This is an Architectural Permit Set for the Toledo High School Auditorium project prepared by GLAS Architects, LLC for the Lincoln County School District in Toledo, Oregon. The project encompasses a phased renovation and new construction program consisting of four packages: Package 1 (current application) involves remodeling the existing cafeteria and band room into a new band room, toilet rooms, and an elevator connecting all four floors of the existing building; Package 2 addresses site preparation for the new auditorium; Package 3 covers foundations and underground utilities; and Package 4 includes the building shell and interior buildout. The new auditorium will accommodate 299 fixed seats and include a lobby, green room/dressing rooms, and an elevated stage. The project site is located at 1800 N.E. Sturdevant Road, Toledo, Oregon 97391, on a 13.64-acre property zoned P-F (Public/Facilities). The building is classified as Risk Category III with Construction Type IIIB fully sprinklered for the renovation and Type VB for existing structures. Design compliance is based on the 2025 Oregon Structural Specialty Code, 2025 Oregon Fire Code, ICC A117.1-2017 accessibility standards, and the 2010 ADA Standards for Accessible Design.
The project design incorporates extensive structural, mechanical, electrical, plumbing, and fire safety systems with multiple deferred submittals requiring engineer-sealed documentation prior to construction. Structural design includes existing concrete shear walls, new reinforced concrete masonry walls, wood-framed components, and a seismic force-resisting system evaluated using ASCE 41-17 Linear Static Procedure with a building period of 0.22 seconds and design spectral response values of 0.941g and 1.412g for BSE-1N and BSE-2N respectively. The mechanical/electrical/plumbing design-build contractor is to be determined, with low voltage systems to be handled by the owner. Special inspections and testing are required throughout construction in accordance with OSSC Section 1705, including inspections of fabrication, concrete placement, steel erection, welding, masonry work, and soil conditions. The project document package includes comprehensive life safety plans, code narratives, accessibility signage standards, and detailed structural notes addressing concrete reinforcement, masonry, lumber specifications, fastening systems, and corrosion protection requirements for all structural steel components.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| TOHS Elevator RFP.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLIENT
Lincoln County School District
Toledo Junior / Senior High School
1800 N.E. Sturdevant Rd. Toledo, Oregon 97391
541 336 5104
ARCHITECT OF RECORD
GLAS Architects, LLC
Chris Walkup
44 W Broadway, Ste 430, Eugene, OR 97401
541 686 2014
STRUCTURAL
KPFF
Joshua Richards
111 SW Fifth Ave, Ste 2600 Portland, OR 97204
503 227 7980
MECHANICAL / ELECTRICAL / PLUMBING
DESIGN BUILD CONTRACTOR, TBD
LOW VOLTAGE
BY OWNER
DESIGN ARCHITECT
Hacker
Nick Hodges
555 SE MLK Ave, Ste 501 Portland, OR 97214
503 337 1254
CONCEPTUAL RENDERING
N E S
T U
R D
E V
A N
T P
I
NE STURDEVANT RD
N E H
W Y
VICINITY MAP
N
TOLEDO HIGH SCHOOL AUDITORIUM
06/01/26
SITE
LINCOLN COUNTY SCHOOL DISTRICT
PACKAGE #1 - CAFETERIA AND BAND ROOM REMODEL AND ADDITION
' X ' ISSUED
' X (ADD #) ' ISSUED/REVISED AS A PART OF AN ADDENDUM
' X (PR #) ' ISSUED/REVISED AS A PART OF A PROPOSAL REQUEST
' X (ASI #) ' ISSUED/REVISED AS A PART OF AN ASI
' REF ' ISSUED AS A REFERENCE ONLY DOCUMENT
' REF (PR #) ' REFERENCE ONLY DOCUMENT ISSUED/REVISED AS A PART OF A PROPOSAL REQUEST
' ' NOT A PART OF ISSUED SET
' DELETE ' DELETED FROM PROJECT
ISSUANCE LOG LEGEND
ARCHITECTS
CONSULTANT
STAMP
REVISION NO. DATE
KEY PLAN - (NTS)
SHEET NUMBER
DRAWING TITLE
SCALE
DATE
PROJECT NUMBER
ISSUANCE
TRUE
NORTH
PLAN
NORTH
NOT FOR
CONSTRUCTION
12" = 1'-0"
G-002
06/01/26
25035
TOLEDO HIGH
SCHOOL
AUDITORIUM
LINCOLN COUNTY SCHOOL DISTRICT
1800 N.E. STURDEVANT RD.
TOLEDO, OREGON 97391
SHEET INDEX
PACKAGE 1: RENOVATION
SHEET INDEX PACKAGE 1
SHEET
NO
SHEET NAME PKG -1 PKG -2 PKG -3 PKG -4
0_GENERAL
G-000.1 COVER SHEET X
G-002 SHEET INDEX X
G-011.1 CODE SITE PLAN X
G-111.1 CODE NARRATIVE X
G-131 LIFE SAFETY PLAN - BASEMENT X
G-132 LIFE SAFETY PLAN - LEVEL 01, 02 & 03 X
G-133 LIFE SAFETY PLAN - LEVEL 04 & 05 X
G-201 CODE SIGNAGE STANDARDS X
G-202 CODE SIGNAGE PLAN X
STRUCTURAL
S-001.1 DRAWING INDEX AND LIST OF ABBREVATIONS X
S-002.1 GENERAL STRUCTURAL NOTES X
S-003.1 GENERAL STRUCTURAL NOTES CONT. X
S-004.1 GENERAL STRUCTURAL NOTES CONT. X
S-005.1 SPECIAL INSPECTIONS AND TESTING X
S-006.1 SPECIAL INSPECTIONS AND TESTING CONT. X
S-132.1 FOUNDATION PLAN X
S-133.1 FLOOR FRAMING PLAN LEVELS 04 AND 05 X
S-136.1 ROOF FRAMING PLAN X
S-301.1 WALL ELEVATIONS X
S-501.1 TYPICAL CONCRETE DETAILS X
S-511.1 TYPICAL MASONRY DETAILS X
S-601.1 TYPICAL STEEL DETAILS X
S-701.1 TYPICAL WOOD DETAILS X
S-702.1 TYPICAL WOOD DETAILS X
S-703.1 TYPICAL WOOD DETAILS X
1_DEMO
DA-134.1 DEMO ENLARGED FLOOR PLAN - LEVEL 02 & 03 X
DA-136.1 DEMO WALL ELEVATIONS X
2_ARCHITECTURAL
A-011 ARCHITECTURAL SYMBOLS AND ABBREVIATIONS X
A-132.1 OVERALL FLOOR PLAN LEVEL 02 & 03 X
A-133.1 OVERALL FLOOR PLAN LEVEL 04 & 05 X
A-136.1 OVERALL ROOF PLAN X
A-144.1 ENLARGED FLOOR PLAN - RESTROOMS X
A-145.1 ENLARGED FLOOR PLAN - BAND ROOM X
A-146.1 ENLARGED FLOOR PLAN - ELEVATOR CORRIDORS X
A-154.1 ENLARGED RCP - RESTROOMS X
A-155.1 ENLARGED RCP - BAND ROOM X
A-156.1 ENLARGED RCP - ELEVATOR CORRIDORS X
A-213.1 EXTERIOR ELEVATIONS X
A-261 STANDARD MOUNTING DIMENSIONS X
A-269.1 INTERIOR ELEVATIONS X
A-270.1 INTERIOR ELEVATIONS X
A-271.1 INTERIOR ELEVATIONS X
A-311.1 BUILDING SECTIONS X
A-510 EXTERIOR ASSEMBLIES REF
A-601.1 DOOR & WINDOW SCHEDULE X
A-711.1 FINISH SCHEDULE X
ChrisWalkup
' 157.59'
.0
S86°18'E 362.0'
1100' M/L
N78°W 112'
N °W
N °E
.0
102.0'
EAST
(E) PARKING
(E) PARKING
(E) PARKING
(E) PARKING
(E) PARKING (E) PARKING
(E) STAIRS
(E) TRACK
(E) STAIRS
(E) TRANSFORMER
AREA OF WORK
ENTRANCE
ENTRANCE
N E
ST
U R
D E V
A N
T R
D
N E
S T
U R
D E
V A
N T
R D
N E
S T
U R
D E
V A
N T
R D
N E
ST
U
RD
EV
A N
T
PI
(E) FIRE HYDRANT
(E) LIGHT POLE
(E) COMPRESSORS
(E) SIGNAGE
ENTRANCE
BUILDING A (EXISTING)
BUILDING A (RENOVATION)
BUILDING C (FUTURE
PHASE)
BUILDING B (EXISTING)
BUILDING C (EXISTING)
(E
H
O U
R F
IR
E
W A
LL
(E) 2 HOUR FIRE WALL
2 HOUR FIRE WALL
(FUTURE PHASE)
GENERAL NOTES - SITE PLAN
A. REFERENCE CIVIL AND/OR LANDSCAPE DRAWINGS FOR
GRADING AND HORIZONTAL CONTROL DRAWINGS.
B. REF LANDSCAPE DRAWINGS FOR ALL SITE MATERIALS,
LAYOUT, AND ACCESS COMPLIANCE SITE/PATH OF
TRAVEL DRAWINGS.
C. REFERENCE A-011 FOR ABBREVIATIONS, SYMBOLS AND
GENERAL DIMENSIONING NOTES.
D. REF STRUCTURAL DRAWINGS FOR DIMENSIONS AND
ELEVATIONS OF STRUCTURAL SLAB AND WALL
ELEMENTS.
SITE LEGEND
RENOVATION
EXISTING BUILDING
PROPERTY LINE
TOPOGRAPHY LINES
(E) FIRE HYDRANT LOCATION
PATH OF EGRESS
(E) POWER POLE
ARCHITECTS
CONSULTANT
STAMP
REVISION NO. DATE
KEY PLAN - (NTS)
