2026.10.07 SUNY Maritime Baylis Signage Bid Set-rev.pdf

PDF 8 MB Posted

Attached to
Exterior Facade Signage Installation at Baylis Hall
Solicitation number
2140288
Issued by
Bronx County, New York

About this file

This is an architectural bid set for exterior facade signage installation at Baylis Hall, State University of New York Maritime College, located at 6 Pennyfield Avenue, Bronx, New York. The project involves the design and installation of an externally illuminated architectural "M" logo sign mounted to the north exterior facade of Baylis Hall. The scope of work requires comprehensive single-source design-build services including professional New York State licensed structural and electrical engineering, fabrication, installation, and all associated labor and materials. The sign specifications include a structural aluminum channel letter with LED face-lit illumination utilizing Panaflex fabric face with UV fade resistance, finished with white aluminum sides. The LED driver and accessories are to be located in the elevator machine room, with power sourced from spare circuits in the elevator room circuit breaker panel. The bid set, issued for bid on October 7, 2026, comprises four drawing sheets: title sheet (T-001), general notes and site map (A-001), existing plans (A-100), and exterior elevations (A-300). All work must comply with New York State Building Code and applicable federal, state, and municipal regulations. The contractor must submit signed and sealed shop drawings prepared by New York State licensed engineers prior to installation and shall guarantee the entire installation for one year.

Bidders must demonstrate successful completion of at least four comparable contracts of similar size, scope, complexity, and nature within the past five years. This is a prevailing wage project subject to New York State Finance Law 139-j and -k regarding lobbying restrictions. Vendors must provide valid and current New York State Worker's Compensation and Disability insurance forms. Minority and Women Business Enterprise (MWBE) contracting goals are established at 11 percent for Minority Business Enterprise (MBE) and 19 percent for Women Business Enterprise (WBE). The bid set specifies that logo signage materials must conform to 3M Panagraphics standards using 3M Scotchcal gloss overlaminate 3660G and matte overlaminate 3658M per manufacturer specifications. Additional requirements include submission of installation and rigging plans, sidewalk bridge plans, and traffic control and coordination plans for owner approval prior to work commencement. The contractor is responsible for site protection, restoration of existing conditions, daily debris removal, and coordination with the building owner regarding all construction activities and utility shutdowns.

View the file

Other files

File Type Posted
7557-104 EEO Policy statement.doc DOC document
IFB - Exterior Facade Signage Installation at Baylis Hall (002).pdf PDF
7557-107.docx DOCX document
Addendum No. 1.pdf PDF
Updated SIF.pdf PDF
7557-108.doc DOC document
Gender-Based Violence and the Workplace Certification.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SUNY MARITIME

6 Pennyfield Avenue, Throggs Neck, NY 10465

Baylis Hall Signage

DRAWING NO.

T-001 2026.10.01

LLC AIA

and

Architects Landow

Landow

SCHEDULE OF DRAWINGS

T-001 TITLE SHEET

ARCHITECTURAL

A-001 GENERAL NOTES AND SITE MAP

A-100 EXISTING PLANS

A-300 EXTERIOR ELEVATIONS

www.landow-architects.com mail@landow-architects.com Phone 212.772.7074 New York, NY, 10017 228 East 45th Street, Suite 1210

2026.10.07 ISSUE FOR BID

Architect:

Mechanical/Electrical Engineers:

LLC AIA

www.landow-architects.com mail@landow-architects.com Phone 516.326.1111 New York, NY 10017 and

