, ENTRANCE SIGN, C.L. FENCE & MINOR REV.
GENERAL NOTES:
V E
R T
IC
A L
SILT FLOW
N.T.S.
EROSION & SEDIMENT CONTROL
FILTER FABRIC
OPTIONAL POST POSITIONS
PRINCIPLE POST POSITION
(CANTED 20° TOWARD FLOW)
POST OPTIONS: WOOD MIN. 2-1/2"
WOOD = 2" x 4"
OAK = 1-1/2" x 1-1/2"
STEEL = 1.33 LBS / FT. MIN.
FILTER FABRIC (IN
CONFORMANCE W/
SEC. 985 FDOT SPEC.)
ELEVATION
SECTION
EROSION CONTROL NOTES:
6' MAX.
3' OR MORE
12" MIN.
15" TO 18"
8"
PRE-INSPECTION MEETING.
LOCAL PUBLIC WORKS MAINTENANCE DEPARTMENT FOR A SOIL EROSION AND SEDIMENT CONTROL
5. PRIOR TO START OF THE CLEARING AND GRUBBING OPERATIONS, OR ANY SOIL DISTURBANCE, CONTACT
WETLANDS, OFF-SITE FLOODING OR VIOLATION OF WATER QUALITY STANDARDS.
NOT RESULT IN EROSION AND SEDIMENT DEPOSITION IN WETLANDS OR OFF-SITE, ADVERSE IMPACTS TO
4. THIS PLAN PROVIDES REASONABLE ASSURANCE THAT THE PROPOSED CONSTRUCTION ACTIVITIES WILL
DRAIN PIPES AND STRUCTURES SHALL BE FLUSHED CLEAN AFTER CONSTRUCTION.
EROSION CONTROL METHODS AS SHOWN OR APPROVED BY THE PROJECT ENGINEER. ALL NEW AND EXISTING
DRY OR WET WATERCOURSE. RECOMMENDED EROSION CONTROL SHALL CONSIST OF SILT FENCE, OR OTHER
APPROVED EROSION CONTROL DEVICES SHALL BE INSTALLED TO PREVENT DISCHARGE OF SEDIMENT INTO A
3. THE CONTRACTOR SHALL PREVENT THE DISCHARGE OF SEDIMENT DUE TO CONSTRUCTION OPERATIONS.
CONSTRUCTION.
DISTURBED FOUNDATIONS, IMPACT TO STRUCTURES, AND ANY OTHER DAMAGE CAUSED DURING
MINIMIZED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY EROSION, SEDIMENT TRANSPORT, PHASES OF CONSTRUCTION SUCH THAT IMPACT TO CONSTRUCTION AND/OR SURROUNDING FACILITIES IS
MAINTAIN A CLEAR PATH FOR ALL SURFACE WATER DRAINAGE STRUCTURES AND DITCHES DURING ALL
WORK APPEARS TO INTERRUPT AN EXISTING STORM WATER DRAINAGE PATTERN. THE CONTRACTOR SHALL
SHOWN ON THESE PLANS ARE TO BE MAINTAINED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IF THE
2. ALL EXISTING STORM WATER DRAINAGE PATTERNS AND SWALES OUTSIDE THE CONSTRUCTION AREAS
AND GRUBBING LIMITS.
BE INSTALLED ALONG THE ENTIRE PERMITTER OF THE PROJECT AREA AS ESTABLISHED BY THE CLEARING
1. FOR SILT FENCE SEDIMENT BARRIER, SEE DETAIL THIS SHEET. PROPOSED LOCATION IN THE FIELD SHALL
& GENERAL NOTES
EROSION CONTROL
GRADED AND SODDED AS SPECIFIED IN THE APPROVED CONSTRUCTION PLANS.
UPON COMPLETION OF SITE IMPROVEMENTS, THE WRA'S, SWALES, AND OTHER STORMWATER MANAGEMENT DEVICES WILL BE FINAL
DEVICES CONSISTENT WITH LATEST EDITION OF THE FDOT ROAD DESIGN STANDARD INDICIES WILL BE USED.
OFF SITE DISCHARGE OF UNTREATED STORMWATER WILL BE PREVENTED USING TEMPORARY BERMS AND DIKES WHERE NEEDED.
SLOPE DRAIN PROTECTION WILL BE PROVIDED PER FDOT ROAD DESIGN STANDARDS, LATEST EDITION.
AREAS WHICH MAY ERODE DUE TO SLOPES OR CONCENTRATED RUNOFF DURING CONSTRUCTION WILL BE TREATED. TEMPORARY
ALL DISTURBED AREAS WILL BE BROUGHT TO FINAL GRADE AND SEEDED AND MULCHED AS SOON AS POSSIBLE.
SEDIMENT AND RUNOFF CONTROL DURING CONSTRUCTION.
PRIOR TO INITIATING CONSTRUCTION OF PLANNED IMPROVEMENTS, ALL WRA'S WILL BE EXCAVATED AND ROUGH GRADED TO PROVIDE
INFRASTRUCTURE ON SITE (OPEN SPACE, PAVED AREAS, COMMON AREAS, ETC.).
8. COLLIER COUNTY PUBLIC WORKS DEPARTMENT WILL BE RESPONSIBLE FOR MAINTENANCE OF THE
WATER MANAGEMENT FACILITIES.
7. COLLIER COUNTY PUBLIC WORKS DEPARTMENT WILL BE RESPONSIBLE FOR THE MAINTENANCE OF THE
STANDARD PLANS, INCLUDING MAINTENANCE OF TRAFFIC INDICES 102-600 SERIES.
REQUIRES A COUNTY PERMIT. COUNTY RIGHT OF WAY STANDARDS APPLY, IN ADDITION TO FDOT FY 2021-22
6. ALL CONSTRUCTION AND MAINTENANCE WORK WITHIN THE COUNTY PUBLIC ROADWAY RIGHT OF WAY
CONSTRUCTION OF WATER AND WASTEWATER FACILITIES SPECIFICATIONS, LATEST EDITION.
5. ALL UTILITY CONSTRUCTION SHALL COMPLY WITH THE COLLIER COUNTY STANDARDS FOR DESIGN AND
CONSTRUCTION PLANS.
SURFACE FEATURES DEPICTED TO BE REMOVED, ADJUSTED, OR RELOCATED PER
PERSONNEL ALL SITE CONDITIONS, PROPOSED IMPROVEMENTS AND EXISTING
4. CONTRACTOR TO REVIEW AND COORDINATE WITH ENGINEER AND COUNTY
WALLS, GATES, BOLLARDS, FENCING, ETC.
ADJACENT ROADWAY SURFACE FEATURES TO INCLUDE CURBING, SHOULDERS, SIDEWALKS, SIGNAGE,
3. CONTRACTOR TO TAKE CAUTION AND IMPLEMENT NECESSARY MEASURES IN ORDER TO PROTECT
BY ENGINEER TO BE IN CONFORMANCE TO ADA CRITERIA.
2. OVERLAY TRANSITIONS AT ALL AREAS OF PEDESTRIAN ACCESS ARE TO BE COORDINATED AND APPROVED
ENGINEER.
PROPOSED WORK LIMITS ARE TO BE MAINTAINED AS EXISTING UNLESS OTHERWISE DIRECTED BY THE
1. EXISTING CROSS SLOPES, LONGITUDINAL SLOPES, GRADING AND DRAINAGE PATTERNS OUTSIDE OF
GENERAL NOTES (CONT.):
REMOVAL.”
MAINTENANCE DEPT, 239-252-8924, TO SCHEDULE DROP OF DAY/TIME OF SIGNAGE SCHEDULED FOR
10. ALL SIGNAGE WITHING PUBLIC ROADWAY ROW ARE COUNTY ASSETS. CONTRACTOR TO CALL ROAD
GALVANIZED METAL SQUARE TUBULAR SIGNPOST.”
SIGNING AND PAVEMENT MARKINGS SPECIAL PROVISION DETAILS WHICH INDICATE USING A 2.5” X 2.5”
PRIOR TO REMOVAL AND PRIOR TO THE RE-INSTALLATION. CONTRACTOR TO FOLLOW TRAFFIC OPERATIONS
THAT THEIR CURRENT CONDITION IS MAINTAINED. SIGNS/POLES MUST BE INSPECTED AND DOCUMENTED
ACCOMMODATING PROPOSED IMPROVEMENTS IN THE PUBLIC ROADWAY ROW, SHALL BE STORED SUCH
OF OUR SIGN ASSET DATABASE. ALL SIGNAGE/POLES SCHEDULED FOR REMOVAL/RELOCATION WHILE
9. ALL SIGN RELATED WORK TO BE COORDINATED WITH FELIX BURGOS, 239-253-3160, TO MAINTAIN INTEGRITY
W A T E R
W A T E R
WATER
WATER
WATER WATER
IRR
IRR
ARV
SAN
NPW
NPW
SAN
1+00 2+00 3+00 x
E R
C P x
C P
DATE DESCRIPTION
REVISIONS
NO.
SHEET
PROJECT NAME
BOARD OF COUNTY COMMISSIONERS
COLLIER COUNTY
DATE
ADVANCE MOT CERT. NO. 28347
CERT. OF AUTH. NO. 32121
ADAM AHMAD, P.E. NO. 72472
PHONE: (239) 273-8894
9010 STRADA STELL CT, STE 108, NAPLES, FL 34109
CAPITAL CONSULTING SOLUTIONS CONSTRUCTION PLANS
3851 CITY GATE DRIVE, NAPLES, FL 34117
SOUTH COUNTY REGIONAL WTP
ENTRANCE IMPROVEMENTS
12-22-21 1 SHEET REVISIONS FOR SWIING GATES.
