22-119 BD Dwgs.pdf

PDF 17 MB Posted

Attached to
Z2DA--Project No. 539-23-203 - Upgrade Elevators Federal contract opportunity
Solicitation number
36C25023B0055
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

About this file

This document provides details on a federal solicitation and related technical file. The solicitation number 36C25023B0055 from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10 is seeking proposals for the Z2DA--Project No. 539-23-203 job to upgrade elevators. The related technical file 22-119 BD Dwgs.pdf presumably contains drawings or specifications relevant to the elevator upgrade project. The solicitation is for an opportunity to provide upgrade services to elevators at a Veterans Affairs facility. Interested parties should review the solicitation and technical file for details on response requirements and dates as well as the scope of work involved in upgrading the elevators.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DA--Project No. 539-23-203 - Upgrade Elevators, newest first.
File Type Posted
36C25023B0055 0002.docx DOCX document
36C25023B0055 0001.docx DOCX document
Attachment lll - RFI Attachment.docx DOCX document
Attachment l - DBA WD.pdf PDF
Attachment IV - Limitations on Subcontracting.pdf PDF
22-119 BD Specs_.pdf PDF
vha directive 1192.01.pdf PDF
Attachment II - EMR Attachment.docx DOCX document
36C25023B0055_1.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TRAILERS

BLDG 16

BLDG 14

BLDG 15

BLDG 1

PARKING GARAGE

BLDG 8

BLDG 2

BLDG 3

# ALTERNATE NOTES

BID DEDUCT ALTERNATES:

BID ITEM 1 - GENERAL CONSTRUCTION: BASE BID: WORK INCLUDES GENERAL CONSTRUCTION, ALTERATIONS, AND CERTAIN OTHER ITEMS.

BID ITEM II: ALL ITEMS IN BID ITEM I EXCEPT WORK IN P15 & P16.

BID ITEM III: ALL ITEMS IN BID ITEM II EXCEPT WORK IN P7.

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

PROJECT SITE MAP - CINCINNATI VAMC PROJECT LOCATION MAP

Headquarters:

Michael Blades & Associates, Ltd.

5409 Rapidan Ct, Lothian, MD 20711 www.elevatormba.com 410-798-8504© 2020 Michael Blades & Associates, Ltd.

/2

/2

:4

:0

P

M C

U s e rs

\b n e e d h a m

\D o c u m e n ts \A

-1

-V

A C in c in n a ti -E le v a to r

U p g r E le v -O

H b n e e d h a m

H L

.r v t

G-001

COVER

1 2BN

UPGRADE ELEVATORS

CINCINNATI VA MEDICAL CENTER

3200 VINE STREET

CINCINNATI, OH, 45220 MARCH 17, 2023

BID DOCUMENTS

539-23-20322-119

UPGRADE ELEVATORS

CINCINNATI VA MEDICAL CENTER

3200 VINE STREET

CINCINNATI, OH, 45220

VA PROJECT #: 539-23-203

JAB

DRAWING LIST

GENERAL

G-001 COVER 1 2

G-002 SITE LOGISTICS PLAN 2 2

ARCHITECTURAL

A-001 ARCHITECTURAL SYMBOLS, ABBREVIATIONS AND NOTES 1 8

A-100 OVERALL BUILDING 1 GROUND FLOOR PLAN 2 8

A-101 BUILDING 1 TYPICAL PASSENGER (P-1 THRU P-4) ELEVATOR CAB PLANS AND INTERIOR ELEVATIONS 3 8

A-102 BUILDING 1 TYPICAL SERVICE (S-5 / S-6) ELEVATOR CAB PLANS AND INTERIOR ELEVATIONS 4 8

A-103 BUILDING 1 TYPICAL PASSENGER (P-9) ELEVATOR CAB PLANS AND INTERIOR ELEVATIONS 5 8

A-104 BUILDING 1 TYPICAL PASSENGER (P-15 / P-16) ELEVATOR CAB PLANS AND INTERIOR ELEVATIONS 6 8

A-105 OVERALL BUILDING 15 GROUND FLOOR PLAN 7 8

A-106 BUILDING 15 PASSENGER ELEVATOR P-7 ENLARGED FLOOR PLAN AND INTERIOR ELEVATIONS 8 8

ELECTRICAL

E-001 ELECTRICAL GENERAL NOTES, SYMBOL LEGENDS, AND ABBREVIATIONS 1 3

E-101 BUILDING 1 ELEVATOR PLANS 2 3

E-501 ELECTRICAL DETAILS 3 3

N

N

CINCINNATI VA MEDICAL CENTER

1, 15

DocuSign Envelope ID: 9289DCDD-F08B-4787-993B-592F5DB92B7D

3/29/2023

TRAILERS

PARKING GARAGE

VINE ST.

G O

O D

M A

N S

T

E S

H

IE

L D

S S

T

FISHER

HOUSE

RESEARCH

TRAILERS EDUCATION, SAFETY,

RESEARCH, OEF/OIF

FISHER HOUSE

RESEARCH

RESEARCH

BOILER PLANT

ADMIN (ENGINEERING/

LOGISTICS)

CLC, REHAB CARE LINE,

ADMIN

MAIN HOSPITAL

INDICATES BLDGS WITH

ELEVATORS IN SCOPE

OF WORK

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

Headquarters:

Michael Blades & Associates, Ltd.

5409 Rapidan Ct, Lothian, MD 20711 www.elevatormba.com 410-798-8504© 2020 Michael Blades & Associates, Ltd.

/2

/2

:4

:0

P

M C

U s e rs

\b n e e d h a m

\D o c u m e n ts \A

-1

-V

A C in c in n a ti -E le v a to r

U p g r E le v -O

H b n e e d h a m

H L

.r v t

G-002

SITE LOGISTICS PLAN

2 2BN

UPGRADE ELEVATORS

CINCINNATI VA MEDICAL CENTER

3200 VINE STREET

CINCINNATI, OH, 45220 MARCH 17, 2023

BID DOCUMENTS

539-23-20322-119

JAB

Scale: No Scale

SITE LOGISTICS PLAN

LOGISTICS PLAN LEGEND

N O

R T

H

1, 15

AFF ABOVE FINISHED FLOOR

ACP/APC ACOUSTIC CEILING PANEL/

ACOUSTIC PANEL CEILING

ACT ACOUSTIC(AL) TILE

ADJ ADJUSTABLE

ADT'L ADDITIONAL

AGG AGGREGATE

ALT ALTERNATE

AL ALUMINUM

APPROX APPROXIMATE(LY)

ASPH ASPHALT

AUTO AUTOMATIC

B/O BOTTOM OF

BD BOARD

BLDG BUILDING

BLKG BLOCKING

BOT BOTTOM

BRG BEARING

CENTERLINE

C/C CENTER TO CENTER

CJ CONTROL JOINT

CLL CONTRACT LIMIT LINE

CEM CEMENT(ITIOUS)

CMU CONCRETE MASONRY UNIT

CLG CEILING

CLR CLEAR

COL COLUMN

CONC CONCRETE

CONST CONSTRUCTION

CONT CONTINUOUS

CPT CARPET

CT CERAMIC TILE

CTR CENTER(ED)

DF DRINKING FOUNTAIN

DS DOWNSPOUT

DBL DOUBLE

DEG DEGREE

DEMO DEMOLITION

DET/DTL DETAIL

DIA DIAMETER

DIM DIMENSION

DN DOWN

DWG(S) DRAWING(S)

E EAST

EC ELECTRICAL CONTRACTOR

EHO ELECTRICAL HOLD OPEN

EJ EXPANSION JOINT

EW EACH WAY

EA EACH

EIFS EXTERIOR INSULATION

FINISH SYSTEM

EL ELEVATION

ELEC ELECTRIC(AL)

ELEV ELEVATOR

EMER EMERGENCY

EQ EQUAL

EQUIP EQUIPMENT

EXIST EXISTING

EXT EXTERIOR

EWC ELECTRIC WATER COOLER

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FFE FINISH FLOOR ELEVATION

FV FIELD VERIFY

FEC FIRE EXTINGUISHER CABINET

FDN FOUNDATION

FIN FINISH

FLSHG FLASHING

FLR FLOOR

FRMG FRAMING

FT FOOT/FEET

FTG FOOTING

GC GENERAL CONTRACTOR

GA GAUGE

GALV GALVANIZED

GEN GENERAL

GYP GYPSUM

HM HOLLOW METAL

HDWR HARDWARE

HOL HOLLOW

HOR HORIZONTAL

HT HEIGHT

HVAC HEATING/VENTILATION/AIR

CONDITIONING

ID INSIDE DIAMETER

IN INCH

INCL INCLUDING

INSUL INSULATION

INT INTERIOR

JAN JANITOR

JT JOINT

LAV LAVATORY

LB(S) POUND(S)

L/S LANDSCAPE

LT LIGHT

MO MASONRY OPENING

MAS MASONRY

MAT'L MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MTD MOUNTED

MTL METAL

N NORTH

NIC NOT IN CONTRACT

NTS NOT TO SCALE

NOM NOMINAL

OC ON CENTER

OD OUTSIDE DIAMETER

O TO O OUT TO OUT

OPNG OPENING

OPP OPPOSITE

OVHD OVERHEAD

PEB PRE-ENGINEERED BUILDING

PJF PREFORMED JOINT FILLER

PT PRESSURE TREATED

PERIM PERIMETER

PL PLATE

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PLYWD PLYWOOD

PNT PAINT

PR PAIR

PTD PAINTED

PWR POWER

RB RUBBER BASE

RD ROOF DRAIN

RO ROUGH OPENING

RAD RADIUS

REC RECESSED

REINF REINFORCED

REQ'D REQUIRED

REV REVISED (REVISION)

RM ROOM

S SOUTH

SB SPLASH BLOCK

SF SQUARE FEET

SS STAINLESS STEEL

SIM SIMILAR

SPEC SPECIFICATIONS

SQ SQUARE

STD STANDARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

SUSP SUSPENDED

T&G TONGUE AND GROOVE

T/O TOP OF

TELE TELEPHONE

THRU THROUGH

TRTD TREATED

TS TUBE STEEL

TYP TYPICAL

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

VCT VINYL COMPOSITION TILE

VIF VERIFY IN FIELD

VERT VERTICAL

W WEST

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WWF WELDED WIRE FABRIC

WD WOOD

WH WATER HEATER

WT WEIGHT

CL

1. INDICATIONS OF PROJECT LIMITS OR LINES OF DEMARCATION ARE SHOWN

FOR GENERAL SCOPE DEFINITION AND REFLECT THE UNDERSTANDING OF

THE DESIGNER AS TO THE LIMITATIONS OF THE WORK AREA IN AN OCCUPIED

AREA. ACTUAL CONTRACT LIMITS ARE TO BE DETERMINED BY AGREEMENT

BETWEEN THE COR AND CONTRACTOR BEFORE THE START OF THE WORK.

