210129_Drawings_03.29.2024.pdf
PDF 2 MB Posted
- Solicitation number
- FA813725R0049
About this file
These mechanical engineering design drawings document the HVAC Control System Repair Facility project for Tinker Air Force Base in Oklahoma, Project Number WWYK210129. The drawings cover a comprehensive mechanical layout across multiple floors (ground floor, second floor, and roof level) for Building B2122, detailing the precise placement of numerous mechanical equipment units including air handling units (AHUs), make-up air units (MAUs), exhaust fans (EFs), control units (CUs), and various electrical panels and transformers. The design is a concept-level mechanical layout showing the spatial arrangement and distribution of HVAC infrastructure, with a key focus on providing mechanical systems for a repair facility, including specialized areas like ejection rooms, dock entrances, tool cribs, and mechanical rooms. The drawings include detailed zone maps, equipment location specifics, and a vicinity map showing the project's location within Tinker Air Force Base.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 210129_ATT9_8A_DESIGN-BUILD_SOW_v6.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REVIEWED BY:
REVIEWED BY:
USING AGENCY:
ASBESTOS EVALUATION:
SAFETY:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
INDUSTRIAL HYGIENE:
DATE:
PROJECT DRAWING INDEX SIGNATURES
CORROSION ENGINEER: (CECE)
CE OPERATIONS: (CECO)
COMMUNICATIONS: (COMM)
CHIEF ENGINEER DIR: (CECE)
CHIEF DESIGN BRANCH: (CECE)
DESIGN MANAGER: (CECE)
ZONE MANAGER:
CONSTRUCTION MANAGEMENT: (CECE)
ENVIRONMENTAL:
BASE CIVIL ENGINEER: (CE)
FIRE DEPARTMENT: (CEFT)
GENERAL1. BRAND NAMES: REFERENCE TO SPECIFIC BRAND NAMES
OR COMPANIES IS FOR THE PURPOSE OF ESTABLISHING
MINIMUM QUALITY STANDARDS, IDENTIFICATION AND
GUIDANCE AND IS NOT INTENDED TO LIMIT SELECTION OF
OTHER MANUFACTURERS THAT ARE EQUAL OR EXCEED
THE SPECIFIED ITEMS IN TERMS OF PHYSICAL
PROPERTIES, INCLUDING, COLOR RANGE, FINISH,
DURABILITY, APPEARANCE, PERFORMANCE
CHARACTERISTICS, AND OTHER FACTORS. OTHER
PRODUCTS, MATERIALS, COLORS AND SYSTEMS, MAY BE
SUBMITTED FOR EVALUATION AND
APPROVAL/DISAPPROVAL BY THE CONTRACTING OFFICER.
2. THIS SET OF CONSTRUCTION DOCUMENTS SHALL BE
CONSIDERED AS A WHOLE IN THAT THE GENERAL
CONTRACTOR AND ALL THE SUB-CONTRACTORS ARE
RESPONSIBLE FOR THE INFORMATION PRESENTED ON ALL
SHEETS ON THE SET OF DRAWINGS AND ALL SECTIONS OF
THE SPECIFICATIONS.
3. THE CONTRACTOR IS RESPONSIBLE FOR ERECTING ALL
CONSTRUCTION FENCING AND BARRICADES AS REQUIRED
TO PROTECT CONSTRUCTION MATERIAL AND TO PREVENT
ANY UNAUTHORIZED PERSONNEL FROM ENTERING THE
CONSTRUCTION SITE.
4. ANY DAMAGE TO THE EXISTING GROUNDS OR FACILITIES
CAUSED BY CONSTRUCTION TRAFFIC OR ANY
CONSTRUCTION OPERATION SHALL BE REPAIRED OR
REPLACED BY THE CONTRACTOR TO MATCH OR EXCEED
EXISTING CONDITIONS AT NO ADDITIONAL COST TO THE
GOVERNMENT.
5. ALL WORK NOTED & LOCATED IN THESE DOCS SHALL BE
UNDERSTOOD BY THE CONTRACTOR TO REQUIRE ALL NEW
LABOR & MATERIALS UNLESS SPECIFICALLY NOTED TO BE
"EXISTING" OR "BY OTHERS".