4-1-22 2 C.L.F. & GATE/ARM REVISIONS.
REV. AUG. 16, 2022
JAN. 24, 2022
8-16-22 3 PRIVACY WALL, ENTRANCE SIGN, C.L. FENCE & MINOR REV.
TOPOGRAPHIC SURVEY
S C
A L E
N
R/W LINE
R/W LINE
R
W
L I N
E R
W
L I N
E
CITY GATE DRIVE
W H
IT
E L
A K
E B
L V
D
NO.
SHEET
PROJECT NAME
BOARD OF COUNTY COMMISSIONERS
COLLIER COUNTY
DATE
ADVANCE MOT CERT. NO. 28347
CERT. OF AUTH. NO. 32121
ADAM AHMAD, P.E. NO. 72472
PHONE: (239) 273-8894
9010 STRADA STELL CT, STE 108, NAPLES, FL 34109
CAPITAL CONSULTING SOLUTIONS CONSTRUCTION PLANS
3851 CITY GATE DRIVE, NAPLES, FL 34117
SOUTH COUNTY REGIONAL WTP
ENTRANCE IMPROVEMENTS
12-22-21 1 SHEET REVISIONS FOR SWIING GATES.
4-1-22 2 C.L.F. & GATE/ARM REVISIONS.
REV. AUG. 16, 2022
JAN. 24, 2022
8-16-22 3 PRIVACY WALL, ENTRANCE SIGN, C.L. FENCE & MINOR REV.
S C
A L E
N
R/W LINE
R/W LINE
R
W
L I N
E R
W
L I N
E
CITY GATE DRIVE
W H
IT
E L
A K
E B
L V
D
CLEARING & GRUBBING PLAN
LEGEND:
DENOTES LIMITS OF CLEARING & GRUBBING
.0
E
.7
N
.9
DENOTES LIMITS OF CONCRETE REMOVAL
� CONST
DENOTES LIMITS OF ASPH. PAVEMENT REMOVAL
7. INCLUDES RELOCATION OF SECURITY GATE TURNSTILE.
6. INCLUDES 12 EA OF METAL BOLLARD REMOVAL.
5. INCLUDES 320 LF OF CHAIN LINK FENCE REMOVAL.
4. INCLUDES 12 SY OF CONCRETE SIDEWALK REMOVAL.
3. INCLUDES 40 SY OF CONCRETE CURBING REMOVAL.
2. INCLUDES 372 SY OF ASPH. PAVEMENT REMOVAL.
1. INCLUDES 1530 SY OF TOTAL WORK AREA LIMITS.
CLEARING & GRUBBING FOOTNOTES:
ELEMENTS TO BE REMOVED, RELOCATED OR TO REMAIN.
NOTE: SEE UTILITY ADJUSTMENTS SHEET FOR EXIST. SURFACE
40.77 RT
+46.12
39.42 RT
+47.60
29.71 RT
+38.67
51.60 RT
+40.28
57.09 RT
+40.28
57.09 RT
+09.77
48.50 RT
+11.25
48.50 RT
+84.59
24.86 RT
+84.17
57.70 RT
+24.94
11.64 LT
+78.49
13.84 LT
+78.32
25.40 LT
+82.77
29.52 LT
+77.51
46.16 LT
+74.76
51.40 LT
+79.08
19.27 LT
+29.76
19.27 LT
+73.61
21.90 LT
+09.34
TURNSTILE
SECURITY GATE
PAVEMENT REMOVAL (TYP)
SHEET FOR LIMITS OF ASPH.
SEE ENTRANCE PLAN-PROFILE
39.63 LT
+26.36
48.00 RT
+18.00
W A T E R
W A T E R
WATER
WATER
WATER WATER
IRR
IRR
ARV
SAN
NPW
NPW
SAN
1+00 2+00 3+00 x
C P x
C P
£ CONST.
GROUND
NATURAL
GROUND
NATURAL
TYPICAL SECTION
DATE DESCRIPTION
REVISIONS
NO.
SHEET
PROJECT NAME
BOARD OF COUNTY COMMISSIONERS
COLLIER COUNTY
DATE
ADVANCE MOT CERT. NO. 28347
CERT. OF AUTH. NO. 32121
ADAM AHMAD, P.E. NO. 72472
PHONE: (239) 273-8894
9010 STRADA STELL CT, STE 108, NAPLES, FL 34109
CAPITAL CONSULTING SOLUTIONS CONSTRUCTION PLANS
3851 CITY GATE DRIVE, NAPLES, FL 34117
SOUTH COUNTY REGIONAL WTP
ENTRANCE IMPROVEMENTS
12-22-21 1 SHEET REVISIONS FOR SWIING GATES.
4-1-22 2 C.L.F. & GATE/ARM REVISIONS.
REV. AUG. 16, 2022
JAN. 24, 2022
8-16-22 3 PRIVACY WALL, ENTRANCE SIGN, C.L. FENCE & MINOR REV.
MILLING & RESURFACING
RESURFACE W/ SUPERPAVE ASPHALT TYPE SP-9.5 (1.5")
MILL EXISTING ASPHALT PAVEMENT (1.5" CONSTANT DEPTH)
CURB & GUTTER
2' TYPE 'F'
PROPOSED
TYPICAL SECTION
+0.02
TYPE 'D' CURB
PROPOSED
+0.02 -0.02
FULL DEPTH PAVEMENT
-0.03
CURB & GUTTER
2' TYPE 'F'
PROPOSED
CROSS SECTIONS)
(SEE PLAN AND
DEPTH PAVEMENT
PROPOSED FULL
A MIN. OF 12" BEYOND THE BACK OF PROPOSED CURBING.
3. CONTRACTOR SHALL INSTALL ALL STABILIZED ROAD SUB-BASE
AND CONSTRUCTED OVER A COMPACTED BASE.
2. ALL CONCRETE SIDEWALK AND DRIVEWAY TO BE 6" THICKNESS
CROSSWALK PAVEMENT MARKINGS.
1. SEE FDOT STANDARD PLANS INDEX 711-001 FOR HIGH EMPHASIS
GENERAL NOTES:
SUB-GRADE: TYPE B STABILIZATION (LBR 40) (12")
SUB-BASE: OPTIONAL BASE GROUP 9 (10" LIMEROCK) (LBR 100)
SURFACE COURSE: SUPERPAVE ASPHALT TYPE SP-9.5 (1.5")
M
D I A
N
P R
O P
S E
C U
R I T
Y
F
E N
C E
P R
O P
S E
C U
R I T
Y
F
E N
C
X S
E C
T I O
N S
R T
P
G L
S
E E
P
L A
N P
R O
F
X S
E C
T I O
N S
L T
P
G L
S
E E
P
L A
N P
R O
F
14'
AREA
SECURED
EXIST.
AREA
SECURED
EXIST.
VARIES (12' - 24')
RAISED MEDIAN
PROPOSED
(6' - 12')
VARIES
(6' - 12')
VARIES
(18' - 14')
VARIES5.5'
(9.5' - 17.5')
VARIES
TO 3+22
STA 1+26
MILL. & RES.
(OUT-BOUND)
EXIST.
TO 3+10
STA 1+40
RECONST.
(IN-BOUND)
EXIST.
SECTIONS
CROSS
SEE
SPACE
GREEN
EXIST.
SECTIONS
CROSS
SEE
SPACE
GREEN
EXIST.
NO.
SHEET
PROJECT NAME
BOARD OF COUNTY COMMISSIONERS
COLLIER COUNTY
DATE
ADVANCE MOT CERT. NO. 28347
CERT. OF AUTH. NO. 32121
ADAM AHMAD, P.E. NO. 72472
PHONE: (239) 273-8894
9010 STRADA STELL CT, STE 108, NAPLES, FL 34109
CAPITAL CONSULTING SOLUTIONS CONSTRUCTION PLANS
3851 CITY GATE DRIVE, NAPLES, FL 34117
SOUTH COUNTY REGIONAL WTP
ENTRANCE IMPROVEMENTS
12-22-21 1 SHEET REVISIONS FOR SWING GATES.
4-1-22 2 C.L.F. & GATE/ARM REVISIONS.
8-16-22 3 PRIVACY WALL, ENTRANCE SIGN, C.L. FENCE & MINOR REV.
9-14-22 4 SOUTH & NORTH SIDE REVISIONS. REV. SEPT. 14, 2022
JAN. 24, 2022 6
6'R
12'R
M&R LIMITS
'R
'R
'R
'R
'R
CR-E
CR-E
CR-E
6" CONC S/W
CONST 20SY OF
ENTRANCE PLAN
SCALE: 1"=10'
� CONST
E
.7
N
.9
B
E G
IN
C
O N
S T
6'R
.5
'R
STA 2+30 (47.50 RT)
GATE TURNSTILE
RELOCATED SECURITY
R E
C O
N S
T
B E
G
IN
CONC TYPE F C&G
CONST 250LF OF
CONC TYPE F C&G
CONST 134LF OF
C O
N S
T
E N
D
R
E
L
IM
IT
S
M
R
L
IM
IT
S
M
R
SEE NOTE 9
TYP
6'
T Y P
SEE NOTE *
GUARD HOUSE
PROP. 8'x10'
ON A DAILY BASIS.