Architects Landow

Landow

228 East 45th Street, Suite 1210

6 PENNYFIELD AVENUE, BRONX, NY 10465

BAYLIS HALL SIGNAGE

SUNY

MARITIME

1N.T.S.NOTES

GENERAL NOTES DEMOLITION NOTES ABBREVIATIONS

AC.T. ACOUSTICAL CEILING TILE

AD AUTOMATIC DOOR

ADJ. ADJACENT ADJUST. ADJUSTABLE

A.F.F. ABOVE FINISHED FLOOR

APPROX. APPROXIMATE

A.P. ACCESS PANEL

ACOUST. ACOUSTICAL

ARCH. ARCHITECTURAL

BOTT. BOTTOM

B/O BOTTOM OF

BLDG. BUILDING

CAB. CABINET

CLG. CEILING

C.L./ CENTER LINE

C.T. CERAMIC TILE

CONC. CONCRETE

C.MU. CONCRETE MASONRY UNIT

COL. COLUMN

CLOS. CLOSET

C.G. CORNER GUARD

CONT. CONTINUOUS

CONST. CONSTRUCTION

DET. DETAIL

DIA. DIAMETER

DIM. DIMENSION

DWG. DRAWING

D.F. DRINKING FOUNTAIN

DN. DOWN

D. DEEP

EA. EACH

E.W.C. ELECTRICAL WATER COOLER

E.G. EDGE GUARD

ELEC. ELECTRIC(AL)

EL./ELEV. ELEVATION

EQ. EQUAL

EQUIP. EQUIPMENT

EXIST./EX. EXISTING

E.J. EXPANSION JOINT

F.E.C. FIRE EXTINGUISHER CABINET

F.F. FINISHED FLOOR

F.D. FLOOR DRAIN

FLR. FLOOR

FLUOR. FLUORESCENT

FR FIRE RESISTANT

GALV. GALVANIZED

GA. GAUGE

G.C. GENERAL CONTRACTOR

GR. GRADE

GWB GYPSUM WALL BOARD

H. HIGH

HC HANDICAPPED

H.M. HOLLOW METAL

HGT. HEIGHT

H.V.A.C. HEATING, VENTILATION AND AIR

CONDITIONING

INSUL. INSULATION

INCAND. INCANDESCENT

INT. INTERIOR

INV. INVERT

JT. JOINT

J.C. JANITORS CLOSET

KITCH./KIT KITCHEN

LAV. LAVATORY

LVR. LOUVER

L. LENGTH

MFR. MANUFACTURER

M.O. MASONRY OPENING

MAX. MAXIMUM

MECH. MECHANICAL

M/E/P MECHANICAL, ELECTRICAL, PLUMBING

M.E.R. MECHANICAL EQUIPMENT ROOM

MTL. METAL

MIN. MINIMUM

MISC. MISCELLANEOUS

MTD. MOUNTED

NOM. NOMINAL

N.I.C. NOT IN CONTRACT

N.T.S. NOT TO SCALE

NO. NUMBER

O.C. ON CENTER

OPNG. OPENING

OPP. OPPOSITE

O.A. OUTSIDE DIAMETER

O.H. OVERHEAD

PNL. PANEL

P.L. PLASTIC LAMINATE

P.C. PLUMBING CONTRACTOR

PLYWD. PLYWOOD

P.T. PRESSURE TREATED

Q.T. QUARRY TILE

RAD. RADIUS

REQ'D REQUIRED

RM. ROOM

SCHED. SCHEDULE

SECT. SECTION

SIM. SIMILAR

S.S. STAINLESS STEEL

SPEC. SPECIFICATION

SHT. SHEET

STD. STANDARD

S.T.C. SOUND TRANSMISSION CLASS

STOR. STORAGE

SUSP. SUSPENDED

TEL. TELEPHONE

T/O TOP OF

TYP. TYPICAL

U.L. UNDERWRITERS LABORATORY

U.O.N. UNLESS OTHERWISE NOTED

V.I.F. VERIFY IN FIELD

VEST. VESTIBULE

V.W.C. VINYL WALL COVERING

V.C.T. VINYL COMPOSITION TILE

W.C. WATER CLOSET

W.P. WATERPROOFING

W/ WITH

W/O WITHOUT

WD WOOD

W WIDE

LEGEND

AREA NUMBER

SECTION NUMBER

SHEET NUMBER

ELEVATION NUMBER

SHEET NUMBER

SECTION NUMBER

SHEET NUMBER

EXISTING CONSTRUCTION

CONSTRUCTION ABOVE

UNLESS OTHERWISE NOTED

DETAIL NUMBER

SHEET NUMBER

CEILING HEIGHTC.H. (9'-6")