WWYK210129
REPAIR FACILITY HVAC
CONTROL SYSTEM, B2122
KEY PLAN:
GENERAL NOTES:
PROJECT
LOCATION
1 G-101 GENERAL NOTES & VICINITY MAP
SHT.SEQ. SHEET TITLE
OF
TI
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
CONCEPT
W W
YK
RE
PA
IR
F
AC
ILI
TY
H
VA
C
CO
NT
RO
L S
YS
TE
M, B
XX
X TE
PA
-C
SA
G
S
SE
XT
O
N
G-101
K
FR
EE
M
AN
J W
H
EE
LE
R
En gr
\D es ig n\ s\
\2
9\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
GE
NE
RA
L N
OT
ES
AN
D
VI
CI
NI
TY
M
AP
01 05
DISCIPLINE
M-101 PARTIAL GROUND FLOOR MECHANICAL HVAC LAYOUT
M-102 M-103
PARTIAL SECOND FLOOR MECHANICAL HVAC LAYOUT
PARTIAL ROOF LEVEL MECHANICAL HVAC LAYOUT
M-100 OVERALL GROUND FLOOR MECHANICAL HVAC LAYOUT
RU
NW
AY
/36
RUNWAY 13/31
TA
XI
W
AY
G
TAXIW
AY H
TAXIWAY B
TAXIWAY C
TAXIWAY M
TA
XI
W
AY
K
TAXIWAY E
TAXIWAY A
TA
XIW
AY EE
TAXIWAY F
TAXIWAY D
TAXIWAY E
TAXIWAY J
TA
XI
W
AY
G
TAXIWAY A
TAXIW
AY H
TAXIWAY C
TAXIWAY D
TAXIWAY EE
TAXIWAY F
Elm Creek
Crutcho Creek
Kuhlman Creek
Kuhlman Creek
Elm Creek
East Crutcho Creek
Elm Creek
El m
Cr ee k
Elm Creek
Elm Creek
Elm Creek
Elm Creek
Ku hlm an Cr ee k
Ea st
Cr utc ho C ree k
Elm Cree k
West Crutcho Creek W es t C ru tch o C re ek
Elm Creek
Soldier Creek
Elm Creek
Soldier Creek
Soldier Creek
Ea st
Cr utc ho C re ek
Elm Creek
Ea st
Cr utc ho C re ek
East Crutcho Creek
Soldier Creek
So ldi er Cr ee k
East C rutcho Creek
Soldier Creek
Soldier Creek
So ldi er C re ek
East Crutcho Creek
416506
11401128
59035909
838837
62509
62512
62525
99999
62543
71086
53902
50414
55300
56601
61019
62501
45134
62503
61289
62542
15904
15908
15904
15908
62502
41046
62501
62514
62501
41157
45815
40592
62522
15930
11824
3 10
62540
61089
62528
62523
62501X
43774
62516
3592135916
32101
930G
948-E
911-E
948-W
911-W
33001
35913
65672
930S
43609
42116
62517
62515
62526
62527
62513
62501OK
11289
62501
15930
15908
15904
15908
15904
61018
71089
45134
96022
43120
44045
43610
41163
15930
Ea st
Dr
SE 59th St.
St aff
D r.
5th Ave
W ar eh ou se R d.
7th St.
Mc Na rn ey
A ve
Mitchell Ave
Co ok
A ve
W es t D r.
Extender Dr.
5th Ave.
Globemaster Dr.
Ai r D ep ot
Mercury Rd.
Po nd
R d.
"C " A ve
Hi llto p R d.
"M " A ve
Doolittle Ave
W hit e D r.
Ba ll P ar k R d.
6th St.
Po we rh ou se D r.
Int ru de r D r.
Holden Dr.
Vanaman Rd.
1st St.
Arnold St.
SE 74th St
Ai r D ep ot
Patrol Rd.
Reserve Rd.
"A " A ve
Mu nit ion s R d.
"B " A ve
"H " A ve
Al er t R d.
"E "A ve
Sentry Rd.
34th St.
Twining Dr.
Jo ne s
To we r R d.
Vanaman Rd.
Ind us tria l B lvd
So uth
S t.
1st St.
Do oli ttle A ve
Pi cn ic Rd
Ja me s D r.
W olf e D r.
Ai r D ep ot
"D " A ve
Perimeter Rd.
Rapcon Rd.
Reserve Rd
"L " A ve
"F " A ve
1st St.