SHEET NUMBER
DRAWING TITLE
SCALE
DATE
PROJECT NUMBER
ISSUANCE
TRUE
NORTH
PLAN
NORTH
NOT FOR
CONSTRUCTION
As indicated
G-011.1
06/01/26
25035
TOLEDO HIGH
SCHOOL
AUDITORIUM
LINCOLN COUNTY SCHOOL DISTRICT
1800 N.E. STURDEVANT RD.
TOLEDO, OREGON 97391
CODE SITE PLAN
PACKAGE 1: RENOVATION
1" = 40'-0" G-011.1
1 Site Plan - Life Safety & Zoning Code - Renovation
PROJECT INFORMATION AND CODE ANALYSIS
PROJECT INFORMATION
SITE ADDRESS: 1800 NE STURDEVANT RD, TOLEDO, OR 97391
BLOCK NO.: CS 8737
STATE ID: R204720
MAP: 11-10-08-A0-02900-00
PROPERTY USE: 921: EXEMPT SCHOOL IMPROVED PROPERTY
ZONING: P-F
CLIMATE ZONE: 4C
LEGAL DESCRIPTION: TWNSHP 11, RNG 10, ACRES 13.64,
DV165-0041 & DV264-0241
RISK CATEGORY: III (PER TABLE 1604.5)
2025 OREGON STRUCTURAL SPECIALTY CODE (OSSC)
2025 OREGON FIRE CODE (OFC)
ICC A117.1-2017 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES, EXISTING
FACILITIES
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN (ADAS)
2025 OREGON ENERGY EFFICIENCY SPECIALTY CODE (OEESC)
2025 OREGON MECHANICAL SPECIALTY CODE (OMSC)
2023 OREGON ELECTRICAL SPECIALTY CODE (OESC)
2023 OREGON PLUMBING SPECIALTY CODE (OPSC)
SEPARATE PERMITS
• MECHANICAL, PLUMBING, ELECTRICAL
• FIRE ALARM SYSTEM
• FIRE PROTECTION SYSTEM INCLUDING ALL FIRE SPRINKLERS, STAND PIPE, AND
DOUBLE CHECK VALVE ASSEMBLY
DEFERRED SUBMITTALS
1. POST TENSIONED SLABS
2. STEEL STAIRS
3. PREFABRICATED TRUSSES
4. FLOOR JOISTS
5. WOOD TIE DOWN SYSTEMS
6. METAL WALL PANELS AND ATTACHMENTS
7. WINDOW, LOUVERS AND ATTACHMENTS (INCLUDING SKYLIGHT SYSTEMS)
8. FALL ARREST ANCHORS
9. SEISMIC AND SUPPORT OF ALL EQUIPMENT
10. TELECOM VOICE AND DATA SYSTEMS
11. EMERGENCY RESPONDER IN-BUILDING RADIO ENHANCEMENT- DISTRIBUTED
ANTENNA SYSTEM (DAS)
12. SECURITY SYSTEM
13.CODE SIGNAGE
OPTIONAL:
GUARDRAIL AND HANDRAILS (INCLUDING GLASS)
COLD FORM METAL FRAMING
LIGHT GAGE METAL FRAMING
CEILING SUSPENSION SYSTEMS
BUILDING MAINTENANCE SYSTEMS
THESE ITEMS ARE DEFERRED SUBMITTALS AND NOT INCLUDED IN THIS BUILDING
PERMIT. THE DRAWINGS AND CALCULATIONS FOR THESE ARE REQUIRED TO BE
STAMPED BY AN ENGINEER REGISTERED IN THE STATE IN WHICH THE PROJECT IS
CONSTRUCTED, AND APPROVED BY THE ENGINEER OF RECORD PRIOR TO
SUBMITTING TO THE AUTHORITY HAVING JURISDICTION (AHJ) OVER THE PROJECT.
OREGON FIRE CODE NOTES
ANY INSTALLATION DETAILS FOR FIRE AND LIFE SAFETY SYSTEMS INCLUDING FIRE
SPRINKLERS, FIRE ALARM SYSTEMS, BUILT-IN RADIO ENHANCEMENT SYSTEM (DAS),
AND STATIONARY GENERATORS ARE FOR REFERENCE ONLY WITH FINAL
INSTALLATION REQUIREMENTS TO BE DETERMINED DURING THE TRADE PLAN
REVIEW PROCESS AT THE FIRE MARSHALL'S OFFICE.
THE GENERAL CONTRACTOR SHALL SCHEDULE A FIRESTOPPING MEETING WITH THE
BUILDING INSPECTOR AND ALL SUBCONTRACTORS THAT WILL BE ABOUT INSTALLING
FIRESTOPPING MATERIALS. EACH CONTRACTOR WILL PROVIDE A LIST OF FIRESTOP
MATERIALS/ASSEMBLIES WHICH WILL BE USED., THE TYPE OF PENETRATIONS WHERE
EACH MATERIAL/ASSEMBLY WILL BE USED, AND THE LISTING AND APPROVAL
INFORMATION (I.E.. UL, ICC OR OTHER APPROVED REPORTING/LISTING NUMBERS).
THIS INFORMATION MUST BE SUBMITTED TO, AND APPROVED BY, THE BUILDING
INSPECTOR PRIOR TO ANY INSTALLATION.
AERIAL FIRE APPARATUS ROAD ACCESS
USE AND OCCUPANCY (CHAPTER 3)
SPECIAL REQUIREMENTS (CHAPTER 4)
N/A
BUILDING HEIGHTS & AREAS (CHAPTER 5)
BUILDING A
CONSTRUCTION TYPE TYPE IIIB, FULLY SPRINKLERED
OCCUPANCY: E
BASE ALLOWABLE HEIGHT 75'
(TABLE 504.3)
ALLOWABLE STORIES 3
(TABLE 504.4)
ALLOWABLE AREA 43,500
(TABLE 506.2)
FRONTAGE INCREASE FACTOR: 21% (TABLE 506.3.3)
ALLOWABLE AREA = 43,500 + (14,500 X .21) = 46,545 SF (PER FLOOR)
PROPOSED AREA = 41,358 SF (GROUND FLOOR)
PROPOSED AREA = 12,403 SF (SECOND FLOOR)
PROPOSED HEIGHT = 31'
PROPOSED FLOORS = 2
OCCUPANCY SEPARATIONS: NONSEPARATED PER 508.3
BUILDING B (EXISTING - NO PROPOSED CHANGES
CONSTRUCTION TYPE TYPE VB, FULLY SPRINKLERED
BUILDING C (FUTURE PHASE)
CONSTRUCTION TYPE TYPE VB, FULLY SPRINKLERED
FIRE RESISTIVE FIRE RESISTIVE
BUILDING ELEMENT RATING REQUIRED RATING PROVIDED
PRIMARY STRUCTURAL
FRAME 0 0
BEARING WALLS
EXTERIOR 0 0
INTERIOR 0 0
EXTERIOR NONBEARING WALLS
AND PARTITIONS 0 0
INTERIOR NONBEARING WALLS
AND PARTITIONS 0 0
FLOOR CONSTRUCTION 0 0
ROOF CONSTRUCTION 0 0
FIRE RESISTIVE REQUIREMENTS
TABLE 601
REFER TO INTERIOR DETAIL SHEET A-57X FOR EXISTING FIRE-PROOFING DETAILS
REFER TO G-141 FOR AREAS WHERE FIRE RESISTIVE RATING ARE IN EXCESS OF TABLE
DISTANCE TO PROPERTY FIRE RESISTIVE
WALL LOCATION LINE OR CL OF ROW RATING PROVIDED
EXTERIOR WALL FIRE RESISTANCE
BASED ON SEPARATION DISTANCE FOR CONSTRUCTION TYPE VB
TABLE 705.5
FIRE AND SMOKE PROTECTION (CHAPTER 7)
CONSTRUCTION TYPE VB, FULLY SPRINKLERED
MAXIMUM AREA OF EXTERIOR WALL OPENINGS
BASED ON FIRE SEPARATION DISTANCE
TABLE 705.8
WALL OPENING PERCENT PERCENT
WALL LOCATION AREA (SF) AREA (SF) ALLOWED
PROPOSED
RECTORY
NORTH 30 20 35% 35%
EAST 30 20 35% 35%
SOUTH 30 20 35% 35%
WEST 30 20 35% 35%
CATHEDRAL CENTER
NORTH 30 20 35% 35%
EAST 30 20 35% 35%
SOUTH 30 20 35% 35%
WEST 30 20 35% 35%
FIRE PROTECTIONS SYSTEMS (CHAPTER 9)
903.3.1.1 (NFPA 13)
EXISTING SPRINKLER SYSTEMS
CATHEDRAL CENTER NONE EXISTING
RECTORY BUILDING NONE EXISTING
CATHEDRAL NONE EXISTING
PROPOSED SPRINKLER SYSTEMS
CATHEDRAL CENTER EQUIPPED THROUGHOUT
RECTORY BUILDING NONE PROPOSED
CATHEDRAL NONE PROPOSED
AUTOMATIC SPRINKLER SYSTEMS
907 (OSSC)
REFER TO FA SERIES DRAWINGS FOR FIRE ALARM AND SMOKE ALARM DESIGN
FIRE ALARM AND PROTECTION SYSTEMS
SECTION 906
REFER TO G-132.P1 & G-133 LIFE SAFETY PLANS FOR FIRE EXTINGUISHER LOCATIONS
RATING MINIMUM 2A10BC
LOCATIONS EACH LEVEL
MAX TRAVEL DISTANCE 75 FEET
PORTABLE FIRE EXTINGUISHERS
MEANS OF EGRESS (CHAPTER 10)
REFER TO G-132.P1 & G-133 LIFE SAFETY PLANS
OCCUPANT LOAD AND EXIT ACCESS
SECTION 1005.3.1
STAIRWAYS 0.3 INCH PER OCCUPANT
OTHER COMPONENTS 0.2 INCH PER OCCUPANT
MEANS OF EGRESS SIZING
TWO-WAY COMMUNICATION IS PROVIDED AT NEW ELEVATOR LANDINGS
TWO-WAY COMMUNICATION
PLUMBING FIXTURES (CHAPTER 29)
MINIMUM REQUIRED PLUMBING FIXTURES (TABLE 2902.1)
PLUMBING FIXTURES PROVIDED BY LEVEL
LEVEL BOTTLE FILLDRINKING FOUNTAINS WATER CLOSETS
MEN WOMEN ALL-GENDER
LAVATORIES
MEN WOMEN ALL-GENDER
GROUND FLOOR 1 1 1 1 1 1 1 1
FIRST FLOOR 1 1 1 1 1 1 1 1
FIRST FLOOR 1 1 1 1 1 1 1 1
REF CIVIL FOR FIRE APPARATUS ACCESS
NORTH
EAST
SOUTH
WEST
>30 FT, REF G-011.P1
>30 FT, REF G-011.P1
>30 FT, REF G-011.P1
>30 FT, REF G-011.P1
0 HR
0 HR
0 HR
0 HR
FIRE RESISTIVE FIRE RESISTIVE
BUILDING ELEMENT (SECT) RATING REQ'D RATING PROVIDED
SHAFT ENCLOSURE (713.4) 1HR (< 4 STORY) 1
EXIT ENCLOSURES (1023.2) 2 2
INCIDENTAL USES (509) NA NA
CONTROL AREAS (414.2.4) NA NA
SEPARATED OCCUPANCIES NA NA
FIRE AREAS (707.3.10) 2 NA
CORRIDOR WALLS (1020.1) 0 0
ELEVATOR LOBBY 0 0
OTHER FIRE A SMOKE PROTECTION ASSEMBLIES
REFERENCE SECTION AS INDICATED
ASSEMBLY
TABLES & CHAIRS
A3LOBBY
GALLERY
10,000
10,000
10,000
1 PER 25 FOR THE
FIRST 50, 1 PER 50
FOR THE REMAINDER
1 PER 125 1 PER 65 1 PER 200 500 9.5 9.5 9.5 9.5 1 PER FLOOR
BUSINESS
OFFICE
BCLASSROOM
VOCATIONAL
10,000
10,000
10,000
500 9.5 9.5 9.5 9.5 1 PER FLOOR
1 PER 40 FOR THE
FIRST 80, 1 PER 50
FOR THE REMAINDER
1 PER 100STORAGE S1STORAGE / MECH 10,000 300 10 5 9.5 9.5 9.5 9.5 1 PER FLOOR1 PER 100
18.5 9.5 9.5 9.5 9.5
1 PER FLOOR19 10 10 10 10ROUNDED TOTAL
FIRE RESISTANCE (CHAPTER 6)
BUILDING A: CONSTRUCTION TYPE IIIB FULLY SPRINKLERED
BUILDING B: CONSTRUCTION TYPE VB FULLY SPRINKLERED
BUILDING C: CONSTRUCTION TYPE VB FULLY SPRINKLERED
CLASSIFICATION DESCRIPTION OCCUPANCY AREA (SF) OLF OCCUPANT
LOAD MEN WOMEN MEN WOMEN
WC PF RATIO LAVATORY PF RATIO
MEN WOMEN MEN WOMEN
WATER CLOSETS LAVATORIES DRINKING FOUNTAINS
PLUMBING
OCCUPANT
LOAD/2
PROJECT DESCRIPTION
GOVERNING CODE
SPECIAL INSPECTIONS
SEE STRUCTURAL DRAWINGS FOR SPECIAL INSPECTIONS REQUIREMENTS.