A-1

A-1

A-1

A-1

EXISTING CONSTRUCTION TO BE DEMOLISHED

NOTE: ADDITIONAL LEGEND ITEMS

PARTICULAR TO A SPECIFIC

DRAWING ARE INDICATED DIRECTLY

ON INDIVIDUAL DRAWINGS

LOCATION PLAN

CR

OW

NI

NS

HI

EL

D

ST

RE

ET

M

CG

OW

AN

S

TR

EE

T

ERBEN AVENUE

FIELD PLACE

RE

ED

ER

S

TR

EE

T

SHEPARD AVENUE

SHEPARD AVENUE

SHEPARD AVENUE

PA

TT

ER

SO

N

ST

RE

ET

EAST RIVER

LONG ISLAND SOUND

1. ALL INFORMATION CONTAINED ON THESE DRAWINGS REGARDING EXISTING FACILITIES IS TAKEN FROM DRAWINGS FURNISHED BY THE OWNER, OR FROM ASSUMPTIONS MADE FROM OBSERVATIONS. CONTRACTOR IS REQUIRED TO CHECK AND VERIFY ALL INFORMATION IN THE FIELD BEFORE PROCEEDING WITH CONSTRUCTION. THEY SHALL NOTIFY THE ARCHITECT IN WRITING OF ANY DIFFERENCES BETWEEN WHAT IS SHOWN ON THESE DRAWINGS AND FOUND IN ACTUALITY THAT WILL MATERIALLY AFFECT THE PROJECT AND OBTAIN THE ARCHITECT'S WRITTEN APPROVAL BEFORE PROCEEDING.

2. THE WORK SHOWN ON THE ATTACHED DRAWINGS IS INTENDED TO INCLUDE ALL LABOR AND MATERIALS NECESSARY TO COMPLETE THE PROJECT IN ITS

ENTIRETY, WHETHER SHOWN, DESCRIBED, REASONABLY IMPLIED, REQUIRED, OR INFERRED.

3. CONTRACTOR SHALL VISIT THE SITE AND REVIEW EXISTING CONDITIONS PRIOR TO SUBMITTING THEIR BID.

4. ACCESS TO ALL AREAS, CONSTRUCTION OPERATIONS AND UTILITY SHUTDOWNS SHALL BE COORDINATED WITH THE OWNER.

5. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AND DIMENSIONS. IF CONTRACTOR IS NOT ABLE TO ACHIEVE THE WORK INDICATED THEY ARE TO NOTIFY THE ARCHITECT IN WRITING AND RECEIVE THE ARCHITECTS WRITTEN APPROVAL PRIOR TO PROCEEDING WITH CONSTRUCTION.

6. ALL WORK SHALL COMPLY WITH THE BUILDING CODE OF THE STATE OF NEW YORK, THE CODES OF THE STATE OF NEW YORK, THE REGULATIONS OF THE NATIONAL BOARD OF FIRE UNDERWRITERS, AND ALL FEDERAL, STATE AND MUNICIPAL AUTHORITIES HAVING JURISDICTION OVER THE WORK.

7. ALL REFERENCES TO THE BUILDING CODE SHALL BE CONSTRUED TO MEAN THE BUILDING CODE OF THE STATE OF NEW YORK AND THE CODES OF THE

STATE OF NEW YORK.

8. ALL EXISTING CONSTRUCTION REQUIRING OPENING OR CUTTING TO ENABLE THE WORK OF ALL TRADES SHALL BE PATCHED AND FINISHED TO MATCH

EXISTING ON COMPLETION.

9. THE CONTRACTOR SHALL GUARANTEE THE ENTIRE INSTALLATION FOR A PERIOD OF ONE YEAR (EXCEPT WHEN A LONGER PERIOD IS OTHERWISE PROVIDED IN THE CONTRACT). THE CONTRACTOR SHALL REMOVE, REPLACE AND/OR REPAIR AT ITS OWN EXPENSE ANY DEFECTS IN WORKMANSHIP, MATERIALS, RATINGS, CAPACITIES OR CHARACTERISTICS OCCURRING IN OR TO THE WORK.