Br ow n D r.
Ol d A ir D ep ot
Airey Dr.
General Motors Dr
Bradley Dr.
Entrance Road "C"
Entrance Road "A"
"C " A ve
Vandenberg Dr.
Do rm ito ry
Rd
Dormitory Rd.
Chennault Dr.
Mi tch ell A ve
Spaatz Dr.
Co mm od ity
D r.
3rd Ave.
"D " D riv e
Joint STARS Dr.
Ai r D ep ot
Bl vd
Turbine Dr. Turbine Dr.
Central Plant Dr.
6th St.
Falcon Dr.
Blac kbi rd D r.
W ey lan d L oo p
Pegasus Dr.
Thunderbolt D r.
Munitions Rd. Ext.
Codding Rd.
Starlifter Dr.
Chidlaw Ct.
Co rsa ir D r.
Rap tor
Ct.
Ni gh t H aw k C t.
Ph an tom D r.
Fr an kli n
Sk ym as ter
D r.
Spaatz Ct.
La wr en ce
Mu nd ell
Nabors Dr.
Mc Ni ck le
Mi lle r D r.
Ta il F ea the r D r.
Air ey
Ci r.
Smith Ct. Raven Ct.
Air Dep ot
Ai r D ep ot
1st St.
TAXIWAY F
Ra w li ng s A ve
Mitc he ll A ve
Mercury Rd.
Ra ily ar d R d.
He rcu les R d.
Globemaster Dr.
Pr op uls ion
D r.
Stratofortress Dr.TINKER AFB, OK
VICINITY MAP
BASE
OPERATIONS
B240
CONTRACTING
B3
GOTT
GATE
TINKER GATE
PASS & ID B6611
HRUSKOCY
GATE
EAKER GATE
FIRE DEPARTMENT
B117
VANCE
GATE
LIBERATOR GATE
HOPE
GATE
LEGEND
CONTRACTOR
HAUL ROUTE
LANCER
GATE
TRUCK GATE
PIAZZA GATE
BASE CIVIL
ENGINEER
B400
PROJECT
LOCATION
2280 2211
OF
TI
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
CONCEPT
W W
YK
RE
PA
IR
F
AC
ILI
TY
H
VA
C
CO
NT
RO
L S
YS
TE
M, B
XX
X TE
PA
-C
SA
G
S
SE
XT
O
N
M-100
K
FR
EE
M
AN
J W
H
EE
LE
R
En gr
\D es ig n\ s\
\2
9\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
OV
ER
AL
L G
RO
UN
D
FL
OO
R
ME
CH
AN
IC
AL
H
VA
C
LA
YO
UT
02 05
M-100
OVERALL GROUND FLOOR MECHANICAL HVAC LAYOUT
SCALE: 1/32" = 1'-0"
B2122 KEYPLAN
GENERAL NOTES
1. THE DRAWING WAS PREPARED FROM EXISTING DRAWINGS AND LIMITED ACCESS
FOR FIELD OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS FOR ACCURACY.
A B
C D
E F
G
26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
71 2"
HV
AC
PA
D
HV
AC
PA
D
HV
AC
PA
D
91 2"
HV
AC
PA
D
7"
HV
AC
PA
D
7"
HV
AC
PA
D
7"
HV
AC
PA
D
8"
HV
AC
PA
D
HV
AC
PA
D
1'-
HV
AC
PA
D
EQ
UI
P
PA
D
31 2"
TRANSFORMER
PAD
71 2" 71 2" 7"
71 2"
AI
SL
E
UP
UP UP
TO
OL
C
RI
B
UP
MO
TO
R
CO
NT
RO
L
DR
SINK
SH
OW
ER
SH
OW
ER
SINK
SINK
BE
NC
H
BE
NC
H
BE
NC
H
BE
NC
H
BE
NC
H
BE
NC
H
BE
NC
H
BE
NC
H
BE
NC
H
BE
NC
H BENCH
BENCH
UP
SH
OW
ER
SH
OW
ER
RAMP
SINK
SI
NK
SI
NK
SH
OW
ER
SH
OW
ER
SH
OW
ER
SH
OW
ER
SH
OW
ER
SH
OW
ER
SH
OW
ER
BL
OC
KE
D
DO
OR
SH
OW
ER
SH
OW
ER
BL
OC
KE
D
DO
OR
S
SINK
6" P
AD
SL
OP
E
SL
OP
E
6" C
UR
B
INDUSTRIAL WASTE TRENCH
INDUSTRIAL WASTE TRENCH
INDUSTRIAL WASTE TRENCH
INDUSTRIAL WASTE TRENCH
TA
NK
CO
MP
UT
ER
RO
OM
E.