2. DRAWINGS ARE PREPARED USING PRODUCT DIMENSIONS AND DETAILS

FROM BASIS OF DESIGN PRODUCT. PRODUCTS MAY CHANGE IN DIMENSION

AND DETAIL BEFORE THEY ARE INCORPORATED INTO WORK. PRODUCTS

FROM OTHER MANUFACTURER’S ARE ALSO ACCEPTABLE. DIMENSIONS AND

DETAILS FOR ALTERNATE PRODUCTS MAY VARY FROM BASIS OF DESIGN.

CONTRACTOR SHALL VERIFY INSTALLATION REQUIREMENTS FOR ALL

PRODUCTS TO BE INCORPORATED INTO WORK (INCLUDING THICKNESS FOR

RECESSED OR SEMI-RECESSED PRODUCTS) AND IS RESPONSIBLE FOR

ACCOMMODATING AND COORDINATING CHANGES TO OTHER MATERIALS OR

PRODUCTS THAT ARE NECESSARY BECAUSE OF THESE DIFFERENCES.

3. THE DRAWINGS AND SPECIFICATIONS ARE SEPARATED INTO DISCIPLINES

FOR CONVENIENCE. THE SEPARATIONS ARE USED ONLY FOR THE PURPOSES

OF CONVENIENCE AND REFERENCE AND IN NO WAY DO THEY DEFINE OR

LIMIT THE SCOPE OR INTENT OF ANY PART OF THE DRAWINGS AND

SPECIFICATIONS AS A WHOLE. THE FACT THAT THE DRAWINGS ARE

SEPARATED IN NO WAY SUGGESTS THAT THE WORK IS NOT TO BE

CONSTRUCTED AS A COMPLETE, INTEGRATED AND UNIFIED WHOLE.

4. THE DRAWINGS AND SPECIFICATIONS, INCLUDING DRAWINGS PREPARED BY

SPECIFIC ENGINEERING DISCIPLINES ARE COMPLEMENTARY; ITEMS SHOWN

IN ANY ONE LOCATION IN THE DRAWINGS SHALL BE CONSIDERED TO BE

REQUIREMENTS OF THE CONTRACT FOR CONSTRUCTION. IN THE EVENT OF

AN INCONSISTENCY BETWEEN THE DRAWINGS AND SPECIFICATIONS, OR

WITHIN EITHER DOCUMENT, THE CONTRACTOR SHALL SEEK CLARIFICATION

OR INTERPRETATION FROM THE COR PRIOR TO BIDDING. WHERE

INCONSISTENCIES ARE NOT CLARIFIED PRIOR TO BIDDING, AND WHERE THE

ACTUAL SOLUTION OR INTENT CANNOT BE REASONABLY INFERRED, THE

CONTRACTOR SHALL PROVIDE THE BETTER QUALITY OR GREATER QUANTITY

OF WORK.

5. THE CONTRACTOR SHALL NOTIFY THE COR IMMEDIATELY SHOULD

DISCREPANCIES BE FOUND IN THE DRAWINGS AND SPECIFICATIONS.

6. THE CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL FIELD CONDITIONS

AND DIMENSIONS AS THEY RELATE TO THIS PROJECT, FOR EACH PHASE.

SHOULD DISCREPANCIES EXIST BETWEEN THE WORK INDICATED AND

ACTUAL FIELD CONDITIONS, NOTIFY THE COR PRIOR TO PROCEEDING WITH

THE WORK.

7. DO NOT SCALE THE DRAWINGS. DRAWING SCALES AS INDICATED ARE FOR

REFERENCE ONLY AND ARE NOT INTENDED TO ACCURATELY DEPICT ACTUAL

OR DESIGNATED CONDITIONS. WRITTEN DIMENSIONS SHALL GOVERN.

8. PROVIDE SEALANT AT ALL INTERSECTIONS BETWEEN DIFFERENT MATERIALS.

9. COORDINATE WORK OF ALL TRADES PRIOR TO STARTING CONSTRUCTION.

10. REFER TO ALL OTHER TRADE DRAWINGS AND SPECIFICATIONS FOR

ADDITIONAL INFORMATION ON THIS PROJECT.

11. ALL ELEVATOR SUBMITTALS TO BE REVIEWED & APPROVED PRIOR TO

MOBILIZATION.

12. COMPLETE ONE ELEVATOR CAB BEFORE STARTING ANOTHER.

13. FINAL ELEVATOR EQUIPMENT PLANS WILL BE DESIGNED BY ELEVATOR

CONTRACTOR.

14. THE CONTRACTOR AND SUBCONTRACTORS INVOLVED IN THIS PROJECT

SHALL BE RESPONSIBLE FOR INSTALLING THEIR RESPECTIVE WORK AND

SYSTEMS TO MEET ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES,

LAWS, SAFETY REGULATIONS, HAZARDOUS WASTE LAWS, ETC. THE

CONTRACTOR SHALL FURNISH ALL NECESSARY PERMITS.

15. ALL WORK SHALL BE PERFORMED IN A SKILLED WORKMANSHIP TYPE

MANNER AND ACCEPTABLE TO THE COR'S.

16. CONTRACTOR IS RESPONSIBLE FOR ALL SERVICE CALLS AND SERVICES FOR

ALL 10 ELEVATORS AFTER THE EXECUTION AND DURING THE DURATION OF

THEIR CONTRACT.

1. KEY NOTES AND DRAWINGS ARE INTENDED TO GRAPHICALLY REPRESENT

GENERAL WORK AND DO NOT PORTRAY FULL SCOPE OF THE PROJECT. SEE

SPECIFICATIONS FOR DETAILED REQUIREMENTS.

2. REMOVE EXISTING CONSTRUCTION AS DESIGNATED HEREIN AND CLEAR

AREA OF DEBRIS PRIOR TO PROCEEDING WITH NEW CONSTRUCTION.

3. EXISTING EQUIPMENT REMOVED SHALL BE PROPERLY DISPOSED OF, OFF

PROJECT GROUNDS. COORDINATE WITH COR.

4. AT AREAS INDICATED TO BE PATCHED AND REPAIRED, FOR ADDITION AND

RENOVATION PROJECTS: THE CONSTRUCTION AND ASSEMBLY OF THE

PATCH OR REPAIR SHALL MATCH THE ASSEMBLY AND INTEGRITY OF THE

ADJACENT EXISTING CONSTRUCTION, FOR FIRE RATING, MATERIALS, FINISH,

THICKNESS, AND QUALITY.

5. COORDINATE WORKING HOURS ALLOWED FOR DEMOLITION AND WASTE

REMOVAL WITH COR.

6. NOTIFY COR OF ANY DEMOLITION REQUIRED AND NOT INDICATED FOR

INSTALLATION OF ELECTRICAL OR DATA ITEMS. AFTER SUCH DEMOLITION

AND INSTALLATION, PATCH OR REPLACE MATERIALS AND FINISHES TO

MATCH EXISTING.

7. CONTRACTOR SHALL PROTECT AREA ADJACENT TO THE DEMOTION AND

NEW CONSTRUCTION WORK TO PREVENT DAMAGES, (IF DAMAGED REPAIR,

RE-PATCH, SAND SMOOTH AND REFINISH TO MATCH EXISTING.) REPAIR OR

REPLACE ITEMS DAMAGED DURING CONSTRUCTION ACTIVITIES AT NO

ADDITIONAL COST.

8. THE INFORMATION CONTAINED IN THESE DEMOLITION DOCUMENTS DEFINES

GENERAL SCOPE ONLY AND DOES NOT RELIEVE THE CONTRACTOR OF THE

RESPONSIBILITY OF PROVIDING ALL DEMOLITION REQUIRED FOR THE

COMPLETION OF THE PROJECT.

9. DO NOT ENCROACH ON ADJACENT OCCUPIED AREAS NOT IDENTIFIED WITHIN

THE SCOPE OF WORK.

10. REFER TO THE ELECTRICAL DRAWINGS FOR FURTHER INFORMATION

REGARDING DEMOLITION OF ELECTRICAL SYSTEMS.

11. BEFORE THE START OF WORK, IDENTIFY ANY REQUIRED DEMOLITION

BEYOND THE IDENTIFIED PROJECT SCOPE WHETHER ABOVE, BELOW, OR

OUTSIDE THE PROJECT AREA. NOTIFY AND COORDINATE WITH THE COR,

PROVIDE DEMOLITION OF THESE AREAS AND PATCH THE SAME AS A PART OF

THE SCOPE OF THE PROJECT.

12. ALL DEMOLITION WORK SHALL BE PERFORMED WITH DUE CARE AND

DILIGENCE IN ORDER TO PREVENT ARBITRARY DAMAGE OR INTERRUPTION

OF SERVICE OR CONCEALED UTILITIES INTENDED TO REMAIN IN SERVICE.

DISCOVERY OF UTILITIES OR CONDITIONS LOCATED DIFFERING FROM THOSE

INDICATED OR THAT ARE NOT IDENTIFIED, SHALL BE REPORTED TO THE COR.

13. VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK. NOTIFY COR

AND ARCHITECT OF ANY CONFLICTS PRIOR TO PROCEEDING WITH

DEMOLITION.

14. ALL ITEMS BEING SALVAGED OR REMOVED SHALL REMAIN THE PROPERTY OF

THE OWNER UNTIL CONFIRMATION HAS BEEN MADE AS TO WHETHER THE

OWNER WILL RETAIN SUCH ITEMS. ALL ITEMS NOT BEING RETAINED BY THE

OWNER OR DESIGNATED ON THE DRAWINGS, ARE TO BE RELOCATED OR

REINSTALLED FROM THE SITE BY CONTRACTOR IN APPROVED MANNER.