10. THE CONTRACTOR SHALL PROVIDE MATERIAL SAFETY DATA SHEETS FOR ALL MATERIALS PRIOR TO DELIVERING THE MATERIALS TO THE SITE.

11. DUCTS, PIPE AND CONDUITS PASSING THROUGH RATED CONSTRUCTION SHALL HAVE SPACES NOT EXCEEDING 1/2 INCH PACKED WITH MINERAL WOOL AND CLOSED OFF WITH CLOSE FITTING METAL ESCUTCHEONS. AGGREGATE NET AREA OF SUCH OPENING SHALL NOT EXCEED 25 SQUARE INCHES IN ANY 100 SQUARE FEET OF WALL OR FLOOR AREAS UNLESS PROTECTED BY RATED SELF-CLOSING DEVICES.

12. DO NOT DETERMINE DIMENSIONS BY SCALING DRAWINGS. ALL CONSTRUCTION DIMENSIONS AND DETAILS SHALL CONCUR WITH AND BE DETERMINED FROM THESE DRAWINGS. IF ANY REQUIRED DIMENSIONS ARE NOT INDICATED, DO NOT PROCEED WITHOUT REQUESTING SAME IN WRITING FROM

ARCHITECT.

13. LARGE SCALE DETAILS TAKE PRECEDENCE OVER SMALL. REPETITIVE FEATURES NOT COMPLETELY DESCRIBED AND/OR DETAILED SHALL BE CONSTRUCTED IN ACCORDANCE WITH CORRESPONDING FEATURES THAT ARE COMPLETELY DESCRIBED OR DETAILED.

14. ALL CONDITIONS LAYOUTS, ETC. LABELED AS 'TYPICAL' INDICATE THE WORK TO BE EXECUTED FOR ALL SIMILAR CONDITIONS.

15. THE OWNER RESERVES THE RIGHT TO DELIVER, PLACE AND INSTALL EQUIPMENT AND FURNISHINGS AS THE WORK PROGRESSES, AS LONG AS THERE IS

NO INTERFERENCE WITH THE WORK OF THE CONTRACTORS.

16. CONTRACTOR SHALL FURNISH AND INSTALL ANGLES, STRUTS, BRACKETS, TOGGLES, EYE BOLTS AND ALL ACCESSORIES REQUIRED TO PROPERLY

SUPPORT BRACE AND/OR REINFORCE ALL FINISHES, FRAMES, EQUIPMENT, ETC.

17. ALL MATERIALS, EQUIPMENT AND CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF ALL APPLICABLE CODES, AND REQUIREMENTS OF ALL

GOVERNING AND REGULATORY AUTHORITIES HAVING JURISDICTION.

18. THE ELECTRICAL WORK SHOWN ON THE ARCHITECTURAL DRAWINGS ARE TO INDICATE THE FUNCTIONAL USE OF THE SPACES.

19. ALL EXPOSED PIPING AND CONDUIT SHALL BE INSTALLED CLEANLY IN STRAIGHT LINES IN CONFIGURATION TO BE APPROVED BY THE ARCHITECT.

20. CONTRACTOR SHALL PROVIDE ALL ENGINEERING. SHOP DRAWINGS SIGNED AND SEALED BY NEW YORK STATE LICENSED ENGINEERS MUST BE

SUBMITTED PRIOR TO PERFORMING THE WORK.

21. THE CONTRACTOR IS RESPONSIBLE FOR RESTORING ALL EXISTING CONSTRUCTION AND THE SURROUNDING SITE WORK TO ITS ORIGINAL CONDITION AT THE COMPLETION OF THE INSTALLATION. ANY DEFICIENCIES IN THE EXISTING CONSTRUCTION OR SITE WORK MUST IMMEDIATELY BE BROUGHT TO THE

OWNER'S ATTENTION PRIOR TO PERFORMING THE WORK.