D
OC
K
EN
TR
AN
CE
ME
CH
AN
IC
AL
R
OO
M
ME
CH
AN
IC
AL
R
OO
M
ME
CH
AN
IC
AL
R
OO
M
ME
CH
AN
IC
AL
R
OO
M
OF
FI
CE
B- 1 P
RO
DU
CT
IO
N
RO
OM
A
TO
OL
C
RI
B
BREAK ROOM
ME
N
WOMEN
CL
OS
ET
EL
EC
TR
IC
AL
VA
UL
T
MECH
EJ
EC
TI
ON
RO
OM
I
ND
I R
EC
EI
VI
NG
B
AY
BR
EA
K
RO
OMEJ
EC
TI
ON
RO
OM
A
EJ
EC
TI
ON
RO
OM
B
B-
E
JE
CT
IO
N
RO
OM
C
EJ
EC
TI
ON
RO
OM
F
SC
HE
DU
LIN
G
OF
FI
CE
OF
FI
CE
ME
N'
S
LO
CK
ER
RO
OM
TO
OL
C
RI
B
TO
OL
C
RI
B
CL
OS
ET
CL
OS
ET
UN
DE
R
CO
NS
TR
UC
TI
ON
TOOL CRIB
B-1 PRODUCTION
ROOM B
DI
SA
SS
EM
BL
Y
CL
EA
NI
NGCA
FE
TE
RI
A
SA
ND
BL
AS
TE
R
ME
N
ME
N
W
OM
EN
CL
OS
ET
CL
OS
ET
B1 LRU STORAGE ROOM
RE
GU
LA
TO
R
RO
OMW
ES
T
DO
CK
OF
FI
CE
MA
TE
RI
AL
R
OO
M
BR
EA
K
RO
OM
CA
GE
W
OM
EN
'S
LO
CK
ER
R
OO
M
B1
LO
CK
ER
R
OO
M
B1 AVIONICS BACK SHOP
AV
IO
NI
CS
CD
DS
R
OO
M
B- 1B
A
IR
CR
AF
T
SH
EE
T
ME
TA
L B
AC
K
SH
OP
VA
UL
T
B1-B LANDING
GEAR SHOP
B-1B MLG
MATERIAL
TAIL BIN
EJ
EC
TI
ON
RO
OM
G
EJ
EC
TI
ON
RO
OM
H
OF
FI
CE
B1 E
JE
CT
IO
N
RO
OM
D
UN
DE
R
CO
NS
TR
UC
TI
ON
UN
DE
R
CO
NS
TR
UC
TI
ON
W
OM
EN
CL
OS
ET
ME
N
CO
MM
R
OO
M
POST DOCK
AVIONICS
POST DOCK
MEETING ROOMCO
MM
R
OO
M
BR
EA
K
RO
OM
OF
FI
CE
BA
CK
SH
OP
OFFICE
CL
OS
ET
CHEM
STORAGE
W
OM
EN
'S
LO
CK
ER
RO
OM
DI
SA
SS
EM
BL
Y
CL
EA
NI
NG
OF
FI
CE
DI
SA
SS
EM
BL
Y
CL
EA
NI
NG
OF
FI
CE
SO
UT
H
EX
PO
SU
RE
RO
OM
NO
RT
H
EX
PO
SU
RE
RO
OM
NDI
PROCESSING NDI VIEWING
CHEMICAL
STORAGE ROOM
B1 PLANNING AREA
WOMEN'S LOCKER ROOM
EQ
UI
PM
EN
T
RO
OM
EQ
UI
PM
EN
T
RO
OM
EQ
UI
PM
EN
T
RO
OM
ME
N
EN
TR
Y
TO
W
ES
T
DO
CK
SE
RV
IC
IN
G
SE
CT
IO
N
B1-B MIC
HA
ZM
AT
DI
SP
OS
AL
NV
NV
NV
AI
SL
E
AI
SL
E
AI
SL
E
AI
SL
EAI
SL
E
6" C
UR
B
DOCK BOX 1
DOCK BOX 2
DOCK BOX 3 DOCK BOX 4
UT
ILI
TY
T
UN
NE
L
UT
ILI
TY
T
UN
NE
L
UT
ILI
TY
T
UN
NE
L
UT
ILI
TY
T
UN
NE
L
SA
ND
BL
AS
TE
R
SE
LF
C
LE
AN
ER
NV
CO
/O
2 S
EN
SO
RS
CO
/O
2 S
EN
SO
RS
CO
/O
2 S
EN
SO
RS
CO
/O
2 S
EN
SO
RS
ELEV
BAY 1 BAY 2 BAY 4BAY 3
WEST
DOCK
CENTER
DOCK
EAST
DOCK
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 5026 27 28 29 30 31
