21-025-Golfview Heights of Westgate Water Main Replacement - Appendix C SUE Data 2.pdf

PDF 6 MB Posted

Attached to
Golfview Heights of Westgate Water Main Replacement
Solicitation number
IFB 720 WUD 21-025 1
Issued by
Palm Beach County, Florida

About this file

This is a Subsurface Utility Exploration (SUE) Test Hole Data report prepared for the Palm Beach County Water Utilities Department (PBCWUD) Project No. 21-025, the Golfview Heights of Westgate Water Main Replacement project in Florida. The document, dated February 5, 2026, was prepared by BFA under project manager Esteban Jimenez for client Keshavarz & Associates. The report documents six test holes excavated along Ohio Street to identify and map existing subsurface utilities prior to water main replacement work. The exploration identified multiple utility lines including fiber optic cables, water lines, telephone cables, buried electric lines, and communication lines. Test holes were marked with physical markers such as PK nails, hub and tack, chisels, steel pins, or spikes positioned at the crown or edge of each utility found. All utilities were found in good condition, running in an east-west direction across the project corridor.

The test hole data provides specific technical information for each utility location, including depth measurements, material composition, diameter sizes, elevation data referenced to NAVD 1988, and geographic coordinates (Northing and Easting). Water line depths range from 2.17 feet to 2.63 feet below surface, while fiber optic and communication cables vary from 2.06 feet to 3.89 feet depth. All utilities were discovered in grass and dirt areas adjacent to concrete and paver driveways. Survey pin elevations and cover-to-utility measurements are documented for each test hole location, with reference to nearby landmarks such as corner driveway edges, wood power poles, and chain-link fences. This comprehensive SUE data serves as critical design and construction documentation for the water main replacement project, enabling contractors to avoid conflicts with existing utilities during excavation and installation work.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PBCWUD No. 21-025 Appendix "C" - SUE TH Data

PAGE Appx. "C"-45

PAGE Appx. "C"-46

PAGE Appx. "C"-47

PBCWUD No. 21-025 Appendix "C" - SUE TH Data PAGE Appx. "C"-48

PAGE Appx. "C"-49

PAGE Appx. "C"-50

PAGE Appx. "C"-51

PAGE Appx. "C"-52

PAGE Appx. "C"-53

PAGE Appx. "C"-54

PAGE Appx. "C"-55

PAGE Appx. "C"-56

PAGE Appx. "C"-57

PAGE Appx. "C"-58

PAGE Appx. "C"-59

PAGE Appx. "C"-60

PAGE Appx. "C"-61

PAGE Appx. "C"-62

PAGE Appx. "C"-63

PAGE Appx. "C"-64

PAGE Appx. "C"-65

PAGE Appx. "C"-66

PAGE Appx. "C"-67

NOTE:

LEGEND H/T

PK

X

DBC

UTILITY COMPANIES WATER

TELEPHONE

TH# TYPE OF UTILITY SIZE & MATERIAL QTY. CONDITION

UTILITY

DIRECTION

SURVEY

PIN ELEV

COVER

TOP OF

UTIL ELEV

NORTHING EASTING SHEET TEST HOLE MARKER / NOTES

1 FIBER 1 1/4" DBC 1 Good E/W 11.98 3.89 8.09 850512.0 954330.8 C-75 H/T 2 WATER 2" WATER 1 Good E/W 11.71 2.17 9.54 850508.6 954454.6 C-75 H/T 3 TELEPHONE 3/4" DBC 1 Good E/W 14.04 2.06 11.98 850496.6 954772.3 C-76 H/T 4 FIBER 2" GRAY PVC 1 Good E/W 13.54 2.50 11.04 850489.2 954982.4 C-76 H/T 5 TELEPHONE 2" GRAY PVC 1 Good E/W 13.67 2.63 11.04 850488.1 954982.7 C-76 H/T 6 FIBER 3/4" DBC 1 Good E/W 12.62 3.35 9.27 850482.8 955171.2 C-77 H/T

TEST HOLE # 2 WATER

TEST HOLE INVENTORY

PROJECT: Golfview Heights of Westgate Water Main Replacement

CLIENT: KESHAVARZ & ASSOCIATES

BFA PROJECT MANAGER: ESTEBAN JIMENEZ

PROJECT NO.: WUD 21-025

BFA DATE: 2/5/2026

* SPECIFIC TEST HOLE NOTES FOLLOWING INVENTORY

INDIVIDUAL TEST HOLE MARKERS INCLUDE: PK NAIL, HUB & TACK, CHIS "X", STEEL PIN OR SPIKE.

THESE ARE SET OVER THE CROWN OR EDGE OF THE UTILITY FOUND. (SEE COLUMN LABELED TEST HOLE MARKER OR NOTES.)