TO BE COORDINATED WITH COUNTY PERSONNEL
TRAFFIC AT ALL TIMES DURING CONSTRUCTION,
CONTRACTOR SHALL KEEP ONE LANE OPEN TO
ACCESS NOTE:
DBL. YELLOW
90LF OF 6"
S T
O P
4'
'R
STOP BAR +50
16LF 24" WHITE
+50 R1-1 (24"x24")
INDEX 711-001)
(SEE FDOT STD. PLANS
ON PROP. S/W RAMPS.
CROSSWALK CENTERED
10' SPECIAL EMPHASIS
P C
'R
'R
CR-E
CR-D
SURVEY CONTROL: BENCHMARK DATUM = NAVD 1988.
CONC. SIDEWALK CURB RAMP DESIGNATIONCR
PROP. STATION/OFFSET/ELEV. LOCATION
PROP. DRAINAGE, CONCRETE WORK AND FENCING.
FOR ADDITIONAL DETAILS AND INFORMATION ON
SEE FDOT FY 2020-21 STANDARD PLANS INDICES
(SOUTH IN-BOUND LANE)
LIMITS OF RECONSTRUCTION
ENTRANCE PLAN
OF ROADWAY IMPROVEMENTS.
SHEET NO. 7 FOR GEOMETRIC LOCATION
SEE ENTRANCE LAYOUT & PROFILE
NOTE:
DETECTABLE WARNING SURFACE
6" CONC S/W
CONST 45SY OF
6" CONC S/W
CONST 17SY OF
6" CONC S/W
CONST 14SY OF
(BY OTHERS)
CONC. S/W
NOTE 11
(37' RT) SEE
STA 3+02
GATE ARM
IS TO MATCH EXISTING SHALL BE SAWCUT.
5. ALL AREAS OF ASPHALT AND CONCRETE LOCATIONS WHERE RECONSTRUCTION
EXIST. CONDITIONS (SEE SHEET NO. 7, ENTRANCE LAYOUT & PROFILE).
4. ALL STATION / OFFSET LABEL LOCATIONS WITH M.E. DESIGNATION ARE TO MATCH
PULL BOXES, MECHANICAL GATE, WATER PIPING, BOLLARDS, LANDSCAPING, ETC.
BY THE ENGINEER. ABOVE GROUND FEATURES INCLUDE SIGNAGE, WATER VALVES,
OUTSIDE OF PAVEMENT LIMITS AND MAKE ADJUSTMENTS AS NECESSARY OR DIRECTED
3. CONTRACTOR SHALL PROTECT EXISTING ABOVE GROUND FEATURES WITHIN AND
PRIVACY WALL AS IT INTERFACES WITH CITY GATE DRIVE IMPROVEMENTS.
WHITE LAKE BLVD REGARDING FRONTAGE SIDEWALK, ENTRANCE SIGN AND PERIMETER
2. CONTRACTOR SHALL COORDINATE WITH CITY GATE COMMERCE PARK PROJECT ALONG
LOCATION, AND BUILDING CONNECTION FOR ELECTRIC SERVICE, ETC.
INSTALLATION AS IT INTERFACES WITH THE SURROUNDING IMPROVEMENTS, FOUNDATION
1. CONTRACTOR SHALL COORDINATE ALL ASPECTS OF THE PROPOSED GUARD HOUSE
CONSTRUCTION NOTES:
(SEE NOTE 10)
STA 2+94 (16' LT)
LEFT (WB OUT-SWING)
BARRIER SWING GATE
G A
T E
G A
T E
LIMITS
RECONST
(SEE NOTE 10)
STA 3+07 (35' RT)
RIGHT (EB OUT-SWING)
BARRIER SWING GATE
20'
NOTE 11
(16' LT) SEE
STA 3+00.00
GATE ARM
(RAISED ISLAND)
'D' CONC CURB
CONST 50LF TYPE
(RAISED ISLAND)
'D' CONC CURB
CONST 176LF TYPE
6" CONC S/W
CONST 6SY OF
ITIONS INFORMATION.
ADDITIONAL EXIST. COND-
DETAIL SHEET NO. 8 FOR
NOTE: SEE INTERSECTION
ITIONS INFORMATION.
ADDITIONAL EXIST. COND-
DETAIL SHEET NO. 8 FOR
NOTE: SEE INTERSECTION
ISLAND POSTS
BETWEEN SWING GATE
16LF PROP. PRIVACY WALL
TYPE 'B' C.L. FENCE
CONST 42LF OF
TYPE 'B' C.L. FENCE
CONST 110LF OF
TYPE 'B' C.L. FENCE
CONST 86LF OF
(NOT IN THIS CONTRACT).
AT A LATER DATE, BY OTHERS.
GUARD HOUSE TO BE INSTALLED
NOTE *3
WALL (240LF)
PROP. 6' PRECAST
WALL (240LF)
PROP. 6' PRECAST 3
(SEE BID SPECS.)
PROP. ENTRANCE SIGN
TO CLEAR CURB & GUTTER
AS DIRECTED BY ENGINEER
REPLACE EXIST. BOLLARDS
.5 'R3 'R
13. CONTRACTOR TO NOTCH BOTTOM PORTION OF PROP. CHAIN LINK AT BOTH CONC. FLUME LOCATIONS.
INDEX 550-002.
12. TYPE 'B' CHAIN LINK FENCE TO INCLUDE BARB WIRE ATTACHMENT PER FDOT STANDARD PLANS
11. SEE PROJECT SPECIFICATIONS FOR OPERATOR AND GATE ARM MOUNTING / INSTALLATION DETAILS.
A MINIMUM OF 48" FROM GATE POSTS AND FENCE LINE AND DON'T INSTALL BOLLARDS IN CONFLICT.
CONTRACTOR TO CONFIRM NO OBSTRUCTIONS EXIST WITHIN THE DIRECTION OF SWING. PROVIDE
SEE PROJECT SPECIFICATIONS FOR OPERATOR AND GATE MOUNTING / FABRICATION DETAILS.
10. SWING GATES (2 EA) ARE 18' IN LENGTH, AND TO SWING OUT WITH THE DIRECTION OF TRAFFIC FLOW.
PREVENTER. COST TO BE INCLUDED IN THE UNIT COST FOR EACH ASSOCIATED ITEM (22 TOTAL).
OF PROP. ENTRANCE SIGN, GUARD HOUSE, GATE/ARM OPERATORS, AND EXIST. BACKFLOW
9. PROTECTIVE HEAVY-DUTY BOLLARDS SHALL BE INSTALLED AT 12" OFFSET FROM ALL FOUR CORNERS
PROTECTED, AND SHORED.
ENGINEERING, GROUND PENETRATING RADAR, ETC) TO ASSURE EXIST. UTILITIES ARE LOCATED,
8. CONTRACTOR SHALL IMPLEMENT NECESSARY MEASURES (POT-HOLING, SUBSURFACE UTILITY
7. CHEVRONS AT PAINTED GORE AREA TO BE 18" YELLOW @ 5' o.c.
6. ALL CONCRETE SIDEWALK INSTALLATION TO BE CONSTRICTED PER ADA STANDARDS AND CRITERIA.
S C
A L E
N
(SEE FLUME DETAIL SHT)
CONC. FLUME (11 SY)
CONST 24LF OF
(SEE FLUME DETAIL SHT)
CONC. FLUME (20 SY)
CONST 42LF OF
RIP-RAP (0.5 TN)
CONST 6'x10'x2'
RIP-RAP (0.5 TN)
CONST 6'x10'x2'
W A T E R
W A T E R
WATER
WATER
WATER WATER
IRR
IRR
ARV
NPW
NPW
SAN
2+00 3+00 x
C P x
C P
NO.
SHEET
PROJECT NAME
BOARD OF COUNTY COMMISSIONERS
COLLIER COUNTY
DATE
ADVANCE MOT CERT. NO. 28347
CERT. OF AUTH. NO. 32121
ADAM AHMAD, P.E. NO. 72472
PHONE: (239) 273-8894
9010 STRADA STELL CT, STE 108, NAPLES, FL 34109
CAPITAL CONSULTING SOLUTIONS CONSTRUCTION PLANS
3851 CITY GATE DRIVE, NAPLES, FL 34117
SOUTH COUNTY REGIONAL WTP
ENTRANCE IMPROVEMENTS
12-22-21 1 SHEET REVISIONS FOR SWING GATES.
4-1-22 2 C.L.F. & GATE/ARM REVISIONS.
REV. SEPT. 6, 2022
JAN. 24, 2022 8-16-22 3 PRIVACY WALL, ENTRANCE SIGN, C.L. FENCE & MINOR REV.
9-6-22 4 SOUTH SIDE REVISIONS.
SCALE: 1"=10'
SCALE: 1"=10'
ENTRANCE PROFILE
� CONST
E
.7
N
.9
B
E G
IN
C
O N
S T
.5
8 9
47 48
S
T O
P
AND PROFILE
ENTRANCE LAYOUT
ENTRANCE LAYOUT
G A
T E
G A
T E
A R
M G
A T
E
A R
M G
A T
E
NO.
STATION OFFSET ELEV. DESCRIPTION
GEOMETRIC LAYOUT TABLE
1+28.67 61.50 RT M.E.