15. CONTRACTOR SHALL NOTIFY COR OF ANY AREA REQUIRING DEMOLITION

OTHER THAN SHOWN IN THESE DRAWINGS DUE TO UNFORESEEN

CONDITIONS, TO ACCOMMODATE INSTALLATION OF ALL OTHER TRADES

(INCLUDING ROOF PENETRATIONS). AFTER SUCH DEMOLITION AND

INSTALLATION, PATCH OR REPLACE MATERIALS AND FINISHES TO MATCH

EXISTING.

16. COORDINATE WITH COR FOR CONSTRUCTION ACCESS ROUTE AND

LOCATIONS OF DUMPSTER AREA. COORDINATE WITH COR FOR SCHEDULE

OF USE OF ACCESS ROUTE FOR WASTE REMOVAL AND CONTRACTOR USE

OF FREIGHT ELEVATOR (AS REQUIRED).

WALL SECTION

SYMBOL

INTERIOR ELEVATION

SYMBOL

COLUMN GRID

ELEVATION SYMBOL

REVISION NOTE

ENLARGED DETAIL CALLOUT

ROOM DESIGNATION

SYMBOL

BREAK LINE

ROOF SLOPE

DIRECTION SYMBOL

TYPICAL GRAPHIC SCALE

DETAIL #

PAGE #

DETAIL #

PAGE #

VIEW NORTH ARROW

A8.1

EXTERIOR ELEVATION

SYMBOL

DETAIL #

PAGE #

A8.1

A8.1

A8.1

BUILDING SECTION

SYMBOL

DETAIL #

PAGE #

A8.1

A8.1

DETAIL SECTION

SYMBOL

DETAIL #

PAGE #

A8.1

WALL GRID

(REPRESENTS

FACE OF EXISTING

WALL)

XX.X

XX.X

ELEVATION

0'-0"

ROOM

NAME

101A

0 4 8 16

NORTH

DEMOLITION KEYNOTE

WINDOW TYPE

ROOF PITCH SYMBOL

DOOR NUMBER

TYPICAL KEYNOTE CEILING/ SOFFIT

HEIGHT

MATL

1'-0"

1 #

22-119 CINCINNATI VA MEDICAL CENTER - UPGRADE ELEVATORS

BUILDING

PASSENGER ELEVATOR INFORMATION CAPACITY ELEVATOR

ELEVATOR WIDTH DEPTH (LBS)

SPEED

(FPM)

DOOR

TYPE MANUF./YEAR

TWO SPEED

TWO SPEED

TWO SPEED

TWO SPEED

TWO SPEED

TWO SPEED

TWO SPEED

OTIS (*1953)

OTIS (*1953)

OTIS (*1953)

OTIS (*1953)

ARMOR (*1983)

ARMOR (*1983)

DOVER (2006)

ELEVATOR

CAB DESIGN

ELEVATOR TYPE

HYDRAULIC TRACTION

B,1,2,3,4,5,6,7,8,9

NO. OF FLOORS

SERVED

OPENINGS

FRONT "ONLY" FRONT & BACK

ELEVATOR

RE-NUMBER

REPLACE

FLOOR

REPLACE

BASE

REPLACE

WALL PNLS

REPLACE

CEILING

PROVIDE (2)

HANDRAILS

PROVIDE (1)

CRASHRAIL REMARKS

P-1

P-2

P-3

P-4

P-9

P-15

P-16

VIF

VIF

VIF

VIF

VIF

VIF

VIF

VIF

VIF

VIF

VIF

VIF

VIF

VIF

4,000

4,000

4,0004,000

4,000

4,500

5,000

5,000

TYPE A

TYPE A

TYPE A

TYPE A

TYPE A

TYPE A

TYPE A

X

X

X

X

X

X

X

B,1,2,3,4,5,6,7,8,9

B,1,2,3,4,5,6,7,8,9

B,1,2,3,4,5,6,7,8,9

B,1,2,3,4,5,6,7,8,9

B,1,2,3,4,5,6,7,8,9

B,1,1R,2,2R,3,3R

X

X

X

X

X

X

X

NO

NO

NO

NO

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

1, 2, 3, 4, 7

1, 2, 3, 4, 7

1, 2, 3, 4, 7

1, 2, 3, 4, 7

5, 6, 9,10

1, 3, 9

1, 3, 9

TWO SPEED ARMOR (**2008)P-715 VIF VIF 4,000 150 TYPE A X B,1,2,3,4 X 4, 7, 8YES YES YES YES YESYES

BUILDING 15 (RESEARCH)

REMARKS:

1. CAR STATION EMERGENCY PHONE SIGNAGE NEEDS TO BE REPLACED AS SOON AS POSSIBLE.

2. REFINISH STAINLESS STEEL LOBBY SIDE ELEV. DOOR PANELS AND REMOVE & REFURBISH BRONZE DECORATIVE MEDALLION SYMBOLS

3. INCORPORATE EXISTING AUXILIARY CAR STATION INTO NEW WALL PANEL DESIGN AT THE SAME LOCATION.

4. REFINISH STAINLESS STEEL SURFACES ON THE FRONT OF THE CAB.

5. REPLACE THE FOLLOWING DEVICES IN PLACE: MAIN & AUXILIARY CAR OPERATING PANELS; HALL CONTROL STATIONS; CAR POSITION INDICATORS; HALL DIRECTIONAL LANTERNS; AND HALL POSITION INDICATOR.

6. REPLACE OMEGA RAIL CAR SLIDE GUIDE SHOE INSERTS

7. INSTALL HOISTWAY DOOR ESCUTCHEON TUBES WITHIN THE NEXT YEAR. EMERGENCY PHONE SIGNAGE NEEDS TO BE REPLACED AS SOON AS POSSIBLE.

8.

* ELEVATORS WERE MODERNIZED IN 2014

** ELEVATORS WERE MODERNIZED IN 2008

*** PROVIDE AN ADDITIONAL #4 SATIN STAINLESS -STEEL HANDRAIL @ 42" A.F.F. TO MATCH EXISTING HANDRAIL TO REMAIN IN PLACE.

**** NEW CAB FLOORING SHALL BE LUXURY VINYL TILE. THE NEW FLOORING SHALL BE CAULKED WITH SILICONE AROUND THE INTERIOR PERIMETER TO LIMIT WATER INFILTRATION TO THE CAB PLATFORM.

22-119 CINCINNATI VA MEDICAL CENTER - UPGRADE ELEVATORS

BUILDING

SERVICE ELEVATOR INFORMATION CAPACITY ELEVATOR

ELEVATOR WIDTH DEPTH (LBS)

SPEED

(FPM)

DOOR

TYPE MANUF./YEAR

TWO SPEED

TWO SPEED

OTIS (*1953)

OTIS (*1953)

ELEVATOR

CAB DESIGN

ELEVATOR TYPE

HYDRAULIC TRACTION

B,1,2,3,4,5,6,7,8,9

NO. OF FLOORS

SERVED

OPENINGS

FRONT "ONLY" FRONT & BACK

ELEVATOR

RE-NUMBER

REPLACE

FLOOR

REPLACE

BASE

REPLACE

WALL PNLS

REPLACE

CEILING

PROVIDE (2)

HANDRAILS

PROVIDE (1)

CRASHRAIL REMARKS

S-5

S-6

VIF

VIF

VIF

VIF

5,000

5,000

X

X B,1,2,3,4,5,6,7,8,9

X

X

YES

YES

YES

YES

NO

NO

YES

YES

YES

YES

YES

YES

1, 2, 3, 4, 5, 6

1, 2, 3, 4, 5, 6

1. CAR STATION EMERGENCY PHONE SIGNAGE NEEDS TO BE REPLACED AS SOON AS POSSIBLE.

2. REFINISH EXISTING CAB INTERIOR. REFINISH ALL EXISTING STAINLESS STEEL SURFACES

3. INSTALL NEW #4 SATIN STAINLESS-STEEL CRASH RAIL, AND 2 STAINLESS STEEL HANDRAILS

4. INSTALL NEW RUBBER BASE

5. RE-DRILL HOLES AND INSTALL NEW STAINLESS PAD BUTTONS AND PROVIDE NEW WALL PAD PROTECTION

6. REMOVE EXISTING DROP CEILING AND LIGHTING. PROVIDE NEW #4 SATIN STAINLESS STEEL LED COVE LIGHTS, ON BOTH SIDES OF THE CAB, AND PROVIDE NEW WHITE PLASTIC LAMINATE PANELS ON THE CAB CEILING. SEE DETAIL

* ELEVATORS WERE MODERNIZED IN 2014

REPLACE EXIST. EMERGENCY PHONE WITH A NEW SURFACE/FLUSH MOUNTED PHONE INSTALLED OVER THE EXISTING CABINET OPENING.

NO

NO

NO

9. REFINISH STAINLESS STEEL ON FRONT AND REAR OF THE CAB.

NO

10. PROVIDE CARD READER "PACS" SYSTEM. CARD READER DEVICE SHALL BE MOUNTED ABOVE THE NEW ELEVATOR CONTROL PANEL. COORDINATE FLOOR BY FLOOR ACCESS WITH A JOHNSON CONTROLS PAC SYSTEM. SEE SPECIFICATIONS AND THE TECHNOLOGY DRAWINGS FOR MORE INFORMATION.

FINISH SCHEDULE

NOTE: ELEVATOR CONTROL PER ELEVATOR SPECIFICATION DIVISION 14

HIW-1

PROVIDE FINISHES LISTED AS BASIS OF DESIGN OR APPROVED EQUAL

HIW-2

WALLS-

LVT-1

HANDRAILS-

CEILING-

INPRO/ASCEND ELEVATOR CABS/HIGH IMPACT WALLCOVERING/INPRO/PALLADIUM/HAZELWOOD #0536/STAINLESS STEEL EDGE WRAPPED

INPRO/ASCEND ELEVATOR CABS/HIGH IMPACT WALLCOVERING/INPRO/PALLADIUM/BRUSHED SILVER 5E025/STAINLESS STEEL EDGE WRAPPED

EXISTING STAINLESS STEEL ENCLOSURE WALLS

TARKET/ID LATITUDE, STRIA MARBLE, NIMBUS 5102

INPRO ASCEND/ Flat, 3/8”(9.5mm) x 4”(102mm) WITH STRAIGHT ENDS, #4 STAINLESS STEEL

INPRO/ASCEND ELEVATOR/LED DOWNLIGHTS WITH #8 STAINLESS PANELS, GRAIN FROM FRONT OF CAB TO REAR

CRASHRAILS- INPRO ASCEND/ Flat, 3/8”(9.5mm) x 8”(203.2mm) WITH STRAIGHT ENDS, #4 STAINLESS STEEL, BASE- JOHNSONITE #40 BLACK/4" H

CEILING- WHITE LAMINATE CEILING PANELS

BASE- INPRO ASCEND/STAINLESS STEEL #4

1. PROPOSED PHASING FOR THIS PROJECT SHALL BE 1 ELEVATOR CAB AT A

TIME. GC SHALL PERFORM ALL CAB REWORK AT THE BASEMENT LEVEL

INSIDE THE SHAFT FOR ALL CABS IN THE PROJECT.