TEST HOLE NOTES

NOTE: FOUND (1) 2" WATER LINE TEE PVC, TC=2.17

HUB & TACK TEST HOLE MARKER

PK NAIL TEST HOLE MARKER

CHIS "X" TEST HOLES MARKER

DIRECT BURIED CABLE

PALM BEACH COUNTY

AT&T

HPatty Typewritten Text

APPENDIX "C" - SUBSURFACE UTILITY EXPLORATION TEST HOLE DATA - OHIO STREET

FIBER OPTIC

HUB

3.89'

1-1/4"

FOUND (1) 1-4" DIRECT BURIED CABLE

FIBER OPTIC LINE

T.C. -3.89'

K&A CONSTRUCTION PLAN SHEET: C-75

CORNER OF CONCRETE DRIVEWAY AT EDGE OF PAVEMENT: 2.55'

FACE OF WOOD POWER POLE: 13.10'

ANGLE BREAK IN CONCRETE DRIVEWAY: 5.55'

8.09'

NAVD 1988

954330.8'

850512.0'

1-1/4" FIBER OPTIC CABLE

2-5-26

N/A

GRASS/DIRT

11.98'

8.09'

N/A

N/A

N/A

N/A

021606172

WUD 21-025 Golfview Heights at Westgate

OHIO STREET

RG, HW, DW, CB, AR

RON GASKILL

179 44

N/A

WATER LINE

2.17'

2"

FOUND (1) 2" PVC WATER LINE TEE

T.C. -2.17'

K&A CONSTRUCTION PLAN SHEET: C-75

CORNER OF CONCRETE DRIVEWAY AT EDGE OF PAVEMENT: 21.5'

FACE OF WOOD POWER POLE: 4.70'

9.54'

NAVD 1988

954454.6'

850508.6'

2" WATER LINE

2-5-26

N/A

GRASS/DIRT

11.71'

9.54'

N/A

N/A

N/A

N/A

021606172

WUD 21-025 Golfview Heights at Westgate

OHIO STREET

RG, HW, DW, CB, AR

RON GASKILL

179 42

CORNER OF PAVER DRIVEWAY AT EDGE OF PAVEMENT: 1.50'

TELEPHONE

2.06'

3/4"

FOUND 3/4" DIRECT BURIED CABLE

T.C. -2.06'

K&A CONSTRUCTION PLAN SHEET: C-76

CORNER OF CONCRETE DRIVEWAY AT EDGE OF PAVEMENT: 9.9'

FACE OF WOOD POWER POLE: 18.60'

11.98'

NAVD 1988

954772.3'

850496.6'

3/4" DIRECT BURIED CABLE

2-5-26

N/A

GRASS/DIRT

14.04'

11.98'

N/A

N/A

N/A

N/A

021606172

WUD 21-025 Golfview Heights at Westgate

OHIO STREET

RG, HW, DW, CB, AR

RON GASKILL

179 43

ANGLE BREAK IN CONCRETE DRIVEWAY:12.95'

FIBER OPTIC

2.50'

2"

FOUND (1) 2" GRAY PVC BURIED ELECTRIC

T.C. -2.50'

K&A CONSTRUCTION PLAN SHEET: C-76

CORNER OF CONCRETE DRIVEWAY: 8.55'

11.04'

NAVD 1988

954982.4

850489.2'

2" BURIED ELECTRIC

2-5-26

N/A

GRASS/DIRT

13.54'

11.04'

N/A

N/A

N/A

N/A

021606172

WUD 21-025 Golfview Heights at Westgate

OHIO STREET

RG, HW, DW, CB, AR

RON GASKILL

179 42

N/A

ANGLE BREAK IN CONCRETE DRIVEWAY: 9.25'

CORNER OF CONCRETE DRIVEWAY: 21.25'

UNKNOWN

2.63'

2"

FOUND (1) 2" GRAY PVC COMMUNICATION LINE

T.C. -2.63'

K&A CONSTRUCTION PLAN SHEET: C-76

CORNER OF CONCRETE DRIVEWAY: 9.55'

11.04'

NAVD 1988

954982.7'

850488.1'

2" COMMUNICATION

2-5-26

N/A

GRASS/DIRT

13.67'

11.04'

N/A

N/A

N/A

N/A

021606172

WUD 21-025 Golfview Heights at Westgate

OHIO STREET

RG, HW, DW, CB, AR

RON GASKILL

179 42

N/A

ANGLE BREAK IN CONCRETE DRIVEWAY: 9.45'

CORNER OF CONCRETE DRIVEWAY: 21.2'

FIBER OPTIC CABLE

3.35''

3/4"

FOUND (1) 3/4" DIRECT BURIED CABLEFIBER OPTIC LINE

T.C. -3.35'

K&A CONSTRUCTION PLAN SHEET: C-77

CORNER OF 3' CHAIN LINKG FENCE: 9.00'

9.27'

NAVD 1988

955171.2'

850482.8'

3/4" FIBER OPTIC CABLE

2-5-26

N/A

GRASS/DIRT

12.62'

9.27'

N/A

N/A

N/A

N/A

021606172

WUD 21-025 Golfview Heights at Westgate

OHIO STREET

RG, HW, DW, CB, AR

RON GASKILL

179 42

N/A

EDGE OF PAVEMENT: 4.55'

WOOD POWER POLE: 17.15'

File details come from the government source that posted it. Updated .