1+63.70 22.08 RT
2+03.65 35.38 RT 11.28
10.642+10.00 34.20 RT
1+93.65 26.33 RT 10.96
2+13.50 36.88 RT
2+24.66 37.79 RT 10.77
2+44.81 38.00 RT 11.10
2+64.59 38.00 RT 11.22
3+03.82 33.12 RT 11.08
3+28.86 26.78 RT
3+38.67 29.71 RT
10.65
10.92
3+47.60 39.42 RT
3+22.84 37.82 RT
PT C&G, 10' RADIUS RETURN
3+19.82 34.64 RT
3+11.59 47.50 RT
2+40.28 54.34 RT
11.52
11.52
END 6' S/W, MATCH EXIST. ASPH. PAVT.
2+38.52 51.60 RT 11.31
2+34.40 47.50 RT
2+27.92 43.75 RT
2+26.40 47.50 RT 11.08
2+31.53 57.35 RT 11.20
2+31.66 70.99 RT 10.42
2+37.03 79.42 RT M.E.
1+83.77 47.50 RT M.E.
3+01.90 19.15 RT 11.47
3+03.87 18.61 RT
3+05.98 14.99 RT
3+02.76 2.26 RT
2+99.85 11.48
11.50
2+99.41 14.00 LT
3+10.97 19.44 LT
3+05.64 21.55 LT
2+99.41 14.00 LT
2+93.60
2+10.00
11.31
2+10.00 10.89
2+00.00 14.00 LT 11.04
1+78.49 11.64 LT
1+83.77 19.27 LT
1+26.36 39.63 LT
2+02.25 11.23 RT
2+27.44 21.15 RT 11.40
2+32.37 17.13 RT 11.60
2+53.00 19.00 RT 12.14
PT C&G, 160' RADIUS
6' S/W CORNER AT TURNSTILE
CORNER 6' TYPE 'B' CHAIN LINK FENCE
2+63.96 11.64
2+05.18 11.31 PC, TYPE 'D' CURB, 6'R ISLAND BULLNOSE
2+51.96 24.00 RT 11.5647
PRC C&G, 50'/118' RADIUS
CENTER PT FLUME RETURN, 1.5' RADIUS
CENTER PT FLUME RETURN, 3' RADIUS
PT C&G, 118' RADIUS
PC C&G, 10' RADIUS RETURN
END C&G, MATCH EXIST. PARKING LOT
¡ 9' S/W AT TURNSTILE
END 6' TYPE 'B' C.L. FENCE @ GATE
CORNER 6' TYPE 'B' CHAIN LINK FENCE
END 6' TYPE 'B' CHAIN LINK FENCE
BEGIN 6' TYPE 'B' CHAIN LINK FENCE
6' S/W CORNER AT TURNSTILE
BEGIN 6' TYPE 'B' C.L. FENCE @ WALL
END C&G DEFLECTION
BEGIN NEW C&G, MATCH EXIST. C&G
BEGIN 6' TYPE 'B' C.L. FENCE @ WALL
BEGIN M & R, MATCH EXIST. C&G
49 2+57.96
2+63.96 24.00 RT
18.84 RT
11.64
12.64
PC, TYPE 'D' CURB, 12' RADIUS BULLNOSE
¡ 4' S/W CURB RAMP
¡ 5' S/W CURB RAMP, MATCH EXIST
¡ 4' S/W PT
PT, TYPE 'D' CURB, 100' RADIUS
PCC, TYPE 'D' CURB, 6'R/100'R BULLNOSE
¡ 6' S/W AT NEW GUARD HOUSE
23.00 LT
39.05 LT
15.50 LT
ON ¡
ON ¡
50 2+75.96 11.85 MP TYPE 'D' CURB 12'R ISLAND BULLNOSE
54 1+99.38 11.40
12.00 RT
MP TYPE 'D' CURB 6'R ISLAND BULLNOSE4.48 RT
PT, TYPE 'D' CURB, 12'R ISLAND BULLNOSE
11.28
¡ 5' S/W CURB RAMP FLOW LINE
L.P. C&G FLOW LINE, ¡ 3' CONC FLUME
L.P. C&G FLOW LINE, ¡ 3' CONC FLUME
PC C&G HIGH POINT, 160' RADIUS
52 2+66.00 11.36 POT C&G HIGH POINT14.00 LT
10.98
M.E.
11.16
11.00
M.E.
11.45
11.45
11.49
M.E.
9.46
M.E.
M.E.
M.E.
55 2+30.00 12.007.50 RT ¡ OF ENTRANCE SIGN AT FINISH GRADE
11.31
BEGIN M&R / C&G AT PC, MATCH EXIST.
PCC C&G, 50' RADIUS
END RUBBLE RIP-RAP
END CONC FLUME, BEGIN RUBBLE RIP-RAP
PT 3'R ISLAND BULLNOSE
PC 3'R ISLAND BULLNOSE
PT 3'R ISLAND BULLNOSE
PC 3'R ISLAND BULLNOSE
PT 3'R ISLAND BULLNOSE
PC 3'R ISLAND BULLNOSE
PT 3'R ISLAND BULLNOSE
PC 3'R ISLAND BULLNOSE
11.45
11.48
ON ¡
ON ¡2+97.79
M.E. END M&R / C&G AT PT 15'R, MATCH EXIST
11.21 PC, C&G, 15'R
END CONC. FLUME, BEGIN RUBBLE RIP-RAP
¡ PROP. GUARD HOUSE SLAB (FIN FLR EL)
RELATIVE TO GATE OPERATOR
POSITION FENCE CORNER
S C
A L E
N
W A T E R
W A T E R
WATER
WATER
WATER WATER
ARV
2+00 3+00 x
C P x
C P
1+00 +20 +40 +60 +80 2+00 +20 +40 +60 +80 3+00
.6
.6
.5
.5
.5
.5
.5
.4
.4
.3
.3
.4
.4
.4
.4
.4
.5
.5
.5
.5
.6
.5
.4
.3
E L E
V
.5
S
T A
.0
P
A V
E M
E N
T M
A T
C H
E
X
IS
T
B E
G
IN
L T
P
G L
L .P
E L E
V
.2
P
V I
S T
A
.0
H .P
E L E
V
.6
P
V I
S T
A
.0
E L E
V
.3
S
T A
.0
P
A V
E M
E N
T M
A T
C H
E
X
IS
T
E N
D
L T
P
G L
.5
.5
.4
.4
.4
.3
.3
.3
.2
.3
.4
.4
.5
.6
.6
.5
.5
.4
.4
.3
(+)0.65%(-)0.30% (-)0.49%
SEE TYPICAL SECTION
PROP. GRADE LINE (LT & RT)
+20 +40
ALONG � CONST.
EXIST. GROUND LINE
NO.
SHEET
PROJECT NAME
BOARD OF COUNTY COMMISSIONERS
COLLIER COUNTY
DATE
ADVANCE MOT CERT. NO. 28347
CERT. OF AUTH. NO. 32121
ADAM AHMAD, P.E. NO. 72472
PHONE: (239) 273-8894
9010 STRADA STELL CT, STE 108, NAPLES, FL 34109
CAPITAL CONSULTING SOLUTIONS CONSTRUCTION PLANS
3851 CITY GATE DRIVE, NAPLES, FL 34117
SOUTH COUNTY REGIONAL WTP
ENTRANCE IMPROVEMENTS
12-22-21 1 SHEET REVISIONS FOR SWING GATES.
4-1-22 2 C.L.F. & GATE/ARM REVISIONS.
REV. SEPT. 6, 2022
JAN. 24, 2022 8-16-22 3 PRIVACY WALL, ENTRANCE SIGN, C.L. FENCE & MINOR REV.
9-6-22 4 SOUTH SIDE REVISIONS.
8DETAIL SHEET
INTERSECTION
W H
IT
E L
A K
E B
L V
D
N
R/W LINE
R /W
L
IN
E
CITY GATE DRIVE
CITY GATE DRIVE
W H
IT
E L
A K
E B
L V
D
SCALE: 1"=10'R/W LINE
R /W
L
IN
E R /W
L
IN
E
CR-E
CR-D
� CONST
E
.7
N
.9
B
E G
IN
C
O N
S T
STA. 1+26.00
MATCH EXIST.
BEGIN CONST.
EXIST. POWER POLE
ADJACENT TO
BE CONSTRUCTED
PROP. SIDEWALK TO
TO BE REMOVED
SIDEWALK SIGN'
EXIST. 'END
TO BE RELOCATED
EXIST. MAILBOX
TO BE REMOVED
EXIST. STOP SIGN
BEHIND SIDEWALK
TO BE RELOCATED
EXIST. STOP SIGN
LAYOUT OF NEW IMPROVEMENTS.
SHEET NO. 6 FOR PROP.
NOTE: SEE ENTRANCE PLAN
10'
10'
10'
PAVEMENT MARKING
INSTALL 118LF OF 12" WHITE
PAVEMENT MARKING
INSTALL 170LF OF 12" WHITE
PAVEMENT MARKING
INSTALL 116LF OF 12" WHITE
W A T E R
W A T E R
WATER
WATER
WATER WATER
IRR
IRR
ARV
SAN
NPW
NPW
SAN
2+00 3+00 x
C P x
C P
NO.
SHEET
PROJECT NAME
BOARD OF COUNTY COMMISSIONERS
COLLIER COUNTY
DATE
ADVANCE MOT CERT. NO. 28347
CERT. OF AUTH. NO. 32121
ADAM AHMAD, P.E. NO. 72472
PHONE: (239) 273-8894
9010 STRADA STELL CT, STE 108, NAPLES, FL 34109
CAPITAL CONSULTING SOLUTIONS CONSTRUCTION PLANS
3851 CITY GATE DRIVE, NAPLES, FL 34117
SOUTH COUNTY REGIONAL WTP
ENTRANCE IMPROVEMENTS
12-22-21 1 SHEET REVISIONS FOR SWIING GATES.
