FY26 Boiler Inspections (Bid Schedule)_amended.xlsx

XLSX spreadsheet 27 KB Posted

Attached to
FY26 Boiler Inspections
Solicitation number
2026-PZI-1696
Issued by

About this file

This is a Bid Schedule (pricing template) for FY26 Boiler Inspections at Hanscom Air Force Base, Massachusetts. The schedule outlines Contract Line Items (CLINs) for a one-year base period (September 18, 2026 to September 17, 2027) plus four one-year option periods extending through September 17, 2031. The contractor shall provide inspection and testing services for four boiler units, one Heat Recovery Steam Generator (HRSG), and associated systems including condensate receiver tanks, compressors, compressed air tanks, deaerator tanks, pumps, economizers, fans, fuel train components, turbines, and safety valves.

The base year and option years include recurring CLINs for biannual Type "A" External/Internal Inspections and Type "C" External/Operational Inspections of boilers #1 and #2 (CLIN 0001/1001/2001/3001/4001); biannual inspections of boilers #3 and #4 (CLIN 0002/1002/2002/3002/4002); annual testing of 13 safety valves (CLIN 0003/1003/2003/3003/4003); and annual inspection of the HRSG (CLIN 0004/1004/2004/3004/4004). Option Year 1 includes an additional CLIN 1005 for a Deaerator Condition Assessment for all four boilers occurring every five years beginning in Option Year 1. All unit costs and totals are shown as $0.00 in this template, indicating pricing shall be provided by offerors. Questions were due August 26, 2026, with answers provided by August 28, 2026, and offers due September 2, 2026 at 11:00 AM EST. A mandatory site visit was scheduled for August 25, 2026 from 9:00-11:00 AM at Hanscom AFB Visitor Center.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Base Year

CONTRACT LINE
ITEM NO. (CLIN)SUPPLIES/SERVICEQTYUNITCOSTTOTAL
NON-PERSONAL SERVICES:
0001Inspection of boilers #1 and #2 and all assocciated elements to include a Type "A" External/Internal Inspection and Type "C" External/Operational inspections Biannually2EA$0.00
0002Inspection of boilers #3 and #4 and all associated element to include a Type "A" External/Internal Inspection and Type "C" External/Operational inspections Biannually2EA$0.00
0003Test Safety Valves Annually13EA$0.00
0004Inspection of Heat Recovery Steam Generator and all assocciated elements Annually1EA$0.00
September 18 2026 to September 17 2027 TOTAL CLINs 0001 through 0004$0.00

Option YR 1

CONTRACT LINE
ITEM NO. (CLIN)SUPPLIES/SERVICEQTYUNITCOSTTOTAL
NON-PERSONAL SERVICES:
1001Inspection of boilers #1 and #2 and all assocciated elements to include a Type "A" External/Internal Inspection and Type "C" External/Operational inspections Biannually2EA$0.00
1002Inspection of boilers #3 and #4 and all associated element to include a Type "A" External/Internal Inspection and Type "C" External/Operational inspections Biannually2EA$0.00
1003Test Safety Valves Annually13EA$0.00
1004Inspection of Heat Recovery Steam Generator and all assocciated elements Annually1EA$0.00
1005Dearator Condition Assessment for #1 Boiler, #2 Boiler, #3 Boiler, and #4 Boiler Every 5th year beginning in Option Year 11EA$0.00
September 18 2027 to September 17 2028 TOTAL CLINs 1001 through 1005$0.00

Option YR 2

CONTRACT LINE
ITEM NO. (CLIN)SUPPLIES/SERVICEQTYUNITCOSTTOTAL
NON-PERSONAL SERVICES:
2001Inspection of boilers #1 and #2 and all assocciated elements to include a Type "A" External/Internal Inspection and Type "C" External/Operational inspections Biannually2EA$0.00
2002Inspection of boilers #3 and #4 and all associated element to include a Type "A" External/Internal Inspection and Type "C" External/Operational inspections Biannually2EA$0.00
2003Test Safety Valves Annually13EA$0.00
2004Inspection of Heat Recovery Steam Generator and all assocciated elements Annually1EA$0.00
September 18 2028 to September 17 2029 TOTAL CLINs 2001 through 2004$0.00

Option YR 3

CONTRACT LINE
ITEM NO. (CLIN)SUPPLIES/SERVICEQTYUNITCOSTTOTAL
NON-PERSONAL SERVICES:
3001Inspection of boilers #1 and #2 and all assocciated elements to include a Type "A" External/Internal Inspection and Type "C" External/Operational inspections Biannually2EA$0.00
3002Inspection of boilers #3 and #4 and all associated element to include a Type "A" External/Internal Inspection and Type "C" External/Operational inspections Biannually2EA$0.00
3003Test Safety Valves Annually13EA$0.00
3004Inspection of Heat Recovery Steam Generator and all assocciated elements Annually1EA$0.00
September 18 2029 to September 17 2030 TOTAL CLINs 3001 through 3004$0.00

Option YR 4

CONTRACT LINE
ITEM NO. (CLIN)SUPPLIES/SERVICEQTYUNITCOSTTOTAL
NON-PERSONAL SERVICES:
4001Inspection of boilers #1 and #2 and all assocciated elements to include a Type "A" External/Internal Inspection and Type "C" External/Operational inspections Biannually2EA$0.00
4002Inspection of boilers #3 and #4 and all associated element to include a Type "A" External/Internal Inspection and Type "C" External/Operational inspections Biannually2EA$0.00
4003Test Safety Valves Annually13EA$0.00
4004Inspection of Heat Recovery Steam Generator and all assocciated elements Annually1EA$0.00
September 18 2030 to September 17 2031 TOTAL CLINs 4001 through 4004$0.00