22. THE CONTRACTOR SHALL SUBMIT AN INSTALLATION AND RIGGING PLAN TO THE OWNER FOR APPROVAL PRIOR TO PERFORMING THE WORK.

23. THE CONTRACTOR SHALL SUBMIT A SIDEWALK BRIDGE PLAN AND A TRAFFIC CONTROL AND COORDINATION PLAN TO THE OWNER FOR APPROVAL PRIOR

TO PERFORMING THE WORK.

24. POWER FOR THE LIGHTING SYSTEM TO BE TAKEN FROM ANY OF THE FOUR SPARE CIRCUITS IN THE ELEVATOR ROOM CIRCUIT BREAKER PANEL LOCATED

IN THE ELEVATOR MECHANICAL ROOM ON THE BULK HEAD OF BAYLIS HALL ROOF.

25. LOGO SIGN TO BE 3M PANAGRAPHICS, 3M SCOTCHCAL GLOSS OVERLAMINATE 3660G AND 3M SCOTCHCAL MATTE OVERLAMINATE 3658M; FOLLOW

MANUFACTURER'S SPECIFICATIONS.

1. THE CONTRACTOR MUST INFORM THEMSELVES FULLY OF THE CONDITIONS RELATING TO THE CONSTRUCTION AND LABOR UNDER WHICH THE WORK WILL

BE PERFORMED.

2. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ANY PERMANENT OR TEMPORARY PARTS OF THE BUILDING, AND SURROUNDINGS CAUSED BY

THEIR OPERATIONS.

3. THE CONTRACTOR AND THEIR SUBCONTRACTORS ARE PUT ON NOTICE TO ASCERTAIN THE LOCATIONS OF, AND EXERCISE PRECAUTIONS IN AVOIDING DAMAGE TO, SERVICES RUNNING THROUGH AND ADJACENT TO THE BUILDING OR OTHER STRUCTURES. ANY DAMAGE TO SAID BUILDING OR OTHER STRUCTURES, THE PROJECT, OR ANY PERSON SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND THEY AGREE TO HOLD HARMLESS THE OWNER, ARCHITECT, ENGINEERS, AND THEIR AGENTS FROM ANY CLAIMS ARISING BY REASON THEREOF.

4. THE CONTRACTOR SHALL PROVIDE, ERECT AND MAINTAIN ANY AND ALL SAFEGUARDS, INCLUDING LIGHTS, BARRICADES, AND WARNING SIGNS AS NECESSARY TO INSURE THE SAFETY AND PROTECTION OF THE PUBLIC AND ALL WORKERS AS REQUIRED BY ALL GOVERNMENTAL AGENCIES AND CODES

HAVING JURISDICTION OVER THE PROJECT AND IN ACCORDANCE WITH GOOD SAFETY.

5. CONTRACTOR SHALL DEMOLISH, REMOVE FROM THE PREMISES, AND LEGALLY DISPOSE OF ALL CONSTRUCTION MATERIALS AND EQUIPMENT EITHER SPECIFICALLY DESIGNATED TO BE DEMOLISHED OR REMOVED, OR THAT INTERFERES WITH OR IS NOT PART OF THE FINISHED WORK AS DEPICTED BY THE

DRAWINGS AND SPECIFICATIONS, INCLUDING DEBRIS PILED ON SITE.

6. PRIOR TO DOING ANY DEMOLITION WORK, CONTRACTOR SHALL SAFELY AND SECURELY BRACE AND SUPPORT ALL CONSTRUCTION AFFECTED BY THE DEMOLITION WORK INCLUDING SHORING, TEMPORARY SUPPORTS, ETC. TO ASSURE THE STRUCTURAL STABILITY OF THE BUILDING OR OTHER

STRUCTURES.

7. PRIOR TO DOING ANY DEMOLITION WORK, CONTRACTOR SHALL DISCONNECT ANY ELECTRICAL CONSTRUCTION INTERFERING WITH OR CONNECTED TO THE WORK TO BE DEMOLISHED OR REMOVED. AT THE COMPLETION OF THE WORK, THEY SHALL RESTORE SERVICE TO ANY ELECTRICAL DEVICES TEMPORARILY DISCONNECTED, AND THEY SHALL SAFELY REMOVE WIRING, PIPING, AND DEVICES FOR EQUIPMENT THAT IS REMOVED, CAPPING OFF SERVICE IN A SAFE AND LEGAL MANNER. COORDINATE ALL SHUT DOWNS AND DISCONNECTIONS WITH OWNER BEFORE PERFORMING THE WORK.