PHASED BUILDING PERMIT
• PACKAGE 1 : CAFETERIA AND BAND ROOM REMODEL
AND ADDITION (CURRENT APPLICATION)
• PACKAGE 2: SITE PREP (FUTURE)
• PACKAGE 3: FOUNDATIONS AND UNDERGROUND UTILITIES (FUTURE)
• PACKAGE 4: BUILDING SHELL AND INTERIOR (FUTURE)
THE PROJECT INCLUDES FOUR PHASES:
PHASE 1: REMODEL OF EXISTING CAFETERIA, AND BAND ROOM INTO A NEW BAND
ROOM, TOILET ROOMS AND AN ELEVATOR THAT CONNECTS ALL FOUR FLOORS OF
THE EXISTING BUILDING.
PHASE 2: SITE PREP PACKAGE FOR THE NEW AUDITORIUM
PHASE 3: FOUNDATIONS AND UNDERGROUND UTILITIES FOR THE NEW AUDITORIUM
PHASE 4: BUILDOUT OF THE NEW AUDITORIUM. THE AUDITORIUM WILL CONSIST OF
A LOBBY, GREEN ROOM / DRESSING ROOMS, FIXED SEATING HOUSE, AND ELEVATED
STAGE. THE AUDITORIUM WILL SEAT 299.
THE FOLLOWING SYSTEMS ARE SUBJECT TO DEFERRED SUBMITTALS IN ACCORDANCE
WITH OSSC 107:
REFER TO STRUCTURAL SHEETS FOR ADDITIONAL INFORMATION ON ALL
STRUCTURAL DEFERRED SUBMITTALS LISTED BELOW:
ARCHITECTS
CONSULTANT
STAMP
REVISION NO. DATE
KEY PLAN - (NTS)
SHEET NUMBER
DRAWING TITLE
SCALE
DATE
PROJECT NUMBER
ISSUANCE
NOT FOR
CONSTRUCTION
12" = 1'-0"
G-111.1
06/01/26
25035
TOLEDO HIGH
SCHOOL
AUDITORIUM
LINCOLN COUNTY SCHOOL DISTRICT
1800 N.E. STURDEVANT RD.
TOLEDO, OREGON 97391
CODE NARRATIVE
PACKAGE 1: RENOVATION
J
L
0.5 1.5
K
1.2
I
AREA LEGEND
S-1
135 SF
S-1
WATER
175 SF
S-1
ELECTRICAL
FUTURE
SCOPE
1.7 3.5
FIRE EXTINGUISHER
CABINET, SEE
ACCESSORY USE*
ACCESSIBLE EXIT
EXIT (WITH NUMBER OF OCCUPANTS)
FEC
OCCS
COMPONENT
XX" MIN REQD
MIN PRVD
EGRESS COMPONENT WIDTH DATA
ROOM OR AREA NAME
# SF
OLF
OL
OG
Area
OCCUPANT LOAD FACTOR
(NET OR GROSS)
2 HOUR RATED FIRE WALL
PATH OF EGRESS, 36" MINIMUM
CLEARANCE. ILLUMINATION 1 FT
CANDLE/FT AT FLOOR. PROVIDE 90
MIN BACKUP POWER
1 HOUR RATED FIRE BARRIER
NUMBER OF OCCUPANTS
OCCUPANCY CLASS
GENERAL NOTES
1. SEE ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTING
AND POWER SYSTEMS, FIRE ALARM, EMERGENCY
VOICE/ALARM COMMUNICATIONS SYSTEM.
LIFE SAFETY PLAN LEGEND
A-585.1
EXISTING
FUTURE SCOPE
W
EXIT LIGHTING
C F P
W C F P
(E) FIRE EXTINGUISHER
CABINET
FEC
(E) (E) (E) (E)
INDICATES DIRECTION
(E)
(E) 2 HOUR RATED FIRE WALL
2 HOUR RATED FIRE WALL -
FUTURE SCOPE
INDICATES HOST - WALL, CEILING,
FLAG, PENDANT
EXIT LIGHTING
INDICATES DIRECTION
INDICATES HOST - WALL, CEILING,
FLAG, PENDANT
ARCHITECTS
CONSULTANT
STAMP
REVISION NO. DATE
KEY PLAN - (NTS)
SHEET NUMBER
DRAWING TITLE
SCALE
DATE
PROJECT NUMBER
ISSUANCE
TRUE
NORTH
PLAN
NORTH
NOT FOR
CONSTRUCTION
As indicated
G-131
06/01/26
25035
TOLEDO HIGH
SCHOOL
AUDITORIUM
LINCOLN COUNTY SCHOOL DISTRICT
1800 N.E. STURDEVANT RD.
TOLEDO, OREGON 97391
LIFE SAFETY PLAN -
BASEMENT
PACKAGE 1: RENOVATION
DIRECTIONAL ARROW
SIGN FACING DIRECTION
MOUNTING STYLE
EXIT SIGN MOUNTING STYLE:
C = CEILING MOUNT
P = PENDANT MOUNT
W = WALL MOUNT
F = FLAG MOUNT
EXIT SIGN SYMBOL
CC
3/32" = 1'-0" G-131
1 LIFE SAFETY OVERALL - LEVEL 01 Copy 1
UP
UP
1 2 3 55.1
7 8 9
A
B
C
D
E
F
H
J
L
0.5 1.5 3.3
K
1.2
I
4.5
2598 SF
A-2
CAFETERIA
OCCS
EXIT
76" MIN REQD
76" PRVD
OCCS
EXIT
32" MIN REQD
36" PRVD
OCCS
EXIT
32" MIN REQD
72" EXISTING
1771 SF
A-1
STAGE
357 SF
A-1
GREEN ROOM /
DRESSING ROOM
3173 SF
A-1
AUDITORIUM
22 SF
S-1
JANITOR
AREA LEGEND
A-1
A-2
A-3
B
E
S-1
SI1
EXISTING DOOR
2015 SF
A-3
LOBBY
211 SF
S-1
STORAGE
142 SF
S-1
LIGHTING
CONTROL ROOM
181 SF
S-1
AV EQUIPMENT
155 155
44 SF
A-1
CHANGE 1
28 SF
A-1
CHANGE 2
28 SF
A-1
CHANGE 3
COURTYARD
FUTURE
SCOPE
1.7
1 HR RATED FIRE
BARRIER
2 HR RATED FIRE WALL (FUTURE SCOPE)
210 SF
S-1
STORAGE
91 SF
E
PRACTICE 1
106 SF
B
OFFICE
91 SF
E
PRACTICE 2
458 SF
E
BAND ROOM
ADDITION
864 SF
E
BAND ROOM
FEC
W
W
31' - 3"
CAFETERIA MAX. DIAGONAL = 67' - 1"
1/3 DISTANCE = 22' - 4 5/16"
W
(E)
CAFETERIA MAX. DIAGONAL = 94' - 4"
1/3 DISTANCE = 31' - 5 5/16"
40' - 1"
F E
C
(E)
W W W
(E)
(E) 2 HOUR FIRE RATED WALL
OCCS
EXIT
32" MIN REQD
72" EXISTING
543 SF
S-1
(E) BOILER
928 SF
A-2
(E) KITCHEN
142 SF
SI1
(E) STORAGE
3.5
2 HOUR FIRE RATED WALL
FIRE EXTINGUISHER
CABINET, SEE
ACCESSORY USE*
ACCESSIBLE EXIT
EXIT (WITH NUMBER OF OCCUPANTS)
FEC
OCCS
COMPONENT
XX" MIN REQD
MIN PRVD
EGRESS COMPONENT WIDTH DATA
ROOM OR AREA NAME
# SF
OLF
OL
OG
Area
OCCUPANT LOAD FACTOR
(NET OR GROSS)
2 HOUR RATED FIRE WALL
PATH OF EGRESS, 36" MINIMUM
CLEARANCE. ILLUMINATION 1 FT
CANDLE/FT AT FLOOR. PROVIDE 90
MIN BACKUP POWER
1 HOUR RATED FIRE BARRIER
NUMBER OF OCCUPANTS
OCCUPANCY CLASS
GENERAL NOTES
1. SEE ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTING
AND POWER SYSTEMS, FIRE ALARM, EMERGENCY
VOICE/ALARM COMMUNICATIONS SYSTEM.
LIFE SAFETY PLAN LEGEND
A-585.1
EXISTING
FUTURE SCOPE
W
EXIT LIGHTING
C F P
W C F P
(E) FIRE EXTINGUISHER
CABINET
FEC
(E) (E) (E) (E)
INDICATES DIRECTION
(E)
(E) 2 HOUR RATED FIRE WALL
2 HOUR RATED FIRE WALL -
FUTURE SCOPE
INDICATES HOST - WALL, CEILING,
FLAG, PENDANT
EXIT LIGHTING
INDICATES DIRECTION
INDICATES HOST - WALL, CEILING,
FLAG, PENDANT
Group A-1 (Assembly) – 440 Occupants
Male 220; Female 220
Per OSSC, Male WC 1 per 125; Female WC 1 per 65
Male/Female Lavatories 1 per 200; Drinking fountains 1 per floor
WC = 1.76 Male; 3.4 Female; Lavatories = 1.1 Male; 1.1 Female
Group A-3 (Assembly) – 136 Occupants
Male 68; Female 68
Per OSSC, Male WC 1 per 125; Female WC 1 per 65
Male/Female Lavatories 1 per 200; Drinking fountains 1 per floor
WC = 0.54 Male; 1.05 Female; Lavatories = 0.34 Male; 0.34 Female
Group E (Educational) – 23 Occupants
Male 11; Female 12
Per OSSC, Male / Female WC 1 per 50;
Male/Female Lavatories 1 per 50; Drinking fountains 1 per floor
WC = 0.22 Male; 0.24 Female; Lavatories = 0.22 Male; 0.24 Female
Group S-1 (Storage) – 5 Occupants
Male 2; Female 3
Per OSSC, Male/Female WC 1 per 100
Male/Female Lavatories 1 per 100
WC = 0.02 Male; 0.03 Female; Lavatories = 0.02 Male; 0.03 Female
TOTAL REQUIRED
WC = 2.54 Male; 4.72 Female; Lavatories = 1.68 Male; 1.71 Female
TOTAL PROVIDED
All User RR; WC = 9, Lavatories = 6
Dressing Room RR; WC = 1, Lavatories = 1
RESTROOM CALCULATION OVERALL (PACKAGE 1 & 4)
ARCHITECTS
CONSULTANT
STAMP
REVISION NO. DATE
KEY PLAN - (NTS)