INDUSTRIAL WASTE TRENCH
INDUSTRIAL WASTE TRENCH
Au toc lav e
Eq uip
W ate rje t S ys tem
Eq uip
Au toc lav e
Eq uip
UH-N01UH-N02UH-N03
UH
-N
UH-N05
UH
-N
UH-N07
UH
-N
UH-N09UH-N10UH
-N
UH
-N
UH-N13 UH-N14
UH-N15
UH-N17
UH
-N
UH-N19
UH
-N
UH-N20 UH-N21 UH-N23
UH
-N
UH-N24 UH-N25
UH
-N
UH
-N
BFRP-3
PLS-3
BFRP-1
PLS-4
PLS-1
MAU-9
BFRP-4
CU-25
EF-25 EF-24
EF-7
CU-M11
EF-6EF-5
UH-N28
PSFS-5 PSFS-6
PSFS-8 PSFS-9 PSFS-10
CH-1
EF-13
EF-26
BFRP-6
WH-2WH-1
WS-1
PC
W
-3
PC
W -4
PHW-2
PHW-1
PCHW-1
PCHW-2
BLR-1
AHU-15
AHU-18
EF-30
PKG-1
DSFD-31
CU-19
AHU-19
DSFD-17
DSFD-16
AHU-22
MAU-13DSFD-1
BFRP-8
EF-29
EF-28
UH-3
DSFD-30
DSFD-10 DSFD-11
DSFD-12
UH-2
EF-14
DSFD-13
DSFD-23 DSFD-29
EF-22
DSFD-7
DSFD-8
UH-1
DSFD-22
AHU-23
AHU-20
MAU-16
MA
U-
DSFD-5DSFD-6
DSFD-3
DSFD-2
DSFD-4
DSFD-19
DSFD-18
EF-23
WH-3
WH-4
WH-5
PSFS-1
PSFS-2 PSFS-3
DSFD-20
DSFD-21
AH
U-
BFRP-5
EF-`1 EF-2 EF-3 EF-4 EF-8 EF-9 EF-10
AHU-26AHU-27
CU-26
CU-27
2122-OWS-1
PSCW-1PSCH-1
PSHW-1
MAU-12
AHU-21
MA
U-
PSFS-4
BS
TR
-1
BS
TR
-2
CNTR-C1
CNTR-B1
DSFD-15
DSFD-24
EF-15
AH
U-
WH-6
ACF-1
ACF-3
ACF-5
ACF-2
ACF-4
ACF-6
MAU-11
CNTR-M11
AHU-3
CNTR-3
AHU-25
MA
U-
MAU-5MAU-3 MAU-8
CNTR-M08
BFRP-2EF-27
DSFD-9
MAU-17
DSFD-32
DSFD-33
DSFD-14
EF-31
BL
R-
HW
CNTR-BLR-HW01
CNTR-BLR-HW02
BL
R-
HW
PHW-3
PHW-4
TNK-12
EF-33EF-32
PLS-2
BLR-1
PSHW-2
PSHW-1
VFD-PHWS01
VFD-PHWSO2UH-B01
CNTR-BLR-1
LAV-1-W1
LAV-1-M3
LA
V-
1- M4
LAV-1-W2
LAV-1-M2
LA
V-
1- W
SHR-1-M4 SHR-1-W3
SHR-1-W1
SH
R-
1-
ML
RS SH
R-
1- W
SNK-1
SNK-1-1
SNK-2
SNK-3
SNK-4
SNK-6
SNK-7
SNK-8
TNK-1
TNK-2
TNK-3
URN-1-M2
WC-1-M2
WC-1-W1
URN-1-M3
WC-1-M3
WC-1-W2
UR
N-
1- M4
W C-
1- M4
W C-
1- W
WU-01
WU-02WU-03
WU-04 W
U-05
WU-06
WU-07
WU-08 WU-09
WU-12WU-13WU-14WU-15
VF
D-
1.1
VF
D-
1.2
VF
D-
1.3
VF
D-
1.4
VF
D-
2.1
VF
D-
2.2
VF
D-
2.3
VF
D-
2.4
MAU-4 MAU-7
CNTR-M07
MAU-6
CNTR-M06
AHU-9
CNTR-9
CNTR-11
AHU-11 CNTR-12
AHU-12 CNTR-13
AHU-13
AHU-16
CNTR-16
CNTR-5
AHU-5
CNTR-14
AHU-14
26 27 28 29
37 38 39 40 41 42 43 44 45 46 47 48 49 50