8. THE CONTRACTOR SHALL PERFORM ALL DEMOLITION WORK SAFELY AND CAUTIOUSLY IN ORDER TO AVOID ACCIDENTS, INJURY, AND UNINTENDED

PROPERTY DAMAGE. ALL DEMOLITION WORK SHALL BE CAREFULLY PERFORMED BY HAND.

9. ALL DEMOLITION WORK SHALL BE PERFORMED DURING REGULAR WORKING HOURS ON WEEKDAYS AND IN ACCORDANCE WITH BUILDING'S RULES AND

REGULATIONS REGARDING CONSTRUCTION WORK. UON

10. ALL MATERIALS AND EQUIPMENT BROUGHT TO THE JOB SITE AND ALL MATERIALS AND EQUIPMENT REMOVED FROM THE JOB SITE MUST BE COORDINATED

WITH BUILDING OWNER. PROVIDE PROTECTION.

11. RETAIN AND PROTECT EXISTING STOREFRONT, PARTITIONS, DOORS, PLUMBING FIXTURES AND OTHER CONSTRUCTION OR EQUIPMENT SCHEDULED TO

REMAIN.

12. REMOVE AND OR RELOCATE AS REQUIRED OR INDICATED ON DWGS EXISTING PLUMBING, HEATING, AND ELECTRICAL LINES. PROVIDE MINIMUM INTERRUPTION OF SERVICES AND TEMPORARY SERVICES AS REQUIRED DURING RELOCATION OF UTILITY LINES.

13. REMOVE, MAKE SAFE, AND RELOCATE AS REQUIRED AND INDICATED ON DRAWINGS EXISTING ELECTRICAL CONDUIT, BX CABLE, ROMEX CABLE, JUNCTION BOXES, OUTLETS, SWITCHES, CIRCUIT BREAKER OR FUSE PANELS, DISTRIBUTION PANELS, AND OTHER ASSOCIATED ELECTRICAL WIRING OR FIXTURES

THAT ARE NOT TO BE REUSED.

14. REMOVE AND PROPERLY DISPOSE OF ALL DEMOLITION DEBRIS DAILY FROM SITE. AT THE COMPLETION OF DEMOLITION WORK, LEAVE ALL AREAS BROOM CLEAN. COORDINATE WITH BUILDING OWNER CONSTRUCTION DEBRIS, AND WASTE DUMPSTER STORAGE.

15. DEMOLITION SHALL INCLUDE ALL CONSTRUCTION AND FINISHES NECESSARY TO FACILITATE INSTALLATION OF NEW WORK CONTEMPLATED BY

CONSTRUCTION DOCUMENTS.

BAYLIS HALL

LOCATION OF SIGN

A-001

GENERAL NOTES AND

SITE MAP

09.DD.2026

296526

Landow and Landow Architects LLP AIA

PROJECT LOCATION:

DRAWING TITLE

DRAWING NO.

PROJECT NO.:

PROJECT DATE:

.00

NYC DOB NUMBER

DATE NO.

REVISIONS

C

It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter an item in any way.

REQUIRED INFORMATION WHEN ALTERING SEALED DOCUMENTS

Both Section 69.5(b) of the regulations and Section 7209(2) of the Education law require that, in the event an item bearing the seal of an architect or engineer is altered, the altering architect or engineer must affix his/her own seal to the document. In addition, the architect or engineer who has altered the document is required to (a) include a notation that the document has been "altered by" the architect or engineer; (b) sign and date the altered document; and (c) provide a specific description of the alteration. to ensure compliance with both Section 69.5(b) and Section 7209(2), the design professional must include the following on all altered documents which had been previously sealed:

Altered By:

Date:

Signature:

Description of Alteration:

6 PENNYFIELD AVE.

BRONX, NY 10465

2026.10.01

2026.10.07ISSUE FOR BID

LLC AIA

www.landow-architects.com mail@landow-architects.com Phone 516.326.1111 New York, NY 10017 and

Architects Landow

Landow

228 East 45th Street, Suite 1210

6 PENNYFIELD AVENUE, BRONX, NY 10465

BAYLIS HALL SIGNAGE

SUNY

MARITIME

A

B F

J K L M N P Q R S T D H

G

A B F J

9 9

EC

16A

14A

EXISTING ROOF PLAN 1/8" = 1'-0" 1

J K

16A

14A

21/4" = 1'-0"ENLARGED ELEVATOR MACHINE ROOM PLAN

J K

16A

14A

A-100

EXISTING PLANS

09.DD.2026

296526

Landow and Landow Architects LLP AIA

PROJECT LOCATION:

DRAWING TITLE

DRAWING NO.

PROJECT NO.:

PROJECT DATE:

.00

NYC DOB NUMBER

DATE NO.

REVISIONS

C

It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter an item in any way.

REQUIRED INFORMATION WHEN ALTERING SEALED DOCUMENTS

Both Section 69.5(b) of the regulations and Section 7209(2) of the Education law require that, in the event an item bearing the seal of an architect or engineer is altered, the altering architect or engineer must affix his/her own seal to the document. In addition, the architect or engineer who has altered the document is required to (a) include a notation that the document has been "altered by" the architect or engineer; (b) sign and date the altered document; and (c) provide a specific description of the alteration. to ensure compliance with both Section 69.5(b) and Section 7209(2), the design professional must include the following on all altered documents which had been previously sealed:

Altered By:

Date:

Signature:

Description of Alteration:

6 PENNYFIELD AVE.

BRONX, NY 10465

2026.10.01

2026.10.07ISSUE FOR BID

AutoCAD SHX Text A-100

AutoCAD SHX Text

AutoCAD SHX Text 175'-8"

AutoCAD SHX Text 141'-11"

AutoCAD SHX Text A-300

AutoCAD SHX Text

AutoCAD SHX Text A-300

AutoCAD SHX Text

AutoCAD SHX Text 24'-8"

AutoCAD SHX Text 24'-8"

AutoCAD SHX Text V.I.F.

AutoCAD SHX Text 28'-5"

AutoCAD SHX Text 26'-8"

AutoCAD SHX Text

EQ

AutoCAD SHX Text

EQ

AutoCAD SHX Text ±1'-11"

AutoCAD SHX Text 20'-10"

AutoCAD SHX Text

EQ

AutoCAD SHX Text

EQ

AutoCAD SHX Text ±1'-11"

AutoCAD SHX Text A-300

AutoCAD SHX Text

AutoCAD SHX Text LOGO SIGN, ANCHOR TO STRUCTURE. STRUCTURAL ALUMINUM CHANNEL LETTER WITH LED FACE LIT ILLUMINATION WITH PANAFLEX FABRIC FACE W/ UV FADE RESISTANCE.

AutoCAD SHX Text ALL STRUCTURAL AND ELECTRICAL ENGINEERING TO BE PROVIDED BY VENDOR'S NEW YORK STATE LICENSED ENGINEERS WHO SHALL SUBMIT SIGNED AND SEALED DRAWINGS TO THE OWNER PRIOR TO INSTALLATION.

LLC AIA

www.landow-architects.com mail@landow-architects.com Phone 516.326.1111 New York, NY 10017 and

Architects Landow

Landow

228 East 45th Street, Suite 1210

6 PENNYFIELD AVENUE, BRONX, NY 10465

BAYLIS HALL SIGNAGE

SUNY

MARITIME

11/8" = 1'-0"NORTH ELEVATION

MACHINE RM. FLOOR

EL. 86.31'

MACHINE RM. ROOF

EL. 95.64'

ROOF

EL. 77.34'

PARAPET

EL. 80.34'

ENLARGED PARTIAL NORTH ELEVATION 1/2" = 1'-0" 2 31/2" = 1'-0"SECTION

K J

MACHINE RM. FLOOR

EL. 86.31'

MACHINE RM. ROOF

EL. 95.64'

ROOF

EL. 77.34'

PARAPET

EL. 80.34'

16A16

A-300

EXTERIOR ELEVATIONS

09.DD.2026

296526

Landow and Landow Architects LLP AIA

PROJECT LOCATION:

DRAWING TITLE

DRAWING NO.