SHEET NUMBER
DRAWING TITLE
SCALE
DATE
PROJECT NUMBER
ISSUANCE
TRUE
NORTH
PLAN
NORTH
NOT FOR
CONSTRUCTION
As indicated
G-132
06/01/26
25035
TOLEDO HIGH
SCHOOL
AUDITORIUM
LINCOLN COUNTY SCHOOL DISTRICT
1800 N.E. STURDEVANT RD.
TOLEDO, OREGON 97391
LIFE SAFETY PLAN - LEVEL
01, 02 & 03
PACKAGE 1: RENOVATION
DIRECTIONAL ARROW
SIGN FACING DIRECTION
MOUNTING STYLE
EXIT SIGN MOUNTING STYLE:
C = CEILING MOUNT
P = PENDANT MOUNT
W = WALL MOUNT
F = FLAG MOUNT
EXIT SIGN SYMBOL
CC
1/16" = 1'-0" G-132
1 LIFE SAFETY OVERALL - LEVEL 01, 02 & 03
KEY - FUNCTION OF SPACE
Function of Space
Occupant
Load Factor
Net or
Gross
Accessory storage areas, mechanical equipment room 300 Gross
Assembly - Standing space 5 Net
Assembly - Unconcentrated (tables and chairs) 15 Net
Business area 150 Gross
Educational - Classroom Area 20 Net
Industrial areas 100 Gross
Institutional - Inpatient treatment areas 240 Gross
Kitchen, commercial - associated with dining facility 200 Gross
Library reading rooms 50 Gross
Library stack area 100 Gross
Locker rooms 50 Gross
Mercantile 60 Gross
Parking garages 200 Gross
Residential 200 Gross
Unoccupied accessory areas 0 Gross
AREA SCHEDULE - RESTROOM CALCULATION
NAME AREA
NET /
GROSS
OCC LOAD
FACTOR
OCC
GROUP
OCC
LOAD
A-1
STAGE 1771.32 SF Net 15 A-1 119
GREEN ROOM /
DRESSING ROOM
356.77 SF Net 50 A-1 8
AUDITORIUM 3172.60 SF Net A-1 310
CHANGE 1 44.30 SF Net 50 A-1 1
CHANGE 2 27.65 SF Net 50 A-1 1
CHANGE 3 27.65 SF Net 50 A-1 1
A-3
LOBBY 2015.17 SF Net 15 A-3 136
E
BAND ROOM ADDITION 457.55 SF Net 20 E 23
S-1
AV EQUIPMENT 180.52 SF Gross 300 S-1 1
WATER 135.48 SF Gross 300 S-1 1
ELECTRICAL 174.86 SF Gross 300 S-1 1
STORAGE 211.37 SF Gross 300 S-1 1
LIGHTING CONTROL
ROOM
142.34 SF Gross 300 S-1 1
1 2 3 5 6 7 8 9
A
B
C
D
E
F
G
H
J
L
0.5 3.3
K
1.2
I
4.5
COURTYARD
BELOW
FUTURE
SCOPE
1.7
W
W
1 HR RATED FIRE
BARRIER
(E) 2 HOUR FIRE WALL
(E) 2 HOUR RATED FIRE WALL
W
(E)
3.5
2 HOUR RATED
FIRE WALL
FIRE EXTINGUISHER
CABINET, SEE
ACCESSORY USE*
ACCESSIBLE EXIT
EXIT (WITH NUMBER OF OCCUPANTS)
FEC
OCCS
COMPONENT
XX" MIN REQD
MIN PRVD
EGRESS COMPONENT WIDTH DATA
ROOM OR AREA NAME
# SF
OLF
OL
OG
Area
OCCUPANT LOAD FACTOR
(NET OR GROSS)
2 HOUR RATED FIRE WALL
PATH OF EGRESS, 36" MINIMUM
CLEARANCE. ILLUMINATION 1 FT
CANDLE/FT AT FLOOR. PROVIDE 90
MIN BACKUP POWER
1 HOUR RATED FIRE BARRIER
NUMBER OF OCCUPANTS
OCCUPANCY CLASS
GENERAL NOTES
1. SEE ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTING
AND POWER SYSTEMS, FIRE ALARM, EMERGENCY
VOICE/ALARM COMMUNICATIONS SYSTEM.
LIFE SAFETY PLAN LEGEND
A-585.1
EXISTING
FUTURE SCOPE
W
EXIT LIGHTING
C F P
W C F P
(E) FIRE EXTINGUISHER
CABINET
FEC
(E) (E) (E) (E)
INDICATES DIRECTION
(E)
(E) 2 HOUR RATED FIRE WALL
2 HOUR RATED FIRE WALL -
FUTURE SCOPE
INDICATES HOST - WALL, CEILING,
FLAG, PENDANT
EXIT LIGHTING
INDICATES DIRECTION
INDICATES HOST - WALL, CEILING,
FLAG, PENDANT
ARCHITECTS
CONSULTANT
STAMP
REVISION NO. DATE
KEY PLAN - (NTS)
SHEET NUMBER
DRAWING TITLE
SCALE
DATE
PROJECT NUMBER
ISSUANCE
TRUE
NORTH
PLAN
NORTH
NOT FOR
CONSTRUCTION
As indicated
G-133
06/01/26
25035
TOLEDO HIGH
SCHOOL
AUDITORIUM
LINCOLN COUNTY SCHOOL DISTRICT
1800 N.E. STURDEVANT RD.
TOLEDO, OREGON 97391
LIFE SAFETY PLAN - LEVEL
04 & 05
PACKAGE 1: RENOVATION
DIRECTIONAL ARROW
SIGN FACING DIRECTION
MOUNTING STYLE
EXIT SIGN MOUNTING STYLE:
C = CEILING MOUNT
P = PENDANT MOUNT
W = WALL MOUNT
F = FLAG MOUNT
EXIT SIGN SYMBOL
C
1/16" = 1'-0" G-133
1 LIFE SAFETY OVERALL - LEVEL 04 & 05
REFER TO ANSI 117.3, 2003 FOR ADA INFORMATION.
:5
:1
R A
T
IO
3:5 - 1:1
RATIO
/8
M
IN
TEXT
MATERIAL: 1/16" PHOTOPOLYMER
FONT: TO BE DETERMINED BY OWNER
FINISH: CUSTOM COLOR TO MATCH WALL PNT
ATTACHMENT METHOD: SNOT TAPE OR SIM, MUST BE TIGHTLY FIT TO WALL
TEXT MUST BE ALL CAPS IN A SANS-SERIF OR SIMPLE SERIF STYLE
CAP HEIGHT MUST BE BETWEEN 5/8" AND 2"; MEASURE USING CHARACTER "X"
RATIO OF CHARACTER WIDTH TO HEIGHT BETWEEN 3:5 AND 1:1
PERMANENT ROOM ID TEXT MUST BE TACTILE, RAISED 1/32" ABOVE SIGN FACE
" 123"
MATERIAL: 3/8" ANODIZED BLACK ALUMINUM, INDIVIDUAL #'S
FONT: TO BE DETERMINED BY OWNER
ATTACHMENT METHOD: BIDDER DESIGNED
4" WIDE
R E
Q 'D
/2
M
IN
MATERIAL: 1/16" PHOTOPOLYMER
FONT: TO BE DETERMINED BY OWNER
FINISH: CUSTOM COLOR T MATCH WALL PNT
ATTACHMENT METHOD: SNOT TAPE OR SIM, MUST BE TIGHTLY FIT TO WALL
RATIO OF CHARACTER WIDTH TO HEIGHT BETWEEN 3:5 AND 1:1
PERMANENT ROOM ID TEXT MUST BE TACTILE, RAISED 1/32" ABOVE SIGN FACE
M
IN
H E
IG
H
T R
E Q
'D
*GC RESPONSIBLE FOR CONFIRMING SITE ADDRESS
3325*4
M
IN
MATERIAL: WHITE VINYL LETTERING CENTERED ON GLAZING PANEL, PER DRAWINGS
FONT: TO BE DETERMINED BY OWNER
1/2" MIN
NEW AND EXISTING BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION
PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. THESE NUMBERS SHALL
CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE ARABIC NUMERALS OR ALPHABET LETTERS. NUMBERS SHALL NOT BE
SPELLED OUT. NUMBERS SHALL BE A MINIMUM OF 4 INCHES (102 MM) HIGH WITH A MINIMUM STROKE WIDTH OF 0.5 INCH (12.7 MM).
2019 OREGON FIRE CODE:
505.1 ADDRESS NUMBERS
MUST BE A MINIMUM 70% CONTRAST BETWEEN FIGURE AND GROUND
CHARACTER AND BACKGROUND MUST BE MATTE, EGGSHELL OR OTHER NON-GLARE MATERIAL
SIGNAGE AND CONTRAST
RAISED DOT
MUST BE
BETWEEN .017"
AND .022"
ELEVATION SECTION
HEIGHT OF
. 0.241
.0
.3
.0
MESSAGE AREA
GRADE 2 BRAILLE
FINISH FLOOR
M
IN
M
A X
CENTER LINE OF
TACTILE/BRAILLE
MESSAGE TO BE
PLACED 60" MAX ABOVE
FINISH FLOOR.
SIGNAGE TO BE PLACED
ON LATCH SIDE OF DOOR
OVERHEAD
SIGNAGE MUST BE
80" CLEAR ABOVE
FINISH FLOOR
M
IN
C
LR
ROOM NAME / FLOOR NUMBER
BRAILLE
DOES NOT APPLY TO
APARTMENT UNIT SIGNAGE
/4
M
IN
/8
M
IN
ROOM NUMBER
/2
M
IN
3* CENTER LINE OF
CHARACTER at 60"
ABOVE FINISH FLOOR
FLOOR LEVEL INDICATOR
MINIMUM 2" HIGH
USE GRADE 2 BRAILLE,
MINIMUM .5" HIGH
FLOOR LEVEL INDICATOR ON
HOISTWAY DOOR at GROUND
FLOOR
USE STAR OR ASTERISK
AT GROUND FLOOR
CENTER LINE OF
CHARACTER at 60"
ABOVE FINISH FLOOR
FLOOR LEVEL INDICATOR
MINIMUM 2" HIGH
USE GRADE 2 BRAILLE,
MINIMUM .5" HIGH
FLOOR LEVEL INDICATOR ON
HOISTWAY DOOR ABOVE OR
BELOW GROUND FLOOR
A SIGN SHALL BE PROVIDED AT EACH FLOOR LANDING IN AN INTERIOR EXIT STAIRWAY AND RAMP CONNECTING MORE THAN THREE STORIES
DESIGNATING THE FLOOR LEVEL, THE TERMINUS OF THE TOP AND BOTTOM OF THE INTERIOR EXIT STAIRWAY AND RAMP AND THE
IDENTIFICATION OF THE STAIR OR RAMP. THE SIGNAGE SHALL ALSO STATE THE STORY OF, AND THE DIRECTION TO, THE EXIT DISCHARGE AND
THE AVAILABILITY OF ROOF ACCESS FROM THE INTERIOR EXIT STAIRWAY AND RAMP FOR THE FIRE DEPARTMENT. THE SIGN SHALL BE LOCATED
5 FEET ABOVE THE FLOOR LANDING IN A POSITION THAT IS READILY VISIBLE WHEN THE DOORS ARE IN THE OPEN AND CLOSED POSITIONS.
2019 OREGON STRUCTURAL SPECIALTY CODE :
1023.9 STAIRWAY IDENTIFICATION SIGNS
Roof Access
Floors 1−Roof
STAIR 1
STAIR IDENTIFICATION
TERMINUS OF TOP
AND BOTTOM
LEVELS OF STAIR
FLOOR LEVEL
CENTER LINE OF SIGN at 60" ABOVE
FINISH FLOOR
"ROOF ACCESS"
AT ALL STAIRWAYS
M
IN
12" MIN
ELEVATOR DOOR
CALL LANTERN
FLOOR LEVEL
CALL BUTTON
STAR OF LIFE SYMBOL
(AMBULATORY STRETCHER ELEVATOR(S)
SEE 15/A002, SEE PLANS.