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

Headquarters:

Michael Blades & Associates, Ltd.

5409 Rapidan Ct, Lothian, MD 20711 www.elevatormba.com 410-798-8504© 2020 Michael Blades & Associates, Ltd.

/2

/2

:4

:4

P

M C

U s e rs

\b n e e d h a m

\D o c u m e n ts \A

-1

-V

A C in c in n a ti -E le v a to r

U p g r E le v -O

H b n e e d h a m

H L

.r v t

A-001

ARCHITECTURAL SYMBOLS,

ABBREVIATIONS AND NOTES

1 8BN

UPGRADE ELEVATORS

CINCINNATI VA MEDICAL CENTER

3200 VINE STREET

CINCINNATI, OH, 45220 MARCH 17, 2023

BID DOCUMENTS

539-23-20322-119

JAB

ABBREVIATIONS

GENERAL NOTES

DEMOLITION NOTES

GENERAL SYMBOL LEGEND

ARCHITECTURAL SYMBOL LEGEND

Scale: No Scale

PASSENGER ELEVATOR

(TYPE A) CAB INTERIOR

DESIGN

1 #8 STAINLESS STEEL PANEL CEILING, WITH

LED DOWNLIGHTS.

2 HIW-1 HIGH IMPACT WALLCOVERING WITH

STAINLESS STEEL TRIM - UPPER PANEL.

3 #4 STAINLESS STEEL - UPPER PANEL.

4 PANEL TRIM - SATIN STAINLESS STEEL.

5 3" STAINLESS STEEL FLAT HANDRAIL AT 42"

HIGH TO THE CENTER OF THE RAIL.

6 3" STAINLESS STEEL FLAT HANDRAIL AT 30"

HIGH TO THE CENTER OF THE RAIL.

7 HIW-2 HIGH IMPACT WALLCOVERING WITH

STAINLESS STELL TRIM - LOWER PANEL

8 8" STAINLESS STEEL CRASHRAIL AT 12" HIGH

TO THE CENTER OF THE RAIL.

9 4" STAINLESS STEEL HIGH BASE

10 NEW LVT FLOORING

ELEVATOR SCHEDULE

ROOM FINISH SCHEDULE

BLDG # ELEVATOR # FLOOR BASE

WALLS CEILING

REMARKSEAST NORTH SOUTH WEST FINISH

1 PASSENGER 1-4 LVT-1 RUBBER

BASE

HIW-1/HIW-2 HIW-1/HIW-2 HIW-1/HIW-2 HIW-1/HIW-2 SS-1

1 SERVICE 5-6 LVT-1 RUBBER

BASE

SS-1 SS-1 SS-1 SS-1 LAMINATE REFINISH EXISTING STAINLESS

STEEL CABS

1 PASSENGER 9 LVT-1 RUBBER

BASE

HIW-1/HIW-2 HIW-1/HIW-2 HIW-1/HIW-2 HIW-1/HIW-2 SS-1

1 PASSENGER 15-16 LVT-1 RUBBER

BASE

HIW-1/HIW-2 HIW-1/HIW-2 HIW-1/HIW-2 HIW-1/HIW-2 SS-1

15 PASSENGER 7 LVT-1 RUBBER

BASE

HIW-1/HIW-2 HIW-1/HIW-2 HIW-1/HIW-2 HIW-1/HIW-2 SS-1

1, 15

PHASING NOTES

DN

ELEVATORS P-1, P-2, P-3, P-4

ELEVATORS P-15, P-16

ELEVATOR P-9

ELEVATORS S-5, S-6

A-101

A-102

A-104

A-103

ELEVATORS INCLUDED IN

SCOPE OF WORK

LEGEND

ELEVATOR P-9

LOCATION OF

PANEL CBD.

ELEC.

A032E

CANTEEN

STORAGE

A030

EMS OFFICE

A031A

CHIEF EMS

OFFICE

A031B

EMS SUPER

OFFICE

A031C

HOTEL SPACE

A031D

OFFICE

A031F

OFFICE

A040

STORAGE

A041 STOR.

A042

ELEV. MECH.

ROOM

A043

STAIR 5

S*B*5

FAN ROOM

A028

ELEC.

A032

OFFICE

A047E

OFFICE

A047F

CODING

DEPARTMENT

A045

TLT.

A044

BREAK ROOM

A032A

STORAGE

A032

CHIEF EMS

OFFICE

A031

SOIL

A032G

CLOTHING RM

A033B

CONTROLLED

SUBSTANCE

PROGRAM

MANAGER

A031E

HATCHED AREA INDICATES ROUTE FOR NEW POWER CABLEING FOR

NEW PACS/CARD READER FOR ELEVATOR P-9. THIS SHALL REQUIRE

CABLE WORK TO BE COMPLETED AT NIGHT, OR ON THE WEEKEND,

TO MINIMIZE DISRUPTION TO HOSPITAL PATIENTS, STAFF, AND

VISTORS. SOME CEILING TILES, AND POSSIBLE MINOR CEILING GRID

(REMOVE AND REINSTALL,) WILL BE AFFECTED IN THE PATHWAY

INDICATED WHICH WILL REQUIRE TEMPORARY LEVEL II (PLASTIC

BARRIERS IN CORRIDORS) ICRA MEASURES.

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

Headquarters:

Michael Blades & Associates, Ltd.

5409 Rapidan Ct, Lothian, MD 20711 www.elevatormba.com 410-798-8504© 2020 Michael Blades & Associates, Ltd.

/2

/2

:4

:5

P

M C

U s e rs

\b n e e d h a m

\D o c u m e n ts \A

-1

-V

A C in c in n a ti -E le v a to r

U p g r E le v -O

H b n e e d h a m

H L

.r v t

A-100

OVERALL BUILDING 1 GROUND FLOOR

PLAN

2 8BN

UPGRADE ELEVATORS

CINCINNATI VA MEDICAL CENTER

3200 VINE STREET

CINCINNATI, OH, 45220 MARCH 17, 2023

BID DOCUMENTS

539-23-20322-119

JAB

Scale: 3/64" = 1'-0"

OVERALL BUILDING 1 GROUND FLOOR PLAN

N O

R T

H0 4 8 16

Scale: 3/64" = 1'-0"

PARTIAL BUILDING 1 BASEMENT FLOOR PLAN

N O

R T

H0 4 8 16

A-1015

A-101 2

SIM

HORIZONTAL

CONTROL PANEL

VERTICAL CONTROL

PANEL

7'-1"

COORDINATE

EMERGENCY EXIT

HATCH WITH CAB

CEILING

PROVIDE (8) LED

ILLUMINATED

CAR LIGHT

FIXTURES ABOVE

THE CEILING.

MAINTAIN A

MINIMUM LIGHT

LEVEL OF 50-

FOOT CANDLES

AT (36") ABOVE

THE FINISHED

FLOOR.

PROVIDE S.S.

HANGING CEILING

FRAME. CONSTRUCT

FRAME OF .125" X

1.50" X 1.50" "T" AND

"L" SECTIONS.

TOP OF CAB

PROVIDE NEW MAIN

CAR OPERATING PANEL

IN THE CAR ENCLOSURE

ON THE FRONT RETURN

PANEL. CONTRACTOR

TO VERIFY LOCATION

PER CAB INTERIOR. SEE

ELEVATOR

SPECIFICATIONS

REFINISH STAINLESS

STEEL SURFACES ON

THE FRONT OF THE

CAB AND DOOR.

FLOOR INDICATOR TO REMAIN,

CLEAN AND REFURBISH

1" EQ 1" EQ 1"

STAINLESS STEEL CEILING

TOP OF CAB

PROVIDE CAR ENCLOSURE WITH

NEW HANDRAILS @ CENTERLINES

OF 42" AND 30" ABOVE THE CAR

FLOOR. MATCH EXIST. SPACING

OF HANDRAIL FROM CAB WALL.

CONCEAL ALL HANDRAIL

FASTENINGS HANDRAILS SHALL

BE REMOVABLE FROM THE INSIDE

OF THE CAR ENCLOSURE.

LOCATE HANDRAILS 1-1/2" FROM

CAB WALL. PROVIDE FLAT STOCK

HANDRAILS WITH THE ENDS AT

THE ENTRANCE TURNED BACK TO

THE WALL.

PROVIDE AN AUXILIARY CAR

OPERATING PANEL IN

THE SIDE WALL OF THE

ELEVATOR IN ITS CURRENT

LOCATION IMMEDIATELY

ADJACENT TO THE FRONT

ENTRANCE STRIKE JAMB

COLUMN.

PROVIDE CAR ENCLOSURE WITH

NEW HIGH IMPACT

WALLCOVERING, HIW-1 PANELS

AND STAINLESS STEEL TRIM

1" EQ 1" EQ 1" EQ 1" EQ

PROVIDE NEW 8" TALL CRASH RAIL

@8" ABOVE CAR FLOOR.

CONCEAL ALL CRASH RAIL

FASTENINGS. CRASH RAIL SHALL

BE REMOVABLE FROM THE

INSIDE OF THE CAR ENCLOSURE.

PROVIDE FLAT STOCK CRASH

RAILS WITH THE ENDS AT THE

ENTRANCE TURNED BACK TO THE

WALL.

NEW HIGH IMPACT

WALLCOVERING, HIW-2 PANELS

AND STAINLESS STEEL TRIM.

PROVIDE NEW STAINLESS STEEL

HOOKS AND ELEVATOR PADS TO

PASSENGER ELEVATOR CAB ON 3

SIDES

REMOVE AND REINSTALL

CAB SPEAKERS.