4-1-22 2 C.L.F. & GATE/ARM REVISIONS.
REV. AUG. 16, 2022
JAN. 24, 2022
8-16-22 3 PRIVACY WALL, ENTRANCE SIGN, C.L. FENCE & MINOR REV.
11.53
11.50
11.41
11.36
11.44
11.69
11.56
11.53
11.61
11.41
C L
F
E N
C E
1+40
1+60
1+80
2+00
2+20 3+20
3+00
2+80
2+60
2+40
E X I S
T
P
P
£ Const.
£ Const. £ Const.
.5
.4
.3
.3
.3
.4
.6
.5
.4
.3
.3
.3
10203040 10 20 30 40 10203040 10 20 30 40
£ Const.
C L
F
E N
C E
C L
F
E N
C E
C L
F
E N
C E
.2
C L
F
E N
C E
C L
F
E N
C E
C L
F
E N
C E
C L
F
E N
C E
C L
F
E N
C E
C L
F
E N
C E
1:
1:
0.04
0.08 0.0
0.08
1:1
.4
0.02 0.02
0.02
:4
.6
0.02
HOUSE
GUARD
1:8
1:8 1:
1:
1:10
1:12
.4
GATE ISLAND
CROSS SECTIONS
NOT TO SCALENOT TO SCALE
NO.
SHEET
PROJECT NAME
BOARD OF COUNTY COMMISSIONERS
COLLIER COUNTY
DATE
ADVANCE MOT CERT. NO. 28347
CERT. OF AUTH. NO. 32121
ADAM AHMAD, P.E. NO. 72472
PHONE: (239) 273-8894
9010 STRADA STELL CT, STE 108, NAPLES, FL 34109
CAPITAL CONSULTING SOLUTIONS CONSTRUCTION PLANS
3851 CITY GATE DRIVE, NAPLES, FL 34117
SOUTH COUNTY REGIONAL WTP
ENTRANCE IMPROVEMENTS
12-22-21 1 SHEET REVISIONS FOR SWING GATES.
4-1-22 2 C.L.F. & GATE/ARM REVISIONS.
REV. SEPT. 6, 2022
JAN. 24, 2022 8-16-22 3 PRIVACY WALL, ENTRANCE SIGN, C.L. FENCE & MINOR REV.
9-6-22 4 SOUTH SIDE REVISIONS.
W A T E R
W A T E R
WATER
WATER
WATER WATER
IRR
IRR
ARV
SAN
NPW
NPW
SAN
1+00 2+00 3+00 x
C P x
C P
S C
A L E
N
UTILITY ADJUSTMENTS
R /W
L
IN
E
R/W LINE
R/W LINE
R /W
L
IN
E
CITY GATE DRIVE
W H
IT
E L
A K
E B
L V
D
£ CONST
STA. 3+22.00
MATCH EXIST.
END CONST.
(TO REMAIN)
EXIST. CCTV BOX
(TO REMAIN)
EXIST. METER BOX
(TO REMAIN)
EXIST. PULL BOX
(TO REMAIN)
EXIST. PULL BOX
(TO REMAIN)
EXIST. LIGHT POLE
(TO REMAIN)
EXIST. PULL BOX
(TO REMAIN)
EXIST. LIGHT POLE
(TO BE REMOVED)
EXIST. BOLLARDS
(TO REMAIN)
EXIST. PULL BOX
(TO REMAIN)
EXIST. METER BOX (TO BE ADJUSTED)
EXIST. PULL BOX
POLE (TO REMAIN)
NEW CAMERA
(TO BE REMOVED)
SECURITY GATE
EXIST. INBOUND
(TO BE REMOVED)
OLD CAMERA POLE
FROM LIME BLDG
EXIST. ELEC. RACEWAY
FOR MOTORS
EXIST. 120V
DESK
HOUSE
GUARD
TO EXIST. LIME BLDG
PROP. ELEC. RACEWAY
PROPOSED CONDUIT SCHEMATIC
- SPARE
- FIBER OPTIC
- FIBER OPTIC
- 120V ELECTRIC
FROM PROP. GUARDHOUSE
EXIST. 36" WM
EXIST. 20" WM
EXIST. 8" FM
EXIST. 4" FM
HEAD ELECTRIC
EXIST. OVER-
- CODE BLUE PHONE
- CAMERAS
- CARD READERS
FROM KEYPAD LOCATION
ENCLOSURE
NEMA TYPE N4X
STAINLESS STEEL
(TO BE RELOCATED)
EXIST. LIGHT POLE
AND BOLLARDS (TO BE PROTECTED)
EXIST. BACKFLOW PREVENTOR
(TO REMAIN)
EXIST. POWER POLE
(TO BE REMOVED)
EXIST. ENTR. SIGN
(TO BE REMOVED)
EXIST. UTIL. BOLLARDS
STA. 1+26.00
MATCH EXIST.
BEGIN CONST.
(TO BE ADJUSTED)
EXIST. MANHOLE
(TO BE RELOCATED)
EXIST. LIGHT POLE
STA 2+37.00 (40.00' RT)
RELOCATED LIGHT POLE LOCATION
STA 3+20.00 (33.00' RT)
RELOCATED LIGHT POLE LOCATION
DIRECTED BY COUNTY, TYP.)
(TO BE RELOCATED AS
EXIST. UTILITY PULL BOX
DIRECTED BY COUNTY, TYP.)
(TO BE RELOCATED AS
EXIST. ELECTRICAL PANEL
BY COUNTY PERSONNEL.
PROP. GUARD HOUSE AS DIRECTED
ISLAND TO BE RELOCATED BEHIND
EXIST. FIBER OPTICS WITHIN MEDIAN
NOTE:
STA. 20+34.00 (22' RT)
CAMERAS AND KEY PAD
CODE BLUE PHONE,
HOUSE AS DIRECTED BY COUNTY.
RELOCATED BEHIND PROP. GUARD
BOX WITHIN GRAVEL ISLAND TO BE
EXIST. FIBER OPTICS AND CONTROL
(TO REMAIN)
EXIST. OH
(TO REMAIN)
EXIST. E. BOX
OF PROP. GATE OPERATOR.
(TO BE RELOCATED) FOR INSTALL.
EXIST. LIGHT POLE AND F.O. BOX2
:3
:5
P
M
R E
V I S I O
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2021-22 SHEETINDEX
11/01/20 520-001 1 2
CURB AND GUTTER
Gutter Construction
Future Curb And
" Exp. Joint2
20' R Or As Shown On Plans
" R4
Standard Shoulder Line
Roadway Pavement
Circulating Specified In The Plans
Truck Apron Surface
2"
"R8
Adjacent Pavement
Same Slope As
Joint Seal
Concrete PavementPreformed Joint Filler
" Exp. Joint And2
" R4
Joint Seal" R4
Conc. Pavt.
Preformed Joint Filler
" Exp. Joint And2
Joint Seal
Conc. Pavt.
Preformed Joint Filler
" Exp. Joint And2
*Fit Driveway
Slope To
Flexible Pavt. & Base
Seal
Joint Concrete Barrier
Single-Slope
Face of
Preformed Joint Filler
" Exp. Joint And2
Adjacent Pavt.
Match Slope of
TYPE B
TYPE D
TYPE A
TYPE E
DROP CURB
SHOULDER GUTTER
SECTION CC
SECTION BB
SECTION AA
PLAN
TYPE RA
VALLEY GUTTER
CONCRETE CURB AND GUTTER
ROUNDABOUT CENTRAL ISLAND CONSTRUCTION
TRAFFIC BEARING SECTION FOR USE IN
A
A B
B
C
C
Curb And GutterValley Gutter
1'-10" 1'-2"
R
" R
3'-0"
M in
S t d
M in
S t d
R
5'-0"
8"
" 2
R 3
R
6" 1'-6" 1'-10" 1'-2"
R
6" 1'-10" 1'-2"
R
8"
3'-6"
R
M in
S t d
M in
S t d
1'-6"9"
R
R
43 3
R
2'-3"
1' 6" 2'
" R
R
3'-6"
9"
R
" R
R
2'-3"
" R
"R
6"
8"
"3
" R 3"
R
9"
16"
9" 7"
R
R
R
" R required between curbs and concrete pavement only, see Sheet 2.
shown. Expansion joint, preformed joint filler and joint seal are
For use adjacent to concrete or flexible pavement, concrete Note:
Earth Berm Shoulder Pavement pavement only, see Sheet 2.
joint filler and joint seal are required between curb & gutter and concrete usage adjacent to flexible pavement, see Sheet 2. Expansion joint, preformed
For use adjacent to concrete or flexible pavement. For details depicting circulating roadway pavement.
Rotate entire section so that gutter cross slope matches slope of adjacent � shall be 6", unless otherwise shown on plans.
match the cross slope of the adjacent pavement. The thickness of the lip
When used on high side of roadways, the cross slope of the gutter shall *
TYPE F
DROP CURB
6" 1'-6"
R
R
8"
2'-0"
R
" R
2'-0"
10" 1'-2"
R
M in
S t d
M in
S t d
Note: To be paid for as parent curb.
to flexible pavement, see Sheet 2.