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
CONCEPT
W W
YK
RE
PA
IR
F
AC
ILI
TY
H
VA
C
CO
NT
RO
L S
YS
TE
M, B
XX
X TE
PA
-C
SA
G
S
SE
XT
O
N
M-101
K
FR
EE
M
AN
J W
H
EE
LE
R
En gr
\D es ig n\ s\
\2
9\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
PA
RT
IA
L
GR
OU
ND
F
LO
OR
ME
CH
AN
IC
AL
H
VA
C
LA
YO
UT
03 05
M-101
PARTIAL GROUND FLOOR MECHANICAL HVAC WEST LAYOUT
SCALE: 1/16" = 1'-0"
M-101
PARTIAL GROUND FLOOR MECHANICAL HVAC EAST LAYOUT
SCALE: 1/16" = 1'-0"
B2122 KEYPLAN
GENERAL NOTES
1. THE DRAWING WAS PREPARED FROM EXISTING DRAWINGS AND LIMITED ACCESS
FOR FIELD OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS FOR ACCURACY.
UP
UP UP
TO
OL
C
RI
B
UP
MO
TO
R
CO
NT
RO
L
DR
SINK
SH
OW
ER
SH
OW
ER
SINK
SINK
SI
NK
SH
OW
ER
SH
OW
ER
SH
OW
ER
SH
OW
ER
SH
OW
ER
SH
OW
ER
SH
OW
ER
BL
OC
KE
D
DO
OR
S
SL
OP
E
6" C
UR
B
NV
NV
INDUSTRIAL WASTE TRENCHINDUSTRIAL WASTE TRENCH
TA
NK
E.
D
OC
K
EN
TR
AN
CE
B- 1 P
RO
DU
CT
IO
N
RO
OM
A
TO
OL
C
RI
B
BREAK ROOM
ME
N
WOMEN
CL
OS
ET
EL
EC
TR
IC
AL
VA
UL
T
MECH
EJ
EC
TI
ON
RO
OM
I
ND
I R
EC
EI
VI
NG
B
AY
BR
EA
K
RO
OMEJ
EC
TI
ON
RO
OM
A
EJ
EC
TI
ON
RO
OM
B
B-
E
JE
CT
IO
N
RO
OM
C
EJ
EC
TI
ON
RO
OM
F
SC
HE
DU
LIN
G
OF
FI
CE
OF
FI
CE
ME
N'
S
LO
CK
ER
RO
OM
TO
OL
C
RI
B
TO
OL
C
RI
B
CL
OS
ET
CL
OS
ET
UN
DE
R
CO
NS
TR
UC
TI
ON
TOOL CRIB
B-1 PRODUCTION
ROOM B
CA
GE
EJ
EC
TI
ON
RO
OM
G
EJ
EC
TI
ON
RO
OM
H
OF
FI
CE
B1 E
JE
CT
IO
N
RO
OM
D
UN
DE
R
CO
NS
TR
UC
TI
ON
UN
DE
R
CO
NS
TR
UC
TI
ON
CHEM
STORAGE
SO
UT
H
EX
PO
SU
RE
RO
OM
NO
RT
H
EX
PO
SU
RE
RO
OM
NDI
PROCESSING NDI VIEWING
CHEMICAL
STORAGE ROOM
B1 PLANNING AREA
WOMEN'S LOCKER ROOM
EQ
UI
PM
EN
T
RO
OM
EQ
UI
PM
EN
T
RO
OM
EQ
UI
PM
EN
T
RO
OM
ME
N
HA
ZM
AT
DI
SP
OS
AL
NV
NV
AI
SL
EAI
SL
E
6" C
UR
B
DOCK BOX 3 DOCK BOX 4
NV
NV
ELEV
UH-N01UH-N02UH-N03
CH-1
EF-13
EF-26
BFRP-6
WS-1
PC
W
-3
PC
W
-4
PCHW-1
PCHW-2
BLR-1
DSFD-17
DSFD-16
BFRP-8
EF-29
EF-28
UH-3
DSFD-30
DSFD-10 DSFD-11
DSFD-12
UH-2
EF-14
DSFD-13
DSFD-23 DSFD-29
EF-22
DSFD-7
DSFD-8
UH-1
DSFD-22
AHU-23
AHU-20
MAU-16