REPLACE SIGNAGE

NEW STAINLESS STEEL BASE

HALL LANTERN TO REMAIN

HOISTWAY DOORS TO BE

REFINISHED - SEE ELEVATOR

SPECIFICATIONS.

REFINISH EXISTING

STAINLESS STEEL

ENTRANCE FRAME,

BOTH JAMBS.

REFINISH EXISTING

STAINLESS STEEL ENTRANCE

FRAME, TOP HEADER, AS

REQUIRED.

CLEAN & REFURBISH BRONZE

DECORATIVE SYMBOLS ON

GROUND FLOOR ONLY. ALL

P-1 THRU P-4 HOISTWAY

DOORS

INSTALL HOISTING DOOR

ESCUTCHEON TUBES

STAINLESS STEEL

CEILING

TOP OF CAB

PROVIDE CAR ENCLOSURE WITH NEW

HANDRAILS @ CENTERLINES OF 42"

AND 30" ABOVE THE CAR FLOOR.

MATCH EXIST. SPACING OF HANDRAIL

FROM CAB WALL. CONCEAL ALL

HANDRAIL FASTENINGS HANDRAILS

SHALL BE REMOVABLE FROM THE

INSIDE OF THE CAR ENCLOSURE.

LOCATE HANDRAILS 1-1/2" FROM CAB

WALL. PROVIDE FLAT STOCK

HANDRAILS WITH THE ENDS AT THE

ENTRANCE TURNED BACK TO THE

WALL.

PROVIDE CAR ENCLOSURE WITH

NEW HIGH IMPACT WALLCOVERING,

HIW-1 PANELS AND STAINLESS STEEL

TRIM

1" EQ 1" EQ 1"

PROVIDE NEW 8" TALL CRASH RAIL

@8" ABOVE CAR FLOOR.

CONCEAL ALL CRASH RAIL

FASTENINGS. CRASH RAIL SHALL

BE REMOVABLE FROM THE

INSIDE OF THE CAR ENCLOSURE.

PROVIDE FLAT STOCK CRASH RAILS

WITH THE ENDS AT THE ENTRANCE

TURNED BACK TO THE WALL.

NEW HIGH IMPACT WALLCOVERING,

HIW-2 PANELS AND STAINLESS STEEL

TRIM

PROVIDE NEW STAINLESS STEEL

HOOKS AND ELEVATOR PADS TO

PASSENGER ELEVATOR CAB ON 3

SIDES

REPLACE

SIGNAGE

REINSTALL

FLOOR

INDICATOR

REPLACE

SIGNAGE

NEW STAINLESS STEEL BASE

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

Headquarters:

Michael Blades & Associates, Ltd.

5409 Rapidan Ct, Lothian, MD 20711 www.elevatormba.com 410-798-8504© 2020 Michael Blades & Associates, Ltd.

/2

/2

:4

:4

P

M C

U s e rs

\b n e e d h a m

\D o c u m e n ts \A

-1

-V

A C in c in n a ti -E le v a to r

U p g r E le v -O

H b n e e d h a m

H L

.r v t

A-101

BUILDING 1 TYPICAL PASSENGER (P-1

THRU P-4) ELEVATOR CAB PLANS AND

INTERIOR ELEVATIONS

3 8BN

UPGRADE ELEVATORS

CINCINNATI VA MEDICAL CENTER

3200 VINE STREET

CINCINNATI, OH, 45220 MARCH 17, 2023

BID DOCUMENTS

539-23-20322-119

JAB

Scale: 1/2" = 1'-0"

BUILDING 1

ELEVATOR CAB FLOOR PLAN

(P-1 THRU P-4)

Scale: 1/2" = 1'-0"

BUILDING 1

ELEVATOR CAB REFLECTED CEILING PLAN

(P-1 THRU P-4)

N O

R T

H0 1 2 4

N O

R T

H0 1 2 4

Scale: 3/4" = 1'-0"

BUILDING 1

CAB FRONT INTERIOR ELEVATION

(P-1 THRU P-4)

Scale: 3/4" = 1'-0"

BUILDING 1

CAB SIDE INTERIOR ELEVATION (2 SIDES)

(P-1 THRU P-4)

Scale: 3/4" = 1'-0"

BUILDING 1

TYPICAL EXTERIOR DOOR ELEVATION

(P-1 THRU P-4)

Scale: 3/4" = 1'-0"

BUILDING 1

CAB REAR INTERIOR ELEVATION

(P-1 THRU P-4)

0 1 2

BLDG 1 EXIST. ELEVATOR CAB PHOTO P-10 1 2 0 1 2 0 1 2

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

BLDG

BLDG 1

1 REMOVE EXISTING FLOORING, WALL PANELS,

BASE, HANDRAILS, OPERATING PANEL AND

SIGNAGE.

A. ALL ELECTRICAL WORK REQUIRED BY THIS

MODIFICATION IS THE RESPONSIBILITY OF

THE ELEVATOR CONTRACTOR. IF ANY WORK

REQUIRES A LICENSED ELECTRICIAN, THIS

SHALL BE INCLUDED IN THE RESPONSIBILITY

OF THE ELEVATOR COMPANY TO RETAIN AND

PROVIDE SUCH AN INDIVIDUAL IF

NECESSARY. NO WORK IS PROJECTED TO BE

REQUIRED UPSTREAM OF THE MAIN LINE

ELEVATOR POWER OR UPSTREAM OF THE

ELEVATOR CAB LIGHTS DISCONNECT.

B. PHOTO INDICATES ONE ELEVATOR CAB FOR

DEMOLITION AND NEW WORK, BUT OVERALL

PROJECT INCLUDES ALL CARS IN THIS BANK

OF ELEVATORS.

C. SEE ELEVATOR SCHEDULE ON SHEET A-001

FOR MORE INFORMATION.

A-1022 4

SIM

7'-3"

VERTICAL CONTROL PANEL

HORIZONTAL CONTROL PANEL

NEW S.S. LIGHT COVE

NEW LED COVE

LIGHTING

NEW WHITE LAMINATE

CEILING PANELS

COORDINATE EMERGENCY EXIT

HATCH WITH CAB CEILING

TOP OF CAB

CLEAN AND REFINISH

STAINLESS STEEL DOOR

AND WALLS AND

CONTROLS.

FLOOR INDICATOR TO

REMAIN, CLEAN AND

REFURBISH

EXISTING CAR OPERATING

PANEL TO REMAIN, CLEAN

AND REFINISH.

MATCH EXISTING HEIGHT OF

CEILING WITH NEW

REPLACE CAR STATION EMERGENCY

PHONE SIGNAGE

1" EQ 1" EQ 1"

TOP OF CAB

PROVIDE AN AUXILIARY

CAR OPERATING PANEL

IN THE SIDE WALL OF

THE ELEVATOR IN ITS

CURRENT LOCATION

IMMEDIATELY ADJACENT

TO THE FRONT

ENTRANCE STRIKE JAMB

COLUMN.

PROVIDE NEW 8" TALL

CRASH RAIL @8" ABOVE

CAR FLOOR.

CONCEAL ALL CRASH RAIL

FASTENINGS. CRASH RAIL

SHALL BE REMOVABLE

FROM THE INSIDE OF THE

CAR ENCLOSURE. PROVIDE

FLAT STOCK CRASH RAILS

WITH THE ENDS AT THE

ENTRANCE TURNED BACK

TO THE WALL.

PROVIDE NEW STAINLESS

STEEL HOOKS AND

ELEVATOR PADS TO

SERVICE ELEVATOR CAB ON

3 SIDES

NEW STAINLESS

STEEL LIGHT COVE

NEW LAMINATE CEILING

PANELS

NEW RUBBER BASE, RB-1

REMOVE AND

REINSTALL SPEAKER

REMOVE AND

REINSTALL SIGNAGE

CLEAN AND REFINISH

S.S. WALLS

CLEAN AND REFINISH

STAINLESS STEEL

WALLS

1" EQ 1" EQ 1"

TOP OF CAB

1" EQ 1" EQ 1"

PROVIDE NEW 8" TALL CRASH RAIL

@8" ABOVE CAR FLOOR.

CONCEAL ALL CRASH RAIL

FASTENINGS. CRASH RAIL SHALL

BE REMOVABLE FROM THE

INSIDE OF THE CAR ENCLOSURE.

PROVIDE FLAT STOCK CRASH

RAILS WITH THE ENDS AT THE

ENTRANCE TURNED BACK TO THE

WALL.

NEW LAMINATE CEILING

PANELS

NEW STAINLESS STEEL

LIGHT COVE

NEW LED COVE LIGHT

CLEAN AND REFINISH

STAINLESS STEEL

WALLS

NEW RUBBER BASE,

RB-1

FLOOR INDICATOR TO REMAIN,

CLEAN AND REFURBISH

PROVIDE NEW STAINLESS STEEL

HOOKS AND ELEVATOR PADS TO

SERVICE ELEVATOR CAB ON 3

SIDES

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

Headquarters:

Michael Blades & Associates, Ltd.

5409 Rapidan Ct, Lothian, MD 20711 www.elevatormba.com 410-798-8504© 2020 Michael Blades & Associates, Ltd.

/2

/2

:4

:5

P

M C

U s e rs

\b n e e d h a m

\D o c u m e n ts \A

-1

-V

A C in c in n a ti -E le v a to r

U p g r E le v -O

H b n e e d h a m

H L

.r v t

A-102

BUILDING 1 TYPICAL SERVICE (S-5 /

S-6) ELEVATOR CAB PLANS AND

INTERIOR ELEVATIONS

4 8BN

UPGRADE ELEVATORS

CINCINNATI VA MEDICAL CENTER

3200 VINE STREET

CINCINNATI, OH, 45220 MARCH 17, 2023

BID DOCUMENTS

539-23-20322-119

JAB

Scale: 1/2" = 1'-0"

BUILDING 1

ELEVATOR CAB FLOOR PLAN

(S-5 & S-6)

Scale: 1/2" = 1'-0"

BUILDING 1

ELEVATOR CAB REFLECTED CEILING PLAN

(S-5 & S-6)

N O

R T

H0 1 2 4

N O

R T

H0 1 2 4

Scale: 3/4" = 1'-0"

BUILDING 1

CAB FRONT INTERIOR ELEVATION

(S-5 & S-6)

Scale: 3/4" = 1'-0"

BUILDING 1

CAB SIDE INTERIOR ELEVATION (2 SIDES)

(S-5 & S-6)

Scale: 3/4" = 1'-0"

BUILDING 1

CAB REAR INTERIOR ELEVATION

(S-5 & S-6) BLDG 1 EXIST. ELEVATOR CAB PHOTO S-50 1 2

0 1 2

0 1 2

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

BLDG

BLDG 1

1 REMOVE FLOORING AND BASE AND SIGNAGE

A. ALL ELECTRICAL WORK REQUIRED BY

THIS MODIFICATION IS THE

RESPONSIBILITY OF THE ELEVATOR

CONTRACTOR. IF ANY WORK REQUIRES

A LICENSED ELECTRICIAN, THIS SHALL

BE INCLUDED IN THE RESPONSIBILITY OF

THE ELEVATOR COMPANY TO RETAIN

AND PROVIDE SUCH AN INDIVIDUAL IF

NECESSARY. NO WORK IS PROJECTED

TO BE REQUIRED UPSTREAM OF THE

MAIN LINE ELEVATOR POWER OR

UPSTREAM OF THE ELEVATOR CAB

LIGHTS DISCONNECT.