8"
INTERNATIONAL
MEDICAL SERVICES
(STAR OF LIFE)
ELEVATOR JAMB, SEE
PLAN
EQ EQ
MOUNT AT +5'-0" AFF
IN CASE OF
FIRE USE
STAIRS
BRAILLE TEXT
FIREFIGHTER'S OPERATION
TO RECALL ELEVATORS
INSERT FIRE KEY AND
TURN TO "ON"
ELEVATOR
EMERGENCY POWER
ELEVATOR INTERCOM
PUSH AND HOLD
(SPEAKER)
(SPEAKER)
(SPEAKER BUTTONS)
(FIREMAN KEY)
(BUTTON TO CALL
ELEVATOR DOWN)
FIREFIGHTER'S
PHONE JACK
"IN CASE OF FIRE
USE STAIR FOR
EXIT" (GRAPHIC)
(BUTTON TO CALL
ELEVATOR DOWN)
(FIREFIGHTER'S
PHONE JACK)
(BUTTON TO CALL
ELEVATOR UP)
(BUTTON TO CALL
ELEVATOR UP)
FIREFIGHTER'S
PHONE JACK
"IN CASE OF FIRE
USE STAIR FOR
EXIT" (GRAPHIC)
(FIREFIGHTER'S
PHONE JACK)
TYPICAL GROUND FLOOR - ELEVATORS UP & DOWN TYPICAL UPPER & LOWER FLOORS
A
B V
F F
T Y
P
O F
B U
T T
O N
S
A
B V
F F
T Y
P
O F
B U
T T
O N
S
TEXT
SYMBOLS USED FOR
PERMANENT ROOM
IDENTIFICATION MUST BE
ACCOMPANIED BY TEXT AND BRAILLE
WHICH CONFORM TO THE ADA TEXT
GUIDELINES
SYMBOL
SMOKING IS PROHIBITED
WITHIN 10 FEET
1 1/2" TALL VINYL
LETTERING ON
STOREFRONT GLAZING
VINYL GRAPHIC ON
STOREFRONT GLAZING
TYPICAL CODE REQUIRED SIGNAGE:
1. RESTROOM SIGNAGE.
2. ASSEMBLY OCCUPANCY SPACES SHALL HAVE MAX OCCUPANT LOADS POSTED WITHIN
SPACE AT A CONSPICUOUS LOCATION, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY.
REFERENCE OSSC 1004.9.
3. TWO-WAY COMMUNICATIONS SYSTEM DIRECTIONS AND INSTRUCTIONS ADJACENT TO
TWO-WAY COMMUNICATION SYSTEM. REFERENCE OSSC 1009.8.2.
4. SIGNAGE IDENTIFYING AREAS OF REFUGE AND EXTERIOR AREAS FOR ASSISTED RESCUE.
IDENTIFICATION AND INSTRUCTIONS ON THE USE OF THE AREA UNDER EMERGENCY
CONDITIONS TO BE POSTED. REFERENCE OSSC 1009.9 AND 1009.11.
5. SIGNAGE IDENTIFYING FIRE RISER ROOM.
6. SIGNAGE IDENTIFYING FIRE ALARM CONTROL PANEL.
ARCHITECTS
CONSULTANT
STAMP
REVISION NO. DATE
KEY PLAN - (NTS)
SHEET NUMBER
DRAWING TITLE
SCALE
DATE
PROJECT NUMBER
ISSUANCE
NOT FOR
CONSTRUCTION
As indicated
G-201
06/01/26
25035
TOLEDO HIGH
SCHOOL
AUDITORIUM
LINCOLN COUNTY SCHOOL DISTRICT
1800 N.E. STURDEVANT RD.
TOLEDO, OREGON 97391
CODE SIGNAGE
STANDARDS
PACKAGE 1: RENOVATION
n.t.s.G-201
1 SIGN TEXT
n.t.s.G-201
2 UNIT IDENTIFICATION SIGNAGE - TYPE A
n.t.s.G-201
3 UNIT ADA + BRAILLE SIGNAGE - TYPE B
n.t.s.G-201
4 EXTERIOR BUILDING ADDRESS
n.t.s.G-201
5 COLOR CONTRAST
n.t.s.G-201
6 GRADE 2 BRAILLE
n.t.s.G-201
7 TACTILE / BRAILLE SIGN MOUNTING
n.t.s.G-201
13 SIGN LOCATIONS
n.t.s.G-201
9 TACTILE/BRAILLE SIGN, TYP
n.t.s.G-201
10 FLOOR INDICATOR AT HOISTWAY DOOR
n.t.s.G-201
11 FLOOR LEVEL INDICATOR
n.t.s.G-201
12 STAIRWELL SIGNAGE
n.t.s.G-201
14 ELEVATOR DOOR SIGNS / LAYOUT
n.t.s.G-201
15 STAR OF LIFE SYMBOL
n.t.s.G-201
19 IN CASE OF FIRE SIGN
n.t.s.G-201
20 ELEVATOR CALL BUTONS - FOR REFERENCE ONLY
n.t.s.G-201
8 USING SYMBOLS
n.t.s.G-201
18 NO SMOKING BUILDING SIGNAGE
n.t.s.G-201
17 GENERAL CODE REQUIRED SIGNAGE
CAFETERIA
JANITOR
ALL USER RR
D.1
C.1
C.1
C.4 C.2
C.2
C.2
C.2
C.2 C.3.1
C.2
C.2
E.1 D.1 D.1
PRACTICE 1
PRACTICE 2
BAND ROOM
BAND STORAGE
BAND ROOM ENTRY
OFFICE
ELEVATOR VEST
D.1
D.1
D.1
D.1
D.1
D.1D.1
HATCH INDICATES
EXISTING, NIC
HATCH INDICATES
EXISTING, NIC
(E) FLOOR
FRAMING TO
REMAIN
(N) FLOOR
LVL 04 CORR
D.1
UP
UP
HATCH INDICATES
EXISTING, NIC
HATCH INDICATES
EXISTING, NIC
LVL 05 CORR
D.1 E.1
GENERAL NOTES - CODE SIGNAGE
A. REFERENCE G-201 FOR SIGNANGE STANDARDS.
B. ALL SIGNAGE MESSAGING AND CONTENT TO BE
CONFIRMED BY OWNER DURING SUBMITTAL REVIEW.
@ PT 1 AND PT 2 WALLS
SUBSTRATE : PT 3
MESSAGE : WHITE
@ GLASS RELITE
SUBSTRATE : FROSTED MATTE ACYLIC W/ BACKPAINT
LIGHT GREY (COLOR TBD)
MESSAGE: PT 3 - KENDALL CHARCOAL
TYPEFACE:
SOLEIL
BRAILLE:
PROVIDE DTS RAISED DOTS TO MATCH SIGN COLOR
SIGNAGE COLOR STANDARDS
A.1
SIGNAGE LEGEND
OFFICE/MEETING ROOM - GLASS MOUNTED
B.1 CLASSROOM - GLASS MOUNTED
C.1 ALL USER RESTROOMS AND SHOWER - MAIN
ENTRY
C.2 ALL USER RESTROOM - COMPARTMENT
C.3.1 ALL USER RESTROOM - ADA SINGLE OCC.
C.4 ALL USER RESTROOM - AMBULATORY STALL
C.5 ALL USER RESTROOM - ADA SHOWER SINGLE OCC.
D.1 ROOM NAME SIGN - INTERIOR
D.2 ROOM NAME SIGN - EXTERIOR SIDING MOUNT
E.1 CODE - EXIT
E.2 CODE - EXIT DIRECTIONAL - NOT USED
E.3 CODE - EVACUATION MAP
E.4 CODE - FIRE ALARM CONTROL PANEL
E.5 CODE - BUILDING NAME OR NUMBER AS
REQUESTED BY FIRE DEPARMENT
C.3.2 ALL USER RESTROOM - ADA SINGLE OCC. W/ BABY
CHANGING STATION
E.6 CODE - NO SMOKING NEAR ENTRY - VINYL
E.7 HAZARDOUS MATERIAL NOTICE
11"
/2
FIRE EXIT ROUTE
LOCATION FOR MESSAGE IN BRAILLE
/2
/4
" 1 /4
/8
/8
/2
/4
SPACE ALLOWS FOR A
11"X8.5" INSERT
/4
EXIT
LOCATION FOR NAME AND NUMBER IN BRAILLE
1/2"
/4
/8
/4
8 1/2"
/1
PLAN MAP TBD
ALL USER
TOILET
LOCATION FOR NAME AND NUMBER IN BRAILLE
/8
6 1/2"
/4
1/2" 5 1/4" 3/4"
/3
/8
/1
"9 /3
LOCATION FOR NAME AND NUMBER IN BRAILLE
ONE LINE NAME
1/2"
/4
/8
TWO LINE NAME
/4
/8
/3
/8
/3
/4
8 1/2"
3/4"
START TEXT HERE
/1
ALL USER
RESTROOM
LOCATION FOR NAME AND NUMBER IN BRAILLE
/8
6 1/2"
/4
1/2" 5 1/4" 3/4"
/3
/8
/1
"9 /3
" ALL USER
AMBULANT
LOCATION FOR NAME AND NUMBER IN BRAILLE
/8
6 1/2"
/4
1/2" 5 1/4" 3/4"
/3
/8
/1
"9 /3
A.1
B.1
C.1
D.1
D.2
C.2 C.3.1
C.3.2
C.4
*OMIT BABY CHANGING STATION ICON
FOR SIGN C.3.1
/4
/4
/4
E.1
E.3
E.4
E.7
ARCHITECTS
CONSULTANT
STAMP
REVISION NO. DATE
KEY PLAN - (NTS)