MA
U-
DSFD-5DSFD-6
DSFD-4
DSFD-19
DSFD-18
EF-23
WH-3
WH-4
PSFS-3
DSFD-20
DSFD-21
AH
U-
BFRP-5
AHU-26AHU-27
CU-26
CU-27
PSCW-1
PSCH-1
PSHW-1
MA
U-
PSFS-4
BS
TR
-1
BS
TR
-2
CNTR-C1
CNTR-B1
DSFD-15
AH
U-
BFRP-2
DSFD-9
DSFD-14
EF-31LAV-1-M3
LAV-1-W2
SH
R-
1-
ML
RS SH
R-
1- W
SNK-3
SNK-4
SNK-6
SNK-7
TNK-1
TNK-2
TNK-3
URN-1-M3
WC-1-M3
WC-1-W2
WU-08 WU-09
WU-12WU-13
CNTR-11
AHU-11 CNTR-12
AHU-12 CNTR-13
AHU-13
AHU-16
CNTR-16
CNTR-5
AHU-5
CNTR-14
AHU-14
B C
D E
F
EGD-12
EGD-15
EGD-16
LDR-1
OD-14
(IN HD)
(IN HD)
EGD-13
EGD-14
FD-5
FD-6
OD-15
OD-12
MCC
EL
FACU FACU
CP
CP-188
OHMIC-173
PNL-151MTS-150
PNL-149
PNL-143
FA-135FA-134
EL-50
PNL-124 XFMR-125
PNL-7060
PNL-7059
XFMR-7058
PNL-7056 XFMR-7057
XFMR-7044
PNL-7045
XFMR-68
PNL-67
PNL-7042
PNL-7043
PNL-105PNL-104PNL-103PNL-102PNL-101
SWG-118 XFMR-7009
SWS-7008
PNL-119
PNL-120
SWG-121
PNL-122
XFMR-7037 XFMR-49
PNL-48
XFMR-47XFMR-45
PNL-44
PNL-7036 XFMR-7035
MCC-46
PNL-43PNL-42PNL-41
SWG-40
PNL-39XFMR-38PNL-37PNL-36XFMR-35
PNL-32
XFMR-30XFMR-27XFMR-26
PNL-29 PNL-31PNL-25 PNL-28
SWG-66
B C
D E
F
UP
RAMP
SI
NK
BL
OC
KE
D
DO
OR
6" P
AD
MA
TE
RI
AL
R
OO
M
CO
MM
R
OO
M
POST DOCK
AVIONICS
POST DOCK
MEETING ROOMCO
MM
R
OO
M
BR
EA
K
RO
OM
OF
FI
CE
BA
CK
SH
OP
OFFICE
SE
RV
IC
IN
G
SE
CT
IO
N
B1-B MIC
EF-30
PKG-1
CU-19
AHU-19
PSFS-1
SNK-1
WU-03
26 27 28 29
EGD-1
OD-2
EGD-26
(IN HD)
OD-1
LDR-7
FACU FACU
CP
CP
CP-196
CP-197
MTS-145PNL-144 XFMR-90PNL-7055
XFMR-7051PNL-7052
PNL-8
XFMR-9
XFMR-7XFMR-6
PNL-5
XFMR-2FA-3 PNL-4FA-1
SWS-7013SWS-7012
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
CONCEPT
W W
YK
RE
PA
IR
F
AC
ILI
TY
H
VA
C
CO
NT
RO
L S
YS
TE
M, B
XX
X TE
PA
-C
SA
G
S
SE
XT
O
N
M-102
K
FR
EE
M
AN
J W
H
EE
LE
R
En gr
\D es ig n\ s\
\2
9\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
PA
RT
IA
L
SE
CO
ND
F
LO
OR
ME
CH
AN
IC
AL
H
VA
C
LA
YO
UT
04 05
GENERAL NOTES
1. THE DRAWING WAS PREPARED FROM EXISTING DRAWINGS AND LIMITED ACCESS
FOR FIELD OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS FOR ACCURACY.