B. PHOTO INDICATES ONE ELEVATOR CAB

FOR DEMOLITION AND NEW WORK, BUT

OVERALL PROJECT INCLUDES ALL CARS

IN THIS BANK OF ELEVATORS.

C. SEE ELEVATOR SCHEDULE ON SHEET

A-001 FOR MORE INFORMATION.

A-103

" A-1035A-103 5

9'-0"

VERTICAL

CONTROL PANEL

VERTICAL

CONTROL PANEL

COORDINATE

EMERGENCY EXIT

HATCH WITH CAB

CEILING

PROVIDE (6) LED

ILLUMINATED CAR

LIGHT FIXTURES

ABOVE THE CEILING.

MAINTAIN A MINIMUM

LIGHT LEVEL OF 50-

FOOT CANDLES AT

(36") ABOVE THE

FINISHED FLOOR.

PROVIDE S.S.

HANGING CEILING

FRAME. CONSTRUCT

FRAME OF .125" X

1.50" X 1.50" "T" AND

"L" SECTIONS.

TOP OF CAB

PROVIDE NEW MAIN CAR

OPERATING PANEL IN

THE CAR ENCLOSURE ON

THE FRONT RETURN

PANEL. CONTRACTOR TO

VERIFY LOCATION PER

CAB INTERIOR. SEE

ELEVATOR

SPECIFICATIONS

CLEAN AND REINISH

STAINLESS STEEL DOOR,

WALL SURFACE AND

DOOR CONTROLS

REPLACE KEYPAD WITH

NEW CARD READER (PACS)

DEVICE

SIGNAGE TO REMAIN

HOLDER TO REMAIN

FLOOR INDICATOR TO

BE REPLACED

NEW STAINLESS STEEL

CEILING; MATCH EXISTING

HEIGHT OF CEILING

TOP OF CAB

PROVIDE CAR ENCLOSURE

WITH NEW HANDRAILS @

CENTERLINEs OF 42" and 32"

ABOVE THE CAR FLOOR.

MATCH EXIST. SPACING OF

HANDRAIL FROM CAB WALL.

CONCEAL ALL HANDRAIL

FASTENINGS HANDRAILS SHALL

BE REMOVABLE FROM THE

INSIDE OF THE CAR

ENCLOSURE. LOCATE

HANDRAILS 1-1/2" FROM CAB

WALL. PROVIDE FLAT STOCK

HANDRAILS WITH THE ENDS AT

THE ENTRANCE TURNED BACK

TO THE WALL.

PROVIDE CAR ENCLOSURE

WITH NEW HIGH IMPACT

WALLCOVERING, HIW-1

PANELS AND STAINLESS

STEEL TRIM

1" EQ 1" EQ 1" EQ

PROVIDE NEW 8" TALL CRASH RAIL

@8" ABOVE CAR FLOOR.

CONCEAL ALL CRASH RAIL

FASTENINGS. CRASH RAIL SHALL

BE REMOVABLE FROM THE

INSIDE OF THE CAR ENCLOSURE.

PROVIDE FLAT STOCK CRASH

RAILS WITH THE ENDS AT THE

ENTRANCE TURNED BACK TO THE

WALL.

NEW HIGH IMPACT

WALLCOVERING, HIW-2

PANELS AND STAINLESS

STEEL TRIM

PROVIDE NEW STAINLESS STEEL

HOOKS AND ELEVATOR PADS TO

PASSENGER ELEVATOR CAB ON 2

SIDES

1" EQ 1" EQ 1" EQ 1" EQ 1"

NEW STAINLESS STEEL BASE

REPLACE HALL DIRECTIONAL AND

POSITION INDICATORS.

REPLACE HALL

CONTROLS

STATION

FLOOR INDICATOR TO BE

REPLACED

SIGNAGE TO BE REMOVED

AND REINSTALLED

PROVIDE NEW MAIN CAR

OPERATING PANEL IN THE

CAR ENCLOSURE ON THE

FRONT RETURN PANEL.

CONTRACTOR TO VERIFY

LOCATION PER CAB

INTERIOR. SEE ELEVATOR

SPECIFICATIONS

CLEAN AND REINISH

STAINLESS STEEL DOOR,

WALL SURFACE AND DOOR

CONTROLS

TOP OF CAB

Engineers Architects

# KEY NOTES:

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

Headquarters:

Michael Blades & Associates, Ltd.

5409 Rapidan Ct, Lothian, MD 20711 www.elevatormba.com 410-798-8504© 2020 Michael Blades & Associates, Ltd.

/2

/2

:4

:0

P

M C

U s e rs

\b n e e d h a m

\D o c u m e n ts \A

-1

-V

A C in c in n a ti -E le v a to r

U p g r E le v -O

H b n e e d h a m

H L

.r v t

A-103

BUILDING 1 TYPICAL PASSENGER (P-9)

ELEVATOR CAB PLANS AND INTERIOR

ELEVATIONS

5 8BN

UPGRADE ELEVATORS

CINCINNATI VA MEDICAL CENTER

3200 VINE STREET

CINCINNATI, OH, 45220 MARCH 17, 2023

BID DOCUMENTS

539-23-20322-119

JAB

Scale: 1/2" = 1'-0"

BUILDING 1

ELEVATOR CAB REFLECTED CEILING PLAN

(P-9)

Scale: 1/2" = 1'-0"

BUILDING 1

ELEVATOR CAB REFLECTED CEILING PLAN

(P-9)

Scale: 3/4" = 1'-0"

BUILDING 1

CAB FRONT INTERIOR ELEVATION

(P-9)

Scale: 3/4" = 1'-0"

BUILDING 1

CAB INTERIOR SIDE ELEVATION (2 SIDES)

(P-9)

Scale: 3/4" = 1'-0"

BUILDING 1

TYPICAL EXTERIOR DOOR ELEVATION

(P-9)

Scale: 3/4" = 1'-0"

BUILDING 1

CAB REAR INTERIOR ELEVATION

(P-9) BLDG 1 EXIST. ELEVATOR CAB PHOTO P-9

N O

R T

H0 4 8 16

N O

R T

H0 4 8 160 1 2

0 1 20 1 2 0 1 2

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

BLDG

BLDG 1

1 REMOVE EXISTING FLOORING, HANDRAIL,

WALL PANELS, CEILING AND LIGHTS

1 REPLACE OMEGA RAIL CAR SLIDE SHOE

INSERT

2 PROVIDE CARD READER DEVICE AND

SOFTWARE FOR RESTRICTED FLOOR

ACCESS. SEE ELECTRICAL AND

TECHNOLOGY DRAWINGS FOR MORE

INFORMATION

A. ALL ELECTRICAL WORK REQUIRED BY THIS

MODIFICATION IS THE RESPONSIBILITY OF

THE ELEVATOR CONTRACTOR. IF ANY

WORK REQUIRES A LICENSED

ELECTRICIAN, THIS SHALL BE INCLUDED IN

THE RESPONSIBILITY OF THE ELEVATOR

COMPANY TO RETAIN AND PROVIDE SUCH

AN INDIVIDUAL IF NECESSARY. NO WORK IS

PROJECTED TO BE REQUIRED UPSTREAM

OF THE MAIN LINE ELEVATOR POWER OR

UPSTREAM OF THE ELEVATOR CAB LIGHTS

DISCONNECT.

B. SEE ELEVATOR SCHEDULE ON SHEET A-001

FOR MORE INFORMATION.

C. SEE TECHNOLOGY DRAWINGS FOR FLOOR

ACCESS CONTROL CARD READER

INFORMATION.

COORDINATE

EMERGENCY EXIT

HATCH WITH CAB

CEILING

PROVIDE (8) LED

ILLUMINATED CAR

LIGHT FIXTURES

ABOVE THE CEILING.

MAINTAIN A MINIMUM

LIGHT LEVEL OF 50-

FOOT CANDLES AT

(36") ABOVE THE

FINISHED FLOOR.

PROVIDE S.S.

HANGING CEILING

FRAME. CONSTRUCT

FRAME OF .125" X

1.50" X 1.50" "T" AND

"L" SECTIONS.

A-104 66

6'-0"

HORIZONTAL CONTROL

PANEL

VERTICAL CONTROL PANEL

TOP OF CABCLEAN AND REFINISH

STAINLESS STEEL DOOR,

WALL SURFACE AND DOOR

CONTROLS

1" EQ 1" EQ 1"

NEW STAINLESS STEEL

CEILING

TOP OF CAB

PROVIDE CAR ENCLOSURE WITH

NEW HANDRAILS @ CENTERLINES

OF 42" AND 30" ABOVE THE CAR

FLOOR. MATCH EXIST. SPACING

OF HANDRAIL FROM CAB WALL.

CONCEAL ALL HANDRAIL

FASTENINGS HANDRAILS SHALL

BE REMOVABLE FROM THE INSIDE

OF THE CAR ENCLOSURE.

LOCATE HANDRAILS 1-1/2" FROM

CAB WALL. PROVIDE FLAT STOCK

HANDRAILS WITH THE ENDS AT

THE ENTRANCE TURNED BACK TO

THE WALL.

PANEL TO BE

REMOVED AND

REINSTALLED

PROVIDE CAR ENCLOSURE

WITH NEW HIGH IMPACT

WALLCOVERING, HIW-1

PANELS AND STAINLESS

STEEL TRIM

PROVIDE NEW 8" TALL CRASH RAIL

@8" ABOVE CAR FLOOR.