SHEET NUMBER
DRAWING TITLE
SCALE
DATE
PROJECT NUMBER
ISSUANCE
NOT FOR
CONSTRUCTION
As indicated
G-202
06/01/26
25035
TOLEDO HIGH
SCHOOL
AUDITORIUM
LINCOLN COUNTY SCHOOL DISTRICT
1800 N.E. STURDEVANT RD.
TOLEDO, OREGON 97391
CODE SIGNAGE PLAN
PACKAGE 1: RENOVATION
1" = 10'-0" G-202
1 FLOOR PLAN - LEVEL 02 - SIGNAGE
1" = 10'-0" G-202
2 FLOOR PLAN - LEVEL 03 - SIGNAGE
1" = 10'-0" G-202
3 FLOOR PLAN - LEVEL 04 - SIGNAGE
1" = 10'-0" G-202
4 FLOOR PLAN - LEVEL 05 - SIGNAGE
LIST OF ABBREVIATIONS
A.B. ANCHOR BOLT
ACI AMERICAN CONCRETE INSTITUTE
ADD'L. ADDITIONAL
AESS ARCHITECTURALLY EXPOSED
STRUCTURAL STEEL
AISC AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
ALT. ALTERNATE
ALUM. ALUMINUM
ARCH. ARCHITECT / ARCHITECTURAL
ASCE AMERICAN SOCIETY OF CIVIL
ENGINEERS
ASD ALLOWABLE STRENGTH DESIGN
LOAD LEVEL
ASTM AMERICAN SOCIETY FOR
TESTING AND MATERIALS
AWS AMERICAN WELDING SOCIETY
BLDG. BUILDING
BOT. BOTTOM
BRBF BUCKLING RESTRAINED BRACED
FRAME
C.G. CENTER OF GRAVITY
C.I.P. CAST IN PLACE
C.J. CONTROL JOINT
C.J.P. COMPLETE JOINT PENETRATION
CL CENTERLINE
CLR. CLEAR
CLT CROSS LAMINATED TIMBER
CMU CONCRETE MASONRY UNIT
COL. COLUMN
CONC. CONCRETE
CONN. CONNECTION
CONST. CONSTRUCTION
CONT. CONTINUOUS
db BAR DIAMETER
DBA DEFORMED BAR ANCHOR
DET. DETAIL
DIA., Ø DIAMETER
DIAG. DIAGONAL
D.L. DEAD LOAD
DLT DOWEL LAMINATED TIMBER
DWG. DRAWING
ELEC. ELECTRICAL
EL. ELEVATION
EQ. EQUAL
EXIST., (E) EXISTING
EXP. EXPANSION
EXT. EXTERIOR
FDN. FOUNDATION
FIN. FINISH
FLR. FLOOR
FRT FIRE RETARDANT TREATED
FT. FOOT
FTG. FOOTING
GA. GAUGE
GALV. GALVANIZED
GL GLULAM
HORIZ. HORIZONTAL
HSS HOLLOW STRUCTURAL STEEL
IBC INTERNATIONAL BUILDING CODE
I.D. INSIDE DIAMETER
IN. INCHES
INT. INTERIOR
K KIPS
KSF KIPS PER SQUARE FOOT
KSI KIPS PER SQUARE INCH
LBS. POUNDS
L.L. LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LOC. LOCATION
LONG. LONGITUDINAL
LSL LAMINATED STRAND LUMBER
LVF LOW VELOCITY FASTENER
LVL LAMINATED VENEER LUMBER
MAX. MAXIMUM
MBMA METAL BUILDING MANUFACTURERS
ASSOCIATION
MECH. MECHANICAL
MEPF MECHANICAL, ELECTRICAL, PLUMBING
AND FIRE SAFETY
MFR. MANUFACTURER
MIN. MINIMUM
MISC. MISCELLANEOUS
MPH MILES PER HOUR
MPP MASS PLYWOOD PANELS
MT MAGNETIC PARTICLE TESTING
(N) NEW
N.I.C. NOT IN CONTRACT
NLT NAIL LAMINATED TIMBER
NOM. NOMINAL
NO. NUMBER
N.T.S. NOT TO SCALE
o.c. ON CENTER
O.D. OUTSIDE DIAMETER
OPP. OPPOSITE
OSL ORIENTED STRAND LUMBER
OWJ OPEN WEB JOIST
PAF POWDER ACTUATED FASTENER
PART. PARTITION
P/C PRECAST
PCF POUNDS PER CUBIC FOOT
PERIM. PERIMETER
PL PLATE
PP PARTIAL PENETRATION
PSF POUNDS PER SQUARE FOOT
PSL PARALLEL STRAND LUMBER
PSI POUNDS PER SQUARE INCH
P/T POST-TENSIONED
P.T. PRESSURE TREATED
PVC POLYVINYL CHLORIDE
R, RAD. RADIUS
RCSC RESEARCH COUNCIL ON
STRUCTURAL CONNECTIONS
REF. REFERENCE
RET. RETURN
REINF. REINFORCING
REQ'D. REQUIRED
REQ'MTS. REQUIREMENTS
SCHED. SCHEDULE
S.C. SLIP CRITICAL
SCL STRUCTURAL COMPOSITE LUMBER
SIM. SIMILAR
SLFS SEISMIC FORCE RESISTING SYSTEM
S.O.G. SLAB ON GRADE
SPEC. SPECIFICATION
SQ. SQUARE
SS STAINLESS STEEL
SSMA STEEL STUD MANUFACTURERS
ASSOCIATION
STD. STANDARD
STRUCT. STRUCTURAL
SYM. SYMMETRICAL
THRU THROUGH
T&G TONGUE AND GROOVE
TRANS. TRANSVERSE
TS LIGHT GAUGE TUBE STEEL
TYP. TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
U.T. ULTRASONIC TESTING
ULT. ULTIMATE STRENGTH DESIGN LOAD LEVEL
VERT. VERTICAL
V.I.F. VERIFY IN FIELD
w/ WITH
WF WIDE FLANGE
w/o WITHOUT
W.P. WORK POINT
WPS WELDING PROCEDURE
SPECIFICATION
WWF WELDED WIRE FABRIC
N
79476PE
13, OREGON
EXPIRES
MAR.
NE
G I
S T R U C T
702 0
REE
RU LA
R I C H A RD S
P.AUHSOJ
PROFESS I ONA L
DERETSI
GER
111 SW Fifth Ave., Suite 2600
Portland, OR 97204
O: 503.227.3251
F: 503.227.7980 www.kpff.com
ARCHITECTS
CONSULTANT
STAMP
REVISION NO. DATE
KEY PLAN - (NTS)
SHEET NUMBER
DRAWING TITLE
SCALE
DATE
PROJECT NUMBER
ISSUANCE
TRUE
NORTH
PLAN
NORTH
10022500757 R-24
12-13-26
1 : 1
/1
/2
:0
:3
P
M
A u to d e s k D o c s /1
L C
S D
T o le d o
H S
A u d it o ri u m
/1
R
-2 .r v t
S-001.1
6/1/2026
25035
TOLEDO HIGH
SCHOOL
AUDITORIUM
LINCOLN COUNTY SCHOOL DISTRICT
1800 N.E. STURDEVANT RD.
TOLEDO, OREGON 97391
DRAWING INDEX AND LIST
OF ABBREVIATIONS
PERMIT SET
DRAWING INDEX
ISSUE LOG
P er m it
S e t
S-001.1 DRAWING INDEX AND LIST OF ABBREVIATIONS X
S-002.1 GENERAL STRUCTURAL NOTES X
S-003.1 GENERAL STRUCTURAL NOTES CONT. X
S-004.1 GENERAL STRUCTURAL NOTES CONT. X
S-005.1 SPECIAL INSPECTIONS AND TESTING X
S-006.1 SPECIAL INSPECTIONS AND TESTING CONT. X
S-132.1 FOUNDATION PLAN X
S-133.1 FLOOR FRAMING PLAN LEVELS 04 AND 05 X
S-136.1 ROOF FRAMING PLAN X
S-301.1 WALL ELEVATIONS X
S-501.1 TYPICAL CONCRETE DETAILS X
S-511.1 TYPICAL MASONRY DETAILS X
S-601.1 TYPICAL STEEL DETAILS X
S-701.1 TYPICAL WOOD DETAILS X
S-702.1 TYPICAL WOOD DETAILS X
S-703.1 TYPICAL WOOD DETAILS X
D A
T E
ISSUE LOG KEY:
' X ' ISSUED AS PART OF A SET
' - ' NOT A PART OF ISSUED SET
' * ' FOR INFORMATION ONLY
/0
/2
GENERAL
STRUCTURAL DRAWINGS ARE A PART OF THE CONTRACT DOCUMENTS AND ARE COMPLEMENTARY TO THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING DRAWINGS, THE SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE REQUIREMENTS FROM THE CONTRACT DOCUMENTS INTO THEIR SHOP DRAWINGS AND WORK. AS REQUIRED BY THE GENERAL
CONDITIONS, THE CONTRACTOR SHALL PROMPTLY REPORT TO THE ARCHITECT ANY ERRORS,
INCONSISTENCIES, OR OMISSIONS IN THE CONTRACT DOCUMENTS DISCOVERED BY OR MADE KNOWN TO THE
CONTRACTOR.
THE GENERAL STRUCTURAL NOTES SUPPLEMENT THE PROJECT SPECIFICATIONS. REFER TO THE PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. NOTES AND DETAILS ON THE STRUCTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER THE GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE GIVEN, CONSTRUCTION SHALL BE AS SHOWN FOR SIMILAR WORK. WHERE CONFLICT EXISTS, THE MORE STRINGENT OR RESTRICTIVE REQUIREMENT SHALL GOVERN UNTIL CLARIFICATION IS REQUESTED.
CODE REQUIREMENTS:
CONFORM TO THE 2025 OREGON STRUCTURAL SPECIALTY CODE (OSSC), BASED ON THE 2024 INTERNATIONAL
BUILDING CODE (IBC).
TEMPORARY CONDITIONS:
THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND/OR SUPPORT THAT MAY BE REQUIRED AS THE RESULT OF THE
CONTRACTOR'S CONSTRUCTION METHODS AND/OR SEQUENCES UNTIL COMPLETION.
CONTRACTOR'S CONSTRUCTION AND/OR ERECTION SEQUENCES SHALL RECOGNIZE AND CONSIDER THE EFFECTS OF THERMAL MOVEMENTS OF STRUCTURAL ELEMENTS DURING THE CONSTRUCTION PERIOD.
EXCAVATIONS SHALL NOT REDUCE THE VERTICAL OR LATERAL SUPPORT FOR ANY FOUNDATION OF THIS PROJECT OR ANY ADJACENT STRUCTURE WITHOUT FIRST UNDERPINNING OR PROTECTING THE FOUNDATION AGAINST DETRIMENTAL LATERAL AND/OR VERTICAL MOVEMENT. REF. SUBMITTALS SECTION FOR
CONTRACTOR'S DELEGATED DESIGN RESPONSIBILITY WHERE SUCH SUPPORT IS REQUIRED.
EXISTING CONDITIONS:
ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS SHALL BE FIELD VERIFIED. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY SIGNIFICANT DISCREPANCIES FROM CONDITIONS SHOWN ON THE DRAWINGS.
ASSUMED FUTURE CONSTRUCTION:
VERTICAL: NONE
HORIZONTAL: NONE
STRUCTURE SUMMARY - TOLEDO HS RENOVATION
EXISTING BUILDING DESCRIPTION
ORIGINAL CONSTRUCTION
CAFETERIA AND BAND ROOM STRUCTURE - 1957 DRAWINGS BY
ANNAND BOONE & LEI ARCHITECTS AND VARIOUS LATER ADJACENT
ADDITIONS
ROOF GRAVITY FRAMING
1x DIAGONAL ROOF SHEATHING OVER 2x10 JOISTS OVER GLULAM
BEAMS SUPPORTED BY REINFORCED CONCRETE PILASTERS
EXISTING LATERAL SYSTEM 8" THICK REINFORCED CONCRETE WALLS
1964 ALTERATION DESCRIPTION BUILDING ADDITION ADDED TO NORTH SIDE OF BAND ROOM.
1996 ALTERATION DESCRIPTION
BUILDING ADDITION ADDED TO WEST SIDE OF BAND ROOM WITH
WOOD FRAMED WALL ADDED TO TOP OF BAND ROOM WEST
CONCRETE WALL.
2014 ALTERATION DESCRIPTION
BUILDING ADDITION ADDED TO SOUTHWEST CORNER OF BAND
ROOM WITH WOOD FRAMED WALL ADDED TO TOP OF BAND ROOM
SOUTH CONCRETE WALL.
STRUCTURAL ALTERATIONS
RISK CATEGORY III
DESIGN BASIS FOR ALTERATIONS
IMPACTING EXISTING GRAVITY FRAMING
ELEMENTS
OSSC 3408.5.2: EXISTING ELEMENTS WITH INCREASE IN DESIGN
LOADS BY MORE THAN 5% AND EXISTING ELEMENTS WITH
REDUCTIONS TO CAPACITY WILL BE STRENGTHENED TO MEET
CURRENT CODE.
PROPOSED ALTERATIONS TO EXISTING
GRAVITY FRAMING ELEMENTS
EXISTING ELEMENTS REVIEWED FOR NEW LOADS LISTED IN DESIGN
CRITERIA SECTION WHERE ALTERATIONS OCCUR. CAPACITY OF
EXISTING FRAMING NOT VERIFIED AT ELEMENTS WITH NO CHANGE IN
DESIGN LOADING OR CAPACITY.