For details depicting usage adjacent
" R
B a s e
M a t c h
P a v t
1'-0"
TOLL HEADER CURB
for conduit requirements)
(See the toll site details
:3
:5
P
M
R E
V I S I O
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2021-22 SHEETINDEX
11/01/17 520-001 2 2
CURB AND GUTTER
End Of Curb
Edge Of Pavt. Edge Of Pavt.
Top Of Curb
Gutter Gutter
Top Of Curb
End Of Curb
Edge Of Pavt. Edge Of Pavt.
Top Of Curb
Gutter
Top Of Curb
Gutter
" Min.2
Depth Of Sawcut
0" Min.
" Max.2
0" Min.
" Max.2
Depth Of Sawcut
Depth Of Sawcut
0" Min.
5" Max.
0" Min.
5" Max.
" Min.2
Depth Of Sawcut " Min.2
Depth Of Sawcut
" Min.2
Depth Of Sawcut
5" Max.
4" Min., 3" Max.
2" Min., Rubbed
Cast Or
R=2"
Pitch Optional
" Holes4 3" Or 8
(Two Per Guard)
#4 Bars, 18" Long
Curb Or Curb & Gutter.
On High Side To Be Flush With Lip Of
" Above Lip Of Gutter. Surface4 1Be
Surface On Low Side Of Pavement to
Slope Varies
Flexible Pavt.
Joint Seal �
Preformed Joint Filler �
" Exp. Joint And2
Pavement
ConcreteGutter
Concrete
PLANPLAN
PLANPLAN
PROFILE
FLARED END
PROFILE
STRAIGHT END
CURB TYPE A
PROFILE PROFILE
FLARED END STRAIGHT END
CURB AND GUTTER TYPES E & F
SHOULDER GUTTER TYPE E
TYPE F
TYPE A
TYPE B
TYPE D
GENERAL NOTES
CURB AND GUTTER ENDINGS
ADJACENT TO FLEXIBLE PAVEMENT
CURB AND GUTTER AND TYPE A CURB
CONTRACTION JOINT IN CURB
CONCRETE BUMPER GUARD ASPHALTIC CONCRETE CURB
CONTRACTION JOINT IN CURB AND GUTTER
AND CONCRETE PAVEMENT
EXPANSION JOINT BETWEEN GUTTER
Sawcuts should be avoided within valley gutter and within curb and gutter endings.
8.5'
R
Trans.
3'
Trans.
3'
5.5'
6'
3' Trans.
3'
Trans.
3'
V a r ie s
" R
R
"2
M in
M a x
9" Max.
8" Min., 3" Max.
2" Min.,12"(±)
6'-0"
2"5"2"
9"
Applies to shoulder gutter only where adjoining traffic lanes.
Applies to both high and low sides of pavement, low side shown.�
� Applies to both high and low sides of pavement, low side shown.
R
Ends of Curbs Types B and D shall transition from full to zero heights in 3'.2.
be located in accordance with Specification 520.
to exceed 10' centers. Curb, gutter and curb & gutter expansion joints shall and flat curves are to match the pavement joints, with intermediate joints not centers (max.). Contraction joints adjacent to concrete pavement on tangents
" contraction joints at 10' 4 1" - 8
1For curb, gutter and curb & gutter provide 1.
:3
:5
P
M
R E
V I S I O
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2021-22 SHEETINDEX
11/01/17
MEDIAN OPENING FLUME
520-010 1 1
CUSTOM CONC. FLUME DETAIL
6" For Type F Curb
7" For Type A Curb
SECTION CC
CC
Varies (4.75' Typ.)Varies (4.75' Typ.)
R
V a ri es
3'-0"
9" 1'-6" 9"
3' R
18" For Types E & F Curbs
3'-0"6" 6"
4'-0"
FLUME DETAIL
NOTE:
SEE ENTRANCE PLAN
SHEET FOR FLUME LENGTH
AND RIP-RAP QUANTITY.
Rod Leder Rectangle
Rod Leder Rectangle
Rod Leder Line
Back of Sidewalk Variations
A (Signal Pole or Controller Base. Ex.)
A A
A
A (Utility Pole, Ex.)
A
A
A
A (Signal Pole or Controller Base. Ex.)
A (Utility Pole, Ex.)
A A
A
Curb or Curb And Gutter
G G
Curb or Curb And Gutter
A
See Index 522-002 For Joints
PT
PT
See Index 522-002 for Joints
A
G
A
A
PT
A
A
Drainage Inlet
Drainage Inlet
A
Strip Utility
Sidewalk Sidewalk
Clear Width
9"
45°
Sidewalk
G
515-062, 515-070 or 515-080)
Railing (See Index 515-052, Return Curb
Return Curb
Rigid Structure
Rigid Structure
5' 5' 5' 5' 5' 5' 5' 5' 5' '2 1'2
'2
5' 5' 5' 5' 5' 5' 5' 5' 5' 5' '2
:4
:2
R E
V I S I O
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2021-22 SHEETINDEX
11/01/18
CONCRETE SIDEWALK
522-001 1 2
FDOT
STORM
SEWER
GENERAL NOTES AND CONCRETE SIDEWALK ON CURBED ROADWAYS
PLAN
SIDEWALK WITHOUT UTILITY STRIP
A
A
PLAN
B
B
SIDEWALK WITH UTILITY STRIP
LEGEND:
4" Thick Sidewalk
6" Thick Sidewalk
Utility Strip
(Full Return Shown)
Driveway or Side Road
(Partial Return Shown)
Driveway or Side Road
Driveway
Driveway
0.02 Max.0.02 Max.
0.02 Max.
Varies
SECTION A-A
(5' or 6' Std., 4' Min)
Varies Based on Railing Used
SECTION B-B RAILING DETAIL
VariesVaries
OPEN JOINTS
LONGITUDINAL SECTION
SAWED JOINTS
120' Max.
30' Max.30' Max. 30' Max.
A D D D D D E D D F D D A
A B C B C B C B C B A
120' Max.
SIDEWALK JOINTS
GENERAL NOTES:
LEGEND:
G- Cold Joint With Bond Breaker, Tooled the Engineer.
locations when called for in the plans or at locations as directed by
" Expansion Joint When Run Of Sidewalk Exceeds 120'. Intermediate 2 1F-
Joint(s) Required When Length Exceeds 30'
" Deep (within 12 hours) Max. 30' Centers2 1" Saw Cut Joints, 116
3E-
" Deep (within 96 hours) Max. 5' Centers2 1" Saw Cut Joints, 116
3D-
" Formed Open Joints8 1C-
" Dummy Joints, Tooled8 1B-
(e.g. drainage inlets and utility poles).
driveways, sidewalk-intersections, and all other fixed objects
" Expansion Joints (Preformed Joint Filler) between the sidewalk and;
1A-
Railing or Pipe Guiderail shown in the plans. (See RAILING DETAIL)
5. Construct sidewalks with Edge Beam through the limits of any surface mounted Pedestrian/Bicycle
1 having a thickness of not less than 6 mils and not more than
4. Bond breaker material can be any impermeable coated or sheet membrane or preformed material
3. For Driveways see Index 522-003.
2. Include detectable warnings on sidewalk curb ramps in accordance with Index 522-002.
thickness as shown, unless otherwise detailed in the Plans.
Curb Ramps Located within Curb Returns (See Plan View). Install all other concrete with
1. Construct sidewalks in accordance with Specification 522. Use 6" concrete for Sidewalks and
Flexible Pavt.
Rigid Pavt.
Flexible Pavt.
Rigid Pavt.
5'5'5'5'
5'5' 5' 5' 5'5'5'5' 5' 5'5'5'5'"
5'5'5'5' 5' 5' 5'
30' Max.
5'5' 5' 5' 5'5'5' 5' 5'5' 5' 5' 5'
30' Max.
Graded Driveway
Sidewalk
Edge of Travel Way
Shoulder Line
Shoulder Line
Edge of Travel Way
Warning Surface
2' Detectable
Warning Surface
2' Detectable
:4
:1
P
M
R E
V I S I O
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2021-22 SHEETINDEX
11/01/18
CONCRETE SIDEWALK
522-001 2 2
D D D D D E D
30' Max.
A D D D D D E D D F D D A D D E D D A
B C B C
A B C B C B C B C B A B C B C A
M in
LONGITUDINAL SECTION
OPEN JOINTS
SIDEWALK JOINTS
LEGEND:
SAWED JOINTS
M in
30' Max.