CONCEAL ALL CRASH RAIL

FASTENINGS. CRASH RAIL SHALL

BE REMOVABLE FROM THE

INSIDE OF THE CAR ENCLOSURE.

PROVIDE FLAT STOCK CRASH

RAILS WITH THE ENDS AT THE

ENTRANCE TURNED BACK TO THE

WALL.

NEW HIGH IMPACT

WALLCOVERING, HIW-2

PANELS AND STAINLESS

STEEL TRIM

PROVIDE NEW STAINLESS

STEEL HOOKS AND ELEVATOR

PADS TO PASSENGER

ELEVATOR CAB ON 3 SIDES

SIGNAGE TO BE

REMOVED AND

REINSTALLED

NEW STAINLESS STEEL BASE

CLEAN AND

REFINISH STAINLESS

STEEL WALL

SURFACES

1" EQ 1" EQ 1" EQ 1" EQ 1"

NEW STAINLESS STEEL CEILING

TOP OF CAB

PROVIDE CAR ENCLOSURE WITH NEW

HANDRAILS @ CENTERLINES OF 42"

AND 30" ABOVE THE CAR FLOOR.

MATCH EXIST. SPACING OF HANDRAIL

FROM CAB WALL. CONCEAL ALL

HANDRAIL FASTENINGS HANDRAILS

SHALL BE REMOVABLE FROM THE

INSIDE OF THE CAR ENCLOSURE.

LOCATE HANDRAILS 1-1/2" FROM CAB

WALL. PROVIDE FLAT STOCK

HANDRAILS WITH THE ENDS AT THE

ENTRANCE TURNED BACK TO THE

WALL.

PROVIDE CAR ENCLOSURE WITH NEW

HIGH IMPACT WALLCOVERING, HIW-1

PANELS AND STAINLESS STEEL TRIM

1" EQ 1" EQ 1"

PROVIDE NEW 8" TALL CRASH RAIL

@8" ABOVE CAR FLOOR. CONCEAL ALL

CRASH RAIL FASTENINGS. CRASH RAIL

SHALL BE REMOVABLE FROM THE

INSIDE OF THE CAR ENCLOSURE.

PROVIDE FLAT STOCK CRASH RAILS

WITH THE ENDS AT THE ENTRANCE

TURNED BACK TO THE WALL.

NEW HIGH IMPACT WALLCOVERING,

HIW-2 PANELS AND STAINLESS STEEL

TRIM

SIGNAGE TO BE

REMOVED AND

TURNED OVER TO VA

REMOVE AND

REINSTALL SIGNAGE

FLOOR INDICATOR TO

REMAIN CLEAN AND

REFURBISH

NEW STAINLESS STEEL BASE

CLEAN AND REFINISH

STAINLESS STEEL WALL

SURFACES

PROVIDE NEW STAINLESS STEEL

HOOKS AND ELEVATOR PADS TO

PASSENGER ELEVATOR CAB ON 3

SIDES

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

Headquarters:

Michael Blades & Associates, Ltd.

5409 Rapidan Ct, Lothian, MD 20711 www.elevatormba.com 410-798-8504© 2020 Michael Blades & Associates, Ltd.

/2

/2

:4

:0

P

M C

U s e rs

\b n e e d h a m

\D o c u m e n ts \A

-1

-V

A C in c in n a ti -E le v a to r

U p g r E le v -O

H b n e e d h a m

H L

.r v t

A-104

BUILDING 1 TYPICAL PASSENGER (P-15

/ P-16) ELEVATOR CAB PLANS AND

INTERIOR ELEVATIONS

6 8BN

UPGRADE ELEVATORS

CINCINNATI VA MEDICAL CENTER

3200 VINE STREET

CINCINNATI, OH, 45220 MARCH 17, 2023

BID DOCUMENTS

539-23-20322-119

JAB

Scale: 1/2" = 1'-0"

BUILDING 1

ELEVATOR CAB REFLECTED CEILING PLAN

(P-15 & P-16)

Scale: 1/2" = 1'-0"

BUILDING 1

ELEVATOR CAB FLOOR PLAN

(P-15 & P-16)

N O

R T

H0 1 2 4

N O

R T

H0 1 2 4

Scale: 3/4" = 1'-0"

BUILDING 1

CAB FRONT INTERIOR ELEVATION

(P-15 & P-16)

Scale: 3/4" = 1'-0"

BUILDING 1

CAB SIDE INTERIOR ELEVATION (2 SIDES)

(P-15 & P-16)

Scale: 3/4" = 1'-0"

BUILDING 1

CAB REAR INTERIOR ELEVATION

(P-15 & P-16) BLDG 1 EXIST. ELEVATOR CAB PHOTO P-150 1 2

0 1 2

0 1 2

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

BLDG

BLDG 1

SIM

BLDG 1 EXIST ELEVATOR CAB PHOTO P-16

1 REMOVE EXISTING FLOORING, HANDRAIL,

WALL PANELS, CEILING AND LIGHTS

A. ALL ELECTRICAL WORK REQUIRED BY

THIS MODIFICATION IS THE

RESPONSIBILITY OF THE ELEVATOR

CONTRACTOR. IF ANY WORK REQUIRES

A LICENSED ELECTRICIAN, THIS SHALL BE

INCLUDED IN THE RESPONSIBILITY OF

THE ELEVATOR COMPANY TO RETAIN

AND PROVIDE SUCH AN INDIVIDUAL IF

NECESSARY. NO WORK IS PROJECTED

TO BE REQUIRED UPSTREAM OF THE

MAIN LINE ELEVATOR POWER OR

UPSTREAM OF THE ELEVATOR CAB

LIGHTS DISCONNECT.

B. PHOTO INDICATES ONE ELEVATOR CAB

FOR DEMOLITION AND NEW WORK, BUT

OVERALL PROJECT INCLUDES ALL CARS

IN THIS BANK OF ELEVATORS.

C. SEE ELEVATOR SCHEDULE ON SHEET

A-001 FOR MORE INFORMATION.

CONTRACTOR SHALL REFER TO THE LIMITED LEAD

PAINT TESTING RESULTS, AT THE END OF

SPECIFICATION SECTION 028313.33, FOR

POTENTIAL LEAD PAINT ABATEMENT WORK. IF

CONTRACTOR DISCOVERS ANY FURTHER LEAD

PAINT AREAS WHEN WORKING ON ELEVATOR CAB

INTERIORS OR CAB FRAMES, THE CONTRACTOR

SHALL NOTIFY THE VA COR IMMEDIATELY FOR

FURTHER INSTRUCTION.

UP

Mech. Room

B15

Stor.

B01A

Transformer Vault

B02 Stor.

B05A

A/c Shop Off.

B05

Glass Wash & Still

B04

Lobby

C*B*08

Elev. Equip.

Room

B03

Stair #1

S*B*1

Research Stor.

B04A

Air Comp

B06

Corridor

B08A

ELEVATOR P-7

A-106

ELEVATORS INCLUDED IN

SCOPE OF WORK

LEGEND

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

Headquarters:

Michael Blades & Associates, Ltd.

5409 Rapidan Ct, Lothian, MD 20711 www.elevatormba.com 410-798-8504© 2020 Michael Blades & Associates, Ltd.

/2

/2

:2

:2

P

M C

U s e rs

\b n e e d h a m

\D o c u m e n ts \A

-1

-V A

C in c in n a ti -E le v a to r U p g r E le v -O

H -B

L G b n e e d h a m

H L

.r v t

A-105

OVERALL BUILDING 15 GROUND FLOOR

PLAN

BN

UPGRADE ELEVATORS

CINCINNATI VA MEDICAL CENTER

3200 VINE STREET

CINCINNATI, OH, 45220 MARCH 17, 2023

BID DOCUMENTS

539-23-20322-119

JAB

Scale: 1/8" = 1'-0"

OVERALL BUILDING 15 GROUND FLOOR PLAN

N O

R T

H0 4 8 16

7 8

A-106

A-106

SIM

VERTICAL CONTROL

PANEL

HORIZONTAL CONTROL

PANEL

6'-0"

COORDINATE

EMERGENCY EXIT

HATCH WITH CAB

CEILING

PROVIDE (6) LED

ILLUMINATED CAR

LIGHT FIXTURES

ABOVE THE CEILING.

MAINTAIN A MINIMUM

LIGHT LEVEL OF 50-

FOOT CANDLES AT

(36") ABOVE THE

FINISHED FLOOR.

PROVIDE S.S.

HANGING CEILING

FRAME. CONSTRUCT

FRAME OF .125" X

1.50" X 1.50" "T" AND

"L" SECTIONS. 7

INSTALL HOISTWAY

ESCUTCHEON TUBES.

CLEAN AND

REFINISH

STAINLESS STEEL

WALL SURFACES

PROVIDE CAR

ENCLOSURE WITH

NEW HIGH IMPACT

WALLCOVERING,

HIW-1 PANELS AND

STAINLESS STEEL

TRIM

PROVIDE NEW

STAINLESS STEEL

HOOKS AND

ELEVATOR PADS TO

PASSENGER

ELEVATOR CAB ON 3

SIDES

NEW STAINLESS STEEL

CEILING ; MATCH EXISTING

CEILING HEIGHT

TOP OF CAB

PROVIDE CAR ENCLOSURE WITH

NEW HANDRAILS @ CENTERLINES

OF 42" AND 30" ABOVE THE CAR

FLOOR. MATCH EXIST. SPACING

OF HANDRAIL FROM CAB WALL.

CONCEAL ALL HANDRAIL

FASTENINGS HANDRAILS SHALL

BE REMOVABLE FROM THE INSIDE

OF THE CAR ENCLOSURE. LOCATE

HANDRAILS 1-1/2" FROM CAB

WALL. PROVIDE FLAT STOCK

HANDRAILS WITH THE ENDS AT

THE ENTRANCE TURNED BACK TO

THE WALL.

NEW HIGH IMPACT

WALLCOVERING, HIW-2

PANELS AND STAINLESS

STEEL TRIM

PROVIDE NEW 8" TALL CRASH

RAIL @ 8" ABOVE CAR FLOOR.

CONCEAL ALL CRASH RAIL

FASTENINGS. CRASH RAIL SHALL

BE REMOVABLE FROM THE

INSIDE OF THE CAR ENCLOSURE.