SEISMIC RENOVATION BASIS
THERE IS NO CHANGE IN RISK CATEGORY FROM THE ORIGINAL
CONSTRUCTION. THEREFORE, COMPREHENSIVE SEISMIC
IMPROVEMENTS ARE NOT REQUIRED PER OSSC 3410.6.3. AND
PORTLAND CITY CODE CHAPTER 24.85
DESIGN BASIS FOR ALTERATIONS
IMPACTING EXISTING LATERAL FORCE-
RESISTING ELEMENTS
OSSC 3408.5.3: ALTERATIONS DO NOT INCREASE DEMAND-CAPACITY
RATIO OF EXISTING LATERAL FORCE-RESISTING ELEMENTS BY MORE
THAN 10% EXCEPT AS NOTED BELOW.
PROPOSED ALTERATIONS TO EXISTING
LATERAL FORCE-RESISTING ELEMENTS
NEW SHEATHED ROOF DIAPHRAGM IS PROVIDED OVER THE
CAFETERIA. SOUTH CONCRETE SHEAR WALL IS SHORTENED AND
OPENINGS ADDED. OPENINGS ARE ADDED TO THE GRID 3 CONCRETE
SHEAR WALL FOR THE NEW ELEVATOR.
TARGET BUILDING PERFORMANCE LEVELS
RISK CATEGORY III
SEISMIC RENOVATION BASIS
BASIC PERFORMANCE OBJECTIVE EQUIVALENT TO NEW BUILDING
STANDARDS (BPON) PER ASCE 41-17 TABLE 2-3
ANALYSIS PROCEDURE LINEAR STATIC PROCEDURE (LSP) PER ASCE 41-17 7.4.1.
DESIGN BASIS EARTHQUAKE BSE-1N BSE-2N
TARGET BUILDING PERFORMANCE LEVEL:
STRUCTURAL COMPONENTS DAMAGE CONTROL (S-2) LIMITED SAFETY (S-4)
EXISTING NON-STRUCTURAL COMPONENTS N/A (NON-STRUCTURAL COMPONENTS ARE BEING FULLY REPLACED)
SEISMIC DESIGN CRITERIA
BUILDING PERIOD T = 0.22 s
DESIGN BASIS EARTHQUAKE BSE-1N BSE-2N
RESPONSE SPECTRAL ACCELERATION Sa = 0.941 g Sa = 1.412 g
MODIFICATION FACTORS C1C2 = 1.4 C1C2 = 1.4
MASS PARTICIPATION FACTOR CM = 1.0 CM = 1.0
PSUEDO-LATERAL FORCE 1.32 W 1.98 W
SEISMIC BUILDING WEIGHT (W) 460 KIPS 460 KIPS
PSUEDO-LATERAL BASE SHEAR 607 KIPS 910 KIPS
NEW SEISMIC FORCE-RESISTING SYSTEM (SFRS)
BUILDING PERIOD X DIRECTION ( E / W ) Y DIRECTION ( N / S )
SEICMIC FORCE RESISTING SYSTEM (SFRS)
SPECIAL REINFORCED CONCRETE
MASONRY WALLS, LIGHT-FRAME
WOOD SHEAR WALLS, AND
EXISTING CONCRETE SHEAR
WALLS
LIGHT FRAME WOOD SHEAR
WALLS AND EXISTING CONCRETE
SHEAR WALLS
ALLOWABLE STORY DRIFT RATIO 1.5% (AT BSE-1N) 1.5% (AT BSE-1N)
DESIGN BASIS FOR EXISTING LATERAL
SYSTEM ELEMENTS TO REMAIN
EXISTING CONCRETE SHEAR WALLS AND THEIR FOUNDATIONS ARE
EVALUATED FOR ANY ADDITIONAL LOADING AND/OR REDUCED
CAPACITY PER ASCE 41-17.
THE SEISMIC FORCE-RESISTING SYSTEM (SFRS) FOR THE COMPLETED STRUCTURE IS AS FOLLOWS:
CONCRETE SHEAR WALLS ON GRIDS 1, 3, 4.5, E, AND H. NEW CMU SHEAR WALL ON GRID H. NEW ROOF DIAPHRAGMS. LIGHT-FRAME WOOD SHEAR WALLS ALONG THE NORTH AND SOUTH SIDES OF THE NEW WOOD-
FRAMED CORRIDORS.
REFER TO THE GENERAL STRUCTURAL NOTES AND SPECIFICATIONS FOR ADDITIONAL FABRICATING, INSTALLATION, TESTING AND INSPECTION REQUIREMENTS FOR MEMBERS THAT ARE PART OF THE SFRS.
DESIGN CRITERIA
DESIGN WAS BASED ON THE STRENGTH AND DEFLECTION CRITERIA OF THE OSSC. IN ADDITION TO THE DEAD LOADS, THE FOLLOWING LOADS AND ALLOWABLES WERE USED FOR DESIGN, WITH LIVE LOADS (L.L.) REDUCED
PER OSSC:
GRAVITY SYSTEM CRITERIA
OCCUPANCY OR USE UNIFORM LOAD CONCENTRATED LOAD
CORRIDORS 100 PSF L.L. 1,000 LBS.
ASSEMBLY AREAS 100 PSF L.L. 1,000 LBS.
ROOF LIVE/SNOW LOAD 25 PSF SNOW LOAD (ALSO SEE SNOW LOAD CRITERIA BELOW)
GRAVITY LOADING NOTES:
1. LIVE LOADS REDUCED PER OSSC.
2. MEMBERS DESIGNED FOR MORE CRITICAL OF UNIFORM OR
CONCENTRATED LOAD.
FRAMING MEMBER DEFLECTION LIMITS
VERTICAL FLOOR FRAMING
DEFLECTION - BUILDING INTERIOR
l/360 DUE TO L.L. AND l/240 DUE TO L.L. PLUS LONG TERM CREEP COMPONENT OF D.L.
VERTICAL ROOF FRAMING
DEFLECTION - BUILDING INTERIOR
l/240 DUE TO SNOW LOAD AND l/180 DUE TO SNOW LOAD PLUS LONG TERM CREEP COMPONENT OF D.L.
HORIZONTAL DEFLECTION -
EXTERIOR WALL FRAMING
l/240 DUE TO ASD WIND LOAD
DEFLECTION LIMIT NOTES:
1. l = LENGTH OF STRUCTURAL FRAMING MEMBER BETWEEN SUPPORTS.
2. FOR CANTILEVER FRAMING, l SHALL BE TAKEN AS 2X THE CANTILEVER
LENGTH.
3. LONG TERM CREEP COMPONENT OF DEAD LOAD (D.L.) INCLUDES ONLY
THE TIME DEPENDENT PORTION OF LONG TERM DEAD LOADING AND IS
APPLICABLE TO CONCRETE AND WOOD FRAMING ONLY.
SNOW CRITERIA
DESIGN ROOF SNOW LOAD 37.2 PSF MINIMUM IN ACCORDANCE WITH OSSC
WINTER WIND PARAMETER 0.35
SNOW DRIFT PER OSSC AS SHOWN ON PLANS
GROUND SNOW LOAD Pg= 35 PSF
FLAT ROOF SNOW LOAD Pf = 29.2 PSF
SNOW EXPOSURE FACTOR Ce = 1.0
THERMAL FACTOR Ct = 1.19
GEOTECHNICAL CRITERIA
DESIGN BASED ON REPORT BY: CARLSON GEOTECHNICAL, DATED NOVEMBER 14, 2025
ASSUMED DELEGATED DESIGN HELICAL PILE CAPACITIES (TO BE VERIFIED BY DELEGATED DESIGN ENGINEER):
DOWNWARD 20 TONS
UPWARD 20 TONS
SHORT TERM LOADING 1/3 INCREASE
WIND CRITERIA
RISK CATEGORY III
BASIC WIND SPEED VULT = 130 MPH (3-SECOND GUST) VASD = 101 MPH (3-SECOND GUST)
EXPOSURE CATEGORY B
GUST / INTERNAL PRESSURE GCpi = +/- 0.18
RAIN-ON-SNOW SURCHARGE 8 PSF
STRUCTURAL OBSERVATIONS
THE STRUCTURAL ENGINEER OF RECORD (SEOR) WILL PERFORM STRUCTURAL OBSERVATIONS BASED ON THE REQUIREMENTS OF THE OSSC AT THE STAGES OF CONSTRUCTION LISTED BELOW. CONTRACTOR SHALL PROVIDE SUFFICIENT ADVANCED NOTICE AND ACCESS FOR THE SEOR TO PERFORM THESE OBSERVATIONS.
ITEM COMMENTS
PRIOR TO FIRST CONCRETE POUR AFTER REBAR PLACEMENT
DURING INITIAL WOOD FRAMING CONSTRUCTION
AS REQUIRED TO ADDRESS STRUCTURAL ISSUES
A FIELD REPORT WILL BE SUBMITTED TO THE BUILDING DEPARTMENT FOLLOWING EACH SITE VISIT.
STRUCTURAL OBSERVATION IS FOR THE GENERAL CONFORMANCE OF THE STRUCTURAL DRAWINGS AND DOES
NOT ALLEVIATE ANY SPECIAL INSPECTION REQUIREMENTS.
SPECIAL INSPECTIONS AND TESTING
SPECIAL INSPECTION WILL BE PROVIDED BY THE OWNER BASED ON THE REQUIREMENTS OF THE OSSC AS SUMMARIZED IN THE SPECIAL INSPECTION AND TESTING PROGRAM ON SHEETS S00X-S00X. CONTRACTOR SHALL PROVIDE SUFFICIENT NOTICE AND ACCESS FOR THE SPECIAL INSPECTOR TO PERFORM THESE INSPECTIONS.
SUBMITTALS
SUBMIT SHOP DRAWINGS AND OTHER SUBMITTALS TO THE ARCHITECT AND ENGINEER PRIOR TO FABRICATION AND CONSTRUCTION OF STRUCTURAL ITEMS. IF THE SUBMITTALS DIFFER FROM OR ADD TO THE STRUCTURAL CONTRACT DOCUMENTS, THEY SHALL BEAR THE SEAL AND SIGNATURE OF A STRUCTURAL ENGINEER REGISTERED IN THE STATE OF OREGON. ANY CHANGES TO THE STRUCTURAL DRAWINGS SHALL BE SUBMITTED TO THE
ARCHITECT AND ARE SUBJECT TO REVIEW AND ACCEPTANCE BY THE SEOR.
FIELD ENGINEERED DETAILS DEVELOPED BY THE CONTRACTOR THAT DIFFER FROM OR ADD TO THE STRUCTURAL DRAWINGS SHALL BEAR THE SEAL AND SIGNATURE OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF
OREGON AND SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO CONSTRUCTION.
THE USE OF REPRODUCTIONS OR PHOTOCOPIES OF THE CONTRACT DRAWINGS SHALL NOT BE PERMITTED. WHEN CAD OR REVIT FILES ARE PROVIDED TO THE CONTRACTOR OR SUBCONTRACTORS, IT IS THE RESPONSIBILITY OF THE CONTRACTOR/SUBCONTRACTOR TO REMOVE ALL INFORMATION NOT DIRECTLY RELEVANT TO THE SCOPE OF THE
SUBMITTAL AS WELL AS ALL REFERENCES TO OUTSIDE SOURCE FILES.
DELEGATED DESIGN SUBMITTALS SHALL INCLUDE DESIGN DRAWINGS AND CALCULATIONS FOR ITEMS THAT ARE DESIGNED BY OTHERS. DELEGATED DESIGN SUBMITTALS SHALL BEAR THE SEAL AND SIGNATURE OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF OREGON ON EVERY DRAWING SHEET AND ON THE CALCULATION COVER SHEET, AND SHALL BE SUBMITTED TO THE ARCHITECT AND ENGINEER PRIOR TO FABRICATION.