120' Max. 30' Max. 30' Max.120' Max.
the Engineer.
locations when called for in the plans or at locations as directed by
" Expansion Joint When Run Of Sidewalk Exceeds 120'. Intermediate
1F-
Joint(s) Required When Length Exceeds 30'
" Deep (within 12 hours) Max. 30' Centers
1" Saw Cut Joints, 1
3E-
" Deep (within 96 hours) Max. 5' Centers2 1" Saw Cut Joints, 116
3D-
" Formed Open Joints8 1C-
" Dummy Joints, Tooled8 1B-
(e.g. drainage inlets and utility poles).
driveways, sidewalk-intersections, and all other fixed objects
" Expansion Joints (Preformed Joint Filler) between the sidewalk and 2 1A-
Graded Driveway
SECTION C-C
0.02 Max.
Varies
CONTINUOUS SIDEWALK
DISCONTINUOUS SIDEWALK
PLAN
C
C
Border
PLAN
Driveway Side Road
C
C
Border
Driveway Side Road
LEGEND:
4" Thick Sidewalk
CONCRETE SIDEWALK ON FLUSH SHOULDER ROADWAYS
RA
P
Detectable Warnings Curb Transition
LAND
ING
SID
EW
ALK
SID
EW
ALK
STRIP
UTILITY
(Joints Permitted)
Slope Breaks
:4
:1
P
M
R E
V I S I O
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2021-22 SHEETINDEX
11/01/20
DETECTABLE WARNINGS AND SIDEWALK CURB RAMPS
522-002 1 7
Joints Not Permitted In Ramp
GENERAL NOTES:
CURB RAMP NOMENCLATURE
Transition Slope
T ransition S lope not required to be aligned.
truncated domes with the centerline of the ramp; otherwise, the truncated domes are
C. If detectable warnings are shown in the Plans on slopes greater than 5%, align the
5 feet from the back of the curb or edge of pavement.
minimum depth of 2 feet measured perpendicular to the curb line and no greater than
B. Place detectable warnings across the full width of the ramp or landing, to a
A. Install detectable warnings in accordance with Specification 527.
Detectable Warnings: 4.
B. Alpha-identifications CR-I and CR-J are intentionally omitted.
purposes in the Plans.
A. Sidewalk curb ramp alpha-identifications (e.g. CR-A) are provided for reference
Curb Ramp Alpha-Identification: 3.
curb transition or to the extent that no remaining section is less than 5 feet long.
B. Remove any existing curb, curb and gutter, or sidewalk to the nearest joint beyond the
A. Refer to Index 522-001 for concrete thickness and sidewalk details.
Curb, Curb and Gutter and/or Sidewalk: 2.
with Index 522-001. No joints are permitted within the ramp portion of the Curb Ramp.
D. Joints permitted at the location of Slope Breaks. Otherwise locate joints in accordance
Ramp slopes are not required to exceed 15 feet in length.
C. Maintain a single longitudinal slope along each side of the curb ramp.
B. Landings must have cross-slopes less than or equal to 0.02 in any direction.
where the requirements cannot be met.
are maximums. With approval of the Engineer, provide the minimum feasible slope
A. Sidewalk, ramp, and landing slopes (i.e. 0.02, 0.05, and 1:12) shown in this Index
Cross Slopes and Grades:1.
CR-E
PLAN VIEW
ISOMETRIC VIEW
CR-F CR-G
PLAN VIEW
ISOMETRIC VIEW
ISOMETRIC VIEW
PLAN VIEW
CR-D
.0
:1 a m p
0.02 m m p
0.02
.0
.0 m p
0.02
Sidewalk
Sidewalk Curb
2'-0" R
Landing
2'-0" R 2'-0" R
2'-0" R
Sidewalk
Sidewalk Curb
Sidewalk
Sidewalk Curb
2'-0"
G r a s s
O r
P a v t
U t il it y
S t r ip
Sidewalk Curb
Sidewalk
Ramp RampRamp
2'-0" Detectable Warnings2'-0" Detectable Warnings m p
2'-0" Detectable Warnings
ISOMETRIC VIEW
R a
U ti li ty S tr ip
U ti li ty S tr ip m p
R a m p
Ra mp
SIDEWALK CURB RAMPS CR-D, CR-E, CR-F & CR-G
2'-0" Detectable Warnings
Sidewalk
PLAN VIEW
Sidewalk
4'-0" Min.
M ax
M ax
5'-0" Min. 4'-0" Min. 4'-6" Min.
R a m p
5'-0" (Shown)
6'-0" (Shown) 6'-0" (Shown)
6'-0" (Shown)
:4
:2
P
M
R E
V I S I O
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2021-22 SHEETINDEX
11/01/20
DETECTABLE WARNINGS AND SIDEWALK CURB RAMPS
522-002 4 7
OPTION A
OPTION B
OPTION A
OPTION B
OPTION A
OPTION B
:4
:3
P
M
R E
V I S I O
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2021-22 SHEETINDEX
11/01/17
FENCE TYPE B
550-002 1 3
5 Per Bar Equally Spaced ≤ (15") " Tension Bands4
314 Ga. x
Corner
Tension Wire
Varies: 2' Max. 6" Min.
Rail (Brace)
Ties @ 2' CentersPost Cap
Ground Line
Ties @ 2' Centers
Ties @ 12" Centers
Tension Wire
Truss Rod
Bar Each Side
" Tension 4 3"x 16
At All Posts (Typical)
Above Ground
Crowned 1"
Concrete Base Ties @ 2' Centers Tension Wire
Tension Wire
Post Cap Ties @ 2' Centers Varies: 2' Max. 6" Min.
Truss Rod Bar Each Side
" Tension 4 3"x16
Rail (Brace) Ties @ 2' Centers
Spaced (≤ 15") Equally
5 Per Bar
Tension Bands, " 4 314 Ga. x
Ti es ' C en te rs
' M ax
' M ax
End
10' Max.10' Max.
(S t d
" 10"
12"
Note: Tubular Post Illustrated
Top And Bottom Selvage
2" Mesh, Twisted And Barbed
Chain Link Fabric No. 9 Gage
Bottom Selvage
Top and
And Barbed
Mesh, Twisted
No. 9 Gage 2"
Chain Link Fabric
10' Max. 10' Max.
" 10"
12"
GENERAL NOTES
LINE POST LINE POST
CORNER OR END POST
LINE POST
LINE POST
PULL POST
LINE POST
of Table 2, ASTM F1043.
thickness of 0.0003" min.; internal and external coatings are not restricted to the combinations
Type B shall have a thickness of 15µg/in². min. and the polymer film topcoat shall have a
C or D and external coating Types A, B, or C; the chromate conversion coating of external thick. and min. wt. 3.117 lb./ft.; with ASTM F1043 metric equivalent internal coating Types A, B, " OD, 2" NPS, 2.375" dec. equiv., 0.130"min. wall2 1 (Alternative Design); fence industry 2 or undepleted stock of discontinued A446/A446M base materials; ASTM F669 Group IV
(4) Resistance welded steel pipe; 50,000 psi min. yield strength ASTM A569/A569M, A653/A653M
" nominal dia.: ASTM B241 or B221, Alloy 6063,T6.2 1 (3) Aluminum alloy pipe- 2
2.375" OD; coated at the rate 0.40 oz./ft.: AASHTO M111.
(2) Aluminum coated steel pipe: ASTM A53 steel, X 2 Tables: Schedule 40; 2" nominal dia., ASTM A53 Table X 2, ASTM F1083, and AASHTO M111.
(1) Galvanized steel pipe, Schedule 40- 2" nominal dia. zinc galvanized at the rate of 1.8 oz./ft².:
B. Corner, end, and pull post options:
of Table 2, ASTM F1043.
thickness of 0.0003" min.; internal and external coatings are not restricted to the combinations
Type B shall have a thickness of 15µg/in². min. and the polymer film topcoat shall have a
B, C or D and external coating Types A, B, or C; the chromate conversion coating of external thick. and min. wt. 2.28 lb./ft.; with ASTM F1043 metric equivalent internal coating Types A, " NPS, 1.900" dec. equiv., 0.120" min. wall2 1 (Alternative Design); fence industry 2" OD, 1 or undepleted stock of discontinued A446/A446M base materials; ASTM F669 Group IV
(7) Resistance welded steel pipe; 50,000 psi min. yield strength ASTM A569/A569M, A653/A653M mischmetal: ASTM F1043 and Detail.
": Galv.: 1.8 oz/ft. zinc: AASHTO M111; OR , 0.9 oz./ft². zinc-5% aluminum-8 5"X 18
7 (6) Steel C- 1
" Detail.8 5"X 18
7 (5) Aluminum alloy H-Beam- 1
": Zinc Galv. 1.8 oz./ft.: AASHTO M111 and Detail.8 5"x 18
7 (4) Steel H-Beam- 1
(3) Aluminum alloy pipe- 2" nominal dia.: ASTM B241 or B221, Alloy 6063, T6.
coated at the rate 0.40 oz./ft.: AASHTO M111.
" nominal dia., 1.90" OD; 2 1 (2) Aluminum coated steel pipe: ASTM A53, Table 2 (Grade A or B): Schedule 40- 1
ASTM A53 Table 2 (Grade A or B), ASTM F1083, and AASHTO M111.
" nominal dia. zinc galvanized at the rate of 1.8 oz./ft².:2 1 (1) Galvanized steel pipe, Schedule 40- 1
A. Line post options:
Fence Component Options:4.
fittings and hardware shall meet the requirements of AASHTO and ASTM signify current reference.
Chain link fabric, post, truss rods, tension wires, tie wires, stretcher bars, gates and all miscellaneous3.
For supplemental information refer to Specification 550.2.
This fence to be used generally in urban areas.1.
(3) Aluminum coated steel wire No. 7 gage coated at the rate of 0.040 oz./ft².
ASTM B211, Alloy 5056 Temper H38, or, Alclad Alloy 5056 Temper H192.
(2) Aluminum alloy wire with a diameter of 0.1443" or larger conforming to the requirements of
(1) Steel wire No.9 gage zinc galvanized at the rate of 1.2 oz./ft².
F. Tie wire and hog ring options:
(3) Aluminum coated steel wire No.7 gage coated at the rate of 0.040 oz./ft².: AASHTO M181.
of ASTM B211, Alloy 5056 Temper H38, or, Alclad Alloy 5056 Temper H192.