PROVIDE FLAT STOCK CRASH

RAILS WITH THE ENDS AT THE

ENTRANCE TURNED BACK TO

THE WALL.

NEW STAINLESS STEEL

BASE

1" EQ 1" EQ 1" EQ 1"

NEW STAINLESS STEEL

CEILING; MATCH EXISTING

CEILING HEIGHT

TOP OF CAB

PROVIDE CAR ENCLOSURE WITH

NEW HANDRAILS @ CENTERLINES

OF 42" AND 30" ABOVE THE CAR

FLOOR. MATCH EXIST. SPACING OF

HANDRAIL FROM CAB WALL.

CONCEAL ALL HANDRAIL

FASTENINGS HANDRAILS SHALL BE

REMOVABLE FROM THE INSIDE OF

THE CAR ENCLOSURE. LOCATE

HANDRAILS 1-1/2" FROM CAB WALL.

PROVIDE FLAT STOCK HANDRAILS

WITH THE ENDS AT THE ENTRANCE

TURNED BACK TO THE WALL.

PANEL TO BE REMOVED

AND REINSTALLED

PROVIDE CAR ENCLOSURE

WITH NEW HIGH IMPACT

WALLCOVERING, HIW-1

PANELS AND STAINLESS

STEEL TRIM

1" EQ 1" EQ 1"

PROVIDE NEW 8" TALL CRASH

RAIL @ 8" ABOVE CAR FLOOR.

CONCEAL ALL CRASH RAIL

FASTENINGS. CRASH RAIL SHALL

BE REMOVABLE FROM THE

INSIDE OF THE CAR ENCLOSURE.

PROVIDE FLAT STOCK CRASH

RAILS WITH THE ENDS AT THE

ENTRANCE TURNED BACK TO

THE WALL. 8

NEW HIGH IMPACT

WALLCOVERING, HIW-2

PANELS AND STAINLESS

STEEL TRIM

PROVIDE NEW STAINLESS

STEEL HOOKS AND

ELEVATOR PADS TO

PASSENGER ELEVATOR CAB

ON 3 SIDES

SIGNAGE TO BE REMOVED

AND RE INSTALLED

NEW STAINLESS STEEL

BASE

CLEAN AND REINISH STAINLESS

STEEL DOOR, WALL SURFACE

AND DOOR CONTROLS

TOP OF CAB

REPLACE

EMERGENCY

PHONE

CLEAN AND REFINISH

STAINLESS STEEL

SURFACES ON THE

FRONT OF THE CAB,

DOORS AND

CONTROLS.

1" EQ 1" EQ 1" EQ 1"

BLDG 15 EXIST. ELEVATOR CAB PHOTO P-7

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

Headquarters:

Michael Blades & Associates, Ltd.

5409 Rapidan Ct, Lothian, MD 20711 www.elevatormba.com 410-798-8504© 2020 Michael Blades & Associates, Ltd.

/2

/2

:2

:2

P

M C

U s e rs

\b n e e d h a m

\D o c u m e n ts \A

-1

-V A

C in c in n a ti -E le v a to r U p g r E le v -O

H -B

L G b n e e d h a m

H L

.r v t

A-106

BUILDING 15 PASSENGER ELEVATOR

P-7 ENLARGED FLOOR PLAN AND

INTERIOR ELEVATIONS

BN

UPGRADE ELEVATORS

CINCINNATI VA MEDICAL CENTER

3200 VINE STREET

CINCINNATI, OH, 45220 MARCH 17, 2023

BID DOCUMENTS

539-23-20322-119

JAB

Scale: 1/2" = 1'-0"

BUILDING 15

ELEVATOR CAB FLOOR PLAN

(P-7)

Scale: 1/2" = 1'-0"

BUILDING 15

ELEVATOR CAB REFLECTED CEILING PLAN

(P-7)

N O

R T

H0 4 8 16

8 8

Scale: 3/4" = 1'-0"

BUILDING 15

TYPICAL DOOR ELEVATION

(P-7)

N O

R T

H0 4 8 160 1 2

Scale: 3/4" = 1'-0"

BUILDING 15

CAB REAR INTERIOR ELEVATION

(P-7)

Scale: 3/4" = 1'-0"

BUILDING 15

CAB SIDE INTERIOR ELEVATION (2 SIDES)

(P-7)

Scale: 3/4" = 1'-0"

BUILDING 15

CAB FRONT INTERIOR ELEVATION

(P-7) 0 1 20 1 20 1 2

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

BLDG

BLDG 1

1 REMOVE EXISTING FLOORING, HANDRAIL, WALL

PANELS, CELING AND LIGHTS

A. ALL ELECTRICAL WORK REQUIRED BY THIS

MODIFICATION IS THE RESPONSIBILITY OF

THE ELEVATOR CONTRACTOR. IF ANY

WORK REQUIRES A LICENSED

ELECTRICIAN, THIS SHALL BE INCLUDED IN

THE RESPONSIBILITY OF THE ELEVATOR

COMPANY TO RETAIN AND PROVIDE SUCH

AN INDIVIDUAL IF NECESSARY. NO WORK IS

PROJECTED TO BE REQUIRED UPSTREAM

OF THE MAIN LINE ELEVATOR POWER OR

UPSTREAM OF THE ELEVATOR CAB LIGHTS

DISCONNECT.

B. SEE ELEVATOR SCHEDULE ON SHEET

A-001 FOR MORE INFORMATION.

L L

SPKR SPEAKER

SP SPARE

SR SURFACE RACEWAY

SS STAINLESS STEEL

SSW SELECTOR SWITCH

STD STANDARD

SURF SURFACE MOUNTED

SW SWITCH

SWBD SWITCHBOARD

SYM SYMMETRICAL

SYS SYSTEM

TC TIMECLOCK

TEL TELEPHONE

TEL/DATA TELEPHONE/DATA

TERM TERMINAL

TP TWISTED PAIR

TPS TWISTED PAIR SHIELDED

TR TAMPER RESISTANT

T-STAT THERMOSTAT

TTB TELEPHONE TERMINAL BOARD

TTC TELEPHONE TERMINAL CABINET

TV TELEVISION

TYP TYPICAL

UC UNDER COUNTER

UE UNDERGROUND ELECTRICAL

UG UNDERGROUND

UH UNIT HEATER

UL UNDERWRITER'S LABORATORY

UT UNDERGROUND TELEPHONE

UTP UNSHIELDED TWISTED PAIR

UTIL UTILITY

UV UNIT VENTILATOR OR

ULTRAVIOLET

V VOLT

VA VOLT-AMPERES

VERT VERTICAL

VFD VARIABLE FREQUENCY DRIVE

VOL VOLUME

W WATT

W/ WITH

WH WATER HEATER

W/O WITHOUT

WP WEATHERPROOF

XFMR TRANSFORMER

XFR TRANSFER

ANGLE

@ AT

DELTA

' FEET

" INCHES

# NUMBER

Φ PHASE

C CENTER LINE

P PLATE

MTR MOTOR, MOTORIZED

MTS MANUAL TRANSFER SWITCH

NA NOT APPLICABLE

NC NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURER'S ASSOCIATION

NFDS NON-FUSED SAFETY DISCONNECT

SWITCH

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NORMALLY OPEN

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OH OVERHEAD

OL OVERLOAD

PA PUBLIC ADDRESS

PB PULL BOX OR PUSHBUTTON

PBPU PREFABRICATED BEDSIDE PATIENT

UNIT

PCB POLYCHLORINATED BIPHENYL

PC PHOTOELECTRIC CELL

PED PEDESTAL

PEND PENDANT

PF POWER FACTOR

PH PHASE

PIV POST INDICATING VALVE

PNL PANEL

POE POWER-OVER-ETHERNET

PR PAIR

PRI PRIMARY

PROJ PROJECTION

PRV POWER ROOF VENTILATOR

PT POTENTIAL TRANSFORMER

PVC POLYVINYL CHLORIDE (CONDUIT)

PWR POWER

QTY QUANTITY

R RELOCATE/RELOCATED

RCP REFLECTED CEILING PLAN

RCPT RECEPTACLE

REQD REQUIRED

RGS RIGID GALVANIZED STEEL

RM ROOM

RMS ROOT MEAN SQUARE

RTU ROOF TOP UNIT

SC SURFACE CONDUIT

SEC SECONDARY

SF SQUARE FEET/FOOT

SHT SHEET

SI INTERNATIONAL SYSTEM OF UNITS

SIM SIMILAR

S/N SOLID NEUTRAL

SPEC SPECIFICATION

1P 1 POLE (2P, 3P, 4P, ETC.)

1PH 1 PHASE

2/C TWO-CONDUCTOR (3/C, 4/C, ETC.)

2W TWO-WIRE (3W, 4W, ETC.)

3PH 3 PHASE

A AMPERE

AAP ALARM ANNUNCIATOR PANEL

AC ABOVE COUNTER

AIR CONDITIONER

ALTERNATING CURRENT

ACC ACCESSIBLE

ACLG ABOVE CEILING

ADO AUTOMATIC DOOR OPENER

A/E ARCHITECT/ENGINEER

AF AMP FRAME

AFC AVAILABLE FAULT CURRENT (KILOAMPS)

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFI ARC FAULT CIRCUIT INTERRUPTER

AHJ AUTHORITY HAVING JURISDICTION

AHU AIR HANDLING UNIT

AIC AMPERE INTERRUPTING CAPACITY

AL ALUMINUM

ALT ALTERNATE

AMP AMPERE

APPROX APPROXIMATELY

ARCH ARCHITECT, ARCHITECTURAL

AT AMP TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIO VISUAL

AWG AMERICAN WIRE GAUGE

BAS BUILDING AUTOMATION SYSTEM

BATT BATTERY

BC BARE COPPER

BD BOARD

BFF BELOW FINISHED FLOOR

BLDG BUILDING

BMS BUILDING MANAGEMENT SYSTEM

BYP BYPASS

C CONDUIT

CAB CABINET

CALC CALCULATED

CAP CAPACITY

CAT CATALOG, CATEGORY

CATV COMMUNITY ANTENNA TELEVISION

CB CIRCUIT BREAKER

CCR CONTROL CONTACTOR

CCT CORRELATED COLOR TEMPERATURE

CCTV CLOSED CIRCUIT TELEVISION

cd CANDELA

CD CONSTRUCTION…