CALCULATIONS AND DETAILS SHALL BE INCLUDED FOR ALL CONNECTIONS TO THE STRUCTURE, CONSIDERING LOCALIZED EFFECTS ON STRUCTURAL ELEMENTS. DESIGN SHALL BE BASED ON THE REQUIREMENTS OF THE OSSC
AND AS NOTED UNDER "DESIGN CRITERIA".
SUBMITTALS AND DELEGATED DESIGN SUBMITTALS SHALL INCLUDE THE FOLLOWING:
ITEM SUBMITTAL
DELEGATED
DESIGN
SUBMITTAL
COMMENTS
MEPF SYSTEMS ANCHORAGE AND BRACING X REF. TABLE NOTE 1
HELICAL PILES X
FOUNDATION EXCAVATION AND UNDERPINNING X REF. TABLE NOTE 2
CONCRETE MIX DESIGNS X
CONCRETE REINFORCEMENT X
A706 REBAR SUBSTITUTION MILL CERTIFICATIONS X
MASONRY REINFORCEMENT X
CONCRETE ANCHORAGES X
EMBEDDED STEEL ITEMS X
CONSTRUCTION JOINT LAYOUT X
STRUCTURAL STEEL X
STEEL WELDING PROCEDURES X
STEEL FASTENERS X
GLUE-LAMINATED MEMBERS X
ENGINEERED WOOD I-JOISTS X
PENETRATIONS OF SLABS/DECKS, WALLS, ETC. X
ROOF TIE-OFF ANCHORS X
TABLE NOTES:
1. THE CONTRACTOR SHALL COORDINATE SEISMIC RESTRAINTS OF MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SAFETY EQUIPMENT AND ASSOCIATED DISTRIBUTION SYSTEMS WITH THE STRUCTURE. CONNECTIONS TO STRUCTURE AND PROVISIONS FOR SEISMIC MOVEMENTS SHALL CONFORM TO ASCE 7-22 CHAPTER 13, BE DESIGNED BY AN ENGINEER REGISTERED IN THE STATE OF OREGON, AND SHALL BE SUBMITTED TO THE ARCHITECT AND SEOR PRIOR TO FABRICATION. FOR RISK CATEGORY III AND IV BUILDINGS, THE SYSTEMS ENGINEER SHALL SPECIFY THE REQUIREMENTS FOR EQUIPMENT SEISMIC CERTIFICATION IN THE DEFERRED SUBMITTAL IN ACCORDANCE WITH OSSC SECTION 1705.13.4 AND ASCE 7-22 SECTION 13.2.2.
2. CONTRACTOR SHALL ENGAGE A PROFESSIONAL ENGINEER TO PREPARE AN ASSESSMENT OF ANY EXCAVATIONS THAT MAY REDUCE THE VERTICAL OR LATERAL SUPPORT OF AN EXISTING FOUNDATION AS REQUIRED BY OSSC SECTION 1803.5.7. THE ASSESSMENT SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT AND SHALL INCLUDE DETAILS AND SEQUENCING FOR CONSTRUCTION OF ANY UNDERPINNING OR BRACING
THAT IS REQUIRED.
SEISMIC DESIGN CRITERIA FOR NEW DELEGATED DESIGN
AND NON-STRUCTURAL ITEMS
DESIGN CODE ASCE 7-22
RISK CATEGORY III
DESIGN SPECTRAL RESPONSE SDS = 1.43
BUILDING PERIOD Ta = 0.22
STRUCTURE DUCTILITY FACTOR
Rμ = 1.3 (FOR ABOVE GRADE COMPONENTS
Rμ = 1.0 (FOR COMPONENTS AT GRADE AND BELOW)
EXISTING MATERIAL PROPERTIES - TOLEDO HS RENOVATION
BUILDING COMPONENT
EXPECTED MATERIAL
STRENGTH, kQCE
SPECIFIED (LOWER
BOUND) MATERIAL
STRENGTH, kQCL
ASCE 41-17
KNOWLEDGE FACTOR,
k
CONCRETE COMPONENTS (PSI)
CAST-IN-PLACE WALLS AND PILASTERS 2,813 1,875 0.75
CAST-IN-PLACE FOUNDATIONS 2,813 1,875 0.75
STEEL COMPONENTS (PSI)
CONCRETE REINFORCEMENT 30,938 24,750 0.75
STEEL PLATES 39,600 36,000 1.00
WOOD GRADING
DOUGLAS FIR S-DRY - SELECT STRUCTURAL - TYPICAL U.N.O.
NOTES:
1. SPECIFIED (LOWER BOUND) MATERIAL STRENGTH MAY BE USED FOR ASCE 7-22 DESIGN OF NEW ELEMENT
CONNECTIONS TO EXISTING MATERIALS.
N
79476PE
13, OREGON
EXPIRES
MAR.
NE
G I
S T R U C T
702 0
REE
RU LA
R I C H A RD S
P.AUHSOJ
PROFESS I ONA L
DERETSI
GER
111 SW Fifth Ave., Suite 2600
Portland, OR 97204
O: 503.227.3251
F: 503.227.7980 www.kpff.com
ARCHITECTS
CONSULTANT
STAMP
REVISION NO. DATE
KEY PLAN - (NTS)
SHEET NUMBER
DRAWING TITLE
SCALE
DATE
PROJECT NUMBER
ISSUANCE
TRUE
NORTH
PLAN
NORTH
10022500757 R-24
12-13-26
12" = 1'-0"
/1
/2
:0
:3
P
M
A u to d e s k D o c s /1
L C
S D
T o le d o
H S
A u d it o ri u m
/1
R
-2 .r v t
S-002.1
6/1/2026
25035
TOLEDO HIGH
SCHOOL
AUDITORIUM
LINCOLN COUNTY SCHOOL DISTRICT
1800 N.E. STURDEVANT RD.
TOLEDO, OREGON 97391
GENERAL STRUCTURAL
NOTES
GENERAL STRUCTURAL NOTES
CONCRETE REINFORCING STEEL
CONCRETE REINFORCEMENT SHALL BE AS LISTED BELOW. ASTM A615 REINFORCEMENT MAY BE SUBSTITUTED FOR ASTM A706 REINFORCEMENT PROVIDED THAT THE ACTUAL YIELD STRENGTH BASED ON MILL TESTS DOES NOT EXCEED Fy BY MORE THAN 18,000 PSI AND THE RATIO OF ACTUAL TENSILE STRENGTH TO ACTUAL YIELD STRENGTH IS NOT LESS THAN 1.25 AND THE ELONGATION REQUIREMENTS OF ASTM A706 ARE MET PER ACI 318-19 SECTION
20.2.2.5. MILL TESTS CERTIFICATIONS FOR SUBSTITUTED BARS SHALL BE SUBMITTED TO THE SPECIAL INSPECTOR AND SEOR PRIOR TO PLACEMENT. ASTM A706 REINFORCEMENT MAY BE SUBSTITUTED FOR ASTM A615
REINFORCEMENT.
REINFORCING LOCATION MATERIAL GRADE
REINFORCING TO BE WELDED ASTM A706 GRADE 60
ALL OTHER USES U.N.O. ASTM A615 GRADE 60
ALL REINFORCING STEEL SHALL BE SECURELY TIED IN PLACE WITH #16 ANNEALED IRON WIRE. BARS IN BEAMS AND SLABS SHALL BE SUPPORTED ON WELL-CURED CONCRETE BLOCKS OR APPROVED METAL OR PLASTIC CHAIRS, AS SPECIFIED BY THE CRSI MANUAL OF STANDARD PRACTICE, MSP-1. REINFORCING STEEL SHALL BE DETAILED IN ACCORDANCE WITH ACI MNL-66 "ACI DETAILING MANUAL". SHOP DRAWINGS SHALL INCLUDE ELEVATIONS OF ALL
BEAMS, WALLS AND COLUMNS SHOWING BAR LOCATIONS.
REINFORCING BARS SHALL NOT BE BENT OR STRAIGHTENED IN THE FIELD WITHOUT APPROVAL OF THE SEOR.
PREHEATING METHODS SHALL BE SUBMITTED TO THE SEOR FOR APPROVAL PRIOR TO BENDING OF BARS #6 OR
LARGER.
LAP ALL REINFORCING BARS PER THE TYPICAL LAP SPLICE LENGTH SCHEDULES, EXCEPT AS NOTED ON DRAWINGS.
USE LAP LENGTH FOR SMALLER BAR WHEN SPLICING DIFFERENT BAR SIZES. BARS SPLICED WITH NONCONTACT LAPS SHALL BE SPACED NO FARTHER THAN 1/5TH THE LAP LENGTH OR 6 INCHES. MECHANICAL SPLICES NOTED ON THE PLANS SHALL BE DAYTON SUPERIOR BAR-LOCK OR TAPER-LOCK COUPLERS (UES ER-319) OR APPROVED EQUAL WITH A CURRENT EVALUATION REPORT. FOR CONCRETE STRENGTHS BETWEEN TABULATED VALUES, USE LAP
SPLICE LENGTHS FOR NEAREST LOWER CONCRETE STRENGTH INDICATED.
TYP. WALL AND SLAB LAP SPLICE LENGTH SCHEDULE (IN.) - 60 KSI
BAR
SIZE
WALL VERTICAL AND SLAB BOTTOM BARS WALL HORIZONTAL AND SLAB TOP BARS
3,000
PSI
4,000
PSI
5,000
PSI
6,000
PSI
7,000
PSI
≥ 8,000
PSI
3,000
PSI
4,000
PSI
5,000
PSI
6,000
PSI
7,000
PSI
≥ 8,000
PSI
#3 18 16 16 16 16 16 24 20 18 18 16 16
#4 30 26 24 22 20 18 38 34 30 28 26 24
#5 36 32 28 26 24 22 48 42 36 34 32 30
#6 44 38 34 32 28 28 56 50 44 40 38 36
#7 70 60 54 50 46 44 90 78 70 64 60 56
#8 86 74 68 62 56 54 112 98 88 80 74 70
#9 104 90 82 74 68 64 136 118 106 96 90 84
#10 126 108 98 88 82 78 162 142 126 116 106 100
#11 146 128 114 104 96 90 190 166 148 136 126 118
TYP. FOUNDATION AND MAT LAP SPLICE LENGTH SCHEDULE (IN.) - 60 KSI
BAR
SIZE
BOTTOM BARS TOP BARS
3,000
PSI
4,000
PSI
5,000
PSI
6,000
PSI
7,000
PSI
8,000
PSI
3,000
PSI
4,000
PSI
5,000
PSI
6,000
PSI
7,000
PSI
≥ 8,000
PSI
#3 18 14 14 12 12 12 22 20 18 16 14 14
#4 22 20 18 16 14 14 28 26 22 20 20 18
#5 28 24 22 20 18 18 36 32 28 26 24 22
#6 34 28 26 24 22 22 42 38 34 30 28 28
#7 48 42 38 34 32 30 62 54 48 44 42 38
#8 54 48 42 38 36 34 70 62 54 50 46 44
#9 62 54 48 44 40 38 80 70 62 58 52 50
#10 70 60 54 50 46 42 90 78 70 64 60 56
#11 80 70 64 58 54 50 104 90 82 74 68 64
TABLE NOTES:
1. SPLICE LENGTHS APPLY TO ASTM A615 OR ASTM A706 GRADE 60 DEFORMED REINFORCING BARS ONLY.
2. SPLICE LENGTHS ARE BASED ON THE CLEAR COVER AND MINIMUM BAR CLEAR SPACING…