(2) Aluminum alloy wire with a diameter of 0.1875" or larger conforming to the requirements
(1) Steel wire No. 7 gage zinc galvanized at the rate of 1.2 oz./ft².: AASHTO M181.
E. Tension wire options:
No. 36622 of Federal Standard 595a.
colors medium green, dark green or black the coating color shall be soft gray matching that of and bonded) or Class B (bonded). See table right. Unless the plans call for M181 standard diameter), core wire-zinc coated steel. PVC coating: M181 Class A (either extruded or extruded
(3) AASHTO M181 Type IV- Polyvinyl Chloride (PVC) Coated Steel, No. 9 gage (coated core wire at the rate of 0.40 oz./ft².
(2) AASHTO M181 Type II -Aluminum Coated Steel, No. 9 gage (coated wire diameter), coated rate of 1.8 oz/ft². (M181 Class D 2.0 oz./ft². modified to 1.8 oz./ft².).
(1) AASHTO M181 Type I - Zinc Coated Steel, No. 9 gage (coated wire diameter), coated at the except as described in Note 10):
D. Chain link fabric options (2" mesh with twisted and barbed selvage top and bottom for all options
ASTM F1043.
0.0003" min.; internal and external coatings are not restricted to the combinations of Table 2, shall have a thickness of 15µg/in². min. and the polymer film topcoat shall have a thickness of
D and external coating Types A, B, or C; the chromate conversion coating of external Type B and min. wt. 1.836 lb./ft.; with ASTM F1043 metric equivalent internal coating Types A, B, C or
" NPS, 1.660" dec. equiv., 0.111" min. wall thick.4
1" OD, 18
5 (Alternative Design); fence industry 1 or undepleted stock of discontinued A446/A446M base materials; ASTM F669 Group IV
(4) Resistance welded steel pipe; 50,000 psi min. yield strength ASTM A569/A569M, A653/A653M
" nominal dia.: ASTM B241 or B221, Alloy 6063, T6.4 1 (3) Aluminum alloy pipe- 1
1.660" OD; coated at the rate 0.40 oz./ft.: AASHTO M111.
" nominal dia.,4 1 (2) Aluminum coated steel pipe; ASTM A53 steel, X 2 Tables Schedule 40; 1
ASTM A53 Table X 2, ASTM F1083, and AASHTO M111.
" nominal dia. zinc galvanized at the rate of 1.8 oz./ft².:4 1 (1) Galvanized steel pipe, Schedule 40- 1
C. Rail options:
:4
:4
P
M
R E
V I S I O
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2021-22 SHEETINDEX
11/01/17
FENCE TYPE B
550-002 2 3
TYPE IV VINYL COATED FABRIC
AASHTO M181 Table 4 Redefined As Follows
PVC Thickness Range
(Bonded Coating)
M181 Class BOf Zinc Coating
Minimum Weight
Core Wire
Of Metallic Coated
Specified Diameter
in. mm gage oz./ft². g/m² in. mm in. mm
0.25 to
0.15
0.010 to
0.006
0.64 to
0.38
0.025 to
0.015
920.3093.770.148
And Bonded Coating)
(Extruded Or Extruded
M181 Class A
DESIGN NOTE
GENERAL NOTES CONTINUED
in the Contract plans.
For fencing of different height or installation details, the fence shall be fully detailed height and with specific ground clearance.
This index details fencing that is constructed with chain link fabric 6' (nominal) in the fabric may be installed on the inside of the posts..
In areas where there are physical constraints outside the right-of-way which restricts the fence construction,13.
one brace, one truss rod and all necessary fittings and hardware as detailed.
rods, and all necessary fittings and hardware as detailed. End post assemblies shall consist of one end post, For construction purposes corner post assemblies shall consist of one corner post, two braces, two truss12.
posts at the opening. Gates shall be paid for under the contract unit price for Fence Gates, EA.
gates, single or double, all necessary hardware for installation and any additional length and/or size for meeting the material requirements described and as approved by the Engineer. Payment shall include the
Unless sliding gates or special gates are called for in the plans, all gates shall be chain link swing gates11.
be used unless the plans specifically identify locations for twisted selvage fabrics.
When fence has an installed top of fabric height less than 6' knuckled top and bottom selvages shall10.
breaks over 15° as determined by the Engineer.
Corner post are to be installed at all horizontal breaks in fence at 15° or more and as required at vertical9.
greater than 3°.
except that this maximum interval may be reduced by the Engineer on curves where the curve is
Pull post shall be used at breaks in vertical grades of 15° or more, or at approximately 350' centers8.
clearance, shall be set an additional 3" in depth for each 1' of of additional ground clearance.
Line and assembly posts for 6' fence which must be lengthened due to a variation in the normal ground base plate or by embedment as prescribed under (b) above for line post.
solid rock. Post within assemblies that are located on concrete structures or solid rock shall be set by
End, pull and corner post assemblies shall be in concrete as detailed above for all soil conditions other than in accordance with ASTM F567 Subsection 5.5.
plate detail "Fence Mounting On Concrete Endwalls And Retaining Wall", Sheet 3; or, by embedment
(c) Post mounted on concrete structure or solid rock shall be mounted in accordance with the base
Line post installed in accordance with Section 5.8 shall be 9'-6" long.
(b) In accordance with ASTM F567 Subsections 5.4 through 5.10 as approved by the Engineer.
Specifications.
(a) In accordance with special details and/or as specifically described in the Contract Plans and by the following methods:
Line post shall be 8'-6" long (Standard). Line post are to be set in concrete as described above or 7.
Class NS concrete may be proportioned by volume and/or by weight.
or a packaged, dry material meeting the requirements of a concrete under ASTM C-387. Materials for
Concrete for bases shall be Class NS concrete as specified in Specification 347 6.
optional material between any set of corner and/or end post assemblies.
or the corner and end post assembly optional material; but, pull post assemblies shall be the same
(c) Pull post assemblies shall be optional materials identical to either the line post optional material
(b) Only one line post optional material will be permitted between corner and/or end post assemblies.
(a) Only one fabric optional material will be permitted between corner and/or end post assemblies.
Combinations of optional materials are restricted as follows:
type of material or a combination of material types from the component options listed in note 4.
Unless a specific material is called for in the plans the Contractor may elect to use either a single5.
:4
:4
P
M
R E
V I S I O
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2021-22 SHEETINDEX
11/01/17
FENCE TYPE B
550-002 3 3
Plans (See Notes)
Otherwise Called For In
Restraint Side Unless
Fence To Be Mounted On
Post
R/W Line
In Plans
6" Or As Indicated
Wire Fabric
0.562"
" R Typ.4
0.562"
" R Typ.4
� Fence And Wall
" ℅ Alloy 6061-T62 1Aluminum
" ℅ (ASTM A36) Galvanized or2 1Steel
Post
Nuts And Washers (2 Reqd.)
"Anchors,4 3" Dia. Hole For 8
� Fence And Wall
(4 Reqd.)
Nuts And Washers
" Galvanized Anchors,2
" Dia. Hole For16
Post
" ℅ Alloy 6061-T68 3Aluminum
" ℅ (ASTM A36) Galvanized or8 3Steel
N o m
N o m
N o m
45° of posts and to exclude moisture in posts with tubular sections.
The cap-arm shall be designed to provide a drive fit over the top
(e.) Inward on pedestrian ways.
canals, borrow areas and similar support facilities.
(d.) Outward from lateral ditches, outfalls, retention basins, within highway right of way.
(c.) Outward from utilities and hazardous facilities located
(b.) Outward on controlled access right of way line.
(a.) Outward on limited access right of way line.
called for in plans, direction of restraint will be as follows:
Attachments to extend in direction of restraint. Unless otherwise
Attachments to be used only when called for in the plans.
Private Property
1.625"
.7
.8
0.105"
.7
1.625"
.8
0.121"
Yield PSI (Min.) 45,000
Galv. Wt. Per. Ft.= 2.34# ±5%
Yield PSI (Min.) 45,000
Galv. Wt. Per. Ft.= 1.85# ±5%
.2
.1
" "16
1"± 8
0.113"
" R32
.4
.6
.1
.2
Yielding Point (psi Min.)
Tensile Strength (psi Min.)
Surface Area (SF/Ft.)
Weight (Lb./Ft.)
Area (Sq. In.)
Rad. Of Gyration
Section Modulus
Moment Of Inertia
0.456 0.124
0.428 0.101
0.779 0.373
1-1 2-2
Axes
1-1 2-2
0.428 0.101
0.456 0.124
0.779 0.373
25,000
30,000
0.776
0.91 ± 5%
48,000
80,000
0.776
2.72 ± 5% (Galv.)
STEEL ALUMINUM
Axes
"4 11 "2
4"
8"As Adjacent Side
Dimensions Same
1"
BARB WIRE ATTACHMENT
NOTES
WITHOUT FRONTAGE ROADS
FENCE POSITION AT LOCATIONS
OPTIONAL "C" LINE POST
" H-BEAM LINE POST8
5"x 18
7OPTIONAL 1
FOUR ANCHOR PLATE OPTION
TOP VIEW
TWO ANCHOR PLATE OPTION
TOP VIEW
THINWALLSTANDARD WALL
FENCE MOUNTING ON CONCRETE ENDWALL AND RETAINING WALLS
LOCATIONS WITH FRONTAGE ROADS)
(REFER TO DETAIL PLANS FOR FENCE POSITION AT
Expansion Bolts Not Permitted.
larger in…