PROJECT NO.:

PROJECT DATE:

.00

NYC DOB NUMBER

DATE NO.

REVISIONS

C

It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter an item in any way.

REQUIRED INFORMATION WHEN ALTERING SEALED DOCUMENTS

Both Section 69.5(b) of the regulations and Section 7209(2) of the Education law require that, in the event an item bearing the seal of an architect or engineer is altered, the altering architect or engineer must affix his/her own seal to the document. In addition, the architect or engineer who has altered the document is required to (a) include a notation that the document has been "altered by" the architect or engineer; (b) sign and date the altered document; and (c) provide a specific description of the alteration. to ensure compliance with both Section 69.5(b) and Section 7209(2), the design professional must include the following on all altered documents which had been previously sealed:

Altered By:

Date:

Signature:

Description of Alteration:

6 PENNYFIELD AVE.

BRONX, NY 10465

2026.10.01

2026.10.07ISSUE FOR BID

AutoCAD SHX Text A-300

AutoCAD SHX Text

AutoCAD SHX Text A-300

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING BRICK JOINT AND WEEP HOLES

AutoCAD SHX Text

EQ

AutoCAD SHX Text

EQ

AutoCAD SHX Text ±1'-11"

AutoCAD SHX Text 20'-10"

AutoCAD SHX Text

EQ

AutoCAD SHX Text

EQ

AutoCAD SHX Text ±1'-11"

AutoCAD SHX Text ±13'-5"

AutoCAD SHX Text ±13'-5"

AutoCAD SHX Text

VERIFY W/SIGN MANUFACTURER

AutoCAD SHX Text 2'-7"

AutoCAD SHX Text 24'-8"

AutoCAD SHX Text 24'-8"

AutoCAD SHX Text V.I.F.

AutoCAD SHX Text

CARDINAL, SEE SPECIFICATION ON 1/A-300

AutoCAD SHX Text

NAVY, SEE SPECIFICATION ON 1/A-300

AutoCAD SHX Text

ELEVATOR SHAFT

AutoCAD SHX Text

MACHINE ROOM

AutoCAD SHX Text 8"

AutoCAD SHX Text

LOGO SIGN, ANCHOR TO STRUCTURE.

AutoCAD SHX Text PROVIDE SLEEVES WITH WATERPROOFING FOR LED POWER CONDUITS. LOCATE LED DRIVER AND ACCESSORIES IN ELEVATOR MACHINE ROOM.

AutoCAD SHX Text

INSTALL BACK OF SIGN TO ALLOW FOR PROPER FLASHING & WEEP FUNCTION.

AutoCAD SHX Text ALL STRUCTURAL AND ELECTRICAL ENGINEERING TO BE PROVIDED BY VENDOR'S NEW YORK STATE LICENSED ENGINEERS WHO SHALL SUBMIT SIGNED AND SEALED DRAWINGS TO THE OWNER PRIOR TO INSTALLATION.

AutoCAD SHX Text A-300

AutoCAD SHX Text

AutoCAD SHX Text

ALIGN

AutoCAD SHX Text 2'-7"

AutoCAD SHX Text

FACELIT LOGO SIGN WITH WHITE ALUMINUM SIDES

Sheets and Views
T-001 TITLE SHEET
A-001 GENERAL NOTES AND SITE MAP
General Notes and Site Map - V
A-100 EXISTING PLANS
Roof Plan - V
Elev Rm Plan - V
Elev Rm Plan - V(2)
A-300 EXTERIOR ELEVATIONS
North Elev - V
North Elev ENLG_SECTION - V

File details come from the government source that posted it. Updated .