M-102
PARTIAL SECOND FLOOR MECHANICAL HVAC WEST LAYOUT
SCALE: 1/16" = 1'-0"
M-102
PARTIAL SECOND FLOOR MECHANICAL HVAC EAST LAYOUT
SCALE: 1/16" = 1'-0"
B2122 KEYPLAN
EGD-32
LDR-1A
AHU-24
DSFD-26
DSVAV-5-06
AHU-7
CNTR-7
AHU-6
CNTR-6
DSVAV-5-05
DSVAV-5-04
DSVAV-5-03 DSVAV-5-02 DSVAV-5-01
DSVAV-5-07
DSVAV-5-08
DSVAV-5-09
DSVAV-5-10
DSVAV-5-11
DSVAV-5-12
DSVAV-5-13
DSVAV-5-15
DSFD-25
DSVAV-5-14
DSFD-34
DSFD-35
CNTR-24
PNL-58
PNL-54
PNL-55
XFMR-53
PNL-52
PNL-51
PNL-56
PNL-57
XFMR-73 XFMR-74
PNL-75
XFMR-76
PNL-77
PNL-78
PNL-79
PNL-80
PNL-85
PNL-86
PNL-81
PNL-87
25'-0"
25'-0"
25'-0"
457'-4"
25'-0"
SHELVES/DOORS/LOCKS
C
AB
IN
ET
S/ D
O O
R S/
LO
C
KS
CABINETS/DOORS/LOCKS
SH
EL
VE
S/
D O
O R
S/
LO
C
KS
SHELVES
SHELVES
SH
EL
VE
S
CABINETS/DOORS/LOCKS
EGD-33
EGD-34
LDR-7A
AHU-10
CNTR-10
AHU-8
CNTR-8
WU-11
PNL-61
PNL-89
PNL-88
PNL-62
PNL-63
25'-0"
25'-0"
25'-0"
25'-0"
457'-4"
B
C
D
E
F
RAMP UP RISE= 1'-0" PER 10'-0"
DOWN
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
CONCEPT
W W
YK
RE
PA
IR
F
AC
ILI
TY
H
VA
C
CO
NT
RO
L S
YS
TE
M, B
XX
X TE
PA
-C
SA
G
S
SE
XT
O
N
M-103
K
FR
EE
M
AN
J W
H
EE
LE
R
En gr
\D es ig n\ s\
\2
9\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
PA
RT
IA
L
RO
OF
LE
VE
L
ME
CH
AN
IC
AL
H
VA
C
LA
YO
UT
05 05
M-103
PARTIAL ROOF LEVEL MECHANICAL HVAC EAST LAYOUT
SCALE: 1/16" = 1'-0"
B2122 KEYPLAN
GENERAL NOTES
1. THE DRAWING WAS PREPARED FROM EXISTING DRAWINGS AND LIMITED ACCESS
FOR FIELD OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS FOR ACCURACY.
M-103
PARTIAL ROOF LEVEL MECHANICAL HVAC WEST LAYOUT
SCALE: 1/16" = 1'-0"
OHMIC-100a
OHMIC-100
CU-24
EF-16
CU-23
MAU-2.5MAU-2.4MAU-2.3 MAU-1
CNTR-M01
MAUFLT-1
MAU-19MAU-18 CT-1
PKG-4
CNTR-P4
B
C
D
E
F
CU-21
MAU-1.1 MAU-1.2 MAU-1.3
| Sheets and Views |
| 01-210129-G101-G101 |
| 02-210129-M100-M100 |
| 03-210129-M101-M101 |
| 04-210129-M102-M102 |
| 05-210129-M103-M103 |
File details come from the government source that posted it. Updated .